page 1/1 dry installed chopperpump

46
Page 1/1 Content last updated on 25. February 2021 The text and technical data given must not be reproduced partly or completely without permission from Landia A/S. We reserve the right to make technical alterations. Conversion table Oil table Oil-/Conversion table Quickguede Service instruction Technical data sheet Principal measurements Schematic drawing MPTK-I and MPTKR-I Table of contents Please click on the links below "table of contents" to get the information needed. drawing, service instructions and more. Here you will find technical documentation for Landia Chopperpump in the form of schematic Dry installed Chopperpump HP 400 US landiainc.com Elektric data 460V-60 Hz IE2 Elektric data 460V-60 Hz IE1 Elektric data

Upload: others

Post on 18-Oct-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Page 1/1 Dry installed Chopperpump

Page 1/1

Content last updated on 25. February 2021

The text and technical data given must not be reproduced partly or completely without permission from Landia A/S. We reserve the right to make technical alterations.

Conversion table

Oil table

Oil-/Conversion table

Quickguede

Service instruction

Technical data sheet

Principal measurements

Schematic drawing

MPTK-I and MPTKR-I

Table of contents

Please click on the links below "table of contents" to get the information needed.

drawing, service instructions and more.

Here you will find technical documentation for Landia Chopperpump in the form of schematic

Dry installed ChopperpumpHP 400 US

landiainc.com

Elektric data 460V-60 Hz IE2

Elektric data 460V-60 Hz IE1

Elektric data

Page 2: Page 1/1 Dry installed Chopperpump

Scale: Sign.: Date:

Dwg.no.:

HL KSK 26-03-2001

37A0627MPTK-I / MPTKR-Iwith equipmentSchematic drawing

1 : 12

COPY

RIGH

T - Th

is dr

awing

is th

e pro

perty

of L

andia

and

cann

ot b

e sho

wn, c

opied

, give

n to

a thir

d pa

rty o

r use

d in

any o

ther w

ay w

ithou

t per

miss

ion fr

om La

ndia.

Connection from PN 6to ANSI-flange, outlet

Oil containerw/ bracket

Welding flange forsteel pipe - PN 6, outlet

Welding flange forsteel pipe, inlet

Connection toANSI-flange, inlet

Extended knife system

Knife system

Plastic container foroil collecting

Revision date: 06/22/2020

A

BC

D

F

E

Machine foot

Page 3: Page 1/1 Dry installed Chopperpump

CJ01A.C19

PRINCIPAL MEASUREMENTS & FIXING POINTS Page 1/5

Landia Inc. Issued on: 22. apr. 1999

Cary, NC 27513 Rev. date: 15. may 2009

Executed by: BN/ESK Accepted by: SL

Motor pump

Type MPTK-I 50 - 105

We reserve the right to make technical alterations.

Page 4: Page 1/1 Dry installed Chopperpump

CJ01A.C19

PRINCIPAL MEASUREMENTS & FIXING POINTS Page 2/5

Landia Inc. Issued on: 22. apr. 1999

Cary, NC 27513 Rev. date: 15. may 2009

Executed by: BN/ESK Accepted by: SL

Motor pump

Type MPTK-I 50 - 105 Medium pressure

Article no.

(460V)

Type

Power

[HP]

B

[mm]

D

[mm]

D1

[mm]

G

[mm]

H

[mm]

H1

[mm]

L1

[mm]

L3

[mm]

L4

[mm]

L5

[mm]

2524196 MPTK-I 50 0,9 170 Ø138 Ø10 M6 290 190 33 81 25 55

2524197 MPTK-I 50 1,2 170 Ø138 Ø10 M6 290 190 33 81 25 55

2524798 MPTK-I 65 1.8 178 Ø157 Ø10 M10 371 211 32,5 99,5 18,5 43

2524701 MPTK-I 65 2.4 178 Ø157 Ø10 M10 371 211 32,5 99,5 18,5 43

2524702 MPTK-I 65 3.6 192 Ø177 Ø12 M10 371 223 32,5 99,5 18,5 43

2524803 MPTK-I 80 4.9 188 Ø196 Ø12 M10 432 238 36,5 106 18 52,5

2524804 MPTK-I 80 6.5 224 Ø196 Ø12 M10 432 250 36,5 106 18 52,5

2524805 MPTK-I 80 9.0 256 Ø217 Ø12 M10 432 310 36,5 106 18 52,5

2524907 MPTK-I 105 12.2 256 Ø258 Ø12 M12 534 332 45 132 18 61

2524911 MPTK-I 105 17.9 296 Ø258 Ø15 M12 534 360 45 132 18 61

2524915 MPTK-I 105 24.5 296 Ø313 Ø15 M12 534 402 45 132 18 61

2524918 MPTK-I 105 30.2 328 Ø313 Ø15 M12 534 422 45 132 18 61

Article no.

(460V)

L6

[mm]

L7

[mm]

L8

[mm]

L9

[mm]

L10

[mm]

L11

[mm]

L12

[mm]

L13

[mm]

L14

[mm]

L15

[mm]

L16

[mm]

L17

[mm]

L18

[mm]

L19

[mm]

2514196 90 121 107,5 19 28 34 100 125 33 80 39 125 10 183,5

2514197 90 121 107,5 19 28 34 100 125 33 80 39 125 10 183,5

2524798 66 154,5 136 15,5 64 100 130 86 90 40 140 14 251

2524701 66 154,5 136 15,5 64 125 155 86 90 40 140 14 247

2524702 66 154,5 136 15,5 64 140 175 86 100 45 160 15 257

2524803 80 179,5 158,5 17,5 80 140 171 102 100 33 160 11 291

2524804 80 179,5 158,5 17,5 80 140 180 102 112 50 190 18 297

2524805 80 179,5 158,5 17,5 80 55 140 180 102 132 50 216 16 307

2524907 90 223 195 25 100 55 178 218 126 132 50 216 16 322

2524911 90 223 195 25 100 60 210 257 126 160 55 254 18 342

2524915 90 223 195 25 100 60 254 301 126 160 55 254 18 304

2524918 90 223 195 25 100 65 241 288 126 180 62 279 20 314

Page 5: Page 1/1 Dry installed Chopperpump

CJ01A.C19

PRINCIPAL MEASUREMENTS & FIXING POINTS Page 3/5

Landia Inc. Issued on: 22. apr. 1999

Cary, NC 27513 Rev. date: 15. may 2009

Executed by: BN/ESK Accepted by: SL

Motor pump

Type MPTK-I 50 / 65 / 80 High pressure

Article no.

(460V)

Type]

Power

[HP]

B

[mm]

D

[mm]

D1

[mm]

G

[mm]

H

[mm]

H1

[mm]

L1

[mm]

L3

[mm]

L4

[mm]

L5

[mm]

2522102 MPTK-I 50 3.6 178 Ø157 Ø10 M6 290 210 33 81 25 55

2522103 MPTK-I 50 4.9 192 Ø177 Ø12 M6 290 227 33 81 25 55

2522104 MPTK-I 50 6.5 224 Ø196 Ø12 M6 290 249 33 81 25 55

2522105 MPTK-I 50 9.0 192 Ø177 Ø12 M6 290 227 33 81 25 55

2522707 MPTK-I 65 12.2 256 Ø217 Ø12 M10 371 310 32,5 99,5 18,5 43

2522711 MPTK-I 65 17.9 296 Ø258 Ø15 M10 371 360 32,5 99,5 18,5 43

2522715 MPTK-I 65 24.5 296 Ø313 Ø15 M10 371 402 32,5 99,5 18,5 43

2522718 MPTK-I 65 30.2 296 Ø313 Ø15 M10 371 402 32,5 99,5 18,5 43

2522815 MPTK-I 80 24.5 296 Ø313 Ø15 M10 432 402 36,5 106 18 52,5

2522818 MPTK-I 80 30.2 296 Ø313 Ø15 M10 432 402 36,5 106 18 52,5

2522822 MPTK-I 80 35.4 328 Ø351 Ø15 M10 432 441 36,5 106 18 52,5

2522830 MPTK-I 80 48.9 372 Ø351 Ø19 M10 432 461 36,5 106 18 52,5

Article no.

(460V)

L6

[mm]

L7

[mm]

L8

[mm]

L9

[mm]

L10

[mm]

L11

[mm]

L12

[mm]

L13

[mm]

L14

[mm]

L15

[mm]

L16

[mm]

L17

[mm]

L18

[mm]

L19

[mm]

2522102 90 121 107.5 19 28 - 125 155 33 90 40 140 14 247

2522103 90 121 107.5 19 28 - 140 175 33 100 45 160 15 243

2522104 90 121 107.5 19 28 - 140 180 33 112 50 190 18 271

2522105 90 121 107.5 19 28 - 140 175 33 100 45 160 15 263

2522707 66 154,5 136 15,5 64 55 140 180 86 132 50 216 16 253

2522711 66 154,5 136 15,5 64 60 210 257 86 160 55 254 18 273

2522715 66 154,5 136 15,5 64 60 210 257 86 160 55 254 18 269

2522718 66 154,5 136 15,5 64 60 254 301 86 160 55 254 18 279

2522815 80 179,5 158,5 17,5 80 60 210 257 102 160 55 254 18 290

2522818 80 179,5 158,5 17,5 80 60 254 301 102 160 55 254 18 290

2522822 80 179,5 158,5 17,5 80 65 241 288 102 180 62 279 20 316

2522830 80 179,5 158,5 17,5 80 70 305 360 102 200 70 318 22 316

Page 6: Page 1/1 Dry installed Chopperpump

CJ01A.C19

PRINCIPAL MEASUREMENTS & FIXING POINTS Page 4/5

Landia Inc. Issued on: 22. apr. 1999

Cary, NC 27513 Rev. date: 15. may 2009

Executed by: BN/ESK Accepted by: SL

Motor pump

Type MPTK-I 150

Page 7: Page 1/1 Dry installed Chopperpump

CJ01A.C19

PRINCIPAL MEASUREMENTS & FIXING POINTS Page 5/5

Landia Inc. Issued on: 22. apr. 1999

Cary, NC 27513 Rev. date: 15. may 2009

Executed by: BN/ESK Accepted by: SL

Motor pump

Type MPTK-I 150

Medium pressure

Article no.

