protection technology group usa_catalog_2011-2012

153
Power and Signal Integrity Solutions RF | AC | DC | Data Protection

Upload: pt-bumi-raya-perkasa

Post on 20-Apr-2015

385 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Protection Technology Group USA_CATALOG_2011-2012

Power and Signal Integrity Solutions™

RF | AC | DC | Data Protection

Page 2: Protection Technology Group USA_CATALOG_2011-2012

Coaxial RF Surge ProtectionUltra Low PIMDC BlockDC PassGrounding and Accessories

Data Line Surge ProtectionMulti-Protocol ProtectorsPoE ProtectorsGbE ProtectorsT1/E1 ProtectorsCCTV | Satellite ProtectorsLow Voltage Signal Protectors

AC Surge ProtectionPanel ProtectorsPlug-In ProtectorsComponent Protectors

DC Surge ProtectionComponent ProtectorsOutdoor Protectors

Power Distribution PanelsPrimary | Secondary Distribution

Integrated Power CabinetsOutdoor CabinetsIndoor Cabinets

Application DiagramsTelecommunicationsRail TransportationOil and Gas

Page 3: Protection Technology Group USA_CATALOG_2011-2012

A global manufacturer of proprietary coaxial RF surge protection solutions, PolyPhaser leads the market with innovative DC Block and DC Pass RF product portfolio.

As a market leader in silicon diode technology, Transtector engineers and manufactures a diverse product offering that includes AC, DC, data/signal, EMP, power conditioners, UPS, power distribution units and integrated cabinets.

Founded on the ability to provide custom engineered solutions, Dowin’s lightning protection solutions include AC, DC and signal systems including analog, digital and RF.

Dedicated to the design, testing and manufacturing of TVSS based equipment, LEA specializes in series filters and parallel surge protection devices used in new construction, broadcast and alternative power markets.

For over 20 years RO Associates has been committed to providing expertise and professional assistance in power and grounding consulting and educational courses.

The Protection Technology Group is a part of Smiths Interconnect, a division of Smiths Group plc, and includes five brands:

By synergistically combining the expertise of the individual brands, the Protection Technology Group is able to provide the best end-to-end power quality solutions for the telecommunications, medical imaging, transportation, energy, security, broadcast and military markets.

Visit www.protectiongroup.com for additional product information, market applications and corporate resources.

Page 4: Protection Technology Group USA_CATALOG_2011-2012

Our manufacturing facilities are ISO 9001:2008 and ISO 14001: 2004 certified. The Protection Technology Group is committed to quality and ensures all R&D, testing, manufacturing, product inspection and sales fully comply with ISO standards and regulations.

Meeting our customers’ needs will always be paramount to the Protection Technology Group’s efforts in creating highly satisfied customers. We lead the industry in on-time delivery and continually strive to engineer and manufacture power and signal integrity products that provide our customers with the highest quality solutions at competitive pricing.

Our companies were founded on the ability to provide custom engineered solutions for unique protection circumstances. Regardless of your requirements, PolyPhaser, Transtector, Dowin, and LEA have the proven ability to design, develop and manufacture the solution.

Our engineers are business leaders and decision makers within regulatory agencies including IEC, IEEE, UL, IWPC, AISG and NEC. We continually strive to meet the needs of our customers by providing innovative product offerings for global markets.

Smiths Interconnect is a leading provider of specialized electronic and radio frequency products for the wireless telecommunications, aerospace, defense, and medical markets. It is part of Smiths Group, a global leader in advanced technologies. Smiths Group is comprised of 140 businesses grouped into five divisions in over 50 countries and employs 23,000 people in more than 400 locations.

Page 5: Protection Technology Group USA_CATALOG_2011-2012

5RF Intro Page

Whether your coaxial application is at the tower top, GPS or in the base station, PolyPhaser RF products have set the

standard for the industry.

Page 6: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Coaxial RF Surge Protection6

• PIM < -155 dBc

• Bidirectional broadband filter

• Bulkhead mount

• Tri-M3™ plating over brass

Features

• IEC 60529 IP 67

• Belcore #TA-NWT-000487

• Procedure 4.11, Wind Driven (120 MPH)

Standards and CertificatesTSXDC-DFM

Humidity < 95% non-condensing

Operating Temperature -50° C to +85° C

TSXDC-DFM

High performance, ultra low PIM RF protectors for 698 MHz to 2.5 GHz available in DC block and DC pass configurations.

Ultra Low PIM

TSX Series

Environmental

Page 7: Protection Technology Group USA_CATALOG_2011-2012

7

TSX-DFF

TUSX-DFM

Page 8: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Coaxial RF Surge Protection8

Frequency Range RF Power Insertion Loss VSWR Operating Voltage Max Surge Current Turn on Voltage Throughput EnergySurge Side Connector

Protected Side Connector

TSXDC-DFM 698 MHz to 2.5 GHz 1 kW @ 920 MHz ≤ 0.1 dB < 1.2:1 over frequency range ± 60 Vdc

20 kA per IEC 61000-4-5 8/20 µs waveform for multiple strikes / 30 kA per IEC 61000-4-5 8/20 µs waveform for one strike

+150 Vdc + 20%< 25 mJ 2kA IEC 61000-4-5 8/20 µs waveform

DIN Female DIN Male TSXDC-DFM

TSX-DFF 698 MHz to 2.7 GHz 1 kW @ 920 MHz ≤ 0.1 dB < 1.1:1 over frequency range N/A

20 kA per IEC 61000-4-5 8/20 µs waveform for multiple strikes / 30 kA per IEC 61000-4-5 8/20 µs waveform for one strike

N/A< 5 nJ for 3kA 8/20 µs waveform

DIN Female DIN Female TSX-DFF

TSX-DFM 698 MHz to 2.7 GHz 1 kW @ 920 MHz ≤ 0.1 dB < 1.1:1 over frequency range N/A

20 kA per IEC 61000-4-5 8/20 µs waveform for multiple strikes / 30 kA per IEC 61000-4-5 8/20 µs waveform for one strike

N/A< 5 nJ for 3kA 8/20 µs waveform

DIN Female DIN Male TSX-DFM

TUSX-DFF 300 MHz to 1.4 GHz 1 kW @ 920 MHz ≤ 0.1 dB < 1.1:1 over frequency range N/A

30 kA per IEC 61000-4-5 8/20 µs waveform for multiple strikes / 40 kA per IEC 61000-4-5 8/20 µs waveform for one strike

N/A< 5 nJ for 3kA 8/20 µs waveform

DIN Female DIN Female TUSX-DFF

TUSX-DFM 300 MHz to 1.4 GHz 1 kW @ 920 MHz ≤ 0.1 dB < 1.1:1 over frequency range N/A

30 kA per IEC 61000-4-5 8/20 µs waveform for multiple strikes / 40 kA per IEC 61000-4-5 8/20 µs waveform for one strike

N/A< 5 nJ for 3kA 8/20 µs waveform

DIN Female DIN Male TUSX-DFM

Ultra Low PIM

Page 9: Protection Technology Group USA_CATALOG_2011-2012

9

Frequency Range RF Power Insertion Loss VSWR Operating Voltage Max Surge Current Turn on Voltage Throughput EnergySurge Side Connector

Protected Side Connector

TSXDC-DFM 698 MHz to 2.5 GHz 1 kW @ 920 MHz ≤ 0.1 dB < 1.2:1 over frequency range ± 60 Vdc

20 kA per IEC 61000-4-5 8/20 µs waveform for multiple strikes / 30 kA per IEC 61000-4-5 8/20 µs waveform for one strike

+150 Vdc + 20%< 25 mJ 2kA IEC 61000-4-5 8/20 µs waveform

DIN Female DIN Male TSXDC-DFM

TSX-DFF 698 MHz to 2.7 GHz 1 kW @ 920 MHz ≤ 0.1 dB < 1.1:1 over frequency range N/A

20 kA per IEC 61000-4-5 8/20 µs waveform for multiple strikes / 30 kA per IEC 61000-4-5 8/20 µs waveform for one strike

N/A< 5 nJ for 3kA 8/20 µs waveform

DIN Female DIN Female TSX-DFF

TSX-DFM 698 MHz to 2.7 GHz 1 kW @ 920 MHz ≤ 0.1 dB < 1.1:1 over frequency range N/A

20 kA per IEC 61000-4-5 8/20 µs waveform for multiple strikes / 30 kA per IEC 61000-4-5 8/20 µs waveform for one strike

N/A< 5 nJ for 3kA 8/20 µs waveform

DIN Female DIN Male TSX-DFM

TUSX-DFF 300 MHz to 1.4 GHz 1 kW @ 920 MHz ≤ 0.1 dB < 1.1:1 over frequency range N/A

30 kA per IEC 61000-4-5 8/20 µs waveform for multiple strikes / 40 kA per IEC 61000-4-5 8/20 µs waveform for one strike

N/A< 5 nJ for 3kA 8/20 µs waveform

DIN Female DIN Female TUSX-DFF

TUSX-DFM 300 MHz to 1.4 GHz 1 kW @ 920 MHz ≤ 0.1 dB < 1.1:1 over frequency range N/A

30 kA per IEC 61000-4-5 8/20 µs waveform for multiple strikes / 40 kA per IEC 61000-4-5 8/20 µs waveform for one strike

N/A< 5 nJ for 3kA 8/20 µs waveform

DIN Female DIN Male TUSX-DFM

Page 10: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Coaxial RF Surge Protection10

• Ultra low PIM <-155 dBc 2 x 20 W

• Weather proof when installed

• 50 Ω impedance

• RoHS compliant

Features

• IEC 60529 IP67

• AISG compliant

Standards and Certificates

DAS-P-DFM30

Humidity 95% non-condensing

Operating/Storage Temperature -55°C to +85°C

DAS-P-DFM30

The DAS-P series is a dual band DC pass RF protector that offers outstanding throughput energy of <50V, while providing ultra PIM protection in a 30V unit.

Ultra Low PIM

DAS-P Series

Environmental

Page 11: Protection Technology Group USA_CATALOG_2011-2012

11

DAS-P-DMF30

DAS-P-DFF30

Page 12: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Coaxial RF Surge Protection12

Ultra Low PIM - DAS-P Series

Frequency Range RF Power Insertion Loss VSWR PIM PerformanceMax Continuous Operating Current

Max Surge Current Surge Side Connector Protected Side Connector

DAS-P-DFF30

680 MHz to 1 GHz, 1.7 GHz to 2.3 GHz RF2.0 MHz to 2.5 MHz Telemetry(AISG)

1.5 kW @ 920 MHz<0.1 dB @ 680 MHz to 1 GHz,<0.1 dB @ 1.7 GHz to 2.3 GHz<0.4 dB @ 2.176 MHz

≤1.2:1 @ 680 MHz to 1 GHz,≤1.2:1 @ 1.7 GHz to 2.3 GHz,≤1.4:1 @ 2.176 MHz

<-155 dBc 2 x 20 W 4 A

20 kA per IEC 61000-4-5 8/20 µs waveform for multiple strikes / 30 kA per IEC 61000-4-5 8/20 µs waveform for one strike

DIN Female DIN Female DAS-P-DFF30

DAS-P-DFM30

680 MHz to 1 GHz,1.7 GHz to 2.3 GHz RF2.0 MHz to 2.5 MHz Telemetry(AISG)

1.5 kW @ 920 MHz<0.1 dB @ 680 MHz to 1 GHz,<0.1 dB @ 1.7 GHz to 2.3 GHz<0.4 dB @ 2.176 MHz

≤1.2:1 @ 680 MHz to 1 GHz,≤1.2:1 @ 1.7 GHz to 2.3 GHz,≤1.4:1 @ 2.176 MHz

<-155 dBc 2 x 20 W 4 A

20 kA per IEC 61000-4-5 8/20 µs waveform for multiple strikes / 30 kA per IEC 61000-4-5 8/20 µs waveform for one strike

DIN Female DIN Male DAS-P-DFM30

DAS-P-DMF30

680 MHz to 1 GHz,1.7 GHz to 2.3 GHz RF2.0 MHz to 2.5 MHz Telemetry(AISG)

1.5 kW @ 920 MHz<0.1 dB @ 680 MHz to 1 GHz,<0.1 dB @ 1.7 GHz to 2.3 GHz<0.4 dB @ 2.176 MHz

≤1.2:1 @ 680 MHz to 1 GHz,≤1.2:1 @ 1.7 GHz to 2.3 GHz,≤1.4:1 @ 2.176 MHz

<-155 dBc 2 x 20 W 4 A

20 kA per IEC 61000-4-5 8/20 µs waveform for multiple strikes / 30 kA per IEC 61000-4-5 8/20 µs waveform for one strike

DIN Male DIN Female DAS-P-DMF30

DGXJ-P-DFM-30680 MHz to 1 GHz,1.7 GHz to 2.3 GHz RF

1.5 kW @ 920 MHz<0.1 dB @ 680 MHz to 1 GHz,<0.1 dB @ 1.7 GHz to 2.3 GHz

≤1.2:1 @ 680 MHz to 1 GHz,≤1.2:1 @ 1.7 GHz to 2.3 GHz,

<-155 dBc 2 x 20 W N/A

20 kA per IEC 61000-4-5 8/20 µs waveform for multiple strikes / 30 kA per IEC 61000-4-5 8/20 µs waveform for one strike

DIN Female DIN Male DGXJ-P-DFM-30

Page 13: Protection Technology Group USA_CATALOG_2011-2012

13

Frequency Range RF Power Insertion Loss VSWR PIM PerformanceMax Continuous Operating Current

Max Surge Current Surge Side Connector Protected Side Connector

DAS-P-DFF30

680 MHz to 1 GHz, 1.7 GHz to 2.3 GHz RF2.0 MHz to 2.5 MHz Telemetry(AISG)

1.5 kW @ 920 MHz<0.1 dB @ 680 MHz to 1 GHz,<0.1 dB @ 1.7 GHz to 2.3 GHz<0.4 dB @ 2.176 MHz

≤1.2:1 @ 680 MHz to 1 GHz,≤1.2:1 @ 1.7 GHz to 2.3 GHz,≤1.4:1 @ 2.176 MHz

<-155 dBc 2 x 20 W 4 A

20 kA per IEC 61000-4-5 8/20 µs waveform for multiple strikes / 30 kA per IEC 61000-4-5 8/20 µs waveform for one strike

DIN Female DIN Female DAS-P-DFF30

DAS-P-DFM30

680 MHz to 1 GHz,1.7 GHz to 2.3 GHz RF2.0 MHz to 2.5 MHz Telemetry(AISG)

1.5 kW @ 920 MHz<0.1 dB @ 680 MHz to 1 GHz,<0.1 dB @ 1.7 GHz to 2.3 GHz<0.4 dB @ 2.176 MHz

≤1.2:1 @ 680 MHz to 1 GHz,≤1.2:1 @ 1.7 GHz to 2.3 GHz,≤1.4:1 @ 2.176 MHz

<-155 dBc 2 x 20 W 4 A

20 kA per IEC 61000-4-5 8/20 µs waveform for multiple strikes / 30 kA per IEC 61000-4-5 8/20 µs waveform for one strike

DIN Female DIN Male DAS-P-DFM30

DAS-P-DMF30

680 MHz to 1 GHz,1.7 GHz to 2.3 GHz RF2.0 MHz to 2.5 MHz Telemetry(AISG)

1.5 kW @ 920 MHz<0.1 dB @ 680 MHz to 1 GHz,<0.1 dB @ 1.7 GHz to 2.3 GHz<0.4 dB @ 2.176 MHz

≤1.2:1 @ 680 MHz to 1 GHz,≤1.2:1 @ 1.7 GHz to 2.3 GHz,≤1.4:1 @ 2.176 MHz

<-155 dBc 2 x 20 W 4 A

20 kA per IEC 61000-4-5 8/20 µs waveform for multiple strikes / 30 kA per IEC 61000-4-5 8/20 µs waveform for one strike

DIN Male DIN Female DAS-P-DMF30

DGXJ-P-DFM-30680 MHz to 1 GHz,1.7 GHz to 2.3 GHz RF

1.5 kW @ 920 MHz<0.1 dB @ 680 MHz to 1 GHz,<0.1 dB @ 1.7 GHz to 2.3 GHz

≤1.2:1 @ 680 MHz to 1 GHz,≤1.2:1 @ 1.7 GHz to 2.3 GHz,

<-155 dBc 2 x 20 W N/A

20 kA per IEC 61000-4-5 8/20 µs waveform for multiple strikes / 30 kA per IEC 61000-4-5 8/20 µs waveform for one strike

DIN Female DIN Male DGXJ-P-DFM-30

Page 14: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Coaxial RF Surge Protection14

• Frequency range 1.5 - 1000 MHz

• Insertion loss: 0.1dB

• Ideal for HF, UHF, VHF radios

• DC blocked gas tube design

• No DC continuity between center pins

• Multi-strike capability

Features

• RoHS compliant

Standards and Certificates

IS-B50LN-C2

Operating Temperature -45°C to +50°C

Vibration 1 G up to 100 Hz

IS-B50LN-C2

DC blocked 50 ohm bulkhead mounted protector is ideal for two way radio and SCADA applications.

DC Block

B50 Series

Environmental

Page 15: Protection Technology Group USA_CATALOG_2011-2012

15

IS-B50HN-C0

IS-B50LN-C1

Page 16: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Coaxial RF Surge Protection16

Frequency Range RF Power Insertion Loss VSWR Max Surge Current Turn on Voltage Turn on Time Throughput EnergySurge Side Connector

Protected Side Connector

IS-B50HN-C0 1.5 MHz to 400 MHz VHF 500 W, UHF 250 W, HF 3 kW ≤ 0.1 dB ≤ 1.1 to 1 @ 2 MHz to 400 MHz50 kA per IEC1000-4-5 8/20 µs waveform

±1200 Vdc ± 20 % 7 ns for 2 kV / ns< 20 mJ for 3kA, 8/20 µs waveform

N Female N Female IS-B50HN-C0

IS-B50HN-C1 50 MHz to 700 MHz VHF 500 W, UHF 250 W ≤ 0.1 dB ≤ 1.1 to 1 @ 60 MHz to 700 MHz50 kA per IEC 61000-4-5 8/20 µs waveform

±1200 Vdc ± 20 % 7 ns for 2 kV / ns< 1 mJ for 3kA, 8/20 µs waveform

N Female N Female IS-B50HN-C1

IS-B50HN-C2 125 MHz to 1000 MHz VHF 500 W, UHF 250 W ≤ 0.1 dB ≤ 1.1 to 1 over frequency range50 kA per IEC 61000-4-5 8/20 µs waveform

±1200 Vdc ± 20 % 7 ns for 2 kV / ns< 800 µJ for 3kA, 8/20 µs waveform

N Female N Female IS-B50HN-C2

IS-B50HU-C0 1.5 MHz to 400 MHz HF 3 kW, VHF 500 W, UHF 250 W ≤ 0.1 dB ≤ 1.2 to 1 over frequency range50 kA per IEC 61000-4-5 8/20 µs waveform

±1200 Vdc ± 20 % 7 ns for 2 kV / ns< 20 mJ for 3kA, 8/20 µs waveform

UHF Female UHF Female IS-B50HU-C0

IS-B50HU-C1 50 MHz to 700 MHz VHF 500 W, UHF 250 W ≤ 0.1 dB ≤ 1.2 to 1 over frequency range50 kA per IEC1000-4-5 8/20 µs waveform

±1200 Vdc ± 20 % 7 ns for 2 kV / ns< 1 mJ for 3kA, 8/20 µs waveform

UHF Female UHF Female IS-B50HU-C1

IS-B50LN-C0 1.5 MHz to 400 MHz HF 2 kW, VHF 375 W, UHF 125 W ≤ 0.1 dB ≤ 1.1 to 1 @ 2 MHz to 400 MHz50 kA per IEC 61000-4-5 8/20 µs waveform

±600 Vdc ± 20 % 2.5 ns for 2 kV / ns< 10 mJ for 3 kA, 8/20 µs waveform

N Female N Female IS-B50LN-C0

IS-B50LN-C1 50 MHz to 700 MHz VHF 375 W, UHF 125 W ≤ 0.1 dB ≤ 1.1 to 1 @ 60 MHz to 700 MHz50 kA per IEC 61000-4-5 8/20 µs waveform

±600 Vdc ± 20 % 2.5 ns for 2 kV / ns< 600 µJ for 3kA, 8/20 µs waveform

N Female N Female IS-B50LN-C1

IS-B50LN-C2 125 MHz to 1 GHz VHF 375 W, UHF 125 to 50 W ≤ 0.1 dB ≤ 1.1 to 1 over frequency range50 kA per IEC 61000-4-5 8/20 µs waveform

600 Vdc ± 20 % 2.5 ns for 2 kV / ns< 220 µJ for 3kA, 8/20 µs waveform

N Female N Female IS-B50LN-C2

IS-B50LU-C0 1.5 MHz to 400 MHz HF 2 kW, VHF 375 W, UHF 125 W ≤ 0.1 dB ≤ 1.2 to 1 over frequency range50 kA per IEC1000-4-5 8/20 µs waveform

±600 Vdc ± 20 % 2.5 ns for 2 kV / ns< 10 mJ for 3kA, 8/20 µs waveform

UHF Female UHF Female IS-B50LU-C0

IS-B50LU-C1 50 MHz to 700 MHz VHF 375 W, UHF 125 W ≤ 0.1 dB ≤ 1.2 to 1 over frequency range50 kA per IEC 61000-4-5 8/20 µs waveform

±600 Vdc ± 20 % 2.5 ns for 2 kV / ns< 600 µJ for 3 kA, 8/20 µs waveform

UHF Female UHF Female IS-B50LU-C1

DC Block - B50 Series

Page 17: Protection Technology Group USA_CATALOG_2011-2012

17

Frequency Range RF Power Insertion Loss VSWR Max Surge Current Turn on Voltage Turn on Time Throughput EnergySurge Side Connector

Protected Side Connector

IS-B50HN-C0 1.5 MHz to 400 MHz VHF 500 W, UHF 250 W, HF 3 kW ≤ 0.1 dB ≤ 1.1 to 1 @ 2 MHz to 400 MHz50 kA per IEC1000-4-5 8/20 µs waveform

±1200 Vdc ± 20 % 7 ns for 2 kV / ns< 20 mJ for 3kA, 8/20 µs waveform

N Female N Female IS-B50HN-C0

IS-B50HN-C1 50 MHz to 700 MHz VHF 500 W, UHF 250 W ≤ 0.1 dB ≤ 1.1 to 1 @ 60 MHz to 700 MHz50 kA per IEC 61000-4-5 8/20 µs waveform

±1200 Vdc ± 20 % 7 ns for 2 kV / ns< 1 mJ for 3kA, 8/20 µs waveform

N Female N Female IS-B50HN-C1

IS-B50HN-C2 125 MHz to 1000 MHz VHF 500 W, UHF 250 W ≤ 0.1 dB ≤ 1.1 to 1 over frequency range50 kA per IEC 61000-4-5 8/20 µs waveform

±1200 Vdc ± 20 % 7 ns for 2 kV / ns< 800 µJ for 3kA, 8/20 µs waveform

N Female N Female IS-B50HN-C2

IS-B50HU-C0 1.5 MHz to 400 MHz HF 3 kW, VHF 500 W, UHF 250 W ≤ 0.1 dB ≤ 1.2 to 1 over frequency range50 kA per IEC 61000-4-5 8/20 µs waveform

±1200 Vdc ± 20 % 7 ns for 2 kV / ns< 20 mJ for 3kA, 8/20 µs waveform

UHF Female UHF Female IS-B50HU-C0

IS-B50HU-C1 50 MHz to 700 MHz VHF 500 W, UHF 250 W ≤ 0.1 dB ≤ 1.2 to 1 over frequency range50 kA per IEC1000-4-5 8/20 µs waveform

±1200 Vdc ± 20 % 7 ns for 2 kV / ns< 1 mJ for 3kA, 8/20 µs waveform

UHF Female UHF Female IS-B50HU-C1

IS-B50LN-C0 1.5 MHz to 400 MHz HF 2 kW, VHF 375 W, UHF 125 W ≤ 0.1 dB ≤ 1.1 to 1 @ 2 MHz to 400 MHz50 kA per IEC 61000-4-5 8/20 µs waveform

±600 Vdc ± 20 % 2.5 ns for 2 kV / ns< 10 mJ for 3 kA, 8/20 µs waveform

N Female N Female IS-B50LN-C0

IS-B50LN-C1 50 MHz to 700 MHz VHF 375 W, UHF 125 W ≤ 0.1 dB ≤ 1.1 to 1 @ 60 MHz to 700 MHz50 kA per IEC 61000-4-5 8/20 µs waveform

±600 Vdc ± 20 % 2.5 ns for 2 kV / ns< 600 µJ for 3kA, 8/20 µs waveform

N Female N Female IS-B50LN-C1

IS-B50LN-C2 125 MHz to 1 GHz VHF 375 W, UHF 125 to 50 W ≤ 0.1 dB ≤ 1.1 to 1 over frequency range50 kA per IEC 61000-4-5 8/20 µs waveform

600 Vdc ± 20 % 2.5 ns for 2 kV / ns< 220 µJ for 3kA, 8/20 µs waveform

N Female N Female IS-B50LN-C2

IS-B50LU-C0 1.5 MHz to 400 MHz HF 2 kW, VHF 375 W, UHF 125 W ≤ 0.1 dB ≤ 1.2 to 1 over frequency range50 kA per IEC1000-4-5 8/20 µs waveform

±600 Vdc ± 20 % 2.5 ns for 2 kV / ns< 10 mJ for 3kA, 8/20 µs waveform

UHF Female UHF Female IS-B50LU-C0

IS-B50LU-C1 50 MHz to 700 MHz VHF 375 W, UHF 125 W ≤ 0.1 dB ≤ 1.2 to 1 over frequency range50 kA per IEC 61000-4-5 8/20 µs waveform

±600 Vdc ± 20 % 2.5 ns for 2 kV / ns< 600 µJ for 3 kA, 8/20 µs waveform

UHF Female UHF Female IS-B50LU-C1

Page 18: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Coaxial RF Surge Protection18

• High surge current capability

• Low let-through voltage and throughput energy

• DC shorted filter design, no DC continuity between center pins

• Ideal use for applications where DC is not required on the coaxial cable

• Fully weatherized housing

• Elongated female connector allows for mounting through a 1/4” bulkhead or grounding bar

• Multi-strike capability

Features

• IEC 60529 IP65

• Bellcore # TA-NWT-00487

• Procedure 4.11, wind driven

• UL 497B

• RoHS compliant

Standards and Certificates

DSXL

Humidity 100% condensing

Operating/Storage Temperature -40°C to +85°C

Vibration 1 G @ 5 Hz to 100 HzDSXL Series

Patented SX radio frequency DC blocked filter protectors are ideal for RF coaxial applications where DC is not required. The SX can be used on high-powered RF feeder lines in the range of 350 to 2,300 MHz, as well as low-powered microwave sites at 2 to 10 GHz. The SX is available in a multitude of connector configurations each exhibiting low return loss, insertion loss and let-through voltage.

