performance stat

2
Performance Statistics - Flowch arts for Counters C 00 01114M End RRC Connection Setup YES pmT otNoRrcConnectReqSucc + pmT otNoT ermRrcConnectReqSucc + pmT otNoRrcConnectReqCsSucc + pmT otNoT ermRrcConnectReqCsSucc + Release of already allocated resources RRC CONNECTION SETUP SRNC UE RRC CONNECTION SETUP COMPLETE SRNC UE RADIO LINK RESTORE INDICATION SRNC RBS Increment only once even if repeated RRC Connection Requests RRC CONNECTION REJECT SRNC UE pmT otNoUtranRejRrcConnReq + If timer does not expire: NO YES YES NO Send RRC Connection Setup and start timer RRC CONNECTION RELEASE SRNC UE RRC CONNECTION RELEASE COMPLETE SRNC UE Send RRC connection Release, start timer, receive RRC Connection Release Complete/timer expires Successful  Admission Control? NO YES pmNoRrcCsReqDeniedAdm+ pmNoRrcReqDeniedAdm+ pmNoReqDeniedAdm+ Failed due to TN block? NO YES Step the relevant counter(s): pmNoRrcConnReqBlockTnCs + pmNoRrcConnReqBlockNodeCs + YES  Admission reject due to Unisaal/Sctp congestion? NO NO YES RRC Connection Setup is triggered by RRC Connection Request message YES pmT otNoRrcConnectReq + pmTotNoTermRrcConnectReq + pmT otNoRrcConnectReqCs + pmT otNoT ermRrcConnectReqCs + pmT otNoRrcConnectReqSubTr + RRC CONNECTION REQUEST SRNC UE Increment only once, even if repeated RRC Connection Requests. For pmTotNoRrcConnectReq, step for all Establishment Causes. For pmTotNoRrcConnectReqCs, step for Establishment Cause = Emergency Call or Originating or Terminating Conversational Call. For pmTotNoT ermRrcConnectReq, step for cause = ‘Terminating Conversational Call’, ‘T erminating Streaming Call’, ‘Terminating  Interactive Call’, ‘T erminating Background Call’, T erminating High Priority Signalling’, ‘Terminating Low Priority Signalling’ or ‘T erminating - cause unknown’. For pmTotNoT ermRrcConnectReqCs, step for cause = ‘Terminating Conversational Call’. For pmTotNoRrcConnectReqSubT r, step for couse = ‘Originating Subscribed Traffic Call’. pmNoRejRrcConnMpLoadC +  NO Release of already allocated resources Successful Load Control? Release of already allocated resources pmNoLoadSharingRrcConn + pmNoLoadSharingRrcConnCs + Check with Load Control  Admission reject as a result of load sharing? Radio Link Setup pmNoFailedRrcConnectReqHw + pmNoFailedRrcConnectReqCsHw + or  pmNoRrcReqDeniedAdmDlPwr + or  pmNoRrcReqDeniedAdmDlChnlCode+ or  pmNoRrcReqDeniedAdmDlHw + or  pmNoRrcReqDeniedAdmUlHw + Successful setup?  Admission reject due to other reason?  pmTotNoRrcConnectSetup +  pmTotNoUtranRejRrcConnReq +  pmTotNoRrcReq + NO RRC Connection Setup Complete and NBAP Radio Link Restore Indication are received before timer expires? *) Stepped for Establishement Cause = Originating or T erminating Conversational Call, Emergency, Subscribed, Originating or Terminating Interactive/Background Call. pmT otNoRrcConnectUeCapability + * pmT otNoRrcConnectUeCapability + * Figure 3 RRC Connect ion Set up - C S Sc enar io 10  103/1551- AXD 105 03/ 1 Uen G | 2010-08-24