(460V)

Type

Power

[HP]

B

[mm]

D

[mm]

D1

[mm]

G

[mm]

H

[mm]

H1

[mm]

L1

[mm]

L2

[mm]

L3

[mm]

L4

[mm]

2524618 MPTK-I 150 30.2 328 Ø313 Ø15 M12 740 422 248 74 146 305

2524622 MPTK-I 150 35.4 328 Ø351 Ø15 M12 740 441 248 74 146 305

2524630 MPTK-I 150 48.9 372 Ø351 Ø15 M12 740 441 248 74 146 305

Article no.

(460V)

L5

[mm]

L6

[mm]

L7

[mm]

L8

[mm]

L9

[mm]

L10

[mm]

L11

[mm]

L12

[mm]

L13

[mm]

L15

[mm]

L16

[mm]

L17

[mm]

L18

[mm]

L19

[mm]

2524618 68 125 57 145 277 275 65 241 288 180 62 279 20 352

2524622 68 125 57 145 277 275 65 279 326 180 62 279 20 352

2524630 68 125 57 145 277 275 65 305 360 200 62 318 20 352

We reserve the right to make technical alterations.

Page 8: Page 1/1 Dry installed Chopperpump

CJ02A.C19

Principal measurements Page 1/4

Prepared by: GB/BNV Issued on: 14 October 1999 Approved by: SL Rev. date: 17 December 2019

W/knife system

W:

Machine foot

DIN 2631 PN 6 (MPTK 65-105)

DIN 2632 PN 10 (MPTK 150)

MPTK-I with support foot

Page 9: Page 1/1 Dry installed Chopperpump

CJ02A.C19

Principal measurements Page 2/4

Prepared by: GB/BNV Issued on: 14 October 1999 Approved by: SL Rev. date: 17 December 2019

W:

Machine foot

W/knife system

DIN 2631 PN 6 (MPTK 105)

DIN 2632 PN 10 (MPTK 150)

MPTK-I with support foot, increased height

Page 10: Page 1/1 Dry installed Chopperpump

CJ02A.C19

Principal measurements Page 3/4

Prepared by: GB/BNV Issued on: 14 October 1999 Approved by: SL Rev. date: 17 December 2019

MPTK-I with support foot Medium pressure

Article no. Power Dimensions Adjustable

(460V) [HP] A

[inch] B

[inch] C

[inch] D

[inch] E

[inch] F

[inch] G

[inch] H

[inch] I

[inch] J

[inch] J2

[inch] K

[inch] L

[inch] M

[mm] N

[mm] O

[mm] P

[mm] Q

[inch] R

[inch] S

[inch] T

[inch] U

[inch] V

[inch] W

[inch]

2524197 1.2 11.7 5.3 14.2 12.0 13.0 7.9 9.9 5.3 0.6 6.9 - 9.0 0.5 ø110 ø90 ø50 4xø10 10.7 11.5 6.3 9.9 1.7 1.4 1.0 - 1.6

2524798 1.8 17.9 9.8 17.9 14.8 16.6 12.2 12.6 6.9 0.6 10.7 - 15.4 0.6 ø160 ø130 ø67 4xø14 16.7 14.6 8.1 15.6 1.8 1.5 1.2 - 3.0

2524701 2.4 17.9 9.8 18.9 15.8 16.6 12.2 12.6 6.9 0.6 10.7 - 15.4 0.6 ø160 ø130 ø67 4xø14 16.7 14.6 8.1 15.6 1.8 1.5 1.2 - 3.0

2524702 3.6 17.9 9.8 19.3 16.1 16.6 12.2 12.6 6.9 0.7 10.7 - 15.4 0.6 ø160 ø130 ø67 4xø14 16.7 14.6 8.1 15.6 1.8 1.5 1.2 - 3.0

2524803 4.9 20.6 11.0 22.4 18.7 19.3 13.4 14.7 8.1 0.8 11.8 - 18.1 0.6 ø190 ø150 ø80 4xø18 19.1 17.0 9.5 17.5 2.2 1.9 1.2 - 3.0

2524804 6.5 20.6 11.0 23.8 20.1 19.3 13.4 14.7 8.1 0.8 11.8 - 18.1 0.6 ø190 ø150 ø80 4xø18 19.1 17.0 9.5 17.5 2.2 1.9 1.2 - 3.0

2524805 9.0 20.6 11.0 25.0 21.3 19.3 13.4 14.7 8.1 1.4 11.8 - 18.1 0.6 ø190 ø150 ø80 4xø18 19.1 17.0 9.5 17.5 2.2 1.9 1.2 - 3.0

2524907 12.2 25.2 13.4 26.4 22.2 21.5 15.4 18.1 9.8 1.4 13.8 - 20.3 0.6 ø210 ø170 ø105 4xø18 23.2 21.0 11.8 21.5 2.8 2.3 1.4 - 3.4

2524911 17.9 25.2 13.4 28.4 24.2 21.5 13.4 18.1 9.8 1.4 13.8 - 20.3 0.6 ø210 ø170 ø105 4xø18 23.2 21.0 11.8 21.5 2.8 2.3 1.4 - 3.4

2524915 24.5 25.2 13.4 28.7 24.6 21.5 15.4 18.1 9.8 1.4 13.8 - 20.3 0.6 ø210 ø170 ø105 4xø18 23.2 21.0 11.8 21.5 2.8 2.3 1.4 - 3.4

2524918 30.2 25.2 13.4 28.7 24.6 21.5 15.4 18.1 9.8 1.4 13.8 - 20.3 0.6 ø210 ø170 ø105 4xø18 23.2 21.0 11.8 21.5 2.8 2.3 1.4 - 3.4

2524622 35.4 32.5 15.0 34.4 28.6 23.7 17.8 22.9 12.6 1.4 15.0 7.9 22.1 0.6 ø285 ø240 ø150 8xø22 27.6 29.2 17.5 25.3 2.9 3.0 1.4 - 3.4

2524630 48.9 32.5 15.0 34.4 28.6 24.8 17.8 22.9 12.6 1.4 15.0 7.9 22.8 0.6 ø285 ø240 ø150 8xø22 27.6 29.2 17.5 25.3 2.9 3.0 1.4 - 3.4

MPTK-I with support foot, increased height Medium pressure

Article no. Power Dimensions Adjustable

(460V) [HP] A1

[inch] B1

[inch] C

[inch] D

[inch] E1

[inch] F2

[inch] G

[inch] H

[inch] I

[inch] J

[inch] J3

[inch] K1

[inch] L

[inch] M

[mm] N

[mm] O

[mm] P

[mm] Q1

[inch] R

[inch] S

[inch] T1

[inch] U

[inch] V

[inch] W

[inch]

2524907 12.2 36.7 24.9 26.4 22.2 19.1 17.5 18.1 9.8 1.4 - 15.4 16.7 0.6 ø210 ø170 ø105 4xø18 34.7 21.0 11.8 33.0 2.8 2.3 1.4 - 3.4

2524911 17.9 37.8 26.0 28.4 24.2 21.2 19.9 18.1 9.8 1.4 - 16.9 18.7 0.6 ø210 ø170 ø105 4xø18 35.8 21.0 11.8 34.1 2.8 2.3 1.4 - 3.4

2524915 24.5 37.8 26.0 28.7 24.6 21.2 19.9 18.1 9.8 1.4 - 16.9 18.7 0.6 ø210 ø170 ø105 4xø18 35.8 21.0 11.8 34.1 2.8 2.3 1.4 - 3.4

2524918 30.2 38.6 26.8 28.7 24.6 22.2 20.3 18.1 9.8 1.4 - 18.1 19.9 0.6 ø210 ø170 ø105 4xø18 36.6 21.0 11.8 34.8 2.8 2.3 1.4 - 3.4

2524622 35.4 44.2 26.8 34.4 28.6 22.2 20.3 22.9 12.6 1.4 - 18.1 19.9 0.6 ø285 ø240 ø150 8xø22 39.4 29.2 17.5 37.0 2.9 3.0 1.4 - 3.4

2524630 48.9 45.0 27.6 34.4 28.6 23.8 20.3 22.9 12.6 1.4 - 18.1 21.3 0.6 ø285 ø240 ø150 8xø22 40.2 29.2 17.5 37.8 2.9 3.0 1.4 - 3.4

Page 11: Page 1/1 Dry installed Chopperpump

CJ02A.C19

Principal measurements Page 4/4

Prepared by: GB/BNV Issued on: 14 October 1999 Approved by: SL Rev. date: 17 December 2019

MPTK-I with support foot High pressure

Article no. Power Dimensions Adjustable

(460V) [HP] A

[inch] B

[inch] C

[inch] D

[inch] E

[inch] F

[inch] G

[inch] H

[inch] I

[inch] J

[inch] J2

[inch] K

[inch] L

[inch] M

[mm] N

[mm] O

[mm] P

[mm] Q

[inch] R

[inch] S

[inch] T

[inch] U

[inch] V

[inch] W

[inch]

2522102 3.6 16.2 9.9 17.8 15.6 16.6 12.2 9.9 5.3 0.6 10.7 - 15.4 0.6 Ø110 Ø90 Ø50 4xø10 15.2 11.5 6.3 14.4 1.7 1.4 1.2 - 3.0

2522103 4.9 16.2 9.9 18.4 16.2 16.6 12.2 9.9 5.3 0.7 10.7 - 15.4 0.6 Ø110 Ø90 Ø50 4xø10 15.2 11.5 6.3 14.4 1.7 1.4 1.2 - 3.0

2522104 6.5 17.4 11.0 20.1 18.0 19.3 13.4 9.9 5.3 0.8 11.8 - 18.1 0.6 Ø110 Ø90 Ø50 4xø10 16.4 11.5 6.3 15.6 1.7 1.4 1.2 - 3.0

2522105 9.0 16.2 11.0 21.5 19.3 16.6 12.2 9.9 5.3 0.7 10.7 - 15.4 0.6 Ø110 Ø90 Ø50 4xø10 15.2 11.5 6.3 14.4 1.7 1.4 1.2 - 3.0