DC Block

SX Series

Environmental

Page 19: Protection Technology Group USA_CATALOG_2011-2012

19

AL-LSXM

DSXL-D-MA

Page 20: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Coaxial RF Surge Protection20

Frequency Range VSWR RF Power Insertion Loss PIM Performance Max Surge Current Throughput EnergySurge Side Connector

Protected Side Connector

AL-LSXM 2.0 GHz to 6.0 GHz < 1.2 to 1 over frequency range 10 W< 0.1 dB Typical (< 0.2 dB Max)

N/A 10 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform N Female N Female AL-LSXM

AL-LSXM-MA 2.0 GHz to 6.0 GHz < 1.2 to 1 over frequency range 10 W< 0.1 dB Typical (< 0.2 dB Max)

N/A 10 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform N Male N Female AL-LSXM-MA

WSXM 6.0 GHz to 10.0 GHz < 1.2 to 1 over frequency range 10 W < 0.1 dB N/A 10 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform N Female N Female WSXM

DSXL800 MHz to 2.3 GHz700 MHz to 2.7 GHz

< 1.1 to 1 over frequency range< 1.2 to 1 over frequency range

750 W @ 40º C, 1 kW @ 20º C, 500 W @ 85º C

< 0.1 dB N/A 20 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform N Female N Female DSXL

DSXL-D800 MHz to 2.3 GHz700 MHz to 2.5 GHz

< 1.1 to 1 over frequency range< 1.2 to 1 over frequency range

750 W @ 40º C, 1 kW @ 20º C, 500 W @ 85º C

< 0.1 dB N/A 30 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform DIN Female DIN Female DSXL-D

DSXL-D-MA800 MHz to 2.3 GHz700 MHz to 2.5 GHz

< 1.1 to 1 over frequency range< 1.2 to 1 over frequency range

750 W @ 40º C, 1 kW @ 20º C, 500 W @ 85º C

< 0.1 dB N/A 30 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform DIN Male DIN Female DSXL-D-MA

DSXL-D-MA-BF800 MHz to 2.3 GHz700 MHz to 2.5 GHz

< 1.1 to 1 over frequency range< 1.2 to 1 over frequency range

750 W @ 40º C, 1 kW @ 20º C, 500 W @ 85º C

< 0.1 dB N/A 30 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform DIN Male DIN Female DSXL-D-MA-BF

DSXL-D-MA-P2-BF800 MHz to 2.3 GHz700 MHz to 2.5 GHz

< 1.1 to 1 over frequency range< 1.2 to 1 over frequency range

750 W @ 40º C, 1 kW @ 20º C, 500 W @ 85º C

< 0.1 dB -120 dBm 30 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform DIN Male DIN Female DSXL-D-MA-P2-BF

DSXL-D-ME800 MHz to 2.3 GHz700 MHz to 2.5 GHz

< 1.1 to 1 over frequency range< 1.2 to 1 over frequency range

750 W @ 40º C, 1 kW @ 20º C, 500 W @ 85º C

< 0.1 dB N/A 30 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform DIN Female DIN Male DSXL-D-ME

DSXL-D-SP800 MHz to 2.3 GHz700 MHz to 2.5 GHz

< 1.1 to 1 over frequency range< 1.2 to 1 over frequency range

500 W @ 85º C, 750 W @ 40º C, 1 kW @ 20º C

< 0.1 dB N/A 30 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform DIN Female DIN Female DSXL-D-SP

DSXL-DN-MA800 MHz to 2.3 GHz700 MHz to 2.5 GHz

< 1.1 to 1 over frequency range< 1.2 to 1 over frequency range

500 W @ 85º C, 700 W @ 40º C, 1 kW @ 20º C

< 0.1 dB N/A 30 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform DIN Male N Female DSXL-DN-MA

DSXL-MA800 MHz to 2.3 GHz700 MHz to 2.7 GHz

< 1.1 to 1 over frequency range< 1.2 to 1 over frequency range

750 W @ 50º C, 500 W @ 920º MHz

< 0.1 dB N/A 20 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform N Male N Female DSXL-MA

DSXL-MA-SP800 MHz to 2.0 GHz800 MHz to 2.3 GHz700 MHz to 2.7 GHz

< 1.1 to 1 over frequency range< 1.1 to 1 over frequency range< 1.2 to 1 over frequency range

750 W @ 50º C, 500 W @ 920º MHz

< 0.1 dB N/A 20 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform N Male N Female DSXL-MA-SP

DSXL-MA-BF800 MHz to 2.3 GHz700 MHz to 2.7 GHz

< 1.1 to 1 over frequency range< 1.2 to 1 over frequency range

750 W @ 50º C, 500 W @ 920º MHz

< 0.1 dB N/A 20 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform N Male N Female DSXL-MA-BF

DSXL-ME800 MHz to 2.3 GHz700 MHz to 2.7 GHz

< 1.1 to 1 over frequency range< 1.2 to 1 over frequency range

750 W @ 50º C, 500 W @ 920º MHz

< 0.1 dB N/A 20 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform N Female N Male DSXL-ME

DSXL-P800 MHz to 2.3 GHz700 MHz to 2.7 GHz

< 1.1 to 1 over frequency range< 1.2 to 1 over frequency range

750 W @ 50º C, 500 W @ 920º MHz

< 0.1 dB -110 dBm 20 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform N Female N Female DSXL-P

DC Block - SX Series

Page 21: Protection Technology Group USA_CATALOG_2011-2012

21

Frequency Range VSWR RF Power Insertion Loss PIM Performance Max Surge Current Throughput EnergySurge Side Connector

Protected Side Connector

AL-LSXM 2.0 GHz to 6.0 GHz < 1.2 to 1 over frequency range 10 W< 0.1 dB Typical (< 0.2 dB Max)

N/A 10 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform N Female N Female AL-LSXM

AL-LSXM-MA 2.0 GHz to 6.0 GHz < 1.2 to 1 over frequency range 10 W< 0.1 dB Typical (< 0.2 dB Max)

N/A 10 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform N Male N Female AL-LSXM-MA

WSXM 6.0 GHz to 10.0 GHz < 1.2 to 1 over frequency range 10 W < 0.1 dB N/A 10 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform N Female N Female WSXM

DSXL800 MHz to 2.3 GHz700 MHz to 2.7 GHz

< 1.1 to 1 over frequency range< 1.2 to 1 over frequency range

750 W @ 40º C, 1 kW @ 20º C, 500 W @ 85º C

< 0.1 dB N/A 20 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform N Female N Female DSXL

DSXL-D800 MHz to 2.3 GHz700 MHz to 2.5 GHz

< 1.1 to 1 over frequency range< 1.2 to 1 over frequency range

750 W @ 40º C, 1 kW @ 20º C, 500 W @ 85º C

< 0.1 dB N/A 30 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform DIN Female DIN Female DSXL-D

DSXL-D-MA800 MHz to 2.3 GHz700 MHz to 2.5 GHz

< 1.1 to 1 over frequency range< 1.2 to 1 over frequency range

750 W @ 40º C, 1 kW @ 20º C, 500 W @ 85º C

< 0.1 dB N/A 30 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform DIN Male DIN Female DSXL-D-MA

DSXL-D-MA-BF800 MHz to 2.3 GHz700 MHz to 2.5 GHz

< 1.1 to 1 over frequency range< 1.2 to 1 over frequency range

750 W @ 40º C, 1 kW @ 20º C, 500 W @ 85º C

< 0.1 dB N/A 30 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform DIN Male DIN Female DSXL-D-MA-BF

DSXL-D-MA-P2-BF800 MHz to 2.3 GHz700 MHz to 2.5 GHz

< 1.1 to 1 over frequency range< 1.2 to 1 over frequency range

750 W @ 40º C, 1 kW @ 20º C, 500 W @ 85º C

< 0.1 dB -120 dBm 30 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform DIN Male DIN Female DSXL-D-MA-P2-BF

DSXL-D-ME800 MHz to 2.3 GHz700 MHz to 2.5 GHz

< 1.1 to 1 over frequency range< 1.2 to 1 over frequency range

750 W @ 40º C, 1 kW @ 20º C, 500 W @ 85º C

< 0.1 dB N/A 30 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform DIN Female DIN Male DSXL-D-ME

DSXL-D-SP800 MHz to 2.3 GHz700 MHz to 2.5 GHz

< 1.1 to 1 over frequency range< 1.2 to 1 over frequency range

500 W @ 85º C, 750 W @ 40º C, 1 kW @ 20º C

< 0.1 dB N/A 30 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform DIN Female DIN Female DSXL-D-SP

DSXL-DN-MA800 MHz to 2.3 GHz700 MHz to 2.5 GHz

< 1.1 to 1 over frequency range< 1.2 to 1 over frequency range

500 W @ 85º C, 700 W @ 40º C, 1 kW @ 20º C

< 0.1 dB N/A 30 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform DIN Male N Female DSXL-DN-MA

DSXL-MA800 MHz to 2.3 GHz700 MHz to 2.7 GHz

< 1.1 to 1 over frequency range< 1.2 to 1 over frequency range

750 W @ 50º C, 500 W @ 920º MHz

< 0.1 dB N/A 20 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform N Male N Female DSXL-MA

DSXL-MA-SP800 MHz to 2.0 GHz800 MHz to 2.3 GHz700 MHz to 2.7 GHz

< 1.1 to 1 over frequency range< 1.1 to 1 over frequency range< 1.2 to 1 over frequency range

750 W @ 50º C, 500 W @ 920º MHz

< 0.1 dB N/A 20 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform N Male N Female DSXL-MA-SP

DSXL-MA-BF800 MHz to 2.3 GHz700 MHz to 2.7 GHz

< 1.1 to 1 over frequency range< 1.2 to 1 over frequency range

750 W @ 50º C, 500 W @ 920º MHz

< 0.1 dB N/A 20 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform N Male N Female DSXL-MA-BF

DSXL-ME800 MHz to 2.3 GHz700 MHz to 2.7 GHz

< 1.1 to 1 over frequency range< 1.2 to 1 over frequency range

750 W @ 50º C, 500 W @ 920º MHz

< 0.1 dB N/A 20 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform N Female N Male DSXL-ME

DSXL-P800 MHz to 2.3 GHz700 MHz to 2.7 GHz

< 1.1 to 1 over frequency range< 1.2 to 1 over frequency range

750 W @ 50º C, 500 W @ 920º MHz

< 0.1 dB -110 dBm 20 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform N Female N Female DSXL-P

Page 22: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Coaxial RF Surge Protection22

Frequency Range VSWR RF Power Insertion Loss PIM Performance Max Surge Current Throughput EnergySurge Side Connector

Protected Side Connector

PSXL 1.2 GHz to 2.8 GHz < 1.1 to 1 over frequency range 300 W < 0.1dB N/A 20 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform N Female N Female PSXL

LSXL1.8 GHz to 3.8 GHz 4.2 GHz to 6.0 GHz

< 1.2 to 1 over frequency range 10 W < 0.2dB N/A 18 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform N Female N Female LSXL

LSXL-ME1.8 GHz to 3.8 GHz 4.2 GHz to 6.0 GHz

< 1.2 to 1 over frequency range 10 W < 0.2dB N/A 18 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform N Female N Male LSXL-ME

USXL-D350 MHz to 1.2 GHz

< 1.1 to 1 over frequency range1 kW @ 85 °C @ 450 MHz,2 kW @ 20 °C @ 450 MHz

< 0.1dB N/A 25 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform DIN Female DIN Female USXL-D

DC Block - SX Series

Page 23: Protection Technology Group USA_CATALOG_2011-2012

23

Frequency Range VSWR RF Power Insertion Loss PIM Performance Max Surge Current Throughput EnergySurge Side Connector

Protected Side Connector

PSXL 1.2 GHz to 2.8 GHz < 1.1 to 1 over frequency range 300 W < 0.1dB N/A 20 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform N Female N Female PSXL

LSXL1.8 GHz to 3.8 GHz 4.2 GHz to 6.0 GHz

< 1.2 to 1 over frequency range 10 W < 0.2dB N/A 18 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform N Female N Female LSXL

LSXL-ME1.8 GHz to 3.8 GHz 4.2 GHz to 6.0 GHz

< 1.2 to 1 over frequency range 10 W < 0.2dB N/A 18 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform N Female N Male LSXL-ME

USXL-D350 MHz to 1.2 GHz

< 1.1 to 1 over frequency range1 kW @ 85 °C @ 450 MHz,2 kW @ 20 °C @ 450 MHz

< 0.1dB N/A 25 kA per IEC 61000-4-5 8/20 µs waveform < 0.5 µJ for 3 kA, 8/20 µs waveform DIN Female DIN Female USXL-D

Page 24: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Coaxial RF Surge Protection24

• Multi-strike capability

• Low throughput energy

• Mount to bracket or flat single point grounding panel

• Flange and bulkhead mounting options

Features

• RoHS compliant

Standards and Certificates

IS-50NX-C1-ME

Operating Temperature -45°C to +50°C

Vibration 1 G up to 100 Hz

IS-50NX-CO

The IS-50 series is a DC block broadband HF/VHF/UHF coaxial protector that operates in the frequency range of 1.5 to 1000 MHz.

DC Block

IS-50 Series

Environmental

Page 25: Protection Technology Group USA_CATALOG_2011-2012

25

IS-50NX-C0

IS-50NX-C0-MA

Page 26: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Coaxial RF Surge Protection26

Frequency Range RF Power Insertion Loss VSWR Max Surge Current Turn on Voltage Turn on Time Throughput EnergySurge Side Connector

Protected Side Connector

IS-50NX-C0 1.5 MHz to 400 MHzHF 2 kW, VHF 375 W, UHF 125 W

≤ 0.1 dB≤1.1 to 1 for 2 to 400 MHz

50 kA per IEC 1000-4-5 8/20 µs waveform 500 J

600 Vdc ± 20 % 2.5 ns for 2 kV/ns≤ 10 mJ 6 kV / 3 kA, 8/20 µs waveform

N Female N Female IS-50NX-C0

IS-50NX-C0-MA 1.5 MHz to 400 MHzHF 2 kW, VHF 375 W, UHF 125 W

≤ 0.1 dB≤1.1 to 1 for 2 to 400 MHz

50 kA per IEC 1000-4-5 8/20 µs waveform 500 J

600 Vdc ± 20 % 2.5 ns for 2 kV/ns≤ 10 mJ 6 kV / 3 kA, 8/20 µs waveform

N Male N Female IS-50NX-C0-MA

IS-50NX-C0-ME 1.5 MHz to 400 MHzHF 2 kW, VHF 375 W, UHF 125 W

≤ 0.1 dB≤1.1 to 1 for 2 to 400 MHz

50 kA per IEC 1000-4-5 8/20 µs waveform 500 J

600 Vdc ± 20 % 2.5 ns for 2 kV/ns≤ 10 mJ 6 kV / 3 kA, 8/20 µs waveform

N Female N Male IS-50NX-C0-ME

IS-50NX-C1 50 MHz to 700 MHz VHF 375 W, UHF 125 W ≤ 0.1 dB≤1.1 to 1 for 60 to 700 MHz

50 kA per IEC 1000-4-5 8/20 µs waveform 500 J

600 Vdc ± 20 % 2.5 ns for 2 kV/ns≤ 600 µJ for 3 kA, 8/20 µs waveform

N Female N Female IS-50NX-C1

IS-50NX-C1-MA 50 MHz to 700 MHz VHF 375 W, UHF 125 W ≤ 0.1 dB≤1.1 to 1 for 60 to 700 MHz

50 kA per IEC 1000-4-5 8/20 µs waveform 500 J

600 Vdc ± 20 % 2.5 ns for 2 kV/ns≤ 600 µJ for 3 kA, 8/20 µs waveform

N Male N Female IS-50NX-C1-MA

IS-50NX-C1-ME 50 MHz to 700 MHz VHF 375 W, UHF 125 W ≤ 0.1 dB≤1.1 to 1 for 60 to 700 MHz

50 kA per IEC 1000-4-5 8/20 µs waveform 500 J

600 Vdc ± 20 % 2.5 ns for 2 kV/ns≤ 600 µJ for 3 kA, 8/20 µs waveform

N Female N Male IS-50NX-C1-ME

IS-50NX-C2 125 MHz to 1 GHz125 to 220 MHz @ 375 W, 220 to 700 MHz @ 125 W, 700 to 1000 MHz @ 50 W

≤ 0.1 dB≤1.1 to 1 over frequency range

50 kA per IEC 1000-4-5 8/20 µs waveform 500 J

600 Vdc ± 20 % 2.5 ns for 2 kV/ns≤ 220 µJ for 3 kA, 8/20 µs waveform

N Female N Female IS-50NX-C2

IS-50NX-C2-MA 125 MHz to 1 GHz125 to 220 MHz @ 375 W, 220 to 700 MHz @ 125 W, 700 to 1000 MHz @ 50 W

≤ 0.1 dB≤1.1 to 1 over frequency range

50 kA per IEC 1000-4-5 8/20 µs waveform 500 J

600 Vdc ± 20 % 2.5 ns for 2 kV/ns≤ 220 µJ for 3 kA, 8/20 µs waveform

N Male N Female IS-50NX-C2-MA

IS-50NX-C2-ME 125 MHz to 1 GHz125 to 220 MHz @ 375 W, 220 to 700 MHz @ 125 W, 700 to 1000 MHz @ 50 W

≤ 0.1 dB≤1.1 to 1 over frequency range

50 kA per IEC 1000-4-5 8/20 µs waveform 500 J

600 Vdc ± 20 % 2.5 ns for 2 kV/ns≤ 220 µJ for 3 kA, 8/20 µs waveform

N Female N Male IS-50NX-C2-ME

IS-50UX-C0 1.5 MHz to 400 MHzHF 2 kW, VHF 375 W, UHF 125 W

≤ 0.1 dB≤1.2 to 1 over frequency range

50 kA per IEC 1000-4-5 8/20 µs waveform 500 J

600 Vdc ± 20 % 2.5 ns for 2 kV/ns≤ 10 mJ for 3 kA, 8/20 µs waveform

UHF Female UHF Female IS-50UX-C0

IS-50UX-C0-MA 1.5 MHz to 400 MHzHF 2 kW, VHF 375 W, UHF 125 W

≤ 0.1 dB≤1.2 to 1 over frequency range

50 kA per IEC 1000-4-5 8/20 µs waveform 500 J

600 Vdc ± 20 % 2.5 ns for 2 kV/ns≤ 10 mJ for 3 kA, 8/20 µs waveform

UHF Male UHF Female IS-50UX-C0-MA

IS-50UX-C0-ME 1.5 MHz to 400 MHzHF 2 kW, VHF 375 W, UHF 125 W

≤ 0.1 dB≤1.2 to 1 over frequency range

50 kA per IEC 1000-4-5 8/20 µs waveform 500 J

600 Vdc ± 20 % 2.5 ns for 2 kV/ns≤ 10 mJ for 3 kA, 8/20 µs waveform

UHF Female UHF Male IS-50UX-C0-ME

IS-50UX-C1 50 MHz to 700 MHzVHF 375 W, UHF 125 W

≤ 0.1 dB≤1.2 to 1 over frequency range

50 kA per IEC 1000-4-5 8/20 µs waveform 500 J

600 Vdc ± 20 % 2.5 ns for 2 kV/ns ≤ 600 µJ for 2 kV/ns UHF Female UHF Female IS-50UX-C1

IS-50UX-C1-MA 50 MHz to 700 MHzVHF 375 W, UHF 125 W

≤ 0.1 dB≤1.2 to 1 over frequency range

50 kA per IEC 1000-4-5 8/20 µs waveform 500 J

600 Vdc ± 20 % 2.5 ns for 2 kV/ns ≤ 600 µJ for 2 kV/ns UHF Male UHF Female IS-50UX-C1-MA

IS-50UX-C1-ME 50 MHz to 700 MHzVHF 375 W, UHF 125 W

≤ 0.1 dB≤1.2 to 1 over frequency range

50 kA per IEC 1000-4-5 8/20 µs waveform 500 J

600 Vdc ± 20 % 2.5 ns for 2 kV/ns ≤ 600 µJ for 2 kV/ns UHF Female UHF Male IS-50UX-C1-ME

DC Block - IS-50 Series

Page 27: Protection Technology Group USA_CATALOG_2011-2012

27

Frequency Range RF Power Insertion Loss VSWR Max Surge Current Turn on Voltage Turn on Time Throughput EnergySurge Side Connector

Protected Side Connector

IS-50NX-C0 1.5 MHz to 400 MHzHF 2 kW, VHF 375 W, UHF 125 W

≤ 0.1 dB≤1.1 to 1 for 2 to 400 MHz

50 kA per IEC 1000-4-5 8/20 µs waveform 500 J

600 Vdc ± 20 % 2.5 ns for 2 kV/ns≤ 10 mJ 6 kV / 3 kA, 8/20 µs waveform

N Female N Female IS-50NX-C0

IS-50NX-C0-MA 1.5 MHz to 400 MHzHF 2 kW, VHF 375 W, UHF 125 W

≤ 0.1 dB≤1.1 to 1 for 2 to 400 MHz

50 kA per IEC 1000-4-5 8/20 µs waveform 500 J

600 Vdc ± 20 % 2.5 ns for 2 kV/ns≤ 10 mJ 6 kV / 3 kA, 8/20 µs waveform

N Male N Female IS-50NX-C0-MA

IS-50NX-C0-ME 1.5 MHz to 400 MHzHF 2 kW, VHF 375 W, UHF 125 W

≤ 0.1 dB≤1.1 to 1 for 2 to 400 MHz

50 kA per IEC 1000-4-5 8/20 µs waveform 500 J

600 Vdc ± 20 % 2.5 ns for 2 kV/ns≤ 10 mJ 6 kV / 3 kA, 8/20 µs waveform

N Female N Male IS-50NX-C0-ME

IS-50NX-C1 50 MHz to 700 MHz VHF 375 W, UHF 125 W ≤ 0.1 dB≤1.1 to 1 for 60 to 700 MHz

50 kA per IEC 1000-4-5 8/20 µs waveform 500 J

600 Vdc ± 20 % 2.5 ns for 2 kV/ns≤ 600 µJ for 3 kA, 8/20 µs waveform

N Female N Female IS-50NX-C1

IS-50NX-C1-MA 50 MHz to 700 MHz VHF 375 W, UHF 125 W ≤ 0.1 dB≤1.1 to 1 for 60 to 700 MHz

50 kA per IEC 1000-4-5 8/20 µs waveform 500 J

600 Vdc ± 20 % 2.5 ns for 2 kV/ns≤ 600 µJ for 3 kA, 8/20 µs waveform

N Male N Female IS-50NX-C1-MA

IS-50NX-C1-ME 50 MHz to 700 MHz VHF 375 W, UHF 125 W ≤ 0.1 dB≤1.1 to 1 for 60 to 700 MHz

50 kA per IEC 1000-4-5 8/20 µs waveform 500 J

600 Vdc ± 20 % 2.5 ns for 2 kV/ns≤ 600 µJ for 3 kA, 8/20 µs waveform

N Female N Male IS-50NX-C1-ME

IS-50NX-C2 125 MHz to 1 GHz125 to 220 MHz @ 375 W, 220 to 700 MHz @ 125 W, 700 to 1000 MHz @ 50 W

≤ 0.1 dB≤1.1 to 1 over frequency range

50 kA per IEC 1000-4-5 8/20 µs waveform 500 J

600 Vdc ± 20 % 2.5 ns for 2 kV/ns≤ 220 µJ for 3 kA, 8/20 µs waveform

N Female N Female IS-50NX-C2

IS-50NX-C2-MA 125 MHz to 1 GHz125 to 220 MHz @ 375 W, 220 to 700 MHz @ 125 W, 700 to 1000 MHz @ 50 W

≤ 0.1 dB≤1.1 to 1 over frequency range

50 kA per IEC 1000-4-5 8/20 µs waveform 500 J

600 Vdc ± 20 % 2.5 ns for 2 kV/ns≤ 220 µJ for 3 kA, 8/20 µs waveform

N Male N Female IS-50NX-C2-MA

IS-50NX-C2-ME 125 MHz to 1 GHz125 to 220 MHz @ 375 W, 220 to 700 MHz @ 125 W, 700 to 1000 MHz @ 50 W

≤ 0.1 dB≤1.1 to 1 over frequency range

50 kA per IEC 1000-4-5 8/20 µs waveform 500 J

600 Vdc ± 20 % 2.5 ns for 2 kV/ns≤ 220 µJ for 3 kA, 8/20 µs waveform

N Female N Male IS-50NX-C2-ME

IS-50UX-C0 1.5 MHz to 400 MHzHF 2 kW, VHF 375 W, UHF 125 W

≤ 0.1 dB≤1.2 to 1 over frequency range

50 kA per IEC 1000-4-5 8/20 µs waveform 500 J

600 Vdc ± 20 % 2.5 ns for 2 kV/ns≤ 10 mJ for 3 kA, 8/20 µs waveform

UHF Female UHF Female IS-50UX-C0

IS-50UX-C0-MA 1.5 MHz to 400 MHzHF 2 kW, VHF 375 W, UHF 125 W

≤ 0.1 dB≤1.2 to 1 over frequency range

50 kA per IEC 1000-4-5 8/20 µs waveform 500 J

600 Vdc ± 20 % 2.5 ns for 2 kV/ns≤ 10 mJ for 3 kA, 8/20 µs waveform

UHF Male UHF Female IS-50UX-C0-MA

IS-50UX-C0-ME 1.5 MHz to 400 MHzHF 2 kW, VHF 375 W, UHF 125 W

≤ 0.1 dB≤1.2 to 1 over frequency range

50 kA per IEC 1000-4-5 8/20 µs waveform 500 J

600 Vdc ± 20 % 2.5 ns for 2 kV/ns≤ 10 mJ for 3 kA, 8/20 µs waveform

UHF Female UHF Male IS-50UX-C0-ME

IS-50UX-C1 50 MHz to 700 MHzVHF 375 W, UHF 125 W

≤ 0.1 dB≤1.2 to 1 over frequency range

50 kA per IEC 1000-4-5 8/20 µs waveform 500 J

600 Vdc ± 20 % 2.5 ns for 2 kV/ns ≤ 600 µJ for 2 kV/ns UHF Female UHF Female IS-50UX-C1

IS-50UX-C1-MA 50 MHz to 700 MHzVHF 375 W, UHF 125 W

≤ 0.1 dB≤1.2 to 1 over frequency range

50 kA per IEC 1000-4-5 8/20 µs waveform 500 J

600 Vdc ± 20 % 2.5 ns for 2 kV/ns ≤ 600 µJ for 2 kV/ns UHF Male UHF Female IS-50UX-C1-MA

IS-50UX-C1-ME 50 MHz to 700 MHzVHF 375 W, UHF 125 W

≤ 0.1 dB≤1.2 to 1 over frequency range

50 kA per IEC 1000-4-5 8/20 µs waveform 500 J

600 Vdc ± 20 % 2.5 ns for 2 kV/ns ≤ 600 µJ for 2 kV/ns UHF Female UHF Male IS-50UX-C1-ME

Page 28: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Coaxial RF Surge Protection28

• Low throughput energy

• High surge current capability

• Ultra fast response

• VHF and UHF applications

• Bulkhead mount

Features

• RoHS compliant

Standards and Certificates

IS-NEMP-C0

Operating Temperature -45°C to +50°C

Vibration 1 G @ 5 Hz to 100 Hz

IS-NEMP-C0-MA

Ultra fast NEMP protection for frequency range of 1.5 to 1000 MHz, used in emergency radio communications equipment.

