pharmaceutical checkweigher - holimex...∗ the minimum belt pitch of the checkweigher is 150 mm...

12
Checkweigher Pharmaceutical April 2014

Upload: others

Post on 18-Feb-2021

6 views

Category:

Documents


0 download

TRANSCRIPT

  • CheckweigherPharmaceutical

    April 2014

  • 2

    Bottles/Cans

    Standing pouches

    Sachets/Sticks

    Capsules

    6 Lane Checkweigher

    Aerosol Inhaler

    Checkweigher

    Small Bottle

    Checkweigher

    2 Lane Checkweigher

    Case Filling Quality Blister Pack Insert Carton

    Filling control and weight check Missing insert check (magnetic ink)

    Missing pack check Missing carton check

    X-ray

    Inspection

    System

    Case CheckweigherSSV-h Series

    Checkweigher

    Capsule

    Checkweigher Metal Detector

    M Series

    SSV-h Series

    Checkweigher

    Seal/Missing tablet check

    Overall quality management and control system

    Missing blister pack check

    Pharmaceutical Checkweigher

    L i n e u p

    L i n e u p O v e r v i e w

    Quicca is a quality management software

    that helps you realize real-time line

    monitoring and analysis for complete line

    optimization. Product traceability and

    video monitoring options further enhance

    your quality control.

    Refer to the Quicca brochure for details.

    Multi-Lane Checkweigher

    ●Capsules

     Capsule Checkweigher

    ●Sachets/Sticks

     Multi-Lane Checkweigher

    ●Standing pouches

     2 Lane Pouch Checkweigher

    ●Bottles/Cans

     Small Bottle Checkweigher

     Aerosol Inhaler Checkweigher

    ●Bags/Cartons/Cases

     Versatile Checkweighers

    ●Other

     Built-In Multi-Lane Weighing System

     

    4

    5

    6

    7

    8

    9

    10

    I n d e x

    Aerosol Inhaler Checkweigher

    Capsule Checkweigher Small Bottle Checkweigher

    Capsules can be individually checkweighed into three classifications

    (overweight, proper weight, or lightweight) with a maximum speed of

    2000 capsules/min. The automatic cleaning of the weigh table and

    periodic zero-setting maintain high accuracy.

    A space-saving checkweigher for lines where multiple lanes of

    products are inspected with just one unit, such as divided filling

    packaging or tube filling lines. The checkweigher allows

    centralized control of production records for multiple lanes with

    just one indicator.

    The weighing systems have stable transfer and high accuracy

    measurement for slim, small-diameter bottles including nasal

    drops, eye lotions, and cosmetic products that are difficult to

    transfer in an upright position.

    A star wheel feeds aerosol cans to the weigh table at a constant

    speed and with a uniform spacing, achieving high speed weighing

    with a maximum accuracy of ± 10 M.

    2

  • 3

    Bottles/Cans

    Standing pouches

    Sachets/Sticks

    Capsules

    6 Lane Checkweigher

    Aerosol Inhaler

    Checkweigher

    Small Bottle

    Checkweigher

    2 Lane Checkweigher

    Case Filling Quality Blister Pack Insert Carton

    Filling control and weight check Missing insert check (magnetic ink)

    Missing pack check Missing carton check

    X-ray

    Inspection

    System

    Case CheckweigherSSV-h Series

    Checkweigher

    Capsule

    Checkweigher Metal Detector

    M Series

    SSV-h Series

    Checkweigher

    Seal/Missing tablet check

    Overall quality management and control system

    Missing blister pack check

    Pharmaceutical Checkweigher

    L i n e u p

    L i n e u p O v e r v i e w

    Quicca is a quality management software

    that helps you realize real-time line

    monitoring and analysis for complete line

    optimization. Product traceability and

    video monitoring options further enhance

    your quality control.

    Refer to the Quicca brochure for details.

