Power System Analysis Instructor: Sidra Mehmood LAB # 2 Steady State Analysis Objective Use the Powergui (graphical user interface) block Obtain the steady-state outputs of the system Software Requirements SimPowerSystems software requires the following products: MATLAB Simulink Simscape™. Steady State Analysis In order to facilitate the steady-state analysis of your circuit, a graphical user interface (GUI) is provided in the powerlib library. Copy the Powergui block into your circuit1 window and double-click the block icon to open it. From the Analysis tools menu of Powergui, select Steady-State Voltages and Currents. This opens the Steady State Tool window where the steady-state phasors

Upload: umar-aftab

Post on 22-Dec-2015

7 views

Category:

Documents


0 download

DESCRIPTION

Lab Tutorial

TRANSCRIPT

Page 1: Power System Lab

Power System Analysis Instructor: Sidra Mehmood

LAB # 2

Steady State Analysis

Objective

Use the Powergui (graphical user interface) block

Obtain the steady-state outputs of the system

Software Requirements

SimPowerSystems software requires the following products:

MATLAB

Simulink

Simscape™.

Steady State Analysis

In order to facilitate the steady-state analysis of your circuit, a graphical user interface (GUI) is

provided in the powerlib library. Copy the Powergui block into your circuit1 window and

double-click the block icon to open it. From the Analysis tools menu of Powergui, select Steady-

State Voltages and Currents. This opens the Steady State Tool window where the steady-state

phasors measured by the two measurement blocks are displayed in polar form.

Page 2: Power System Lab

Power System Analysis Instructor: Sidra Mehmood

Each measurement output is identified by a string corresponding to the measurement block

name. The magnitudes of the phasors U1 and U2 correspond to the peak value of the sinusoidal

voltages.

From the Steady State window you can also choose to display the steady-state values of the

source voltage or the steady-state values of states by checking either the Sources or

the States check box.

Page 3: Power System Lab

Power System Analysis Instructor: Sidra Mehmood

The state variable names contain the name of the block where the inductor or capacitor is found,

preceded by the Il_ prefix for inductor currents or the Uc_ prefix for capacitor voltages.

The sign conventions used for the voltages and currents of sources and state variables are

determined by the orientation of the blocks:

Inductor currents flowing in the arrow direction are considered positive.

Capacitor voltages are Vblock output - Vblock input.

Page 4: Power System Lab

Power System Analysis Instructor: Sidra Mehmood

Now, from the Tools menu of the powergui, select Initial Values of State Variables -->

Display or Modify Initial State Values. The initial values of the six state variables (three

inductor currents and three capacitor voltages) are displayed. These initial values are set in order

to start the simulation in steady state.