Page 1: PCM600 v2.5 Product Guide

Protection and Control IED ManagerPCM600Product Guide

Page 2: PCM600 v2.5 Product Guide

Contents

1. Description.....................................................................3

2. Project explorer..............................................................4

3. Parameter setting...........................................................4

4. Graphical application configuration.................................4

5. Signal matrix...................................................................5

6. Graphical display editor..................................................5

7. Hardware configuration..................................................6

8. IED configuration comparison.........................................6

9. Signal monitoring............................................................6

10. Event viewer..................................................................6

11. Disturbance handling.....................................................6

12. Communication management.......................................6

13. IEC 61850 configuration................................................6

14. Connectivity packages..................................................7

15. User management.........................................................7

16. Integrated help menus...................................................7

17. Data transfer.................................................................7

18. System requirements....................................................8

19. Ordering data................................................................8

20. Document revision history.............................................9

Disclaimer

The information in this document is subject to change without notice and should not be construed as a commitment by ABB. ABB assumes no responsibility for any

errors that may appear in this document.

© Copyright 2013 ABB.

All rights reserved.

Trademarks

ABB is a registered trademark of the ABB Group. All other brand or product names mentioned in this document may be trademarks or registered trademarks of their

respective holders.

Protection and Control IED Manager 1MRS756448 HPCM600 Product version: 2.5

2 ABB

Page 3: PCM600 v2.5 Product Guide

1. DescriptionThe Protection and Control IED Manager PCM600tool provides versatile functionalities for the entire

life-cycle of all Relion® protection and control IEDapplications, at all voltage levels. This easy-to-handle tool helps the user to manage yourprotection and control equipment all the way fromapplication and communication configuration todisturbance handling, including automaticdisturbance reporting.

Designed to communicate, PCM600 interactswith IEDs over the fast and reliable TCP/IP viacorporate LAN or WAN, or alternatively directlythrough the communication port at the front of

the IED. PCM600 tool is able to read and write allconfiguration and setting data of an IED with asingle command.

The user interface, workflow and the IEC 61850-based data model in PCM600 are designed

according to the same philosophy as the Relion®

protection and control IEDs, ensuring smooth andseamless integration between the tool and theIEDs.

PCM600 also secures the projects and datacreated with earlier versions of the PCM600 tool,which enables full backwards compatibility.

GUID-BC9474F6-E579-4326-99E8-433B8A3FEB99 V2 EN

Figure 1. PCM600 connected locally or remotely to IEDs

Protection and Control IED Manager 1MRS756448 HPCM600 Product version: 2.5 Issued: 2013-01-10

Revision: H

ABB 3

Page 4: PCM600 v2.5 Product Guide

2. Project explorerThe project explorer can be used to navigate tothe used IEDs within a project / substation andfurthermore within an IED to navigate to thedifferent functionality of an IED. The user is ableto create a plant structure with a substation,voltage levels, bays and IEDs.

New IEDs can also be created by use of IEDtemplates. This enables the reuse of existing IEDconfigurations. IEDs, bays, voltage levels or awhole substation can be copied and pasted in theplant structure. Selection of a specific IED in theproject explorer gives access to the IED’s tools.The function of importing and exportingdescriptions of IEC 61850 substationconfigurations, configured devices and devicefunctionality allows information to be shared withother engineering and system integration tools.By using the filtering feature of the projectexplorer the user can filter information of othertools according to the selection made.

3. Parameter settingThe parameter setting of PCM600 enablesviewing and setting IED parameters offline (storedin the tool) and online (stored in both the tool andthe IED). The parameters can be read from theIED to PCM600 or written from PCM600 to theIED while the IED is in service. In addition, theparameters can be exported and imported for testsets in the XRIO format (for example, OmicronTest Universe) or exported in the CSV format tobe easily read and reused.

The parameter setting function can be used intwo different modes. The normal mode allows aquick viewing and changing of the mostcommonly used parameters, whereas theadvanced mode unveils all parameters that canbe set.

PCM600 further offers a filtering function thatallows the viewing of all IED parameters or theparameters related to a specific function block. Inaddition, it can be chosen to only viewparameters that have been changed orparameters with values deviating from the IED’ssetting. Changed parameters with different valuesin the tool and in the IED are clearly indicated.

GUID-C054605B-7CC8-431C-A4F2-07797F7B5518 V1 EN

Figure 2. Parameter setting view

The graphical representation of the distanceprotection function supports in the visualverification of the parameter setting of thedistance protection function.

GUID-F80A10F3-CA4E-4F35-AA32-D01E531CD3DC V1 EN

Figure 3. Graphical representation of the distanceprotection function

4. Graphical application configurationThe graphical application configurationfunctionality offers powerful ways to create, adaptand modify application configurations, which alsocan be made as templates for later re-use.PCM600 also enables presentation of the wholesignal flow from input to output. It also assists theuser during the creation of applicationconfiguration through colour indications of thefunction blocks to ensure that the mandatoryinputs have been correctly connected. Beforewriting the configuration to an IED, the tool offers

Protection and Control IED Manager 1MRS756448 HPCM600 Product version: 2.5

4 ABB

Page 5: PCM600 v2.5 Product Guide

validation of the complete IED configuration whichensures that the configuration does not containerrors.

