71
3 POS-E-KON TM Pos-E-Kon Table of Contents A 10A 3/4, 10, 16, 32 16, 17 B 16A 6, 10, 16, 24, 32, 48 18-21 C 35A 6, 12 22, 23 D 10A 7/8, 15, 25, 40, 50, 64, 80, 128 24-27 DD 10A 24, 42, 72, 108, 144, 216 28-31 K 16A/80A 8 + 4, 16 + 8 32, 33 V 16A 3, 6, 10, 16, 20, 26, 32 (all +2) 34-37 T 16A/200°C 6, 10, 16, 24 (200°C) 38, 39 M Spec Modular 40-50 FAQs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 The System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Insert Selector Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6, 7 Hood and Base Housings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Using the Catalogue. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-13 Catalogue Numbering System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Series Locator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Reference and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Fiber Optic Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 Series Amperage Contacts + G Page @ 600VAC

Upload: others

Post on 27-Jan-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

  • 3

    POS-E-KONTM

    Pos-E-Kon™

    Table of Contents

    A 10A 3/4, 10, 16, 32 16, 17

    B 16A 6, 10, 16, 24, 32, 48 18-21

    C 35A 6, 12 22, 23

    D 10A 7/8, 15, 25, 40, 50, 64, 80, 128 24-27

    DD 10A 24, 42, 72, 108, 144, 216 28-31

    K 16A/80A 8 + 4, 16 + 8 32, 33

    V 16A 3, 6, 10, 16, 20, 26, 32 (all +2) 34-37

    T 16A/200°C 6, 10, 16, 24 (200°C) 38, 39

    M Spec Modular 40-50

    FAQs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4The System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Insert Selector Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6, 7Hood and Base Housings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Using the Catalogue. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-13Catalogue Numbering System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Series Locator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Reference and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51Fiber Optic Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72

    Series Amperage Contacts + G Page@ 600VAC

    1-5.pdf 3 1/5/2012 2:45:05 PM1-76.pdf 3 1/6/2012 10:52:54 AM

  • Pos-E-Kon™

    Frequently Asked Questions

    4

    Answers to the Ques tions Most Frequently Askedby Users of Pos-E-Kon Connectors

    International Standards, World wide Use

    How?

    Why?

    Rectangular Circuit In ter con nec tions• Best use of space for multiple con tacts in heavy

    duty housings.• Easy to assemble with many different insert

    options. • Best fit for easy access in panels, machinery,

    and en clo sures.• Sealed connector with quick disconnect han-

    dles.• Wide variety of circuit pos si bil i ties from stan-

    dard items.• Solid or stranded wire in fixed or portable

    applications.

    Who? • Machine tool OEMs.• Material handling equipment OEMs.• Ro bot ics systems OEMs and installations.• Packaging ma chin ery OEMs and facilities.• Control panels and PLC systems.• Mold ing, assembly, or line machinery OEMs

    and facilities.• Con struc tion, mining, and weld ing apparatus.• Carnival applications.

    What? • Servo controls.• Sensing and feedback loops.• Conveyor and process controls.• Low power, DC, or logic systems.• Com bi na tion power systems and other circuits.• Mod u lar controls in clud ing fiber-optics connections.

    Where? Worldwide agency approvals and applications• DIN VDE 0627/86, 0110/02.79, and 0110-1/04.97.• IEC 60.664-1, DIN/IEC 512.• UL recognized (E215386) and CSA certified • Pro tec tion classes IP44 through IP65 per IEC 529.• Component use in CE marked equipment OK per

    IEC Council Directive July 1999, 73/23/EEC.

    • Available from Thomas & Betts–Pos-E-Kon authorized distributors.• For sales and service, contact your Thomas & Betts Regional Sales Office. Refer to back cover

    for contact information.

    1-5.pdf 4 1/5/2012 2:45:05 PM1-76.pdf 4 1/6/2012 10:52:54 AM

  • 5

    Pos-E-Kon™

    The System

    POS-E-KONTM

    As Easy As 1. 2. 3. 4.

    1. Hood• Separable housing for inserts.• Top or side conduit/wire entry.• Standard locking posts, dual or single.• Locks to Panel Base, Box Base or in-line

    Coupler Hood

    2. Base Housing (or Coupler Hood)• Surface wall mount box base (shown).• Panel Base for through-panel access.• Coupler Hood mating for portable use.• Single or dual “Lever” locking.

    3. Male Insert• Male contact carrier body.• Screw terminal contacts (pins with wire

    protection saddles) or crimp terminatedpins.

    4. Female Insert• Female contact carrier.• Screw terminal contacts (sleeves with

    wire protection saddles) or crimp terminated sleeves.

    The Basic System: How to Build for an ApplicationStep 1 —Maximum voltage and amperage requirements (300V or 600V classes, 10-80 amps).Step 2 —Number of contacts or circuits needed.Step 3 —Choose wire termination style; screw terminal or crimp contacts. Select series from charts.Step 4 —Base (or Coupler) and Hood construction/mating selection per series (single or double levers).

    HOOD

    BASE (OR COUPLER HOOD)

    MALE INSERT

    FEMALEIN SERT

    CABLE ENTRYWITH FITTING

    CABLE ENTRY WITH FITTING

    DIN Standard Configurations

    • Most inserts and housings are interface compatible with other DIN standard lines.

    • Pos-E-Kon construction includes standard NPT conduit adapters for hoods and bases, with manyoptions available. DIN standard hoods and bases may have “Euro Style” Pg fittings (or none) included unless specially ordered.

    1-5.pdf 5 1/5/2012 2:45:05 PM1-76.pdf 5 1/6/2012 10:52:54 AM

  • Pos-E-Kon™

    Pos-E-Kon Insert Selector Chart

    6

    S — Screw TerminalsC — Crimp ContactsF — Fiber Optic (POF)A — Terminal Block Wiring Adapter

    Screw Terminal / Insert Types (Integral Contacts)

    10 - 16A A, B, V, T

    35A C

    16 - 80A K

    16AA & B

    10AD & DD

    POFD & M

    Signal 1.5 AM-Coax

    50 AmpM3

    16 AmpM 4/5

    20 AmpM5

    5 AmpM20

    Crimp Terminal / Insert Types (Crimp Contacts)

    • All crimp types represented require contacts ordered separately.• Each section contains hand crimp tool selection notes.

    Thermocouple compensated contacts (crimp) also available (Fe and Cu) for A & B series inserts.Contact your Thomas & Betts Regional Sales Office. See back cover for contact information.

    10AD & DD

    16A A & B

    5-50A M

    Screw termination is used for ease of assembly, some heavier gauge wires plusease of maintenance. No tooling beyond a screwdriver and wire strippers isrequired.

    Crimp terminals offer solid, thermally cool, vibration resistant terminations for OEMequipment and critical applications. Better for smaller AWG sizes also. Crimp toolsare noted in each section.

    NEW

    Select the number of contacts – All inserts have separate ground contacts

    AMPS VOLTS Series 3 4 6 7 8 10 12 15 16 20 24 25 26 32 40 42 48 50-216

    10 50 D C, F

    10 600 A S S

    16 600 A S, C S, C S, C

    16 600 B S, C, A S, C, A S, C, A S, C, A S, C S, C

    35 600 C S S

    10 600 D C, F C, F C, F C, F, A C, F, A (64)

    10 600 DD C, F C, F C, F

    80/16 600 K S S Combination Inserts: 4 power (80A) + 8 control (16A), 8 power (80A) + 16 control (16A).

    16-T 600 T S S S S High Temp (200°C)

    16-V 600 V S, C S, C S, C S, C S, C S, C S, C Includes 2 Pilot Contacts

    Modular 600 M Configure to individual specs. Options: Fiber Optic, Power and Control Pin selections in sectional inserts. Contact Tech Service for Information.

    6-20.pdf 1 1/5/2012 2:45:30 PM1-76.pdf 6 1/6/2012 10:52:54 AM

  • 7

    Pos-E-Kon™

    Insert Selection

    POS-E-KONTM

    • Integral screw terminal contacts provide for easy terminal wiring, fast assembly.

    • Standard wire protection saddles prevent cutting of strands during assembly.

    • Provides reliable connections for long-termconfigurations.

    • Contact sizes accommodate wiring from 12 - 20 AWG.

    • Made of durable glass fiber-filled thermoplastic. • Contact numbers clearly marked for easy identification.• Easily installed (male or female) in either hoods or bases using captive mounting screws.

    WAR, Right Ground StrapWAL, Left Ground Strap

    • Allow for measuring of circuit while in operation.• Provide easy connections in panel mounting configurations.• Labels available for easy identification of circuits.• Can be mounted on DIN rails by using snap-on mount feet.• Used in switch cabinets, panel enclosures or mounted in panel

    base housings – see B and D series.

    WAM1 – Insert Strip Blank – WAM1BInsert Strip Nos. 1-64 – WAM1N64Insert Strip Letters A-Z – WAM1AZ

    WAM2 – Insert Strip Blank – WAM2BInsert Strip Nos. 1-64 – WAM2N64Insert Strip Letters A-Z – WAM2AZ

    WAM1 Marker Tab ClipsSnap-in formed label holder tabs allow terminalidentification for B Series.

    WAM2 Marker Tab ClipsSnap-in formed label holder tabs allow terminalidentification for D Series.

    Terminal Block Wiring Adapters

    DIN Mounting Foot FE807TB

    Screw Terminal Inserts Crimp Terminal Inserts

    6-20.pdf 2 1/5/2012 2:45:30 PM1-76.pdf 7 1/6/2012 10:52:54 AM

  • Pos-E-Kon™

    Hood and Base Housings

    8

    • Rugged cast aluminum hoods and bases: Maximum performance in many operating conditions.

    • Various hood heights available: Easier assembly and wiring with low, high and standard profiles.

    • Corrosion resistant finishes: Optional special materials extend life in corrosive conditions.

    • Locking possibilities include single locking system and double locking system.

    • Complete selection: Flexible product designs (see Hood/Base Size Cross Reference Chart below).

    • Dust Covers and More: See Adapters, pp. 9-10 and Covers p. 10 (or Bases w/Covers) available inmost series (Accessories p. 66 ) see pp. 67-68 for all Adapter Plates.

    • Custom Configurations: Multiple conduit entry/sizes and other configurations available to spec.

    Cross Reference

    Applications Standard Hood/Base Housings

    AMPS VOLTS Series A4 A10 A16 A32 B6 B10 B16 B24 B32 B48

    10A 50 D D8

    10A 600 A A3, A4

    16A 600 A A10 A16 A32

    16A 600 B B6 B10 B16 B24 B32 B48

    35A 600 C C6 C12

    10A 600 D D7 D15 D25 D50 D40 D64 D80 D128

    10A 600 DD DD24 DD42 DD72 DD108 DD144 DD216

    80/16A 600 K K4/8 K8/16

    ModularM 600 M M, B6 M, B10 M, B16 M, B24 M, B16 M, B24

    16A-Tn 600 T T6 T10 T16 T24

    16A-V* 600 V V3 V6 V10 V32

    * Special isolation design allows additional control circuit capability.n Special high temperature series in Cu-Free Aluminum with special green epoxy powder-coat, Viton® seals.†† Viton is a trademark of DuPont Dow Elastomers.

    Applications Special Series Hood/Base Housings

    Box Base Housing w/Single leverand spring cover. New: metal spring covers now available for B series, wherenoted.

    INSERTS

    Panel Base Side Cable Entry

    Box Base Top Cable Entry

    6-20.pdf 3 1/5/2012 2:45:30 PM1-76.pdf 8 1/6/2012 10:52:54 AM

  • 9

    Pos-E-Kon™

    Using the Catalogue: Series layout

    POS-E-KONTM

    STANDARDBASES

    STANDARDHOODS

    Portable Service

    COUPLER HOODS

    Reverse Locking

    LEVER HOODS

    POST BASES

    1. For each series, select size (number of contacts) from the chart on the left hand page (selectedinserts), then look at corresponding right hand page columns.

    2. Vertical columns note single or double locking systems available (double locking usually preferable).

    3. Select base housings for mounting and/or function: conduit/cable entry, through-panel access, in-line coupler or reversed locking as shown (note profile height options).

    4. Select side or top entry hoods as shown (note profile height options).

    5. Review conduit and cable entry options (standard NPT adapter sizes for each series).

    Note: M Series (layout) groups interior options, followed by base selection options.

    Each Right Hand Page Shows:

    HOODTO

    BASE

    HOODTO

    BASE

    HOODTO

    COUPLER

    6-20.pdf 4 1/5/2012 2:45:31 PM1-76.pdf 9 1/6/2012 10:52:54 AM

  • Pos-E-Kon™

    Accessories

    10

    Sub-Miniature (DB) Adapter Plates• Connect test and diagnostic equipment to control circuits.• Panel base, box housing base, or any hood installation (ribbon

    cable entry hoods available).• Industry standard sizes.• Dust covers for protection recommended.• 9, 15, 25, 37 and 50 series.

    B24 Insert Mounting Adapter Plates• Allow housing standardization for multiple applications.• B24 footprint fit to single B6, B10, B16 inserts.• Rugged thermoplastic.• Fits standard B24 hoods and bases.

    Cover Plates• Allow custom connections for drill-and-install work.• Blank plate for expansion.• All standard hood/base sizes supported.

    See page 67 for ordering information and dimensions.

    See page 68 for ordering information and dimensions.