2522707 12.2 19.2 11.0 23.9 20.7 19.3 13.4 12.6 6.9 1.4 11.8 - 18.1 0.6 Ø160 Ø130 Ø67 4xø14 18.0 14.6 8.1 16.8 1.8 1.5 1.2 - 3.0

2522711 17.9 21.5 13.4 25.7 22.5 21.5 15.4 12.6 6.9 1.4 13.8 - 20.3 0.6 Ø160 Ø130 Ø67 4xø14 20.3 14.6 8.1 19.2 1.8 1.5 1.4 - 3.4

2522715 24.5 21.5 13.4 25.9 22.7 21.5 15.4 12.6 6.9 1.4 13.8 - 20.3 0.6 Ø160 Ø130 Ø67 4xø14 20.3 14.6 8.1 19.2 1.8 1.5 1.4 - 3.4

2522718 30.2 21.5 13.4 27.4 24.3 21.5 15.4 12.6 6.9 1.4 13.8 - 20.3 0.6 Ø160 Ø130 Ø67 4xø14 20.3 14.6 8.1 19.2 1.8 1.5 1.4- 3.4

2522815 24.5 24.5 15.0 26.8 23.1 23.6 17.7 14.6 8.1 1.4 15.0 - 21.7 0.6 Ø190 Ø150 Ø80 4xø18 21.5 17.0 9.5 19.9 2.2 2.0 1.4- 3.4

2522818 30.2 24.5 15.0 28.3 24.6 23.6 17.7 14.6 8.1 1.4 15.0 - 21.7 0.6 Ø190 Ø150 Ø80 4xø18 21.5 17.0 9.5 19.9 2.2 2.0 1.4- 3.4

2522822 35.4 24.5 15.0 29.9 26.1 23.6 17.7 14.6 8.1 1.4 15.0 7.9 22.0 0.6 Ø190 Ø150 Ø80 4xø18 23.0 17.0 9.5 21.5 2.2 2.0 1.4- 3.4

2522830 48.9 24.5 15.0 31.7 28.0 24.8 17.7 14.6 8.1 1.4 15.0 7.9 22.8 0.6 Ø190 Ø150 Ø80 4xø18 23.0 17.0 9.5 21.5 2.2 2.0 1.4- 3.4

MPTK-I with support foot, increased height Medium pressure

Article no. Power Dimensions Adjustable

(460V) [HP] A1

[inch] B1

[inch] C

[inch] D

[inch] E1

[inch] F2

[inch] G

[inch] H

[inch] I

[inch] J

[inch] J3

[inch] K1

[inch] L

[inch] M

[mm] N

[mm] O

[mm] P

[mm] Q1

[inch] R

[inch] S

[inch] T1

[inch] U

[inch] V

[inch] W

[inch]

2522815 24.5 35.5 26.0 26.8 23.1 21.2 19.9 14.6 8.1 1.4 - 16.9 18.7 0.6 Ø190 Ø150 Ø80 4xø18 32.5 17.0 9.5 30.9 2.2 2.0 1.4- 3.4

2522818 30.2 35.5 26.0 28.3 24.6 21.2 19.9 14.6 8.1 1.4 - 16.9 18.7 0.6 Ø190 Ø150 Ø80 4xø18 32.5 17.0 9.5 30.9 2.2 2.0 1.4- 3.4

2522822 35.4 36.3 26.8 29.9 26.1 22.2 20.3 14.6 8.1 1.4 - 18.1 19.9 0.6 Ø190 Ø150 Ø80 4xø18 34.8 17.0 9.5 33.3 2.2 2.0 1.4- 3.4

2522830 48.9 37.1 27.6 31.7 28.0 23.8 20.3 14.6 8.1 1.4 - 18.1 21.3 0.6 Ø190 Ø150 Ø80 4xø18 39.6 17.0 9.5 34.1 2.2 2.0 1.4- 3.4

We reserve the right to make technical alterations

Page 12: Page 1/1 Dry installed Chopperpump

Data Sheet CJ00A.C13

landiainc.com

Prepared by: BNV/GB Approved by: KSK/TM

Issued on: 1 June 2018

Rev. date: 1. March 2021

Page - 1 -/9

MPTK-I

The MPTK-I pump is a highly efficient chopper pump designed for

pumping heavily contaminated liquids as well as liquids with a

high dry matter content, e.g. dewatered sludge.

All MPTK-I pumps are equipped with a knife system at the inlet

to the pump, which ensures problem-free operations under

conditions where many other pumps have problems with

clogging

APPLICATION EXAMPLES

Sewage treatment plants

Pumping stations

Biogas plants

Food industry

Pumping abrasive liquids or liquids with high viscosity

PUMP RPM

1,800 rpm

3,600 rpm

MATERIAL OF CONSTRUCTION

Motor housing and oil chamber Cast iron AISI A48-40B

Pump housing Cast iron AISI A48-40B

Pump impeller

Cast iron AISI A48-40B

Cast iron AISI 100-70-03 (optional)

Cast iron CF-8M (optional)

Pump shaft AISI 4340

Bolts Steel AISI 316

Sealing system Mechanical shaft seals: silicon carbide/silicon carbide

Knife system Hardened steel A 570 GR 36 (*)

Acid-proof steel AISI 316 (optional)

Extended knife system Hardened steel A 570 GR 36 (optional)

Acid-proof steel AISI 316 (optional)

Oil type 15W-40

Vario HDX (with moisture detection)

(*) On the MPTK-I, the knife system is optional. The MPTK-I Ex includes the knife system

Page 13: Page 1/1 Dry installed Chopperpump

Data Sheet CJ00A.C13

landiainc.com

Prepared by: BNV/GB Approved by: KSK/TM

Issued on: 1 June 2018

Rev. date: 1. March 2021

SERVICE AND MAINTENANCE

Page 2/9

Recommended service interval/oil change Maximum 2,000 operating hours/minimum once a year

Motor Lifetime lubricated bearings

Oil chamber Periodic oil change

SURFACE TREATMENT

Machinery enamel: RAL 9005 (Jet Black) Jet Black

2-component coating: RAL 7005 (Mouse Grey) (optional) Mouse Grey

MONITORING FUNCTIONS

Thermistor 284 °F

Moisture detection system (optional)

Page 14: Page 1/1 Dry installed Chopperpump

Data Sheet CJ00A.C13

landiainc.com

Prepared by: BNV/GB Approved by: KSK/TM

Issued on: 1 June 2018

Rev. date: 1. March 2021

DESIGN

Page 3/9

The open pump impeller design means that the chopper pump can pump liquids with a high viscosity. For

liquids containing abrasive particles, such as sand, Landia has developed special materials so that the pump’s

life span is extended significantly in comparison to a standard pump.

A large part of the MPTK-I programme can be supplied in acid-proof steel for aggressive liquids with a high or

low pH.

MPTK-I pumps can be equipped with a knife system at the inlet to the pump, which ensures problem-free

operation under conditions where many other pumps have problems with clogging.

Oil chamber

Pump housing

Mechanical shaft seal

Page 15: Page 1/1 Dry installed Chopperpump

Data Sheet CJ00A.C13

landiainc.com

Prepared by: BNV/GB Approved by: KSK/TM

Issued on: 1 June 2018

Rev. date: 1. March 2021

ELECTRICAL DATA

Page 4/9

Motor type 3-phase AC motor

Nominal voltage 460 V

Minimum voltage allowed 415 V

Nominal frequency 60 Hz

Suitable for VFD-operation Yes

Cage class IP 55

Insulation class F

Mo

de

l

It

em

nu

mb

er

N

om

ina

l p

ow

er

M

oto

r

Fu

ll l

oa

d c

urr

en

t

(46

0 V

)

C

on

ne

ctio

n

me

tho

d

Sta

rt c

urr

en

t

(DO

L)

cos

ph

i

Eff

icie

ncy

(10

0%

)

[HP] [rpm] [A] [V] Y/∆ [A] [%]

MPTK-I 50 0.9 HP-1800 rpm 2524196 0.9 1710 1.8 460 Y 8 0.66 71.0

MPTK-I 50 1.2 HP-1800 rpm 2524197 1.2 1710 2.3 460 Y 11 0.68 74.0

MPTK-I 65 1.8 HP-1800 rpm 2524798 1.8 1720 2.8 460 Y 15 0.77 77.0

MPTK-I 65 2.4 HP-1800 rpm 2524701 2.4 1710 3.7 460 Y 21 0.77 80.0

MPTK-I 65 3.6 HP-1800 rpm 2524702 3.6 1720 5.3 460 Y 34 0.75 81.0

MPTK-I 80 4.9 HP-1800 rpm 2524803 4.9 1730 7.0 460 Δ 48 0.77 84.0

MPTK-I 80 6.5 HP-1800 rpm 2524804 6.5 1735 9.0 460 Δ 66 0.78 85.0

MPTK-I 80 9.0 HP-1800 rpm 2524805 9.0 1745 11.0 460 Δ 72 0.88 86.0

MPTK-I 105 12.2 HP-1800 rpm 2524907 12.2 1750 15.5 460 Δ 93 0.84 87.0

MPTK-I 105 17.9 HP-1800 rpm 2524911 17.9 1755 22.0 460 Δ 152 0.84 88.4

MPTK-I 105 24.5 HP-1800 rpm 2524915 24.5 1765 29.5 460 Δ 224 0.86 89.4

MPTK-I 105 30.2 HP-1800 rpm 2524918 30.2 1760 36.0 460 Δ 241 0.85 90.0

MPTK-I 150 30.2 HP-1800 rpm 2524618 30.2 1760 36.0 460 Δ 241 0.85 90.0

MPTK-I 150 35.4 HP-1800 rpm 2524622 35.4 1765 43.5 460 Δ 283 0.83 90.5

MPTK-I 150 48.9 HP-1800 rpm 2524630 48.9 1765 59.0 460 Δ 413 0.84 91.5

Page 16: Page 1/1 Dry installed Chopperpump

Data Sheet CJ00A.C13

landiainc.com

Prepared by: BNV/GB Approved by: KSK/TM

Issued on: 1 June 2018

Rev. date: 1. March 2021

ELECTRICAL DATA

Page 5/9

Motor type 3-phase AC motor

Nominal voltage 460 V

Minimum voltage allowed 415 V

Nominal frequency 60 Hz

Suitable for VFD-operation Yes

Cage class IP 55

Insulation class F

Mo

de

l

It

em

nu

mb

er

N

om

ina

l p

ow

er

M

oto

r

Fu

ll l

oa

d c

urr

en

t

(46

0 V

)