Upload: mousam-jha

Post on 07-Jul-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

8/18/2019 Performance Stat

http://slidepdf.com/reader/full/performance-stat 1/1

Performance Statistics - Flowcharts for Counters

C 00 01114M

End RRC Connection Setup

YES

pmTotNoRrcConnectReqSucc +pmTotNoTermRrcConnectReqSucc +pmTotNoRrcConnectReqCsSucc +

pmTotNoTermRrcConnectReqCsSucc +

Release of alreadyallocated resources

RRC CONNECTIONSETUP

SRNCUE

RRC CONNECTIONSETUP COMPLETE

SRNCUE

RADIO LINKRESTOREINDICATION

SRNCRBS

Increment only onceeven if repeated RRCConnection Requests

RRC CONNECTIONREJECT

SRNCUEpmTotNoUtranRejRrcConnReq +

If timer does not expire:

NO

YES

YES

NO

Send RRC ConnectionSetup and start timer 

RRC CONNECTIONRELEASE

SRNCUE

RRC CONNECTIONRELEASE COMPLETE

SRNCUE

Send RRC connection Release,start timer, receive RRC

Connection ReleaseComplete/timer expires

Successful Admission Control?

NO

YES

pmNoRrcCsReqDeniedAdm+pmNoRrcReqDeniedAdm+

pmNoReqDeniedAdm+

Failed dueto TN block?

NO

YES

Step the relevant counter(s):pmNoRrcConnReqBlockTnCs +

pmNoRrcConnReqBlockNodeCs +

YES

 Admission reject

due to Unisaal/Sctp

congestion?

NO

NO

YES

RRC Connection Setup is triggeredby RRC Connection Request message

YES

pmTotNoRrcConnectReq +pmTotNoTermRrcConnectReq +pmTotNoRrcConnectReqCs +

pmTotNoTermRrcConnectReqCs +pmTotNoRrcConnectReqSubTr +

RRC CONNECTIONREQUEST

SRNCUE

Increment only once, even if repeated RRC Connection Requests.

For pmTotNoRrcConnectReq, step for all Establishment Causes.For pmTotNoRrcConnectReqCs, step for Establishment Cause =Emergency Call or Originating or Terminating Conversational Call.For pmTotNoTermRrcConnectReq, step for cause = ‘TerminatingConversational Call’, ‘Terminating Streaming Call’, ‘Terminating Interactive Call’, ‘Terminating Background Call’, Terminating HighPriority Signalling’, ‘Terminating Low Priority Signalling’ or‘Terminating - cause unknown’.For pmTotNoTermRrcConnectReqCs, step for cause = ‘TerminatingConversational Call’.For pmTotNoRrcConnectReqSubTr, step for couse = ‘OriginatingSubscribed Traffic Call’.

pmNoRejRrcConnMpLoadC +  NO

Release of already

allocated resources

SuccessfulLoad Control?

Release of alreadyallocated resources

pmNoLoadSharingRrcConn +

pmNoLoadSharingRrcConnCs +

Check with Load Control

 Admission

reject as a result of load sharing?

Radio Link Setup

pmNoFailedRrcConnectReqHw +pmNoFailedRrcConnectReqCsHw +

or  pmNoRrcReqDeniedAdmDlPwr +

or  pmNoRrcReqDeniedAdmDlChnlCode+

or  pmNoRrcReqDeniedAdmDlHw +

or  pmNoRrcReqDeniedAdmUlHw +

Successful setup?

 Admissionreject due to other

reason?

 pmTotNoRrcConnectSetup +

 pmTotNoUtranRejRrcConnReq +

 pmTotNoRrcReq +

NORRC Connection

Setup Complete and NBAP RadioLink Restore Indication are

received before timer expires?

*) Stepped for Establishement Cause = Originating or Terminating Conversational Call, Emergency, Subscribed,

Originating or Terminating Interactive/Background Call.

pmTotNoRrcConnectUeCapability + *

pmTotNoRrcConnectUeCapability + *

Figure 3 RRC Connection Setup - CS Scenario 

10   103/1551-AXD 105 03/1 Uen G | 2010-08-24