pb eif system details - external wall insulationparex vented track 363 g1.02 parex standard system...
TRANSCRIPT
ContentsSubject Detail Page
General Construction G1.02 Parex Standard System components .3
G2.01 Insulation board application . . . . . . .3
G3.01 Preliminary mesh application . . . . . . 4
G4.01 Inside corner . . . . . . . . . . . . . . . . . . . .4
G5.01 Outside corner . . . . . . . . . . . . . . . . . . .4
Expansion Joints E1.01 Track expansion joint . . . . . . . . . . . . .5
E2.01 Backwrapped expansion joint . . . . . .5
E3.01 Building isolation joint . . . . . . . . . . . .5
E4.01 Dissimilar substrates . . . . . . . . . . . . . .6
E5.01 Inside Corner at dissimilar substrates .6
E6.01 Wood framed sill . . . . . . . . . . . . . . . . .7
E7.01 Wood framed floor line . . . . . . . . . . .7
Terminations T1.01 Termination above pavement . . . . . . .8
T2.01 Termination above grade . . . . . . . . . .8
T3.01 Base coat below grade . . . . . . . . . . . .9
T6.01 Termination at balcony deck . . . . . . .9
Windows W1.01 Backwrapped jamb . . . . . . . . . . . . .10
W2.01 Seal tape termination at flush
/ projecting jamb . . . . . . . . . . . . . . .10
W3.01 Insulated jamb return . . . . . . . . . . .10
W4.01 Uninsulated jamb return . . . . . . . . .11
W5.01 Head with vented track 363 . . . . . .11
W6.01 Insulated head return . . . . . . . . . . .11
W7.02 Uninsulated head return . . . . . . . . .12
W8.03 Rough sill edge
wrapped prior to flashing . . . . . . . .12
W8.04 Backwrapped termination at sill . . .12
Roof Line R1.03 Parapet . . . . . . . . . . . . . . . . . . . . . . . .13
R1.04 Parapet coated prior to flashing . . .13
R2.01 High wall at low roof . . . . . . . . . . . .14
R3.01 Gravel stop . . . . . . . . . . . . . . . . . . . . .14
R4.01 Insulated soffit . . . . . . . . . . . . . . . . . .15
R5.03 Termination at soffit . . . . . . . . . . . . .15
R6.02 Intersection of roof cornice
at standard system wall . . . . . . . . . .16
R6.02B Intersection of roof cornice
at standard system wall . . . . . . . . .16
Aesthetic Features A1.02 Aesthetic groove / reveal . . . . . . . . .17
A2.01 Small aesthetic band / protection . .17
Penetrations P1.01 Fixture attachment . . . . . . . . . . . . . .18
P2.02 Scupper . . . . . . . . . . . . . . . . . . . . . . . .18
P3.01 Removable appliance . . . . . . . . . . . .18
The drawings, and any related notes,or text contained thereon are basedupon typical requirements of Parex,Incorporated exterior insulation andfinish systems and are published strictlyas a guide for architectural andconstruction industry professionals toillustrate typical or general designconditions.
These details are not to be used bythemselves, and do not constitute designinstructions for PB EIFS application.These details must be used in conjunctionwith Parex, Incorporated current productspecifications, product data sheets, andapplication instructions.
Any details shown are strictly for thepurpose of illustrating typical PB EIFSdesign applications. Any other materialsshown in any details are incidental tothe details, and are included only forclarity of the PB EIFS system detail.Please consult with the manufacturersand/or suppliers of any separate materialsfor their product specifications andapplications instructions.
Where site or design conditions notshown in these details are present, orany unusual design is involved, pleaseconsult with Parex, Incorporated technicaldepartment for assistance.
PAREX, INCORPORATED DOES NOTWARRANT THE FITNESS OF SUITABILITYOF THESE DETAILS FOR CONSTRUCTION,OR ASSUME ANY LIABILITY FOR USE OFTHESE DETAILS. IT IS THE SOLERESPONSIBILITY OF ANY ARCHITECTURALOR CONSTRUCTION INDUSTRYPROFESSIONAL TO APPLY THEIRPROFESSIONAL KNOWLEDGE INUTILIZING THE INFORMATIONCONTAINED IN THESE DETAILS.
