power conditioner w73a - sanyodenki.com · power factor correction function 10-year equipment...

8
POWER CONDITIONER W 73 A

Upload: others

Post on 20-Aug-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: POWER CONDITIONER W73A - sanyodenki.com · Power Factor Correction Function 10-Year Equipment Warranty Program With the isolated operation mode, AC power can be obtained from wind

POWER CONDITIONER

W73A

Page 2: POWER CONDITIONER W73A - sanyodenki.com · Power Factor Correction Function 10-Year Equipment Warranty Program With the isolated operation mode, AC power can be obtained from wind

00

2,000

4,000

6,000

8,000

10,000

100 200 300 400 500 600DC input voltage [V]

DC

inpu

t po

wer

[W] A maximum of 32 setting points enables the optimum

power generation for a given system.

The setting can be performed easily on the operation panel.

Input operating voltage range

Rated output voltage [3-phase 3-wire]

Rated output capacity

Operating ambient temperature

DC 150 to 570

AC 202

9.9

- 25 to + 60

IP65

Easy SettingsDC input voltage and power characteristics can be freely set according to the system to maximize the yield of wind and water turbines.

Operation start voltage and operation start time can also be set.

・Operation start voltage: 230 to 400 VDC (in increments of 1 V)

・Operation start time: 0 to 300 s (in increments of 1 s)

This product converts the power generated by wind pow-

er and hydroelectric power generation systems to output

3-phase AC power.

V

V

kW

Products for Japanese Market

°C

W73APower Conditioner for Wind Power and Hydro Power Generation Systems

2

Page 3: POWER CONDITIONER W73A - sanyodenki.com · Power Factor Correction Function 10-Year Equipment Warranty Program With the isolated operation mode, AC power can be obtained from wind

P61B

P73J

300 m 500 mP61B

Sho

relin

e

500 m

Test method

temperature

Salt water

concentrationSpray period

Storage duration

Storage duration

×4

1 cycle (1 week)

Chamber internal

Chamber internaltemperatureChamber internal humidity

Chamber internal temperatureChamber internal humidity

8 cycles (8 weeks)

15 to 35°C

5%

2 hours

40°C

93%

22 hours

23°C

45 to 55%

3 days

Ingress Protection Rating - IP65

This product can be installed at a distance of 500 m or more from the shoreline.

The W73A features superior waterproof and dustproof performance with an IP65 protection rating.

No malfunction or performance reduction was observed after this testing under an environment equivalent to salt damage areas. Note: Exterior discoloration and rust will not be covered by warranty.

Output power factor can be set between 0.8 and 1.0 in 0.01 increments.The rise in grid voltage can be easily suppressed by adjusting the power factor.

The standard 1-year warranty can be extended to 10 years as needed (with charge). Warranty conditions are contained in our terms and conditions.

I P 6 52nd digit ... Protection against low pressure water jets

1st digit ... Complete protection against dust

Salt Spray Test IEC60068-2-52 Severity 6

Power Factor Correction Function

10-Year Equipment Warranty Program

With the isolated operation mode, AC power can be obtained from wind power or hydro power generation systems even in the event of a

power outage or in places where power is not available. The grid-connected and isolated operation modes can be automatically switched.

Isolated Operation Provides Power During Outages

W73A

3

Page 4: POWER CONDITIONER W73A - sanyodenki.com · Power Factor Correction Function 10-Year Equipment Warranty Program With the isolated operation mode, AC power can be obtained from wind

Dimensions (unit: mm)

Specifications

Type name

Item

Grid-connected type Grid-connected isolated type Remarks

W73A992R W73A992S

Output capacity 9.9 kW

Main circuit type Self-commutated voltage type

Switching system High frequency PWM

Isolation method High frequency isolation

Cooling method Forced air cooling

DC Input

Rated voltage 400 VDC

Maximum allowable input voltage 570 VDC

Input operating voltage range 150 to 570 VDC Rated output range: 250 to 540 VDC

Grid-connected output

Number of input circuits 1 circuit

Number of phases and wires 3-phase 3-wire

Rated voltage 202 VAC

Rated frequency 50/60 Hz

Rated output current 28.3 AAC

AC output current harmonic distortion Total current: 5% or less; individual harmonics: 3% or less. When compared with rated output current

Output power factor 0.95 or greater At the rated output and a power factor of 1.0.Power factor setting range: 0.8 to 1.0 (in increments of 0.01 steps).