    • Single or double locking options by series.• Separate covers or fixed mount hinged types.• New metal fixed mount hinged covers for B series bases now

    available in select sizes.• Separate or fixed covers protect contacts when not in use or

    while unmated.

    Dust Covers (thermoplastic) Hinged Covers (thermoplastic or metal)

    6-20.pdf 5 1/5/2012 2:45:32 PM1-76.pdf 10 1/6/2012 10:52:55 AM

  • 11

    Pos-E-Kon™

    Accessories

    POS-E-KONTM

    Cord Grip Fittings• Both NPT and Pg thread styles.• New thermoplastic sealing glands in NPT, Pg

    and new ISO threads – for retrofit or original specification.

    • More options than shown are available. See our Industrial Fittings Catalogues. (Shown in grey. Black also available.)

    Ribbon or Flat Cable Sealing• Single, double or triple cable entry options.• Hoods must be specified as ribbon cable

    entry style.• Sealing sets available separately.• Box base housing sealing sets also available.

    Hood Seal SetBox Base Series Set

    Wire and Cable Entry Options

    Strain Relief Fittings• Sheathed industrial multi-conductor cables

    usage.• Options cover many installation needs.• Special constructions available for retrofit or

    original specification.• Hoods and bases may be specified (in bulk

    volumes) without fittings for customer cable entry selection.

    • Euro standard gland seal also available.

    Standard Strain Relief Fitting

    Euro Gland Seal

    Optional Strain ReliefTrumpet Gland

    Standard NPT Conduit Adapters• Euro Pg to NPT thread adapters (Pg male to

    NPT female).• Standard on all Pos-E-Kon hoods and bases.• Available separately for MRO.• Sizes from Pg11 to 1/2 in. NPT through Pg48 to

    1-1/2 in. NPT.

    6-20.pdf 6 1/5/2012 2:45:32 PM1-76.pdf 11 1/6/2012 10:52:55 AM

  • Pos-E-Kon™

    Accessories

    12

    Electro-Magnetic Shielding Component Shielding Kits

    • EM shielding at critical sealing lines.• Hood/Base and Coupler Hood kits.• Special EM Hood-Base entry fittings

    also available (see page 71).

    Rectangular connectors

    Shie

    ld a

    bsor

    ptio

    n (d

    B)

    Frequency F (MHz)

    Panel Base Surface Mount BaseInserts/Series and Hood Kit or Coupler Hood Kit EM-Fitting

    A10, D15 EM650A10 EM656A10A16, D25 EM651A16 EM657A16B6, T6, DD24 EM646B6 EM652B6B10, T10, V3, DD42 EM647B10 EM653B10B16, T16, C6, V6, D40, DD72 EM648B16 EM654B16B24, T24, V10, V16, D64, DD108 EM649B24 EM655B24

    Bulkhead/Panel Pass-Through Adapters• For panel wiring access through panel base entry.• Clamshell “Split Type” design also available.• 3 or 4 entry (4 standard).• Base B16 or B24 sizes.• Grommets sold separately, see chart below.

    Adapter Hood and Panel Base

    Series No. Adapter Hood Panel Base

    B16, T16, C6, V6, D40, DD72 (3 hole) CA628B16 PB116B24, T24, V10, V16, D64, DD108 (4 hole) CA629B24 PB124

    Feed-thru Grommets

    Cable O.D. (mm) Cat. No. Cable O.D. (mm) Cat. No.

    3-4 BSG630 10-11 BCG6374-5 BSG631 11-12 BCG638

    Straight 5-6 BSG632 Split Type 12-13 BCG639Grommet 6-7 BSG633 Grommet 13-14 BCG640

    7-8 BSG634 14-15 BCG6418-9 BSG635 15-16 BCG6429-10 BSG636

    Blind Plug – BPG644

    AssemblyStructureExample

    seepage71

    Use T&B Ty-Rap® No. TYV523M cable tie tobind wire to open-faced grommet.

    6-20.pdf 7 1/5/2012 2:45:33 PM1-76.pdf 12 1/6/2012 10:52:55 AM

  • 13

    Pos-E-Kon™

    Accessories

    POS-E-KONTM

    Improvements for 2001Introducing: New Ergonomic thermoplastic levers for “B” series double lever housings B10-B24

    Benefits: Non-slip comfortable gripEasier locking and unlocking

    And: New Laser etched labeling for all metal housings and hot-stamped labeling on contact carrier inserts.

    Benefits: Permanent marking with all data combinedExternal marking vs. internal label

    Metallic levers will continue to be available for all double lever housings.

    (Minimum order requirements)

    New “E” type levers will be standard for double lever B10through B24 size housings. All single lever housings are

    constructed with metallic levers.

    Reference: Catalogue Number Conversion• Add “E” suffix for Ergonomic style levers for all B10, 16 and 24 double-lever housings.

    Example: PB116 (Metal levers) becomes PB116E (Thermoplastic levers)LH224 (Metal levers) becomes LH224E (Thermoplastic levers)

    Catalogue Numbers affected (New catalogue number construction shown in catalogue)

    B10 Series B16 Series B24 Series

    PB110 PB116 LH016 PB124 CH624BB010 BB016 LH016H BB024 CH724BB110 BB116 LH116H BB124 LH124BB610 BB616 LH216 LH224BB710 BB716 LH216H LH024CH810 CH616 LH324

    6-20.pdf 8 1/5/2012 2:45:33 PM1-76.pdf 13 1/6/2012 10:52:55 AM

  • Pos-E-Kon™

    Catalogue Number System

    14

    Double posts (front/back) forDouble Lever locking.(single side post/lever also)

    HoodsTH – Top Entry Hood w/NPT fittingSH – Side Entry Hood w/NPT fitting

    Male and Female Inserts-same installation to anyhood or base orientation

    MS – Male Screw Terminal Insert (shown)

    FS – Female Screw TerminalInsert (shown)– OR –

    MC – Male Crimp InsertFC – Female Crimp Insert >use MP –Male and FP –FemalePins

    Base TypesBB – Box Base Housing

    Surface Mount with NPTconduit Entry (1 or 2) fit-tings (standard)

    Locking • Single lever/Single post or Double lever/Double posts locking.• “Reversed Locking” (levers on hoods) available.• New E-series ergonomic thermoplastic handles for double lever B series (B10, B16, B24).• Single lever & other series use metal levers.

    PB – Panel Base HousingPanel face or bulkhead mountingwith rear wiring access

    CH – Coupler HoodInline PortableConnection

    Easy to use—Catalogue number construction pioneered by Thomas & Betts

    Wiring Entry optionsCord or Conduit Adapter fittingsRibbon cable & Euro cable entry Housings without fittingsCustom assemblies

    Male and FemaleTerminal Block Wiring AdaptersMS or FSxxxWAR/WAL(right/left ground) optionsfor Panel Base installations.

    6-20.pdf 9 1/5/2012 2:45:34 PM1-76.pdf 14 1/6/2012 10:52:55 AM

  • 15

    Pos-E-Kon™

    Series Locator

    POS-E-KONTM

    A Series: Small, Compact Size 3, 4, 10, 16, 32 16Screw Terminal or Crimp Contacts

    B Series: Standard Size 6, 10, 16, 24, 32, 48 18Screw Terminal or Crimp Contacts

    C Series: High Current 6 or 12 22Screw Terminal

    D Series: Hi-Density 7, 8, 15, 25, 40, 24Crimp Contacts or 50, 64, 80, 128Fiber Optic Contacts

    DD Series: Very Hi-Density 24, 42, 72, 108, 144, 216 28Crimp Contacts orFiber Optic Contacts

    K Series: Combo, 16A: 8 + 4 32Hi-Current/Std. Current 80A: 16 + 8Screw Terminals

    V Series: Control Circuit 3, 6, 10, 16, ) +2 34Contacts and B Style 20, 26, 32 Screw Terminals

    T Series: B Style 6, 10, 16, 24 38Hi-Temp 200°CScrew Terminals

    M Series: All Modular Several to 50A 40Crimp Contacts and 3, 5, 7 Piece Fiber Optic Contacts Insert holders

    Reference & Specs, Dimensions, 51Accessories Components and

    Fiber Optics

    10A: 3, 416A: All other

    16A

    35A

    10A

    10A

    16A

    16A

    (Various)

    16A/80A

    Series Features Contacts + G Page

    6-20.pdf 10 1/5/2012 2:45:36 PM1-76.pdf 15 1/6/2012 10:52:55 AM

  • Pos-E-Kon™

    A Series 10 and 16 Amps 600 VAC

    16

    Crimp Tool Contacts Selection

    Crimp Terminal Inserts 10 + G 16 + G 32 + G

    Male InsertMC410A MC416A

    MC416A

    (Order contacts below) MC432A

    Female InsertFC310A FC316A

    FC316A(Order contacts below) FC332A

    Crimp Contacts Wire AWG (mm2) Identification

    20 AWG (0.5 mm2) No Groove

    18 AWG (0.75-1 mm2) 1 Groove

    16 AWG (1.5 mm2) 2 Grooves

    14 AWG (2.5 mm2) 3 Grooves

    12 AWG (4.0 mm2) No Groove

    3 or 4 Contacts + Ground: 10A10, 16 & 32 Contacts + Ground: 16A

    Install toMatching Series

    Hood/Base

    WT611TB

    DIN Rail Adapter Mount Frames 10 + G 16 + G

    150mm long, with base for AMF115 AMF125snapping onto DIN rail

    Adapter Mount Frames allow “open”wiring inside closed panel enclosure.They also allow Inserts to be assem-bled as a separable Terminal Blockdevice.

    3 or 4 (600V) 10 16 32

    For all Inserts

    Screw Terminal Inserts 3 or 4 + G 10 + G 16 + G 32 + G

    Male – Pins MS203A or MS216A

    20-14 AWG (0.5-2.5 mm2)MS204A MS210A MS216A +

    (16 AWG max) MS232A

    Female – Sleeves FS103A or FS116A

    20-14 AWG (0.5-2.5 mm2)FS104A FS110A FS116A +

    (16 AWG max) FS132A

    Female Male

    FP2000 MP2000

    FP1800 MP1800

    FP1600 MP1600

    FP1400 MP1400

    FP1200 MP1200

    For all Crimp Terminal “A” Inserts

    Use small blade screwdriverto push in wire entry tab foreasy contact removal.

    Groove

    +

    +

    6-20.pdf 11 1/5/2012 2:45:36 PM1-76.pdf 16 1/6/2012 10:52:55 AM

  • 17

    Pos-E-Kon™

    A Series 10 and 16 Amps 600 VAC

    POS-E-KONTM

    Top Entry

    Box Base (no Cover)

    Lever Locking TypeHousing

    Hoods – Standard Mount

    1 X 3/8" SH603A(P)s1 X 1/2" SH610A* SH616A*1 X 3/4" SH710A** SH716A** SH032A1 X 1" SH132A

    1 X 3/8" TH803A(P)s1 X 1/2" TH810A* TH816A*1 X 3/4" TH910A** TH916A** TH232A1 X 1" TH332A

    Side Entry

    Plastic body – “A” 3-16 Series standard Hoods include Gaskets: Bases and Special Hoods do not.

    Top Entry

    LH032ALH132A

    LH232ALH332A

    PB232A

    BB232ABB232A100

    BB332ABB332A100

    3 or 4 (600V) 10 16 32

    Lever Hoods mate to Post Bases ONLY.

    Number of Contacts + Ground Connection

    BASE

    TO

    HOOD

    HOOD

    TO

    COUPLER

    COUPLER

    HOOD

    TO

    BASE

    HOODS

    HOODS

    BASES

    BASE

    Post Bases accept Lever Hoods ONLY.Bases – with Access CoverPanel Base+

    Posts w/Cover

    1 X 3/4"Box Base+ 1 X 1"

    Posts w/Cover 2 X 3/4"2 X 1"

    Lever Hoods – Rev. Lock

    Side Entry 1 X 3/4"w/Lever(s) 1 X 1"

    Top Entry 1 X 3/4"w/Lever(s) 1 X 1"

    For In-line, Portable or Special Service ConnectionsCoupler Hoods – In-line

    1 X 3/8" CH803A(P)s1 X 1/2" CH810A CH816A

    Single Lever Double Lever

    *Available in Standard or LOW Profile “L” configurations (add suffix L).s (P) indicates glass-filled thermoplastic construction, light grey colour (add suffix P).

    (PB) indicates glass filled thermoplastic construction, black colour (add suffix PB). Minimum quantity. Purchase may be required.

    Reverse Locking

    NPTBases – Standard Mount Entry Single Single Single Double

    Panel Base PB303A(P)s PB310A PB316A PB132A

    w/Cover PB403A PB410A PB416A

    Angled PB503A(P)sno Cover

    1 X 3/8" BB403A(P)s1 X 1/2" BB410A BB416A1 X 3/4" BB032A1 X 1" BB832A2 X 1/2" BB510A BB516A2 X 3/4" BB132A2 X 1" BB132A100

    Box Base 1 X 1/2" BB610A BB616Aw/Cover 2 X 1/2 BB710A BB716A

    Coupler Hoods mate to Standard Hoods ONLY.

