presentation of

22
Presentation of Presentation of ELIS PLZEŇ a. ELIS PLZEŇ a. s. s. The Czech Republic The Czech Republic Es 90349K/b Es 90349K/b

Upload: susan

Post on 11-Jan-2016

29 views

Category:

Documents


4 download

DESCRIPTION

Presentation of. ELIS PLZEŇ a. s. The Czech Republic. Es 90349K/b. Company profile. ELIS PLZE Ň a. s. leader in development and production of flow meters of liquids in the Czech Republic all products are from own development product range: ultrasonic flow meters of type SONOELIS - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Presentation of

Presentation ofPresentation of

ELIS PLZEŇ a. ELIS PLZEŇ a. s.s.

The Czech RepublicThe Czech RepublicEs 90349K/bEs 90349K/b

Page 2: Presentation of

Company profileCompany profile• ELIS PLZEŇ a. s.

• leader in development and production of flow meters of liquids in the Czech Republic• all products are from own development

• product range:

• ultrasonic flow meters of type SONOELIS• ultrasonic battery powered water meters of type FLOMIC• ultrasonic battery powered flow meters of type FLOMIC• induction flow meters of type FLONET• heat meters in water of type SONOTHERM • heat meters in steam of type STEAMTHERM• ultrasonic level meters of type LEVELIS

Page 3: Presentation of

Company historyCompany history

• 1990 ELIS PLZE1990 ELIS PLZEŇŇ Company founded Company founded

• 1991 New Heat meters in water launched1991 New Heat meters in water launched

• 1991 ELIS PLZE1991 ELIS PLZEŇŇ transformed to Limited company transformed to Limited company

• 1993 New Heat meters in steam launched1993 New Heat meters in steam launched

• 1993 New testing center build up for metrological 1993 New testing center build up for metrological

verification verification and and calibration of calorimetric counters for calibration of calorimetric counters for

heat metersheat meters

• 1995 New ultrasonic flow meters launched1995 New ultrasonic flow meters launched

Page 4: Presentation of

• 1997 ELIS PLZE1997 ELIS PLZEŇŇ transformed to Join stock company transformed to Join stock company

• 1998 New electromagnetic flow meters launched1998 New electromagnetic flow meters launched

• 1998 New testing center built up for metrological 1998 New testing center built up for metrological

verification verification and and calibration for flow meters in sizes calibration for flow meters in sizes

DN 25 to DN 200 DN 25 to DN 200 (1 inch to(1 inch to 8 inches)8 inches)

• 2002 New testing center build up for metrological 2002 New testing center build up for metrological

verification verification andand c calibration for sizes DN 15 to DN 40 alibration for sizes DN 15 to DN 40

(1/2(1/2"" to 1 ½ to 1 ½"") )

• 2003 New ultrasonic water meters with battery supply 2003 New ultrasonic water meters with battery supply

launched launched

Page 5: Presentation of

• 2005 Company certified ISO 9001 2005 Company certified ISO 9001

• 2006 Enlargement of testing center for new test rigs for 2006 Enlargement of testing center for new test rigs for

metrological verification and calibration of flow metrological verification and calibration of flow

meters,meters, calorimetric counters for heat meters and calorimetric counters for heat meters and

temperaturetemperature sensorssensors

• 2006 New ultrasonic flow meters with battery supply for big 2006 New ultrasonic flow meters with battery supply for big

dimension DN 200 to DN 2000 (8dimension DN 200 to DN 2000 (8"" to 80 to 80"") launched) launched

• 2006 New high pressure ultrasonic flow meters launched up 2006 New high pressure ultrasonic flow meters launched up

toto 160 bar160 bar (up to 2320 psi(up to 2320 psi))

• 20020077 New ultrasonic New ultrasonic level meters LEVELIS level meters LEVELIS launchedlaunched

Page 6: Presentation of

ORGANIZATION OF ELIS PLZEN a.s.