Efficiency 93% By the efficiency measurement method in accordance with JIS C 8961, at a power factor of 1.0.

Isolated output

Rated output - 9.9 kW

Number of phases and wires - 3-phase 3-wire

Rated voltage - 202 VAC

Voltage regulation - Within ± 8% of rated voltage

Rated frequency - 50/60 Hz

Frequency regulation - Within ±0.1 Hz of rated frequency

AC output current harmonic distortion - 5% or less at linear load

Overload capability - 100% continuous

Efficiency - 93% By the efficiency measurement method in accordance with JIS C 8961

Operation modes (grid-connected/isolated) switch setting -Automatic or manual (Factory setting: Manual)

Grid protectionOvervoltage relay (OVR), undervoltage relay (UVR), overfrequency relay (OFR), and underfrequency relay (UFR)

An overvoltage ground relay (OVGR) shall be externally connected to the factory-configured no-voltage b contact input.

Islanding detection Passive method Voltage phase jump detection

Active method Frequency feedback method with step injection*

Communication RS-485

Acoustic noise 50 dB or less A-weighted, 1 m from front of unit

Environment Ambient temperature -25 to +60°C Operates at derated output above 40°C.

Relative humidity 90% or less (no condensation)

Altitude 2,000 m or less

Paint color Munsell 5Y7/1 (semi gloss)

Generated heat 745 W

Mass 64 kg

* Contact our sales department when installing a large number of power conditioners or for centralized installations.

700

650

4-Ø14 Hook size

600

500

25 21

280

40

Cable entry opening3-Ø49

757575 75Cable entry opening2-Ø34

(252

.5)

67.5 120

50

600

700

650

4-Ø14 Hook size

600

500

25 21

280

40

Cable entry opening3-Ø49

757575 75Cable entry opening2-Ø34

(252

.5)

67.5 120

50

600

Bottom

W73A

4

Page 5: POWER CONDITIONER W73A - sanyodenki.com · Power Factor Correction Function 10-Year Equipment Warranty Program With the isolated operation mode, AC power can be obtained from wind

Configuration example

Operating parts

Circuit diagramGrid output

Grid outputIsolated output

Signal input

MCCB MC MCCB

DC input

Signal inputDC input

MCCB MC MCCB

MC

■ Grid-connected type ■ Grid-connected isolated type

Filter

Filter

Isolationconverter

DC / ACinvertercircuit

Operation and display circuit

Control circuit,grid protection circuit Operation and

display circuit

Control circuit,grid protection circuit

Filter

Filter

Isolationconverter

DC / ACinvertercircuit

Grid output circuit breaker

DC input switch

Operation and display panel

・ Terminal size: M5↓Grounding terminal

↓Grid output terminal・ Terminal size: M5

Control signal terminals

・ Terminal size: M3 & 5

PV Monitor

↓Isolated output terminal・ Terminal size: M5

Wind Power Generation and Hydroelectric Power Generation

Terminal section enlarged view

DC input terminal・ Terminal size: M6

Note: A communication cable for the PV Monitor shall be required.

W73A

5

Page 6: POWER CONDITIONER W73A - sanyodenki.com · Power Factor Correction Function 10-Year Equipment Warranty Program With the isolated operation mode, AC power can be obtained from wind

Options

・ Dedicated Installation Stand This frame is used for the upright installation when no walls are suitable

for installation. (Assembly required)

Model no. Material

STP73H01 Steel plate

STP73H02 Stainless steel

Dimensions (unit: mm)

Dimensions (unit: mm)

Dimensions (unit: mm)1,

100

75

25

600

644.8

644.