PB EIF System DetailsCSI SECTION 07 24 00
A. FIRST COURSE OF EPS IS HALFWIDTH TO ALLOW FOR OFFSET OFHORIZONTAL JOINTS OF EPSINSULATION BOARD ANDSHEATHING BOARD
B. VERTICAL OFFSET OF EPS INSULATIONBOARD AND SHEATHING BOARD JOINTS SHOULD TYPICALLY BE NO LESS THAN 12”
- APPLY BOARDS OVER DRY SUBSTRATES IN A RUNNINGBOND PATTERN TYPICALLY LONG EDGE HORIZONTALLY.STAGGER VERTICAL JOINTS IN SUCCESSIVE COURSES.
- INTERLOCK ENDS AT INSIDE AND OUTSIDE OF CORNERS
- ABUT BOARDS TIGHTLY AT JOINTS WITHIN AND BETWEENEACH COURSE TO PRODUCE A FLUSH, CONTINUOUSLY EVENSURFACE WITHOUT GAPS. FILL ANY GAPS LARGER THAN 3/32”WITH INSULATION BOARD SLIVERS
- ALLOW THE ADHESIVE TO FORM A POSITIVE BOND, AMINIMUM OF 24 HOURS, OR LONGER AS REQUIRED BYCONDITIONS, SHALL ELAPSE PRIOR TO THE RASPING OFTHE INSULATION BOARD.
- LEVEL ANY IRREGULARITIES IN THE SURFACE OF THEINSULATION BOARD.
A = 12”B = 8” Min.
PAREX TRACK 363 OR BACKWRAPAS IN T2.01
SHEATHING SUBSTRATE (HIDDEN LINES INDICATE SHEATHING LOCATION
UNDER EPS INSULATION BOARD)
FOUNDATION
G2.01 INSULATION BOARD APPLICATION
(SHEATHED SUBSTRATES)
A
B
FRAMING
SUBSTRATE
PAREX ADHESIVE 121
EXPANDED POLYSTYRENE ASTM C-578 TYPE IINSULATION BOARD
PAREX REINFORCING MESH EMBEDDEDIN PAREX BASE COAT
PAREX BASE COAT
PAREX FINISH
PAREX VENTED TRACK 363
G1.02 PAREX STANDARD SYSTEM COMPONENTS
PB EIF System Details
SEE ALSO INSIDE CORNERDETAIL G4.01
BACKWRAP AT HEAD ORUSE PAREX VENTEDTRACK 363 AS APPLICABLE.SEE ALSO DETAILS W5.01- W7.02
INTERLOCKCORNERS OF EPS
SEE ALSOOUTSIDE CORNERDETAIL G5.01
NOTE EPS BOARD JOINTSDO NOT ALIGN WITHCORNERS OF OPENINGS
9” X 12” (23 X 30 cm) SHORTDETAIL MESH 356 EMBEDDEDDIAGONALLY IN BASE COATAT CORNERS
BACKWRAP OR USE PAREXTRACK SEE ALSO DETAILST101 AND T201
G3.01 PRELIMINARY MESH APPLICATION
PAREX REINFORCING MESHDOUBLE WRAPPED ANDEMBEDDED IN BASE COAT
PAREX FINISH
EPS
PAREX ADHESIVE
SUBSTRATE
G4.01 INSIDE CORNER
SUBSTRATE
PAREX ADHESIVE
EPS
PAREX REINFORCING MESHDOUBLE WRAPPED ANDEMBEDDED IN BASE COAT
PAREX FINISH
G5.01 OUTSIDE CORNER
PAREX VENTEDTRACK 363 FASTENEDTO SUBSTRATE
E.P.S.
PAREX REIFORCINGMESH EMBEDDED INBASE COAT. NOTEOVERLAP ONTO TRACK
PAREX BASE COAT
PAREX FINISH
CLOSED CELL POLYETHYLENEBACK AND ELASTOMERICSEALANT
3/4” (19 mm)MIN.
(AXONOMETRIC PICTORIAL)
E1.01 TRACK EXPANSION JOINT
MESH AT EPS BOARD EDGESFULLY EMBEDDED AND COVEREDWITH PAREX BASE COAT
PAREX SHORT DETAIL MESH356 BACKWRAPPED
MESH OVERLAPAT DETAIL MESH. 2 1/2” (63 mm) MIN.
