pse100-series ac/dc 60 to 100 w · pse100-series ac/dc 60 to 100 w input / output • 110 or 230...
TRANSCRIPT
PSE100-series AC/DC 60 to 100 WINPUT / OUTPUT • 110or230Va.c.models100W• WorldwideACinput85to264Va.c.60W• TrainbornACinputs• Singleoutputsfrom5to48Vd.c.• Lowrippleandnoise
FEATURES • Conformallycoating,tropic• Accessibleonfront: •Outputvoltageadjustment•Outputvoltagemeasurement•OutputOKstatusgreenLED
OPERATION • Operatingtemperaturerange-25to+70°C• Highefficiency• Fullyencapsulated,meetsIP20asstandard• Convectioncooled
EMC • ENIEC61000-6-3,Emission• ENIEC61000-6-2,Immunity• ENIEC61000-4-4,4kV• Bothinputandoutput
OUTPUT RATING & TYPE CODEOUTPUT INPUT
Voltage Current Power 85 - 264 V 85 - 135 V 176 - 264 V
5V 12.0A1 60W PSE60ACW5
5V 20.0A1 100W PSE100ACR5 PSE100AC5
13.2V 4.50A 60W PSE60ACW13.2
13.2V 7.60A 100W PSE100ACR13.2 PSE100AC13.2
15V 4.00A 60W PSE60ACW15
15V 6.70A 100W PSE100ACR15 PSE100AC15
24V 2.50A 60W PSE60ACW24
24V 4.20A 100W PSE100ACR24 PSE100AC24
48V 1.30A 60W PSE60ACW48
48V 2.10A 100W PSE100ACR48 PSE100AC48
How to read our product code:
Example PSE100AC24
PSE100 = Family code
AC = input voltage code AC
24 = Output voltage 24 V
1) -25 to +55 °C 100% load, 70 °C at 75% load. With extra cooler the ratings is 100% @ +70 °C , see option T3 and mechanical drawing figure 5.
INPUT VOLTAGE RATINGS
FEATURES OPTIONAL FEATURESConformal coating PSE100isconformalcoatedtowithstandnoncondensingtropicalenviromentRh95%.
Logic under voltage alarm -B1Abuiltinlogicalarmchangestoalarmstateifthecon-verteroutputvoltagedropsbelow-10%ofnominaloutput.ThealarmcircuitalsocontrolstheDCOKLED.Astandardunitisequippedwithalogicsignal.DCOKorPOWERGOODsignaluselogic1.Thedrivevoltageis6to10V,5mA=logic1,seefigure2.
Voltage adjustVoltageadjustmentandoutputvoltagemeasurementaccessiblefromfrontpanel.
Over voltage limit OVL Asecondregulationcicuittakesoverincasethemainregulationfails.Theoutputvoltageislimitedtoapproximately+15%overnominaloutputvoltage.
Overvoltage protection OVP-ATheoutputvoltageislimitedto15%overnominal outputvoltage.Athyristorshort-circuitstheoutput.
Built in series diode -C (Derating 20 %)Aseriesdiodeontheoutput,whichismountedinsidethecase.Usethisoptionwhenoutputisconnectedinparallelwithotherpowersuppliestoachiveredundancy.Theout-putpowermightbederated.It´smodeldependent,pleasecontactfactory.
Built in series diode with resistor - CRTheCRoptionautomaticallybalancetheloadbetween2ormoreparalleledPSEunits.
Remote sense -SThevoltagesensingcanbeputattheloadtocompensateforvoltagedrop.Isastandardfeatureon5Voutput.Thesensecancompensateforvoltagedropsupto5%ofthenominalvoltage.
2.5 kVa.c. isolation output/case, option E2
Under voltage alarm relay -B2ThelogicalarmoutputisreplacedwitharelaywithselectablealarmlogicNOorNC.Alarm=Noinputorlowoutput<-10%ofnominaloutput,seefigure3. Therelayisrated30V,0.5A(a.c.&d.c.).