    Multi-Lane Checkweigher

    ●Capsules

     Capsule Checkweigher

    ●Sachets/Sticks

     Multi-Lane Checkweigher

    ●Standing pouches

     2 Lane Pouch Checkweigher

    ●Bottles/Cans

     Small Bottle Checkweigher

     Aerosol Inhaler Checkweigher

    ●Bags/Cartons/Cases

     Versatile Checkweighers

    ●Other

     Built-In Multi-Lane Weighing System

     

    4

    5

    6

    7

    8

    9

    10

    I n d e x

    Aerosol Inhaler Checkweigher

    Capsule Checkweigher Small Bottle Checkweigher

    Capsules can be individually checkweighed into three classifications

    (overweight, proper weight, or lightweight) with a maximum speed of

    2000 capsules/min. The automatic cleaning of the weigh table and

    periodic zero-setting maintain high accuracy.

    A space-saving checkweigher for lines where multiple lanes of

    products are inspected with just one unit, such as divided filling

    packaging or tube filling lines. The checkweigher allows

    centralized control of production records for multiple lanes with

    just one indicator.

    The weighing systems have stable transfer and high accuracy

    measurement for slim, small-diameter bottles including nasal

    drops, eye lotions, and cosmetic products that are difficult to

    transfer in an upright position.

    A star wheel feeds aerosol cans to the weigh table at a constant

    speed and with a uniform spacing, achieving high speed weighing

    with a maximum accuracy of ± 10 M.

    CapsulesSachets/Sticks

    Standing pouchesBottles/Cans

    Bags/Cartons/CasesOther

  • 4

    Pharmaceutical Checkweigher

    Capsule Checkweigher

    KW9001AP

    KW9002AP

    CapsulesStanding pouches

    Bottles/CansBags/Cartons/Cases

    Other Sachets/Sticks

    SpecificationsModel KW9001AP KW9002APWeighing range 20 to 1000 MScale interval 0.5 MThroughput 1 Maximum 120,000 capsules/hour Maximum 60,000 capsules/hourAccuracy (3σ) 1 Maximum ± 2 MDisplay ELOperation method Flat panel keyIndication range 1100 MClassification Maximum 20Preset memory 3Product size Capsule No. 00 to 5Power requirements 100 Vac ±10%, single phase, 50/60 Hz, 600 VA 100 Vac ±10%, single phase, 50/60 Hz, 550 VAAir requirements 0.3 to 0.9 MPa, 30R/min [A.N.R.] 0.3 to 0.9 MPa, 15R/min [A.N.R.]Mass 600 O 500 OEnvironmental conditions 15° to 25°C (variation not to exceed 1°C/hour), relative humidity 30% to 70%, non-condensingProtection class IP30Exterior Stainless steel (SUS304)

    1: Accuracy and throughput depends on the application and the rejector.Note: The noise level of this system does not exceed 70 dB(A).

    KW9001AP KW9002AP

    ∗Tower Light is an option.

    External Dimensions

    Control panel

    Rejector unit

    Air inlet

    8 dia. quick coupling

    Discharge direction:

    Right (optional)NG capsule chute

    Hopper (100R)

    38

    5

    67

    0

    15

    024

    6

    46

    53

    50°

    20°

    10

    20

    18

    75

    98.6

    667

    Pass capsule chute width

    141.5141.5

    112 109

    735 29294848

    793950

    R375

    5050100

    90 dia.90 dia.

    854

    Leg spacing

    Units: mm

    KW9001AP

    Control panel

    Rejector unit

    Air inlet8 dia. quick coupling

    Discharge direction:Right (optional)NG capsule chute

    Hopper (45R)

    385

    670

    15024

    653

    50°

    20°

    1020

    1875

    98.6

    540.5 268 141.5

    112109735 2929

    4848

    793950 5050 100

    90 dia.90 dia.

    854Leg spacing

    Units: mm

    KW9002AP

    Weighing range: 20 to 1000 MAccuracy (3σ): max. ± 2 MThroughput: max. 120,000 capsules/hour

    Weighing range: 20 to 1000 MAccuracy (3σ): max. ± 2 MThroughput: max. 60,000 capsules/hour

    (Option)(Option)

  • 5

    Pharmaceutical Checkweigher

    Multi-Lane Sachet & Stick Checkweigher (6 lanes)

    KW6023F□6B*

    ∗ 3, 4, and 5 lanes available.∗ Weighing range, accuracy, and throughput other than above available.