EPS
PAREX BASE COAT
PAREX FINISH
CLOSED CELL POLYETHYLENEBACKER AND ELASTOMERICSEALANT, WITH SEALANTMANUFACTURER’S RECOMMENDEDPRIMER.
3/4” (19 mm) MIN.
(AXONOMETRIC PITORIAL)
2 1/2” (63 mm) MIN.
E2.01 BACKWRAPPED EXPANSION JOINT
E3.01 BUILDING ISOLATION JOINT
PAREX ADHESIVE
E.P.S.
PAREX BASE COATWITH REINFORCING
MESH EMBEDDED
PAREX FINISH
SEE DETAILS E1.01AND E2.01 FOR
EXPANSION JOINT
PB EIF System Details
E5.01 INSIDE CORNER AT DISSIMILAR SUBSTRATES
PAREX FINISH
PAREX BASE COAT WITHREINFORCING MESH EMBEDDED
E.P.S.
PAREX ADHESIVE
PAREX SHORT DETAIL MESH BACKWRAPPED ANDEMBEDDED IN BASE COAT OR USE PAREX TRACK
CLOSED CELL POLYETHYLENE BACKER ANDELASTOMERIC SEALANT, WITH SEALANTMANUFACTURER’S RECOMMENDED PRIMER.JOINT WIDTH MINIMUM 3/4” (19 mm).
PAREX ADHESIVE
E.P.S.
PAREX BASE COATWITH REINFORCING
MESH EMBEDDED
PAREX FINISH
SEE DETAILS E1.01AND E2.01 FOREXPANSION JOINT
E4.01 DISSIMILAR SUBSTRATES
WOOD FRAMING
SHEATHING
PAREX ADHESIVE
PAREX FINISH
WOOD SILL
SEE DETAIL E1.01 OR E2.01FOR EXPANSION JOINT
FOUNDATION WALL
PAREX BASE COAT WITHREINFORCING MESH EMBEDDED
E.P.S.
E6.01 WOOD FRAMED SILL (NON-RESIDENTIAL)
E7.01 WOOD FRAMED FLOOR LINE (NON-RESIDENTIAL)
WOOD FRAMING
PLYWOOD SHEATHING
ADHESIVELY ATTACHED EPS
PAREX BASE COATWITH MESH EMBEDDED
PAREX FINISH
CLOSED CELL POLYETHYLENEBACKER AND ELASTOMERICSEALANT
3/4” (19 mm) MIN.
PAREX TRACK 363
SOLE PLATE
SUBFLOOR
RIM JOIST
PB EIF System Details
SUBSTRATE
PAREX ADHESIVE
EXPANDED POLYSTYRENE (EPS)
RECOMMENDED PAREX HIGH IMPACTMESH 358.14 EMBEDDED IN PAREXBASE COAT
PAREX MESH EMBEDDEDIN PAREX BASE COAT
PAREX FINISH
PAREX TRACK 363 OR BACKWRAPAS IN T2.01
FOUNDATION
PAVEMENT
T1.01 TERMINATION ABOVE PAVEMENT
2” (5cm) MINIMUM
SUBSTRATE
PAREX ADHESIVE
EXPANDED POLYSTYRENE (EPS)
RECOMMENDED PAREX HIGH IMPACT MESH358.14 EMBEDDED IN PAREX BASE COAT
PAREX MESH EMBEDDEDIN BASE COAT
PAREX FINISH
PAREX SHORT DETAIL MESH 356 BACKWRAPPEDAND EMBEDDED IN BASE COAT OR USE TRACK
AS IN T1.01
T2.01 TERMINATION ABOVE GRADE
6” (15 cm) MIN.TO GRADE
FOUNDATION
FOUNDATION
SUBSTRATE
PAREX ADHESIVE
EXPANDED POLYSTYRENE (EPS)
RECOMMENDED PAREX HIGH IMPACTMESH 358.14 EMBEDDED IN PAREX
BASE COAT
PAREX MESH EMBEDDEDIN BASE COAT
PAREX FINISH
T3.01 BASE COAT BELOW GRADE
6” (15cm) MIN. TO GRADE
NOTE: APPLICATIONS DIRECTLYAPPLIED TO CONCRETE SHALLBE BASE COAT 121