    17-E.pdf 1 2/2/2012 10:08:21 AM

  • Pos-E-Kon™

    B Series 16 Amps 600 VAC

    18

    Crimp Tool

    Crimp Terminal Inserts 6 + G 10 + G 16 + G

    Male Insert MC406B MC410B MC416B(Order contacts below)

    Female Insert FC306B FC310B FC316B(Order contacts below)

    For all Crimp Terminal “B” Inserts

    Screw Terminal Inserts 6 + G 10 + G 16 + G

    Male – PinsMS206B MS210B MS216B

    20-14 AWG (0.5-2.5 mm2)

    Female – SleevesFS106B FS110B FS116B

    20-14 AWG (0.5-2.5 mm2)

    Crimp Contacts Wire AWG (mm2) Identification Female Male

    20 AWG (0.5 mm2) No Groove FP2000 MP2000

    18 AWG (0.75-1 mm2) 1 Groove FP1800 MP1800

    16 AWG (1.5 mm2) 2 Grooves FP1600 MP1600

    14 AWG (2.5 mm2) 3 Grooves FP1400 MP1400

    12 AWG (4.0 mm2) No Groove FP1200 MP1200

    DIN Rail Adapter Mount Frames 6 + G 10 + G 16 + G

    125 mm long, with baseAMF006 AMF010 AMF016

    for snapping onto DIN rail

    150 mm long, with baseAMF106 AMF110 AMF116

    for snapping onto DIN rail

    150 mm long, with baseAMF112 – –

    for TWO inserts

    6, 10, 16, 24, 32, 48 Contacts + Ground

    Install toMatching Series

    Hood/Base

    6 10 16 6 10 16 6 10 16

    Adapter Mount Frames allow “open” wiringinside closed panel enclosure. They alsoallow Inserts to be assembled as a separableTerminal Block device.

    Accepts any Terminal Insert to same series.

    Screw Terminal Wiring Adapter Blocks 6 + G 10 + G 16 + G

    Male Insert, Ground L.MS206WAL MS210WAL MS216WAL

    20-14 AWG (0.5-2.5 mm2)

    Male Insert, Ground R.MS206WAR MS210WAR MS216WAR

    20-14 AWG (0.5-2.5 mm2)

    Female Insert, Ground L.FS106WAL FS110WAL FS116WAL

    20-14 AWG (0.5-2.5 mm2)

    Female Insert, Ground R.FS106WAR FS110WAR FS116WAR

    20-14 AWG (0.5-2.5 mm2)

    Foot Element mounting FE807TB FE807TB FE807TBadapter for DIN rail 2 needed 2 needed 2 needed

    Contacts Selection

    Accessories Catalogue No.

    Label Insert Clip WAM-1Strip blank WAM1B

    Strip Nos. 1-64 WAM1N64Strip Letters A - Z WAM1AZ

    Wiring Adapter Insert for use with PanelBases; allows single access direction

    panel-build wiring and easy terminal ID for service and testing.

    For all Inserts

    WT611TB

    Use small blade screwdriver to push inwire entry tab for easy contact removal.

    Groove

    6-20.pdf 13 1/5/2012 2:45:39 PM1-76.pdf 18 1/6/2012 10:52:55 AM

  • 19

    Pos-E-Kon™

    B Series 16 Amps 600 VAC

    POS-E-KONTM

    Lever Locking Type

    For In-line, Portable or Special Service Connections

    LH010ELH010EH075 LH016E*LH010EH100 LH116EH

    LH210ELH210EH075 LH216E*LH210EH100 LH316EH

    PB210 n PB216 n

    BB210 n

    BB210H075 n BB216* n

    BB210H100 n BB216H100 n

    BB310 n

    BB310H075 n BB316* n

    BB310H100 n BB316H100 n

    Post Bases accept Lever Hoods ONLY.

    BASE B

    ASE

    TO

    HOOD

    HOOD

    TO

    COUPLER

    COUPLER

    Box Base( no Cover )

    Side Entry

    Top Entry

    Top Entry

    Side Entryw/Lever(s)

    Top Entryw/Lever(s)

    Box + Postsw/Cover

    Box Basew/Cover

    *Available in Standard or HIGH Profile “H” configurations (add suffix H).n Add “M” final suffix for metal cover option.u Both HIGH (H) and LOW (L) profile also available (add suffix H or L).

    Lever Hoods mate to Post Bases ONLY.

    HOOD

    TO

    BASE

    HOODS

    HOODS

    BASES

    6 10 16 Number of Contacts + Ground Connection

    Bases – with Access Cover

    Panel + Postsw/Cover

    1 X 1/2"1 X 3/4"1 X 1"2 X 1/2"2 X 3/4"2 X 1"

    Lever Hoods – Reversed Lock1 X 1/2"1 X 3/4"1 X 1"

    1 X 1/2"1 X 3/4"1 X 1"

    Single Lever Double Lever NPTBases – Standard Mount Entry Single Single Double Single Double

    Panel Base PB306 n PB310 n PB110E PB316 n PB116E

    w/Cover PB406 n PB410 n PB416 n

    1 X 1/2" BB406 BB410 BB010E1 X 3/4" BB406H075 BB410H075 BB010EH075 BB416* BB016E*1 X 1" BB406H100 BB410H100 BB010EH100 BB416H100 BB016EH1002 X 1/2" BB506 BB510 BB110E2 X 3/4" BB506H075 BB510H075 BB110EH075 BB516* BB116E*2 X 1" BB506H100 BB510H100 BB110EH100 BB516H100 BB116EH100

    1 X 1/2" BB606 n BB610 n

    1 X 3/4" BB606H075 n BB610H075 n BB616* n

    1 X 1" BB606H100 n BB610H100 n BB616H100 n

    2 X 1/2" BB706 n BB710 n

    2 X 3/4" BB706H075 n BB710H075 n BB716* n

    2 X 1" BB706H100 n BB710H100 n BB716H100 n

    Hoods – Standard Mount1 X 1/2" SH606 SH610 SH0101 X 3/4" SH606H075 SH610H075 SH010H075 SH616u SH016u1 X 1" SH606H100 SH610H100 SH010H100 SH716u SH116Hu

    1 X 1/2" TH806 TH810 TH2101 X 3/4" TH806H075 TH810H075 TH210H075 TH816u TH216u1 X 1" TH806H100 TH810H100 TH210H100 TH816H100 TH316H

    Coupler Hoods – In-line Coupler Hoods mate to Standard Hoods ONLY.

    1 X 1/2" CH806 CH810 CH610E1 X 3/4" CH806H075 CH810H075 CH610EH075 CH816H CH616EH1 X 1" CH806H100 CH810H100 CH610EH100 CH916H CH716EH

    Reverse Locking

    Housing

    6-20.pdf 14 1/5/2012 2:45:39 PM1-76.pdf 19 1/6/2012 10:52:55 AM

  • Pos-E-Kon™

    B Series 16 Amps 600 VAC

    20

    Crimp Tool Contacts SelectionCrimp Contacts Wire Gauge AWG (mm2) Identification Female Male

    20 AWG (0.5 mm2) No Groove FP2000 MP2000

    18 AWG (0.75-1 mm2) 1 Groove FP1800 MP1800

    16 AWG (1.5 mm2) 2 Grooves FP1600 MP1600

    14 AWG (2.5 mm2) 3 Grooves FP1400 MP1400

    12 AWG (4.0 mm2) No Groove FP1200 MP1200

    Install toMatching Series

    Hood/Base

    Adapter Mount Frames allow “open”wiring inside closed panel enclosure. They also allow Inserts to be assembledas a separable Terminal Block device.

    For all Crimp Terminal “B” Inserts

    DIN Rail Adapter Mount Frames 24 + G

    150 mm long, with baseAMF124

    for snapping onto 33 mm rail

    Accessories Catalogue No.

    Label Insert Clip WAM-1Strip blank WAM1B

    Strip Nos. 1-64 WAM1N64Strip Letters A - Z WAM1AZ

    Wiring Adapter Insert for use with PanelBases; allows single access direction

    panel-build wiring and easy terminal IDfor service and testing.

    24 32 48 6, 10, 16, 24, 32, 48 Contacts + Ground

    Screw Terminal Inserts 24 + G 32 + G 48 + G

    Male PinsMS224B

    MS216B (1-16) MS224B (1-24)

    20-14 AWG (0.5-2.5 mm2) MS232B (17-32) MS248B (25-48)

    Female SleevesFS124B

    FS116B (1-16) FS124B (1-24)

    20-14 AWG (0.5-2.5 mm2) FS132B (17-32) FS148B (25-48)

    Screw Terminal Wiring Adapter Blocks 24 + G

    Male Insert, Ground L.MS224WAL

    20-14 AWG (0.5-2.5 mm2)

    Male Insert, Ground R.MS224WAR

    20-14 AWG (0.5-2.5 mm2)

    Female Insert, Ground L.FS124WAL

    20-14 AWG (0.5-2.5 mm2)

    Female Insert, Ground R.FS124WAR

    20-14 AWG (0.5-2.5 mm2)

    Foot Element mountingFE807TB

    adapter for DIN rail

    Crimp Terminal Inserts 24 + G 32 + G 48 + G

    Male InsertMC424B

    (1-16) MC416B (1-24) MC424B(Order contacts below) (17-32) MC432B (25-48) MC448B

    Female InsertFC324B

    (1-16) FC316B (1-24) FC324B(Order contacts below) (17-32) FC332B (25-48) FC348B

    For all Inserts

    WT611TB

    Use small blade screwdriver to push wirein entry tab for easy contact removal.

    Groove

    + +

    + +

    6-20.pdf 15 1/5/2012 2:45:40 PM1-76.pdf 20 1/6/2012 10:52:55 AM

  • 21

    Pos-E-Kon™

    B Series 16 Amps 600 VAC

    POS-E-KONTM

    Hoods – Standard Mount1 X 3/4" **SH624** **SH024** SH0321 X 1" **SH724** **SH124** SH132 SH6481 X 1-1/4" SH132-125 SH748

    1 X 3/4" **TH824** **TH224** TH2321 X 1" **TH924** **TH324** TH332 TH8481 X 1-1/4" TH332-125 TH948

    Ribbon CBL TH624RC‡ TH424RC‡

    Coupler Hoods – In-line Service1 X 3/4" CH824 CH624E CH6321 X 1" CH924 CH724E CH732

    Ribbon CBL CH824RC‡ CH724ERC‡

    LH024ELH124E

    LH224ELH324E

    PB224 n

    BB224*n

    BB224H100BB324*n

    BB324H100

    Post Bases accept Lever Hoods ONLY.

    **Available in Standard or HIGH Profile “H” configurations (add suffix H).**Available in Standard or LOW Profile “L” configurations (add suffix L).n Add “M” final suffix for metal cover option.‡ See page 71 for ribbon cable kits.

    Lever Locking TypeHousing

    Side Entry

    Top Entry

    For In-line, Portable or Special Service Connections

    24 32 48

    Lever Hoods mate to Post Bases ONLY.

    Number of Contacts + Ground Connection

    Top Entry

    BASE B

    ASE

    TO

    HOOD

    HOOD

    TO

    COUPLER

    COUPLER

    HOOD

    TO

    BASE

    HOODS

    HOODS

    BASES

    Bases – with Access Cover

    Panel Basew/Posts + Cover

    1 X 3/4"Box Base 1 X 1"

    w/Posts + Cover 2 X 3/4"2 X 1"

    Lever Hoods – Rev. Lock

    Side Entry 1 X 3/4"w /Lever(s) 1 X 1"

    Top Entry 1 X 3/4"w/Lever(s) 1 X 1"

    Single Lever Double Lever

    Reverse Locking

    NPTBases – Standard Mount Entry Single Double Double Single

    Panel Base PB324 n PB124E PB132 PB348

    w/Cover PB424 n PB448

    1 X 3/4" BB424* BB024E*Box Base 1 X 1" BB424H100 BB024EH100 BB032 BB448

    ( no Cover ) 2 X 3/4" BB524* BB124E*2 X 1" BB524H100 BB124EH100 BB132 BB548

    1 X 3/4" BB624* n

    Box Base 1 X 1" BB624H100 n BB648w/Cover 2 X 3/4" BB724* n

    2 X 1" BB724H100 n BB748

    Coupler Hoods mate to Standard Hoods ONLY.

    21-30.pdf 1 1/5/2012 2:45:52 PM1-76.pdf 21 1/6/2012 10:52:55 AM

  • 22

    Pos-E-Kon™

    Screw Terminal Contact Carrier Inserts 6 + G 12 + G

    Male – PinsMS206C

    MS206C (1-6)

    20-10 AWG (0.5-2.5 mm2) MS212C (7-12)

    Female – SleevesFS106C

    FS106C (1-6)

    20-10 AWG (0.5-2.5 mm2) FS112C (7-12)

    6 or 12 Contacts + Ground

    Install toMatching Series

    Hood/Base

    6 12

    C Series 35 Amps 600 VAC

    +

    +

    21-30.pdf 2 1/5/2012 2:45:52 PM1-76.pdf 22 1/6/2012 10:52:55 AM

  • 23

    Pos-E-Kon™

    C Series 35 Amps 600 VAC

    POS-E-KONTM

    PB216 n

    BB216* n

    BB216H100 n

    BB316* n

    BB316H100 n

    NPTBases – Standard Mount Entry Single Double Double

    Panel Base PB316 PB116E PB132

    w/Cover PB416

    1 X 3/4" BB416* BB016E*Box Base 1 X 1" BB416H100 BB016EH100 BB032

    ( no Cover ) 2 X 3/4" BB516* BB116E*2 X 1" BB516H100 BB116EH100 BB132

    1 X 3/4" BB616* n

    Box Base 1 X 1" BB616H100 n

    w/Cover 2 X 3/4" BB716* n

    2 X 1" BB716H100 n

    Hoods – Standard Mount

    1 X 3/4" SH616u SH016u SH0321 X 1" SH716 SH116H SH1321 X 1-1/4" SH132-125

    1 X 3/4" TH816u TH216u TH2321 X 1" TH816H100 TH316H TH3321 X 1-1/4" TH332-125

    LH016E*LH116EH

    LH216E*LH316EH*

    Post Bases accept Lever Hoods ONLY.

