picasso custom specification data · iic fitting range color guide standard colors shell colors...
TRANSCRIPT
Matrices: 115/50, 120/60, 130/70 Battery Size: 13
FO
G 5
0 (
dB
)
Frequency (Hz)
FOG 50OSPL90
OS
PL
90
(d
BS
PL
)
100 1000 10000
80
70
60
90
100
110
120
13080
70
60
50
40
30
20
10
FO
G 5
0 (
dB
)
Frequency (Hz)
FOG 50OSPL90
OS
PL
90
(d
BS
PL
) 100 1000 10000
80
70
60
90
100
110
120
13080
70
60
50
40
30
20
10
FO
G 5
0 (
dB
)
Frequency (Hz)
FOG 50OSPL90
OS
PL
90
(d
BS
PL
)
100 1000 10000
100
90
80
110
120
130
140
150100
90
80
70
60
50
40
30
Matrix 115/50
Matrix 120/60
Matrix 130/70
ITEIN-THE-EAR
Picasso i2400 | i2000 | i1600
Color GuideFaceplate Colors
Medium Brown
Dark Brown
PinkChestnut Light Brown
Shell Colors
Blue/Red
PinkClear Light Brown
*Results will vary based on wireless usage.
Measurement ANSI/IEC 2cc Coupler
IEC OES Coupler
Peak OSPL90 (dB SPL) 115-130 124-137
HFA OSPL90 (dB SPL) 109-123 N/A
RTF OSPL90 (dB SPL) N/A 110-130
Peak Gain (dB) 50-70 60-77
HFA Full-On Gain (dB) 46-64 N/A
RTF Full-On Gain (dB) N/A 46-68
Frequency Range (Hz) <100-8200 <100-8900
Reference Test Freq. (kHz) N/A 1.6
HFA Frequencies (kHz) 1.0,1.6,2.5 N/A
Reference Test Gain (dB) 32-46 35-55
Equivalent Input Noise (dB) <25 <25
Harmonic Distortion
500 Hz (%) <3 <3
800 Hz (%) <3 <3
1600 Hz (%) <3 <3
Induction Coil Sensitivity
HFA SPLITS (ANSI) (dB SPL) 95-108 N/A
MASL (IEC) (dB SPL) N/A 83-106
ANSI/IEC Battery Current (mA)
1.3-1.5* 1.3-1.7*
Idle Current (mA) 1.3* 1.3*
Estimated Battery Life for 16-Hour Day
13 Zinc Air (days) 13-16* 13-16*
Tinnitus Therapy Stimulus
Max RMS Output (dB SPL) 87
Weighted RMS Output Level (dB SPL) 87
Max 1/3 Octave Output (dB SPL) 87
ITE Gain Data
Hea
rin
g L
evel
in d
B (
HL
)
Frequency (Hz)
0
10
20
30
40
50
60
70
80
90
100
110
120
130
250 500 1K 2K 6K4K 8K
ITE 50
ITE 60
ITE 70
Fitting Range
Patient Features• Tinnitus Technology• Wireless Connectivity• Telecoil Option
Accessory Compatibility
• SurfLink Mini Mobile System• SurfLink Remote Microphone 2• SurfLink Media 2
• SurfLink Mobile 2• SurfLink Remote• SurfLink Programmer
Matrices: 110/40, 115/50, 120/60, 130/70 Battery Size: 312
HSHALF SHELL
Measurement ANSI/IEC 2cc Coupler
IEC OES Coupler
Peak OSPL90 (dB SPL) 110-130 122-139
HFA OSPL90 (dB SPL) 106-124 N/A
RTF OSPL90 (dB SPL) N/A 106-130
Peak Gain (dB) 40-70 54-79
HFA Full-On Gain (dB) 36-64 N/A
RTF Full-On Gain (dB) N/A 37-68
Frequency Range (Hz) <100-9600 <100-9600
Reference Test Freq. (kHz) N/A 1.6
HFA Frequencies (kHz) 1.0,1.6,2.5 N/A
Reference Test Gain (dB) 29-47 30-55
Equivalent Input Noise (dB) <25 <25
Harmonic Distortion
500 Hz (%) <3 <3
800 Hz (%) <3 <3
1600 Hz (%) <3 <3
Induction Coil Sensitivity
HFA SPLITS (ANSI) (dB SPL) 89-108 N/A
MASL (IEC) (dB SPL) N/A 71-105
ANSI/IEC Battery Current (mA)
1.3-1.5* 1.3-1.6*
Idle Current (mA) 1.3* 1.3*
Estimated Battery Life for 16-Hour Day
312 Zinc Air (days) 7-10* 7-10*
Tinnitus Therapy Stimulus
Max RMS Output (dB SPL) 87
Weighted RMS Output Level (dB SPL) 87
Max 1/3 Octave Output (dB SPL) 87
HS Gain Data
HS 50
HS 40
HS 60
HS 70
Hea
rin
g L
evel
in d
B (
HL
)
Frequency (Hz)
0
10
20
30
40
50
60
70
80
90
100
110
120
130
250 500 1K 2K 6K4K 8KPicasso i2400 | i2000 | i1600
Color GuideFaceplate Colors
Medium Brown
Dark Brown
PinkChestnut Light Brown
Shell Colors
Blue/Red
PinkClear Light Brown
*Results will vary based on wireless usage.