DC Block

NEMP Series

Environmental

Page 29: Protection Technology Group USA_CATALOG_2011-2012

29

IS-NEMP-C1-MA

IS-NEMP-C2-ME

Page 30: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Coaxial RF Surge Protection30

Frequency Range RF Power Insertion Loss VSWR Max Surge Current Turn on Voltage Turn on Time Throughput EnergySurge Side Connector

Protected Side Connector

IS-NEMP-C0 1.5 MHz to 400 MHz 500 W HF, 200 W VHF, 100 W UHF ≤ 0.1dB < 1.1 to 1 @ 2 MHz to 400 MHz50 kA per IEC1000-4-5 8/20 µs waveform 500 J

330 Vdc ± 20% 1.5 ns for 2 kV / ns< 1100 µJ for 8/20 µs waveform

N Female N Female IS-NEMP-C0

IS-NEMP-C0-MA 1.5 MHz to 400 MHz 500 W HF, 200 W VHF, 100 W UHF ≤ 0.1dB < 1.1 to 1 over frequency range50 kA per IEC1000-4-5 8/20 µs waveform 500 J

330 Vdc ± 20% 1.5 ns for 2 kV / ns< 1100 µJ for 8/20 µs waveform

N Male N Female IS-NEMP-C0-MA

IS-NEMP-C0-ME 1.5 MHz to 400 MHz 500 W HF, 200 W VHF, 100 W UHF ≤ 0.1dB < 1.1 to 1 over frequency range50 kA per IEC1000-4-5 8/20 µs waveform 500 J

330 Vdc ± 20% 1.5 ns for 2 kV / ns< 1100 µJ for 8/20 µs waveform

N Female N Male IS-NEMP-C0-ME

IS-NEMP-C1 50 MHz to 700 MHz 200 W VHF, 100 W UHF ≤ 0.1dB < 1.1 to 1 @ 60 MHz to 700 MHz50 kA per IEC1000-4-5 8/20 µs waveform 500 J

330 Vdc ± 20% 1.5 ns for 2 kV / ns< 570 µJ for 8/20 µs waveform

N Female N Female IS-NEMP-C1

IS-NEMP-C1-MA 50 MHz to 700 MHz 200 W VHF, 100 W UHF ≤ 0.1dB < 1.1 to 1 @ 60 MHz to 700 MHz50 kA per IEC1000-4-5 8/20 µs waveform 500 J

330 Vdc ± 20% 1.5 ns for 2 kV / ns< 313 µJ for 8/20 µs waveform

N Male N Female IS-NEMP-C1-MA

IS-NEMP-C1-ME 50 MHz to 700 MHz 200 W VHF, 100 W UHF ≤ 0.1dB < 1.1 to 1 @ 60 MHz to 700 MHz50 kA per IEC1000-4-5 8/20 µs waveform 500 J

330 Vdc ± 20% 1.5 ns for 2 kV / ns< 313 µJ for 8/20 µs waveform

N Female N Male IS-NEMP-C1-ME

IS-NEMP-C2 125 MHz to 1.0 GHz 200 W VHF, 100 W UHF, 50 W 800 MHz ≤ 0.1dB < 1.1 to 1 over frequency range50 kA per IEC1000-4-5 8/20 µs waveform 500 J

330 Vdc ± 20% 1.5 ns for 2 kV / ns< 250 µJ for 8/20 µs waveform

N Female N Female IS-NEMP-C2

IS-NEMP-C2-MA 125 MHz to 1.0 GHz 200 W VHF, 100 W UHF, 50 W 800 MHz ≤ 0.1dB < 1.1 to 1 over frequency range50 kA per IEC1000-4-5 8/20 µs waveform 500 J

330 Vdc ± 20% 1.5 ns for 2 kV / ns< 250 µJ for 8/20 µs waveform

N Male N Female IS-NEMP-C2-MA

IS-NEMP-C2-ME 125 MHz to 1.0 GHz 200 W VHF, 100 W UHF, 50 W 800 MHz ≤ 0.1dB < 1.1 to 1 over frequency range50 kA per IEC1000-4-5 8/20 µs waveform 500 J

330 Vdc ± 20% 1.5 ns for 2 kV / ns< 250 µJ for 8/20 µs waveform

N Female N Male IS-NEMP-C2-ME

DC Block - NEMP Series

Page 31: Protection Technology Group USA_CATALOG_2011-2012

31

Frequency Range RF Power Insertion Loss VSWR Max Surge Current Turn on Voltage Turn on Time Throughput EnergySurge Side Connector

Protected Side Connector

IS-NEMP-C0 1.5 MHz to 400 MHz 500 W HF, 200 W VHF, 100 W UHF ≤ 0.1dB < 1.1 to 1 @ 2 MHz to 400 MHz50 kA per IEC1000-4-5 8/20 µs waveform 500 J

330 Vdc ± 20% 1.5 ns for 2 kV / ns< 1100 µJ for 8/20 µs waveform

N Female N Female IS-NEMP-C0

IS-NEMP-C0-MA 1.5 MHz to 400 MHz 500 W HF, 200 W VHF, 100 W UHF ≤ 0.1dB < 1.1 to 1 over frequency range50 kA per IEC1000-4-5 8/20 µs waveform 500 J

330 Vdc ± 20% 1.5 ns for 2 kV / ns< 1100 µJ for 8/20 µs waveform

N Male N Female IS-NEMP-C0-MA

IS-NEMP-C0-ME 1.5 MHz to 400 MHz 500 W HF, 200 W VHF, 100 W UHF ≤ 0.1dB < 1.1 to 1 over frequency range50 kA per IEC1000-4-5 8/20 µs waveform 500 J

330 Vdc ± 20% 1.5 ns for 2 kV / ns< 1100 µJ for 8/20 µs waveform

N Female N Male IS-NEMP-C0-ME

IS-NEMP-C1 50 MHz to 700 MHz 200 W VHF, 100 W UHF ≤ 0.1dB < 1.1 to 1 @ 60 MHz to 700 MHz50 kA per IEC1000-4-5 8/20 µs waveform 500 J

330 Vdc ± 20% 1.5 ns for 2 kV / ns< 570 µJ for 8/20 µs waveform

N Female N Female IS-NEMP-C1

IS-NEMP-C1-MA 50 MHz to 700 MHz 200 W VHF, 100 W UHF ≤ 0.1dB < 1.1 to 1 @ 60 MHz to 700 MHz50 kA per IEC1000-4-5 8/20 µs waveform 500 J

330 Vdc ± 20% 1.5 ns for 2 kV / ns< 313 µJ for 8/20 µs waveform

N Male N Female IS-NEMP-C1-MA

IS-NEMP-C1-ME 50 MHz to 700 MHz 200 W VHF, 100 W UHF ≤ 0.1dB < 1.1 to 1 @ 60 MHz to 700 MHz50 kA per IEC1000-4-5 8/20 µs waveform 500 J

330 Vdc ± 20% 1.5 ns for 2 kV / ns< 313 µJ for 8/20 µs waveform

N Female N Male IS-NEMP-C1-ME

IS-NEMP-C2 125 MHz to 1.0 GHz 200 W VHF, 100 W UHF, 50 W 800 MHz ≤ 0.1dB < 1.1 to 1 over frequency range50 kA per IEC1000-4-5 8/20 µs waveform 500 J

330 Vdc ± 20% 1.5 ns for 2 kV / ns< 250 µJ for 8/20 µs waveform

N Female N Female IS-NEMP-C2

IS-NEMP-C2-MA 125 MHz to 1.0 GHz 200 W VHF, 100 W UHF, 50 W 800 MHz ≤ 0.1dB < 1.1 to 1 over frequency range50 kA per IEC1000-4-5 8/20 µs waveform 500 J

330 Vdc ± 20% 1.5 ns for 2 kV / ns< 250 µJ for 8/20 µs waveform

N Male N Female IS-NEMP-C2-MA

IS-NEMP-C2-ME 125 MHz to 1.0 GHz 200 W VHF, 100 W UHF, 50 W 800 MHz ≤ 0.1dB < 1.1 to 1 over frequency range50 kA per IEC1000-4-5 8/20 µs waveform 500 J

330 Vdc ± 20% 1.5 ns for 2 kV / ns< 250 µJ for 8/20 µs waveform

N Female N Male IS-NEMP-C2-ME

Page 32: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Coaxial RF Surge Protection32

• High surge current capability with filter design

• Low let-through voltage and throughput energy

• No DC continuity between center pins

• Weatherized housing

• Insertion loss 0.1 dB

• High powered public safety, TETRA and UHF/VHF radio application

• Standard N, 7/16 DIN Connectors

Features

• IEC 61000-4-5

Standards and Certificates

UHF50HN

Humidity 95% non-condensing

Operating/Storage Temperature -50°C to +85°C

VHF50HN

DC block filter design provides for the ultimate in equipment protection producing the industry’s lowest let-through voltage and throughouput energy. Designed to protect multiple or high power single RF transmitter applications where DC is not required on the coaxial cable.

DC Block

HF Series

Environmental

Page 33: Protection Technology Group USA_CATALOG_2011-2012

33

VHF50HD-MA

VHF50HN

Page 34: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Coaxial RF Surge Protection34

Frequency Range RF Power Insertion Loss VSWR Max Surge Current Throughput EnergySurge Side Connector

Protected Side Connector

UHF50HD 300 MHz to 700 MHz 750 W < 0.1 dB < 1.1 to 1 over frequency range 20 kA per IEC 61000-4-5 8/20 µs waveform < 500 nJ for 3 kA, 8/20 µs waveform DIN Female DIN Female UHF50HD

UHF50HD-MA 300 MHz to 700 MHz 750 W < 0.1 dB < 1.1 to 1 over frequency range 20 kA per IEC 61000-4-5 8/20 µs waveform < 500 nJ for 3 kA, 8/20 µs waveform DIN Male DIN Female UHF50HD-MA

UHF50HD-ME 300 MHz to 700 MHz 750 W < 0.1 dB < 1.1 to 1 over frequency range 20 kA per IEC 61000-4-5 8/20 µs waveform < 500 nJ for 3 kA, 8/20 µs waveform DIN Female DIN Male UHF50HD-ME

UHF50HN 300 MHz to 700 MHz 750 W < 0.1 dB < 1.1 to 1 over frequency range 20 kA per IEC 61000-4-5 8/20 µs waveform < 500 nJ for 3 kA, 8/20 µs waveform N Female N Female UHF50HN

UHF50HN-MA 300 MHz to 700 MHz 750 W < 0.1 dB < 1.1 to 1 over frequency range 20 kA per IEC 61000-4-5 8/20 µs waveform < 500 nJ for 3 kA, 8/20 µs waveform N Male N Female UHF50HN-MA

UHF50HN-ME 300 MHz to 700 MHz 750 W < 0.1 dB < 1.1 to 1 over frequency range 20 kA per IEC 61000-4-5 8/20 µs waveform < 500 nJ for 3 kA, 8/20 µs waveform N Female N Male UHF50HN-ME

VHF50HD 100 MHz to 512 MHz 750 W < 0.1 dB < 1.1 to 1 over frequency range 20 kA per IEC 61000-4-5 8/20 µs waveform < 500 nJ for 3 kA, 8/20 µs waveform DIN Female DIN Female VHF50HD

VHF50HD-MA 100 MHz to 512 MHz 750 W < 0.1 dB < 1.1 to 1 over frequency range 20 kA per IEC 61000-4-5 8/20 µs waveform < 500 nJ for 3 kA, 8/20 µs waveform DIN Male DIN Female VHF50HD-MA

VHF50HD-ME 100 MHz to 512 MHz 750 W < 0.1 dB < 1.1 to 1 over frequency range 20 kA per IEC 61000-4-5 8/20 µs waveform < 500 nJ for 3 kA, 8/20 µs waveform DIN Female DIN Male VHF50HD-ME

VHF50HN 100 MHz to 512 MHz 750 W < 0.1 dB < 1.1 to 1 over frequency range 20 kA per IEC 61000-4-5 8/20 µs waveform < 500 nJ for 3 kA, 8/20 µs waveform N Female N Female VHF50HN

VHF50HN-MA 100 MHz to 512 MHz 750 W < 0.1 dB < 1.1 to 1 over frequency range 20 kA per IEC 61000-4-5 8/20 µs waveform < 500 nJ for 3 kA, 8/20 µs waveform N Male N Female VHF50HN-MA

VHF50HN-ME 100 MHz to 512 MHz 750 W < 0.1 dB < 1.1 to 1 over frequency range 20 kA per IEC 61000-4-5 8/20 µs waveform < 500 nJ for 3 kA, 8/20 µs waveform N Female N Male VHF50HN-ME

DC Block - HF Series

Page 35: Protection Technology Group USA_CATALOG_2011-2012

35

Frequency Range RF Power Insertion Loss VSWR Max Surge Current Throughput EnergySurge Side Connector

Protected Side Connector

UHF50HD 300 MHz to 700 MHz 750 W < 0.1 dB < 1.1 to 1 over frequency range 20 kA per IEC 61000-4-5 8/20 µs waveform < 500 nJ for 3 kA, 8/20 µs waveform DIN Female DIN Female UHF50HD

UHF50HD-MA 300 MHz to 700 MHz 750 W < 0.1 dB < 1.1 to 1 over frequency range 20 kA per IEC 61000-4-5 8/20 µs waveform < 500 nJ for 3 kA, 8/20 µs waveform DIN Male DIN Female UHF50HD-MA

UHF50HD-ME 300 MHz to 700 MHz 750 W < 0.1 dB < 1.1 to 1 over frequency range 20 kA per IEC 61000-4-5 8/20 µs waveform < 500 nJ for 3 kA, 8/20 µs waveform DIN Female DIN Male UHF50HD-ME

UHF50HN 300 MHz to 700 MHz 750 W < 0.1 dB < 1.1 to 1 over frequency range 20 kA per IEC 61000-4-5 8/20 µs waveform < 500 nJ for 3 kA, 8/20 µs waveform N Female N Female UHF50HN

UHF50HN-MA 300 MHz to 700 MHz 750 W < 0.1 dB < 1.1 to 1 over frequency range 20 kA per IEC 61000-4-5 8/20 µs waveform < 500 nJ for 3 kA, 8/20 µs waveform N Male N Female UHF50HN-MA

UHF50HN-ME 300 MHz to 700 MHz 750 W < 0.1 dB < 1.1 to 1 over frequency range 20 kA per IEC 61000-4-5 8/20 µs waveform < 500 nJ for 3 kA, 8/20 µs waveform N Female N Male UHF50HN-ME

VHF50HD 100 MHz to 512 MHz 750 W < 0.1 dB < 1.1 to 1 over frequency range 20 kA per IEC 61000-4-5 8/20 µs waveform < 500 nJ for 3 kA, 8/20 µs waveform DIN Female DIN Female VHF50HD

VHF50HD-MA 100 MHz to 512 MHz 750 W < 0.1 dB < 1.1 to 1 over frequency range 20 kA per IEC 61000-4-5 8/20 µs waveform < 500 nJ for 3 kA, 8/20 µs waveform DIN Male DIN Female VHF50HD-MA

VHF50HD-ME 100 MHz to 512 MHz 750 W < 0.1 dB < 1.1 to 1 over frequency range 20 kA per IEC 61000-4-5 8/20 µs waveform < 500 nJ for 3 kA, 8/20 µs waveform DIN Female DIN Male VHF50HD-ME

VHF50HN 100 MHz to 512 MHz 750 W < 0.1 dB < 1.1 to 1 over frequency range 20 kA per IEC 61000-4-5 8/20 µs waveform < 500 nJ for 3 kA, 8/20 µs waveform N Female N Female VHF50HN

VHF50HN-MA 100 MHz to 512 MHz 750 W < 0.1 dB < 1.1 to 1 over frequency range 20 kA per IEC 61000-4-5 8/20 µs waveform < 500 nJ for 3 kA, 8/20 µs waveform N Male N Female VHF50HN-MA

VHF50HN-ME 100 MHz to 512 MHz 750 W < 0.1 dB < 1.1 to 1 over frequency range 20 kA per IEC 61000-4-5 8/20 µs waveform < 500 nJ for 3 kA, 8/20 µs waveform N Female N Male VHF50HN-ME

Page 36: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Coaxial RF Surge Protection36

• Patented dual path RF and DC protection

• Multi-strike capacity

• Weatherized housing

• Low throughput energy

• Wide bandwith

Features

• IEC 60529IP67

• Bellcore #TA-NWT-00487

• UL 497B

• RoHS compliant

Standards and Certificates

DGXZ+06NFNF-A

Humidity 95% non-condensing

Operating/Storage Temperature -50°C to +85°C

Vibration 1 G @ 5 Hz to 500 HzDGXZ+06NFNF-A

The GX Series radio frequency DC pass filter protectors are ideal for RF coaxial applications where DC is required. The GX Series can be used on GPS and point to point radios as well as active tower mounted electronic equipment that operate in the range of 30 to 2,500 MHz. The GX Series is available in a multitude of connector configurations each exhibiting low return loss, insertion loss and let-through voltage.

DC Pass

GXZ Series

Environmental

Page 37: Protection Technology Group USA_CATALOG_2011-2012

37

DGXZ+24DFDF-A

DGXZ+06DFDM-A

Page 38: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Coaxial RF Surge Protection38

Frequency Range RF Power Insertion Loss VSWR

Max Continuous Operating Voltage

Max Continuous Operating Current

Max Surge CurrentTurn on Voltage

Turn on Time Throughput EnergySurge Side Connector

Protected Side Connector

BGXZ+24NFNF-A 30 MHz to 400 MHz 6.25 W < 0.1 dB< 1.1 to 1 over frequency range

+24 Vdc < 4.0 A3 kA per IEC 61000-4-5 8/20 µs waveform

+26 Vdc 4 ns for 2 kV/ns≤ 1300 µJ for 3 kA, 8/20 µs waveform

N Female N Female BGXZ+24NFNF-A

CGXZ+15NFNF-A 400 MHz to 1200 MHz 300 W < 0.1 dB< 1.1 to 1 over frequency range

+15 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

+16.5 Vdc 4 ns for 2 kV/ns≤ 500 µJ for 3 kA, 8/20 µs waveform

N Female N Female CGXZ+15NFNF-A

CGXZ+24NFNF-A 400 MHz to 1200 MHz 300 W < 0.1 dB< 1.1 to 1 over frequency range

+24 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

+26.5 Vdc 4 ns for 2 kV/ns≤ 1 mJ for 3 kA, 8/20 µs waveform

N Female N Female CGXZ+24NFNF-A

CGXZ+36NFNF-A 400 MHz to 1200 MHz 300 W < 0.1 dB< 1.1 to 1 over frequency range

+36 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

+40 Vdc 4 ns for 2 kV/ns≤ 1500 µJ for 3 kA, 8/20 µs waveform

N Female N Female CGXZ+36NFNF-A

CGXZ+48NFNF-A 400 MHz to 1200 MHz 300 W < 0.1 dB< 1.1 to 1 over frequency range

+48 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

+54 Vdc 4 ns for 2 kV/ns≤ 2.5 mJ for 3 kA, 8/20 µs waveform

N Female N Female CGXZ+48NFNF-A

CGXZ-15NFNF-A 400 MHz to 1200 MHz 300 W < 0.1 dB< 1.1 to 1 over frequency range

-15 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

-16.5 Vdc 4 ns for 2 kV/ns≤ 500 µJ for 3 kA, 8/20 µs waveform

N Female N Female CGXZ-15NFNF-A

CGXZ-48NFNF-A 400 MHz to 1200 MHz 300 W < 0.1 dB< 1.1 to 1 over frequency range

-48 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

-54 Vdc 4 ns for 2 kV/ns≤ 2.5 mJ for 3 kA, 8/20 µs waveform

N Female N Female CGXZ-48NFNF-A

DGXZ+06DFDF-A 800 MHz to 2500 MHz 300 W < 0.1 dB< 1.1 to 1 over frequency range

+ 6 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

+6.5 Vdc 4 ns for 2 kV/ns≤ 175 µJ for 3 kA, 8/20 µs waveform

DIN Female DIN Female DGXZ+06DFDF-A

DGXZ+06NFNF-A 800 MHz to 2500 MHz 300 W < 0.1 dB< 1.1 to 1 over frequency range

+ 6 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

+6.5 Vdc 4 ns for 2 kV/ns≤ 175 µJ for 3 kA, 8/20 µs waveform

N Female N Female DGXZ+06NFNF-A

DGXZ+06NMNF-U 800 MHz to 2500 MHz 300 W < 0.1 dB< 1.1 to 1 over frequency range

+ 6 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

+6.5 Vdc 4 ns for 2 kV/ns≤ 175 µJ for 3 kA, 8/20 µs waveform

N Male N Female DGXZ+06NMNF-U

DGXZ+06TFTF-A 800 MHz to 2500 MHz 300 W < 0.1 dB< 1.1 to 1 over frequency range

+ 6 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

+6.5 Vdc 4 ns for 2 kV/ns≤ 175 µJ for 3 kA, 8/20 µs waveform

TNC Female TNC Female DGXZ+06TFTF-A

DGXZ+15DFDF-A 800 MHz to 2500 MHz 300 W < 0.1 dB< 1.1 to 1 over frequency range

+15 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

+16.5 Vdc 4 ns for 2 kV/ns≤ 500 µJ for 3 kA, 8/20 µs waveform

DIN Female DIN Female DGXZ+15DFDF-A

DGXZ+15NFNF-A 800 MHz to 2500 MHz 300 W < 0.1 dB< 1.1 to 1 over frequency range

+15 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

+16.5 Vdc 4 ns for 2 kV/ns≤ 500 µJ for 3 kA, 8/20 µs waveform

N Female N Female DGXZ+15NFNF-A

DGXZ+15TFTF-A 800 MHz to 2500 MHz 300 W < 0.1 dB< 1.1 to 1 over frequency range

+15 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

+16.5 Vdc 4 ns for 2 kV/ns≤ 500 µJ for 3 kA, 8/20 µs waveform

TNC Female TNC Female DGXZ+15TFTF-A

DGXZ+24DFDF-A 800 MHz to 2500 MHz 300 W < 0.1 dB< 1.1 to 1 over frequency range

+24 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

+26.5 Vdc 4 ns for 2 kV/ns≤ 1 mJ for 3 kA, 8/20 µs waveform

DIN Female DIN Female DGXZ+24DFDF-A

DGXZ+24NFNF-A 800 MHz to 2500 MHz 300 W < 0.1 dB< 1.1 to 1 over frequency range

+24 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

+26.5 Vdc 4 ns for 2 kV/ns≤ 1 mJ for 3 kA, 8/20 µs waveform

N Female N Female DGXZ+24NFNF-A

DGXZ+36NFNF-A 800 MHz to 2500 MHz 300 W < 0.1 dB< 1.1 to 1 over frequency range

+36 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

+40 Vdc 4 ns for 2 kV/ns≤ 1.5 mJ for 3 kA, 8/20 µs waveform

N Female N Female DGXZ+36NFNF-A

DGXZ+48DFDF-A 800 MHz to 2500 MHz 300 W < 0.1 dB< 1.1 to 1 over frequency range

+48 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

+54 Vdc 4 ns for 2 kV/ns≤ 2.5 mJ for 3 kA, 8/20 µs waveform

DIN Female DIN Female DGXZ+48DFDF-A

DC Pass - GXZ Series

Page 39: Protection Technology Group USA_CATALOG_2011-2012

39

Frequency Range RF Power Insertion Loss VSWR

Max Continuous Operating Voltage

Max Continuous Operating Current

Max Surge CurrentTurn on Voltage

Turn on Time Throughput EnergySurge Side Connector

Protected Side Connector

BGXZ+24NFNF-A 30 MHz to 400 MHz 6.25 W < 0.1 dB< 1.1 to 1 over frequency range

+24 Vdc < 4.0 A3 kA per IEC 61000-4-5 8/20 µs waveform

+26 Vdc 4 ns for 2 kV/ns≤ 1300 µJ for 3 kA, 8/20 µs waveform

N Female N Female BGXZ+24NFNF-A

CGXZ+15NFNF-A 400 MHz to 1200 MHz 300 W < 0.1 dB< 1.1 to 1 over frequency range

+15 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

+16.5 Vdc 4 ns for 2 kV/ns≤ 500 µJ for 3 kA, 8/20 µs waveform

N Female N Female CGXZ+15NFNF-A

CGXZ+24NFNF-A 400 MHz to 1200 MHz 300 W < 0.1 dB< 1.1 to 1 over frequency range

+24 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

+26.5 Vdc 4 ns for 2 kV/ns≤ 1 mJ for 3 kA, 8/20 µs waveform

N Female N Female CGXZ+24NFNF-A

CGXZ+36NFNF-A 400 MHz to 1200 MHz 300 W < 0.1 dB< 1.1 to 1 over frequency range

+36 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

+40 Vdc 4 ns for 2 kV/ns≤ 1500 µJ for 3 kA, 8/20 µs waveform

N Female N Female CGXZ+36NFNF-A

CGXZ+48NFNF-A 400 MHz to 1200 MHz 300 W < 0.1 dB< 1.1 to 1 over frequency range

+48 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

+54 Vdc 4 ns for 2 kV/ns≤ 2.5 mJ for 3 kA, 8/20 µs waveform

N Female N Female CGXZ+48NFNF-A

CGXZ-15NFNF-A 400 MHz to 1200 MHz 300 W < 0.1 dB< 1.1 to 1 over frequency range

-15 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

-16.5 Vdc 4 ns for 2 kV/ns≤ 500 µJ for 3 kA, 8/20 µs waveform

N Female N Female CGXZ-15NFNF-A

CGXZ-48NFNF-A 400 MHz to 1200 MHz 300 W < 0.1 dB< 1.1 to 1 over frequency range

-48 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

-54 Vdc 4 ns for 2 kV/ns≤ 2.5 mJ for 3 kA, 8/20 µs waveform

N Female N Female CGXZ-48NFNF-A

DGXZ+06DFDF-A 800 MHz to 2500 MHz 300 W < 0.1 dB< 1.1 to 1 over frequency range

+ 6 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

+6.5 Vdc 4 ns for 2 kV/ns≤ 175 µJ for 3 kA, 8/20 µs waveform

DIN Female DIN Female DGXZ+06DFDF-A

DGXZ+06NFNF-A 800 MHz to 2500 MHz 300 W < 0.1 dB< 1.1 to 1 over frequency range

+ 6 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

+6.5 Vdc 4 ns for 2 kV/ns≤ 175 µJ for 3 kA, 8/20 µs waveform

N Female N Female DGXZ+06NFNF-A

DGXZ+06NMNF-U 800 MHz to 2500 MHz 300 W < 0.1 dB< 1.1 to 1 over frequency range

+ 6 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

+6.5 Vdc 4 ns for 2 kV/ns≤ 175 µJ for 3 kA, 8/20 µs waveform

N Male N Female DGXZ+06NMNF-U

DGXZ+06TFTF-A 800 MHz to 2500 MHz 300 W < 0.1 dB< 1.1 to 1 over frequency range

+ 6 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

+6.5 Vdc 4 ns for 2 kV/ns≤ 175 µJ for 3 kA, 8/20 µs waveform

TNC Female TNC Female DGXZ+06TFTF-A

DGXZ+15DFDF-A 800 MHz to 2500 MHz 300 W < 0.1 dB< 1.1 to 1 over frequency range

+15 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

+16.5 Vdc 4 ns for 2 kV/ns≤ 500 µJ for 3 kA, 8/20 µs waveform

DIN Female DIN Female DGXZ+15DFDF-A

DGXZ+15NFNF-A 800 MHz to 2500 MHz 300 W < 0.1 dB< 1.1 to 1 over frequency range

+15 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

+16.5 Vdc 4 ns for 2 kV/ns≤ 500 µJ for 3 kA, 8/20 µs waveform

N Female N Female DGXZ+15NFNF-A

DGXZ+15TFTF-A 800 MHz to 2500 MHz 300 W < 0.1 dB< 1.1 to 1 over frequency range

+15 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

+16.5 Vdc 4 ns for 2 kV/ns≤ 500 µJ for 3 kA, 8/20 µs waveform

TNC Female TNC Female DGXZ+15TFTF-A

DGXZ+24DFDF-A 800 MHz to 2500 MHz 300 W < 0.1 dB< 1.1 to 1 over frequency range

+24 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

+26.5 Vdc 4 ns for 2 kV/ns≤ 1 mJ for 3 kA, 8/20 µs waveform

DIN Female DIN Female DGXZ+24DFDF-A

DGXZ+24NFNF-A 800 MHz to 2500 MHz 300 W < 0.1 dB< 1.1 to 1 over frequency range

+24 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

+26.5 Vdc 4 ns for 2 kV/ns≤ 1 mJ for 3 kA, 8/20 µs waveform

N Female N Female DGXZ+24NFNF-A

DGXZ+36NFNF-A 800 MHz to 2500 MHz 300 W < 0.1 dB< 1.1 to 1 over frequency range

+36 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

+40 Vdc 4 ns for 2 kV/ns≤ 1.5 mJ for 3 kA, 8/20 µs waveform

N Female N Female DGXZ+36NFNF-A

DGXZ+48DFDF-A 800 MHz to 2500 MHz 300 W < 0.1 dB< 1.1 to 1 over frequency range

+48 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

+54 Vdc 4 ns for 2 kV/ns≤ 2.5 mJ for 3 kA, 8/20 µs waveform

DIN Female DIN Female DGXZ+48DFDF-A

Page 40: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Coaxial RF Surge Protection40

Frequency Range RF Power Insertion Loss VSWR

Max Continuous Operating Voltage

Max Continuous Operating Current

Max Surge CurrentTurn on Voltage

Turn on Time Throughput EnergySurge Side Connector

Protected Side Connector

DGXZ+48NFNF-A 800 MHz to 2500 MHz 300 W < 0.1 dB< 1.1 to 1 over frequency range

+48 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

+54 Vdc 4 ns for 2 kV/ns≤ 2.5 mJ for 3 kA, 8/20 µs waveform

N Female N Female DGXZ+48NFNF-A

DGXZ+60NFNF-A 800 MHz to 2500 MHz 300 W < 0.1 dB< 1.1 to 1 over frequency range

+60 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

+66.5 Vdc 4 ns for 2 kV/ns≤ 2.5 mJ for 3 kA, 8/20 µs waveform

N Female N Female DGXZ+60NFNF-A

DGXZ-48DFDF-A 800 MHz to 2500 MHz 40 W < 0.1 dB< 1.1 to 1 over frequency range

-48 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

-54 Vdc 4 ns for 2 kV/ns≤ 2.5 mJ for 3 kA, 8/20 µs waveform

DIN Female DIN Female DGXZ-48DFDF-A

DGXZ-48NFNF-A 800 MHz to 2500 MHz 40 W < 0.1 dB< 1.1 to 1 over frequency range

-48 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

-54 Vdc 4 ns for 2 kV/ns≤ 2.5 mJ for 3 kA, 8/20 µs waveform

N Female N Female DGXZ-48NFNF-A

DGXZ-60NFNF-A 800 MHz to 2500 MHz 40 W < 0.1 dB< 1.1 to 1 over frequency range

-60 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

-66.5 Vdc 4 ns for 2 kV/ns≤ 2.5 mJ for 3 kA, 8/20 µs waveform

N Female N Female DGXZ-60NFNF-A

DGXE+30NMNF-A 650 MHz to 2700 MHz 400 Wrms average < 0.1 dB< 1.1 to 1 over frequency range

+30 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

+33 Vdc 4ns for 2 kV/ns

4 ns for 2 kV/ns≤ 1.5 mJ for 3 kA, 8/20 µs waveform

N Male N Female DGXE+30NMNF-A

DC Pass - GXZ Series

Page 41: Protection Technology Group USA_CATALOG_2011-2012

41

Frequency Range RF Power Insertion Loss VSWR

Max Continuous Operating Voltage

Max Continuous Operating Current

Max Surge CurrentTurn on Voltage

Turn on Time Throughput EnergySurge Side Connector

Protected Side Connector

DGXZ+48NFNF-A 800 MHz to 2500 MHz 300 W < 0.1 dB< 1.1 to 1 over frequency range

+48 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

+54 Vdc 4 ns for 2 kV/ns≤ 2.5 mJ for 3 kA, 8/20 µs waveform

N Female N Female DGXZ+48NFNF-A

DGXZ+60NFNF-A 800 MHz to 2500 MHz 300 W < 0.1 dB< 1.1 to 1 over frequency range

+60 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

+66.5 Vdc 4 ns for 2 kV/ns≤ 2.5 mJ for 3 kA, 8/20 µs waveform

N Female N Female DGXZ+60NFNF-A

DGXZ-48DFDF-A 800 MHz to 2500 MHz 40 W < 0.1 dB< 1.1 to 1 over frequency range

-48 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

-54 Vdc 4 ns for 2 kV/ns≤ 2.5 mJ for 3 kA, 8/20 µs waveform

DIN Female DIN Female DGXZ-48DFDF-A

DGXZ-48NFNF-A 800 MHz to 2500 MHz 40 W < 0.1 dB< 1.1 to 1 over frequency range

-48 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

-54 Vdc 4 ns for 2 kV/ns≤ 2.5 mJ for 3 kA, 8/20 µs waveform

N Female N Female DGXZ-48NFNF-A

DGXZ-60NFNF-A 800 MHz to 2500 MHz 40 W < 0.1 dB< 1.1 to 1 over frequency range

-60 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

-66.5 Vdc 4 ns for 2 kV/ns≤ 2.5 mJ for 3 kA, 8/20 µs waveform

N Female N Female DGXZ-60NFNF-A

DGXE+30NMNF-A 650 MHz to 2700 MHz 400 Wrms average < 0.1 dB< 1.1 to 1 over frequency range

+30 Vdc < 4.0 A20 kA per IEC 61000-4-5 8/20 µs waveform

+33 Vdc 4ns for 2 kV/ns

4 ns for 2 kV/ns≤ 1.5 mJ for 3 kA, 8/20 µs waveform

N Male N Female DGXE+30NMNF-A

Page 42: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Coaxial RF Surge Protection42

• Coaxial RF protection with integrated Bias-T

• Patented technology

• VSWR: ≤1.1:1 over frequency range

• Multi-strike capability, high MTBF

• Low throughput energy

• Weatherized

Features

• IEC 61000-4-5

• IEC 60529

• UL 497B

• RoHS compliant

Standards and Certificates

CGXJ+30NFNM-A

Humidity 95% non-condensing

Operating/Storage Temperature -50°C to +85°C

Enclosure Rating IEC 60529, IP 67

CGXJ+30NFNM-A

Integrated Bias-T, hybrid, multi-stage, multi-strike, fast response, high current capacity, DC pass coaxial lightning protection available with DIN and N connectors with frequency ranges of 400 MHz to 1.2 GHz and 800 MHz to 2.5 GHz.

