ohm and current meter milli-to 3products.coesfeld.com/.../200-233_milli-to_3_e.pdf · milli-to3...

3
Ohm and Current Meter Milli-TO 3 4 4 4 4 4 4 4 4 4 4 4 4 4 4 resistance range from 1,8 x 10 to 1,6 x 10 Ohm current range from 0,1 pA to 1,1 mA autoranging or manual ranging easy handling by predefined buttons variable test voltage from 1 to 500 V limit indication by relay and beeper compensation of thermo voltage in low ohm range zero control variable timer from 10 to 300 sec RS 232 interface measurement rate: approx. 1 per sec 2 LCD displays dimensions: 340 x 150 x 300 mm weight: 5,5 kg -6 15 The high-precision instrument is a refinement of the Milli-TO2, which was manufactured and sold with great success for over 20 years. The Milli-TO 3 identifies resistance values up to 1,6 PetaOhm full scale easily and reliable. To handle the instrument you can choose between an internal menu or a PC-GUI. The Milli-TO3 provides a programmable and remote-controlled interface which also allows processing all measured data. The measured values are displayed in scientific form with 2½ to 4 digits. You can choose between 3 predefined test voltages of 10 V, 100 V or 500 V or a variable voltage range, programmable from 1 V to 500 V in 1 V steps. The test voltage source has a low capacitance and the max. test current is <3 mA. ½ Accessories: wide range of electrodes measurement cables resistors for calibration Milli-TO 3 with optional electrode HOW 3 Milli-TO 3 with optional electrode EH 15/20 for measurement of volume, surface, bleeder resistance, small currents and cable resistance

Upload: others

Post on 22-May-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Ohm and Current Meter Milli-TO 3products.coesfeld.com/.../200-233_Milli-TO_3_E.pdf · Milli-TO3 provides a programmable and remote-controlled interface which also allows processing

Ohm and Current Meter

Milli-TO 3

4

4

4

4

4

4

4

4

4

4

4

4

4

4

resistance range from 1,8 x 10 to 1,6 x 10 Ohm

current range from 0,1 pA to 1,1 mA

autoranging or manual ranging

easy handling by predefined buttons

variable test voltage from 1 to 500 V

limit indication by relay and beeper

compensation of thermo voltage in low ohm range

zero control

variable timer from 10 to 300 sec

RS 232 interface

measurement rate: approx. 1 per sec

2 LCD displays

dimensions: 340 x 150 x 300 mm

weight: 5,5 kg

-6 15

The high-precision instrument is a refinementof the Milli-TO2, which was manufactured andsold with great success for over 20 years.

The Milli-TO 3 identifies resistance values upto 1,6 PetaOhm full scale easily and reliable.

To handle the instrument you can choosebetween an internal menu or a PC-GUI. TheMilli-TO3 provides a programmable andremote-controlled interface which also allowsprocessing all measured data.

The measured values are displayed inscientific form with 2½ to 4 digits.

You can choose between 3 predefined testvoltages of 10 V, 100 V or 500 V or a variablevoltage range, programmable from 1 V to500 V in 1 V steps.

The test voltage source has a low capacitanceand the max. test current is <3 mA.

½

Accessories:wide range of electrodesmeasurement cablesresistors for calibration

Milli-TO 3 with optional electrode HOW 3

Milli-TO 3 with optional electrode EH 15/20

for measurement of volume, surface, bleeder resistance, small currentsand cable resistance

E-Mail: [email protected]: www.coesfeld.com

Coesfeld GmbH & Co. KGTronjestraße 8 * 44319 Dortmund

Telefon: +49 231 912 980 0Telefax: +49 231 179 885

Page 2: Ohm and Current Meter Milli-TO 3products.coesfeld.com/.../200-233_Milli-TO_3_E.pdf · Milli-TO3 provides a programmable and remote-controlled interface which also allows processing

Ohm and Current Meter

Milli-TO 3Technical Specifications

General Data

Measuring: control via START-/STOP-button,timer or through RS232-interface /remote start

Reading rate: approx. 1 reading per second withinsame range

Ranges: 7 ranges, auto ranging or manualranging

Function: controlled by buttons, RS232interface or remote at rear side

Response time: to rated accuracy 10 minutes

Displays: 2 LCD´s with 2 rows by 20 digitseachrange display in scientific form(e.g. 16,55 E9 for 16,55 GOhm)LED´s to indicate V ON! and

FAULTLED´s in all buttons

Indications: limit indication by relay contact(max. 24 V/ 0,5 A) and beeper foroverrun or underrun ofprogrammable limit window;overflow or underflow indicated indisplay as OVERRANGE orUNDERRANGE and send viaRS232

Power Supply: 230 V AC, 50 Hz(190 V AC - 260 V AC)approx. 20 VA

Fuses: main fuse in Euro-socket 1,6 AT;Rx-Low fuse at the rear side 1,6 AT;fuse in the switching power supply2 AT (qualified technician required)

Connectors: for LIMIT, GND and earth pole4 mm panel jack at the rear sideSUB-D 9 pole for remote

Safety class:

Protective System: Schutzart IP 40 (Germany)

Temperature: operating: 15°C - 23 - 35°C

storage: -10°C to +60°C

Size: W/H/L 340 x 150 x 300 mm

Weight: 5,5 kg

M

Schutzklasse 1 (Germany)

°C

Humidity: max. 70 %,no condensation allowed!

Housing: desktop case with metal hand grip

Ix (Current Measurement)

Measuring Range: 0,1 x 10 A to 1,1 x 10 A

Display: 3½ (0,0 to 1,100)

Ranges: 7; full auto ranging ormanual ranging

Accuracy at 23°C +/- 1 K:

Temperature Coefficient ( 15 to 35°C):+/- 0,02 % / K

DC Input Resistance of the Current Circuit (R):

2: 10,1 k

Over Voltage Protection: +/- 10 VDC

Over Current Protection: +/- 10 mADC

-12 -3

digit

range 1 to 5: +/- 0,2 % +2 digitrange 6: +/- 0,5 % +2 digitrange 7: +/- 1 % +2 digit

range 1: 200 bzw. 1,1 krangerange 3: 100 krange 4: 1 Mrange 5: 10 Mrange 6: 100 Mrange 7: 1 G

i

Ù Ù

ÙÙ

ÙÙ

Ù

Ù

E-Mail: [email protected]: www.coesfeld.com

Coesfeld GmbH & Co. KGTronjestraße 8 * 44319 Dortmund

Telefon: +49 231 912 980 0Telefax: +49 231 179 885

Page 3: Ohm and Current Meter Milli-TO 3products.coesfeld.com/.../200-233_Milli-TO_3_E.pdf · Milli-TO3 provides a programmable and remote-controlled interface which also allows processing

High-Ohm (High Resitance Measurement)

Measuring range:

- at measurement voltage1 V: 0,9 x 10 to 3,3 x 10

10 V: 9 x 10 to 33 x 10100 V: 90 x 10 to 0,33 x 10500 V: 450 x10 to 1,6 x 10

up to 2 x10 detectable

Ranges: 7; full auto ranging ormanual ranging

Accuracy at 23 °C +/- 1 K within 12 months:range 1 to 5: +/- 0,3% +2 digitsrange 6: +/- 0,5% +2 digitsrange 7: +/- 1% +2 digits

Temperature coefficient: 15 °C to 35 °C: +/-0,1% / K

Test Voltage OFF: EUT deloads over 10 k

to GND

Overvoltage at V OFF: +/- 100 VDC

R / I connectors: c

3 12

3 12

3 15

3 15

15

ÙÙ

ÙÙ

- through current measurement

Ù

Test voltage: 10 V, 100 V, 500 Vor variable 1 V bis 500 V in1 V steps

Accuracy of Test Voltage: at 23 °C: +/- 0,2 %

Temperature coefficientof Test Voltage: +/- 0,01 % / K

Test Current: max. 3 mA at 10 kload resistance

Test Voltage Source: continious short-circuitallowed

Overvoltage protection at:V 10 V: 20 VDC

V 100 V: 200 VDC

V 500 V: 750 VDC

var. V 1 V to 500 V: 2 xV , max. 750 VDC

V

oax jack 4 mm/13 mm

(DIN 47284)

Ù

M

M

M

M M

M

M

x x

Ohm and Current Meter

Milli-TO 3Technical Specifications

Low-Ohm (Low Resistance Measurement)

Measuring Range: 180 m to 180 k

Resolution at 4½-digit Display: range 1: 10range 7: 10

Test current: range 1: 1,0 Arange 7: 1,0 A

Display: 2½-digit, 3½-digit, 4½-digit programmable

Method of Measuring: 2- or 4-terminal method(Kelvin method)decade constantcurrent

Compensation and Controlling of Thermo-Voltage:0 to +/- 20 mV allowed

Accuracy at 23 °C +/- 1K: +/- 0,2% of input+/- 2 digit(typically 0,1%)

Temperature coefficient (15 to 30 °C):+/- 0,1% / K

Max. Voltage over EUT: < 4 VDC

Max. External Voltage between Source Clamps:-24 VDC and +3 VDC

Ù Ù

ìÙÙ

ì

Max. External Voltage between Sense Clamps:+/- 48 VDC

R connectors: 4 x 4 mm jack or 5 polDIN connector

Fuse in the low-ohm circuit: 1,6 A MT at therear side

X

E-Mail: [email protected]: www.coesfeld.com

Coesfeld GmbH & Co. KGTronjestraße 8 * 44319 Dortmund

Telefon: +49 231 912 980 0Telefax: +49 231 179 885