C

on

ne

ctio

n

me

tho

d

Sta

rt c

urr

en

t

(DO

L)

cos

ph

i

Eff

icie

ncy

(10

0%

)

[HP] [rpm] [A] [V] Y/∆ [A] [%]

MPTK-I 50 3.6 HP-3600 rpm 2522102 3.6 3460 4.9 460 Y 37 0.85 83.0

MPTK-I 50 4.9 HP-3600 rpm 2522103 4.9 3470 6.5 460 Δ 40 0.83 85.5

MPTK-I 50 6.5 HP-3600 rpm 2522104 6.5 3500 8.9 460 Δ 68 0.80 87.0

MPTK-I 50 9.0 HP-3600 rpm 2522105 9.0 3430 11.5 460 Δ 63 0.85 85.7

MPTK-I 65 12.2 HP-3600 rpm 2522707 12.2 3480 15.0 460 Δ 99 0.86 87.0

MPTK-I 65 17.9 HP-3600 rpm 2522711 17.9 3480 20.5 460 Δ 144 0.90 88.0

MPTK-I 65 24.5 HP-3600 rpm 2522715 24.5 3530 28.0 460 Δ 199 0.90 89.6

MPTK-I 65 30.2 HP-3600 rpm 2522718 30.2 3520 33.0 460 Δ 238 0.92 90.5

MPTK-I 80 24.5 HP-3600 rpm 2522815 24.5 3530 28.0 460 Δ 199 0.90 89.6

MPTK-I 80 30.2 HP-3600 rpm 2522818 30.2 3520 33.0 460 Δ 238 0.92 90.5

MPTK-I 80 35.4 HP-3600 rpm 2522822 35.4 3535 38.5 460 Δ 270 0.92 92.0

MPTK-I 80 48.9 HP-3600 rpm 2522830 48.9 3550 53.0 460 Δ 392 0.92 93.0

Page 17: Page 1/1 Dry installed Chopperpump

Data Sheet CJ00A.C13

landiainc.com

Prepared by: BNV/GB Approved by: KSK/TM

Issued on: 1 June 2018

Rev. date: 1. March 2021

OVERALL DIMENSIONS

Page 6/9

Model Item

number

A

[inch]

B

[inch]

C

[inch]

D

[inch]

G

[inch]

H

[inch]

Weight [lb]

MPTK-I 50 0.9 HP-1800 rpm 2524196 11.7 5.3 14.2 12.0 9.9 5.3 55

MPTK-I 50 1.2 HP-1800 rpm 2524197 11.7 5.3 14.2 12.0 9.9 5.3 55

MPTK-I 65 1.8 HP-1800 rpm 2524798 17.9 9.8 17.9 14.8 12.6 6.9 99

MPTK-I 65 2.4 HP-1800 rpm 2524701 17.9 9.8 18.9 15.8 12.6 6.9 110

MPTK-I 65 3.6 HP-1800 rpm 2524702 17.9 9.8 19.3 16.1 12.6 6.9 121

MPTK-I 80 4.9 HP-1800 rpm 2524803 20.6 11.0 22.4 18.7 14.7 8.1 176

MPTK-I 80 6.5 HP-1800 rpm 2524804 20.6 11.0 23.8 20.1 14.7 8.1 187

MPTK-I 80 9.0 HP-1800 rpm 2524805 20.6 11.0 25.0 21.3 14.7 8.1 220

MPTK-I 105 12.2 HP-1800 rpm 2524907 25.2 13.4 26.4 22.2 18.1 9.8 309

MPTK-I 105 17.9 HP-1800 rpm 2524911 25.2 13.4 28.4 24.2 18.1 9.8 353

MPTK-I 105 24.5 HP-1800 rpm 2524915 25.2 13.4 28.7 24.6 18.1 9.8 441

MPTK-I 105 30.2 HP-1800 rpm 2524918 25.2 13.4 28.7 24.6 18.1 9.8 463

MPTK-I 150 30.2 HP-1800 rpm 2524618 32.5 15.0 30.6 28.6 22.9 12.6 595

MPTK-I 150 35.4 HP-1800 rpm 2524622 32.5 15.0 34.4 28.6 22.9 12.6 728

MPTK-I 150 48.9 HP-1800 rpm 2524630 32.5 15.0 34.4 28.6 22.9 12.6 794

Page 18: Page 1/1 Dry installed Chopperpump

Data Sheet CJ00A.C13

landiainc.com

Prepared by: BNV/GB Approved by: KSK/TM

Issued on: 1 June 2018

Rev. date: 1. March 2021

Page 7/90

OVERALL DIMENSIONS

Model

Item number

A

[inch]

B

[inch]

C

[inch]

D

[inch]

G

[inch]

H

[inch]

Weight

[lb]

MPTK-I 50 3.6 HP-3600 rpm 2522102 16.2 9.9 17.8 15.6 9.9 5.3 79

MPTK-I 50 4.9 HP-3600 rpm 2522103 16.2 9.9 18.4 16.2 9.9 5.3 90

MPTK-I 50 6.5 HP-3600 rpm 2522104 17.4 11.0 20.1 18.0 9.9 5.3 117

MPTK-I 50 9.0 HP-3600 rpm 2522105 16.2 11.0 21.5 19.3 9.9 5.3 134

MPTK-I 65 12.2 HP-3600 rpm 2522707 19.2 11.0 23.9 20.7 12.6 6.9 176

MPTK-I 65 17.9 HP-3600 rpm 2522711 21.5 13.4 25.7 22.5 12.6 6.9 231

MPTK-I 65 24.5 HP-3600 rpm 2522715 21.5 13.4 25.9 22.7 12.6 6.9 309

MPTK-I 65 30.2 HP-3600 rpm 2522718 21.5 13.4 27.4 24.3 12.6 6.9 342

MPTK-I 80 24.5 HP-3600 rpm 2522815 24.5 15.0 26.8 23.1 14.6 8.1 414

MPTK-I 80 30.2 HP-3600 rpm 2522818 24.5 15.0 28.3 24.6 14.6 8.1 452

MPTK-I 80 35.4 HP-3600 rpm 2522822 24.5 15.0 29.9 26.1 14.6 8.1 569

MPTK-I 80 48.9 HP-3600 rpm 2522830 24.5 15.0 31.7 28.0 14.6 8.1 672

Page 19: Page 1/1 Dry installed Chopperpump

Data Sheet CJ00A.C13

landiainc.com

Prepared by: BNV/GB Approved by: KSK/TM

Issued on: 1 June 2018

Rev. date: 1. March 2021

Page 8/9

OVERALL DIMENSIONS ST. STEEL CONNECTION TO ANSI FLANGE FOR MPTK-I/MPTKR-I

Pump

series

Loose

flange

ANSI

150 LB

Dimensions [inches]

A

B

C

ø

D

ø

E

ø

F

ø

G

ø

H I J

No. of

bolts

Diam.

of

bolts

65 5” 0.5 8.86 5.5 5.3 7.4 8.5 10 8 3/4 1.53 7.33

65 6” 0.6 8.86 6.6 6.4 8.3 9.5 11 8 3/4 1.53 7.33

65 8” 0.6 8.86 8.6 8.4 10.6 11.75 13.5 8 3/4 1.53 7.33

80 4” 0.5 8.86 4.5 4.3 6.2 7.5 9 8 5/8 1.89 6.97

80 5” 0.5 8.86 5.5 5.3 7.4 8.5 10 8 3/4 1.89 6.97

80 6” 0.6 8.86 6.6 6.4 8.3 9.5 11 8 3/4 1.89 6.97

80 8” 0.6 8.86 8.6 8.4 10.6 11.75 13.5 8 3/4 1.89 6.97

80 10” 0.6 8.86 10.2 9.8 12.2 14.25 16 12 7/8 1.89 6.97

105 6” 0.6 8.86 6.6 6.4 8.3 9.5 11 8 3/4 2.32 6.54

105 8” 0.6 8.86 8.6 8.4 10.6 11.75 13.5 8 3/4 2.32 6.54

105 10” 0.6 8.86 10.2 9.8 12.2 14.25 16 12 7/8 2.32 6.54

150 8” 0.6 8.86 8.6 8.6 10.6 11.75 13.5 8 7/8 2.99 5.87

150 10” 0.6 8.86 10.1 9.8 12.6 14.25 16 12 7/8 2.99 5.87

150 12” .06 8.86 12.6 12.6 14.6 17 19 12 7/8 2.99 5.87

Page 20: Page 1/1 Dry installed Chopperpump

Data Sheet CJ00A.C13

landiainc.com

Prepared by: BNV/GB Approved by: KSK/TM

Issued on: 1 June 2018

Rev. date: 1. March 2021

Page 9/9

OVERALL DIMENSIONS St. steel CONNECTION TO ANSI FLANGE FOR MPTK-I/MPTKR-I

Pump

series

Coupling

foot

ANSI

150 LB

Dimensions [inches]

A

B

C

ø

D

ø

E

ø

F

ø

G

ø

H

No.

Of

bolts

Diam.

of

bolts

65 3” 0.5 5.9 3 2.8 4.8 6 7.5 4 5/8

65 4” 0.5 5.9 4.5 4.3 6.2 7.5 9 8 5/8

80 65/80 3” 0.5 5.9 3 2.8 4.8 6 7.5 4 5/8

80 65/80 4” 0.5 5.9 4.5 4.3 6.2 7.5 9 8 5/8

80 65/80 5” 0.5 5.9 5.5 5.3 7.4 8.5 10 8 3/4

80 65/80 6” 0.5 5.9 6.6 6.4 8.3 9.5 11 8 3/4

105 105 4” 0.5 5.9 4.5 4.3 6.2 7.5 9 8 5/8

105 105 5” 0.5 5.9 5.5 5.3 7.4 8.5 10 8 3/4

105 105 6” 0.5 5.9 6.6 6.4 8.3 9.5 11 8 3/4

We reserve the right to make technical alterations.