    *Available in Standard or HIGH Profile “H” configurations (add suffix H).**Available in Standard or LOW Profile “L” configurations (add suffix L).n Add “M” final suffix for metal cover option.u Both HIGH (H) and LOW (L) profile also available (add suffix H or L).

    Single Lever Double Lever Lever Locking TypeHousing

    Side Entry

    Top Entry

    For In-line, Portable or Special Service Connections

    Top Entry

    6 12

    Lever Hoods mate to Post Bases ONLY.

    Number of Contacts + Ground Connection

    BASE B

    ASE

    TO

    HOOD

    HOOD

    TO

    COUPLER

    COUPLER

    HOOD

    TO

    BASE

    HOODS

    HOODS

    BASES

    Bases – with Access Cover

    Panel + Postsw/Cover

    1 X 3/4"Box + Posts 1 X 1"

    w/Cover 2 X 3/4"2 X 1"

    Lever Hoods – Rev. Lock

    Side Entry 1 X 3/4"w/Lever(s) 1 X 1"

    Top Entry 1 X 3/4"w/Lever(s) 1 X 1"

    Coupler Hoods – In-line Coupler Hoods mate to Standard Hoods ONLY.

    1 X 3/4" CH816H CH616EH CH6321 X 1" CH916H CH716EH CH732

    Reverse Locking

    21-30.pdf 3 1/5/2012 2:45:52 PM1-76.pdf 23 1/6/2012 10:52:55 AM

  • Pos-E-Kon™

    D Series 10 Amps 600 VAC

    24

    Extraction Tool

    Crimp Tool

    7 or 8, 15, 25 & 40 Contacts + Ground

    Install toMatching Series

    Hood/Base

    Crimp Terminal Inserts 7 or 8 + G 15 + G 25 + G 40 + G

    Male Insert MC407D orMC415D MC425D MC440D

    (Order contacts below) MC408D

    Female Insert FC307D orFC315D FC325D FC340D

    (Order contacts below) FC308D

    Adapter Mount Frames allow “open”wiring inside closed panel enclosure.They also allow Inserts to be assem-bled as a separable Terminal Blockdevice.

    DIN Rail Adapter Mount Frames 15 + G 25 + G 40 + G

    125mm long, with base AMF115 AMF125 AMF016for snapping onto DIN rail

    150mm long, with base AMF116

    for snapping onto DIN rail

    7 or 8 15 25 40

    Screw Terminal Wiring Adapter Block 40 + G

    Male Insert, Ground L.MS440WAL

    26 - 16 AWG (0.2-1.5mm2)

    Female Insert, Ground L.FS340WAL

    26 - 16 AWG (0.2-1.5mm2)

    Foot Element mounting FE807TB2X per adapter for DIN rail (2x needed)

    Contacts Sold Separately

    Contacts Selection Chart

    Crimp Contacts Wire Gauge AWG (mm2) Identification Female Male

    22+ AWG (0.14-0.37 mm2) 1 FP22SD MP22SD

    20 AWG (0.5 mm2) 2 FP20SD MP20SD

    18 AWG (0.75-1 mm2) 3 FP18SD MP18SD

    16 AWG (1.5 mm2) 4 FP16SD MP16SD

    14 AWG (2.5 mm2) 5 FP14SD MP14SD

    See page 72 for POF installationand tools info.

    Fiber Optic Contacts

    Crimp Contacts Wire Gauge AWG (mm2) Female Male

    Fiber Optic Cable, Size 1 mm FPF520 MPF530

    WT80

    Accessories Catalogue No.

    Label Insert Clip WAM-1Strip blank WAM1B

    Strip Nos. 1-64 WAM1N64Strip Letters A - Z WAM1AZ

    Wiring Adapter Insert for use with Panel Bases; allows single

    access direction panel-build wiring and easy terminal ID for

    service and testing.

    For Crimp Terminal “D” Inserts

    For all Inserts

    RT614

    I.D.

    21-30.pdf 4 1/5/2012 2:45:53 PM1-76.pdf 24 1/6/2012 10:52:55 AM

  • 25

    Pos-E-Kon™

    D Series 10 Amps 600 VAC

    POS-E-KONTM

    PB216 n

    BB216* n

    BB216H100 n

    BB316* n

    BB316H100 n

    Lever Hoods mate to Post Bases ONLY.

    Lever Locking TypeNPTBases – Standard Mount Entry Single Single Single Single Double

    Panel Base PB303A(P)s PB310A PB316 PB116E

    w/Cover PB403A PB410A PB316A PB416

    Angled, PB503A(P)s PB416A( no Cover )1 X 3/8" BB403A(P)s1 X 1/2" BB410A BB416A2 X 1/2" BB510A BB516A1 X 3/4" BB416* BB016E*1 X 1" BB416H100 BB016EH1002 X 3/4" BB516* BB116E*2 X 1" BB516H100 BB116EH1001 X 1/2" BB610A BB616A2 X 1/2" BB710A BB716A1 X 3/4" BB616* n1 X 1" BB616H100 n2 X 3/4" BB716* n2 X 1" BB716H100 n

    Hoods – Standard Mount1 X 3/8" SH603A(P)s1 X 1/2" SH610A SH616A1 X 3/4" SH710A SH716A SH616u SH016u1 X 1" SH716u SH116H

    1 X 3/8" TH803A(P)s1 X 1/2" TH810A TH816A1 X 3/4" TH910A TH916A TH816u TH216u1 X 1" TH816H100 TH316H

    For In-line, Portable or Special Service Connections

    Coupler Hoods – In-line Coupler Hoods mate to Standard Hoods ONLY.

    1 X 3/8" CH803A(P)s1 X 1/2" CH810A CH816A1 X 3/4" CH816H CH616EH1 X 1" CH916H CH716EH

    Box Base( no Cover )

    Side Entry

    Top Entry

    Top Entry

    Box Basew/Cover

    “A” 7-25 Series standard Hoods include Gaskets: Bases and Special Hoods do not.

    Side Entryw/Lever(s)

    Top Entryw/Lever(s)

    7 or 8 15 25 40 Number of Contacts + Ground Connection

    BASE

    TO

    HOOD

    HOOD

    TO

    COUPLER

    COUPLER

    HOOD

    TO

    BASE

    HOODS

    HOODS

    BASES

    LH016E*LH116EH

    LH216E*LH316EH

    Lever Hoods – Reversed Lock1 X 1/2"1 X 3/4"1 X 1"

    1 X 1/2"1 X 3/4"1 X 1"

    TH816RC, TH216RC(Ribbon Cable)

    CH816RC, CH716ERC(Ribbon Cable)

    BASE

    Bases – with Access Cover

    Panel + Postsw/Cover

    1 X 3/4"Box + Posts 1 X 1"

    w/Cover 2 X 3/4"2 X 1"

    Post Bases accept Lever Hoods ONLY.

    **Available in Standard or HIGH Profile “H” configurations (add suffix H).**Available in Standard or LOW Profile “L” configurations (add suffix L).s (P) indicates glass-filled thermoplastic construction.n Add “M” final suffix for metal cover option.u Both HIGH (H) and LOW (L) profile also available (add suffix H or L).

    Reverse Locking

    HousingSingle Lever Double Lever

    21-30.pdf 5 1/5/2012 2:45:53 PM1-76.pdf 25 1/6/2012 10:52:56 AM

  • Pos-E-Kon™

    D Series 10 Amps 600 VAC

    26

    50 64 80 12850, 64, 80 & 128 Contacts + Ground

    Install toMatching Series

    Hood/Base

    Adapter Mount Frames allow“open” wiring inside closedpanel enclosure. They also allowInserts to be assembled as a sep-arable Terminal Block device.

    DIN Rail Adapter Mount Frames 64 + G

    AMF124150mm long, withbase for snapping onto

    DIN rail

    Screw Terminal Wiring Adapter Block 64 + G

    Male Insert, Ground L.MS464WAL

    26 - 16 AWG (0.2-1.5mm2)

    Female Insert, Ground L.FS364WAL

    26 - 16 AWG (0.2-1.5mm2)

    Foot Element mounting FE807TB2X per adapter for DIN rail (2x needed)

    Crimp Terminal Inserts 50 + G 64 + G 80 + G 128 + G

    Male Insert MC425D (2x) MC464D MC440D (2x) MC464D (2x)(Order contacts below)

    Female InsertFC325D (2x) FC364D FC340D (2x) FC364D (2x)

    (Order contacts below)

    Contacts Selection Chart

    Crimp Contacts Wire Gauge AWG (mm2) Identification Female Male

    22+ AWG (0.14-0.37 mm2) 1 FP22SD MP22SD

    20 AWG (0.5 mm2) 2 FP20SD MP20SD

    18 AWG (0.75-1 mm2) 3 FP18SD MP18SD

    16 AWG (1.5 mm2) 4 FP16SD MP16SD

    14 AWG (2.5 mm2) 5 FP14SD MP14SD

    Accessories Catalogue No.

    Label Inserts WAM-2Strip Blank WAM2B

    Strip Nos. 1-64 W2N64Strip Letters A - Z WAM2AZ

    Wiring Adapter Insert for use with Panel Bases; allows single

    access direction panel-build wiring and easy terminal ID

    for service and testing.

    See page 72 for POF installation and tools info.

    Fiber Optic Contacts

    Crimp Contacts Wire Gauge AWG (mm2) Female Male

    Fiber Optic Cable, Size 1 mm FPF520 MPF530

    For Crimp Terminal “D” Inserts

    WT80

    RT614

    Extraction ToolI.D.

    Crimp Tool

    21-30.pdf 6 1/5/2012 2:45:53 PM1-76.pdf 26 1/6/2012 10:52:56 AM

  • 27

    Pos-E-Kon™

    D Series 10 Amps 600 VAC

    POS-E-KONTM

    50 64 80 128

    Lever Locking Type

    Box Basew/Cover

    Side Entry

    Top Entry

    NPTBases – Standard Mount Entry Double Single Double Double Single

    Panel Base PB132A PB324 PB124E PB132 PB348

    w/Cover PB403A PB424

    1 X 3/4" BB032A BB424* BB024E*1 X 1" BB832A BB424H100 BB024EH100 BB032 BB4482 X 3/4" BB132A BB524* BB124E*2 X 1" BB132A100 BB524H100 BB124EH100 BB132 BB548

    1 X 3/4" BB624* n

    1 X 1" BB624H100 n BB6482 X 3/4" BB724* n

    2 X 1" BB724H100 n BB748

    Number of Contacts + Ground Connections

    Box Base(no Cover)

    For In-line, Portable or Special Service Connections

    Coupler Hoods – In-line

    1 X 3/4" CH824 CH624E CH6321 X 1" CH924 CH724E CH732

    Ribbon CBL CH824RC‡ CH724ERC‡Top Entry

    LH024ELH124E

    LH224ELH324E

    Coupler Hoods mate to Standard Hoods ONLY.

    Lever Hoods mate to Post Bases ONLY.

    PB224 n

    BB224*n

    BB224H100BB324*n

    BB324H100

    Panel + Postsw/Cover

    Box + Postsw/Cover

    Post Bases accept Lever Hoods ONLY.

    **Available in Standard or HIGH Profile “H” configurations (add suffix H).**Available in Standard or LOW Profile “L” configurations (add suffix L).n Add “M” final suffix for metal cover option.‡ See page 71 for ribbon cable kits.

    Hoods – Standard Mount1 X 3/4" SH032A SH624** SH024** SH0321 X 1" SH132A SH724** SH124** SH132 SH6481 X 1-1/4" SH748

    1 X 3/4" TH232A TH824** TH224** TH2321 X 1" TH332A TH924** TH324** TH332 TH8481 X 1-1/4" TH948

    Ribbon CBL TH624RC‡ TH424RC‡

    BASE

    BASE

    TO

    HOOD

    HOOD

    TO

    COUPLER

    COUPLER

    HOOD

    TO

    BASE

    HOODS

    HOODS

    BASES

    Top Entryw/Lever(s)

    Side Entryw/Lever(s)

    Lever Hoods – Reversed Lock

    1 X 3/4" LH032A1 X 1" LH132A

    1 X 3/4" LH232A1 X 1" LH332A

    Bases – with Access Cover

    PB232A

    1 X 3/4" BB232A1 X 1" BB232A1002 X 3/4" BB332A2 X 1" BB332A100

    Reverse Locking

    Housing

    Single Lever Double Lever

    21-30.pdf 7 1/5/2012 2:45:54 PM1-76.pdf 27 1/6/2012 10:52:56 AM

  • Pos-E-Kon™

    DD Series 10 Amps 600 VAC

    28

    Install toMatching Series

    Hood/Base

    Crimp Terminal Inserts 24 + G 42 + G 72 + G

    Male InsertMC224DD MC242DD MC272DD

    (Order contacts below)

    Female InsertFC124DD FC142DD FC172DD

    (Order contacts below)

    24 42 72 24, 42, 72 Contacts + Ground

    Contacts Selection Chart

    Crimp Contacts Wire Gauge AWG (mm2) Identification Female Male

    22+ AWG (0.14-0.37 mm2) 1 FP22SD MP22SD

    20 AWG (0.5 mm2) 2 FP20SD MP20SD

    18 AWG (0.75-1 mm2) 3 FP18SD MP18SD

    16 AWG (1.5 mm2) 4 FP16SD MP16SD

    14 AWG (2.5 mm2) 5 FP14SD MP14SD

    Adapter Mount Frames allow “open”wiring inside closed panel enclosure.They also allow Inserts to be assembledas a separable Terminal Block device.