    Model KW6023FF6BKW6023FP6BWeighing range 0.5 to 60NScale interval 0.005NThroughput 1 Maximum 150 products/min × 6-laneAccuracy (3σ) 1 Maximum ± 0.015NDisplay 10.4-inch color TFT LCDOperation method Touch panelIndication range 60.45NPreset memory Maximum 100Classification 2

    Product size 2Width 20 to 40 mmLength 46 to 230 mmHeight 5 to 60 mm

    Belt speed 15 to 60 m/minPower requirements 100 to 120 Vac +10% –15% or 200 to 240 Vac +10% –15%, single phase, 50/60 Hz, 600 VA, rush current 62 A (typ.) (20 ms or less)Rejector 3 IntegratedAir requirements 4 0.5 to 0.9 MPa, 0.3R/min [ A.N.R.] (per lane)Mass Weighing unit: 130 O Indicator: 120 O Environmental conditions 0° to 40°C (variation not to exceed 5°C/h to maintain accuracy), relative humidity 30% to 85%, non-condensingProtection class IP30Exterior KW6023FF6B: Painted KW6023FP6B: Stainless steel (SUS304) (excluding some parts)

    1: Accuracy and throughput depends on the application and the rejector.2: The size of the application varies accoding to the rejector. Consult us when the product is transparent or semi-transparent.3: System with no rejector or with rejector having its own feet are available. 4: Maximum air pressure per rejection movement.

    Specifications

    1: The length is the same if the rejector has its own feet.2: The length of pass heights can be customized for your requirements. The minimum is 400 ± 20 mm.3: The standard length of the cable between the indicator and the weighing unit is 5 m; 10 m is available as an option.

    KW6023FF6B(6 lanes)

    External Dimensions

    740

    210

    240

    350

    800

    680

    400

    140

    140

    380

    1490

    405

    195

    1600

    9018

    85

    84

    80

    (650

    )(5

    90)

    (285)

    40 Belt

    wid

    th

    Printer(optional)

    Tower light(optional)

    730690

    650

    R655

    72620

    950610 3403

    202

    770

    Indicator

    Indicator

    Measuring unit

    Flow direction

    1

    23

    M20M20

    60 dia. 60 dia.

    270Weighing unit46 dia.

    roller

    18 dia.roller

    850

    to 1

    000

    700

    to 8

    50Li

    ne h

    eigh

    ts

    Maint

    enan

    cesp

    ace

    Maintenancespace

    Units: mm

    KW6023FF6BKW6023FP6B

    Weighing range: 0.5 to 60NAccuracy (3σ): max. ± 0.015NThroughput: max. 150 products/min x 6 lanes

    Sachets/SticksCapsules

    Standing pouchesBottles/Cans

    Bags/Cartons/CasesOther

  • 6

    Pharmaceutical Checkweigher

    Standing pouchesCapsules

    Bottles/CansBags/Cartons/Cases

    Other Sachets/Sticks

    2 Lane Pouch Checkweigher

    KW6205E□2C*

    Model KW6205EF2CKW6205EP2CWeighing range 2 to 600NScale interval 0.02N/600N, 0.01N/300NThroughput 1 Maximum 400 products/min × 2-laneAccuracy (3σ) 1 Maximum ± 0.02NDisplay 10.4-inch color TFT LCDOperation method Touch panelIndication range 600.9NPreset memory Maximum 100Classification 2 or 3

    Product size 2Width 20 to 160 mmLength 46 to 230 mmHeight 5 to 180 mm

    Belt speed 15 to 120 m/minPower requirements 100 to 120 Vac +10% –15% or 200 to 240 Vac +10% –15%, single phase, 50/60 Hz, 500 VA, rush current 62 A (typ.) (20 ms or less)Mass 75 OEnvironmental conditions 0° to 40°C (variation not to exceed 5°C/h to maintain accuracy), relative humidity 30% to 85%, non-condensingProtection class IP30Exterior KW6205EF2C: Painted KW6205EP2C: Stainless steel (SUS304) (excluding some parts)

    1: Accuracy and throughput depends on the application and the rejector.2: The size of the application varies accoding to the rejector. Consult us when the product is transparent or semi-transparent.