Page 21: Page 1/1 Dry installed Chopperpump

landiainc.com

Prepared by: BNV/GB Approved by: KSK/TM

Issued on: 1 June 2018 Rev. date: 21. March 2021

Data Sheet CJ00B.C13

Page 1 of 8

MPTKR-I

The MPTKR-I pump is a highly efficient chopper pump

made entirely of acid-proof steel. It is ideal for aggressive

liquids with a low or high PH value, as well as liquids with a

high dry matter content.

All MPTKR-I pumps can be equipped with a knife system

at the inlet to the pump, which can ensureproblem-free

operations under conditions where many other pumps

have problems with clogging.

APPLICATION EXAMPLES

Chemical industry

Paper industry

Food industry

Biogas plants

Pumping abrasive or aggressive l

PUMP RPM

1,800 rpm

3,600 rpm

MATERIAL OF CONSTRUCTION

Motor housing and oil chamber Cast iron AISI A48-40B

Pump housing Cast iron CF-8M

Pump impeller Cast iron CF-8M

Pump shaft AISI 316

Bolts Steel AISI 316

Sealing system Mechanical shaft seals: silicon carbide/silicon carbide

Knife system Steel AISI 316 (*)

Extended knife system Steel AISI 316 (optional)

Oil type 15W-40

Vario HDX (with moisture detection)

(*) On the MPTKR-I, the knife system is optional. The MPTKR-I Ex includes the knife system.

Page 22: Page 1/1 Dry installed Chopperpump

landiainc.com

Prepared by: BNV/GB Approved by: KSK/TM

Issued on: 1 June 2018 Rev. date: 21. March 2021

Data Sheet CJ00B.C13

Page 2 of 8

SERVICE AND MAINTENANCE

Recommended service interval/oil change Maximum 2,000 operating hours/minimum once a year

Motor Lifetime lubricated bearings

Oil chamber Periodic oil change

SURFACE TREATMENT

Machinery enamel: RAL 9005 (Jet Black) Jet Black

2-component coating: RAL 7005 (Mouse Grey) (optional) Mouse Grey

MONITORING FUNCTIONS

Thermistor 284 °F

Moisture detection system (optional)

Page 23: Page 1/1 Dry installed Chopperpump

landiainc.com

Prepared by: BNV/GB Approved by: KSK/TM

Issued on: 1 June 2018 Rev. date: 21. March 2021

Data Sheet CJ00B.C13

Page 3 of 8

DESIGN

The open pump impeller design means that the chopper pump can pump liquids with a high viscosity. For

liquids containing abrasive particles, such as sand, Landia has developed special materials so that the pump’s

life span is extended significantly in comparison to a standard pump.

A large part of the MPTKR-I programme can be supplied in acid-proof steel for aggressive liquids with a high

or low pH.

The chopper pumps can be equipped with a knife system at the inlet to the pump, which ensure problem-

free operations under conditions where many other pumps have problems with clogging.

Pump housing

Mechanical shaft seal

Oil chamber

Page 24: Page 1/1 Dry installed Chopperpump

landiainc.com

Prepared by: BNV/GB Approved by: KSK/TM

Issued on: 1 June 2018 Rev. date: 21. March 2021

Data Sheet CJ00B.C13

Page 4 of 8

ELECTRICAL DATA

Motor type 3-phase AC motor

Nominal voltage 460 V

Minimum voltage allowed 415 V

Nominal frequency 60 Hz

Suitable for VFD-operation Yes

Cage class IP 55

Insulation class F

Mo

de

l

It

em

nu

mb

er

N

om

ina

l p

ow

er

M

oto

r

Fu

ll l

oa

d c

urr

en

t

(46

0 V

)

C

on

ne

ctio

n

me

tho

d

Sta

rt c

urr

en

t

(DO

L)

cos

ph

i

Eff

icie

ncy

(10

0%

)

[HP] [rpm] [A] [V] Y/∆ [A] [%]

MPTKR-I 65 1.8 HP-1800 rpm 2524298 1.8 1720 2.8 460 Y 15 0.77 77.0

MPTKR-I 65 2.4 HP-1800 rpm 2524201 2.4 1710 3.7 460 Y 21 0.77 80.0

MPTKR-I 65 3.6 HP-1800 rpm 2524202 3.6 1720 5.3 460 Y 34 0.75 81.0

MPTKR-I 80 4.9 HP-1800 rpm 2524203 4.9 1730 7.0 460 Δ 48 0.77 84.0

MPTKR-I 80 6.5 HP-1800 rpm 2524204 6.5 1735 9.0 460 Δ 66 0.78 85.0

MPTKR-I 80 9.0 HP-1800 rpm 2524205 9.0 1745 11.0 460 Δ 72 0.88 86.0

MPTKR-I 105 12.2 HP-1800 rpm 2524207 12.2 1750 15.5 460 Δ 93 0.84 87.0

MPTKR-I 105 17.9 HP-1800 rpm 2524211 17.9 1755 22.0 460 Δ 152 0.84 88.4

MPTKR-I 105 24.5 HP-1800 rpm 2524215 24.5 1765 29.5 460 Δ 224 0.86 89.4

MPTKR-I 105 30.2 HP-1800 rpm 2524218 30.2 1760 36.0 460 Δ 241 0.85 90.0

MPTKR-I 105 35.4 HP-1800 rpm 2524222 35.4 1765 43.5 460 Δ 283 0.83 90.5

MPTKR-I 105 48.9 HP-1800 rpm 2524230 48.9 1765 59.0 460 Δ 413 0.84 91.5

Page 25: Page 1/1 Dry installed Chopperpump

landiainc.com

Prepared by: BNV/GB Approved by: KSK/TM

Issued on: 1 June 2018 Rev. date: 21. March 2021

Data Sheet CJ00B.C13

Page 5 of 8

ELECTRICAL DATA

Motor type 3-phase AC motor

Nominal voltage 460 V

Minimum voltage allowed 415 V

Nominal frequency 60 Hz

Suitable for VFD-operation Yes

Cage class IP 55

Insulation class F

Mo

de

l

It

em

nu

mb

er

N

om

ina

l p

ow

er

M

oto

r

Fu

ll l

oa

d c

urr

en

t

(46

0 V

)

C

on

ne

ctio

n

me

tho

d

Sta

rt c

urr

en

t

(DO

L)

cos

ph

i

Eff

icie

ncy

(10

0%

)

[HP] [rpm] [A] [V] Y/∆ [A] [%]

MPTKR-I 65 12.2 HP-3600 rpm 2522207 12.2 3480 15.0 460 Δ 99 0.86 87.0

MPTKR-I 65 17.9 HP-3600 rpm 2522211 17.9 3480 20.5 460 Δ 144 0.90 88.0

MPTKR-I 65 24.5 HP-3600 rpm 2522212 24.5 3530 28.0 460 Δ 199 0.90 89.6

MPTKR-I 65 30.2 HP-3600 rpm 2522213 30.2 3520 33.0 460 Δ 238 0.92 90.5

MPTKR-I 80 24.5 HP-3600 rpm 2522215 24.5 3530 28.0 460 Δ 199 0.90 89.6

MPTKR-I 80 30.2 HP-3600 rpm 2522218 30.2 3520 33.0 460 Δ 238 0.92 90.5

MPTKR-I 80 35.4 HP-3600 rpm 2522222 35.4 3535 38.5 460 Δ 270 0.92 92.0

MPTKR-I 80 48.9 HP-3600 rpm 2522230 48.9 3550 53.0 460 Δ 392 0.92 93.0

Page 26: Page 1/1 Dry installed Chopperpump

landiainc.com

Prepared by: BNV/GB Approved by: KSK/TM

Issued on: 1 June 2018 Rev. date: 21. March 2021

Data Sheet CJ00B.C13

Page 6 of 8

OVERALL DIMENSIONS

Model Item

number

A

[inch]

B

[inch]

C

[inch]

D

[inch]

G

[inch]

H

[inch]

Weight

[lb]

MPTKR-I 65 1.8 HP-1800 rpm 2524298 17.9 9.8 17.9 14.8 12.6 6.9 99

MPTKR-I 65 2.4 HP-1800 rpm 2524201 17.9 9.8 18.9 15.8 12.6 6.9 110

MPTKR-I 65 3.6 HP-1800 rpm 2524202 17.9 9.8 19.3 16.1 12.6 6.9 121

MPTKR-I 80 4.9 HP-1800 rpm 2524203 20.6 11.0 22.4 18.7 14.7 8.1 176

MPTKR-I 80 6.5 HP-1800 rpm 2524204 20.6 11.0 23.8 20.1 14.7 8.1 187

MPTKR-I 80 9.0 HP-1800 rpm 2524205 20.6 11.0 25.0 21.3 14.7 8.1 220

MPTKR-I 105 12.2 HP-1800 rpm 2524207 25.2 13.4 26.4 22.2 18.1 9.8 348

MPTKR-I 105 17.9 HP-1800 rpm 2524211 25.2 13.4 28.4 24.2 18.1 9.8 392

MPTKR-I 105 24.5 HP-1800 rpm 2524215 25.2 13.4 28.7 24.6 18.1 9.8 474

MPTKR-I 105 30.2 HP-1800 rpm 2524218 25.2 13.4 28.7 24.6 18.1 9.8 503

MPTKR-I 105 35.4 HP-1800 rpm 2524222 25.2 13.4 31.3 27.2 18.1 9.8 683

MPTKR-I 105 48.9 HP-1800 rpm 2524230 25.2 13.4 31.3 27.2 18.1 9.8 794

Page 27: Page 1/1 Dry installed Chopperpump

landiainc.com

Prepared by: BNV/GB Approved by: KSK/TM

Issued on: 1 June 2018 Rev. date: 21. March 2021

Data Sheet CJ00B.C13

Page 7 of 8

OVERALL DIMENSIONS ST. STEEL CONNECTION TO ANSI FLANGE FOR MPTK-I/MPTKR-I

P

Pump

series

Loose

flange

ANSI

150 LB

Dimensions [inches]