DC Pass

GXJ Series

Environmental

Page 43: Protection Technology Group USA_CATALOG_2011-2012

43

DGXJ+15NFNF-A

DGXJ+36DFDF-A

Page 44: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Coaxial RF Surge Protection44

Frequency Range RF Power Insertion Loss VSWR

Max Continuous Operating Voltage

Max Continuous Operating Current

Max Surge CurrentTurn on Voltage

Turn on Time Throughput EnergySurge Side Connector

Protected Side Connector

CGXJ+15NFNF-A 400 MHz to 1.2 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+15 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +20 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

N Female N Female CGXJ+15NFNF-A

CGXJ+24NFNF-A 400 MHz to 1.2 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+24 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +26 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

N Female N Female CGXJ+24NFNF-A

CGXJ+30NFNM-A 400 MHz to 1.2 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+30 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +33 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

N Female N Male CGXJ+30NFNM-A

CGXJ+36DFDF-A 400 MHz to 1.2 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+36 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +40 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

DIN Female DIN Female CGXJ+36DFDF-A

CGXJ+36DFDM-A 400 MHz to 1.2 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+36 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +40 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

DIN Female DIN Male CGXJ+36DFDM-A

CGXJ+15NFNM-A 400 MHz to 1.2 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+15 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +20 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

N Female N Male CGXJ+15NFNM-A

CGXJ+36NFNF-A 400 MHz to 1.2 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+36 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +40 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

N Female N Female CGXJ+36NFNF-A

CGXJ+36NFNM-A 400 MHz to 1.2 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+36 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +40 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

N Female N Male CGXJ+36NFNM-A

CGXJ+36NMNF-A 400 MHz to 1.2 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+36 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +40 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

N Male N Female CGXJ+36NMNF-A

DGXJ+15DFDF-A 800 MHz to 2.5 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+15 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +20 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

DIN Female DIN Female DGXJ+15DFDF-A

DGXJ+15DFDM-A 800 MHz to 2.5 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+15 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +20 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

DIN Female DIN Male DGXJ+15DFDM-A

DGXJ+15DMDF-A 800 MHz to 2.5 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+15 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +20 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

DIN Male DIN Female DGXJ+15DMDF-A

DGXJ+15NFNF-A 800 MHz to 2.5 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+15 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +20 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

N Female N Female DGXJ+15NFNF-A

DGXJ+24DFDF-A 800 MHz to 2.5 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+24 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +26 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

DIN Female DIN Female DGXJ+24DFDF-A

DGXJ+24DFDM-A 800 MHz to 2.5 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+24 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +26 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

DIN Female DIN Male DGXJ+24DFDM-A

DC Pass - GXJ Series

Page 45: Protection Technology Group USA_CATALOG_2011-2012

45

Frequency Range RF Power Insertion Loss VSWR

Max Continuous Operating Voltage

Max Continuous Operating Current

Max Surge CurrentTurn on Voltage

Turn on Time Throughput EnergySurge Side Connector

Protected Side Connector

CGXJ+15NFNF-A 400 MHz to 1.2 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+15 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +20 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

N Female N Female CGXJ+15NFNF-A

CGXJ+24NFNF-A 400 MHz to 1.2 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+24 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +26 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

N Female N Female CGXJ+24NFNF-A

CGXJ+30NFNM-A 400 MHz to 1.2 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+30 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +33 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

N Female N Male CGXJ+30NFNM-A

CGXJ+36DFDF-A 400 MHz to 1.2 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+36 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +40 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

DIN Female DIN Female CGXJ+36DFDF-A

CGXJ+36DFDM-A 400 MHz to 1.2 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+36 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +40 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

DIN Female DIN Male CGXJ+36DFDM-A

CGXJ+15NFNM-A 400 MHz to 1.2 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+15 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +20 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

N Female N Male CGXJ+15NFNM-A

CGXJ+36NFNF-A 400 MHz to 1.2 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+36 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +40 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

N Female N Female CGXJ+36NFNF-A

CGXJ+36NFNM-A 400 MHz to 1.2 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+36 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +40 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

N Female N Male CGXJ+36NFNM-A

CGXJ+36NMNF-A 400 MHz to 1.2 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+36 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +40 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

N Male N Female CGXJ+36NMNF-A

DGXJ+15DFDF-A 800 MHz to 2.5 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+15 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +20 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

DIN Female DIN Female DGXJ+15DFDF-A

DGXJ+15DFDM-A 800 MHz to 2.5 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+15 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +20 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

DIN Female DIN Male DGXJ+15DFDM-A

DGXJ+15DMDF-A 800 MHz to 2.5 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+15 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +20 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

DIN Male DIN Female DGXJ+15DMDF-A

DGXJ+15NFNF-A 800 MHz to 2.5 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+15 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +20 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

N Female N Female DGXJ+15NFNF-A

DGXJ+24DFDF-A 800 MHz to 2.5 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+24 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +26 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

DIN Female DIN Female DGXJ+24DFDF-A

DGXJ+24DFDM-A 800 MHz to 2.5 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+24 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +26 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

DIN Female DIN Male DGXJ+24DFDM-A

Page 46: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Coaxial RF Surge Protection46

Frequency Range RF Power Insertion Loss VSWR

Max Continuous Operating Voltage

Max Continuous Operating Current

Max Surge CurrentTurn on Voltage

Turn on Time Throughput EnergySurge Side Connector

Protected Side Connector

DGXJ+24DFNM-A 800 MHz to 2.5 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+24 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +26 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

DIN Female N Male DGXJ+24DFNM-A

DGXJ+24DMDF-A 800 MHz to 2.5 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+24 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +26 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

DIN Male DIN Female DGXJ+24DMDF-A

DGXJ+24NFNF-A 800 MHz to 2.5 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+24 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +26 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

N Female N Female DGXJ+24NFNF-A

DGXJ+24NFNM-A 800 MHz to 2.5 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+24 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +26 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

N Female N Male DGXJ+24NFNM-A

DGXJ+36DFDF-A 800 MHz to 2.5 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+36 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +40 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

DIN Female DIN Female DGXJ+36DFDF-A

DGXJ+36DFDM-A 800 MHz to 2.5 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+36 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +40 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

DIN Female DIN Male DGXJ+36DFDM-A

DGXJ+36DFNM-A 800 MHz to 2.5 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+36 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +40 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

DIN Female N Male DGXJ+36DFNM-A

DGXJ+36DMDF-A 800 MHz to 2.5 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+36 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +40 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

DIN Male DIN Female DGXJ+36DMDF-A

DGXJ+48DFDF-A 800 MHz to 2.5 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+48 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +53 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

DIN Female DIN Female DGXJ+48DFDF-A

DGXJ+48NFNF-A 800 MHz to 2.5 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+48 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +53 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

N Female N Female DGXJ+48NFNF-A

DGXJ-48DFDM-A 800 MHz to 2.5 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

-48 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs -53 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

DIN Female DIN Female DGXJ-48DFDM-A

DGXJ-48NFNF-A 800 MHz to 2.5 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

-48 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs -53 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

N Female N Female DGXJ-48NFNF-A

DC Pass - GXJ Series

Page 47: Protection Technology Group USA_CATALOG_2011-2012

47

Frequency Range RF Power Insertion Loss VSWR

Max Continuous Operating Voltage

Max Continuous Operating Current

Max Surge CurrentTurn on Voltage

Turn on Time Throughput EnergySurge Side Connector

Protected Side Connector

DGXJ+24DFNM-A 800 MHz to 2.5 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+24 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +26 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

DIN Female N Male DGXJ+24DFNM-A

DGXJ+24DMDF-A 800 MHz to 2.5 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+24 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +26 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

DIN Male DIN Female DGXJ+24DMDF-A

DGXJ+24NFNF-A 800 MHz to 2.5 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+24 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +26 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

N Female N Female DGXJ+24NFNF-A

DGXJ+24NFNM-A 800 MHz to 2.5 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+24 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +26 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

N Female N Male DGXJ+24NFNM-A

DGXJ+36DFDF-A 800 MHz to 2.5 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+36 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +40 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

DIN Female DIN Female DGXJ+36DFDF-A

DGXJ+36DFDM-A 800 MHz to 2.5 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+36 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +40 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

DIN Female DIN Male DGXJ+36DFDM-A

DGXJ+36DFNM-A 800 MHz to 2.5 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+36 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +40 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

DIN Female N Male DGXJ+36DFNM-A

DGXJ+36DMDF-A 800 MHz to 2.5 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+36 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +40 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

DIN Male DIN Female DGXJ+36DMDF-A

DGXJ+48DFDF-A 800 MHz to 2.5 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+48 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +53 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

DIN Female DIN Female DGXJ+48DFDF-A

DGXJ+48NFNF-A 800 MHz to 2.5 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

+48 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs +53 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

N Female N Female DGXJ+48NFNF-A

DGXJ-48DFDM-A 800 MHz to 2.5 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

-48 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs -53 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

DIN Female DIN Female DGXJ-48DFDM-A

DGXJ-48NFNF-A 800 MHz to 2.5 GHz 300 W average≤ 0.1 dB over frequency range

≤ 1.1:1 over frequency range

-48 Vdc ≤ 4.0 A 20 kA per IEC 6100-4-5 8/20µs -53 Vdc 4 ns for 2 kV ns<25 µJ for 3 kA, 8/20 µs waveform

N Female N Female DGXJ-48NFNF-A

Page 48: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Coaxial RF Surge Protection48

• High surge current capability

• High power configurations available

• ±60 Vdc pass configurations available (DT models)

• Weatherized

Features

• IEC 61000-4-5

Standards and Certificates

GT-NFF-AL

Humidity 95% non-condensing

Operating/Storage Temperature -55°C to +85°C

GT-NFF-AL

High performance gas tube coaxial protection for RF signals. Performs well in applications where a higher voltage let-through is acceptable, yet good RF performance is essential.

DC Pass

GT Series

Environmental

Page 49: Protection Technology Group USA_CATALOG_2011-2012

49

GT-DFM-AL

GT-NFSF-AL

DT-NFM

Page 50: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Coaxial RF Surge Protection50

Frequency Range RF Power Insertion Loss VSWRMax Continuous Operating Current

Max Surge Current Surge Side Connector Protected Side Connector

GT-NFF-AL DC to 7.0 GHz90 W @ 30 MHz, 9 W @ 3 GHz

≤0.1 dB @ DC to 3.0 GHz, ≤0.25 dB @ 3.0 to 7.0 GHz

≤1.1:1 DC to 3.0 GHz, ≤1.2:1 3.0 to 4.0 GHz, ≤1.4:1 4.0 to 7.0 GHz

10 A 20 kA 8/20 µs per IEC 61000-4-5 N Female N Female GT-NFF-AL

GT-NFSF-AL DC to 7.0 GHz90 W @ 30 MHz, 9 W @ 3 GHz

≤0.1 dB @ DC to 3.0 GHz, ≤0.25 dB @ 3.0 to 7.0 GHz

≤1.1:1 DC to 3.0 GHz, ≤1.2:1 3.0 to 4.0 GHz, ≤1.4:1 4.0 to 7.0 GHz

10 A 20 kA 8/20 µs per IEC 61000-4-5 N Female N Female GT-NFSF-AL

GT-NFM-AL DC to 7.0 GHz90 W @ 30 MHz, 9 W @ 3 GHz

≤0.1 dB @ DC to 3.0 GHz, ≤0.25 dB @ 3.0 to 7.0 GHz

≤1.1:1 DC to 3.0 GHz, ≤1.2:1 3.0 to 4.0 GHz, ≤1.4:1 4.0 to 7.0 GHz

10 A 20 kA 8/20 µs per IEC 61000-4-5 N Female N Male GT-NFM-AL

GT-DFF-AL DC to 3.0 GHz90 W @ 30 MHz, 9 W @ 3 GHz

≤0.1 dB @ DC to 3.0 GHz ≤1.1:1 DC to 3.0 GHz 10 A 20 kA 8/20 µs per IEC 61000-4-5 DIN Female DIN Female GT-DFF-AL

GT-DFM-AL DC to 3.0 GHz90 W @ 30 MHz, 9 W @ 3 GHz

≤0.1 dB @ DC to 3.0 GHz ≤1.1:1 DC to 3.0 GHz 10 A 20 kA 8/20 µs per IEC 61000-4-5 DIN Female DIN Male GT-DFM-AL

GTH-NFF-AL DC to 7.0 GHz1 kW @ 30 MHz, 300 W @ 3 GHz

≤0.1 dB @ DC to 3.0 GHz, ≤0.25 dB @ 3.0 to 7.0 GHz

≤1.1:1 DC to 3.0 GHz, ≤1.2:1 3.0 to 4.0 GHz, ≤1.4:1 4.0 to 7.0 GHz

10 A 20 kA 8/20 µs per IEC 61000-4-5 N Female N Female GTH-NFF-AL

GTH-NFM-AL DC to 7.0 GHz1 kW @ 30 MHz, 300 W @ 3 GHz

≤0.1 dB @ DC to 3.0 GHz, ≤0.25 dB @ 3.0 to 7.0 GHz

≤1.1:1 DC to 3.0 GHz, ≤1.2:1 3.0 to 4.0 GHz, ≤1.4:1 4.0 to 7.0 GHz

10 A 20 kA 8/20 µs per IEC 61000-4-5 N Female N Male GTH-NFM-AL

GT-TFF-AL DC to 7.0 GHz1 kW @ 30 MHz, 300 W @ 3 GHz

≤0.1 dB @ DC to 3.0 GHz, ≤0.25 dB @ 3.0 to 5.0 GHz, ≤0.5 dB @ 5.0 to 7.0 GHz

≤1.1:1 DC to 2.0 GHz, ≤1.2:1 2.0 to 3.0 GHz, ≤1.4:1 3.0 to 7.0 GHz

10 A 20 kA 8/20 µs per IEC 61000-4-5 TNC Female TNC Female GT-TFF-AL

GT-TFM-AL DC to 7.0 GHz1 kW @ 30 MHz, 300 W @ 3 GHz

≤0.1 dB @ DC to 3.0 GHz, ≤0.25 dB @ 3.0 to 5.0 GHz, ≤0.5 dB @ 5.0 to 7.0 GHz

≤1.1:1 DC to 2.0 GHz, ≤1.2:1 2.0 to 3.0 GHz, ≤1.4:1 3.0 to 7.0 GHz

10 A 20 kA 8/20 µs per IEC 61000-4-5 TNC Female TNC Male GT-TFM-AL

DT-NFF DC to 3.0 GHz 40 W @ 30 MHz≤0.1 dB @ DC to 1.0 GHz, ≤0.25 dB @ 1.0 to 3.0 GHz

≤1.1:1 DC to 1.0 GHz 10 A 4 kA 8/20 µs per IEC 61000-4-5 N Female N Female DT-NFF

DT-NFM DC to 3.0 GHz 40 W @ 30 MHz≤0.1 dB @ DC to 1.0 GHz, ≤0.25 dB @ 1.0 to 3.0 GHz

≤1.1:1 DC to 1.0 GHz, ≤1.15:1 DC to 3.0 GHz

10 A 4 kA 8/20 µs per IEC 61000-4-5 N Female N Male DT-NFM

DC Pass - GT Series

Page 51: Protection Technology Group USA_CATALOG_2011-2012

51

Frequency Range RF Power Insertion Loss VSWRMax Continuous Operating Current

Max Surge Current Surge Side Connector Protected Side Connector

GT-NFF-AL DC to 7.0 GHz90 W @ 30 MHz, 9 W @ 3 GHz

≤0.1 dB @ DC to 3.0 GHz, ≤0.25 dB @ 3.0 to 7.0 GHz

≤1.1:1 DC to 3.0 GHz, ≤1.2:1 3.0 to 4.0 GHz, ≤1.4:1 4.0 to 7.0 GHz

10 A 20 kA 8/20 µs per IEC 61000-4-5 N Female N Female GT-NFF-AL

GT-NFSF-AL DC to 7.0 GHz90 W @ 30 MHz, 9 W @ 3 GHz

≤0.1 dB @ DC to 3.0 GHz, ≤0.25 dB @ 3.0 to 7.0 GHz

≤1.1:1 DC to 3.0 GHz, ≤1.2:1 3.0 to 4.0 GHz, ≤1.4:1 4.0 to 7.0 GHz

10 A 20 kA 8/20 µs per IEC 61000-4-5 N Female N Female GT-NFSF-AL

GT-NFM-AL DC to 7.0 GHz90 W @ 30 MHz, 9 W @ 3 GHz

≤0.1 dB @ DC to 3.0 GHz, ≤0.25 dB @ 3.0 to 7.0 GHz

≤1.1:1 DC to 3.0 GHz, ≤1.2:1 3.0 to 4.0 GHz, ≤1.4:1 4.0 to 7.0 GHz

10 A 20 kA 8/20 µs per IEC 61000-4-5 N Female N Male GT-NFM-AL

GT-DFF-AL DC to 3.0 GHz90 W @ 30 MHz, 9 W @ 3 GHz

≤0.1 dB @ DC to 3.0 GHz ≤1.1:1 DC to 3.0 GHz 10 A 20 kA 8/20 µs per IEC 61000-4-5 DIN Female DIN Female GT-DFF-AL

GT-DFM-AL DC to 3.0 GHz90 W @ 30 MHz, 9 W @ 3 GHz

≤0.1 dB @ DC to 3.0 GHz ≤1.1:1 DC to 3.0 GHz 10 A 20 kA 8/20 µs per IEC 61000-4-5 DIN Female DIN Male GT-DFM-AL

GTH-NFF-AL DC to 7.0 GHz1 kW @ 30 MHz, 300 W @ 3 GHz

≤0.1 dB @ DC to 3.0 GHz, ≤0.25 dB @ 3.0 to 7.0 GHz

≤1.1:1 DC to 3.0 GHz, ≤1.2:1 3.0 to 4.0 GHz, ≤1.4:1 4.0 to 7.0 GHz

10 A 20 kA 8/20 µs per IEC 61000-4-5 N Female N Female GTH-NFF-AL

GTH-NFM-AL DC to 7.0 GHz1 kW @ 30 MHz, 300 W @ 3 GHz

≤0.1 dB @ DC to 3.0 GHz, ≤0.25 dB @ 3.0 to 7.0 GHz

≤1.1:1 DC to 3.0 GHz, ≤1.2:1 3.0 to 4.0 GHz, ≤1.4:1 4.0 to 7.0 GHz

10 A 20 kA 8/20 µs per IEC 61000-4-5 N Female N Male GTH-NFM-AL

GT-TFF-AL DC to 7.0 GHz1 kW @ 30 MHz, 300 W @ 3 GHz

≤0.1 dB @ DC to 3.0 GHz, ≤0.25 dB @ 3.0 to 5.0 GHz, ≤0.5 dB @ 5.0 to 7.0 GHz

≤1.1:1 DC to 2.0 GHz, ≤1.2:1 2.0 to 3.0 GHz, ≤1.4:1 3.0 to 7.0 GHz

10 A 20 kA 8/20 µs per IEC 61000-4-5 TNC Female TNC Female GT-TFF-AL

GT-TFM-AL DC to 7.0 GHz1 kW @ 30 MHz, 300 W @ 3 GHz

≤0.1 dB @ DC to 3.0 GHz, ≤0.25 dB @ 3.0 to 5.0 GHz, ≤0.5 dB @ 5.0 to 7.0 GHz

≤1.1:1 DC to 2.0 GHz, ≤1.2:1 2.0 to 3.0 GHz, ≤1.4:1 3.0 to 7.0 GHz

10 A 20 kA 8/20 µs per IEC 61000-4-5 TNC Female TNC Male GT-TFM-AL

DT-NFF DC to 3.0 GHz 40 W @ 30 MHz≤0.1 dB @ DC to 1.0 GHz, ≤0.25 dB @ 1.0 to 3.0 GHz

≤1.1:1 DC to 1.0 GHz 10 A 4 kA 8/20 µs per IEC 61000-4-5 N Female N Female DT-NFF

DT-NFM DC to 3.0 GHz 40 W @ 30 MHz≤0.1 dB @ DC to 1.0 GHz, ≤0.25 dB @ 1.0 to 3.0 GHz

≤1.1:1 DC to 1.0 GHz, ≤1.15:1 DC to 3.0 GHz

10 A 4 kA 8/20 µs per IEC 61000-4-5 N Female N Male DT-NFM

Page 52: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Coaxial RF Surge Protection52

• 3, 5 and 8 port earthed entrance panels

• Building entry panels

Features

5PEEP-M

Single point grounding is the most important part of any lightning protection system. PolyPhaser entry establishes a single point grounding solution. Whether you have a thick wall, thin wall, or multiple lines, PolyPhaser provides both panels and accessories to support all grounding requirements.

Grounding and Accessories

Grounding

Wall Thickness # of Ports Max. Cable Diameter

3PEEP > 8” 3 3.13”

5PB-M 10” 5 3.13”

5PEEP-M > 8” 5 3.13”

8PB-M 10” 8 3.13”

8PEEP-M > 8” 8 3.13”

5PEEP-M

Page 53: Protection Technology Group USA_CATALOG_2011-2012

53

• Shield grounding kits

• Copper grounding kits

• Clamps

• Copper straps

• Adaptors

Options for Accessories

PolyPhaser offers a full line of accessories needed to complete any professional single point grounding project.

Accessories

Grounding Clamp Product Description Application

58R-112S Bonding Clamp Copper Strap Clamp

J-1 Transition Clamp for 0.5” to 1.33” diameter Wire/copper rod transition clamp

J-2 Transition Clamp for 1.5” to 2.25” diameter Wire/copper rod transition clamp

Grounding Kit Product Description Application

CCK Kit, Copper Cleaning Copper Cleaning Kit

CU-SPGP Copper Single Point Ground Panel Grounding Plate 16” on center

Device Ground Adaptor

Product Description Application

GSA-KIT-N Kit, Ground Strap Adaptor N connector Ground Strap Adaptor SX Series

Copper Grounding Strap

Width Length

CS112-25 1.5” 25’

CS112-50 1.5” 50’

CS112-100 1.5” 100’

CS3-25 3” 25’

CS3-50 3” 50’

CS3-100 3” 100’

CS6-25 6” 25’

CS6-50 6” 50’

CS6-100 6” 100’

Coaxial Shield Grounding Kit

Shield Diameter Shield Material Grounding to

UNI-KIT-4CC 2.125” to 4” Copper or Brass Aluminum, Tin or Galvanized

UNI-KIT-4CT 2.125” to 4” Copper or Brass Copper or Brass

UNI-KIT-4TC 2.125” to 4” Aluminum, Tin or Galvanized Aluminum, Tin or Galvanized

58R-112S

CCK

GSA-KIT-N

CS Series

UNI-KIT-4CC

J-2

CU-SPGP

Page 54: Protection Technology Group USA_CATALOG_2011-2012

55

End to end data line protection solutions are available in both custom as well as commercial

off-the-shelf products for digital and analog signals in both indoor and outdoor enclosures.

Page 55: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Data Line Surge Protection 56

• Low capacitance (3 pF) high surge current capacity (20 kA)

• Compact 1 RU modular chassis fits up to 16 modules

• Fused options satisfy GR-1089-CORE Issue 4 EIPP installation requirements

• Coordinated Level I & Level II lightning protection

• Front access, modular for multi-protocol installations: 10/100 Ethernet, GbE and T1/E1

• Dual lug grounding studs

Features

• GR-1089-CORE Issue 4

• UL 497A (fused)

• UL 497B (non-fused)

• IEEE 802.3

• ITU 703

Standards and Certificates

1101-977

High density, modular, multi-protocol, coordinated Level I and Level II surge protection for OSP environments.

Multi-Protocol Equipment Protector

CPX Series

Page 56: Protection Technology Group USA_CATALOG_2011-2012

57

Input/Output Connector RJ-45

Chassis Dimensions (H x W x D) in

1.75 x 19.0 x 3.3

Chassis Dimensions (H x W x D) cm

4.5 x 48.3 x 8.4

Chassis Weight (max) lb, kg

3.0, 1.36

Module Weight (max) lb, kg

0.1, 0.05

Humidity 99% non-condensing

Operating/Storage Temperature

-40°C to +75°C

Protocol Ethernet T1/E1 Gigabit Ethernet

Data Rate 10 / 100 Mb/s 1.544 / 2.048 Mb/s 10 / 100 / 1000 Mb/s

Pins Protected (1, 2) and (3, 6) (1, 2) and (4, 5) (1, 2), (3, 6), (4, 5) and (7, 8)

Pins Bonded to Ground (4, 5) and (7, 8) (3, 6) and (7, 8) n / a

Nominal Voltage 5 Vdc 3.3 Vdc 5 Vdc

Max Continuous Operating Voltage

< 11 Vpk

Max Continuous Operating Amperage

< 180 mA

Max Surge Current 20 kA 8/20 µs per Level II GR 1089-CORE Issue 4, port type 3 & 5 surge

Mechanical

Environmental

Electrical

Part Name 10/100BTFused

10/100BTNon-Fused

T1/E1Fused

T1/E1Non-Fused

GbEFused

GbENon-Fused

Module 1000-1268 1000-1268-NF 1000-1269 1000-1269-NF 1000-1270 1000-1270-NF

16 Port Chassis 1101-984 1101-974 1101-986 1101-976 1101-985 1101-975

8 Port Chassis 1101-987 1101-977 1101-989 1101-979 1101-988 1101-978

Page 57: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Data Line Surge Protection 58

• Easy installation with ground stud and RJ-45 jacks

• High surge current capacity

Features

• UL 497B Listed

• RoHS compliant

Standards and Certificates

1101-994

Compact data line surge protection for T1, gigabit PoE, GbE, PoE and Ethernet with 48 Vdc power.