    Specifications

    KW6205EP2C(2 lanes)

    ∗ Weighing range, accuracy, and throughput other than above available.

    External Dimensions

    880

    250

    455

    175

    900

    395

    47

    (300

    ) Maintenance space

    160

    Belt w

    idth

    160

    Belt w

    idth

    Dropout rejector(connection example)

    R300

    30 65130

    2755545

    300

    270

    Flow direction

    M2060 dia.

    410Leg spacing

    190Leg spacing

    25 dia.roller

    18 dia.roller

    18 dia.roller

    1370

    to 1

    470

    700

    to 8

    00Li

    ne h

    eigh

    ts

    Units: mm

    KW6205EF2CKW6205EP2C

    Weighing range: 2 to 600NAccuracy (3σ): max. ± 0.02NThroughput: max. 400 products/min x 2 lanes

    ∗ The belt pitch in this drawing is the minimum pitch when the checkweigher is connected to a dropout rejector.

    ∗ The minimum belt pitch of the checkweigher is 150 mm when the belt width is 100 mm. The value depends on the type of a rejector to be connected. Dropout rejector 185 mm or longer Flipper rejector 150 mm to 220 mm Air jet rejector 300 mm or longer

  • 7

    Pharmaceutical CheckweigherBottles/Cans

    CapsulesStanding pouches

    Bags/Cartons/CasesOther

    Sachets/Sticks

    Small Bottle Checkweigher

    KWS9223 type

    KWS9223BPHB

    Model KWS9223BPHB KWS9223BPHCWeighing range 1 1.2 to 600NScale interval 0.01NThroughput 2 Maximum 200 products/minAccuracy (3σ) 2 Maximum ± 0.02NDisplay 8.5-inch wide color TFT LCDOperation method Touch panel (Start, Stop, and Home are direct push buttons)Indication range 600.9NPreset memory Maximum 200Classification 2 or 3

    Product size 3Width 20 to 40 mmLength 20 to 40 mmHeight 50 to 150 mm

    Belt speed 15 to 60 m/minPower requirements 100 to 120 Vac +10% –15% or 200 to 240 Vac +10% –15%, single phase, 50/60 Hz, rush current 40 A (typ.) (40 ms or less)Power consumption 700 VA 550 VAAir requirements 0.5 to 0.9 MPa, 16R/min [A.N.R.] for air jet rejector Air supply not required (Air jet rejector not mounted)Mass 135 O 90 OEnvironmental conditions 0° to 40°C (variation not to exceed 5°C/h to maintain accuracy), relative humidity 30% to 85%, non-condensingProtection class IP30Exterior Stainless steel (SUS304)

    1: Maximum weight capacity for KWS9223BPHB air jet rejector is 200N.2: Accuracy and throughput depends on the application and the rejector.3: Varies according to the rejector. Consult us when the product is transparent or semi-transparent.Note: The noise level of this system does not exceed 70 dB(A).Note: Optional compliance with FCC Part 15 available.

    Specifications

    External Dimensions

    35

    54

    20

    94

    0

    16

    5

    Le

    g s

    pa

    cin

    g

    60 dia.M20

    270 Windshield

    Weighing unit

    Flowdirection

    Adjustment steering wheel

    Indicator

    Lin

    e h

    eig

    hts

    Air jet rejector

    70

    0 t

    o 8

    50

    18 dia. roller

    40

    Air inlet

    10 mm (outer dia.) quick coupling

    Be

    lt w

    idth

    Printer (optional)

    9 273

    271171

    151

    965

    1407

    NG–BOX

    φ4

    Leg spacing

    43

    03

    75

    69

    0

    Units: mm

    KWS9223BPHB

    Flowdirection

    151

    9 273

    171171 370

    712

    Lin

    e h

    eig

    hts

    Indicator

    Adjusting handle

    270

    70

    0 t

    o 8

    50

    40

    Be

    lt w

    idth

    Printer (optional)