GENERAL GENERAL MEETINGMEETING

BOARD OF BOARD OF DIRECTORSDIRECTORS

SUPERVISORYSUPERVISORYBOARDBOARD

GENERAL MANAGERGENERAL MANAGER

SALES SALES DEPDEP

TECHNICALTECHNICALDEPDEP

REPS OF REPS OF MANAGEMENTMANAGEMENT

OFFICE OFOFFICE OFGENERAL GENERAL DIRECTORDIRECTOR

QUALITYQUALITYDEPDEP

METROLOGY METROLOGY DEPDEP

MAINTENANCEMAINTENANCEINSPECTINSPECT

PRODUCTPRODUCTDEPDEP

ACCOUNT AND ACCOUNT AND HUMEN RESOURCHUMEN RESOURC

DEPDEP

Page 7: Presentation of

Induction flow meter FLOInduction flow meter FLONETNET F FNN 20XX20XX

• Application:Application:precise measurement of flow of precise measurement of flow of

water and otherwater and other conductiveconductive liquidsliquids• Suitable for pipes:Suitable for pipes: DN 6 to DN 1200DN 6 to DN 1200

(¼" to 48")(¼" to 48")• Wide selection of pressure range:Wide selection of pressure range:

6 to 40 bar6 to 40 bar• Lining:Lining: Hard, soft, special rubber, Hard, soft, special rubber,

TeflonTeflon• Liquid temperature scale:Liquid temperature scale: 0 to 150°C0 to 150°C• High accuracy:High accuracy:• 0,2% in range 10 to 100% q0,2% in range 10 to 100% qss

0,5 in range 5 to 100% q0,5 in range 5 to 100% qss

• Communication interface:Communication interface: RS 485 RS 485

Page 8: Presentation of

Induction flow meter FLOInduction flow meter FLONETNET F FFF 110XX0XX

• Application:Application:precise measurement of flow of precise measurement of flow of

conductive liquids in food industryconductive liquids in food industry• Suitable for pipes:Suitable for pipes: DN 10 to DN 100 DN 10 to DN 100 ((¼" to 4")¼" to 4")• Pressure range: Pressure range: 10 bar10 bar• Design of sensor:Design of sensor: stainless steelstainless steel

• Type of connection: Type of connection: Tri ClTri Clampamp or Food screwed joint or Food screwed joint• Lining: Lining: TeflonTeflon• Liquid temperature scale:Liquid temperature scale: 00 to 150°Cto 150°C• High accuracy:High accuracy:

0,5% in range 5 to 100% q0,5% in range 5 to 100% qss

• Communication interface:Communication interface:RS 485 communication lineRS 485 communication line

Page 9: Presentation of

Induction flow meter Induction flow meter FLONET FR FLONET FR 10XX10XX

• Application:Application:precise measurement of flow of precise measurement of flow of waterwater and other conductive and other conductive liquidsliquids

• SuitableSuitable for pipes:for pipes: DN 6 to DN 1200 DN 6 to DN 1200

(¼" to 48")(¼" to 48")

• Wide selection of pressure rangeWide selection of pressure range:: 66 to 40 bar to 40 bar

• LiquidLiquid temperature scale:temperature scale: 0 to 0 to 15150°C0°C

• High accuracy:High accuracy:0,5% in range 5 to 100% q0,5% in range 5 to 100% qss

• Communication interface:Communication interface:HART HART oror FOUNDATION FOUNDATION

FIELDBUSFIELDBUS

Page 10: Presentation of

Induction flow meter Induction flow meter FLONET FFLONET FSS 10XX10XX

• Application:Application:precise measurement of flow of precise measurement of flow of conductive liquids with very high conductive liquids with very high abrasionabrasion

• Suitable for pipes:Suitable for pipes: DN 100 to DN 450 DN 100 to DN 450

(4" to 18")(4" to 18")• Pressure range:Pressure range: 10 and 16 10 and 16 bbarar• Design of sensor:Design of sensor: Wafer or FlangedWafer or Flanged• Lining:Lining: wear-resistant materialwear-resistant material• Liquid temperature scale:Liquid temperature scale: 0 to 0 to

15150°C0°C

• High accuracy:High accuracy:0,5% in range 5 to 100% q0,5% in range 5 to 100% qss

• Communication interface:Communication interface: HARTHART protocolprotocol

Page 11: Presentation of

Ultrasonic Ultrasonic flowflowmeter meter SONOELIS SE SONOELIS SE 40XX40XX

• ApplicationApplication:: precise measurementprecise measurement of of flow of flow of various clean liquidsvarious clean liquids

• Suitable for pipes: Suitable for pipes: DN 15 to DN 300DN 15 to DN 300

(1/2 inch to 12 inch)(1/2 inch to 12 inch)• Measuring method:Measuring method: transit timetransit time• Flow rate range:Flow rate range: 10 to 1000 m10 to 1000 m33/hod/hod• Pressure range:Pressure range: 116 or 40 bar6 or 40 bar• Liquid temperature scale:Liquid temperature scale: 0 to 150°C0 to 150°C