FO
G 5
0 (
dB
)
Frequency (Hz)
FOG 50OSPL90
OS
PL
90
(d
BS
PL
)
100 1000 10000
80
70
60
90
100
110
120
13080
70
60
50
40
30
20
10
Matrix 115/50
FO
G 5
0 (
dB
)
Frequency (Hz)
FOG 50OSPL90
OS
PL
90
(d
BS
PL
)
100 1000 10000
80
70
60
90
100
110
120
13080
70
60
50
40
30
20
10
Matrix 120/60
FO
G 5
0 (
dB
)
Frequency (Hz)
FOG 50OSPL90
OS
PL
90
(d
BS
PL
)
100 1000 10000
100
90
80
110
120
130
140
150100
90
80
70
60
50
40
30
Matrix 130/70
Fitting Range
Patient Features• Tinnitus Technology• Wireless Connectivity• Telecoil Option
FO
G 5
0 (
dB
)
Frequency (Hz)
FOG 50OSPL90
OS
PL
90
(d
BS
PL
)
100 1000 10000
80
70
60
90
100
110
120
13080
70
60
50
40
30
20
10
Matrix 110/40
Accessory Compatibility • SurfLink Mini Mobile System• SurfLink Remote Microphone 2• SurfLink Media 2
• SurfLink Mobile 2• SurfLink Remote• SurfLink Programmer
Matrices: 110/40, 115/50, 120/60, 130/70 Battery Size: 312
ITCIN-THE-CANAL
ITC 50
ITC 40
ITC 60
ITC 70
Picasso i2400 | i2000 | i1600
Color GuideFaceplate Colors
Medium Brown
Dark Brown
PinkChestnut Light Brown
Shell Colors
Blue/Red
PinkClear Light Brown
*Results will vary based on wireless usage.
Measurement ANSI/IEC 2cc Coupler
IEC OES Coupler
Peak OSPL90 (dB SPL) 110-130 122-139
HFA OSPL90 (dB SPL) 106-124 N/A
RTF OSPL90 (dB SPL) N/A 106-130
Peak Gain (dB) 40-70 54-79
HFA Full-On Gain (dB) 36-64 N/A
RTF Full-On Gain (dB) N/A 37-68
Frequency Range (Hz) <100-9600 <100-9600
Reference Test Freq. (kHz) N/A 1.6
HFA Frequencies (kHz) 1.0,1.6,2.5 N/A
Reference Test Gain (dB) 29-47 30-55
Equivalent Input Noise (dB) <25 <25
Harmonic Distortion
500 Hz (%) <3 <3
800 Hz (%) <3 <3
1600 Hz (%) <3 <3
Induction Coil Sensitivity
HFA SPLITS (ANSI) (dB SPL) 89-108 N/A
MASL (IEC) (dB SPL) N/A 71-105
ANSI/IEC Battery Current (mA)
1.3-1.5* 1.3-1.6*
Idle Current (mA) 1.3* 1.3*
Estimated Battery Life for 16-Hour Day
312 Zinc Air (days) 7-10* 7-10*
Tinnitus Therapy Stimulus
Max RMS Output (dB SPL) 87
Weighted RMS Output Level (dB SPL) 87
Max 1/3 Octave Output (dB SPL) 87
ITC Gain Data
Hea
rin
g L
evel
in d
B (
HL
)
Frequency (Hz)
0
10
20
30
40
50
60
70
80
90
100
110
120
130
250 500 1K 2K 6K4K 8K
Fitting Range
Patient Features• Tinnitus Technology• Wireless Connectivity• Telecoil Option
SurfLink Accessories• SurfLink Mini Mobile System• SurfLink Remote Microphone 2• SurfLink Media 2
• SurfLink Mobile 2• SurfLink Remote• SurfLink Programmer