Multi-Protocol Equipment Protector

TSJ Series

Page 58: Protection Technology Group USA_CATALOG_2011-2012

59

Input/Output Connector Shielded RJ-45 Shielded RJ-45 Shielded RJ-45 Shielded RJ-45 Non-shielded RJ-45

Max Dimensions (H x W x D) in

3.2 x 2.2 x 1.7

Max Dimensions (H x W x D) cm

8.1 x 5.6 x 4.3

Weight (max) lb, kg 0.2, 0.1

Humidity 99% non-condensing

Operating/Storage Temperature

-40°C to +85°C

Enclosure Rating UL 94V-0

Application Gigabit PoE Gigabit PoE 56 Ethernet 48 CLT

Data Rate 1000 Mb/s 1000 Mb/s 10/100 Mb/s 10/100 Mb/s 1.44/2.048 Mb/s

Pins Protected All pins L-L and L-G 1, 2, 3, 6 1, 2, 4, 5

Nominal Voltage 48 Vdc 5 Vdc 48 Vdc 5 Vdc 12 Vdc

Max Continuous Operating Voltage

56 Vdc 11 Vdc 56 Vdc 11 Vdc 12 Vdc

Max Surge Current 10/1000 µs per Telecordia GR 1089

1 kA L-L, L-G 500 A L-L, L-G 100 A L-L, L-G 500 A L-L, L-G 100 A L-L, L-G

Max Surge Current 8/20 µs per IEC 6100-4-5

20 kA L-L, L-G 5 kA L-L, L-G 1.5 kA L-L, L-G 5 kA L-L, L-G 2.5 kA L-L

Mechanical

Environmental

Electrical

Part Name TSJ GbE PoE TSJ GbE TSJ POE 56 TSJ 10/100 TSJ 48 CLT

Part Number 1101-994 1101-990 1101-991 1101-1001 1101-300-1

Page 59: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Data Line Surge Protection 60

• Non-degradable, low clamping silicon diode suppression technology (except 1101-911)

• Line and load bidirectional protection

• 1RU chassis holds up to 16 modules and is adjustable to fit 19” or 23” racks

• Unprotected pins bonded to ground

Features

• GR-1089

• NEC 800.100 and 830.100

• IEEE 802.3af

• ITU 703

Standards and Certificates

1000-1206

Modular, reconfigurable, rack, wall or DIN rail mount surge protection for PoE, GbE, Ethernet, T1/E1 and xDSL.

Multi-Protocol Equipment Protector

DPR (Data Protection Rack)

Page 60: Protection Technology Group USA_CATALOG_2011-2012

61

Input/Output Connector RJ-45

Module Dimensions (H x W x D) in

1.0 x 1.0 x 3.7

Module Dimensions (H x W x D) cm

2.5 x 2.5 x 9.4

Chassis Dimensions (H x W x D) in

1.8 x 19.0 x 3.7

Chassis Dimensions (H x W x D) cm

4.4 x 48.3 x 9.4

Module Weight (max) lb, kg

1.5, 0.7

Chassis Weight (max) lb, kg

5.2, 2.4

Humidity 99% non-condensing

Operating/Storage Temperature

-40°C to +75°C

Enclosure Rating UL 94V-0

Protocol Ethernet T1/E1 xDSL GbE PoE GbE / PoE

Data Rate 10/100 Mb/s 1.544/2.048 Mb/s 6.312 Mb/s 10/100/1000 Mb/s 10/100 Mb/s 10/100/1000 Mb/s

Pins Protected(1,2) (3,6) (4,5) and (7,8)

(1,2) and (4,5) (1,2) and (4,5)(1,2) (3,6) (4,5) and (7,8)

(1,2) (3,6) (4,5) and (7,8)

(1,2) (3,6) (4,5) and (7,8)

Nominal Voltage 5 Vpk 3 Vpk 3 Vpk 3.3 Vpk 48 Vpk 60 Vpk

Max Continuous Operating Voltage

6Vpk 6 Vpk 5.5 Vpk 6 Vpk 60 Vpk 75 Vpk

Surge Suppression<25 Vpk @ 100 A 10/1000 µs

<25 Vpk @ 100 A / 10/1000 µs

<25 Vpk @ 100 A / 10/1000 µs

<22Vpk @ 100 A / 2/10µs

<75Vpk @ 100 A / 10/1000µs

<100 Vpk @ 100 A / 10/1000 µs

Mechanical

Environmental

Electrical

Part Name DPR Ethernet DPR T1/E1 DPR XDSL DPR 1000 Base T DPR POE 60 V DPR GT

Part Number 1101-828 1101-830 1101-829 1101-882 1101-905 1101-911

Page 61: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

62 Data Line Surge Protection

• Non-degradable, low clamping silicon diode protection

• Line and load bidirectional protection

• External ground lug

• 6 individual circuits

• Easy to install

• Unprotected pins bonded to ground

• Replacement modules available

Features

• GR 1089 CORE

Standards and Certificates

1101-995

Six port data line protector for T1/E1 and Ethernet applications.

Multi-Protocol Equipment Protector

TSJ X6 Series

Input/Output Connector RJ-45 (unshielded) RJ-45 (shielded) RJ-45 (shielded)

Enclosure Dimensions (H x W x D) in

5.3 x 5.7 x 1.2

Enclosure Dimensions (H x W x D) cm

13.5 x 14.5 x 3.0

Weight (max) lb, kg 0.5, 0.2

Application T1/E1 Ethernet Gigabit Ethernet

Data Rate 1.44/2.048 Mb/s 10/100 Mb/s 1000 Mb/s

Pins ProtectedData (1, 2) and (4, 5)

Data (1, 2) and (3,6 )

(1, 2)(4,5)(3,6) and (7,8)

Nominal Voltage 3 Vpk 5 Vpk 3.3 V

MCOV Data 12 Vpk 12 Vpk 11 Vpk

Voltage Protection Level <26 Vpk @ 100 A 10/1000 µs

Max Surge Current 100 A @ 10/1000 µs500 A @ 8/20 μs, 100 A @ 10/1000 µs

5 kA @ 8/20 μs, 100 A @ 10/1000 µs

Mechanical

Environmental

Electrical

Part Name TSJ X6A TSJ 10/100 TSJ X6 GbE

Part Number 1101-772-A 1101-995 1101-1044

Humidity 99% non-condensing

Operating/Storage Temperature

-40°C to +85°C

Enclosure Rating UL94V-0

Page 62: Protection Technology Group USA_CATALOG_2011-2012

Data Line Surge Protection

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Data Line Surge Protection 63

• High surge current capacity

• Optimized for signal throughput

Features

• IEC 6100-4-5

• Telecordia GR 1089

• IEEE 802.3

Standards and Certificates

1101-1028

Outdoor, RJ-45, bulkhead mount, IP 67, surge protector for 10/100 Mb/s PoE, gigabit Ethernet and gigabit PoE.

Multi-Protocol Equipment Protector

TB (Thunderbolt) Series

Input/Output Connector RJ-45

Enclosure Dimensions (H x W x D) in

1.5 x 1.5 x 4.0

Enclosure Dimensions (H x W x D) cm

3.6 x 3.6 x 10.0

Weight (lb, kg) 0.2, 0.1

Application PoE Gigabit Ethernet Gigabit PoE

Data Rate 10/100 Mb/s 1000 Mb/s 1000 Mb/s

Pins Protected Data (1, 2) and (3 ,6), DC power (4, 5) and (7, 8)

(1, 2), (3 ,6), (4, 5) and (7, 8)

(1, 2), (3 ,6), (4, 5) and (7, 8)

Nominal Voltage 48 Vdc 3.3 Vdc 48 Vdc

Max Continuous Operating Voltage

90 Vpk (pins 4, 5, 7, 8)11 Vpk (pins 1, 2, 3, 6)

11 Vpk 90 Vpk

Max Surge Current 5 kA 8/20 µs

Mechanical

Environmental

Electrical

Part Name TB 10/100/PoE TB GbE TB GbE PoE

Part Number 1101-1028 1101-1029 1101-1030

Humidity 99% non-condensing

Operating/Storage Temperature

-40°C to +75°C

Enclosure Rating IP 67

Page 63: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Data Line Surge Protection 64

• Non-degradable, quick response silicon diode technology

• Optimized for point-to-point and point-to-multipoint radios

• Line and load bidirectional protection

• UL 497 protection from powerline cross, sneak current and over voltage (1101-640)

• ALPU Pole Mounting Kit (1000-1164)

Features

• UL 497

• IEEE/ANSI C62.41

Standards and Certificates

1101-640

Gigabit Ethernet and Power over Ethernet pole-mountable lightning protection.

Multi-Protocol Equipment Protector

ALPU Series

Page 64: Protection Technology Group USA_CATALOG_2011-2012

65

Input/Output Connector IDC punch down block (10 pair) RJ-45 and screw terminal IDC punch down block (8 pair)

Enclosure Dimensions (H x W x D) in

7.3 x 4.7 x 2.5

Enclosure Dimensions (H x W x D) cm

18.4 x 11.9 x 6.4

Weight (max) lb, kg 1.7, 0.8

Humidity 99% non-condensing

Operating/Storage Temperature

-40°C to +85°C

Enclosure Rating UL 94-V5 / NEMA 3R

Protocol Ethernet, PoE Ethernet, PoE GbE, PoE

Data Rate 100 Mb/s 100 Mb/s 1000 Mb/s

Pins Protected(1, 2), (3, 6), (4, 5) and (7, 8) + reset wire and LED signal wire

Data (1, 2), (3, 6), DC (4, 5) (7, 8) (1, 2), (3, 6), (4, 5) and (7, 8)

Nominal Voltage 55 Vdc Data 6 Vdc, DC 48 Vdc 55 Vdc

Max Continuous Operating Voltage

90 Vpk Data 13 Vdc, DC 60 Vdc 94 Vpk pins (1, 2) and (3, 6) and 99 Vdc pins (4, 5) and (7, 8)

Voltage Protection Level<130 Vpk @ 150 A 10/1000 µs, 152 Vpk 1.5 kA 8/20 µs

21.5 Vpk on data and 86 Vpk on DC pairs @ 27 Vpk on data and 108 Vpk on DC pairs @ 2.5 kA 8/20 µs

152 Vpk @ 1.5 kA8/20 µs

Max Surge Current 1.5 kA 8/20 µs, 150 A 10/1000 µs 2.5 kA 8/20 µs, 200 A 10/1000 µs 120 A 10/1000 µs

Mechanical

Environmental

Electrical

Part Name ALPU ALVR ALPU-TSU ALPU-ORT

Part Number 1101-640 1101-656 1101-778

Page 65: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Data Line Surge Protection66

• DC modules optimized to 12, 24, 48, 56 or 72 Vdc

• Data line modules optimized for POTS, Telco Trunk, T1/E1, RS-232, RS-422, RS-485 Ethernet or PoE

• Weatherized enclosure

• Available with isolated ground

• SMCP-OD pair configuration available

• Boards available in bags of 50

• Pole mount kit offered

Features

Part Number Matrix

• UL 497 B

• GR-1089

• RoHS compliant

Standards and Certificates

IX-2H2DC48

Configurable, modular, weatherized, twisted pair surge protection for up to five pairs.

Multi-Protocol Equipment Protector

IX Series

Board Application Turn on Voltage

SeriesImpedance

Capacitance(Differential)

Capacitance(Common)

H Cat5, UTP, STP +9 Vdc ±10% I ohm ±20% 30 pF Typical 15 pF Typical

L T1/E1, RS4223, RS485

± 12 Typical I ohm ±20% 100 pF Typical 100 pF Typical

M RS232 ± 31 Typical I ohm ±20% 100 pF Typical 100 pF Typical

N PoE ±64 Typical I ohm ±20% 50 pF Typical 50 pF Typical

P POTS/ext Lines ± 110 Typical I ohm ±20% 40 pF Typical 40 pF Typical

TRing Voltage, DSL, ADSL, HDSL

± 210 Typical I ohm ±20% 30 pF Typical 30 pF Typical

DC 12 12 Vdc Power +18 Vdc ±10% 0.05 ohm ±20% N/A N/A

DC 24 24 Vdc Power +33 Vdc ±10% 0.05 ohm ±20% N/A N/A

DC 48 48 Vdc Power +56 Vdc ±10% 0.05 ohm ±20% N/A N/A

DC 56 56 Vdc Power +68 Vdc ±10% 0.05 ohm ±20% N/A N/A

DC 72 72 Vdc Power +82 Vdc ±10% 0.05 ohm ±20% N/A N/A

DC 12-IG 12 Vdc Power +18 Vdc ±10% 0.05 ohm ±20% N/A N/A

DC 24-IG 24 Vdc Power +33 Vdc ±10% 0.05 ohm ±20% N/A N/A

DC 48-IG 48 Vdc Power +56 Vdc ±10% 0.05 ohm ±20% N/A N/A

DC 56-IG 56 Vdc Power +68 Vdc ±10% 0.05 ohm ±20% N/A N/A

DC 72-IG 72 Vdc Power +82 Vdc ±10% 0.05 ohm ±20% N/A N/A

Mechanical

Input/Output Connector 28 to 16 AWG terminal screw

Dimensions (H x W x D) in 5.3 x 2.5 x 1.7

Dimensions (H x W x D) cm 13.3 x 6.4 x 4.3

Weight (max) lb, kg 0.7, 0.4

Environmental

Operating Temperature -40°C to +65°C

Note: If not using either power or data boards, simply drop them from the part number

Isolated groundVoltage of power boardPower board designatorNumber of power boardsType of data boardsNumber of data boardsSeries designator

IX - 2 H 1 DC 48 - IG

Page 66: Protection Technology Group USA_CATALOG_2011-2012

Data Line Surge Protection 67

IX Series

Model Name/Number IX-1T IX-2H1DC56-IG IX-2H1DC24-IG IX-2H1DC48-IG IX-2L IX-2T

Application xDSL PoE PoE PoET1/E1 or RS-422/RS-485

Dual Telco Trunk

Data Rate Up to 25 Mb/s 10/100 Mb/s 10/100 Mb/s 10/100 Mb/s Up to 25 Mb/s Up to 25 Mb/s

Data Turn On @ 10 mA ±210 Vdc±9 Vdc ±10% per board

±9 Vdc ±10% ±9 Vdc ±10% ±12 Vdc ±10 % ±210 Vdc ±10 %

Data Series Resistance 1.0 Ohm ±2%

Data Voltage Protection 100 Vdc/sec

< ±260 Vdc < ±9.6 Vdc < ±9.6 Vdc < ±9.6 Vdc < ±13 Vdc < 260 Vdc

DC Nominal Voltage N/A ±56 Vdc ±24 Vdc ±48 Vdc N/A N/A

DC Turn On @ 2 A N/A ±68 Vdc ±10 % ±33 Vdc ±10 % ±56 Vdc ±10 % N/A N/A

DC Voltage Protection 100 Vdc/sec

N/A < ±75 Vdc < ±34 Vdc < ±58 Vdc N/A N/A

DC Series Resistance 0.05 Ohms ±2%

Max Surge Current 100 A @10/1000 µs per Telecordia GR-1089

Page 67: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Data Line Surge Protection 68

• UL 94V-0 flame rated plastic and aluminum enclosures available

• Compact design

• 1/4-20 ground stud

Features

• GR-1089

• NEC 800.100 and 830.100

• IEEE 802.3af

• CE

• RoHS compliant

Standards and Certificates

1101-873

Compact, outdoor, RJ-45, Power over Ethernet surge protection for point-to-point and point-to-multi-point radios.

PoE Protector

ALPU POE Series

Page 68: Protection Technology Group USA_CATALOG_2011-2012

69

Input/Output Connector RJ-45 shielded 100 Ohm

Dimensions (H x W x D) in 7.2 x 3.0 x 1.7 6.7 x 3.7 x 1.7 7.2 x 3.0 x 1.7 6.7 x 3.7 x 1.7 7.2 x 3.0 x 1.7 6.7 x 3.7 x 1.7

Dimensions (H x W x D) cm 18.2 x 7.7 x 4.2 17.1 x 9.4 x 4.2 18.2 x 7.7 x 4.2 17.1 x 9.4 x 4.2 18.2 x 7.7 x 4.2 17.1 x 9.4 x 4.2

Weight (max) lb, kg 0.8, 0.4 0.5, 0.2 0.8, 0.4 0.5, 0.2 0.8, 0.4 0.5, 0.2

Humidity 99% non-condensing

Operating/Storage Temperature

-40°C to +80°C

Protocol Power over Ethernet

Data Rate 100 Mb/s

Pins Protected Data (1,2) and (3,6), DC power (4,5) and (7,8)

Data Nominal Voltage 5 Vpk 5 Vpk 48 Vpk 48 Vpk 75 Vpk 75 Vpk

DC Nominal Voltage 48 Vdc 48 Vdc 48 Vdc 48 Vdc 75 Vdc 75 Vdc

MCOV Data 6 Vpk 6 Vpk 48 Vpk 48 Vpk 75 Vpk 75 Vpk

MCOV DC Power 60 Vpk 60 Vpk 48 Vpk 48 Vpk 75 Vpk 75 Vpk

Data Voltage Protection Level

< 25 Vpk @ 100 A 10/1000 μs < 75 Vpk @ 100 A 10/1000 μs < 150 Vpk @ 100 A 10/1000 μs

DC Power Voltage Protection Level

< 75 Vpk @ 100 A 10/1000 μs < 75 Vpk @ 100 A 10/1000 μs < 150 Vpk @ 100 A 10/1000 μs

Impedance 85 to 115 Ohms

Mechanical

Environmental

Electrical

Part Name ALPU-POE-06-M ALPU-POE-06 ALPU-POE-60-M ALPU-POE-60 ALPU-POE-90-M ALPU-POE-90

Part Number 1101-932 1101-873 1101-933 1101-897 1101-934 1101-898

Enlosure Material Cast Aluminum Plastic Cast Aluminum Plastic Cast Aluminum Plastic

Page 69: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

70 Data Line Surge Protection

• High surge current capacity

• Ideal for Motorola canopy systems with 8 PoE lines

Features

• IEC 6100-4-5

• GR 1089 CORE

• IEEE 802.3

Standards and Certificates

1101-805

Eight port, outdoor, PoE protector with RJ-45 connectors.

PoE Protector

ALPU CMM3

Input/Output Connector RJ-45 Shielded

Enclosure Dimensions in (H x W x D )

17.0 x 11.0 x 6.0

Enclosure Dimensions cm (H x W x D )

43.0 x 28.0 x 15.0

Weight (max) lb, kg 7.0, 3.2

Data Rate 10/100 Mb/s

Pins Protected (1, 2), (3, 6), (4, 5) and (7, 8)

Max Continuous Operating Voltage 90 Vpk

Max Surge Current 800 A 8/20 µs, 200 A 10/1000 µs

Mechanical

Environmental

Electrical

Part Name ALPU CMM3

Part Number 1101-805

Humidity 90% non-condensing

Operating/Storage Temperature -20°C to +65°C

Enclosure Rating UL 1863

Page 70: Protection Technology Group USA_CATALOG_2011-2012

Data Line Surge Protection

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Data Line Surge Protection 71

• Non-degradable, low clamping, leadless silicon diode protection

• Line and load bidirectional protection

• Functions as bridge clip

• Ground bar (1101-621)

Features

• Bellcore 1089

Standards and Certificates

1101-115

Data line surge protection for 66 punch down block applications.

Punch Down Block Protector

PBM Series

Input/Output Connector 66 punch down block - IDC (replaces bridge clip)

Enclosure Dimensions in (H x W x D )

1.8 x 0.9 x 0.4

Enclosure Dimensions cm (H x W x D )

4.5 x 2.3 x 0.9

Weight (max) lb, kg 0.1, 0.05

Application Telco Trunk T1 (1 pair of wires)

Nominal Voltage 230 V 40 V

Max Continuous Operating Voltage

270 Vpk 45 Vpk

Max Surge Current 100 A @ 10/1000 µs,150 A @ 8/20 µs

100 A @ 10/1000 µs,150 A @ 8/20 µs

Mechanical

Environmental

Electrical

Part Name PBM 6605 PBM 6607

Part Number 1101-115 1101-162

Operating/Storage Temperature

-20°C to +50°C

Page 71: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Data Line Surge Protection 72

• Non degradable, low clamping, leadless, silicon avalanche diode

• Line and load bidirectional protection

• Optimized for RS422, RS485 and 4-20mA loops

• Protects up to two balanced pairs and shields

• Shield is pass-through

Features

FSP 4001 MC1101-372-1

High-speed, high-current, silicon avalanche data line surge protector designed for RS422, RS485 and 4-20mA loops double wire pair equipment. Product family can accomodate 12 Vdc, 27 Vdc, 52 Vdc and 280 Vdc service voltage applications.

Two-Pair Signal Protector

FSP 4000 MC Series

Page 72: Protection Technology Group USA_CATALOG_2011-2012

73

Suppression Terminal Input and output clamping screw terminal 14-4 AWG (25 mm2 max)

Dimensions (H x W x D) in 3.2 x 2.2 x 1.4

Dimensions (H x W x D) cm 5.6 x 8.1 x 3.6

Weight (max) lb, g 0.2, 73

Humidity 90% non-condensing

Operating Temperature -40°C to +65°C

Enclosure Rating 94 V5

Service Voltage 12 Vdc 27 Vdc 52 Vdc 280 Vdc

Max Continuous Operating Voltage 13 Vpk 27 Vpk 54 Vpk 290 Vpk

Voltage Protection Level 50 V 65 V 100 V <500 V @ 10 kA 8/20 µs

Max Surge Current Rating 10/1000 μs 200 A 134 A 67 A 21.4 A

Configuration 2 balanced pairs + 2 shields

Input Connection Terminal block

Connector Positions 6 in 6 out

Protection Modes L-L, L-G

Response Time < 5 ns

Mechanical

Environmental

Electrical

Part Name FSP 4001 MC FSP 4002 MC FSP 4003 MC FSP 4005 MC-GT

Part Number 1101-372-1 1101-372-2 1101-372-3 1101-372-6

Page 73: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Data Line Surge Protection 74

• Non-degradable, low clamping, leadless silicon diode protection

• Line and load bidirectional protection

• BNC connectors for video and protection circuit for RS-232/RS-422/RS-485

• 22 to 16 AWG screw terminal for DC circuit protection

Features

• IEEE/ANSI C62.41

• UL 497B Listed CCTV configured (1101-607)

Standards and Certificates

1101-607

Data line and DC surge protection for pan-tilt-zoom surveillance systems with power and signal circuits.

CCTV Equipment Protector

CCTV Series

Page 74: Protection Technology Group USA_CATALOG_2011-2012

75

Input/Output Connector BNC female in and out, two (in/out) five position screw terminals

Enclosure Dimensions (H x W x D) in 3.2 x 3.2 x 1.7

Enclosure Dimensions (H x W x D) cm

8.1 x 8.1 x 4.3

Weight (max) lb, kg 0.2, 0.1

Application Triple circuit protector for coax, 24 V AC/DC and RS-232/RS-422/RS-485

Triple circuit protector for coax, and two pairs RS-232/RS-422/RS-485

MCOV Signal 12 Vdc tip to ring, 40 Vdc ring to ground

Max Surge Current Signal 140 A 10/1000 µs

MCOV Data 24 Vdc

Max Surge Current Data 190 A 10/1000 µs

MCOV AC/DC 28 Vac, 40 Vdc n/a

Max Surge Current DC 150 A 10/1000 µs n/a

Mechanical

Environmental

Electrical

Part Name CCTV-PTZ CCTV-PTZ-4

Part Number 1101-607 1101-613

Operating/Storage Temperature

-40°C to +65°C

Enclosure Rating UL94-VO

Page 75: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

76 Data Line Surge ProtectionData Line Surge Protection

• Non-degradable, low clamping, leadless silicon diode protection

• Line and load bidirectional protection

• Mounts on standard 19 inch racks

• Low capacitance design, less than 20 pF

• CCTV 75 ohm application

Features

• IEEE/ANSI C62.41

Standards and Certificates

1101-704

High-speed, high-current, solid state silicon device designed to protect (16) CCTV lines.

CCTV Equipment Protector

RMP - CCTV

Input/Output Connector 75 ohm, BNC female

Enclosure Dimensions in (H x W x D )

3.5 x 19.0 x 1.2

Enclosure Dimensions cm (H x W x D )

8.9 x 48.3 x 2.9

Weight (max) lb, kg 2.3, 1.1

Protection Modes Signal to Return, Signal/Return to GND

Max Continuous Operating Voltage 7.5 Vpk

Max Surge Current 1800 A 8/20 µs, 286 A 10/1000 µs

Mechanical

Environmental

Electrical

Part Name RMP CCTV 16

Part Number 1101-704

Operating/Storage Temperature -30°C to +65°C

Page 76: Protection Technology Group USA_CATALOG_2011-2012

Data Line Surge Protection

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Data Line Surge Protection 77Data Line Surge Protection

Part Name RMP CCTV 16

Part Number 1101-704

• High surge current capacity

• Flange mount

• CCTV application

Features

• IEC 1000-4-5

Standards and Certificates

IS-75BB/1.5

75 Ohm baseband unit that passes 1.5 Vdc for use in network LAN or video operations.

CCTV Equipment Protector

IS-75BB

Input/Output Connector BNC female

Enclosure Dimensions in (H x W x D )

5.1 x 2.3 x 1.4

Enclosure Dimensions cm (H x W x D )

12.9 x 5.7 x 3.4

Weight (max) lb, kg 0.5, 0.2

Nominal Voltage ±1.5 Vdc 18 Vdc

Turn On Voltage ±2.3 Vdc 19 Vdc

Frequency Range DC to 30 MHz

Current 3 A continuous

Max Surge Current 18 kA per IEC 61000-4-5 8/20 µs

Insertion Loss ≤0.3 dB

Impedance 75 ohm

Mechanical

Environmental

Electrical

Part Name/Number IS-75BB/1.5 IS-75BB/18

Operating/Storage Temperature

-45°C to +45°C

Page 77: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

78 Data Line Surge ProtectionData Line Surge Protection

• Engineered for RF and telemetry performance

• High surge current capacity

Features

• IEC 6100-4-5

Standards and Certificates

MDS+24-F-F

Flange mount, 75 ohm surge protection with telemetry and F female connector for satellite systems.

Satellite Equipment Protector

MDS

Input/Output Connector F female

Enclosure Dimensions in (H x W x D )

3.3 x 2.2 x 1.5

Enclosure Dimensions cm (H x W x D )

8.4 x 5.5 x 3.7

Weight (max) lb, kg 0.5, 0.2

RF Frequency Range 300 MHz to 2.5 GHz

RF Power 50 W

Telemetry Frequency Range 10 kHz to 150 kHz and 10 MHz to 100 MHz

Telemetry Operating Voltage 24 Vdc

Max Surge Current 3 kA 8/20 µs, 3 kA 10/350 µs

Impedance 75 ohm

Mechanical

Environmental

Electrical

Part Name/Number MDS+24-F-F

Humidity 100% non-condensing

Operating/Storage Temperature -50°C to +90°C

Operating Vibration/Shock ETS 300 019-2-4, Class 4M3

Page 78: Protection Technology Group USA_CATALOG_2011-2012

Data Line Surge Protection

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Data Line Surge Protection 79Data Line Surge Protection

• Rugged gas tube, SASD hybrid circuit

• Fits single or dual conduit ports

• 1/2” NPT thread for series or “T” conduit attachment

Features

• Telecordia GR 1089

• FM Approval Class I Division II

• EX

• CE

Standards and Certificates

1101-587

Submersible, low voltage, low frequency, signal surge protection with 18 AWG leads for series wiring.