• High accuracy:High accuracy: 0,5% in range 5 to 100% q0,5% in range 5 to 100% qs s

- model SE 406X - dual beam- model SE 406X - dual beam 1% in range 5 to 100% q1% in range 5 to 100% qs s

- model SE 404X - single beam- model SE 404X - single beam• Communication interface:Communication interface:

RS 485 communication lineRS 485 communication line

Page 12: Presentation of

Ultrasonic Ultrasonic flow flow meter meter SONOELIS SE SONOELIS SE 404011XX and and SONOELIS SONOELIS SE 402XSE 402X

• ApplicationApplication: : precise measurement of flow of precise measurement of flow of various clean water various clean water

• Suitable for pipes: Suitable for pipes: DN 200 to DN 1200DN 200 to DN 1200

(8" to 48")(8" to 48")• Measuring method:Measuring method: transit timetransit time• Pressure range:Pressure range: 66 to 16 to 1600 bar bar• Liquid temperature scale:Liquid temperature scale: 00 to to

150°C150°C• High accuracy:High accuracy:

0,5%0,5% and better model SE and better model SE 402X - 402X -

dual beam SE 402Xdual beam SE 402X 1%1% and better model SE 401X – and better model SE 401X –

single beam SE 401Xsingle beam SE 401X• Communication interface:Communication interface:

RS 485 communication lineRS 485 communication line

Page 13: Presentation of

Ultrasonic Ultrasonic flow flow meter meter SONOELIS SE SONOELIS SE 80XX80XX

• Application:Application:precise measurement of water and cleanprecise measurement of water and clean

liquids in big pipelines by method ofliquids in big pipelines by method of DIRECT ASSEMBLYDIRECT ASSEMBLY• Suitable for pipes:Suitable for pipes:

DN 200 to DN 1200DN 200 to DN 1200 ((8 inch 48 inch8 inch 48 inch))

• Measuring method:Measuring method: transit timetransit time• Pressure range:Pressure range: up to 40up to 40 bar bar• Liquid temperature scale:Liquid temperature scale: 0 to 150°C 0 to 150°C • High accuracy by theoretical calibration:High accuracy by theoretical calibration:

1 %1 % and better model SE 806and better model SE 806XX – – - dual beam- dual beam

2 %2 % and better model SE and better model SE 880404XX - single beam- single beam• Communication interface:Communication interface: RS 485 communication RS 485 communication

lineline

Page 14: Presentation of

Ultrasonic waterUltrasonic water meter FLOMIC FL meter FLOMIC FL 102102XX

• Application:Application:measurement of flow, water consumption and measurement of flow, water consumption and pressurepressure

intended for finding intended for finding of of water leakagewater leakage • Suitable for sizes:Suitable for sizes: DN 32 to DN 200DN 32 to DN 200

(1 ¼" to 8")(1 ¼" to 8")• Rated flow range:Rated flow range: 6 to 250 m6 to 250 m33/h/hourour• Rated pressure:Rated pressure: 16 bar 16 bar• Measuring method:Measuring method: transit time transit time• Flowrate sampling periodFlowrate sampling period:: 1 s 1 secec• Accuracy class:Accuracy class: B as per ISO 4064-1B as per ISO 4064-1• Electrical outputs:Electrical outputs: pulse and currentpulse and current• Storage datesStorage dates• Communication interface:Communication interface: IR, RS 232, M-BusIR, RS 232, M-Bus• Protection class: Protection class:

compact version (IP 67)compact version (IP 67)remote version (IP 68)remote version (IP 68)

Battery powered!Battery powered! Live of battery 8 Live of battery 8

years!years!

Page 15: Presentation of

Ultrasonic Ultrasonic flow flow meter FLOMIC FL 10meter FLOMIC FL 103X3X

• Application:Application:measurement of flow, water measurement of flow, water consumption and pressure consumption and pressure

• Suitable for pipes:Suitable for pipes: DN 32 to DN 300DN 32 to DN 300

((1 ¼" to 12"1 ¼" to 12"))• Rated flow range:Rated flow range: 0.04 to 3125 0.04 to 3125

mm33/h/hourour• Rated pressure:Rated pressure: 16 and 40 bar16 and 40 bar• Measuring method:Measuring method: transit time transit time• Flowrate sampling periodFlowrate sampling period:: 1 s 1 secec• Accuracy:Accuracy: according to EN 14154 according to EN 14154• Electrical outputs:Electrical outputs: pulse and currentpulse and current• DDatata storagea storage• Communication interface:Communication interface:

IR, RS 232, M-BusIR, RS 232, M-Bus• Protection class: Protection class:

compact version (IP 67)compact version (IP 67)remote version (IP 68)remote version (IP 68)

Battery powered!Battery powered! Live of battery 8 Live of battery 8

years!years!