FO
G 5
0 (
dB
)
Frequency (Hz)
FOG 50OSPL90
OS
PL
90
(d
BS
PL
)
100 1000 10000
80
70
60
90
100
110
120
13080
70
60
50
40
30
20
10
Matrix 110/40
FO
G 5
0 (
dB
)
Frequency (Hz)
FOG 50OSPL90
OS
PL
90
(d
BS
PL
) 100 1000 10000
80
70
60
90
100
110
120
13080
70
60
50
40
30
20
10
Matrix 115/50
FO
G 5
0 (
dB
)
Frequency (Hz)
FOG 50OSPL90
OS
PL
90
(d
BS
PL
)
100 1000 10000
80
70
60
90
100
110
120
13080
70
60
50
40
30
20
10
Matrix 120/60
FO
G 5
0 (
dB
)
Frequency (Hz)
FOG 50OSPL90
OS
PL
90
(d
BS
PL
)
100 1000 10000
100
90
80
110
120
130
140
150100
90
80
70
60
50
40
30
Matrix 130/70
Matrices: 110/40, 115/50, 120/60, 130/70 Battery Size: 312, 10
CICCOMPLETELY- IN-CANAL
CIC 50
CIC 40
CIC 60
CIC 70
Hea
rin
g L
evel
in d
B (
HL
)
Frequency (Hz)
0
10
20
30
40
50
60
70
80
90
100
110
120
130
250 500 1K 2K 6K4K 8KPicasso i2400 | i2000 | i1600
Color GuideFaceplate Colors
Medium Brown
Dark Brown
PinkChestnut Light Brown
Shell Colors
Blue/Red
PinkClear Light Brown
*Results will vary based on wireless usage.
Measurement ANSI/IEC 2cc Coupler
IEC OES Coupler
Peak OSPL90 (dB SPL) 110-130 120-137
HFA OSPL90 (dB SPL) 106-124 N/A
RTF OSPL90 (dB SPL) N/A 110-130
Peak Gain (dB) 40-70 51-78
HFA Full-On Gain (dB) 36-63 N/A
RTF Full-On Gain (dB) N/A 44-68
Frequency Range (Hz) <100-9400 <100-9700
Reference Test Freq. (kHz) N/A 1.6
HFA Frequencies (kHz) 1.0,1.6,2.5 N/A
Reference Test Gain (dB) 29-47 35-55
Equivalent Input Noise (dB) <25 <25
Harmonic Distortion
500 Hz (%) <3 <3
800 Hz (%) <3 <3
1600 Hz (%) <3 <3
Induction Coil Sensitivity
HFA SPLITS (ANSI) (dB SPL) N/A N/A
MASL (IEC) (dB SPL) N/A N/A
ANSI/IEC Battery Current (mA)
1.2-1.5* 1.2-1.5*
Idle Current (mA) 1.2-1.3* 1.2-1.3*
Estimated Battery Life for 16-Hour Day
312 Zinc Air (days) 7-10* 7-10*
10 Zinc Air (days) 4-7* 4-7*
Tinnitus Therapy Stimulus
Max RMS Output (dB SPL) 87
Weighted RMS Output Level (dB SPL) 87
Max 1/3 Octave Output (dB SPL) 87
CIC Gain Data
Fitting Range
Patient Features• Tinnitus Technology• Wireless Connectivity
Accessory Compatibility
• SurfLink Mini Mobile System• SurfLink Remote Microphone 2• SurfLink Media 2
• SurfLink Mobile 2• SurfLink Remote• SurfLink Programmer
FO
G 5
0 (
dB
)
Frequency (Hz)
FOG 50OSPL90
OS
PL
90
(d
BS
PL
)
100 1000 10000
80
70
60
90
100
110
120
13080
70
60
50
40
30
20
10
Matrix 110/40
FO
G 5
0 (
dB
)
Frequency (Hz)
FOG 50OSPL90
OS
PL
90
(d
BS
PL
) 100 1000 10000
