operational experience under icing conditions of repower mm-cold-climate-version turbines under the...

8
Operational experience of REpower MM-CCV under icing conditions REpower Systems Northern Europe Winterwind 2012, Skellefteå

Upload: winterwind

Post on 11-Nov-2014

903 views

Category:

Business


0 download

DESCRIPTION

 

TRANSCRIPT

Page 1: Operational experience under icing conditions of REpower MM-Cold-Climate-Version turbines under the influence of different icing solutions Kurt Stürken, REpower

Operational experience of REpower

MM-CCV under icing conditions

REpower Systems Northern Europe

Winterwind 2012, Skellefteå

Page 2: Operational experience under icing conditions of REpower MM-Cold-Climate-Version turbines under the influence of different icing solutions Kurt Stürken, REpower

2

REpower company profile

Northern Europe

Västerås

ÅrhusKristianstad

Helsinki

SWEDEN

NORWAY

FINLAND

DENMARK

ESTONIA

LATVIA

LITHUANIA

Hamburg

3 x MM923 x MM92

REpower Systems Scandinavia ABREpower Systems Scandinavia AB

Office located in Västerås

� Sales

� Project Management

� Engineering Support

Service Center #1 in Kristianstad

Office located in Västerås

� Sales

� Project Management

� Engineering Support

Service Center #1 in Kristianstad

Projects commissioned in 2011Projects commissioned in 2011

Subsidiary present in Sweden since September 2010.

Page 3: Operational experience under icing conditions of REpower MM-Cold-Climate-Version turbines under the influence of different icing solutions Kurt Stürken, REpower

3

REpower Cold Climates

Operational experience

Inner Mongolia, ChinaInner Mongolia, China

Installation in 2007Installation in 2007

Quebec Region, CanadaQuebec Region, Canada

Installation in 2009Installation in 2009

Erzgebirge, Czech RepublicErzgebirge, Czech Republic

Installation in 2008Installation in 2008

Alaska, USAAlaska, USA

Installation in 2012Installation in 2012

� Severe icing conditions / Long winter periods

� CCV turbine adapted to cold climate

� Equipped with various icing solutions

� Validation in cooperation e.g. with local research institutes

� Severe icing conditions / Long winter periods

� CCV turbine adapted to cold climate

� Equipped with various icing solutions

� Validation in cooperation e.g. with local research institutes

500 CCV turbines will be installed until 2015500 CCV turbines will be installed until 2015

Page 4: Operational experience under icing conditions of REpower MM-Cold-Climate-Version turbines under the influence of different icing solutions Kurt Stürken, REpower

4

Project specific site analysisProject specific site analysisTurbine stopTurbine stop

Residential areas:

High impact of ice throw

Residential areas:

High impact of ice throw

� Immediate & reliable turbine stop in case of ice detection

� Reliable restart after ice melting

De-Icing will not avoid ice throw completely

De-Icing will not avoid ice throw completely

REpower solution assessed by third party

REpower solution assessed by third party

Operation under icing conditions

Residential areas

Page 5: Operational experience under icing conditions of REpower MM-Cold-Climate-Version turbines under the influence of different icing solutions Kurt Stürken, REpower

5

Project specific site analysisProject specific site analysis Keep turbine

operating

Keep turbine

operating

Remote areas:

Low impact of ice throw

Remote areas:

Low impact of ice throw

Operation under icing conditions

Remote areas

� Load and vibration management by REpower smart control algorithm

� Rugged aerodynamic design for high performance (even with iced blades)

REpower turbines designed to operate efficiently with iced

blades

REpower turbines designed to operate efficiently with iced

blades

Page 6: Operational experience under icing conditions of REpower MM-Cold-Climate-Version turbines under the influence of different icing solutions Kurt Stürken, REpower

6

Operation under icing conditions

Optional icing solutions

Site specific determination of best solution packageSite specific determination of best solution package

� De-icing / Anti-icing to further increase efficiency at severe icing conditions

� Different de-icing and anti-icing systems implemented worldwide

� Validation process ongoing to decide for solutions

- Low lifecycle costs- Efficiency- Reliability- Ability to retrofit

Page 7: Operational experience under icing conditions of REpower MM-Cold-Climate-Version turbines under the influence of different icing solutions Kurt Stürken, REpower

7

Operation under icing conditions

Summary

� REpower has long year experience in cold climates with high turbine availability

� REpower turbines allow safe and economic operation under icing conditions

� REpower support your projects with site specific ice assessments and tailored icing solutions

Page 8: Operational experience under icing conditions of REpower MM-Cold-Climate-Version turbines under the influence of different icing solutions Kurt Stürken, REpower

8

© REpower Systems SE

All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photography, recording, or any information storage and retrieval system, without permission from REpower Systems AG.

Your contacts:

REpower Systems SE

Lea Kirsch

Productmanager WEC Equipment

[email protected]

REpower Systems Scandinavia AB

Niclas Erkenstǻl

Head of Sales Sweden

[email protected]