Page 16: Presentation of

Ultrasonic flow meter FLOMIC FL Ultrasonic flow meter FLOMIC FL 30053005

• Application:Application:precise measurement of water precise measurement of water and cleanand clean liquids in big pipelines liquids in big pipelines by method of DIRECT ASSEMBLYby method of DIRECT ASSEMBLY

• Suitable for pipes:Suitable for pipes:DN 200 to DN 2000DN 200 to DN 2000

(8" to 80") (8" to 80") • Measuring method:Measuring method: single beam, transit timesingle beam, transit time• Flowrate sampling periodFlowrate sampling period: : 1 s1 secec• Pressure range:Pressure range: 16 bar, 40 bar16 bar, 40 bar• Liquid temperature scale:Liquid temperature scale: 0 to 0 to

150°C 150°C • High accuracy by theoretical High accuracy by theoretical

calibration:calibration:2% and better 2% and better

• Communication interface:Communication interface: IR, RS IR, RS 232232

Battery powered!Battery powered!Live time of Live time of battery battery 4 years4 years!!

Page 17: Presentation of

Ultrasonic flow meter FLOMIC FL Ultrasonic flow meter FLOMIC FL 30853085

• Application:Application:measurement of flow rate and water measurement of flow rate and water consumptionconsumption Suitable for pipes:Suitable for pipes:

DN 200 to DN 1200DN 200 to DN 1200 (8" to 48")(8" to 48")• Nominal flow range:Nominal flow range: 2.3 to 20.000 2.3 to 20.000 mm33/ho/hourur• Nominal pressure:Nominal pressure: 66 to 40 bar to 40 bar• Measuring method:Measuring method: single beam, transit timesingle beam, transit time• Flowrate sampling periodFlowrate sampling period:: 1 sec1 sec • Battery powered:Battery powered: live time of battery min 4 live time of battery min 4

yearyear• Accuracy class:Accuracy class: 1%1% and better and better • Electrical outputs:Electrical outputs: pulse and currentpulse and current• DDatata sa storage torage • Communication interface:Communication interface: M-Bus, RS 232M-Bus, RS 232

Battery powered!Battery powered!Live time ofLive time of batterybattery 4 years! 4 years!

Page 18: Presentation of

Ultrasonic wUltrasonic waterater meter FLOMIC FL meter FLOMIC FL 5024 and FLOMIC FL 50445024 and FLOMIC FL 5044

• Application:Application:measurement of flow, water measurement of flow, water consumptionconsumption and pressureand pressure

intended for finding intended for finding of of water water leakageleakage

• Suitable for sizes:Suitable for sizes: DN 32 to DN 200DN 32 to DN 200

(1 ¼" to 8")(1 ¼" to 8")• Measurement method:Measurement method:

single beam (FL 5024) single beam (FL 5024) dual beam (FL 5044 up DN 65)dual beam (FL 5044 up DN 65)• Rated flow range:Rated flow range: 1010 to to 40400 m0 m33/h/hourour• Rated pressure: Rated pressure: MAPMAP 1616• Measuring method: Measuring method: transit timetransit time• Flowrate sampling periodFlowrate sampling period: : 1 s1 secec• Accuracy class:Accuracy class: according to EN 14154according to EN 14154• Electrical outputs:Electrical outputs: pulse and currentpulse and current• datdata storagea storage• Communication interface:Communication interface:

USB, USB, RS 232RS 232, GSM module, GSM module• Protection class: Protection class: IP 68IP 68

Battery powered!Battery powered!Live time ofLive time of batterybattery 8 8 years! years!