80
70
60
90
100
110
120
13080
70
60
50
40
30
20
10
Matrix 115/50
FO
G 5
0 (
dB
)
Frequency (Hz)
FOG 50OSPL90
OS
PL
90
(d
BS
PL
)
100 1000 10000
80
70
60
90
100
110
120
13080
70
60
50
40
30
20
10
Matrix 120/60
FO
G 5
0 (
dB
)
Frequency (Hz)
FOG 50OSPL90
OS
PL
90
(d
BS
PL
)
100 1000 10000
100
90
80
110
120
130
140
150100
90
80
70
60
50
40
30
Matrix 130/70
CIC 50
CIC 40
CIC 60
CIC 70
Hea
rin
g L
evel
in d
B (
HL
)
Frequency (Hz)
0
10
20
30
40
50
60
70
80
90
100
110
120
130
250 500 1K 2K 6K4K 8K
Fitting Range
Patient Features• Tinnitus Technology
Matrices: 110/40, 115/50, 120/60, 130/70 Battery Size: 312, 10
Measurement ANSI/IEC 2cc Coupler
IEC OES Coupler
Peak OSPL90 (dB SPL) 110-130 120-137
HFA OSPL90 (dB SPL) 106-124 N/A
RTF OSPL90 (dB SPL) N/A 110-130
Peak Gain (dB) 40-70 51-78
HFA Full-On Gain (dB) 36-63 N/A
RTF Full-On Gain (dB) N/A 44-68
Frequency Range (Hz) <100-9400 <100-9700
Reference Test Freq. (kHz) N/A 1.6
HFA Frequencies (kHz) 1.0,1.6,2.5 N/A
Reference Test Gain (dB) 29-47 35-55
Equivalent Input Noise (dB) <25 <25
Harmonic Distortion
500 Hz (%) <3 <3
800 Hz (%) <3 <3
1600 Hz (%) <3 <3
Induction Coil Sensitivity
HFA SPLITS (ANSI) (dB SPL) N/A N/A
MASL (IEC) (dB SPL) N/A N/A
ANSI/IEC Battery Current (mA)
1.1-1.3 1.1-1.3
Idle Current (mA) 1.0-1.1 1.0-1.1
Estimated Battery Life for 16-Hour Day
312 Zinc Air (days) 7-10 7-10
10 Zinc Air (days) 4-7 4-7
Tinnitus Therapy Stimulus
Max RMS Output (dB SPL) 87
Weighted RMS Output Level (dB SPL) 87
Max 1/3 Octave Output (dB SPL) 87
CIC Gain Data
FO
G 5
0 (
dB
)
Frequency (Hz)
FOG 50OSPL90
OS
PL
90
(d
BS
PL
)
100 1000 10000
80
70
60
90
100
110
120
13080
70
60
50
40
30
20
10
FO
G 5
0 (
dB
)
Frequency (Hz)
FOG 50OSPL90
OS
PL
90
(d
BS
PL
) 100 1000 10000
80
70
60
90
100
110
120
13080
70
60
50
40
30
20
10
FO
G 5
0 (
dB
)
Frequency (Hz)
FOG 50OSPL90
OS
PL
90
(d
BS
PL
)
100 1000 10000
100
90
80
110
120
130
140
150100
90
80
70
60
50
40
30
CICCOMPLETELY- IN-CANAL
Picasso 2400 | 2000 | 1600
Color GuideFaceplate Colors
Medium Brown
Dark Brown
PinkChestnut Light Brown
Shell Colors
Blue/Red
PinkClear Light Brown
Matrix 110/40
Matrix 115/50
FO
G 5
0 (
dB
)
Frequency (Hz)
FOG 50OSPL90
OS
PL
90
(d
BS
PL
)
100 1000 10000
80
70
60
90
100
110
120
13080
70
60
50
40
30
20
10
Matrix 120/60
Matrix 130/70
Fitting Range
IIC
Color GuideStandard Colors Shell Colors
*Results will vary based on wireless usage.