Extra cooler, option T3ThePSEcasecanaccommodate2extracoolers.Someoptionse.gseriesdiodewillrequireanextracoolertoavoidderating20%ortheEN50155/IEC60571T3temper-atureclassificationrequiring+85°Cduring10min. Eachcooleris10mm,whichincreasethesizeandweightaccordingly.
Figure 1. Pin-out DIN 41612, H15
Figure 3. Alarm relay output Option B2
Figure 2. 5 V logic alarm signal Option B1
INPUT
Nominal inputs Input range Code
100,110,220,230,240Va.c. 85-264V ACW
100,110Va.c. 85-135V ACR
220,230,240Va.c. 176-264V AC
GENERAL DATA / INPUT DATA OUTPUT DATA
MECHANICAL DRAWING
LABEL VALUE
Sourceregulation 0.2%
Loadregulation(0to100%load) 0.2%
Transientrecoverytimefor
10to100%voltagedeviation
<2ms
3%
Outputripple(100kHz)1 Typ10mVp-p
Inputripple(100Hz)Uin230Va.c. <10mVrms,50mVp-p
Inputripple(100Hz)Uin110Va.c. <20mVrms,100mVp-p
Emission/Immunity Seepage4
Temperaturecoefficient 0.02%/°C
Minoutputadjustmentrange
adjustablewitha15turn
potentiometer
90-110%
Currentlimit,rectangular 105%
Remotesense OptionS
Softstart Yes
Start-uptime <1s
Reversevoltageprotectiononoutput Paralleldiode
Hold-uptime,contactfactory
PSE60ACW(230Va.c.)
PSE60ACW(110Va.c.)
PSE100AC(230Va.c.)
PSE100ACR(110Va.c.)
20ms
3ms
10ms
3ms
Efficiency2PSE60ACW
PSE100AC(230Va.c.)
PSE100ACR(110Va.c.)
80-85%
80-88%
82-91%
Operatingtemperaturerange
at100%load,conductioncooling
withoutputs>10V
-25to+70°C
Operatingtemperaturerange
at100%load,conductioncooling
withoutputs<10V -25to+55°C
Storagetemperaturerange -40to+85°C
Optional -40°C
LABEL VALUE
Designtopology Push-Pull
Switchingfrequency 100kHz
Emission/Immunity Seepage4
ACfrequencyrange 48-420Hz
Inrushcurrentlimit WithNTC
Powerconsumptionatnoload 3to5W
VibrationEN/IEC61373 BodymountedClassB
Isolation Seetablepage4
FireProtectionEN45545-2HL3
level4.3.2rule1andfigure1
“Nonlistedproduct”
<100g
Dimension(DxHxW)mm 167x106x37|47|57
Weight 0.8-1.3kg
1. The output ripple might increase to 0.5% RMS of Vout, when EN IEC 61000-4-3, 10 V/m test is applied. 2. Lowest efficiency measured within the whole input voltage range at 100% load.
Mechanical Options FrontpanelforEuroformat,optionL,seefigure4-68TEforPSE60andPSE10010TEfor5Voutputwithextracooler,optionT3Wallmountingpanels,optionN,seefigure7and8Includingconnectorholder.H15CageClamptypefemale-H15-CC(ThecableratingisAWG16or<1.5mm2.Thatmakesitnotusablefor5Voutputs)
H15FastOn6.3mmfemale-H15-TDINrailTS35clips-Q,seefigure8
42 mm
200 mm
49 m
m49
mm
106
mm
190 mm
15 mm13 mm
210 mm4.2 mm
(52mm withextra cooler)
Figure 6. 3HE 19” sub rack mounting.
Figure 4. Dimensions.
Weight: 0.8 kg.
Figure 8. Wall mounting Option -N
Figure 7. Dimensions with option N, wall mounting Weight: 0.95 kg and with extra cooler T3 | 2xT3: 1.1 | 1.3 kg.