    DIN Rail Adapter Mount Frames 24 + G 42 + G 72 + G

    150 mm long, with baseAMF106 AMF110 AMF116

    for snapping onto DIN rail

    125 mm long style AMF006 AMF010 AMF016

    150 mm long; doubleAMF112

    for Dual Inserts Mounting

    See page 72 for POF installation and tools info.

    Fiber Optic Contacts

    Crimp Contacts Wire Gauge AWG (mm2) Female Male

    Fiber Optic Cable, Size 1 mm FPF520 MPF530

    For all Inserts

    WT80

    Crimp Tool

    RT614

    Extraction ToolI.D.

    For all Crimp Terminal “DD” Inserts

    21-30.pdf 8 1/5/2012 2:45:54 PM1-76.pdf 28 1/6/2012 10:52:56 AM

  • 29

    Pos-E-Kon™

    DD Series 10 Amps 600 VAC

    POS-E-KONTM

    Box Basew/Cover

    Box Base(no Cover)

    24 42 72

    Lever Locking Type

    Side Entry

    Top Entry

    Number of Contacts + Ground Connection

    Housing

    Hoods – Standard Mount1 X 1/2" SH606 SH610 SH0101 X 3/4" SH606H075 SH610H075 SH010H075 SH616u SH016u1 X 1" SH606H100 SH610H100 SH010H100 SH716u SH116H

    1 X 1/2" TH806 TH810 TH2101 X 3/4" TH806H075 TH810H075 TH210H075 TH816u TH216u1 X 1" TH806H100 TH810H100 TH210H100 TH816H100 TH316H

    Ribbon CBL TH816RC‡ TH216RC‡

    For In-line, Portable or Special Service Connections

    Top Entryw/Lever(s)

    * Available in Standard or HIGH Profile “H” configurations (add suffix H).n Add “M” final suffix for metal cover option.u Both HIGH (H) and LOW (L) profile also available (add suffix H or L).‡ See page 71 for ribbon cable kits.

    Coupler Hoods – In-line Coupler Hoods mate to Standard Hoods ONLY.

    1 X 1/2" CH806 CH810 CH610E1 X 3/4" CH806H075 CH810H075 CH610EH075 CH816H CH616EH1 X 1" CH806H100 CH810H100 CH610EH100 CH916H CH716EH

    Ribbon CBL CH816RC‡ CH616ERC‡

    BASE

    BASE

    TO

    HOOD

    HOOD

    TO

    COUPLER

    COUPLER

    HOODS

    NPTBases – Standard Mount Entry Single Single Double Single Double

    Panel Base PB306 n PB310 n PB110E PB316 PB116E

    w/Cover PB406 n PB410 n PB416

    1 X 1/2" BB406 BB410 BB010E1 X 3/4" BB406H075 BB410H075 BB010EH075 BB416* BB016E*1 X 1" BB406H100 BB410H100 BB010EH100 BB416H100 BB016EH1002 X 1/2" BB506 BB510 BB110E2 X 3/4" BB506H075 BB510H075 BB110EH075 BB516* BB116E*2 X 1" BB506H100 BB510H100 BB110EH100 BB516H100 BB116EH100

    1 X 1/2" BB606 n BB610 n

    1 X 3/4" BB606H075 n BB610H075 n BB616* n

    1 X 1" BB606H100 n BB610H100 n BB616H100 n

    2 X 1/2" BB706 n BB710 n

    2 X 3/4" BB706H075 n BB710H075 n BB716* n

    2 X 1" BB706H100 n BB710H100 n BB716H100 n

    LH010ELH010EH075 LH016E*LH010EH100 LH116EH

    LH210ELH210EH075 LH216E*LH210EH100 LH316EH

    PB210 n PB216 n

    BB210 n

    BB210H075 n BB216* n

    BB210H100 n BB216H100 n

    BB310n

    BB310H075 n BB316* n

    BB310H100 n BB316H100 n

    Post Bases accept Lever Hoods ONLY.

    Side Entryw/Lever(s)

    Top Entryw/Lever(s)

    Box + Postsw/Cover

    Lever Hoods mate to Post Bases ONLY.

    HOOD

    TO

    BASE

    HOODS

    BASES

    Bases – with Access Cover

    Panel + Postsw/Cover

    1 X 1/2"1 X 3/4"1 X 1"2 X 1/2"2 X 3/4"2 X 1"

    Lever Hoods – Reversed Lock1 X 1/2"1 X 3/4"1 X 1"

    1 X 1/2"1 X 3/4"1 X 1"

    Reverse Locking

    Single Lever Double Lever

    21-30.pdf 9 1/5/2012 2:45:55 PM1-76.pdf 29 1/6/2012 10:52:56 AM

  • Pos-E-Kon™

    DD Series 10 Amps 600 VAC

    30

    Install toMatching Series

    Hood/Base

    Crimp Terminal Inserts 108 + G 144 + G 216 + G

    Male InsertMC208DD

    MC272DD+ MC208DD+(Order contacts below) MC244DD MC216DD

    Female InsertFC108DD

    FC172DD+ FC108DD+(Order contacts below) FC144DD FC116DD

    108 144 216 108, 144 & 216 Contacts + Ground

    Contacts Selection

    Crimp Contacts Wire Gauge AWG (mm2) Identification Female Male

    22+ AWG (0.14-0.37 mm2) 1 FP22SD MP22SD

    20 AWG (0.5 mm2) 2 FP20SD MP20SD

    18 AWG (0.75-1 mm2) 3 FP18SD MP18SD

    16 AWG (1.5 mm2) 4 FP16SD MP16SD

    14 AWG (2.5 mm2) 5 FP14SD MP14SD

    Adapter Mount Frames allow “open” wiringinside closed panel enclosure. They also allowInserts to be assembled as a separableTerminal Block device.

    See page 72 for POF installation and tools info.

    Fiber Optic Contacts

    Crimp Contacts Wire Gauge AWG (mm2) Female Male

    Fiber Optic Cable, Size 1 mm FPF520 MPF530

    For all Crimp Terminal “DD”Inserts

    For all Inserts

    DIN Rail Adapter Mount Frames 108 + G

    150 mm long, with baseAMF124

    for snapping onto DIN rail

    WT80

    Crimp Tool

    RT614

    Extraction ToolI.D.

    21-30.pdf 10 1/5/2012 2:45:55 PM1-76.pdf 30 1/6/2012 10:52:56 AM

  • 31

    Pos-E-Kon™

    DD Series 10 Amps 600 VAC

    POS-E-KONTM

    NPTBases – Standard Mount Entry Single Double Double Single

    Panel Base PB324 PB124E PB132 PB348

    w/Cover PB424 n PB448

    1 X 3/4" BB424* BB024E*Box Base 1 X 1" BB424H100 BB024EH100 BB032 BB448

    ( no Cover ) 2 X 3/4" BB524* BB124E*2 X 1" BB524H100 BB124EH100 BB132 BB548

    1 X 3/4" BB624* n

    Box Base 1 X 1" BB624H100 n BB648w/Cover 2 X 3/4" BB724* n

    2 X 1" BB724H100 n BB748

    Hoods – Standard Mount1 X 3/4" **SH624** *SH024** SH0321 X 1" SH724** SH124** SH132 SH6481 X 1-1/4" SH132-125 SH748

    1 X 3/4" **TH824** **TH224** TH2321 X 1" TH924 TH324 TH332 TH8481 X 1-1/4" TH332-125 TH948

    Ribbon CBL TH624RC‡ TH424RC‡

    Coupler Hoods – In-line Service Coupler Hoods mate to Standard Hoods ONLY.

    1 X 3/4" CH824 CH624E CH6321 X 1" CH924 CH724E CH732

    Ribbon CBL CH824RC‡ CH624ERC‡

    Lever Locking TypeHousing

    Side Entry

    Top Entry

    For In-line, Portable or Special Service Connections

    108 144 216

    Top Entry

    BASE

    BASE

    TO

    HOOD

    HOOD

    TO

    COUPLER

    COUPLER

    HOODS

    LH024ELH124E

    LH224ELH324E

    PB224 n

    BB224*n

    BB224H100BB324*n

    BB324H100

    Post Bases accept Lever Hoods ONLY.

    **Available in Standard or HIGH Profile “H” configurations (add suffix H).**Available in Standard or LOW Profile “L” configurations (add suffix L).n Add “M” final suffix for metal cover option.‡ See page 71 for ribbon cable kits.

    Lever Hoods mate to Post Bases ONLY.

    HOOD

    TO

    BASE

    HOODS

    BASES

    Bases – with Access Cover

    Panel Basew/Posts + Cover

    1 X 3/4"Box Base 1 X 1"

    w/Posts + Cover 2 X 3/4"2 X 1"

    Lever Hoods – Rev. Lock

    Side Entry 1 X 3/4"w /Lever(s) 1 X 1"

    Top Entry 1 X 3/4"w/Lever(s) 1 X 1"

    Reverse Locking

    Number of Contacts + Ground Connections

    Single Lever Double Lever

    31-40.pdf 1 1/5/2012 2:46:05 PM1-76.pdf 31 1/6/2012 10:52:56 AM

  • Pos-E-Kon™

    K Series 80 + 16 Amps 600 VAC

    32

    4 Contacts @ 80A + 8 Contacts @ 16A8 Contacts @ 80A + 16 Contacts @ 16A+ Ground

    Install toMatching Series

    Hood/Base

    Wiring Note: 6 AWG (16mm2) for 80A Contacts14 AWG (2.5mm2) for 16A Contacts

    4 @80A +8 @16A + G

    8 @80A +16 @16A + G

    Screw Terminal Contact Carrier Inserts 4 @80A+ 8 @80A+8 @216A+G 16 @16A+G

    Male – Pins MS212K MS212K (x2)

    Female – Sleeves FS112K FS112K (x2)

    Other Configurations

    Special order high amperage and/or combo configurations may beavailable. Contact your RegionalSales Office.

    31-40.pdf 2 1/5/2012 2:46:05 PM1-76.pdf 32 1/6/2012 10:52:56 AM

  • 33

    Pos-E-Kon™

    K Series 80 + 16 Amps 600 VAC

    POS-E-KONTM

    NPTBases – Standard Mount Entry Single Double Single

    Panel Base PB324 PB124E PB348

    w/Cover PB424

    1 X 3/4" BB424* BB024E*Box Base 1 X 1" BB424H100 BB024EH100 BB448

    ( no Cover ) 2 X 3/4" BB524* BB124E*2 X 1" BB524H100 BB124EH100 BB548

    1 X 3/4" BB624 n*Box Base 1 X 1" BB624H100 n BB648w/Cover 2 X 3/4" BB724 n*

    2 X 1" BB724H100 n BB748

    LH024ELH124E

    LH224ELH324E

    PB224 n

    BB224 n*BB324 n*

    Post Bases accept Lever Hoods ONLY.

    Lever Locking TypeHousing

    Side Entry

    Top Entry

    For In-line, Portable or Special Service Connections

    Coupler Hoods – In-line Coupler Hoods mate to Standard Hoods ONLY.

    1 X 3/4" CH824 CH624E1 X 1" CH924 CH724E

    Top Entry

    K-12 K-248 @16A + G 16 @16A, + G4 @80A + G 8 @80A + G

    Lever Hoods mate to Post Bases ONLY.

    Number of Contacts + Ground Connection

    Box Basew/Posts + Cover

    BASE

    BASE

    TO

    HOOD

    HOOD

    TO

    COUPLER

    COUPLER

    HOOD

    TO

    BASE

    HOODS

    HOODS

    BASES

    Bases – with Access Cover

    Panel Basew/Posts + Cover

    1 X 3/4"2 X 3/4"

    Lever Hoods – Rev. Lock

    Side Entry 1 X 3/4"w/Lever(s) 1 X 1"

    Top Entry 1 X 3/4"w/Lever(s) 1 X 1"

    Hoods – Standard Mount1 X 3/4" SH624** SH024**1 X 1" SH724** SH124** SH6481 X 1-1/4" SH748

    1 X 3/4" TH824** TH224**1 X 1" TH924** TH324** TH8481 X 1-1/4" TH948

    Reverse Locking

    **Available in Standard or HIGH Profile “H” configurations (add suffix H).**Available in Standard or LOW Profile “L” configurations (add suffix L).n Add “M” final suffix for metal cover option.