37

700

Waterproof flat handle

340.4

37.4

Key no. TAK60

Weight: Approx. 25 kg

Weight: 97 kg

350

450

75

450

2- Ø 3.

618.3

105

993 11.7

23.5

101

Mass: 25 kg (excluding power conditioner unit)

Weight: 13 kg (weather shelter only)

Power Conditioner

420

270

Plane handleOpaque white

LED indicator lamp

180Front face interior

MCCB2MCCB1

19.5

(10)

650

700

4- Ø 18

500

50400

Cable entry

U,V,E

・Isolated Output Transformer Model no.: TRP73H152SA01Converts single-phase 2-wire 200 VAC power to deliver 100 VAC power in outlets

・Isolated Output Scott-T TransformerConverts 3-phase 3-wire 200 VAC power to deliver single-phase 3-wire 100/200 VAC power in two circuits

1,10

0

75

25

600

644.8

644.

37

700

Waterproof flat handle

340.4

37.4

Key no. TAK60

Weight: Approx. 25 kg

Weight: 97 kg

350

450

75

450

2- Ø 3.

618.3

105

993 11.7

23.5

101

Mass: 25 kg (excluding power conditioner unit)

Weight: 13 kg (weather shelter only)

Power Conditioner

420

270

Plane handleOpaque white

LED indicator lamp

180Front face interior

MCCB2MCCB1

19.5

(10)

650

700

4- Ø 18

500

50400

Cable entry

U,V,E

1,10

0

75

25

600

644.8

644.

37

700

Waterproof flat handle

340.4

37.4

Key no. TAK60

Weight: Approx. 25 kg

Weight: 97 kg

350

450

75

450

2- Ø 3.

618.3

105

993 11.7

23.5

101

Mass: 25 kg (excluding power conditioner unit)

Weight: 13 kg (weather shelter only)

Power Conditioner

420

270

Plane handleOpaque white

LED indicator lamp

180Front face interior

MCCB2MCCB1

19.5

(10)

650

700

4- Ø 18

500

50400

Cable entry

U,V,E

Dimensions (unit: mm)

・ Weather Shelter Model no.: OCP73HJWA01This shelter is necessary when installing the power conditioner in a place

exposed to direct sunlight.1,

100

75

25

600

644.8

644.

37

700

Waterproof flat handle

340.4

37.4

Key no. TAK60

Weight: Approx. 25 kg

Weight: 97 kg

350

450

75

450

2- Ø 3.

618.3

105

993 11.7

23.5

101

Mass: 25 kg (excluding power conditioner unit)

Weight: 13 kg (weather shelter only)

Power Conditioner

420

270

Plane handleOpaque white

LED indicator lamp

180Front face interior

MCCB2MCCB1

19.5

(10)

650

700

4- Ø 18

500

50400

Cable entry

U,V,E

W73A

6

Page 7: POWER CONDITIONER W73A - sanyodenki.com · Power Factor Correction Function 10-Year Equipment Warranty Program With the isolated operation mode, AC power can be obtained from wind

Wind power or hydroelectric power generation site

Internet

System configuration example

Power Conditioner Mobile Communications Pack

Serial communication (RS-485)

Cloud server

Remote monitoring from personal computers and smart phonesUsing our cloud service SANUPS NET enables you to check the amount of the power generated as well as to download the

measurement data from a mobile laptop computer or a smart phone.

No need for setting up Internet accessWe will also provide the connection to the internet when you sign up for our Mobile Communications Pack.

Router

If using the PV Monitor without Mobile Communications Pack, the internet connection is to be provided by the customer.

Type C

Remote monitoring(PC or smart phone)

This service enables you to remotely monitor the status of the power conditioner via the internet.

It makes maintenance easier, providing long-lasting peace of mind.