PSE wall mounted.Using PSE wall mounting kit, option N, with connector holder, female H15 connector with cage clamp or tab connectors (Optional).
PSE DIN-rail mounted.Using PSE wall mounting kit, option N with addition of 2x DIN-rail clips, (Optional)
PSE mounted in a 19” Sub-rack. Standard unit.
PSE mounted in a 19” Sub-rack with L panel 8, 10 or 12 TE (Optional)
Figure 5. Optional extra cooler version. Weight: 1xT3 1.1 | 2xT3 1.3 kg
EMC
CE MARKPSE100meetstherequirementsdefinedbyCEmarkas apparatus.
PSE100meetsrequirementsofEMCdirectiveandlow voltagedirective(LVD)andRoHSIIdirective.
ThePSE100familyisinrespecttoEMC,astandaloneunitthatcanalsobeinstalledinanyotherenvironmentbyaprofessionalinstaller.
Pleasenotethatproductstandardscandemanddifferentlevelsorotherbasicstandardtests.Wetestaccordingtolevelsbelow.Forhigherlevelsorothertests,contact factory
SAFETY STANDARD EN/IEC 60950 ISOLATIONTESTABLELEVELS TESTVOLTAGE
Input/Output 2.5kVa.c./4kVd.c.
Input/Case 2.5kVa.c./4kVd.c.
Output/Casealloutputs 2kVd.c.
ISOLATIONTESTABLELEVELS SAFETYISOLATION
TransformerisolationIn/Out 4kVa.c./8mm
HEADOFFICEPolyampAB Box925 SE-19129Sollentuna Sweden Phone: +46859469300 Telefax:+46859469305
SALESOFFICE PolyampAB Box229 SE-59725Åtvidaberg Sweden Phone: +4612085410 Telefax:+4612085405
Email:[email protected]
SALESOFFICESwitchCraftS.A RuelbelAir63 CH-2300LaChaux-de-fondsSwitzerland Phone: +41329678800Telefax:+41329678809
EMCSTANDARDS EMCPERFORMANCE REMARKS
Emission standards EN IEC 61000-6-3 Commercial and light-industrial environments
Input Output
EN55016CISPR16(0.15-30MHz) OK OK opt.EN55022levelB
EN55016CISPR16(30-1000MHz) OK Enclosuretest
Immunity standards EN IEC 61000-6-2 Industrial environments
ENIEC61000-4-2 8kV/15kV Contact/air,Enclosuretest
ENIEC61000-4-3 10V/mAM-Modulated2 Outputripplecanincreaseto
0.5%ofVoutEnclosuretest
ENIEC61000-4-4 ±4kV ±4kV
ENIEC61000-4-5 ±1kV/±2kV1 ±0.5kV/±1kV Line-line2Ω/Line-case12Ω
EN50121-3-2,IEC62236-3-2 ±1kV/±2kV ±1kV/±2kV Line-line42Ω/Line-case42Ω
ENIEC61000-4-6 10VRMS 10VRMS AM-Modulated
ENIEC61000-4-8 Notsensitive Enclosuretest
ENIEC61000-4-10 Notsensitive Enclosuretest
ENIEC61000-4-11 Yes NA
1. Higher level 2 kV / 4 kV with external filters, contact factory.
2. Level increased to 20 V/m on T-inputs.
We use the EMC product standard ”Low voltage power supplies DC output” EN 61204-3 as base for measurement principles. The Immunity EMC levels are elevated in order to comply to EN 50121-3-2 (IEC 62236-3-2) Railway application: Rolling stock – Apparatus, and EN 50121-4 (IEC 62236-4) Railway application: Signaling and telecommunication apparatus. Also to meet relevant parts of IEC 61000-6-5 Generic Standards – Immunity for power stations and substation environments.
Polyamp AB 4287-13 PSE100 AC-DC Converters
Installation Class I, optional Class II