    Single Lever Double Lever

    31-40.pdf 3 1/5/2012 2:46:06 PM1-76.pdf 33 1/6/2012 10:52:56 AM

  • Pos-E-Kon™

    V Series 16 Amps 600 VAC

    34

    Crimp Tool

    3, 6, 10, 16, 20, 26 & 32 Contacts+ Control Contacts & Ground

    Install toMatching Series

    Hood/Base

    Screw Terminal Inserts 3 + G 6 + G+ 2 Control + 2 Control

    Male – PinsMS203V MS206V

    20-14 AWG (0.5-2.5 mm2)

    Female – SleevesFS103V FS106V

    20-14 AWG (0.5-2.5 mm2)

    Crimp Terminal Inserts 3 + G 6 + G+ 2 Control + 2 Control

    Male InsertMC403V MC406V

    (Order contacts below)

    Female InsertFC303V FC306V

    (Order contacts below)

    Crimp Contacts Wire AWG (mm2) Identification Female Male Switch/Control

    20 AWG (0.5 mm2) No Groove FP2000 MP2000 –

    18 AWG (0.75-1 mm2) 1 Groove FP1800 MP1800 CP1800

    16 AWG (1.5 mm2) 2 Grooves FP1600 MP1600 CP1600

    14 AWG (2.5 mm2) 3 Grooves FP1400 MP1400 CP1400

    12 AWG (4.0 mm2) No Groove FP1200 MP1200 –

    DIN Rail Adapter Mount Frames 3 + G 6 + G+ 2 Control + 2 Control

    125mm long, with base for AMF010 AMF016

    snapping onto DIN rail

    150mm long, with base for AMF110 AMF116

    snapping onto DIN railF

    Adapter Mount Frames allow “open”wiring inside closed panel enclosure.They also allow Inserts to be assembledas a separable Terminal Block device.

    3 + G+ 2 Control

    6 + G+ 2 Control

    Contacts Selection

    ControlContacts

    Make Last,Break First

    WT611TB

    Use small blade screwdriver to pushin wire entry tab for easy contactremoval.

    Groove

    For all Inserts

    For “V” Series Inserts

    31-40.pdf 4 1/5/2012 2:46:06 PM1-76.pdf 34 1/6/2012 10:52:56 AM

  • 35

    Pos-E-Kon™

    V Series 16 Amps 600 VAC

    POS-E-KONTM

    NPTBases – Standard Mount Entry Single Double Single Double

    Panel Base PB303V PB103EV PB306V PB106EV

    w/Cover PB403V PB406V

    1 X 1/2" BB403V BB003EV1 X 3/4" BB406V BB006EV2 X 1/2" BB503V BB103EV2 X 3/4" BB506V BB106EV

    1 X 1/2" BB603V n

    1 X 3/4" BB606V n

    2 X 1/2" BB703V n

    2 X 3/4" BB706V n

    Hoods – Standard Mount

    1 X 1/2" SH603V SH003V1 X 3/4" SH606V SH006V

    1 X 1/2" TH803V TH203V1 X 3/4" TH806V TH206V

    Coupler Hoods – In-line Coupler Hoods mate to Standard Hoods ONLY.

    1 X 1/2" CH803V CH603EV1 X 3/4" CH806V CH606EV

    LH003EV

    LH203EV

    PB203V n

    BB203V n

    BB303V n

    Post Bases accept Lever Hoods ONLY.

    Lever Locking TypeHousing

    Side Entry

    Top Entry

    For In-line, Portable or Special Service Connections

    Lever Hoods mate to Post Bases ONLY.

    Top Entry

    Number of Contacts + Ground Connection(3 + G)

    + 2 Control(6 + G)

    + 2 Control

    Box Base(no Cover)

    Box Basew/Cover

    Side Entryw/Levers

    Top Entryw/Levers

    LH006EV

    LH206EV

    Box Basew/Posts+ Cover

    PB206V n

    BB206V n

    BB306V n

    BASE

    BASE

    TO

    HOOD

    HOOD

    TO

    COUPLER

    COUPLER

    HOOD

    TO

    BASE

    HOODS

    HOODS

    BASES

    Bases – with Access Cover

    Panel Basew/Posts + Cover

    1 X 1/2"1 X 3/4"2 X 1/2"2 X 3/4"

    Lever Hoods – Rev. Lock

    1 X 3/4"

    1 X 3/4"

    Reverse Locking

    n Add “M” final suffix for metal cover option.

    Single Lever Double Lever

    31-40.pdf 5 1/5/2012 2:46:06 PM1-76.pdf 35 1/6/2012 10:52:56 AM

  • Pos-E-Kon™

    V Series 16 Amps 600 VAC

    36

    Crimp Tool Contacts Selection

    3, 6, 10, 16, 20, 26 & 32 Contacts+2 Control Contacts & Ground

    Install toMatching Series

    Hood/Base

    Screw Terminal Inserts10 + G 16 + G 20 + G 26 + G 32 + G

    +2 Control +2 Control +2 Control +2 Control +2 Control

    Male – PinsMS210V MS216V FS110V x2

    MS210V+2x MS216V

    20-14 AWG (0.5-2.5 mm2) MS216V

    Female – SleevesFS110V FS116V FS210V x2

    FS110V+2x FS116V

    20-14 AWG (0.5-2.5 mm2) FS116V

    Crimp Contacts Wire AWG (mm2) Identification Female Male Switch/Control

    20 AWG (0.5 mm2) No Groove FP2000 MP2000 –

    18 AWG (0.75-1 mm2) 1 Groove FP1800 MP1800 CP1800

    16 AWG (1.5 mm2) 2 Grooves FP1600 MP1600 CP1800

    14 AWG (2.5 mm2) 3 Grooves FP1400 MP1400 CP1400

    12 AWG (4.0 mm2) No Groove FP1200 MP1200 –

    DIN Rail Adapter Mount Frames 10 + G 16 + G

    150mm long, with base AMF124 AMF124for snapping onto DIN rail

    Adapter Mount Framesallow “open” wiringinside closed panel enclosure. They alsoallow Inserts to beassembled as a separableTerminal Block device.

    10 + G+ 2 Control

    16 + G+ 2 Control

    20 + G+ 2 Control

    26 + G+ 2 Control

    32 + G+ 2 Control

    Crimp Terminal Inserts10 + G 16 + G 20 + G 26 + G 32 + G

    +2 Control +2 Control +2 Control +2 Control +2 Control

    Male InsertMC410V MC416V MC410V x2

    MC410V+2x MC416V

    (Order contacts below) MC416V

    Female InsertFC310V FC316V FC310V x2

    FC310V+2x FC316V

    (Order contacts below) FC316V

    WT611TB

    Use small bladescrewdriver to push inwire entry tab for easycontact removal.

    Grooves

    For all “V” Series Inserts

    31-40.pdf 6 1/5/2012 2:46:06 PM1-76.pdf 36 1/6/2012 10:52:56 AM

  • 37

    Pos-E-Kon™

    V Series 16 Amps 600 VAC

    POS-E-KONTM

    Hoods – Standard Mount1 X 3/4" SH010V1 X 1" SH010V100 SH6481 X 1-1/4" SH748

    1 X 1/2" TH210V1 X 3/4" TH8481 X 1" TH948

    Post Bases accept Lever Hoods ONLY.

    Lever Locking TypeHousing

    Side Entry

    Top Entry

    Lever Hoods mate to Post Bases ONLY.

    Top Entry

    Number of Contacts + Ground ConnectionV10: (10 + G) or (16 + G)

    + 2 ControlV20: (20 + G) or (26 + G)or (32 + G) + 2 Control

    Box Base(no Cover)

    Box Basew/Cover

    Side Entryw/Levers

    Top Entryw/Levers

    Box Basew/Posts + Cover

    BASE

    BASE

    TO

    HOOD

    HOOD

    TO

    COUPLER

    COUPLER

    HOOD

    TO

    BASE

    HOODS

    HOODS

    BASES

    Bases – with Access Cover

    Panel Basew/Posts + Cover

    PB210V n

    1 X 3/4" BB210V n

    2 X 3/4" BB310V n

    Lever Hoods – Rev. Lock

    1 X 3/4" LH010EV

    1 X 3/4" LH210EV1 X 1" LH210V100

    For In-line, Portable or Special Service Connections

    Coupler Hoods – In-line Coupler Hoods mate to Standard Hoods ONLY.

    1 X 3/4" CH610EV1 X 1" CH610EV1001 X 1-1/4" CH610EV125

    Reverse Locking

    Single Lever Double Lever NPTBases – Standard Mount Entry Double Single

    PB110EV PB348Panel Base

    w/Cover PB448V

    1 X 3/4" BB010EV1 X 1" BB4482 X 3/4" BB110EV2 X 1" BB548

    1 X 3/4" 1 X 1" BB6482 X 3/4" 2 X 1" BB748

    31-40.pdf 7 1/5/2012 2:46:07 PM1-76.pdf 37 1/6/2012 10:52:56 AM

  • Pos-E-Kon™

    T Series 16 Amps 600 VAC

    38

    • High Temp 200°C Components• Corrosion Resistant

    Housings

    6 10 16 246, 10, 16 & 24 Contacts + Ground

    Install toMatching Series

    Hood/Base

    Screw Terminal Inserts 6 + G 10 + G 16 + G 24 + G

    Male – PinsMS206T MS210T MS216T MS224T

    20-14 AWG (0.5-2.5 mm2)

    Female – SleevesFS106T FS110T FS116T FS124T

    20-14 AWG (0.5-2.5 mm2)

    T Series Benefits• High temp 200°C rated inserts• Silicone Viton® seals for molded edge gaskets*• Corrosion resistant copper-free aluminum housings with special finish• New ergonomic thermoplastic handles rated UL94V-O • Electrostatic epoxy powder coated finish

    * Viton is a trademark of DuPont Dow Elastomers.

    31-40.pdf 8 1/5/2012 2:46:07 PM1-76.pdf 38 1/6/2012 10:52:56 AM

  • 39

    Pos-E-Kon™

    T Series 16 Amps 600 VAC

    POS-E-KONTM

    Box Base (no Cover)

    Lever Locking TypeHousing

    6 10 16 24Number of Contacts + Ground Connection

    High Temp 200°C

    Hoods – Standard Mount1 X 16 SH606T SH010T1 X 21 SH016T SH024T1 X 29 SH124T

    1 X 16 TH806T TH210T1 X 21 TH216T TH224T1 X 29 TH324T

    Coupler Hoods – In-line Coupler Hoods mate to Standard Hoods ONLY.

    1 X 16 CH806T CH610ET1 X 21 CH616ET CH624ET1 X 29 CH716ET CH724ET

    Side Entry

    Top Entry

    For In-line, Portable or Special Service Connections

    Top Entry

    BASE

    BASE

    TO

    HOOD

    HOOD

    TO

    COUPLER

    COUPLER

    HOODS

    Note: Hoods and Bases are green colored to denote special T series.

    Bases – Standard Mount Single Double Double Double

    Panel Base PB306T PB110ET PB116ET PB124ET

    1 X 16 BB406T BB010ET1 X 21 BB016ET BB024ET2 X 16 BB506T BB110ET2 X 21 BB116ET BB124ET

    Single Lever Double LeverPg

    MetricEntry

    31-40.pdf 9 1/5/2012 2:46:07 PM1-76.pdf 39 1/6/2012 10:52:56 AM

  • Pos-E-Kon™

    M Series

    40

    Mix and Match Modular Connections• Signal, fiber optic, control and power connections

    all in one connection point.

    • 2, 3, 5 and 7 slot insert holders provide unlimitedflexibility.

    • Standard single inserts:

    › 3 pole Coax Signal› 3 pole, 50A, 600 VAC› 4 pole +G, 5 pole 16A, 600VAC› 5 pole, 20A, 400VAC› 10 pole, 10A, 250VAC or 10 pole, POF

    (fiber optic)› 20 pole, 5A, 63VAC › Dummy block

    • Standard B series Hoods and Bases

    How to Specify© Select types of contacts/circuits (see above).

    © Select number of each (per insert above).

    © Add up to get holder sizee.g.: 2-POF + 2-50A + 8-10A = 3 inserts plus 3-slot holders.

    © Match holder size required to hood and baseoptions (mating).