T6.01 TERMINATION AT BALCONY DECK
SUBSTRATE
PAREX ADHESIVEEPS
PAREX BASE COAT WITHREINFORCING MESH
EMBEDDED
PAREX FINISH
PAREX VENTEDTRACK 363
ELASTOMERIC SEALANT
PITCH FOR POSITIVE DRAINAGE
BALCONY DECK
COMPRESSEDFOAM TAPE
PB EIF System Details
JAMB
W1.01 BACKWRAPPED JAMB
CLOSED CELL POLYETHYLENE BACKER ANDELASTOMERIC SEALANT, WITH SEALANTMANUFACTURER’S RECOMMENDED PRIMER
PAREX SHORT DETAIL MESH 356 BACKWRAPPEDAND EMBEDDED IN BASE COAT
PAREX FINISHPAREX BASE COAT WITHREINFORCING MESH EMBEDDED
EPS
SUBSTRATE
PAREX ADHESIVE
W2.01 COMPRESSED FOAM TAPE TERMINATION AT FLUSH / PROJECTING JAMB
JAMB
SUBSTRATE
PAREX ADHESIVE
EPS
COMPRESSED FOAM TAPE
PAREX BASE COAT WITHREINFORCING MESH EMBEDDED
PAREX FINISH
W3.01 INSULATED JAMB RETURN
JAMB
DOUBLE WRAPPED MESH EMBEDDEDIN BASE COAT
PAREX FINISH
PAREX BASE COAT WITHREINFORCING MESH EMBEDDED
EPS
PAREX ADHESIVE
SUBSTRATE
CLOSED CELL POLYETHYLENE BACKERAND ELASTOMERIC SEALANT WITH SEALANTMANUFACTURER’S RECOMMENDED PRIMER
W4.01 UNINSULATED JAMB RETURN
JAMB
CLOSED CELL POLYETHYLENE BACKERAND ELASTOMERIC SEALANT WITH SEALANTMANUFACTURER’S RECOMMENDED PRIMER
DOUBLE WRAPPED MESH EMBEDDEDIN BASE COAT
PAREX FINISH
MASONRY SUBSTRATE
PAREX ADHESIVE PAREX BASE COAT WITHREINFORCING MESH EMBEDDED
EPS
W5.01 HEAD WITH VENTED TRACK 363
SUBSTRATE
PAREX ADHESIVE
EPS
PAREX BASE COAT WITHREINFORCING MESH EMBEDDED
PAREX FINISH
PAREX VENTED TRACK 363
CLOSED CELL POLYETHYLENEBACKER AND ELASTOMERIC SEALANT
HEAD
W6.01 INSULATED HEAD RETURN
SUBSTRATE
PAREX ADHESIVE
EPS
PAREX BASE COAT WITHREINFORCING MESH EMBEDDED
PAREX FINISH
DOUBLE WRAPPED MESHEMBEDDED IN BASE COAT
DRIP GROOVE
HEAD
CLOSED CELL POLYETHYLENE BACKERAND ELASTOMERIC SEALANT WITH SEALANTMANUFACTURER’S RECOMMENDED PRIMER
3/4” (19 mm) MIN.
PB EIF System Details
W7.02 UNINSULATED HEAD RETURN
MASONRY SUBSTRATE
PAREX ADHESIVE
EPS
PAREX BASE COAT WITHREINFORCING MESH EMBEDDED
PAREX FINISH
DRIP EDGE
PAREX SHORT DETAIL MESHBACKWRAPPED AND EMBEDDEDIN BASE COAT
3/4” (19 mm) MAX.
PAREX BASE COAT& PAREX FINISH
CLOSED CELL POLYETHYLENE BACKERAND ELASTOMERIC SEALANT WITH SEALANTMANUFACTURER’S RECOMMENDED PRIMER
HEAD
W8.03 ROUGH SILL EDGE WRAPPED PRIOR TO FLASHING
SILL
JAMB RETURN BEYOND
MESH EMBEDDED IN BASE COATCONTINUOUS THROUGH SILL / JAMBRETURN INTERFACE
FLASHING
1” (25 mm) MIN.