Submersible Signal Protector

PDS Series

Input/Output Connector 16 AWG leads (1.5 mm2)

Enclosure Dimensions (in) 0.5” diameter, 5.0” length

Enclosure Dimensions (cm) 1.3 diameter x 12.7 length

Weight (max) lb, kg 0.1, 0.05

Max Continuous Operating Voltage

< 28 Vpk

Voltage Protection Level 8/20 µs @ 3 kA 6 kV

~ 125 Vpk @ L-L, L-G

Voltage Protection Level 8/20 µs @ 10 kA 20 kV

~ 250 Vpk @ L-L, L-G

Voltage Protection Level 10/1000 µs @ 100 A

~ 250 Vpk @ L-L, L-G

Max Surge Current 10 kA @ 20 kV 8/20 µs

Parasitic Capacitance 8 pF L-L

Mechanical

Environmental

Electrical

Part Name PDS1 - Parallel Conduit “T” Branch

PDS2 - Series Installed Conduit

Part Number 1101-586 1101-587

Operating/Storage Temperature

-40°C to +65°C

Page 79: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Data Line Surge Protection 80

• Illuminated and remote (dry contact relay) status indication

• Easy installation; 24 to 18 AWG cage clamp

• Modular - replace suppressor module without disconnecting circuit

• Non-degradable, fast acting silicon diode surge suppression

• DIN rail mounted

Features

• FM approval Class I Division II

• CE

Standards and Certificates

1101-869

Modular, single or dual twisted pair 28 to 12 AWG, data line surge protection for AC and DC circuits with visual indication of suppressor status for circuits with power applied.

Data/Power Equipment Protector

DRI Series

Page 80: Protection Technology Group USA_CATALOG_2011-2012

81

Input/Output Connector Cage clamp 28 to 12 AWG

Enclosure Dimensions in (H x W x D )

3.4 x 2.9 x 1.4

Enclosure Dimensions cm (H x W x D )

8.6 x 7.4 x 3.6

Weight (max) lb, kg 0.3, 0.2

Data Rate DC to 30 kb/s

Nominal Voltage 170 Vdc (120 Vac) 24 Vdc

Max Continuous Operating Voltage

180 Vpk 34 Vpk

Indicating Electrical Service 110 to 125 Vac

Voltage Protection Level 8/20 µs

<310 Vpk @ 1000 A <110 Vpk @ 1000 A

Voltage Protection Level 10/1000 µs

<250 Vpk @ 85 A <48 Vpk @ 100 A

Max Surge Current 1 kA 10/1000 µs

Mechanical

Environmental

Electrical

Part Name DRI 120 DRI 24

Part Number 1101-870 1101-869

Humidity 99% non-condensing

Operating/Storage Temperature

-40°C to +85°C

Enclosure Rating 94V-0

Page 81: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Data Line Surge Protection 82

• Non-degradable, low clamping, leadless silicon diode protection

• Line and load bidirectional protection

• Gas discharge tube back-up protection

• Visual status indication

Features

• ANSI/IEEE C62.45

• IEEE C62.41

• AREMA

Standards and Certificates

1101-707

The SXRR series suppressors are high-speed, high-current solid state silicon devices that are designed to provide equalization protection for railroad signaling and Positive Train Control (PTC) applications.

Railroad Equipment Protector

SXRR Series

Input/Output Connector 1/4 inch terminal clips

Enclosure Dimensions (H x W x D) in

2.1 x 2.9 x 1.0

Enclosure Dimensions (H x W x D) cm

5.3 x 7.4 x 2.5

Weight (max) lb, kg 0.1, 0.05

Operating/Storage Temperature

-40°C to +75°C

Enclosure Rating UL 94V-0

Nominal Voltage 12 V 90 V 120 V

Max Continous Operating Voltage

35 Vac, 50 Vdc 110 Vdc 130 Vac

Voltage Protection Level290 Vpk @ 20 kA 8/20 µs

340 Vpk @ 20 kA 8/20 µs

450 Vpk @ 20 kA 8/20 µs

Max Surge Current 20 kA @ 8/20 µs

Mechanical

Environmental

Electrical

Part Name SXRR 50 SXRR 90 SXRR 120

Part Number 1101-707 1101-744 1101-764

Page 82: Protection Technology Group USA_CATALOG_2011-2012

83

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Smart Surge Recorder

1104-09-001

DIN Transient Surge Monitor and Counter

A smart surge recorder used to monitor and capture the number and time of transient surges.

I2R SSR

Enclosure Dimensions (H x W x D) in 3.6 x 1.4 x 2.6

Enclosure Dimensions (H x W x D) cm

9.1 x 3.7 x 6.7

Weight (max) lb, kg 0.24, 0.11

Sensitivity Level 1 kA - 3 kA counting (8/20 µs)

Visual Indication LCD

Estimated Lifespan 8 years

Mechanical

Environmental

Electrical

Part Name I2R SSR

Part Number 1104-09-001

Relative Humidity 95% non-condensing

Operating Temperature 0°C to +70°C

• Transient incident record of number and date (up to 80 records)

• Long lasting lithium battery

• Low energy consumption (at dormant state)

• Easy installation

• DIN rail mount

Features

Page 83: Protection Technology Group USA_CATALOG_2011-2012

85

Our AC surge protection product offering leads the industry with silicon

diode and MOV protection options available in AC panel, integrated power

distribution cabinets, self-contained enclosures, modular DIN rail, and rack

mount configurations.

Page 84: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

AC Surge Protection86

• Hybrid silicon diode/MOV design or MOV only

• Visual and remote status monitoring

• Line and load bidirectional protection

• Thermally protected MOV

• Replacement modules

• Outdoor enclosure

• Motorola R-56 approved

Features

• UL 1449 3rd Edition

• ANSI/IEEE C62.45

• IEEE C62.412002 C High

Standards and Certificates

1101-808

1101-809-M

Modular, 160 kA per phase, hybrid panel surge protector with remote and visual status monitoring in outdoor enclosure.

Panel Protector

IMAX Series

Page 85: Protection Technology Group USA_CATALOG_2011-2012

87

Max Dimensions (H x W x D) in

12.5 x 10.5 x 6.6 12.5 x 10.5 x 6.6 12.0 x 10.0 x 8.0 12.5 x 10.5 x 6.6 12.5 x 10.5 x 6.6 12.0 x 10.0 x 8.0

Max Dimensions (H x W x D) cm

31.8 x 26.7 x 16.7 31.8 x 26.7 x 16.7 31.8 x 25.4 x 20.3 31.8 x 26.7 x 16.7 31.8 x 26.7 x 16.7 31.8 x 25.4 x 20.3

Weight (max) lb, kg 14.0, 6.5 14.0 , 6.5 24.0, 10.9 14.0, 6.5 14.0, 6.5 24.0, 10.9

Humidity 100% non-condensing

Operating/Storage Temperature

-40°C to +75°C

Enclosure Rating NEMA 4X NEMA 4X NEMA 12 metal NEMA 4X NEMA 4X NEMA 12 metal

Technology Silicon / MOV Silicon / MOV Silicon / MOV MOV MOV MOV

Voltage Configuration120/240 split phase

120/208 3-phase wye

120/208 3-phase wye

120/240 split phase

120/208 3-phase wye

120/208 3-phase wye

Max Continuous Operating Voltage

138 Vac L-N

Imax 160 kA @ 4 kV 8/20 µs per IEC 61643-1 Class II

Fault Current Rating 65 kAIC per NEC 285.6

Mechanical

Environmental

Electrical

Part Name/Number 1101-808 1101-809 1101-809-M 1101-808-MM 1101-809-MM 1101-809-M-MM

Page 86: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

AC Surge Protection88

Terminal TypeWiring lugs sized for 6 AWG to 1/0 AWG (16 mm2 to 50 mm2)

Status Indication Terminal C/NC/NO 22 to 14 AWG rated 15 A/300 Vdc (250 Vac)

Dimensions (H x W x D) in 12.5 x 10.5 x 6.6

Dimensions (H x W x D) cm 31.8 x 26.7 x 16.7

Weight (max) lb, kg 10.5, 4.8

Humidity 95% non-condensing

Operating Temperature -40°C to +65°C

Enclosure Rating NEMA 4X/CSA Type 4, IP 66

Technology Silicon Silicon/MOV Silicon/MOV

Voltage Configuration240/415 Vac 3-phase wye

120/240 Vac split phase

120/208 Vac 3-phase wye

Max Continuous Operating Voltage 276/477 Vrms 138/276 Vrms 138 Vrms

Max Surge Current 8/20 μs10 kA per phase

10 kA silicon/ 30 kA MOV per phase

10 kA silicon/ 30 kA MOV per phase

Fault Current Rating 65 kAIC

Mechanical

Environmental

Electrical

Part Name APEX IV X5 240WI

APEX IV X5 120TMR

APEX IV X5 120WMR

Part Number 1101-446-43 1101-460 1101-464

1101-460

Robust, high surge current capacity AC panel surge protection with visual and remote status indication per phase in outdoor enclosure.

Panel Protector

APEX IV Series

• Non-degradable, low clamping silicon diode suppression with robust, high surge current capacity MOV

• Visual and remote status monitoring

• Line and load bidirectional protection

• Thermally protected MOV

• Plug-in modules

• Outdoor enclosure

Features

• UL 1449 3rd Edition (1101-460, 1101-464)

Standards and Certificates

Page 87: Protection Technology Group USA_CATALOG_2011-2012

AC Surge Protection

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

AC Surge Protection 89

Terminal Type Wiring lugs sized for 6 AWG to 1/0 AWG (16 mm2 to 50 mm2)

Status Indication Terminal C/NC/NO 22 to 14 AWG rated 15 A/300 Vdc (250 Vac)

Dimensions (H x W x D) in 12.5 x 10.5 x 6.6

Dimensions (H x W x D) cm 31.8 x 26.7 x 16.7

Weight (max) lb, kg 10.5, 4.8

Humidity 95% non-condensing

Operating Temperature -40°C to +65°C

Enclosure Rating NEMA 4X

Voltage Configuration 120/240 Vac split phase 120/208 Vac 3-phase wye

Max Continuous Operating Voltage 150 Vrms

Voltage Protection Level 8/20 μs 800 Vpk @ 500/6 kV

Max Surge Current 8/20 μs 30 kA per phase

Mechanical

Environmental

Electrical

Part Name APEX 120TR MOV APEX 120WMR MOV

Part Number 1101-338 1101-546

1101-338

Robust, high surge current capacity AC panel surge protection with visual and remote status indication per phase in outdoor enclosure.

Panel Protector

APEX MOV

• Visual and remote status indication (dry relay contacts) per phase

• Robust, high surge current capacity MOV technology

• Line and load bidirectional protection

• Easy to remove, plug-in modules

Features

Page 88: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

AC Surge Protection90

• Non-degradable, low clamping silicon diode suppression with robust, high surge current capacity MOV

• Visual and remote status indication per phase

• Line and load bidirectional protection

• Surge counter (1101-771)

Features

• IEEE C62.41

• IEC 61643-1

• NEMA 4X enclosure

Standards and Certificates

1101-424

Low clamping, high surge current capacity AC panel surge protection with visual and remote status indication per phase in outdoor enclosure.

Panel Protector - Outdoor

MCP-OD Series

Page 89: Protection Technology Group USA_CATALOG_2011-2012

91

Terminal Type Three 10 AWG (6 mm2) Three 10 AWG (6 mm2) Four 10 AWG (6 mm2) Four 10 AWG (6 mm2)

Status Indication Terminal

18 AWG (1.2 mm) three pin euro style DC pluggable terminal block C/NC/NO

Dimensions(H x W x D) in

11.0 x 9.0 x 6.2 11.0 x 9.0 x 6.2 11.0 x 9.0 x 6.2 13.0 x 10.5 x 6.5

Dimensions(H x W x D) cm

27.9 x 22.9 x 15.9 27.9 x 22.9 x 15.9 27.9 x 22.9 x 15.9 33.0 x 26.7 x 16.5

Weight (max) lb, kg 5.8, 2.6 5.8, 2.6 5.8, 2.6 7.5, 2.9

Technology Silicon / MOV MOV Silicon / MOV Silicon / MOV

Voltage Configuration 120/240 Vac split phase 120/240 Vac split phase 120/208 Vac 3-phase wye 120/208 Vac 3-phase wye

Max Continuous Operating Voltage

140/280 Vrms 160 Vrms 160 Vrms 160 Vrms

Turn on Voltage 230 Vpk @ 5 mA

Voltage Protection Level 8/20 µs

330 Vpk L-N @ 500 A

Max Surge Current 8/20 µs

10 kA 200 kA 100 kA 10 kA /100 kA

IEEE Rating C High

Humidity 95% non-condensing

Operating/Storage Temperature

-40°C to +65°C

Enclosure Rating UL 94-5V

Mechanical

Environmental

Electrical

Part Name MCP 120TA-10M-OD MCP-MOV 120TA-200K-OD MCP 120W SASD/MOV-ODMCP 120W SASD/MOV-OD-COUNTER

Part Number 1101-424 1101-645 1101-738 1101-771

Page 90: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

92 AC Surge Protection

• Audible alarm with disable switch

• Surge counter – counts suppressed transients

• Visual and remote status indication (dry relay contacts) per phase

• Robust, thermally protected MOV technology

• EMI/RFI noise filtering

• Modular per mode

• All mode protection - L-N, L-G, N-G & L-L

• Available with or without disconnect

Features

• UL 1449 3rd Edition

• NEC

• IEEE

• CBEMA/ITIC

• NEMA LS

• Article 100/285

Standards and Certificates

PV Plus

Robust, modular, UL 1449 3rd Edition surge protection device with up to 600 kA of surge current capacity per phase.

Panel Protector

PV Plus Series

Page 91: Protection Technology Group USA_CATALOG_2011-2012

AC Surge Protection 93

Dimensions(H x W x D) in

24.0 x 16.0 x 8.9

Dimensions(H x W x D) cm

61.0 x 41.0 x 22.4

Weight (max) lb, kg 60, 27

Voltage Configuration 120/240 Vac split phase, 120/208 3-phase wye, 277/480 3-phase wye, 480 delta

Max Surge Current per Phase 8/20 µs

200 kA 400 kA 600 kA

Max Surge Current per Mode 8/20 µs

100 kA 200 kA 300 kA

Nominal Discharge Current Rating (In)

20 kA per phase

Fault Rating (SCCR) 100 kAIC

Operating Frequency 47-63 Hz

IEEE Location C-High

UL Location Type 2

Humidity 95% non-condensing

Operating/Storage Temperature

-40°C to +65°C

Enclosure Rating NEMA 3R

Operating Altitude 12,000 feet above sea level

Mechanical

Environmental

Electrical

Part Name PV 200 PV 400 PV 600

Contact 1.800.882.9110 or visit www.protectiongroup.com for product configuration support.

Page 92: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

94 AC Surge Protection

LS 100

Compact, modular, thermally protected surge protection device.

Panel Protector

LS Plus

• Visual status indication per phase

• Remote status indication (dry relay contacts)

• Audible alarm with disable switch

• Surge counter for suppressed transients

• Robust, thermally protected MOV technology

• All mode protection - L-N, L-G, N-G & L-L

Features

• UL 1449 3rd Edition

• NEC

• IEEE

• CBEMA/ITIC

• NEMA LS

• NEC Article 100/285

Standards and Certificates

Page 93: Protection Technology Group USA_CATALOG_2011-2012

AC Surge Protection 95

Terminal Type #14 - 4 AWG (25 mm2 max)

Dimensions (H x W x D) in 14.0 x 12.0 x 6.0 20.0 x 16.0 x 7.0 20.0 x 16.0 x 7.0

Dimensions (H x W x D) cm 35.6 x 30.5 x 15.2 50.8 x 40.6 x 17.8 50.8 x 40.6 x 17.8

Status Indication Terminal #22 - #14 AWG

Weight (max) lb, kg 30.0, 13.6 32.0, 14.6 35.0, 15.9

Humidity 95% non-condensing

Operating/Storage Temperature -40° C to +60° C

Enclosure Rating NEMA 3R

Voltage Configuration 120/240 V split phase, 120/208 V 3-phase wye, 277/480 V 3-phase wye

Max Surge Current Per Phase 8/20µs 100 kA 200 kA 300 kA

Max Surge Current Per Mode 8/20µs 50 kA L-G, L-N, N-G, L-L 100 kA L-N, N-G, L-G, L-L 150 kA L-N, L-L, L-G, N-G

Nominal Discharge Current Rating (In) 20 kA per phase

Fault Rating (SCCR) 100 kAIC

Mechanical

Environmental

Electrical

Part Name LS Plus LS Plus LS Plus

Part Number LS 100 LS 200 LS 300

Contact 1.800.882.9110 or visit www.protectiongroup.com for product configuration support.

Page 94: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

96 AC Surge Protection

SP200

SP100

Robust, modular, UL 1449 3rd Edition surge protection device with up to 200 kA of surge current capacity per phase.

Panel Protector

SP Plus Series

• Visual status indication per phase

• Remote status indication (dry relay contacts)

• Audible alarm with optional disable switch

• Robust, thermally protected MOV technology

• EMI/RFI noise filtering

• All mode protection - L-N, L-G, N-G & L-L

Features

• UL 1449 3rd Edition

• NEC Article 285

Standards and Certificates

Page 95: Protection Technology Group USA_CATALOG_2011-2012

AC Surge Protection 97

Terminal Type # 10 AWG leads (6 mm2)

Dimensions (H x W x D) in 6.3 x 6.3 x 3.5 9.5 x 6.3 x 3.5

Dimensions (H x W x D) cm 16.0 x 16.0 x 8.9 24.1 x 16.0 x 8.9

Weight (max) lb, kg 3, 1.4 5, 2.3

Humidity 95% non-condensing

Operating/Storage Temperature -40° C to +60° C

Enclosure Rating NEMA 4 (NEMA 1 w/disable switch option)

Voltage Configuration 120/240 V split phase, 120/208 V 3-phase wye, 277/480 V 3-phase wye, 480 V delta (SP 200 only)

Max Surge Current Per Phase 8/20µs 100 kA 200 kA

Max Surge Current Per Mode 8/20µs 50 kA 100 kA

Nominal Discharge Current Rating (In) 8/20µs

Up to 20 kA Up to 20 kA

Fault Rating (SCCR) 100 kAIC 100 kAIC

Mechanical

Environmental

Electrical

Part Name SP Plus SP Plus

Part Number SP 100 SP 200

Contact 1.800.882.9110 or visit www.protectiongroup.com for product configuration support.

Page 96: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

98 AC Surge Protection

• Non-degradable, low clamping silicon diode suppression with robust, high surge current capacity MOV patented linear-sharing Wagon Wheel technology

• Incorporated LC filter for superior protection

• Also available in international voltage configurations

• Remote status monitor

Features

DS21 Model

DS30 Model

Series connected, modular, hybrid silicon avalanche diode with coordinated, robust MOV technology for high lightning exposure environments.

Panel Protector

Dyna System Series

• NEMA 12 standard

Standards and Certificates

Page 97: Protection Technology Group USA_CATALOG_2011-2012

AC Surge Protection 99

Dimensions (H x W x D) in

18.9 x 14.4 x 7.9 48.0 x 24.0 x 8.8 30.0 x 24.0 x 8.8 48.0 x 36.0 x 10.0 60.0 x 36.0 x 13.2 72.0 x 36.0 x 13.2

Dimensions (H x W x D) cm

48.0 x 36.6 x 20.1 122.0 x 61.0 x 23.0 76.0 x 61.0 x 23.0 122.0 x 92.0 x 26.0 152.4 x 91.4 x 33.5 182.9 x 91.4 x 33.5

Weight (max) lb, kg 40.0, 18.1 80.0, 36.3 80.0, 36.3 530.0, 240.0 495.0, 225.0 950.0, 431.0

Humidity 95% non-condensing

Operating/Storage Temperature

-40°C to +65°C

Enclosure Rating NEMA 12 Standard

Voltage Configuration Options

120/240 Vac split phase, 120/208 3-phase wye, 277/480 3-phase wye, 480 delta, 230 D, 220/380, 240/415

Nominal Amperage 80 A 150 A 225 A 300 A 600 A 1200 A

Max Surge Current Per Phase 8/20µs

225 kA @ 6 kV 225 kA @ 6 kV 225 kA @ 6 kV 225 kA @ 6 kV 337.5 kA @ 6 kV 337.5 kA @ 6 kV

Max Surge Current Per Mode 8/20µs

L-N: 112.5 kA L-N, 225 kA L-L, 225 kA L-G, 112.5 kA N-G @ 6 kV

Filter Component 1 µH coil 1 µH coil 1 µH coil 100 µH coil Triax 100 µH coil Triax 100 µH coil Triax

Mechanical

Environmental

Electrical

Part Name DS 21 DS 21 DS 21 DS 20 DS 30 DS 30

Part Number DS21-80A DS21-150A DS21-225A DS20-300A DS30-600A DS30-1200A

Call 1.800.654.8087 or visit www.protectiongroup.com for product configuration support.

Page 98: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

AC Surge Protection100

• Visual and remote (dry contact relay) status indication

• High surge current capacity, ≤40 kA per phase

Features

1101-980

Modular, compact 120 Vac and 240 Vac single phase, silicon diode, DIN rail surge protection with visual and remote status indication.

Panel Protector

I2R CDS Series

Page 99: Protection Technology Group USA_CATALOG_2011-2012

101

Terminal Type 10 AWG leads (6 mm2) 10 AWG leads (6 mm2) 10 AWG leads (6 mm2)

Max Dimensions (H x W x D) in

8.7 x 8.1 x 5.6 8.5 x 6.5 x 4.5 6.5 x 5.5 x 4.0

Max Dimensions (H x W x D) cm

22.1 x 20.6 x 14.0 22.2 x 16.6 x 11.5 16.6 x 14.0 x 10.2

Status Indication Terminal Form C dry relay contacts, 0.5 A/ 75 Vdc, 0.1 A/250 Vdc, 0.5 A/250 Vac, 22 to 14 AWG (2 mm maximum)

Humidity 100% non-condensing 100% non-condensing 90% non-condensing

Operating/Storage Temperature

-40°C to +85°C

Enclosure Rating NEMA 3R

Voltage Configuration 120/240 Vac Split Phase 120/240 Vac Split Phase 120/208 Vac 3-phase wye

Max Continuous Operating Voltage

145 Vrms L-N 145 Vrms L-N 150 Vrms L-N, 300 Vrms L-L

Voltage Protection Level 400 Vpk @ 3 kA 6 kV 8/20 µs L-N 590 Vpk @ 3 kA 6 kV 8/20 µs L-N 330 Vpk @ 500 A 6 kV 8/20 µs L-N

Max Surge Current 45 kA per phase 8/20 µs 40 kA per phase 8/20 µs 40 kA per phase 8/20 µs

Mechanical

Environmental

Electrical

Part Name I2R 120/240 RR I2R 120/240 MMRR MCP 120W BM

Part Number 1101-980 1101-981 1101-872

Page 100: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

AC Surge Protection102

• Robust, high surge current capacity

• MOV linear sharing technology

• Flush mount option available

Features

Robust, compact, 120 kA surge current capacity per phase surge protection.

Panel Protector

CFS Series

Terminal Type #10 AWG leads (6 mm2)

Max Dimensions (H x W x D) in

5.2 x 5.2 x 2.5

Max Dimensions (H x W x D) cm

13.3 x 13.3 x 6.4

Weight (max) lb, kg 5, 2.3

Humidity 95% non-condensing

Operating/Storage Temperature

-40°C to +65°C

Enclosure Rating NEMA 4X

Voltage Configuration Available

120/240 Vac split phase, 120/208 3-phase wye, 277/480 3-phase wye, 120/240 CPGD, 480-D, 240 single phase

Max Surge Current per Phase

120 kA 8/20 µs per phase

Max Surge Current per Mode

60 kA L-N, L-L, & L-G 8/20 µs

Mechanical

Environmental

Electrical

Part Name CFS

Part Number A70-00-5006, A70-00-5007, A70-00-5008, A70-00-5010, A70-00-5011, A70-00-5002

Contact 1.800.882.9110 or visit www.protectiongroup.com for product configuration support.

A70-00-5007

Page 101: Protection Technology Group USA_CATALOG_2011-2012

AC Surge Protection

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

103AC Surge Protection

• Non degradable, low clamping silicon diode suppression

• RJ-11 jack for dial-up phone protection

• Visual status indication

• 6 foot power cord with NEMA 5-15 swivel prong plug

• Eight NEMA 5-15 receptacles

Features

• IEEE C62.41

Standards and Certificates

1102-007-1A

120 Vac, 15 A, plug-in, eight receptacle silicon diode surge protector.

Plug-In Protector

DPS Series

Plug Type NEMA 5-15

Receptacle Type Eight NEMA 5-15

Max Dimensions (H x W x D) in

3.6 x 9.5 x 1.5

Max Dimensions (H x W x D) cm

9.1 x 24.1 x 3.8

Weight (max) lb, kg 1.5, 0.7

Humidity 95% non-condensing

Operating/Storage Temperature

-40°C to +65°C

Voltage Configuration 120 Vac single phase

Max Surge Current 1 kA @ 8/20 µs

Mechanical

Environmental

Electrical

Part Name DPS 8T SASD (GRAY CASE)

Part Number 1102-007-1A

Page 102: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

AC Surge Protection104

• Non-degradable, low clamping, leadless silicon diode protection

• Illuminated status indication

• Bi-polar, bi-directional protection

Features

SL 120 Series1104-29-000

The SL Series AC surge protectors are a solid-state SASD (Silicon Avalanche Suppressor Diode) device designed to protect electronic equipment and systems from transient overvoltages on 120 Vac single phase services. The SL Series offers continuous bi-polar, bi-directional, non-interrupting protection.

Plug-In Protector

SL Series

Page 103: Protection Technology Group USA_CATALOG_2011-2012

105

Enclosure PA66, UL94 V-O

Enclosure Dimensions (H x W x D) in 2.9 x 2.8 x 2.4

Enclosure Dimensions (H x W x D) cm

7.5 x 7.2 x 6.1

Weight (max) lb, kg 0.3, 0.1

Nominal Operating Voltage 120 V, 50/60 Hz (L-N)

Maximum Continuous Operating Voltage 150 V, 50/60 Hz (L-N)

Maximum Discharge Current 5 kA (L-N)

Voltage Protrection Level 500 V @ 6 kV, 3 kA

Status Indication GREEN - SPD functioningRED - Power continues to be supplied to load

GREEN - SPD functioningRED - Power removed from load

Mechanical

Environmental

Electrical

Part Name SL 120 SLN 120

Part Number 1104-29-000 1104-29-001

Relative Humidity 95% non-condensing

Operating/Storage Temperature -40°C to +70°C

Enclosure Rating IP20

Page 104: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

AC Surge Protection106

• Non-degradable, low clamping silicon diode suppression

• Illuminated status indication

• Compact 1RU

• NEMA 5-15 and 5-20 rated plugs and receptacles

• Switched outlets (1102-007-9)

Features

• IEEE C62.41

Standards and Certificates

1102-007-9

120 Vac single phase, multiple outlet, 19” rack mount, silicon diode surge protection.

Plug-In Protector

RMP Series

Page 105: Protection Technology Group USA_CATALOG_2011-2012

107

Plug Type NEMA 5-15 Dual NEMA 5-20 (twist lock) NEMA 5-20

Receptacle Type Six NEMA 5-15 Eight NEMA 5-20 (4 per input) Nine NEMA 5-20

Max Dimensions (H x W x D) in

1.8 x 19.0 x 3.5 1.8 x 19.0 x 4.8 1.8 x 19.0 x 4.8

Max Dimensions (H x W x D) cm

4.6 x 48.3 x 8.9 4.6 x 48.3 x 11.5 4.6 x 48.3 x 11.5

Weight (max) lb, kg 4.5, 2.1 9.0, 4.1 9.0, 4.1

Humidity 95% non-condensing

Operating/Storage Temperature

-40°C to +65°C

Voltage Configuration 120 Vac single phase

Nominal Amperage 15 A (fused) 20 A 20 A

Max Surge Current 3 kA 8/20 µs 3 kA 8/20 µs 1.5 kA 8/20 µs

Mechanical

Environmental

Electrical

Part Name RMP 615A RMP2 420A RMP 920A

Part Number 1101-534 1101-560 1102-007-9

Page 106: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

AC Surge Protection108

• Non-degradable, low clamping silicon diode suppression with robust, high surge current capacity MOV technology

• Visual and remote status indication per phase

• Line and load bidirectional protection

Features

• IEEE C62.41

• IEC 61643-1

• UL 1449 3rd Edition (1101-299)

Standards and Certificates

Low clamping, high surge current capacity AC component surge protection with visual and remote status indication per phase.