A

B

C

ø

D

ø

E

ø

F

ø

G

ø

H I J

No. of

bolts

Diam.

of

bolts

65 5” 0.5 8.86 5.5 5.3 7.4 8.5 10 8 3/4 1.53 7.33

65 6” 0.6 8.86 6.6 6.4 8.3 9.5 11 8 3/4 1.53 7.33

65 8” 0.6 8.86 8.6 8.4 10.6 11.75 13.5 8 3/4 1.53 7.33

80 4” 0.5 8.86 4.5 4.3 6.2 7.5 9 8 5/8 1.89 6.97

80 5” 0.5 8.86 5.5 5.3 7.4 8.5 10 8 3/4 1.89 6.97

80 6” 0.6 8.86 6.6 6.4 8.3 9.5 11 8 3/4 1.89 6.97

80 8” 0.6 8.86 8.6 8.4 10.6 11.75 13.5 8 3/4 1.89 6.97

80 10” 0.6 8.86 10.2 9.8 12.2 14.25 16 12 7/8 1.89 6.97

105 6” 0.6 8.86 6.6 6.4 8.3 9.5 11 8 3/4 2.32 6.54

105 8” 0.6 8.86 8.6 8.4 10.6 11.75 13.5 8 3/4 2.32 6.54

105 10” 0.6 8.86 10.2 9.8 12.2 14.25 16 12 7/8 2.32 6.54

150 8” 0.6 8.86 8.6 8.6 10.6 11.75 13.5 8 7/8 2.99 5.87

150 10” 0.6 8.86 10.1 9.8 12.6 14.25 16 12 7/8 2.99 5.87

150 12” .06 8.86 12.6 12.6 14.6 17 19 12 7/8 2.99 5.87

Page 28: Page 1/1 Dry installed Chopperpump

landiainc.com

Prepared by: BNV/GB Approved by: KSK/TM

Issued on: 1 June 2018 Rev. date: 21. March 2021

Data Sheet CJ00B.C13

Page 8 of 8

OVERALL DIMENSIONS St. steel CONNECTION TO ANSI FLANGE FOR MPTK-I/MPTKR-I

Pump

series

Coupling

foot

ANSI

150 LB

Dimensions [inches]

A

B

C

ø

D

ø

E

ø

F

ø

G

ø

H

No.

Of

bolts

Diam.

of

bolts

65 3” 0.5 5.9 3 2.8 4.8 6 7.5 4 5/8

65 4” 0.5 5.9 4.5 4.3 6.2 7.5 9 8 5/8

80 65/80 3” 0.5 5.9 3 2.8 4.8 6 7.5 4 5/8

80 65/80 4” 0.5 5.9 4.5 4.3 6.2 7.5 9 8 5/8

80 65/80 5” 0.5 5.9 5.5 5.3 7.4 8.5 10 8 3/4

80 65/80 6” 0.5 5.9 6.6 6.4 8.3 9.5 11 8 3/4

105 105 4” 0.5 5.9 4.5 4.3 6.2 7.5 9 8 5/8

105 105 5” 0.5 5.9 5.5 5.3 7.4 8.5 10 8 3/4

105 105 6” 0.5 5.9 6.6 6.4 8.3 9.5 11 8 3/4

We reserve the right to make technical changes.

Page 29: Page 1/1 Dry installed Chopperpump

CJ01A.C01

Service instructions, pump type MPTK-I / MPTKR-I Page 1/9

Landia Inc. Issued on: 01 March 1997

Cary, NC 27513 Rev. date: 22 November 2017

Executed by: AJ/BNV Accepted by: SL/KT

Content Introduction ..................................................................................................................................................... 2 IMPORTANT ................................................................................................................................................. 2 Service/repair .................................................................................................................................................. 3

Installation ....................................................................................................................................................... 4 Rating plate ..................................................................................................................................................... 4 Power connection ............................................................................................................................................ 4

Capacity .......................................................................................................................................................... 5 Fitting the front plate....................................................................................................................................... 6 Fitting the back plate ....................................................................................................................................... 7 Installing the knives ........................................................................................................................................ 7

Inspection ........................................................................................................................................................ 8 Dismounting/Mounting of unit ....................................................................................................................... 8

Page 30: Page 1/1 Dry installed Chopperpump

CJ01A.C01

Service instructions, pump type MPTK-I / MPTKR-I Page 2/9

Landia Inc. Issued on: 01 March 1997

Cary, NC 27513 Rev. date: 22 November 2017

Executed by: AJ/BNV Accepted by: SL/KT

Introduction The type is a dry installed pump.

By means of different equipment a great number of different pumping requirements can be met.

The pumping takes place by means of an electric motor; a pump casing with an impeller is mounted on the

motor.

The oil filled oil chamber between motor and impeller provides cooling and lubrication of the mechanical

seals.

The sealing system consists of two mechanical seals. The exterior seal separates the medium from the oil

chamber, the interior seal separates the oil from the motor casing.

Application

This dry installed pump is to be applied for pumping of liquids with a high or a low dry matter content, like e.g.

thick manure and highly polluted wastewater. The pump is only to be applied dry installed in connection with

application at e.g. effluent treatment plants, in industry and in agriculture. If the pump is to be applied for other

purposes, contact Landia for advice.

IMPORTANT Please note the following points:

▪ Only a certified electrician is allowed to connect the unit.

▪ Prior to installation and start up, check that the equipment, such as hoses, pipes and pipe

branches, is mounted correctly on the pump.

▪ Prior to the first start of the pump, the pump shaft must be rotated manually. This

also applies if the pump has not been in operation for a longer period.

▪ The pump must be dry installed but can be placed outside without protection as the

motor is splashproof. The motor is not to be wrapped in plastic film etc.

▪ Prior to service/repair of the pump it is imperative that the electrical connection of the

pump is switched off or locked out.

▪ Prior to dismounting the pump, the sluice valve on the pressure side and on the inlet

side must be completely closed.

Page 31: Page 1/1 Dry installed Chopperpump

CJ01A.C01

Service instructions, pump type MPTK-I / MPTKR-I Page 3/9

Landia Inc. Issued on: 01 March 1997

Cary, NC 27513 Rev. date: 22 November 2017

Executed by: AJ/BNV Accepted by: SL/KT

Service/repair To maintain a high operating safety and a long service life without unnecessary and expensive repair it is

important from the beginning to execute regular and preventive service. Maintenance should be executed

according to the intervals stated in the manual. Always follow the instruction carefully and only apply the parts

described by Landia in the spare parts list. We can refer you to a service partner in your territory.

Please note

If spare parts not identical to the ones recommended are used at service/repair, the guarantee from Landia

will be void. Spare parts can be ordered at Landia or your local distributor.

For major repairs at a special workshop please contact:

Head Office: US subsidiary:

LANDIA A/S Landia Inc

Industrivej 2 111 Triangle Trade Drive

DK-6940 Lem St. Cary, NC 27513

Tel.: + 45 97 341244 Phone: 919 466 0603

Fax: + 45 97 341698 Fax: 919 460 1666

E-mail: [email protected] e-mail: [email protected]

www.landia.dk

Landia is represented by local distributors worldwide, please call for further information.

Page 32: Page 1/1 Dry installed Chopperpump

CJ01A.C01

Service instructions, pump type MPTK-I / MPTKR-I Page 4/9

Landia Inc. Issued on: 01 March 1997

Cary, NC 27513 Rev. date: 22 November 2017

Executed by: AJ/BNV Accepted by: SL/KT

Installation At installation it must be secured that the pump can be removed from the pipe system in case of breakdown,

service etc. Therefore, block valves must be installed on the pressure and on the inlet side of the pump,

unless the pipe system can be emptied in another way. Besides, it must be secured at fixing to the concrete

foundation that the pump can be lifted in service situations. By means of a motor support foot, the console of

the pump is relieved - Fig. 1. At pump installations in piping systems compensators must be applied since

vibrations and temperature fluctuations will influence the piping system.

At installation the drainage hole in the receiver and the condensation hole in the motor must turn downwards

– Fig. 4.

Rating plate

IP: Cage class

F: Insulation class F

3~mot.nr.: 3 phased motor

IM: Building form

cos : Power factor

kg: Weight of motor without pump

kW: Max. shaft power

V: Mains voltage

A: Nominal power consumption

min: Motor revolutions per minute

kW,V,A and min-1 for 50 Hz and 60 Hz respectively.

The final two lines state the allowed voltage intervals with power

consumption at 50 Hz and 60 Hz resp.

Power connection Every pump is equipped with the above mentioned rating plate with technical motor data. It must be verified

that the other electrical parts correspond to the motor data. For each pump there is an electrical diagram. A

protective motor switch must be applied at connection of the pump to the mains.

Only a certified electrician is allowed to connect the unit.

Fig. 1

Motor base

Page 33: Page 1/1 Dry installed Chopperpump

CJ01A.C01

Service instructions, pump type MPTK-I / MPTKR-I Page 5/9

Landia Inc. Issued on: 01 March 1997

Cary, NC 27513 Rev. date: 22 November 2017

Executed by: AJ/BNV Accepted by: SL/KT

Capacity The capacity of the pump will always depend on the consistency of the medium.

To obtain the highest capacity possible with as low motor power as possible it is important that the diameters

of the pump pipes are as large as possible. It is also important to avoid sharp curves. Large pipe dimensions

are especially important in connection with long pumping distances. At pump installations in piping systems

compensators must be applied since vibrations and temperature fluctuations will influence the piping system.

The pumps are equipped with open impellers especially suited for liquids with large particles, like e.g. raw

wastewater, manure and industry applications.

For difficult mediums with e.g. a high dry matter content or large impurities which make up a risk for

blocking, the pumps can be supplied with a knife system. The knife system which is placed in the inlet port

consists of one (or three) fixed and two rotating knives. The knives comminute large impurities in the

medium in order to ease the pumping. They are ideal for comminuting e.g. straw, shreds, paper, fish etc.