    φ4

    Leg spacing

    43

    03

    75

    35

    54

    20

    94

    0

    16

    5

    Le

    g s

    pa

    cin

    g

    69

    0

    60 dia.M20

    Windshield

    Weighing unit

    Units: mm

    KWS9223BPHC

    Weighing range: 1.2 to 600NAccuracy (3σ): max. ± 0.02NThroughput: max. 200 products/min

    (Option)(Option)

  • 8

    Pharmaceutical Checkweigher

    Bottles/CansCapsules

    Standing pouchesBags/Cartons/Cases

    Other Sachets/Sticks

    Aerosol Inhaler Checkweigher Made To Order

    KW9627AP00

    KW9627AP00

    Model KW9627AP00Weighing range 0.5 to 60NScale interval 0.002NThroughput Maximum 150 products/minAccuracy (3σ) 1 Maximum ± 0.01NDisplay 10.4-inch color TFT LCDOperation method Touch panelIndication range 60.450NPreset memory Maximum 100Classification 3Product size

    Can size 21.5 / 22.0 / 23.5 / 25.0 mm diameter 2Height 40 to 80 mm

    Belt speed 14 m/minPower requirements 3 100 to 115 Vac +10% –15%, single phase, 50/60 Hz, 400 VAAir requirements 0.4 MPa, 20R/min [A.N.R.] (Use dry air.)Mass 150 OEnvironmental conditions 0° to 40°C (variation not to exceed 5°C/h to maintain accuracy), relative humidity 30% to 85%, non-condensingProtection class IP30Exterior Stainless steel (SUS304) (excluding some parts)

    1: The accuracy depends on the application.2: Fixed by size, and cannot be shared. Contact our sales representatives for other sizes.3: 200 to 240 Vac is also available as an option.Note: The noise level of this system is 72 dB(A).

    Specifications

    External Dimensions

    820720

    100

    6275

    0

    560

    Leg

    spac

    ing

    260

    Leg s

    pacin

    g

    Air inlet8 mm (outer dia.) quick coupling

    410

    927902 25

    Flow direction

    Indicator

    550Leg spacing

    NG box

    1565

    to 1

    635

    815

    to 8

    85Li

    ne h

    eigh

    ts

    Units: mm

    KW9627AP00

    Weighing range: 0.5 to 60NAccuracy (3σ): max. ± 0.01NThroughput: max. 150 products/min

    (Option)(Option)

  • 9

    Pharmaceutical Checkweigher

    Checkweighers for Bags/Pouches, Cartons, and Cases

    Cartons

    Bags/Pouches External Dimensions

    160

    Belt

    wid

    th 610

    495

    Leg

    spac

    ing

    400

    210

    670

    Printer(optional)

    Indicator

    153300

    Tower light(optional)

    236

    18 dia.roller

    700

    to 8

    50Li

    ne h

    eigh

    ts

    410Leg spacing

    60 dia. M20

    105

    18 dia.roller

    Flow direction

    345695

    180

    Large cases

    Units: mm

    Model KWS6206BF06 / KWS6206BP06Weighing range 1.2 to 600NScale interval 0.01NThroughput 1 Maximum 320 products/minAccuracy (3σ) 1 Maximum ± 0.015NDisplay 8.5-inch wide color TFT LCDOperation method Touch panel (Start, Stop, and Home are direct push buttons)Indication range 600.9NPreset memory Maximum 200Classification 2 or 3

    Product size 2Width 20 to 160 mmLength 46 to 320 mmHeight 5 to 320 mm

    Belt speed 15 to 120 m/min

    Power requirements 100 to 120 Vac +10% –15% or 200 to 240 Vac +10% –15%, single phase, 50/60 Hz, 130 VA, rush current 20 A (typ.) (20 ms or less)Mass 60 O

    Environmental conditions 0° to 40°C (variation not to exceed 5°C/h to maintain accuracy), relative humidity 30% to 85%, non-condensingProtection class IP30Exterior F type: Painted P type: Stainless steel (SUS304) (excluding some parts)Standard interfaces USB2.0, 10BASE-T/100BASE-TX Ethernet

    Specifications

    1: Accuracy and throughput depends on the application and the rejector. 2: Varies according to the rejector. Consult us when the product is transparent or semi transparent. Note: The noise level of this system is 70 dB(A) or lower. Note: Optional compliance with FCC Part 15 available.