Additionally, the user can compare theconfiguration in the tool to the one in the IED.Further, the signal status on-line monitoringfunctionality helps to verify the real-timeprocesses in the IED, which is extremely useful fortroubleshooting.

GUID-62510AC1-D402-425C-A00D-FD0B97138922 V2 EN

Figure 4. Application configuration, Online monitoring

GUID-A565A681-95ED-4CEC-B721-DD119BEBE400 V2 EN

Figure 5. Application configuration, visual indicationof the configuration

5. Signal matrixThe graphical signal matrix of PCM600 allowsconnecting efficiently CTs, VTs, binary input andoutput signals to the configuration. The

configuration can also be changed from here. Thetool can also be used for connecting the LEDs onthe IED as well as for connection of the GOOSEsignals between the IEDs.

Once the IEDs have been configured andparameterized, PCM600 enables theconfiguration of the horizontal bay-to-baycommunication for station-wide interlocking andsends the complete IED description to a systemengineering tool.

GUID-ADD28079-AE48-4C38-BA28-138FDEE21977 V2 EN

Figure 6. Signal matrix tool view

6. Graphical display editorThe graphical display editor is used forconfiguring the display of an IED. The graphicaldisplay consists of one or more pages. A displaypage contains the drawing area where the actualdisplay configuration is made. A display isconfigured by dragging predefined graphicalsymbols from a library to the drawing area. Thedirected link tool can be used to drawconnections between symbols. Every symbol typehas a corresponding representation in both theANSI and the IEC symbol palettes. Symbols canbe connected to the application configuration.

The graphical display editor also supports thereuse of display page templates made for otherIEDs.

Protection and Control IED Manager 1MRS756448 HPCM600 Product version: 2.5

ABB 5

Page 6: PCM600 v2.5 Product Guide

GUID-3248B496-F627-44AD-9261-ABB812508CAA V2 EN

Figure 7. Graphical display editor, configuring thedisplay of an IED

7. Hardware configurationThe hardware configuration can be used to get aquick overview of an IED and to add or changehardware modules. It is possible to view the frontand back of the IED including card informationand their slot position. Furthermore it is possibleto compare the hardware configuration used inthe tool to the actual one in the IED.

8. IED configuration comparisonIED comparison is used for comparingconfigurations of two IEDs of the same kind.Comparison can be made offline regardless of theIEDs being in the same PCM600 project or not.Additionally, the configuration of an IED can becompared to a loose PCMI file. When connectedto the IED, it is possible to compare theconfigurations between the IED and the PCM600online. A report of the differences between thetwo different IED configurations is provided as aresult of the comparison.

9. Signal monitoringThe signal monitoring function provides the userwith online information about the measuredvalues and displays the status of binary input andoutput signals of an IED. Furthermore, PCM600facilitates commissioning and testing of physicalconnections via the signal monitoring tool (forcingof signals).

10. Event viewerThe event viewer of PCM600 enables viewing theIED sequence of events information includingtimestamps. The event log facilitates detailed post-fault analyses of faults and disturbances. Eventviewer additionally enables reading the securityevents from the IED.

11. Disturbance handlingPCM600 offers effective handling and monitoringof disturbance records from the IEDs. Thedisturbance files stored in the standardCOMTRADE format allow the user to view thedisturbance record using Wavewin™ software orany commercially available disturbance analyzersupporting the COMTRADE format. If required,the report layout and contents can be adapted touser-specific needs.

By means of the task scheduler of PCM600, therecords can be set to be automatically read fromthe IED. The task scheduler is an independentprocess and does not require PCM600 to beactivated. After receiving the file, PCM600automatically creates a disturbance report, whichcan immediately be forwarded to subscribers by e-mail. Such a notification shortens the time fromdisturbance detection to corrective action.

12. Communication managementThe Communication Management tool is used toconfigure different communication protocols foran IED. DNP3, IEC 60870-5-101/103/104 or

Modbus® are the communication protocols thatcan be engineered. Depending on the usedprotocol, the tool provides different views andcapabilities to support in the selection or mappingof communication signals.

13. IEC 61850 configurationThe IEC 61850 configuration tool of PCM600provides the viewing or engineering of the datasetand dataflow configuration for a vertical orhorizontal IEC 61850 communication.

In the view mode, the tool supports the viewing ofthe IEC 61850 configuration, whereas in theengineering mode it is possible to configure IEC61850 datasets and dataflow for the horizontaland vertical communication.