The capacity of the pump will be reduced if the edge of the guide trace on the front and back plates is rounded

and worn or if deep furrows occur in the guide traces. If you have any doubts or questions, please contact Landia

for our advice.

Pump casing w. knife system Fig. 2

Pump casing w. extended knife system Fig. 3

Page 34: Page 1/1 Dry installed Chopperpump

CJ01A.C01

Service instructions, pump type MPTK-I / MPTKR-I Page 6/9

Landia Inc. Issued on: 01 March 1997

Cary, NC 27513 Rev. date: 22 November 2017

Executed by: AJ/BNV Accepted by: SL/KT

Fitting the front plate

A. Knife with tightening pin

B. Front plate

C. Guide trace

D. Pump casing

E. Outlet

Important:

The front plate (B) of the pump casing (D) is designed with a guide trace (C). The guide trace has to be

placed like shown on the above photo, regardless of how the outlet of the pump is turned.

A

C

B

D

E

Page 35: Page 1/1 Dry installed Chopperpump

CJ01A.C01

Service instructions, pump type MPTK-I / MPTKR-I Page 7/9

Landia Inc. Issued on: 01 March 1997

Cary, NC 27513 Rev. date: 22 November 2017

Executed by: AJ/BNV Accepted by: SL/KT

Fitting the back plate

A. Back plate

B. Guide trace

C. Pump casing

D. Outlet

Important:

The front plate (B) of the pump casing (D) is designed with a guide trace (C). The guide trace has to be

placed like shown on the above photo, regardless of how the outlet of the pump is turned.

Installing the knives

A. Fixed knife

B. Tightening pin

C. Rotating knife

D. Bolt

If the tightening pin in the fixed knife is missing, the pin/knife must be replaced.

When the fixed and rotating knives are replaced, make sure that the shaft can rotate without the rotating

knives touching the fixed knife/knives. If this is not the case, the fixed knife/knives must be adjusted with

shims.

Shim

A

C

B

D

A

C

B

D

Page 36: Page 1/1 Dry installed Chopperpump

CJ01A.C01

Service instructions, pump type MPTK-I / MPTKR-I Page 8/9

Landia Inc. Issued on: 01 March 1997

Cary, NC 27513 Rev. date: 22 November 2017

Executed by: AJ/BNV Accepted by: SL/KT

Inspection Regular inspection will ensure the pump a long service life at low costs. Every 6 months or more often

depending on the operation conditions, the impeller, the oil quantity, the motor casing and the knife system,

if any, should be inspected. The oil must be changed at least once a year or according to the service

interval for this particular unit indicated on the front page of this instruction.

If the tightening pin of the fixed knife is lacking, the pin and the knife must be exchanged.

If large quantities of oil/liquid seep out of the drainage hole in the receiver – Fig. 4, the mechanical shaft

seals of the pump should be inspected. When the knife system has been replaced, the bolt must be tightened

with a tightening torque acc. to the table on page 9.

The oil is controlled by dismounting the upper oil plug pos. A. For

pumps with pressure equalization, pos. F is dismounted. The oil has

to be clean and the level must reach the level of the upper plug pos.

A when the pump is in a horizontal position, standing on its feet. If

the oil is dirty, it must be changed and the two mechanical seals

must be controlled and changed, if necessary. Oil type: see spare

parts list.

The oil is drained off at oil plug pos. B and is filled at oil plug pos. A.

For pumps with pressure equalization, oil is filled at pos. F.

Pos. C is a drainage hole, pos. D is a condensation hole and pos. G is

an inspection hole.

If the pump is equipped with an oil collector, a plug is placed in

drainage hole C. The oil in the collector is drained by removing the

plug in drainage hole C. If the oil collector is full, the oil comes out

of inspection hole G.

For pumps equipped with pressure equalization, the filter pos. E

must be cleaned or replaced in connection with maintenance to

avoid plugging.

Dismounting/Mounting of unit NOTE: a major repair should take place at a workshop which is specialised in this type of repair.

Below please find some general conditions regarding dismounting/mounting of the pump.

The drawing attached to the spare parts list shows the construction of the unit. Not all parts can/should be

dismantled, e.g. do not press the rotor off the shaft.

When dismounting the unit, handle the mechanical seals with care; they are not shock resistant.

Prior to re-mounting, all sealing surfaces must be cleaned, all O-rings must be checked and changed, if

necessary. Adhesive substance (Loctite 243) must be applied on all bolt joints, except on the separation bolts.

All bolts must be tightened with a torque wrench as specified in the table below.

Fig. 4

G

A

B C D

E

F

Fig. 5

Page 37: Page 1/1 Dry installed Chopperpump

CJ01A.C01

Service instructions, pump type MPTK-I / MPTKR-I Page 9/9

Landia Inc. Issued on: 01 March 1997

Cary, NC 27513 Rev. date: 22 November 2017

Executed by: AJ/BNV Accepted by: SL/KT

Bolt sizes

Quality 10.9 – 12.9

Steel

Quality A4 kl. 80

St.steel

5 mm 3 ft-lbft

6 mm 10 ft-lbft 7 ft-lbft

8 mm 25 ft-lbft 18 ft-lbft

10 mm 49 ft-lbft 35 ft-lbft

12 mm 85 ft-lbft 60 ft-lbft

16 mm 118 ft-lbft 101 ft-lbft

After the bearing flange has been mounted, the axial clearance must be controlled acc. to the table below.

Pump size 1800 rpm. Acceptable clearance Pump size 3600 rpm. Acceptable clearance

50 0.01 ± 0.002 inch 50 0.02 ± 0.002 inch

65 0.02 ± 0.002 inch 65 0.031 ± 0.002 inch

80 0.02 ± 0.002 inch 80 0.051 ± 0.002 inch

105 0.031 ± 0.002 inch

150 and 105 22/30 kW 0.051 ± 0.002 inch

When mounting the mechanical shaft seals, be aware that

these are precision products and that they should be handled

with care. The slide faces must be protected during the

installation.

Push the stationary sealing ring into place.

Be careful not to damage the slide face during the mounting.

The rotating sealing ring is put over the shaft. To ease the mounting put soap water on the interior side of the

rubber bellows as well as on the shaft. Do not apply silicone, PTFE lubricants or oil as they will prevent the

rubber bellows from sticking to the shaft. Mounting arbor should be used. Put the locking ring on the shaft

and press together the seal until the locking ring snaps into the locking ring groove. Check the seal by turning

the motor shaft. Oil is filled in the oil chamber. During the filling, the pump must be in a horizontal position.

Oil quantity: see spare parts list. The oil must reach the level of pos. A page 8.

Repair of the surface coating is necessary prior to operation start. See instruction for maintenance of surface

coating.

We reserve the right to technical alterations.

Translated from Danish

Page 38: Page 1/1 Dry installed Chopperpump

Quickguide for MPTK

Lifting point

Dry testRotate shaft before start-up

Page 39: Page 1/1 Dry installed Chopperpump

Rating plate

Model W L

mm inch mm inch

MPTK-I 50 1250 49 1350 53

MPTK-I 65 1350 53 1500 59

MPTK-I 80 1400 55 1600 63

MPTK-I 105 1450 57 1800 70

MPTK-I 150 1600 63 1850 72

Service area

Recommended platform size

Page 40: Page 1/1 Dry installed Chopperpump

Horisontal F = 0 N.(consider compensator)

Vertical F = 0 N.(consider compensator)

Pump must not carry any load from piping

Piping must be aligned

Rating plate

Page 41: Page 1/1 Dry installed Chopperpump

landiaworld.comDK92A.C01 21 January 2020 CML/KSK

MotorMoteur

TP1(T1)TP2(T2)

Tripping enhedAuslöserTripping deviceDispositif de déclenchement

Spænding max. 2,5 VSpannung max. 2,5 VVoltage max. 2,5 VTension max. 2,5 V

KlemrækketilslutningKlemmbrettschaltungenTerminal Board ConnectionsCouplages sur la planche à bornes

Stjerne-trekant tilslutningSterndreieckschalteranschlussStar-delta switch connectionConnexion du commutateur étoile-triangle

Ved brug af stjerne-trekantstarter tilsluttes efter dennes diagram.Bei Sterndreieckschalter ohne Brücken Anschluss nach Schema des Schalters.For star-delta switches without jumpers connection is as indicated on the schematic of the switch.En cas de commutateur étoile-triangle sans ponts, connexion selon le schéma au commutateur.

Motorer med termistorerMotoren mit thermischem WicklungsschutzMotors with Thermal Winding ProtectionMoteurs avec protection thermique par enroulement

Forbindelsen implementeres ifølge forbindelsesdiagrammet for tripperenheden.Die Verbindung erfolgt nach dem Anschlussplan der Auslösevorrichtung.The connection is implemented as per the connection diagram of the tripping device.La connexion est implémentée selon le schéma de connexion du dispositif de déclenchement.