    External Dimensions

    270

    670

    400

    250

    Belt

    wid

    th

    67049

    5Le

    g sp

    acin

    g

    25 dia.roller

    25 dia.roller

    345695

    M2060 dia.

    180 410Leg spacing

    105

    700

    to 8

    50Li

    ne h

    eigh

    ts

    Tower light(optional) Printer

    (optional)153300

    236

    Indicator

    Flow direction

    Units: mm

    Model KWS5412BF12 / KWS5412BP12Weighing range 12 to 3000NScale interval 0.1NThroughput 1 Maximum 320 products/minAccuracy (3σ) 1 Maximum ± 0.2NDisplay 8.5-inch wide color TFT LCDOperation method Touch panel (Start, Stop, and Home are direct push buttons)Indication range 3009NPreset memory Maximum 200Classification 2 or 3

    Product size 2Width 20 to 250 mmLength 60 to 310 mmHeight 5 to 310 mm

    Belt speed 15 to 120 m/min

    Power requirements 100 to 120 Vac +10% –15% or 200 to 240 Vac +10% –15%, single phase, 50/60 Hz, 250 VA, rush current 20 A (typ.) (20 ms or less)Mass 64 O

    Environmental conditions 0° to 40°C (variation not to exceed 5°C/h to maintain accuracy), relative humidity 30% to 85%, non-condensingProtection class IP30Exterior F type: Painted P type: Stainless steel (SUS304) (excluding some parts)Standard interfaces USB2.0, 10BASE-T/100BASE-TX Ethernet

    Specifications

    1: Accuracy and throughput depends on the application and the rejector. 2: Varies according to the rejector. Consult us when the product is transparent or semi transparent. Note: The noise level of this system is 70 dB(A) or lower. Note: Optional compliance with FCC Part 15 available.

    External Dimensions

    Printer(optional)

    153300

    236

    400

    Belt

    wid

    th

    820

    645

    Leg

    spac

    ing

    500Leg spacing

    39 dia.roller

    650

    M20

    559560 dia.

    700

    to 8

    50Li

    ne h

    eigh

    ts

    Indicator

    Tower light(optional)

    345

    670

    475

    Flow direction

    Units: mm

    Model KWS5728BFNN / KWS5728BPNNWeighing range 60 to 25000NScale interval 2NThroughput 1 Maximum 40 products/minAccuracy (3σ) 1 Maximum ± 2NDisplay 8.5-inch wide color TFT LCDOperation method Touch panel (Start, Stop, and Home are direct push buttons)Indication range 25090NPreset memory Maximum 200Classification 2 or 3

    Product size 2Width 20 to 450 mmLength 88 to 600 mmHeight 5 to 600 mm

    Belt speed 5 to 29 m/min

    Power requirements 100 to 120 Vac +10% –15% or 200 to 240 Vac +10% –15%, single phase, 50/60 Hz, 250 VA, rush current 20 A (typ.) (20 ms or less)Mass 66 O

    Environmental conditions 0° to 40°C (variation not to exceed 5°C/h to maintain accuracy), relative humidity 30% to 85%, non-condensingProtection class IP30Exterior F type: Painted P type: Stainless steel (SUS304) (excluding some parts)Standard interfaces USB2.0, 10BASE-T/100BASE-TX Ethernet

    Specifications

    1: Accuracy and throughput depends on the application and the rejector. 2: Varies according to the rejector. Consult us when the product is transparent or semi transparent. Note: The noise level of this system is 70 dB(A) or lower. Note: Optional compliance with FCC Part 15 available.