ELASTOMERIC SEALANT
PAREX BASE COAT WITH PAREXREINFORCING MESH EMBEDDEDLAPPING OVER FRAMING
PAREX ADHESIVE
EPS
PAREX BASE COAT WITHREINFORCING MESH EMBEDDED
PAREX FINISH
W8.04 BACKWRAPPED TERMINATION AT SILL
SILL
JAMB RETURN BEYOND
MESH EMBEDDED IN BASE COATCONTINUOUS THROUGH SILL /JAMBRETURN INTERFACE
FLASHING
1” (25 mm) MIN.
PAREX SHORT DETAIL MESH 356BACKWRAPPED AND EMBEDDEDIN BASE COAT
ELASTOMERIC SEALANT
PAREX ADHESIVE
EPS
PAREX BASE COAT WITHREINFORCING MESH EMBEDDED
PAREX FINISH
R1.03 PARAPET
1 1/2” (38 mm)MINIMUM
PAREX SHORT DETAIL MESH 356BACKWRAPPED & EMBEDDED inBASE COAT
SUBSTRATE
ELASTOMERIC SEALANT
PAREX ADHESIVE
EPS
PAREX BASE COAT WITHREINFORCING MESH EMBEDDED
PAREX FINISH
METAL COPING / FLASHING
R1.04 PARAPET COATED PRIOR TO FLASHING
1 1/2” (38 mm) MINIMUM
METAL COPING / FLASHING
PAREX MESH REINFORCED BASECOAT WRAPPING EPS ANDOVERLAPPING SUBSTRATE
SUBSTRATE
ELASTOMERIC SEALANT
PAREX ADHESIVE
EPSPAREX BASE COAT WITHREINFORCING MESH EMBEDDED
PAREX FINISH
PB EIF System Details
R2.01 HIGH WALL AT LOW ROOF
SUBSTRATE
PAREX ADHESIVE
EPS
PAREX BASE COATWITH REINFORCING MESH
EMBEDDED4” (10 cm) MIN.OVERLAP ONTO
FLASHING PAREX FINISH
PAREX TRACK 363OR BACKWRAP WITHSHORT DETAIL MESH 356
8” (20 cm)MINIMUM
FRAMING
BASE FLASHING
R3.01 GRAVEL STOP
GRAVEL STOP
BACKWRAPPED SHORT DETAIL MESHEMBEDDED IN BASE COAT
1 1/2” (38 mm)MIN.
ELASTOMERIC SEALANT
SUBSTRATE
PAREX ADHESIVE
EPS
PAREX BASE COAT WITHREINFORCING MESHEMBEDDED
PAREX FINISH
R4.01 INSULATED SOFFIT
SUBSTRATE
PAREX ADHESIVE
EPS
PAREX BASE COAT WITHREINFORCING MESH EMBEDDED
PAREX FINISH
3/4” (19 mm) MIN.EPS THICKNESSSEE DETAIL A1.02FOR GROOVE
OUTSIDE CORNERSEE DETAIL G5.01
INSDIE CORNERSEE DETAIL G4.01
3” (7.6 cm) MAX.
NOTE: FOR UNCONDITIONEDAIR SPACE, PROVIDE VENTILATION AS REQUIRED
R5.03 TERMINATION AT SOFFIT
CLOSED CELL BACKER ANDELASTOMERIC SEALANT, WITHSEALANT MANUFACTURER’SRECOMMENDED PRIMER
PAREX SHORT DETAIL MESH356 BACKWRAPPED AND EMBEDDED IN BASE COAT
PAREX TRACK 363
SUBSTRATE
3/4” (19 mm) MAX.
BACKWRAPPED PAREX SHORTDETAIL MESH 356 EMBEDDED INBASE COAT
PAREX DIRECT SOFFIT APPLICATION
NOTE: FOR UNCONDITIONEDAIR SPACE, PROVIDEVENTILATION AS REQUIRED
COMPRESSED FOAMTAPE
PAREX ADHESIVE
EPSPAREX BASE COAT WITH
REINFORCING MESH EMBEDDED
PAREX FINISH
ALTERNATES
PB EIF System Details
R6.02 INTERSECTION OF ROOF CORNICE AT STANDARD SYSTEM WALL
5” (13 cm)MIN.
5” (13 cm)MIN.