TrekantkoblingDelta connectionDreieckschaltungBranchement en triangle

StjernekoblingStar connectionSternschaltungBranchement en étoile

Page 42: Page 1/1 Dry installed Chopperpump

CK04A.C01

Service Instruction Page 1/2

Executed by: HL/CML Issued on: 10 August 2000 Accepted by: KSK Rev. date: 26 August 2020

Table for Oil Amount - Pumps

DG-I

Seal Control Frequency Converter

Food Industry

Type Pump Casing Motor Series Rpm CRB Multi 15W-40

(9380001)

Hyspin HVI 15

(9380011)

Hyspin HVI 46D

(9380009)

CRB Multi 15W-40

(9380001)

Whitemore WOM 65

(9380015)

DG-I

50 71

1500

0.7 l 0.7 quarts

-

0.7 l / 0.7 quarts

65 80/90 1.5 l

1.6 quarts 1.5 l / 1.6 quarts

DG-I DGR-I DGER-I

65 100 1.5 l

1.6 quarts 1.5 l / 1.6 quarts

80 100/112 2.4 l

2.5 quarts 2.4 l / 2.5 quarts

105 132/160/180 3.8 l

4.0 quarts 3.8 l / 4.0 quarts

DG-I 150

160 3.8 l

4.0 quarts 3.8 l / 4.0 quarts

180 6.5 l

6.8 quarts 6.5 l / 6.8 quarts

DG-I 50 80/90/100

3000 -

0.8 l / 0.9 quarts

DG-I DGR-I

65 112 1.1 l / 1.2 quarts

132/160 1.7 l / 1.8 quarts

80 160 2.4 l / 2.5 quarts

180 4.0 l / 4.2 quarts

Page 43: Page 1/1 Dry installed Chopperpump

CK04A.C01

Service Instruction Page 2/2

Executed by: HL/CML Issued on: 10 August 2000 Accepted by: KSK Rev. date: 26 August 2020

MPTK-I

Seal Control Frequency Converter

Food Industry

Type Pump Casing Power [kW]

Rpm CRB Multi 15W-40

(9380001)

Hyspin HVI 15

(9380011)

Hyspin HVI 46D

(9380009)

CRB Multi 15W-40

(9380001)

Whitemore WOM 65

(9380015)

MPTK-I 50

-

1500

0.6 l 0.6 quarts

-

0.6 l / 0.6 quarts

MPTK-I MPTKR-I

65 1.3 l

1.4 quarts 1.3 l / 1.4 quarts

MPTK-I MPTKR-I MPTK-GI 80

2.3 l 2.4 quarts

2.3 l / 2.4 quarts

MPTK-I Ex. 3.4 l

3.6 quarts 3.4 l / 3.6 quarts

MPTK-I MPTKR-I MPTK-GI MPTKR-GI 105

3.4 l 3.6 quarts

3.4 l / 3.6 quarts

MPTK-I Ex. MPTKR-I Ex.

5.8 l 6.1 quarts

5.8 l / 6.1 quarts

MPTK-I MPTK-GI

150

18,5 4.0 l

4.2 quarts 4.0 l / 4.2 quarts

22.0/30.0 5.5 l

5.8 quarts 5.5 l / 5.8 quarts

MPTK-I Ex. - 8.5 l

9.0 quarts 8.5 l / 9.0 quarts

MPTK-I 50

-

3000 -

0.7 l / 0.7 quarts

MPTK-I MPTKR-I

65 1.3 l / 1.4 quarts

MPTK-I MPTKR-I

80 15.0/18.5 2.2 l / 2.3 quarts

22.0/30.0 4.2 l / 4.4 quarts

Page 44: Page 1/1 Dry installed Chopperpump

CK86A.C01

Service Instruction Page 1/1

Executed by: HL/CML Issued on: 19 maj 2016 Accepted by: KSK Rev. date: 26 August 2020

Conversion table

Oil

CASTROL Alpha SP 100 Alpha SP 220 Whitemore WOM 65 CRB Multi 15W-40 Hyspin HVI 15 Vario HDX Nevastane EP 100 Alphasyn GS 220

MOBIL Mobilgear 627 Mobilgear 630 Whiterex 318E Delvac MX15W-40 Mobil DTE 10 Excel 15

No alternatives

Q8 Goya 100 Goya 220 Medicinal White Oil 68 T 500 15W-40 Haydn 15

SHELL Omala 100 Omala 220 Ondina 933 Rimula X 15W-40 Tellus T 15

STATOIL LoadWay EP 100 LoadWay EP 220 MedicWay M 68 PowerWay 15W-40 HydraWay HM 15

TEXACO Meropa 100 Meropa 220 White Oil Pharmaceuticals 190

Ursa Super LA 15W-40

Rando HDZ 15

TOTAL Total Carter 100 Total Carter 220 Total Finavestan A360B

Fina Kappa Turbo DI 15W-40

Equivis ZS 15

Grease

BEL RAY Bel Ray 50-2

CASTROL Tribol GR 4747/220-2 HT

MOBIL Mobilgrease FM 222

Q8 Rubens WB

SHELL SHELL GADUS S3 V220C 2

TEXACO Anderol 783-2

TOTAL TOTAL NEVASTANE XMF 2

Lubricants applied and recommended by Landia A/S are marked with grey in the above tables. The conversion tables state the names of equivalent lubricants from other oil companies. Generally, mixing of different types of grease should be avoided either by replacing all the grease or frequent lubrication, so the grease is quickly replaced. The grease types mentioned above are mixable.

Page 45: Page 1/1 Dry installed Chopperpump

Motor date

3 x 460 V 60 Hz

Rated Reated ms. No.of RPM Voltage Voltage Power for Direct Cos phi Efficiencypower power poles Delta Star 3x460 V start

HP kW A %

2,4 1,8 80 2 3340 265 460 3,4 24 0,85 823,6 2,6 80 2 3460 265 460 4,9 37 0,85 834,9 3,6 90 2 3470 460 6,5 40 0,83 85,56,5 4,8 100 2 3500 460 8,9 68 0,8 879 6,6 100 2 3430 460 11,5 63 0,85 85,7

12,2 9 112 2 3480 460 15 99 0,86 8717,9 13 132 2 3480 460 20,5 144 0,9 8824,5 18 160 2 3530 460 28 199 0,9 89,630,2 22 160 2 3520 460 33 238 0,92 90,535,4 26 180 2 3535 460 38,5 270 0,92 9248,9 36 180 2 3550 460 53 392 0,92 9360 44 180 2 3545 460 65,5 459 0,91 9373 54 180 2 3535 460 80,5 604 0,9 93,7

0,9 0,65 71 4 1710 265 460 1,8 8 0,66 711,2 0,9 71 4 1710 265 460 2,3 11 0,68 741,8 1,3 80 4 1720 265 460 2,8 15 0,77 772,4 1,8 80 4 1710 265 460 3,7 21 0,77 803,6 2,6 90 4 1720 265 460 5,3 34 0,75 814,9 3,6 100 4 1730 460 7 48 0,77 846,5 4,8 100 4 1735 460 9 66 0,78 859 6,6 112 4 1745 460 11 72 0,88 86

12,2 9 132 4 1750 460 15,5 93 0,84 8717,9 13 132 4 1755 460 22 152 0,84 88,424,5 18 160 4 1765 460 29,5 224 0,86 89,430,2 22 160 4 1760 460 36 241 0,85 9035,4 26 180 4 1765 460 43,5 283 0,83 90,548,9 36 180 4 1765 460 59 413 0,84 91,560 44 180 4 1770 460 70 490 0,85 92,573 54 180 4 1770 460 85,5 599 0,85 93

6,5 4,8 112 6 1155 460 9,7 58,2 0,78 80

0,9 0,65 80 8 850 265 460 2,2 8 0,54 68

1,2 0,9 90 8 855 265 460 3 11 0,57 681,8 1,3 100 8 855 265 460 3,4 15 0,64 752,4 1,8 100 8 850 265 460 4,3 20 0,67 783,6 2,6 112 8 865 265 460 6 27 0,71 764,9 3,6 112 8 855 460 7,9 34 0,73 786,5 4,8 132 8 860 460 10,5 42 0,73 79,59 6,6 132 8 865 460 13,5 61 0,74 82

12,2 9 160 8 875 460 17,5 77 0,78 8317,9 13 160 8 870 460 25 113 0,77 85

Landia.dkPrepared by GB

Accepted by: SL Rev. date: 25 oktober 2017

CK00A.C03

Page 1/1

Issued on: 27. aug. 1993

Page 46: Page 1/1 Dry installed Chopperpump

Motor Date

3 x 460 V 60 Hz IE2

Rated Reated ms. No.of RPM Voltage Voltage Power for Direct Cos phi Efficiencypower power poles Delta Star 3x460 V start

HP kW A %

2,4 1,8 90 2 3510 265 460 2,9 31 0,88 843,6 2,6 90 2 3470 265 460 4,3 31 0,88 85,54,9 3,6 100 2 3525 460 6,45 48 0,8 87,56,5 4,8 100 2 3510 460 7,9 56 0,86 88,59 6,6 112 2 3490 460 10,5 84 0,88 89,5

12,2 9 132 2 3505 460 14 87 0,9 89,517,9 13 160 2 3550 460 20 146 0,91 90,924,5 18 160 2 3530 460 27,3 172 0,91 90,830,2 22 160 2 3525 460 37,5 262 0,92 91,635,9 26 180 2 3545 460 39,5 237 0,9 91,748,9 36 180 2 3550 460 54 324 0,91 92,460,3 44 180 2 3545 460 65,5 445 0,91 93

0,9 0,65 80 4 1725 265 460 1,24 8 0,81 81,21,2 0,9 80 4 1725 265 460 1,65 11 0,82 82,51,8 1,3 90 4 1735 265 460 2,4 16 0,81 842,4 1,8 100 4 1735 265 460 3,4 38 0,79 843,6 2,6 100 4 1755 265 460 4,9 38 0,76 87,54,9 3,6 112 4 1750 460 6,5 60 0,79 87,56,5 4,8 112 4 1760 460 7,7 60 0,87 89,59 6,6 132 4 1745 460 10,5 121 0,88 89,5

12,2 9 132 4 1770 460 15 121 0,83 90,817,9 13 160 4 1765 460 22,5 169 0,8 91,324,5 18 180 4 1775 460 28,5 302 0,85 92,530,2 22 180 4 1775 460 35 302 0,86 92,435,9 26 180 4 1780 460 42 302 0,84 93

0,9 0,65 80 6 1145 265 460 1,5 7 0,69 79

1,2 0,9 90 6 1150 265 460 1,95 10 0,72 801,8 1,3 100 6 1165 265 460 2,6 14 0,78 812,4 1,8 112 6 1165 460 3,4 47 0,8 833,6 2,6 112 6 1165 460 5 47 0,79 834,9 3,6 112 6 1165 460 6,8 47 0,79 846,5 4,8 132 6 1165 460 8,7 46 0,79 87,59 6,6 160 6 1165 460 11,5 88 0,8 89,5

12,2 9 160 6 1170 460 15,5 88 0,81 89

17,9 13 180 6 1175 460 22 215 0,83 90,3

24,5 18 180 6 1175 460 29,5 215 0,85 90,230,2 22 180 6 1175 460 35,5 234 0,85 91,7

Landia.dkPrepared by PEG

Rev. date: 25. oktober. 2017

CK11A.C03

Page 1/1

Issued on: 09. may 2014Accepted by: KSK