    Easy insert removalContacts + Inserts + Insert Holder + Housing

    31-40.pdf 10 1/5/2012 2:46:08 PM1-76.pdf 40 1/6/2012 10:52:56 AM

  • 41

    Pos-E-Kon™

    M (3P Coax) Series 1.5 Amps 50 VAC

    POS-E-KONTM

    Tools

    Dummy Inserts 0

    Male Blind Insert: MC100Mfor place keeping in Insert Holder

    Female Blind Insert: FC000M

    for place keeping in Insert Holder

    Male Crimp Contacts

    Coax Pin & Sleeve 3 Positions

    Male Coax Pin Contact MCX500

    RG-174Cable Size/Type RG-179

    RG-316

    Male Coax Pin Cotact MCX510

    Cable Size/Type RG-58

    Female Coax Pin Contact FCX400

    RG-174Cable Size/Type RG-179

    RG-316

    Female Coax Pin Cotact FCX410

    Cable Size/Type RG-58

    Specifications

    Number of Poles 3

    Termination Method Crimp (or solder)

    Contacts Solid Drilled,3.6mm CoAxialCopper Alloy, GoldPlated

    Rated Current 1.5A

    Rated Voltage 50V

    Volume Resistance ≤6 milliohms

    Surge Impedance 50 Ohms

    Frequency Range 2 GHz

    Crimp Terminal Inserts 3P CoAx

    Male Insert MC303M

    Female Insert FC203M

    Female Crimp Contacts

    Crimping Tool CT700TB

    RG174, 179, 316 Crimp Die CD710TBRG58 Crimp Die CD720TB

    Contact Removal Tool RT000TB

    Insert Puller PT300TB

    Inserts

    Contacts

    41-45.pdf 1 1/5/2012 2:46:18 PM1-76.pdf 41 1/6/2012 10:52:56 AM

  • Pos-E-Kon™

    M (3P) Series 50 Amps 600 VAC

    42

    Female Crimp Pins

    Male Crimp PinsTools

    Pin & Sleeve 3 Positions

    1.5 mm2 16 AWG MP16SD50

    2.5 mm2 14 AWG MP14SD50

    4 mm2 12 AWG MP12SD50

    6 mm2 10 AWG MP10SD50

    10 mm2 8 AWG MP08SD50

    Specifications

    Number of Poles 3

    Termination Method Crimp

    Contacts Solid Drilled, 3.6mmCopper Alloy, SilverPlated

    Rated Current 50 Amp

    Rated Voltage 600V

    Rated Impulse Voltage 8.0 kV

    Test Voltage 4 kV

    Volume Resistance ≤1 milliohm

    1.5 mm2 16 AWG FP16SD50

    2.5 mm2 14 AWG FP14SD50

    4 mm2 12 AWG FP12SD50

    6 mm2 10 AWG FP10SD50

    10 mm2 8 AWG FP08SD50

    Dummy Inserts 0

    Male Blind Insert: MC100Mfor place keeping in Insert Holder

    Female Blind Insert: FC000M

    for place keeping in Insert Holder

    Crimp Terminal Inserts 3P

    Male Insert MC103M

    Female Insert FC003M

    Crimping Tool CT400TB

    RG174, 179, 316 Crimp Die CD710TB

    Contact Removal Tool RT000TB

    Insert Puller PT300TB

    Inserts

    Contacts

    41-45.pdf 2 1/5/2012 2:46:18 PM1-76.pdf 42 1/6/2012 10:52:56 AM

  • 43

    Pos-E-Kon™

    M (4/5P) Series 16 Amps 600 VAC

    POS-E-KONTM

    Female Crimp Pins

    Male Crimp Pins

    Crimp Terminal Inserts 4P +G

    Male Insert MC704M

    Female Insert FC604M

    CrimpingCT700TB

    Tool

    Crimping 20 – 16 AWG CD730TBDie 16 – 14 AWG CD740TB

    Contact 20 – 16 AWG CL010TBLocator 16 – 14 AWG CL020TB

    RT800TB

    PT300TB

    Pin & Sleeve

    0.5 – 1.5 mm2 20 – 16 AWG MP16RF16

    1.5 – 2.5 mm2 16 – 14 AWG MP14RF16

    2.5 – 4 mm2 12 AWG MP12RF16

    Specifications

    Number of Poles 4 +G5

    Termination Method Crimp

    Contacts Stamped & Rolled,2.5 mm CopperAlloy, Silver Plated

    Rated Current 16A

    Rated Voltage 600V

    Rated Impulse Voltage 8.0 kV

    Test Voltage 5.7 kV

    Volume Resistance ≤5 milliohms

    0.5 – 1.5 mm2 20 – 16 AWG FP16RF16

    1.5 – 2.5 mm2 16 – 14 AWG FP14RF16

    2.5 – 4 mm2 12 AWG FP12RF16

    Dummy Inserts 0

    Male Blind Insert: MC100Mfor place keeping in Insert Holder

    Female Blind Insert: FC000M

    for place keeping in Insert Holder

    Tools

    Crimp Terminal Inserts 5P

    Male Insert MC705M

    Female Insert FC605M

    ContactRemoval

    Tool

    InsertPuller

    Inserts

    Contacts

    4&5 Positions

    41-45.pdf 3 1/5/2012 2:46:18 PM1-76.pdf 43 1/6/2012 10:52:56 AM

  • Pos-E-Kon™

    M (5P) Series 20 Amps 400 VAC

    44

    Female Crimp Pins

    Male Crimp Pins

    Pin & Sleeve 5 Positions

    Crimp Terminal Inserts 5P

    Male Insert MC105M

    Female Insert FC005M

    0.5 mm2 20 AWG MP20SD20

    1.0 mm2 18 AWG MP18SD20

    1.5 mm2 16 AWG MP16SD20

    2.5 mm2 14 AWG MP14SD20

    4 mm2 12 AWG MP12SD20

    Specifications

    Number of Poles 5

    Termination Method Crimp

    Contacts Solid Drilled, 2.5 mmCopper Alloy, SilverPlated

    Rated Current 20A

    Rated Voltage 400V

    Rated Impulse Voltage 6.0 kV

    Test Voltage 3.5 kV

    Volume Resistance ≤2 milliohms

    0.5 mm2 20 AWG FP20SD20

    1.0 mm2 18 AWG FP18SD20

    1.5 mm2 16 AWG FP16SD20

    2.5 mm2 14 AWG FP14SD20

    4 mm2 12 AWG FP12SD20

    Dummy Inserts 0

    Male Blind Insert: MC100Mfor place keeping in Insert Holder

    Female Blind Insert: FC000M

    for place keeping in Insert Holder

    Inserts

    Contacts

    CrimpingCT700TB

    Tool

    Crimping 20 – 14 AWG CD750TBDie 12 AWG CD760TB

    Contact 20 – 14 AWG CL430TBLocator 12 AWG CL040TB

    RT000TB

    PT300TB

    Tools

    ContactRemoval

    Tool

    InsertPuller

    41-45.pdf 4 1/5/2012 2:46:18 PM1-76.pdf 44 1/6/2012 10:52:57 AM

  • 45

    Pos-E-Kon™

    M (10P) Series 10 Amps 250 VAC

    POS-E-KONTM

    Pin Contact Glass POF 1mm MPF530

    Sleeve Contact Glass POF 1mm FPF520

    Pin & Sleeve 10 Positions

    Identification Male

    0.37 mm2 22 AWG 1 MP22SD

    2.5 mm2 20 AWG 2 MP20SD

    4 mm2 18 AWG 3 MP18SD

    6 mm2 16 AWG 4 MP16SD

    10 mm2 14 AWG 5 MP14SD

    Specifications

    Number of Poles 10

    Termination Method Crimp

    Contacts Solid Drilled, 1.6 mmCopper Alloy, SilverPlated

    Rated Current 10A

    Rated Voltage 250V

    Rated Impulse Voltage 4.0 kV

    Test Voltage 2.2 kV

    Volume Resistance ≤3 milliohms

    Fiber Optic Pin and Sleeve

    Identification Female

    0.37 mm2 22 AWG 1 FP22SD

    2.5 mm2 20 AWG 2 FP20SD

    4 mm2 18 AWG 3 FP18SD

    6 mm2 16 AWG 4 FP16SD

    10 mm2 14 AWG 5 FP14SD

    Crimp Terminal Inserts 10P

    Male Insert MC110M

    Female Insert FC010M

    Female Sleeves

    Dummy Inserts 0

    Male Blind Insert: for MC100Mplace keeping in Insert Holder

    Female Blind Insert: for FC000Mplace keeping in Insert Holder

    Tools

    CrimpingWT80

    Tool

    RT614

    InsertPT300TB

    Puller

    Crimping Tools

    Fiber OpticCT610

    Crimp Tool

    PositioningFPS701

    Sleeve

    I.D.

    I.D.

    Male Pins

    ContactRemoval

    Tool

    Inserts

    Contacts

    41-45.pdf 5 1/5/2012 2:46:18 PM1-76.pdf 45 1/6/2012 10:52:57 AM

  • Pos-E-Kon™

    M(20P) Series 5 Amps 63 VAC

    46

    Male Pins

    CrimpingCT500TB

    Tool

    RT200TB

    InsertPT300TB

    Puller

    Pin & Sleeve 20 Positions

    0.25 mm2 28-24 AWG MP24GS

    0.5 mm2 24-20 AWG MP20GS

    Specifications

    Number of Poles 20

    Termination Method Crimp

    Contacts Stamped, Formed,1.0 mm Copper Alloy,Gold Plated

    Rated Current 5A

    Rated Voltage 63V

    Rated Impulse Voltage 4.0 kV

    Test Voltage 1.68 kV

    Volume Resistance ≤5 milliohms

    Tools

    0.25 mm2 28-24 AWG FP24GS

    0.5 mm2 24-20 AWG FP20GS

    Crimp Terminal Inserts 20P

    Male Insert MC120M

    Female Insert FC020M

    Female Sleeves

    Dummy Inserts 0

    Male Blind Insert: for MC100Mplace keeping in Insert Holder

    Female Blind Insert: for FC000Mplace keeping in Insert Holder

    ContactRemoval

    Tool

    Inserts

    Contacts

    46-50.pdf 1 1/5/2012 2:46:28 PM1-76.pdf 46 1/6/2012 10:52:57 AM

  • 47

    Pos-E-Kon™

    M Series B6 Housing 600 VAC: 2 Inserts

    POS-E-KONTM

    n Add “M” final suffix for metal cover option.

    Lever Locking Type

    Housing

    Side Entry

    Top Entry

    For In-line, Portable or Special Service Connections

    Coupler Hoods Coupler Hoods mate to Standard Hoods ABOVE.

    1 X 1/2" CH8061 X 3/4" CH806H0751 X 1" CH806H100

    Top Entry

    Insert Holders + HousingsSelect one each male and female 2-slot insert holders for B6 housings, then

    select two each of any male and female M series inserts from pp. 41-46.

    Hoods – Standard Mount

    1 X 1/2" SH6061 X 3/4" SH606H0751 X 1" SH606H100

    1 X 1/2" TH8061 X 3/4" TH806H0751 X 1" TH806H100

    2-slot Female Insert Holder

    F2F006M

    2-slot Male Insert Holder

    F2M106M

    BASE

    BASE

    TO

    HOOD

    HOOD

    TO

    COUPLER

    COUPLER

    HOODS

    NPTBases – Standard Mount Entry Single

    Panel Base PB306 n

    w/Cover PB406 n

    1 X 1/2" BB4061 X 3/4" BB406H075

    Box Base 1 X 1" BB406H100( no Cover ) 2 X 1/2" BB506

    2 X 3/4" BB506H0752 X 1" BB506H100

    1 X 1/2" BB606 n

    1 X 3/4" BB606H075 n

    Box Base 1 X 1" BB606H100 n

    w/Cover 2 X 1/2" BB706 n

    2 X 3/4" BB706H075 n

    2 X 1" BB706H100 n

    Single Lever

    46-50.pdf 2 1/5/2012 2:46:28 PM1-76.pdf 47 1/6/2012 10:52:57 AM

  • Pos-E-Kon™

    M Series B10 Housing 600 VAC: 3 Inserts

    48

    Lever Locking TypeHousing

    Side Entry

    Top Entry

    For In-line, Portable or Special Service Connections

    Coupler Hoods – In-line Coupler Hoods mate to Standard Hoods.

    1 X 1/2" CH810 CH610E1 X 3/4" CH810H075 CH610EH0751 X 1" CH810H100 CH610EH100

    Top Entry

    Select one each male and female 3-slot insert holders for B10 housings, then select three each of any male and female M series inserts from pp. 41-46.

    Hoods – Standard Mount1 X 1/2" SH610 SH0101 X 3/4" SH610H075 SH010H0751 X 1" SH610H100 SH010H100

    1 X 1/2" TH810 TH2101 X 3/4" TH810H075 TH210H0751 X 1" TH810H100 TH210H100

    3-slot Female Insert Holder

    F3F010M

    3-slot Male Insert Holder

    F3M110M Side Entryw/Lever(s)

    Top Entryw/Lever(s)

    PB210 n

    BB210 n

    BB210H075 n

    BB210H100 n

    BB310 n

    BB310H075 n

    BB310H100 n

    Post Bases accept Lever Hoods ONLY.

    Box + Postsw/Cover

    BASE

    BASE

    TO

    HOOD

    HOOD

    TO

    COUPLER

    COUPLER

    HOOD

    TO

    BASE

    HOODS

    HOODS

    BASES

    Lever Hoods – Reversed Lock Lever Hoods mate to Post Bases ONLY.

    1 X 1/2" LH010E1 X 3/4" LH010EH0751 X 1" LH010EH100

    1 X 1/2" LH210E1 X 3/4" LH210EH0751 X 1" LH210EH100

    Reverse Locking

    NPTBases – Standard Mount Entry Single Double

    Panel Base PB310 PB110E

    w/Cover PB410

    1 X 1/2" BB410 BB010E1 X 3/4" BB410H075 BB010EH075

    Box Base 1 X 1" BB410H100 BB010EH100( no Cover ) 2 X 1/2" BB510 BB110E

    2 X 3/4" BB510H075 BB110EH0752 X 1" BB510H100 BB110EH100

    1 X 1/2" BB610 n

    1 X 3/4" BB610H075 n

    Box Base 1 X 1" BB610H100 n

    w/Cover 2 X 1/2" BB710 n

    2 X 3/4" BB710H075 n

    2 X 1" BB710H100 n

    Bases – with Access Cover

    Panel Basew/Cover

    1 X 1/2"1 X 3/4"1 X 1"2 X 1/2"2 X 3/4"2 X 1"

    Single Lever Double Lever

    Insert Holders + Housings

    n Add “M” final suffix for metal cover option.

    46-50.pdf 3 1/5/2012 2:46:28 PM1-76.pdf 48 1/6/2012 10:52:57 AM

  • 49

    Pos-E-Kon™

    M Series B16 Housing 600 VAC: 5 Inserts

    POS-E-KONTM

    Lever Locking Type

    Housing

    Side Entryw/Posts

    Top Entryw/Posts

    Top Entryw/Lever(s)

    Select one each male and female 5-slot insert holders for B16 housings, then select five each of any male and female M series inserts from pp.41-46.

    Hoods – Standard Mount

    1 X 3/4" SH616* SH016*1 X 1" SH716 SH116H

    1 X 3/4" TH816* TH216*1 X 1" TH816H100 TH316H

    5-slot Female Insert Holder

    F5F016MNote: AF10F216M Optional InsertHolder available (+5 insert) Positions V -Z for B32 Housings.

    5-slot Male Insert Holder

    F5M116MNote: AF10M316M Optional InsertHolder available (+5 insert) Positions V -Z for B32 Housings.

    Side Entryw/Lever(s)

    Top Entryw/Lever(s)

    PB216 n

    BB216* n

    BB216H100 n

    BB316* n

    BB316H100 n

    Post Bases accept Lever Hoods ONLY.

    Box + Postsw/Cover

    *Available in Standard or HIGH Profile “H” configurations (add suffix).n Add “M” suffix for metal cover option.

    BASE

    BASE

    TO

    HOOD

    HOOD

    TO

    COUPLER

    COUPLER

    HOOD

    TO

    BASE

    HOODS

    HOODS

    BASES

    For In-line, Portable or Special Service ConnectionsCoupler Hoods – In-line Coupler Hoods mate to Standard Hoods ABOVE.

    1 X 3/4" CH816H CH616EH1 X 1" CH916H CH716EH

    Bases – with Access Cover

    Panel Basew/Cover

    1 X 3/4"1 X 1"2 X 1/2"2 X 3/4"2 X 1"

    Lever Hoods – Reversed Lock Lever Hoods mate to Post Bases ONLY.

    1 X 3/4" LH016E1 X 1" LH116EH

    1 X 3/4" LH216E1 X 1" LH316EH

    Reverse Locking

    NPTBases – Standard Mount Entry Single Double

    Panel Base PB316 PB116E

    w/Cover PB416

    1 X 3/4" BB416* BB016E*Box Base w/Lever 1 X 1" BB416H100 BB016EH100

    ( no Cover ) 2 X 3/4" BB516* BB116E*2 X 1" BB516H100 BB116EH100

    1 X 3/4" BB616* n

    Box Base w/Cover 1 X 1" BB616H100 n

    & Lever 2 X 3/4" BB716* n

    2 X 1" BB716H100 n

    Single Lever Double Lever

    Insert Holders + Housings

    46-50.pdf 4 1/5/2012 2:46:28 PM1-76.pdf 49 1/6/2012 10:52:57 AM

  • Pos-E-Kon™

    M Series B24 Housing 600 VAC: 7 Inserts

    50

    Single Lever Double Lever Lever Locking TypeHousing

    Side Entryw/Posts

    Top Entryw/Posts

    Top Entryw/Lever(s)

    Select one each male and female 7-slot insert holders for B24 housings, then select seven each of any male and female M series inserts from pp.41-46.

    Hoods – Standard Mount1 X 3/4" SH624 SH0241 X 1" SH724 SH1241 X 1-1/4"

    1 X 3/4" TH824 TH2241 X 1" TH924 TH3241 X 1-1/4"RIBBON CBL TH624RC‡ TH424RC‡

    7-slot Female Insert Holder

    F7F024MNote: AF1024M Optional InsertHolder available (+7 insert)Positions T-Z for B48Housings.

    7-slot Male Insert Holder

    F7M124MNote: F104M324M OptionalInsert Holder available (+7 insert) Positions T -Z for B48 Housings.

    Side Entryw/Lever(s)

    Top Entryw/Lever(s)

    PB224 n

    BB224 n

    BB324 n

    Post Bases accept Lever Hoods ONLY.

    Box Basew/Posts and

    Cover

    *Available in Standard or HIGH Profile “H” configurations (add suffix).n Add “M” final suffix for metal cover option.‡ See page 71 for ribbon cable kits.

    For In-line, Portable or Special Service Connections

    Coupler Hoods – In-line Coupler Hoods mate to Standard Hoods ONLY.

    1 X 3/4" CH824 CH624E1 X 1" CH924 CH724E

    RIBBON CBL CH824RC‡ CH724ERC‡

    BASE

    BASE

    TO

    HOOD

    HOOD

    TO

    COUPLER

    COUPLER

    HOOD

    TO

    BASE

    HOODS

    HOODS

    BASES

    Bases – with Access Cover

    Panel Basew/Posts and Cover

    1 X 3/4"2 X 3/4"

    Lever Hoods – Reversed Lock Lever Hoods mate to Post Bases ONLY.

    1 X 3/4" LH024E1 X 1" LH124E

    1 X 3/4" LH224E1 X 1" LH324E

    Reverse Locking

    NPTBases – Standard Mount Entry Single Double

    Panel Base PB324 PB124E

    w/Cover PB424

    1 X 3/4" BB424* BB024E*Box Base w/Lever 1 X 1" BB424H100 BB024EH100

    ( no Cover ) 2 X 3/4" BB524* BB124E*2 X 1" BB524H100 BB124EH100

    1 X 3/4" BB624* n

    Box Base w/Cover 1 X 1" BB624H100 n

    & Lever 2 X 3/4" BB724* n

    2 X 1" BB724H100 n

    Insert Holders + Housings

    46-50.pdf 5 1/5/2012 2:46:29 PM1-76.pdf 50 1/6/2012 10:52:57 AM

  • 51

    Pos-E-Kon™

    Reference and Accessories

    POS-E-KONTM

    Engineering Reference Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52-55Dimensions/Lay-In Charts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56-68Dust Covers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66Adapter Plate Selection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67Gaskets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68Insert Coding and Guide Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69Cable and Conduit Entry Options/Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70, 71Fiber Optic Cable Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72, 73

    51.pdf 1 1/5/2012 2:46:37 PM1-76.pdf 51 1/6/2012 10:52:57 AM

  • Pos-E-Kon™

    Engineering Reference

    52

    SpecificationsDIN VDE 0627/86 DIN VDE 0627/86DIN VDE 0110/02.79 DIN VDE 0110/02.79DIN VDE 0110-1/04.97 DIN VDE 0110-1/04.97IEC 60-664-1, DIN/IEC 512 IEC 60-664-1, DIN/IEC 512

    ApprovalsMEIE, EZU, SEV

    InsertsContacts ( +Ground ) 3,4,10,16,32 (2x16)Working current A3,A4 @ 10A max.

    A10 - A32 @ 16A max.Rated Voltage 600VACTest Voltage 4 kV eff.Pollution Degree 3Material Glass Filled ThermoplasticTemperature Range -40°C/-40°F to +125°C/+257°FFlammability UL94 V-0

    ContactsMaterial Solid drilled Copper alloySurface Hard Silver Plated

    Hard Gold Plated availableContact Resistance ≤ 1 milliohmScrew Terminals Wire AWG

    with Wire Protection 20-14 AWG (0.5-2.5mm2)Crimp Terminals 20-12 AWG (0.5-4.0mm2)

    HousingsMaterials Die Cast Aluminum alloy(EPDM Seal Gaskets) Epoxy Powder Coat FinishLocking Mechanisms

    > Single Locking Levers A3, 4, 10, 16Steel, Zinc or Chrome Plated

    > Double Locking Levers A32Steel, Zinc or Chrome Plated

    Temperature Range -40°C/-40°F to +125°C/+257°FInternal Protection A3,4: IP44 A10,16,32: IP65

    per DIN VDE 0470, IEC 529

    Thermal Capacity per DIN/IEC 512

    A Series

    SpecificationsDIN VDE 0627/86DDIN VDE 0110/02.79DIN VDE 0110-1/04.97IEC 60-664-1, DIN/IEC 512

    ApprovalsMEIE, EZU, SEV

    InsertsContacts ( +Ground ) 6,10,16,24, 32 (2x16), 48 (2x24)

    Working current 16A max.Rated Voltage 600VACTest Voltage 3 kV eff.Pollution Degree 3Material Glass Filled ThermoplasticTemperature Range -40°C/-40°F to +125°C/+257°FFlammability UL94 V-0

    ContactsMaterial Solid drilled Copper alloySurface Hard Silver Plated

    Hard Gold Plated availableContact Resistance ≤ 1 milliohmScrew Terminals Wire AWG

    with Wire Protection 20-14 AWG (0.5-2.5mm2)Crimp Terminals 20-12 AWG (0.5-4.0mm2)

    HousingsMaterials Die Cast Aluminum alloy(EPDM Seal Gaskets) Epoxy Powder Coat FinishLocking Mechanisms

    > Single Locking Levers B6, 10, 24, 32, 48Steel, Zinc or Chrome Plated

    > Double Locking Levers B10, 16, 24Stainless Steel w/ high impact

    Thermoplastic Split Grips> Double Locking Levers B32

    Steel, Zinc or Chrome PlatedTemperature Range -40°C/-40°F to +125°C/+257°FInternal Protection IP65 Locked Positions

    per DIN VDE 0470, IEC 529

    Thermal Capacity per DIN/IEC 512

    ® ®

    Conductor size 1mm Conductor size 2.5mmConductor size 1.5mm2 22

    Ambient temperature (° C )

    Rat

    ed o

    pera

    ting

    curr

    ent p

    er c

    onta

    ct (

    A )

    0

    2

    4

    6

    8

    I N 10

    12

    14

    16

    20 40 60 80 100 120 20 40 60 80 100 120 20 40 60 80 100 120

    A 10Crimp

    A 3

    A 16CrimpA 10

    Screw

    A 10Screw

    A 16Crimp

    A 10Screw

    A 3

    A 16Screw

    A 10Crimp

    A 16Screw

    A 10Crimp

    A 10Screw

    A 16Crimp

    A 3

    Conductor size 1mm2 Conductor size 2.5mm

    2

    Ambient temperature (° C )

    Rat

    ed o

    pera

    ting

    curr

    ent p

    er c

    onta

    ct (

    A )

    0

    I N 16

    14

    12

    10

    8

    6

    4

    2

    20 40 60 80 100 120 20 40 60 80 100 120

    B 24

    B 16

    B 6

    B 10

    B 16

    B 24

    B 10

    B 6

    B Series

    52.pdf 1 1/5/2012 2:46:44 PM1-76.pdf 52 1/6/2012 10:52:57 AM

  • 53

    Pos-E-Kon™

    Engineering Reference

    POS-E-KONTM

    SpecificationsDIN VDE 0627/86 DIN VDE 0627/86DIN VDE 0110/02.79 DIN VDE 0110/02.79DIN VDE 0110-1/04.97 DIN VDE 0110-1/04.97IEC 60-664-1, DIN/IEC 512 IEC 60-664-1, DIN/IEC 512

    ApprovalsMEIE, EZU, SEV

    InsertsContacts ( +Ground ) 6, 12 (2x6)Working current 35A

    Rated Voltage 600VACTest Voltage 3 kV eff.Pollution Degree 3Material Glass Filled ThermoplasticTemperature Range -40°C/-40°F to +125°C/+257°FFlammability UL94 V-0

    ContactsMaterial Solid drilled Copper alloySurface Hard Silver Plated

    Hard Gold Plated availableContact Resistance ≤ 0.5 milliohmScrew Terminals Wire AWG

    with Wire Protection 20-10 AWG (0.5-6.0mm2)w/o Wire Protection n/a

    HousingsMaterials Die Cast Aluminum alloy(EPDM Seal Gaskets) Epoxy Powder Coat FinishLocking Mechanisms

    > Single Locking Levers C6, 12Steel, Zinc or Chrome Plated

    > Double Locking Levers C6Stainless Steel w/high impact

    Thermoplastic Split Grips> Double Locking Levers C12

    Steel, Zinc or Chrome PlatedTemperature Range -40°C/-40°F to +125°C/+257°FInternal Protection IP65 Locked Positions

    per DIN VDE 0470, IEC 529

    Thermal Capacity per DIN/IEC 512

    SpecificationsDIN VDE 0627/86 DIN 43652DDIN VDE 0110/02.79DIN VDE 0110-1/04.97IEC 60-664-1, DIN/IEC 512

    ApprovalsMEIE, EZU, SEV

    InsertsContacts ( +Ground ) 7, 8, 15, 25, 40, 50 (2x25)

    64, 80 (2x40), 128 (2x64)Working current 10ARated Voltage 600VACTest Voltage 4 kV eff.Pollution Degree 3Material Glass Filled ThermoplasticTemperature Range -40°C/-40°F to +125°C/+257°FFlammability UL94 V-0

    ContactsMaterial Solid drilled Copper alloySurface Hard Silver Plated

    Hard Gold Plated availableContact Resistance ≤ 3 milliohmsCrimp Terminals Wire AWG

    26-14 AWG (0.14-2.25mm2)> Fibre Optic Cable POF {0} 1MM

    HousingsMaterials Die Cast Aluminum alloy(EPDM Seal Gaskets) Epoxy Powder Coat FinishLocking Mechanisms

    > Single Locking Levers D7, 8, 15, 25, 40, 64, 128Steel, Zinc or Chrome Plated

    > Double Locking Levers D40, 64Stainless Steel w/ high impact

    Thermoplastic Split Grips> Double Locking Levers D50, 80

    Steel, Zinc or Chrome PlatedTemperature Range -40°C/-40°F to +125°C/+257°FInternal Protection IP65 Locked Positions

    per DIN VDE 0470, IEC 529

    Thermal Capacity per DIN/IEC 512

    ® ®

    Ambient temperature ( ° C )

    Rat

    ed o

    pera

    ting

    curr

    ent p

    er c

    onta

    ct (

    A )