Component Protector

MCP Series

1101-299

Page 107: Protection Technology Group USA_CATALOG_2011-2012

109

Terminal Type Three 10 AWG (6 mm2) wire leads Three 10 AWG (6 mm2) wire leads Four 10 AWG (6 mm2) wire leads

Status Indication Terminal

18 AWG (1.2 mm2) three pin, removable, terminal block C/NC/NO

Max Dimensions (H x W x D) in

6.6 x 4.2 x 3.3

Max Dimensions (H x W x D) cm

16.8 x 10.6 x 8.3

Weight (max) lb, kg 2.5, 1.1

Humidity 95% non-condensing

Operating/Storage Temperature

-40°C to +65°C

Enclosure Rating UL 94V-0

Nominal Operating Voltage

120/240 Vac split phase 120/240 Vac split phase 120/208 Vac 3-phase wye

Max Continuous Operating Voltage

138/267 Vrms

Mechanical

Environmental

Electrical

Part Name MCP 120TA-10M MCP 120TA-20M MCP 120W SASD/MOV

Part Number 1101-299 1101-689 1101-732

Page 108: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

AC Surge Protection110

• Illuminated status indication

• Non-degradable, low clamping silicon diode suppression

• Line and load bidirectional protection

• DIN rail mount with remote status monitoring (1101-739)

• Fused outputs (1100-739, 1100-954)

Features

• IEEE C62.41

Standards and Certificates

1100-629

Hardwired, compact, silicon, 120 Vac single phase surge protection.

Component Protector

ACP 100 Series

Page 109: Protection Technology Group USA_CATALOG_2011-2012

111

Terminal or Plug TypeFour position terminal strip

Four position terminal strip

Four position terminal strip

24 to 10 AWG screw terminal

6 inch 14 AWG leads

Max Dimensions (H x W x D) in

6.3 x 3.4 x 2.4 6.3 x 3.4 x 2.4 6.3 x 3.4 x 2.4 6.5 x 3.0 x 2.5 2.2 x 3.2 x 1.7

Max Dimensions (H x W x D) cm

15.9 x 8.6 x 6.0 15.9 x 8.6 x 6.0 15.9 x 8.6 x 6.0 16.6 x 7.7 x 6.4 5.6 x 8.2 x 4.3

Weight (max) lb, kg 0.7, 0.3 0.7, 0.3 0.7, 0.3 0.7, 0.3 0.2, 0.1

Humidity 95 % non-condensing

Operating/Storage Temperature

-40°C to +65°C

Enclosure Rating IP 20

Voltage Configuration 120 Vac single phase

Max Continuous Operating Voltage

220 Vrms

Nominal Amperage 10 A 15 A 15 A (fused) 15 A 15 A (fused)

Voltage Protection Level 330 Vpk L-NC 500 A 8/20 µs

Mechanical

Environmental

Electrical

Part Name ACP 100 BW3 ACP 100 BW3R ACP 100 BWN3 ACP 100 DR2 5-15 ACP 100 MN

Part Number 1100-629 1100-855 1100-954 1101-608 1100-647

Page 110: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

AC Surge Protection112

• Compact, high surge current capacity, non-degrading silicon diode

• High current activated MOV sharing circuit

• Visual and remote (dry contact relay) status indication

• Line and load bidirectional protection

• Overload disconnect per phase

• IP65 enclosure (1101-901)

Features

• IEC 61643-1 Class I and Class II

Standards and Certificates

1101-826

240 and 240/415, hybrid silicon diode with combined MOV, hardwired, Class I and Class II IEC surge suppressor with remote monitoring.

Component Protector

SuperHy Series

Page 111: Protection Technology Group USA_CATALOG_2011-2012

113

Wire Size (max) 16 mm2 (stranded), 25 mm2 (solid) #6 to #4 AWG

Max Dimensions (H x W x D) in

3.6 x 2.2 x 2.7 8.7 x 10.9 x 5.4

Max Dimensions (H x W x D) cm

9.1 x 5.5 x 6.8 22.0 x 27.6 x 13.6

Weight (max) lb, kg 0.7, 0.3 6.2, 2.8

Humidity 90% non-condensing

Operating/Storage Temperature

-40°C to +80°C

Voltage Configuration 240 Vac single phase 240/415 Vac 3 phase w/ NPE

Nominal Operating Voltage (Un)

230 V 50/60 Hz

Max Continuous Operating Voltage (Uc)

320 V 50/60 Hz

Impulse Current (Iimp) 20 kA @ 10/350 µs

Nominal Discharge Current (In)

20 kA @ 8/20 µs

Max Discharge Current (Imax) 120 kA @ 8/20 µs

Voltage Protection Level (Up)

1.2 kV @ 8/20 µs

Mechanical

Environmental

Electrical

Part Name SuperHy 240 SuperHy 240W CM Enclosure

Part Number 1101-826 1101-901

Page 112: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

AC Surge Protection114

• Non-degrading, low clamping, leadless silicon diode protection

• LED status indication

• Line and load bidirectional protection

• DIN or screw mounting

Features

• IEEE C62.41

• UL 1449 3rd Edition (1101-627)

Standards and Certificates

1101-627

Modular, 120 Vac and 240 Vac single phase, silicon diode, DIN rail surge protection with visual status indication.

Component Protector

I2R ICP Series

Terminal Type Screw Terminal 14 to 4 AWG (2.5 mm2 to 25 mm2)

Max Dimensions (H x W x D) in

2.7 x 1.0 x 2.7

Max Dimensions (H x W x D) cm

6.9 x 2.5 x 6.9

Weight (max) lb, kg 0.4, 0.2

Humidity 95% non-condensing

Operating/Storage Temperature

-40°C to +80°C

Norminal Operating Voltage 120 Vac single phase 240 Vac single phase

Max Continuous Operating Voltage

138 Vrms 280 Vrms

Voltage Protection Rating 500 Vpk @ 3 kA 8/20 µs N/A

Voltage Protection Level N/A 600 Vpk @ 500A 8/20µs

Max Surge Current 7 kA @ 8/20 µs

Mechanical

Environmental

Electrical

Part Name 120 V SASD 240 V SASD

Part Number 1101-627 1101-629

Page 113: Protection Technology Group USA_CATALOG_2011-2012

AC Surge Protection

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

AC Surge Protection 115

Component Protector

DIN rail mountable 120 Vac surge protection device (SPD) that offers high performance silicon avalanche suppression diode (SASD) technology protection.

I2R IEP 120-10

Maximum Wire Size 16 mm2 (stranded) - 25 mm2 (solid) #6 to #4 AWG

Location Category Indoor only, Type 1

Enclosure Dimensions in (H x W x D )

3.5 x 1.4 x 2.4

Enclosure Dimensions cm (H x W x D )

8.9 x 3.6 x 6.1

Weight (max) lb, kg 0.26, 0.12

Nominal Operating Voltage (Un) 150 Vac

Nominal Discharge Current (In) (8/20µs) 5 kA

Maximum Discharge Current (Imax) (8/20µs) 10 kA

Voltage Protection Level (Up) (8/20µs) 600 V

Leakage Current (Ur) <5 µA

Mechanical

Environmental

Electrical

Part Name I2R IEP 120-10

Part Number 1104-15-000

Relative Humidity 95% non-condensing

Operating/Storage Temperature -40°C to +80°C

Enclosure Rating IP20 (IEC EN 60529)

• Silicon diode surge protection

• Replaceable modules

• DIN rail mount

• Visual and remote status indication

Features

• IEC 61643-1

• RoHS compliant

Standards and Certificates

1104-15-000

Page 114: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

AC Surge Protection116

• Visual and remote (dry relay contact) status indication

• DIN rail mounted

Features

• IEEE C62.41

• RoHS compliant

Standards and Certificates

1104-15-001

The I2R Storm is a DIN rail mountable, 120 Vac, surge protection device that offers high performance silicon avalanche suppression diode (SASD) technology protection.

Component Protector

I2R Storm Series

Maximum Wire Size 16 mm2 (stranded) - 25 mm2 (solid) #6 to #4 AWG

Location Category Indoor only, Type 1

Enclosure Dimensions (H x W x D) in

3.5 x 0.7 x 2.4

Enclosure Dimensions (H x W x D) cm

9.0 x 1.8 x 6.1

Weight (max) lb, kg 0.26, 0.12

Max Continuous Operating Voltage (Uc) 150 Vac

Maximum Discharge Current (Imax) 10 kA (Type 4)

Nominal Discharge Current (In) 5 kA

Voltage Protection Level (Up) 600 V @ 8/20 µs

Leakage Current (Ur) <5 µA

Mechanical

Environmental

Electrical

Part Name I2R Storm 120-10

Part Number 1104-15-001

Relative Humidity 95% non-condensing

Operating/Storage Temperature -40°C to +80°C

Enclosure Rating IP 20

Page 115: Protection Technology Group USA_CATALOG_2011-2012

AC Surge Protection

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

AC Surge Protection 117

• RoHS compliant

Standards and Certificates

• High surge current thermally protected MOV

• Visual and remote (dry contact relay) status indication

• DIN rail mount

Features

Component Protector

1104-15-002

DIN rail, class II MOV surge protection device for 120 Vac with pluggable modules.

I2R SA 120-50M

Maximum Wire Size 16 mm2 (stranded) - 25 mm2 (solid) #6 to #4 AWG

Location Category Indoor only, Type 2

Enclosure Dimensions (H x W x D) in

3.5 x 0.7 x 2.6

Enclosure Dimensions (H x W x D) cm

9.0 x 1.8 x 6.7

Weight (max) lb, kg 0.2, 0.1

Voltage Configuration 120 Vac single phase

Max Continuous Operating Voltage (Uc) 180 Vac

Nominal Discharge Current (In) 20 kA @ 8/20 µs

Maximum Discharge Current (Imax) 50 kA @ 8/20 µs

Leakage Current <10 µA

Voltage Protection Level (Up) 700 V

Mechanical

Environmental

Electrical

Part Name I2R SA 120-50M(Modular)

Part Number 1104-15-002

Relative Humidity 95% non-condensing

Operating Temperature -40°C to +80°C

IP Rating IP 20

Page 116: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

AC Surge Protection118

• Visual and remote (dry relay contact) status indication

• DIN rail mount

• Rugged, compact and easy to install

Features

• IEC 61643-1

• UL 1449 3rd Edition (1102-014-42, 1102-014-43)

• CE

• RoHS compliant (1102-014-42, 1102-014-43)

Standards and Certificates

1102-014-43

High surge current capacity, DIN rail mount, AC surge protection.

Component Protector

I2R SA Series

Page 117: Protection Technology Group USA_CATALOG_2011-2012

119

Terminal TypeScrew terminal accepts 14-6 AWG (3.3 mm2 max)

Screw terminal accepts 14-6 AWG (3.3 mm2 max)

Screw terminal accepts up to 4 AWG (25 mm2 max)

Screw terminal accepts up to 4 AWG (25 mm2 max)

Max Dimensions (H x W x D) in

4.1 x 0.8 x 2.7 4.1 x 0.8 x 2.7 3.5 x 0.7 x 2.7 3.5 x 0.7 x 2.7

Max Dimensions (H x W x D) cm

10.4 x 2.0 x 6.9 10.4 x 2.0 x 6.9 9.0 x 1.8 x 6.7 9.0 x 1.8 x 6.7

Status Indication Terminal

Screw terminal accepts up to 16 AWG (1.5 mm2)

Screw terminal accepts up to 16 AWG (1.5 mm2)

Screw terminal accepts up to 10 AWG (6 mm2)

Screw terminal accepts up to 10 AWG (6 mm2)

Weight (max) lb, kg 0.2, 0.1 0.2, 0.1 0.2, 0.1 0.9, 0.4

Humidity 95% non-condensing

Operating Temperature -40°C to +65°C

Enclosure Rating IP 20/UL 94V-0

Voltage Configuration 120 Vac single phase 277 Vac single phase 120 Vac single phase 480 Vac 3-phase delta

Max Continuous Operating Voltage (Uc)

180 Vrms 320 Vrms 170 Vrms 600 Vrms

VPR 500 Vpk @ 3 kA/6 kV 900 Vpk @ 3 kA/6 kV 850 Vpk @ 3 kA/6 kV 850 Vpk @ 3 kA/6 kV

Nominal Discharge Current (In)

20 kA @ 8/20 µs 20 kA @ 8/20 µs 20 kA @ 8/20 µs 20 kA @ 8/20 µs

Max Discharge Current (Imax)

50 kA 8/20 µs 50 kA 8/20 µs 40 kA 8/20 µs 40 kA 8/20 µs

SCRR 200 kA 200 kA 60 kA(ef) 60 kA(ef)

Mechanical

Environmental

Electrical

Part Name I2R SA 120-50 I2R SA 277-50 I2R SA120-40 I2R SA480D-40

Part Number 1102-014-43 1102-014-42 1102-014-13-1 1102-014-26

Page 118: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

AC Surge Protection120

• DIN rail mounted

• Rugged MOV technology

• Visual status indicator

• Electrically isolated Form-C dry contacts with a three pin removable terminal plug

Features

• IEC 61643-1 Class II

• RoHS compliant

• Housing FRNC-UL94 V-O

Standards and Certificates

1102-014-7

The I2R SA 230-40 protector is a RoHS compliant, DIN rail mounted 230 Vac surge suppression device that offers high performance MOV technology protection.

Component Protector

I2R SA 230-40

Maximum Wire Size 16 mm2 (stranded) - 25 mm2 (solid) #6 to #4 AWG

Enclosure Dimensions (H x W x D) in

3.5 x 0.7 x 2.6

Enclosure Dimensions (H x W x D) cm

9.0 x 1.8 x 6.7

Weight (max) lb, kg 0.2, 0.1

Nominal Operating Voltage (Un) 230 V single phase

Max Continuous Operating Voltage (Uc) 320 Vrms

Nominal Discharge Current (In) 20 kA @ 8/20 µs

Maximum Discharge Current (Imax) 40 kA @ 8/20 µs

Voltage Protection Level (Up) < 1.4 kV

Mechanical

Environmental

Electrical

Part Name I2R SA 230-40

Part Number 1102-014-7

Relative Humidity 95% non-condensing

Operating/Storage Temperature -40°C to +80°C

Enclosure Rating IP 20

Page 119: Protection Technology Group USA_CATALOG_2011-2012

AC Surge Protection

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

AC Surge Protection 121

• DIN rail mounted

• Rugged Spark Gap technology

Features

• IEC 61643-1 Class II

• RoHS compliant

Standards and Certificates

Component Protector

1102-014-8

The I2R CM 230-20 is a RoHS compliant, DIN rail mounted surge arrester designed for the protection of sensitive electronic power systems for 230 Vac service applications that require neutral-to-ground suppression.

I2R CM 230-20

Maximum Wire Size 16 mm2 (stranded) - 25 mm2 (solid) #6 to #4 AWG

Enclosure Dimensions (H x W x D) in

3.5 x 0.7 x 2.6

Enclosure Dimensions (H x W x D) cm

9.0 x 1.8 x 6.7

Weight (max) lb, kg 0.2, 0.1

Nominal Operating Voltage (Un) 230 V single phase

Max Continuous Operating Voltage (Uc) 260 Vrms

Nominal Discharge Current (In) 20 kA @ 8/20 µs

Maximum Discharge Current (Imax) 50 kA @ 8/20 µs

Mechanical

Environmental

Electrical

Part Name I2R CM 230-20

Part Number 1102-014-8

Relative Humidity 95% non-condensing

Operating/Storage Temperature -40°C to +80°C

Enclosure Rating IP 20

Page 120: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

AC Surge Protection122

• DIN rail mounted

• Visual and remote (dry relay contact) status indication

• Spark Gap technology

Features

• IEC 61643-1 Class I

• RoHS compliant

• IEC EN60529

Standards and Certificates

1102-014-5

The I2R LA is a RoHS compliant, DIN rail mounted surge arrester designed for the protection of electronic systems.

Component Protector

I2R LA Series

Maximum Wire Size 25 mm2 (stranded) - 35 mm2 (solid) #4 to #2 AWG

Enclosure Dimensions (H x W x D) in 3.6 x 1.4 x 2.7

Enclosure Dimensions (H x W x D) cm

9.0 x 3.6 x 6.8

Weight (max) lb, kg 0.7, 0.3

Nominal Operating Voltage (Un) 230 Vac single phase

Max Continuous Operating Voltage (Uc) 320 Vrms 260 Vrms

Nominal Discharge Current (In) 20 kA @ 8/20 µs

Maximum Discharge Current (Imax) 50 kA @ 8/20 µs 100 kA @ 8/20 µs

Voltage Protection Level (Up) <2.0 kV

Mechanical

Environmental

Electrical

Part Name I2R LA 230-50 I2R LA 230-100

Part Number 1102-014-5 1102-014-6

Relative Humidity 95% non-condensing

Operating/Storage Temperature -40°C to +80°C

Enclosure Rating IP 20

Page 121: Protection Technology Group USA_CATALOG_2011-2012

AC Surge Protection

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

AC Surge Protection 123

• Replaceable module

• DIN rail mount

• Status indicator

• RoHS compliant

• MOV and GDT technology

Features

1104-29-000

Railway Track Circuit Protector

Railway Track Circuit 48 V SPD features visual status indication. The indicator is normally green and turns red if module needs replacement.

I2R RSA 48 3-40

Maximum Wire Size 2.5 mm2 (#14 AWG)

Terminal Type Screw cage clamp

Enclosure Dimensions in (H x W x D )

3.5 x 1.4 x 2.7

Enclosure Dimensions cm (H x W x D )

8.9 x 3.6 x 6.8

Weight (max) lb, kg 0.4, 1.8

Nominal Operating Voltage (Un) 48 Vdc

Max Continuous Operating Voltage (Uc) 60 Vdc

Nominal Discharge Current (In) (8/20µs) 10 kA

Maximum Discharge Current (Imax) (8/20µs) 20 kA

Mechanical

Environmental

Electrical

Part Name I2R RSA 48 3-40

Part Number 1104-04-000

Humidity 95% non-condensing

Operating Temperature -40°C to +70°C

Page 122: Protection Technology Group USA_CATALOG_2011-2012

125

For communications equipment operating on DC power, the Protection Technology Group

offers surge suppressors that incorporate fast acting, superior performance, and high

reliability surge suppression elements.

Page 123: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

DC Surge Protection126

• Non-degradable, low clamping, leadless, silicon diode surge suppression

• Engineered for bidirectional, line and load protection

• Replaceable suppression module, no rewiring required

• Fused to protect equipment from extraordinary surge currents

• Optimized for low frequency data circuits including RS-422, RS-485 and 4-20mA loops

• 2 pair/4 wire 28-12 AWG screws

Features

• IEEE C 62.41

• ANSI C 62.41

• FM Approval Class 1 Division II

• CE

• ATEX EU Directive 94/9/EC

• UL 497B (except DRDC-70)

Standards and Certificates

1101-680

Bidirectional, low clamping silicon diode, DIN rail mounted surge protection for DC power and low frequency data lines operating at up to 10 A.

Component Protector

DRDC Series

Page 124: Protection Technology Group USA_CATALOG_2011-2012

DC Surge Protection 127

Terminal 2 pair/4 wire 28-12 AWG Screw (4 mm2 max)

Dimensions (H x W x D) in 4.0 x 0.5 x 4.0

Dimensions (H x W x D) cm 10.2 x 1.3 x 10.2

Weight (maximum) lb, kg 0.1, 0.2

Humidity 95% non-condensing

Operating Temperature -40°C to +80°C

Nominal Voltage 7 Vdc 12 Vdc 24 Vdc 48 Vdc 70 Vdc

Max Continuous Operating Voltage 13 Vdc 16 Vdc 32 Vdc 64 Vdc 118 Vdc

Max Surge Current 1.4 kA @ 10/1000 μs 1.2 kA @ 10/1000 μs 1.2 kA @ 10/1000 μs 1.2 kA @ 10/1000 μs 600 A @ 10/1000 μs

Voltage Protection Level 10/1000 μsIEEE/ANSI C62.41

20 Vpk @ 164 A 25 Vpk @ 134 A 50 Vpk @ 134 A 100 Vpk @ 134 A 165 Vpk @ 66 A

Voltage Protection Level 8/20 μsIEEE/ANSI C62.41

25 Vpk @ 1.4 kA 30 Vpk @ 1.2 kA 60 Vpk @ 1.2 kA 120 Vpk @ 1.2 kA 185 Vpk @ 600 A

Response Time < 5 ns

Mechanical

Environmental

Electrical

Part Name DRDC 7 DRDC 12 DRDC 24 DRDC 48 DRDC 70

Part Number 1101-678 1101-679 1101-680 1101-681 1101-724

Page 125: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

DC Surge Protection128

1104-11-000

Component Protector

Modular indoor, DIN rail, Class II silicon surge protection device for 12, 24 and 48 Vdc

I2R IEP Series

Maximum Wire Size 16 mm2 (stranded) - 25 mm2 (solid) #6 to #4 AWG

Location Category Indoor only

Enclosure Dimensions (H x W x D) in 3.5 x 0.7 x 2.6

Enclosure Dimensions (H x W x D) cm

9.0 x 1.8 x 6.7

Weight (max) lb, kg 0.23, 0.10

Nominal Operating Voltage (Un) 12 Vdc 24 Vdc 48 Vdc

Max Continuous Operating Voltage (Uc) 14 Vdc 28 Vdc 57 Vdc

Nominal Discharge Current (In) (8/20µs) 5 kA (Class II)

Maximum Discharge Current (Imax) (8/20µs) 2.5 kA

Nominal Discharge Current (Up) (8/20µs) <70 V <83 V <125 V

Leakage Current (Ur) <10 µA

Mechanical

Environmental

Electrical

Part Name I2R IEP 12-5 I2R IEP 24-5 I2R IEP 48-5

Part Number1104-11-000 1104-11-001 1104-11-002

Relative Humidity 95% non-condensing

Operating/Storage Temperature -40°C to +80°C

Enclosure Rating IP20

• Silicon diode surge protection

• Replaceable modules

• DIN rail mount

• Visual and remote status indication

Features

• IEC 61643-1

• RoHS compliant

Standards and Certificates

Page 126: Protection Technology Group USA_CATALOG_2011-2012

DC Surge Protection

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

129DC Surge Protection

• Visual and remote status monitoring

• Engineered for bidirectional line and load protection

• Replaceable suppression module, no rewiring required

• Electrically isolated Form-C dry contacts with a three pin removable terminal plug

• DIN rail mounted

Features

• IEC 61643-1 Class I

• RoHS compliant

• Houseing FRNC-UL94VO

• IEC EN 60529

Standards and Certificates

1102-014-38-2

The I2R SA 48-40 is a RoHS compliant, DIN rail mounted, modular surge suppression device designed for the protection of sensitive DC power systems.

Component Protector

I2R SA Series

Maximum Wire Size 25 mm2 (solid), 16 mm2 (stranded) #6 to #4 AWG

Status Indication Terminal Eurostyle terminal plug

Dimensions (H x W x D) in 3.5 x 0.7 x 2.6 3.5 x 2.1 x 2.6

Dimensions (H x W x D) cm 9.0 x 1.8 x 6.7 9.0 x 4.5 x 6.7

Weight (max) lb, kg 0.2, 0.1 0.7, 0.3

Humidity 95% non-condensing

Operating Temperature -40°C to +80°C

Enclosure Rating IP 20

Nominal Operating Voltage (Un) 48 Vdc single phase 48 Vdc

Max Continuous Operating Voltage (Uc) 75 Vdc 75 Vdc

Max Discharge Current (Imax) 40 kA 8/20 μs 40 kA 8/20 μs

Max Voltage Protection Level (Up) 700 Vpl

Response Time < 25 ns < 25 ns

Mechanical

Environmental

Electrical

Part Name I2R SA 48-40 I2R SA 48 3-40

Part Number 1102-014-38-2 1104-11-005

Page 127: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

DC Surge Protection130

• Non-degrading, low clamping, leadless silicon diode protection

• Illuminated and remote dry contact relay status indication

• Line and load bidirectional protection

• Plug-in suppressor module

• Two pair / four wire protection

Features

• FM Approval Class I Division II

• CE

• ATEX EU Directive 94/9/EC

Standards and Certificates

24 Vdc low power signal, silicon diode, DIN rail equipment surge suppressor with visual status indication. DRI 24 is approved for hazardous locations that require a rating of Class I Division II Groups A, B, C and D.

Component Protector

DRI 24

Dimensions (H x W x D) in 2.9 x 1.7 x 3.4

Dimensions (H x W x D) cm 7.3 x 4.3 x 8.6

Weight (max) lb, kg 0.3, 0.14

Humidity 95% non-condensing

Operating Temperature -40°C to +65°C

Service Voltage 24 Vdc

Signal Rate DC power to 30 Kb/s

Protection Modes L-L, L-G

Protection Level 48 Vpk

Max Continuous Operating Voltage

34 Vpk

Max Pass Through Current 5 A

Response Time 5 ns

Mechanical

Environmental

Electrical

Part Name DRI 24

Part Number 1101-869

1101-869

Page 128: Protection Technology Group USA_CATALOG_2011-2012

DC Surge Protection

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

131DC Surge Protection

• Non-degradable, low clamping, silicon avalanche diode surge suppression

• Visual and remote status monitoring

• Bi-directional, line and load protection

• Bullet style breakers

Features

1101-511

Circuit breaker style silicon surge protection for DC power distribution systems with reverse polarity protection from power cross and inductive swells.

Component Protector

CB Series

Suppression Terminal 10-32 bullet style 10-32 bullet style

Dimensions (H x W x D) in 2.5 x 2.5 x 0.7

Dimensions (H x W x D) cm 6.3 x 6.3 x 1.9

Weight (max) lb, kg 0.3, 0.1

Humidity 95% non-condensing

Operating Temperature -30°C to +65°C

Nominal Voltage + 48 Vdc + 48 Vdc

Max Continuous Operating Voltage 60 Vpk 60 Vpk

Max Surge Current 10/1000 μs 1100 A 380 A

Max Surge Current 8/20 μs 15 kA 3 kA

Voltage Protection Level 10/1000 μs 75 Vdc 150 Vdc

Voltage Protection Level 8/20 μs 75 Vdc 150 Vdc

Response Time < 5 ns < 5 ns

Mechanical

Environmental

Electrical

Part Name CB-48-RD-DW CB-48-RD

Part Number 1101-686 1101-511

Page 129: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

DC Surge Protection132

• MOV technology

• Low let-through voltage

• High surge current capacity

• All mode protection series device

Features

1101-1014

48 Vdc protector that utilizes MOV technology to provide high surge current capacity and low let-through voltage.

Component Protector

3DC48-20 Series

Connection Terminals #6 - #20 AWG (16 mm2 max)

Dimensions(H x W x D) in

3.6 x 6.0 x 2.5

Dimensions(H x W x D) cm

9.1 x 15.2 x 6.4

Weight (max) lb, kg 0.8, 0.3

Operating Temperature -40°C to +65°C

Nominal Operating Voltage

±48 Vdc

Max Continuous Operating Voltage

±60 Vdc

Max Continuous Operating Current

20 A

Surge Capabilities 30 kA 8/20 µs per mode maximum

Protection Modes Pos-Neg, Pos-GND, Neg-GND

Mechanical

Environmental

Electrical

Part Name 3DC48-20

Part Number 1101-1014

Page 130: Protection Technology Group USA_CATALOG_2011-2012

DC Surge Protection

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

133DC Surge Protection

• Non-degradable, low clamping, silicon avalanche diode suppression

• Options available to protect 24 Vdc and 48 Vdc applications

• Outdoor NEMA 3R enclosure

• Three mode protection: supply to return, return to ground and supply to ground

• Shunt protectors that also provide a wired “in-line” input and output lug connectors

• Dry contacts for alarming

Features

1101-1024

The DCOD series of products offer SASD-based technology that provides non-degrading, silicon protection for DC power supplies up to 25 A in an outdoor enclosure.

Outdoor Protector

DCOD Series

Wire Range #8 to #6 AWG (16 mm2 max)

Terminal Torque 10 lb-in

Mounting #8 screws 4” centers

Remote Indication 3 pin No/NC/C contacts

Remote Contact Current Rating 2 A

Dimensions (H x W x D) in 7.2 x 5.9 x 2.5

Dimensions (H x W x D) cm 18.3 x 14.9 x 6.4

Weight (max) lb, kg 1.0, 0.4

Operating Temperature -40°C to +85°C

Nominal Voltage 24 Vdc 24 Vdc 48 Vdc 48 Vdc

Max Continuous Operating Voltage 44 Vdc 44 Vdc 88 Vdc 88 Vdc

Nominal Discharge Current (8/20 µs) 2.5 kA 5 kA 2.5 kA 5 kA

Voltage Protection Level 50 V 50 V 100 V 100 V

Mechanical

Environmental

Electrical

DCOD Series 24-2.5 24-5 48-2.5 48-5

Part Number1101-1024

1101-1026

1101-1025

1101-1027

Page 131: Protection Technology Group USA_CATALOG_2011-2012

135Power Distribution Intro Page

Transtector’s DC Edge™ high amperage, compact, rack mount DC distribution

panels are available with voltage settings and options that support both primary and

secondary power distribution.