Page 19: Presentation of

Ultrasonic flow meter FLOMIC FL Ultrasonic flow meter FLOMIC FL 5034 and FLOMIC FL 50545034 and FLOMIC FL 5054

• Application:Application:measurement of flow, water measurement of flow, water consumption and pressure consumption and pressure

• Suitable for pipes:Suitable for pipes: DN 32 to DN 300DN 32 to DN 300

((1 ¼" to 12"1 ¼" to 12"))• Measurement method: Measurement method:

single beam (FL 5034) single beam (FL 5034) dual beam (FL 5054 up DN 40)dual beam (FL 5054 up DN 40)• Rated flow range:Rated flow range: 1616 to to 10001000 m m33/h/hourour• PPressureressure class class:: MAP MAP 16 and 16 and MAP MAP 4040• Measuring method: Measuring method: transit timetransit time• Flowrate sampling periodFlowrate sampling period: : 1 s1 secec• Accuracy Accuracy class class: : according to EN 14154according to EN 14154• Electrical outputs:Electrical outputs: pulse and currentpulse and current• ddatata storagea storage• Communication interface:Communication interface:

USB, USB, RS 232RS 232, GSM module, GSM module• Protection class: Protection class: IP 68IP 68

Battery powered!Battery powered!Live time ofLive time of batterybattery 8 8 years! years!

Page 20: Presentation of

Ultrasonic level meter LEVELIS LU-55Ultrasonic level meter LEVELIS LU-55

• Application:Application:is used to continuouslyis used to continuously monitor level height monitor level height of liqud media, sludge or suspensations in of liqud media, sludge or suspensations in tanks, sumps, canalstanks, sumps, canals

• Measurement rangeMeasurement range:: 0.25 to 10m0.25 to 10m• Minimum dead zoneMinimum dead zone:: 0.2m0.2m• Wave radiation angleWave radiation angle:: 10 to 12°10 to 12°• Power sourcePower source:: 12 to 30V DC12 to 30V DC• OutputOutput: : 4 to 20mA4 to 20mA• AccuracyAccuracy: :

0.30.3%% (LU - 55N - 10, LU - 55N - 6) (LU - 55N - 10, LU - 55N - 6) 0.5% (LU - 55N - 2)0.5% (LU - 55N - 2)

• Protection classProtection class:: IP 65/IP 67IP 65/IP 67• 3 design options: 3 design options:

LU - 55N - 10 - measurement range up to LU - 55N - 10 - measurement range up to 10m10m

LU - 55N - 6 - measurement range up to 6mLU - 55N - 6 - measurement range up to 6m

LU - 55N - 2 - measurement range up to 2mLU - 55N - 2 - measurement range up to 2m• Display unitDisplay unit is possible to connect to is possible to connect to

LEVELIS LU - 55LEVELIS LU - 55

Page 21: Presentation of

Calibration test rigs of flow meters Calibration test rigs of flow meters of ELIS PLZEof ELIS PLZEŇ Ň a.a. s.s.

• Smaller dimensions DN 15 to DN 40Two Two of test rigs for calibration and of test rigs for calibration and measurement of flow meters DN 15 to DN measurement of flow meters DN 15 to DN 40 (1/2" to 1 ½")40 (1/2" to 1 ½")

MainMain standard – weight, second standards standard – weight, second standards – –

3 pcs of induction flow meters 3 pcs of induction flow meters

Measurement method – flying start, Measurement method – flying start, steadysteady start start

Flow rate 6 l/hFlow rate 6 l/houour to 12 mr to 12 m33/h/houourr

• Larger dimensions DN 25 to DN 150Larger dimensions DN 25 to DN 150Two Two of test rigs for calibration and of test rigs for calibration and measurement of flow meters DN 25 to DN measurement of flow meters DN 25 to DN 100 or DN 150 (1" to 4" or 6")100 or DN 150 (1" to 4" or 6")

MainMain standards – 2 pcs of weights, standards – 2 pcs of weights, second standards – 3 pcs of induction flow second standards – 3 pcs of induction flow meters meters

Measurement method – flying start, Measurement method – flying start, steady startsteady start

Flow rate 0.15 Flow rate 0.15 mm33/h/hourour to 150 m to 150 m33/h/houourr

Page 22: Presentation of

Contact of ELIS PLZEContact of ELIS PLZEŇŇ a. s. a. s.

ELIS PLZEŇ a. s.ELIS PLZEŇ a. s.Luční 15, P. O. BOX 126Luční 15, P. O. BOX 126304 26 Plzeň304 26 PlzeňCzech RepublicCzech Republic• PhonePhone.: +420-377 517 .: +420-377 517

711711• Fax: +420-377 517 722Fax: +420-377 517 722

• e-mail: e-mail: [email protected]• http://www.elis.cz

• ask for special offer dedicated to your facilityask for special offer dedicated to your facility

• ask for your nearest consultation company ask for your nearest consultation company visitvisit