Protection and Control IED Manager 1MRS756448 HPCM600 Product version: 2.5

6 ABB

Page 7: PCM600 v2.5 Product Guide

Table 1. Recommendations for using the IEC 61850 configuration tools

IEC 61850 tools in a Substation automation system (SAS)

No external tool IET600 or 3rd party system tool

ABB Relion IEDs Engineering mode 1) View mode 2)

ABB and 3rd party IEDs View mode 2) View mode 2)

1) Engineering mode of IEC 61850 configuration tool of PCM600 is recommended for simple applications. Advanced applications require an IEC 61850system tool like IET600 and view mode.

2) View mode of IEC 61850 configuration tool of PCM600 for the transparancy of IEC 61850 configuration made by an external IEC 61850 system toollike IET600.

14. Connectivity packagesPCM600 incorporates ABB’s connectivitypackage concept, which simplifies protectionengineering and reduces the risk of errors. Theconnectivity packages can be downloaded andinstalled using the PCM600 Update Manager tool.Furthermore, the IED connectivity packages forthe 670 and 650 series are also available on aseparate IED Connectivity Package DVD that isdelivered with the IEDs, whereas the IEDconnectivity packages for the 630, 620, 615, 611and 610 series, RIO600, REX521, RE_54_,SPACOM and REF 542plus can be downloadedfrom the www.abb.com/substationautomationportal.

15. User managementPCM600 tool supports access management bothfor the tool and the IEDs. The user accounts inPCM600 can be linked to Windows user accountsor be defined as separate user accounts forPCM600. The user management feature allowsthe administrator to create user groups withdifferent access rights and profiles.

The access management for the IEDs can beenabled or disabled with the IED user

management tool in PCM600. This tool is alsoused for setting and changing passwords for theIED’s different user levels.

16. Integrated help menusAll the necessary instructions for using the toolare integrated in PCM600. Context sensitive helpmenus and tool tips provide the user withinformation about the selected tools. The IEDdocumentation and guides available from theconnectivity package can be directly accessedfrom the help menus.

17. Data transferPCM600 offers improved data transfer betweenthe IEDs and the IED management tool. The IEDscan be accessed remotely using the TCP/IPprotocol via a local area network (LAN) andstandard Ethernet cables, a secured wide areanetwork (WAN), a secured wireless network(WLAN) or, locally, using the IEDs’ frontcommunication port.

Protection and Control IED Manager 1MRS756448 HPCM600 Product version: 2.5

ABB 7

Page 8: PCM600 v2.5 Product Guide

18. System requirements

Table 2. Hardware requirements

Hardware Minimum Recommended

CPU 1.0 GHz 2.2 GHz

RAM 1 GB 3 GB

Free hard disk space 2 GB 4 GB

Monitor 1024 x 768 1280 x 1024

Ethernet port required required

Table 3. Supported operating systems

Operating system Version

Microsoft Windows XP Professional 32-bit SP3 or later

Microsoft Windows Server 2003 32-bit SP2

Microsoft Windows Vista Business 32-bit SP2

Microsoft Windows 7 Professional 32-bit SP1

Microsoft Windows 7 Professional 64-bit SP1

Table 4. Communication

Protocols

TCP/IP via LAN or WLAN

Serial Port (RS-232) or USB/RS-232 converter if SPA-based communication is used

Opto/electrical (RS-232) cable for front communication if SPA-based communication is used

19. Ordering dataTo order the protection and control IED managerPCM600, use the ordering data in the orderingcode table.

Table 5. Ordering code

Product name Order number

PCM600 2.5 PCM600-25

Protection and Control IED Manager 1MRS756448 HPCM600 Product version: 2.5

8 ABB

Page 9: PCM600 v2.5 Product Guide

20. Document revision history

Document revision/date Product version History

A/2007-12-20 2.0 First release

B/2008-05-30 2.0 SP1 Content updated

C/2009-03-03 2.0 SP2 Content updated

D/2009-07-06 2.1 Content updated to correspond to the product version

E/2009-11-23 2.2 Content updated to correspond to the product version

F/2010-05-28 2.3 Content updated to correspond to the product version

G/2011-04-08 2.4 Content updated to correspond to the product version

H/2013-01-10 2.5 Content updated to correspond to the product version

Protection and Control IED Manager 1MRS756448 HPCM600 Product version: 2.5

ABB 9

Page 10: PCM600 v2.5 Product Guide

10

Page 11: PCM600 v2.5 Product Guide
Page 12: PCM600 v2.5 Product Guide

Contact us

ABB OyMedium Voltage Products,Distribution AutomationP.O. Box 699FI-65101 VAASA, FinlandPhone +358 10 22 11Fax +358 10 22 41094

ABB ABSubstation Automation ProductsSE-721 59 Västerås, SwedenPhone +46 (0) 21 32 50 00Fax +46 (0) 21 14 69 18

www.abb.com/substationautomation

1MR

S75

6448

Cop

yrig

ht 2

013

AB

B. A

ll rig

hts

rese

rved

.