8” (20 cm)
110°
WATER TIGHTSEAMS
KICK-OUT FLASHINGCONSTRUCTION
KICK-OUT SHOULD EXTEND 3” (7.6 cm) MINBEYOND THE FACE OF THE SYSTEM
BACKWRAP AROUND KICK-OUTWITH MESH REINFORCED BASECOAT. SEAL WITH CLOSED CELLBACK ROD & ELASTOMERIC SEALANT.
FASCIA
PAREX STANDARDSYSTEM
CONTINUOUS STEP FLASHING SEE DETAIL R6.02B FOR MORE INFO.
UNDERLAYMENT
METAL DRIP EDGE
SEE DETAILS R5.03FOR RELATED INFO.
ROOF SHINGLES
SEE RELATED DETAIL R6.02BFOR TERMINATION OF STANDARDSYSTEM ABOVE ROOF
SUBSTRATE
PAREX ADHESIVE
EXPANDED POLYSTYRENE
PAREX MESH REINFORCEDBASE COAT
PAREX FINISH
PAREX TRACK 363
METAL STEP FLASHING
ROOF SHINGLE
UNDERLAYMENT
2” MIN.
4” MIN.
R6.02B INTERSECTION OF ROOF CORNICE AT STANDARD SYSTEM WALL
PAREX BASE COAT WITHREINFORCING MESH EMBEDDED.NOTE 2 1/2” (6.3 cm) MIN. OVER-LAP AT DETAIL MESH.
PAREX SHORT DETAIL MESH 356EMBEDDED IN BASE COAT
PITCH FORPOSITIVEDRAINAGE
PAREX FINISH
EPS
PAREX ADHESIVE
SUBSTRATE
A1.02 AESTHETIC GROOVE / REVEAL
PAREX FINISH
PAREX BASE COAT WITH REINFORCING MESH EMBEDDED NOTE: 2 1/2” (6.3 cm) MIN. OVERLAP AT DETAIL MESH.
PAREX DETAIL MESH EMBEDDED IN BASE COAT
PAREX ADHESIVE
EPS FEATURE
EPS
PAREX ADHESIVE
SUBSTRATE
A2.01 SMALL AESTHETIC BAND / PROJECTION
PB EIF System Details
P3.01 REMOVABLE APPLIANCE
SUBSTRATE
PAREX ADHESIVE
EPS
PAREX TRACK
REMOVABLE APPLIANCE
PAREX BASE COAT WITHREINFORCING MESH EMBEDDED
PAREX FINISH
P1.01 FIXTURE ATTACHMENT
FRAMING
SUBSTRATE
PAREX ADHESIVEEPS
BLOCKING
ELASTOMERIC SEALANT
CORROSION RESISTANT FASTENER
CORROSION RESISTANT WASHER
P.V.C. PIPE SLEEVE FILLED WITHELASTOMERIC SEALANT
FIXTURE
PAREX BASE COAT WITHREINFORCING MESH EMBEDDED
PAREX FINISH
P2.02 SCUPPER
SUBSTRATE
PAREX ADHESIVEEPS
PAREX BASE COAT WITHREINFORCING MESH EMBEDDED
BACKWRAPPED PAREX SHORTDETAIL MESH EMBEDDEDIN BASE COAT
PAREX FINISH
4” (10 cm) MIN.
SCUPPER
CLOSED CELL BACKER &ELASTOMERIC SEALANT, WITH
SEALANT MANUFACTURER’SRECOMMENDED PRIMER
PB EIF System Details
CSI SECTION 07 24 00
Corporate OfficeParexLaHabra4125 E. La Palma Avenue, Suite 250Anaheim, CA 92807(714) 778-2266
Sales OfficeParex1870 Stone Mountain-Lithonia RoadRedan, GA 30074(800) 537-2739
PlantsRiverside, CAFrench Camp, CAColorado Springs, COAlbuquerque, NMSan Antonio, TXWilkes Barre, PARedan, GA
www.parex.com© ParexLahabra July 2007 • PPBESD
Parex Assistance Request
Thank you for your interest. In an effort to keep you informed, we would like you to fill out this brief registration form.
Name:
Company:
Address:
City:
State: Zip: Country:
Phone:
e-mail:
Occupation:
Are you presently working on a project? Yes No
Type:
Size in Sq. Ft.: