  • AFT Fathom 7.0 Output 22-09-2014National Defunct Lab

    AFT Fathom Model

    General

    Title: AFT Fathom ModelAnalysis run on: 22-09-2014 14:35:57 Application version: AFT Fathom Version 7.0 (2009.11.02)Input File: D:\prob3_shubham.fthOutput File: D:\prob3_shubham_1.out Execution Time= 0.02 secondsTotal Number Of Head/Pressure Iterations= 0Total Number Of Flow Iterations= 2Total Number Of Temperature Iterations= 2Number Of Pipes= 1Number Of Junctions= 2Matrix Method= Gaussian Elimination Pressure/Head Tolerance= 0.0001 relative changeFlow Rate Tolerance= 0.0001 relative changeTemperature Tolerance= 0.0001 relative changeFlow Relaxation= (Automatic)Pressure Relaxation= (Automatic) Heat Transfer with Energy BalanceFluid Database: AFT StandardFluid: Water at 1 atmMax Fluid Temperature Data= 212 deg. FMin Fluid Temperature Data= 32 deg. FDefault Temperature= 21 deg. CDefault Density= 62.30989 lbm/ft3Default Viscosity= 2.36665 lbm/hr-ftDefault Vapor Pressure= 0.35901 psiaViscosity Model= Newtonian Atmospheric Pressure= 1 atmGravitational Acceleration= 1 gTurbulent Flow Above Reynolds Number= 4000Laminar Flow Below Reynolds Number= 2300

    Total Inflow= 4.500 kg/secTotal Outflow= 4.500 kg/secTotal Energy Inflow= 1,226 kWTotal Energy Outflow= 768.7 kWMaximum Static Pressure is 0.3448 MPa at Pipe 1 InletMinimum Static Pressure is 0.3440 MPa at Pipe 1 OutletMaximum Static Temperature is 65.00 deg. C at Junction 1 InletMinimum Static Temperature is 40.74 deg. C at Junction 2 Inlet

    Warnings

    ***WARNING*** HGL, EGL and head loss results may not be meaningful for variable density systems.

    Pipe Output Table

    Pipe Name

    1 Pipe

    Vol.

    Flow Rate

    (m3/sec)

    4.558E-03

    Velocity

    (meters/sec)

    0.5550

    P Static

    Max

    (MPa)

    0.3448

    P Static

    Min

    (MPa)

    0.3440

    Elevation

    Inlet

    (meters)

    0

    Elevation

    Outlet

    (meters)

    0

    dP Stag.

    Total

    (MPa)

    8.910E-04

    dP Static

    Total

    (MPa)

    8.910E-04

    dP

    Gravity

    (MPa)

    0

    dH

    (meters)

    0.09203

    Pipe P Static

    In

    (MPa)

    1 0.3448

    P Static

    Out

    (MPa)

    0.3440

    P Stag.

    In

    (MPa)

    0.3450

    P Stag.

    Out

    (MPa)

    0.3441

    Heat

    Flux

    (kW/m2)

    -47.33

    Heat

    Rate

    (kW)

    -456.1

    T

    Inlet

    (deg. C)

    65.00

    T

    Outlet

    (deg. C)

    40.74

    All Junction Table

    Jct Name

    1 Assigned Pressure

    P Static

    In

    (MPa)

    0.3448

    P Static

    Out

    (MPa)

    0.3448

    P Stag.

    In

    (MPa)

    0.3450

    P Stag.

    Out

    (MPa)

    0.3450

    Vol. Flow

    Rate Thru Jct

    (m3/sec)

    4.558E-03

    Mass Flow

    Rate Thru Jct

    (kg/sec)

    4.500

    Loss

    Factor (K)

    0

    2 Assigned Flow 0.3440 0.3440 0.3441 0.3441 4.558E-03 4.500 0

    (1 of 1)