Remote Monitoring Service (optional)

W73A

7

Page 8: POWER CONDITIONER W73A - sanyodenki.com · Power Factor Correction Function 10-Year Equipment Warranty Program With the isolated operation mode, AC power can be obtained from wind

CATALOG No. P1028B003 '19.3

The names of companies and/or their products specified in this catalog are the trade names, and/or trademarks and/or registered trademarks of such respective companies.Specifications are subject to change without notice.

Note: For any inquiry or consultation, please contact our sales department.

Notes before PurchaseBefore installing, assembling, and using the product, please read Instruction Manual carefully and use it properly.

When using this product in the following applications, consult us in advance because special considerations are required for operation, maintenance, and management.

(a) Medical equipment that may have direct effects on human life or human body.

(b) Trains, elevators, and other machinery that can cause injury.

(c) Socially and publicly important computer systems.

(d) Other equipment that is related to safety of human life and that can have major impact on maintenance of public functions.

For use in an environment where vibration is present, such as in a car or a ship, please consult us in advance.

Never attempt to disassemble or alter the product in any way.

For installation and maintenance work of the product, please consult us or properly licensed personnel.

Products listed in this catalog may be regulated by export laws and regulations in each country. When exporting these products, compliance with each country's respective export laws and regulations is highly recommended.

SANYO DENKI will not be liable for any direct or indirect damages or loss, including but not limited to equipment downtime, missed power sales revenue, business interruptions, increased power purchases, resulting from the use of or inability to use our products or services.

https://www.sanyodenki.com

TEL: +81 3 5927 1020

TEL: +86 21 6235 1107

TEL: +1 310 783 5400

TEL: +33 1 48 63 26 61

TEL: +852 2312 6250

468 Amapola Avenue Torrance, CA 90501, U.S.A.

3-33-1 Minami-Otsuka, Toshima-ku, Tokyo 170-8451, Japan

P.A. Paris Nord Ⅱ, 48 Allée des Erables-VILLEPINTE, BP.57286, F-95958 ROISSY CDG Cedex, France

Room 2106-2110, Bldg A, Far East International Plaza, No.319, Xianxia Road, Shanghai, 200051, China

TEL: +86 10 6522 2160Room1222, Tower B, Beijing COFCO Plaza, No.8 Jianguomennei Dajie, Dong Cheng District, Beijing 100005 China

Room 2305, 23/F, South Tower, Concordia Plaza, 1 Science Museum Road, TST East, Kowloon, Hong Kong

TEL: +86 755 3337 38682F 02-11, Shenzhen International Chamber of Commerce Tower, No.168 Fuhua 3 Road, Futian District, Shenzhen, 518048 China

TEL: +66 2261 8670388 Exchange Tower, 25th Floor, Unit 2501-1, Sukhumvit Road, Klongtoey, Klongtoey, Bangkok 10110 Thailand

Beijing Branch

TEL: +86 22 2320 1186Room AB 16th Floor TEDA Building, No. 256 Jie Fang Nan Road, Hexi District, Tianjin 300042 ChinaTianjin Branch

TEL: +86 28 8661 6901Room2105B, Block A, Times Plaza, 2 Zongfu Road, Jinjiang District, Chengdu, 610016 ChinaChengdu Branch

TEL: +49 6196 76113 0

TEL: +82 2 773 5623

TEL: +886 2 2511 3938

TEL: +65 6223 1071

Frankfurter Strasse 80-82, 65760 Eschborn, Germany

988 Toa Payoh North, #04-08, Singapore 319002

N-711, 7F, Chia Hsin 2nd Bldg., No.96, Sec.2, Zhongshan N. Rd., Taipei 10449, Taiwan

15F, KDB Building, 372, Hangang-daero, Yongsan-gu, Seoul, 04323, Korea

TEL: + 62 21 252 3202Summitmas II 4th Floor, Jl. Jend. Sudirman Kav.61-62, Jakarta 12190, IndonesiaIndonesia Representative Office

TEL: +82 51 796 5151 8F, CJ Korea Express Bldg., 119, Daegyo-ro, Jung-gu, Busan, 48943, KoreaBusan Branch