open ended lab methodology
DESCRIPTION
pvdf membrane glycerolTRANSCRIPT
![Page 1: Open Ended Lab Methodology](https://reader036.vdocument.in/reader036/viewer/2022082411/563db7dd550346aa9a8eb4a2/html5/thumbnails/1.jpg)
1
Methodology of the fabrication of Glycerol coated Polyvinylidene
Fluoride (PVDF) Membranes
Group Members:
1. Kelvin Ho Pau Hui
2. Gong Wee Jie
3. Mohammed Hussain
4. Yugaraj Balar
5. Muhammad Asfand Yar
![Page 2: Open Ended Lab Methodology](https://reader036.vdocument.in/reader036/viewer/2022082411/563db7dd550346aa9a8eb4a2/html5/thumbnails/2.jpg)
2
Methodology
Coating / Dip Coating
1. Immersion – Substrate is immersed in a solution containing 70 wt% glycerol, 0.2-1.5% cellulosic polymer and 1-3% cross-linking agents at a constant speed (preferably jitter-free)
2. Start-Up – Substrate has remained inside the solution for a while and is starting to be pulled up.
3. Deposition – The thin layer deposits itself on the substrate while it is pulled up. Withdrawing is carried out.
4. Drainage – Excess liquid will drain from the surface.5. Evaporation – The solvent evaporates from the liquid, forming
thin layers.
![Page 3: Open Ended Lab Methodology](https://reader036.vdocument.in/reader036/viewer/2022082411/563db7dd550346aa9a8eb4a2/html5/thumbnails/3.jpg)
3
Change in Properties
Porosity
• Increases initially with increasing glycerol concentration until a certain point where it starts to decrease.
• Volume of pores divided by total volume of porous membrane or;
![Page 4: Open Ended Lab Methodology](https://reader036.vdocument.in/reader036/viewer/2022082411/563db7dd550346aa9a8eb4a2/html5/thumbnails/4.jpg)
4
Shrinkage
• Increase in hydrophilicity decreases shrinkage ratio
• High shrinkage ratio decreases pore size
• Percentage of shrinkage can be calculated using a micrometer
![Page 5: Open Ended Lab Methodology](https://reader036.vdocument.in/reader036/viewer/2022082411/563db7dd550346aa9a8eb4a2/html5/thumbnails/5.jpg)
5
Membrane Thickness
• Flux decreases with increasing thickness
• Increase of transmembrane resistance
• Thick membrane increases mechanical strength (tensile strength and bursting pressure)
![Page 6: Open Ended Lab Methodology](https://reader036.vdocument.in/reader036/viewer/2022082411/563db7dd550346aa9a8eb4a2/html5/thumbnails/6.jpg)
6
Contact Angle
• Hydrophobic surfaces have higher contact angle than hydrophilic
• Membranes with higher concentration of glycerol have lower contact angle
• Measured using a goniometer
![Page 7: Open Ended Lab Methodology](https://reader036.vdocument.in/reader036/viewer/2022082411/563db7dd550346aa9a8eb4a2/html5/thumbnails/7.jpg)
7
![Page 8: Open Ended Lab Methodology](https://reader036.vdocument.in/reader036/viewer/2022082411/563db7dd550346aa9a8eb4a2/html5/thumbnails/8.jpg)
8
References
1. Mulder, M. (1992) “Basic Principle of Membrane Technology”, Dordrecht: Kluer Academic Publishers.
2. Hilal, N., Khayet, M. and Chris J. Wright (2012) “Membrane Modification: Technology and Applications”, USA: CRC Press.