Page 132: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

DC Power Distribution Panel136

• Compact 1RU PDU

• High current capability - two 350 A inputs

• Universal voltage

• Front load TFD housing or circuit beaker

• 19” or 23” rack mount

• Front panel alarm status LED and discrete dry relay contacts

Features

• UL 60950, Listed

• NEBS-3V

• RoHS compliant

Standards and Certificates

DC Edge™ II

Compact high-power, high-current, universal voltage (+ 24 Vdc to -48 Vdc) power panel featuring dual-feed 350 A buses for either primary or secondary power distribution.

Primary or Secondary Distribution

DC Edge™ II

Dimensions (H x W x D) in 1.7 x 19.0 x 12.0

Dimensions (H x W x D) cm 4.3 x 48.3 x 30.4

Weight (max) lb, kg 16.5, 7.5

Chassis Ground Single, dual 1/4” - 20 on 5/8” stud centers

Humidity 90% non-condensing

Operating Temperature -40°C to +55°C

Enclosure Rating Indoor UL60950

Part Name/Number DC EDGE 350 DF 4/4 / 1101-900

Input Positions (quantity/type) Dual 3/8” - 16 on 1” stud centers

Operating Voltage Range + 20 to + 60 Vdc

Max Input Current per Feed 350 A

Output Positions per Input Four 1/4” - 20 on 5/8” stud centers

Input Rating 350 A per feed, max

Input Interrupt Device 450 A per feed, max

Max Current per Breaker 100 A, Airpax

Max Current per Fuse 125 A, TLS; 70 A, TPS

Fuse Type TPS and TLS

Monitoring Connection Terminal strip for Dry Form-C contacts

Mechanical

Environmental

Electrical

Page 133: Protection Technology Group USA_CATALOG_2011-2012

DC Power Distribution Panel

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

DC Power Distribution Panel 137

• Compact 1RU PDU

• High current capability - four 100 A inputs

• Universal voltage

• Front load circuit beaker

• 19” or 23” rack mount

• Front panel alarm status LED and discrete dry relay contacts

Features

DC Edge™ III

Compact mid-current, universal voltage (+ 24 Vdc to -48 Vdc) power panel featuring quad-feed 100 A buses for secondary power distribution.

Secondary Distribution

DC Edge™ III

Dimensions (H x W x D) in 1.7 x 19.0 x 12.4

Dimensions (H x W x D) cm 4.4 x 48.3 x 31.5

Weight (max) lb, kg 11.5, 5.2

Chassis Ground Single, dual 1/4” - 20 on 5/8” stud centers

Humidity 90% non-condensing

Operating Temperature -10°C to +65°C

Enclosure Rating Indoor UL60950

Part Name / Number DC EDGE III 200QF 8/8 / 1101-1006

Input Positions (quantity / type) Dual 1/4” - 20 studs on 5/8” centers

Operating Voltage Range + 20 to + 74 Vdc

Max Input current per Feed 100 A

Output Positions per Input Four two-pin, keyed Molex male connectors

Input Rating100 A per feed, max (two inputs per side = A1, A2 and B1, B2)

Input Interrupt Device 125 A per feed, max

Max Current per Breaker 30 A

Monitoring Connection HD-15 pin connectors (two), standard and bay alarms

Mechanical

Environmental

Electrical

Page 134: Protection Technology Group USA_CATALOG_2011-2012

139

Our integrated power protection cabinets provide full functionality for quick site setup, low lead times and

termination of both electrical and communication utility feeds. They include AC, DC and data line surge protection options for indoor and outdoor

communication sites with multiple power sources.

Page 135: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

140

Nominal Operating Voltage

120/240 Vac 120/240 Vac

Ampere Rating 100 A 200 A

Material Heavy gauge aluminum

Finish Powder coat

Dimensions (H x W x D) in 30.0 x 24.0 x 10.0

Dimensions (H x W x D) cm 76.2 x 61.0 x 25.4

Weight (max) lb, kg 65.0, 29.5

Mount Wall or H frame, 4x Ø 0.44” mounting holes

Enclosure Type NEMA 3R

Surge Suppression Silicon diode with MOV secondary, or MOV only

Relative Humidity 100% non-condensing

Operating Temperature -40°C to +75°C

Specifications

• NEMA 3R cabinet enclosure

• Three-point latching system and pad lockable handle

• Integrated surge protection (meets UL 1449 3rd Edition)

• Illuminated power and surge suppression status indication

• Remote status monitoring

• GFCI convenience outlet

• UL 891 listed

Features

• Choice of load center sizes:

• 16 or 24 position for 100 A

• 24 position for 200 A

• Mechanically interlocked main breakers

• Numerous configurations available

• Choice of auxillary power connections:

• Appleton AR20044-RS

• Side Mounted Cam-Lok® connectors

Options

AC power protection cabinet suitable for service entrance applications.

Outdoor Cabinet

Compact, Power Protection Cabinet

Model 100 A 200 A

Part Number 1101-1032-21111 1101-1032-32113

Compact Cabinet

Cam-Lok® Connection Available

Integrated Power Protection Cabinets

Page 136: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Integrated Power Protection Cabinets 141

Material Heavy gauge aluminum

Finish Powder coat

Dimensions (H x W x D) in 40.0 x 24.0 x 10.0 58.0 x 24.0 x 20.0

Dimensions (H x W x D) cm 101.6 x 61.0 x 25.4 147.3 x 60.9 x 50.8

Mount Wall or H frame

Enclosure Type NEMA 3R

Relative Humidity 100% non-condensing

Operating Temperature -40°C to +75°C

Specifications

• Louver style ventilation

• Air flow filter

• 3/4” plywood back panel

• Multi-point ground bar

• Easy access front cover panel

Features

• Intrusion alarm contact

• 120 AC thermostatically controlled fan with guard

• 66 punch down block

• 12 position terminal strip

• Fluorescent lamp

• Numerous T1/E1 or Ethernet configurations available

Options

Demarcation Cabinet

Indoor/outdoor telecommunications demarcation cabinet with integrated signal line surge suppression options.

Outdoor Cabinet

Demarcation Cabinet

Model Name 40 inch 58 inch

Part Number 1101-751-T 1101-658

Integrated Power Protection Cabinets

Page 137: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

142

• Mechanically interlocked mains

• Integrated surge suppression

• 24 position load center

• Three-point latching system and pad lockable handle

• 135° wind stop

• GFCI convenience outlet

• UL 891 Listed on selected models

Features

• 100 A or 200 A generator receptacle

• Thermostatically controlled fan

• Integrated T1/E1 and/or Ethernet protection

• Integrated Cat5 punch down block

• 12 position terminal strip

• Remote status monitoring

• Numerous configurations available

Options

Combination Cabinet

120/240 Vac single phase, 100 A or 200 A, combination ACpower and telecommunications cabinet.

Outdoor Cabinet

AC Power and TelecommunicationsCombination Cabinets

Material Heavy gauge aluminum

Finish Powder coat

Dimensions (H x W x D) in 64.0 x 30.0 x 12.0

Dimensions (H x W x D) cm 162.6 x 76.2 x 30.5

Weight (max) lb, kg 150.0, 68.0

Mount Wall, concrete pad or H frame

Enclosure Type NEMA 3R

Surge Suppression Silicon diode with MOV secondary

Relative Humidity 100% non-condensing

Operating Temperature -40°C to +75°C

Specifications

Model Name PTC Cabinet

Part Number 1101-781

Integrated Power Protection Cabinets

Page 138: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Integrated Power Protection Cabinets 143

Max Continuous Operating Voltage

120/240 Vac 120/208 Vac 3 phase

Material Heavy gauge aluminum

Finish Powder coat

Dimensions (H x W x D) in 64.0 x 30.0 x 12.0

Dimensions (H x W x D) cm 162.6 x 76.2 x 30.5

Weight (max) lb, kg 150.0, 68.0

Mount Wall, concrete pad or H frame

Enclosure Type NEMA 3R

Surge Suppression Silicon diode with MOV secondary

Relative Humidity 100% non-condensing

Operating Temperature -40°C to +75°C

Specifications

• Provides main breakers for incoming power, and ATS for transfer between utility and generator sources

• 42 position load center

• LED status indication

• ASCO 300, 200 A, 2 pole ATS (automatic transfer switch)

• ASCO 300, 200 A, 3 pole ATS (automatic transfer switch)

• Remote status monitoring

Features

• Numerous configurations available

Options

Outdoor ATS Cabinet

120/240 Vac single phase, 120/208 3-phase or 200 A power protection cabinet with ATS (automatic transfer switch).

Outdoor Cabinet

Automatic Transfer Switch (ATS)

Model Name ATS 120/240 ATS 120/208 3-phase

Part Number 1101-740 1101-790-3

Integrated Power Protection Cabinets

Page 139: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

144

Material Heavy gauge aluminum

Finish Powder coat

Dimensions (H x W x D) in

63.0 x 30.0 x 12.0

Dimensions (H x W x D) cm

157.5 x 76.2 x 30.5

Weight (max) lb, kg 150.0, 68.0

Mount Wall, concrete pad or H frame

Enclosure Type NEMA 3R

Surge Suppression Silicon diode with MOV secondary

Relative Humidity 100% non-condensing

Operating Temperature -40°C to +75°C

Specifications

• Voltage sensing with automatic and manual switching between utility power and two backup power services

• GE/Zenith, 200 A ATS (automatic transfer switch)

• Remote status monitoring

Features

• Numerous AC/DC/data/signal surge protection configurations available

Options

Dual ATS Cabinet

100 A, 20 position, outdoor power protection cabinet with ATS (automatic transfer switch), intended for use in critical applications that require continuous, protected AC power to sensitive loads.

Outdoor Cabinet

Dual Automatic Transfer Switch Cabinet (ATS)

Model Name Dual ATS

Part Number 1101-892

Integrated Power Protection Cabinets

Page 140: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Integrated Power Protection Cabinets 145

Material 16 gauge steel

Finish Powder coat

Dimensions (H x W x D) in 24.0 x 24.0 x 10.0

Dimensions (H x W x D) cm 61.0 x 61.0 x 25.4

Mount Wall or pole mount

Enclosure Type NEMA 4

Relative Humidity 100% non-condensing

Operating Temperature -40°C to +75°C

Specifications

• Automated, programable, environmental control system

• AC distribution with silicon diode surge protection

• Multi-point ground bar (six position)

• Grounded metal backplane

Features

TransComm

Rugged cabinet for sensitive railway communications equipment.

Outdoor Cabinet

TransComm Rail Cabinet

Model Name TransComm

Part Number 1101-906

Integrated Power Protection Cabinets

Page 141: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Integrated Power Protection Cabinets146

Material 16 gauge steel

Finish Powder coat

Dimensions(H x W x D) in

27.0 x 20.0 x 8.0 44.0 x 20.0 x 8.0 56.0 x 20.0 x 8.0 68.0 x 20.0 x 8.0

Dimensions(H x W x D) cm

68.6 x 50.9 x 30.5

111.8 x 50.9 x 30.5

142.2 x 50.9 x 30.5

172.7 x 50.9 x 30.5

Mount Wall mount

Enclosure Type

NEMA 1

Surge Suppression

Silicon diode with MOV secondary or MOV

Relative Humidity

100% non-condensing

Operating Temperature

-40°C to +75°C

Specifications

• Single main breaker, mechanically interlocked mains, and ATS versions available

• Secure front cover panel for unit installation and load circuit additions

• Recessed circuit breaker panel

• Integrated surge protection

• Heavy duty ground bar

• UL 891 Listed on selected models

Features

• 27”, 44”, 56” or 68” configurations available

• 120/240 single phase or 120/208 three phase

• 100 A, 200 A or 400 A main breaker options

• 24, 30 or 42 position load centers

• ATS (automatic transfer switch)

Options

Interior Service Panel

Indoor AC power panel with integrated surge suppression.

Indoor Cabinet

Interior Service Panel

Model Name ISP 27 ISP 44 ISP 56 ISP 68

Page 142: Protection Technology Group USA_CATALOG_2011-2012

Integrated Power Protection Cabinets 147

This reference section includes both a catalog index and application drawings

to assist in identifying products, applications and specifications needed for network

planning and maintenance.

Additional information on the Protection Technology Group’s full

end-to-end product offering can also be found at protectiongroup.com

Page 143: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Telecommunications148

Mission critical communication providers protect their systems from maintenance costs, equipment replacement outlay, lost revenue and customer dissatisfaction by investing in transient surge protection.  This network drawing is designed to provide a basic understanding of RF, AC, DC and data line protection placement in the backhaul network. Contact the Protection Technology Group at 1.800.882.9110 or 208.772.8515 to further review your specific communication network and surge protection requirements.

Cellular Backhaul Network

Cell Site

Page 144: Protection Technology Group USA_CATALOG_2011-2012

149

Mobile Telephone Switching Office

Page 145: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

150 Rail

Railway communication systems are vital to safe and profitable rail operation, but can easily become vulnerable to lightning and power anomalies.  PolyPhaser, Transtector and LEA provide RF, AC, DC and data line surge protection solutions for onboard and wayside rail applications required for Positive Train Control deployment.  Contact our dedicated PTC sales and engineering teams at 1.800.882.9110 or 208.772.8515 for further information and network support.

Positive Train Control

Page 146: Protection Technology Group USA_CATALOG_2011-2012

151

Page 147: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

Oil and Gas152

For over four decades PolyPhaser, Transtector and LEA have worked to become industry leaders in the development, design and manufacturing of power and signal integrity solutions for the oil and gas industry. Contact our dedicated sales and engineering teams 1.800.882.9110 or 208.772.8515 to further discuss your specific requirements and review the Class I Division II products that are in place to safely support your network.

Class I Division II Approved

IO/Modem/PLC

Communication Sites

Page 148: Protection Technology Group USA_CATALOG_2011-2012

153

Refining/Processing

Pumping Station Offshore Production

Page 149: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

154 Index

DRDC, 126, 127DRI 120, 80, 81DRI 24, 80, 81, 130Dual ATS, 144Dyna Systems Series, 98, 99

EEthernet, 56-69, 141, 142

FFSP 4000 MC Series, 72, 73

GGas Tube, 14, 48, 79GbE, 56-65GbE PoE, 59, 63GR 1089, 57-63, 70, 74Grounding Accessories, 52, 53GT Series, 48-51GXJ Series, 42-47GXZ Series, 36-41

HHF Radios, 14, 24HF Series, 32-35

II2R CDS Series, 100-101I2R ICP Series, 114I2R IEP 120-50, 115I2R IEP Series, 128I2R RSA 48 3-40, 123I2R CM 230-20, 121I2R LA Series, 122I2R SA Series, 118, 119, 129I2R SA 120-50M, 117I2R SA 230-40, 120I2R SA 120-50M, 117I2R Series, 129I2R SSR, 83I2R Storm Series, 116IEC 1000-4-5, 26, 77IEC 60529, 10, 18, 42IEC 60529 IP 67, 6IEC 61000-4-5, 9, 13, 17, 21, 23, 32,

35, 39, 41, 42, 48, 51IEC 61643-1, 87-90, 108, 112-115,

118-122IEEE C62.41, 82, 90, 103, 106, 110,

114, 116IEEE C62.45, 82, 86IMAX Series, 86, 87

10/100, 56, 593DC48-20 Series, 132

AAC Cabinet, 142AC Protection, 84-123ACP 100 Series, 110, 111ACP Series, 110, 111ALPU CMM3, 70ALPU PoE Series, 68, 69ALPU Series, 64, 65APEX IV Series, 88APEX MOV, 89Application Drawings, 148-153AREMA, 82ATS Cabinet, 143, 146

BB50 Series, 14-17Belcore, 6Bridge Clip, 71Bulkhead Mount, 6, 14, 18, 24, 28

CCabinets, 138-146CB Series, 131CCTV, 74, 75CE, 68, 79, 180, 118, 126, 130CFS Series, 102Class I Division II, 79, 80, 130, 152Compact Power Cabinet, 140Component Protector, 108, 110, 112,

115, 116, 117, 120, 121, 122, 126, 128, 129, 130, 131

CPX, 56, 57

DDAS-P Series, 10-13Data Protection, 54-83DC Block, 14, 16, 18, 20, 22, 24, 26,

28, 30, 32, 34DC Edge II, 136DC Edge III, 137DC Pass, 36, 38, 40, 42, 44, 46, 48, 50DC Power Distribution, 136, 137DC Protection, 124-133DCOD Series, 133Demarcation Cabinet, 141Device Ground Adaptor, 53DIN Rail Mount, 60, 80, 83, 100, 110,

114-123, 126-130DPR, 60, 61DPS Series, 103

Indoor Cabinet, 136, 138IP 20, 111,117, 119, 121-129IS-50 Series, 24-27IS-75BB, 77ISP Cabinet, 146ITU 703, 56, 60IX Series, 66, 67

LLS Plus, 94, 95

MMCP Series, 108, 109MCP-OD, 90, 91MDS, 78MOV, 86-98, 102, 108, 109, 112,

117, 121-123, 132, 140-146

NNEBS 3V, 136NEC, 60, 68, 87, 92-96NEMA 1, 146NEMA 12, 87, 98, 99NEMA 3R, 65, 93, 101, 133, 140-144NEMA 4, 97, 145NEMA 4X, 87-90, 102NEMA LS, 92, 94NEMP Series, 28-31

OOutdoor Enclosure, 140-145

PPanel Protector, 86-102PBM Series, 71PDS Series, 79PDU, 136, 137PEEP, 52PIM, 6, 8, 10-13, 20-22PoE, 58-70PTC Cabinet, 142PV Plus Series, 92, 93

RRack Mount, 60, 106, 136, 137RF Protection, 4-51RJ-45, 57-70RMP Series, 106, 107RMP-CCTV, 76

Page 150: Protection Technology Group USA_CATALOG_2011-2012

155Index

1000-1270, 571000-1270-NF, 571100-608, 1111100-629, 110, 1111100-647, 1111100-855, 1111100-954, 1111101-115, 711101-162, 711101-299, 108, 1091101-300-1, 591101-338, 891101-372-1, 72, 731101-372-2, 731101-372-3, 731101-372-6, 731101-424, 90, 911101-446-43, 881101-460, 881101-464, 881101-511, 1311101-534, 1071101-546, 891101-560, 1071101-586, 791101-587, 791101-607, 74, 751101-608, 1111101-613, 751101-627, 1141101-629, 1141101-640, 64, 651101-645, 911101-656, 651101-678, 1271101-679, 1271101-680, 126, 1271101-681, 1271101-686, 1311101-689, 1091101-704, 761101-707, 821101-724, 1271101-732, 1091101-738, 911101-744, 821101-764, 821101-771, 911101-772-A, 621101-778, 651101-805, 701101-808, 86, 871101-808-MM, 871101-809, 871101-809-M, 86, 871101-809-MM, 871101-809-M-MM, 871101-826, 112, 1131101-828, 611101-829, 611101-830, 611101-869, 80, 81, 130

1101-870, 811101-872, 1011101-873, 68, 691101-882, 611101-897, 691101-898, 691101-900, 1361101-901, 112, 1131101-905, 611101-911, 611101-932, 691101-933, 691101-934, 691101-974, 571101-975, 571101-976, 571101-977, 56, 571101-978, 571101-979, 571101-980, 100, 1011101-981, 1011101-984, 571101-985, 571101-986, 571101-987, 571101-988, 571101-989, 571101-990, 591101-991, 591101-994, 58, 591101-995, 621101-1001, 591101-1044, 621101-1006, 1371101-1014, 1321101-1024, 1331101-1025, 1331101-1026, 1331101-1027, 1331101-1028, 631101-1029, 631101-1030, 631102-007-1A, 1031102-007-9, 106, 1071102-014-5, 1221102-014-6, 1221102-014-7, 1201102-014-8, 1211102-014-13-1, 1191102-014-26, 1191102-014-38-2, 1291102-014-42, 1191102-014-43, 118, 1191104-04-000, 1231104-09-001, 831104-11-000, 1281104-11-001, 1281104-11-002, 1281104-11-005, 1291104-15-000, 1151104-15-001, 1161104-15-002, 117

RoHS, 10, 14, 18, 24, 28, 36, 42, 58, 60, 68, 115-123, 128, 129, 136

RS232, 66RS422, 72RS485, 66, 72

SSilicon (SASD), 60-64, 71, 72-76, 88,

82, 90, 98, 100, 103, 104-108, 110-116, 126, 128, 131, 133, 140-146

Silicon | MOV, 86-88, 91, 140SL Series, 104, 105SP Plus, 96, 97SuperHy Series, 112, 113SX Series, 18-23SXRR Series, 82

TT1/E1, 55, 57, 60-62, 66, 67, 141,

142TB (Thunderbolt) Series, 63TransComm Cabinet, 145TSJ, 58, 59TSJ X6 Series, 62TSX Series, 6-9

UUL 1449 3rd Edition, 86, 88, 9;2, 96,

108, 114, 118, 140UL 497, 64UL 497A, 56UL 497B, 18, 36, 42, 56, 58, 74, 126UL 60950, 136UL 891, 140, 142, 146UL 94-5V, 91

VVHF Radios, 14

XxDSL, 60, 61, 67

Part Number1000-1206, 601000-1268, 571000-1268-NF, 571000-1269, 571000-1269-NF, 57

Page 151: Protection Technology Group USA_CATALOG_2011-2012

©2011 Transtector Systems, Inc. All rights reserved.An ISO 9001:2008 and ISO 14001:2004 certified company.

156 Index

1104-29-000, 104, 1051104-29-001, 1053PEEP, 5258R-112S, 535PB-M, 525PEEP-M, 528PB-M, 528PEEP-M, 52A70-00-5002, 102A70-00-5006, 102A70-00-5007, 102A70-00-5008, 102A70-00-5010, 102A70-00-5011, 102AL-LSXM, 19, 20, 21AL-LSXM-MA, 20, 21BGXZ+24NFNF-A, 38, 39CCK, 53CGXJ+15NFNF-A, 44, 45CGXJ+15NFNM-A, 44, 45CGXJ+24NFNF-A, 44, 45CGXJ+30NFNM-A, 42, 44, 45CGXJ+36DFDF-A, 44, 45CGXJ+36DFDM-A, 44, 45CGXJ+36NFNF-A, 44, 45CGXJ+36NFNM-A, 44, 45CGXJ+36NMNF-A, 44, 45CGXZ+15NFNF-A, 38, 39CGXZ+24NFNF-A, 38, 39CGXZ+36NFNF-A, 38, 39CGXZ+48NFNF-A, 38, 39CGXZ-15NFNF-A, 38, 39CGXZ-48NFNF-A, 38, 39CS112-25, 53CS112-50, 53CS112-100, 53CS3-25, 53CS3-50, 53CS3-100, 53CS6-25, 53CS6-50, 53CS6-100, 53CU-SPGP, 53DAS-P-DFF30, 10, 12, 13DAS-P-DFM30, 12, 13DAS-P-DMF30, 12, 13DGXE+30NMNF-A, 40, 41DGXJ-P-DFM30, 12DGXJ+15DFDF-A, 44, 45DGXJ+15DFDM-A, 44, 45DGXJ+15DMDF-A, 44, 45DGXJ+15NFNF-A, 44, 45DGXJ+24DFDF-A, 44, 45DGXJ+24DFDM-A, 44, 45DGXJ+24DFNM-A, 46, 47DGXJ+24DMDF-A, 46, 47DGXJ+24NFNF-A, 46, 47DGXJ+24NFNM-A, 46, 47DGXJ+36DFDF-A, 46, 47DGXJ+36DFDM-A, 46, 47DGXJ+36DFNM-A, 46, 47DGXJ+36DMDF-A, 46, 47

DGXJ+48DFDF-A, 46, 47DGXJ+48DFDM-A, 46, 47DGXJ+48NFNF-A, 46, 47DGXJ-48NFNF-A, 46, 47DGXZ+06NFNF-A, 36, 38, 39DGXZ+06DFDF-A, 38, 39DGXZ+06NMNF-U, 38, 39DGXZ+06TFTF-A, 38, 39DGXZ+15DFDF-A, 38, 39DGXZ+15NFNF-A, 38, 39DGXZ+15TFTF-A, 38, 39DGXZ+24NFNF-A, 38, 39DGXZ+24DFDF-A, 38, 39DGXZ+36NFNF-A, 38, 39DGXZ+48DFDF-A, 38, 39DGXZ+48NFNF-A, 40, 41DGXZ+60NFNF-A, 40, 41DGXZ-48DFDF-A, 40, 41DGXZ-48NFNF-A, 40, 41DGXZ-60NFNF-A, 40, 41DS20-300A, 99DS21-80A, 99DS21-150A, 99DS21-225A, 99DS21-300A, 99DS30-600A, 99DS30-1200A, 99DSXL, 18, 20, 21DSXL-D, 20, 21DSXL-D-MA, 20, 21DSXL-D-MA-BF, 20, 21DSXL-D-MA-P2-BF, 20, 21DSXL-D-ME, 20, 21DSXL-D-SP, 20, 21DSXL-DN-MA, 20, 21DSXL-MA, 20, 21DSXL-MA-BF, 20, 21DSXL-MA-SP, 20, 21DSXL-ME, 20, 21DSXL-P, 20, 21DT-NFF, 50, 51DT-NFM, 50, 51GSA-KIT-N, 53GT-DFF-AL, 50, 51GT-DFM-AL, 50, 51GTH-NFF-AL, 50, 51GTH-NFM-AL, 50, 51GT-NFF-AL, 48, 50, 51GT-NFM-AL, 50, 51GT-NFSF-AL, 50, 51GT-TFF-AL, 50, 51GT-TFM-AL, 50, 51IS-50NX-C1, 26, 27IS-50NX-C1-MA, 26, 27IS-50NX-C1-ME, 26, 27IS-50NX-C2, 26, 27IS-50NX-C2-MA, 26, 27IS-50NX-C2-ME, 26, 27IS-50NX-CO, 24, 26, 27IS-50NX-CO-MA, 26, 27IS-50NX-CO-ME, 26, 27IS-50UX-C1, 26, 27

IS-50UX-C1-MA, 26, 27IS-50UX-C1-ME, 26, 27IS-50UX-CO, 26, 27IS-50UX-CO-MA, 26, 27IS-50UX-CO-ME, 26, 27IS-75BB/1.5, 77IS-75BB/18, 77IS-B50HN-C1, 16, 17IS-B50HN-C2, 16, 17IS-B50HN-CO, 16, 17IS-B50HU-C1, 16, 17IS-B50HU-CO, 16, 17IS-B50LN-C1, 16, 17IS-B50LN-C2, 14, 16, 17IS-B50LN-CO, 14, 16, 17IS-B50LU-C1, 16, 17IS-B50LU-CO, 16, 17IS-NEMP-C1, 30, 31IS-NEMP-C1-MA, 30, 31IS-NEMP-C1-ME, 30, 31IS-NEMP-C2, 30, 31IS-NEMP-C2-MA, 30, 31IS-NEMP-C2-ME, 30, 31IS-NEMP-CO, 30, 31IS-NEMP-CO-MA, 28, 30, 31IS-NEMP-CO-ME, 30, 31IX-1T, 67IX-2H2DC48, 66IX-2H1DC56-IG, 67IX-2H1DC24-IG, 67IX-2H1DC48-IG, 67IX-2L, 67IX-2T, 67J-1, 53J-2, 53LS 100, 94, 95LS 200, 95LS 300, 95LSXL, 22, 23LSXL-ME, 22, 23MDS+24-F-F, 78PSXL, 22, 23PV 200, 93PV 400, 93PV 600, 93SP 100, 96, 97SP 200, 96, 97TSXDC-DFM, 6, 8, 9TSX-DFF, 8, 9TSX-DFM, 8, 9TUSX-DFF, 8, 9TUSX-DFM, 8, 9UHF50HD, 34, 35UHF50HD-MA, 34, 35UHF50HD-ME, 34, 35UHF50HN, 34, 35UHF50HN-MA, 34, 35UHF50HN-ME, 34, 35UNI-KIT-4CC, 53UNI-KIT-4CT, 53UNI-KIT-4TC, 53USXL-D, 22, 23

Page 152: Protection Technology Group USA_CATALOG_2011-2012

157Index

VHF50HD, 34, 35VHF50HD-MA, 34, 35VHF50HD-ME, 34, 35VHF50HN, 32, 34, 35VHF50HN-MA, 34, 35VHF50HN-ME, 34, 35WSXM, 20, 21

Page 153: Protection Technology Group USA_CATALOG_2011-2012

800.882.9110 | 208.772.8515 | www.ProtectionGroup.com