    Listed here are just a part of our entire product line. We offer a range of checkweighers to meet different sizes of applications.

    (Option)(Option)

    (Option)(Option)

    (Option)(Option)

    Bags/Cartons/CasesCapsules

    Standing pouchesBottles/Cans

    Other Sachets/Sticks

  • 10

    Pharmaceutical Checkweigher

    External Dimensions

    138

    Attachm

    ent

    spacin

    g

    420

    445

    150

    324

    428 110 290

    328

    4×φ9

    Control unit Measurement unitOperation unit

    Operation attachment unit

    (optional)Terminal resistance unit

    4×φ5

    300

    Attachmentspacing

    Attachmentspacing

    Attachmentspacing

    65

    Attachm

    ent spacin

    g

    3×φ4.3

    178

    Case to have removed a power supply plug

    220

    Weighing frame

    (optional)

    Minimum pitch 33

    300 to

    Lin

    e h

    eig

    hts

    363

    563

    155

    Weighing plate77.5122.5

    140

    211

    350

    Units: mm

    Built-In Multi-Lane Weighing System

    KWS9006AN□□

    ∗ Designed to be integrated with filling/packing equipment.∗ Refer to the Built-In Multi-Lane Weighing System leaflet for detailed

    features.

    Operation unit

    Control unit

    Weighing range: 0.1 to 50NAccuracy (3σ): max. ± 0.002NThroughput: max. 100 products/min (per lane)

    Measurement unit

    (Option)(Option)Specifications

    Model 1 KWS9006AN □□Weighing range 0.1 to 50NScale interval 0.001NThroughput 2 100 products/min per laneAccuracy (3σ) 2 Maximum ± 0.002NDisplay 15-inch color TFT LCDOperation method Touch panel (Start, Stop, Home are direct push bottons)Indication range 50.090NPreset memory Up to 50 Lane Up to 12Power requirements 100 to 120 Vac + 10%–15% or 200 to 240 Vac + 10%–15%, single phase, 50/60 Hz, rush current 12 A (typ.) (20 ms or less)Mass Operation unit: 4 O; Control unit: 6 O; Measurement unit: 1.5 OEnvironmental conditions 0 to 40℃ (variation not to exceed 5 ℃/h to maintain accuracy), relative humidity 30% to 85%, non-condensingProtection class Operation unit: IP50; Control unit: IP20; Measurement unit: IP50Exterior Operation unit: SUS; Control unit: aluminum; Measurement unit: SUSData output USB port (USB2.0), Ethernet interface (10BASE-T, 100BASE-TX)External I/F I/O contact, serial or CC-Link

    1: □ indicates the number of lane.2: Depends on the product to be weighed.Note: Strain gauge load cell is also available. Contact our sales representatives. Note: This device complies with part 15 of the FCC Rules.

    Note: Dimensions of weighing unit is for 12 lanes.Note: Shapes of weighing table and weighing table stand depend on the specifications. Contact us for detailed dimensions.

    Other Capsules

    Standing pouchesBottles/Cans

    Bags/Cartons/CasesSachets/Sticks

  • 11

    Note

    KWS9006AN□□

  • CheckweigherPharmaceutical

    April 2014

    CAT. NO. K3192-B-1 2014-4 (ddc) Printed in Japan

    1001 Cambridge Drive Elk Grove Village, IL 60007-2453

    Phone (847)419-XRAY(9729) Fax (847)537-8266

    http://www.detectionperfection.com

    ISO14001 CERTIFICATE No.JQA-EM0210

    ISO 9001 CERTIFICATE No.JQA-0566

    Anritsu Industrial Solutions USA Inc.

    ANRITSU INDUSTRIAL SOLUTIONS CO., LTD. 2014

    In addition to daily inspection, an annual maintenance check should be carried out.

    To ensure proper operation, read the Operation Manual before using the machine.

    Specifications are subject to change without notice.

    No part of this catalog may be reproduced without our permission.

    Printed on Recycled Paper

    Some products shown in this catalog may not be available in your country or region. Contact our sales representatives for details.