Picasso i2400
PinkDark Brown
Medium Brown
Black Light Brown
Black
Hea
rin
g L
evel
in d
B (
HL
)
Frequency (Hz)
0
10
20
30
40
50
60
70
80
90
100
110
120
250 500 1K 2K 8K4K
Matrices: 110/35, 110/40, 115/50 Battery Size: 10
FO
G 5
0 (
dB
)
Frequency (Hz)
FOG 50OSPL90
OS
PL
90
(d
BS
PL
)
70
60
80
90
100
110
120
130
10
20
30
40
50
60
70
80
100 1000 10000
INVISIBLE- IN-CANALIIC 40
IIC 35
IIC 50
Measurement ANSI/IEC 2cc Coupler
IEC OES Coupler
Peak OSPL90 (dB SPL) 110-115 120-125
HFA OSPL90 (dB SPL) 106-109 N/A
RTF OSPL90 (dB SPL) N/A 110-114
Peak Gain (dB) 35-50 45-61
HFA Full-On Gain (dB) 30-46 N/A
RTF Full-On Gain (dB) N/A 39-46
Frequency Range (Hz) <100-9400 <100-9700
Reference Test Freq. (kHz) N/A 1.6
HFA Frequencies (kHz) 1.0,1.6,2.5 N/A
Reference Test Gain (dB) 29-32 32-37
Equivalent Input Noise (dB) <25 <25
Harmonic Distortion
500 Hz (%) <3 <3
800 Hz (%) <3 <3
1600 Hz (%) <3 <3
Induction Coil Sensitivity
HFA SPLITS (ANSI) (dB SPL) N/A N/A
MASL (IEC) (dB SPL) N/A N/A
ANSI/IEC Battery Current (mA) 1.2-1.5* 1.2-1.4*
Idle Current (mA) 1.2* 1.2*
Estimated Battery Life for 16-Hour Day
10 Zinc Air (days) 4-7* 4-7*
Tinnitus Therapy Stimulus
Max RMS Output (dB SPL) 87
Weighted RMS Output Level (dB SPL) 87
Max 1/3 Octave Output (dB SPL) 87
Patient Features• Tinnitus Technology• Wireless Connectivity
Accessory Compatibility • SurfLink Mini Mobile System• SurfLink Remote Microphone 2• SurfLink Media 2
• SurfLink Mobile 2• SurfLink Remote• SurfLink Programmer
FO
G 5
0 (
dB
)
Frequency (Hz)
FOG 50OSPL90
OS
PL
90
(d
BS
PL
)
60
70
80
90
100
110
120
130
15
25
35
45
55
65
75
100 1000 10000
Matrix 110/35
FO
G 5
0 (
dB
)
Frequency (Hz)
FOG 50OSPL90
OS
PL
90
(d
BS
PL
)
10
20
30
40
50
60
70
80
100 1000 10000 60
70
80
90
100
110
120
130
Matrix 110/40
Matrix 115/50
IIC Gain Data
Matrices: 110/35, 110/40, 115/50 Battery Size: 10
FO
G 5
0 (
dB
)
Frequency (Hz)
FOG 50OSPL90
OS
PL
90
(d
BS
PL
)
70
60
80
90
100
110
120
130
10
20
30
40
50
60
70
80
100 1000 10000
Matrix 115/50
FO
G 5
0 (
dB
)
Frequency (Hz)
FOG 50OSPL90
OS
PL
90
(d
BS
PL
)
10
20
30
40
50
60
70
80
100 1000 10000 60
70
80
90
100
110
120
130
Matrix 110/40
FO
G 5
0 (
dB
)
Frequency (Hz)
FOG 50OSPL90
OS
PL
90
(d
BS
PL
)
60
70
80
90
100
110
120
130
15
25
35
45
55
65
75
100 1000 10000
Matrix 110/35
IICINVISIBLE- IN-CANAL
IIC 35
IIC 40
IIC 50
Picasso 2400
Color GuideFaceplate Colors
Medium Brown
Dark Brown
Black PinkLight Brown
Shell Colors
Black
© 2019 Starkey. All Rights Reserved. 3/19 SPEC2874-01-EE-ST
Hea
rin
g L
evel
in d
B (
HL
)
Frequency (Hz)
0
10
20
30
40
50
60
70
80
90
100
110
120
250 500 1K 2K 8K4K
Measurement ANSI/IEC 2cc Coupler
IEC OES Coupler
Peak OSPL90 (dB SPL) 110-115 120-125
HFA OSPL90 (dB SPL) 106-109 N/A
RTF OSPL90 (dB SPL) N/A 110-114
Peak Gain (dB) 35-50 45-61
HFA Full-On Gain (dB) 30-46 N/A
RTF Full-On Gain (dB) N/A 39-46
Frequency Range (Hz) <100-9400 <100-9700
Reference Test Freq. (kHz) N/A 1.6
HFA Frequencies (kHz) 1.0,1.6,2.5 N/A
Reference Test Gain (dB) 29-32 32-37
Equivalent Input Noise (dB) <25 <25
Harmonic Distortion
500 Hz (%) <3 <3
800 Hz (%) <3 <3
1600 Hz (%) <3 <3
Induction Coil Sensitivity
HFA SPLITS (ANSI) (dB SPL) N/A N/A
MASL (IEC) (dB SPL) N/A N/A
ANSI/IEC Battery Current (mA)
1.1-1.2 1.1-1.2
Idle Current (mA) 1.0 1.0
Estimated Battery Life for 16-Hour Day
10 Zinc Air (days) 4-7 4-7
Tinnitus Therapy Stimulus
Max RMS Output (dB SPL) 87
Weighted RMS Output Level (dB SPL) 87
Max 1/3 Octave Output (dB SPL) 87
Fitting Range
IIC Gain Data
Patient Features• Tinnitus Technology