With Power assist the MultiPlus can add3KW to the output load when needed.Together with the adjustable 50A input thisall adds up to the max sum of input andoutput current of 50+25=75A. An Earthleakage device with breaker or acombination MCB/RCD must be installedon the output. Cable size must be adjustedaccordingly.
Recommended AC Out-1 cable/breaker size MultiPlusAC Out-2 only is available when power ispresent on AC IN. During battery operationit will be disconnected.AC Out-2 supports up to 25A.An Earth leakage device with breaker or acombination MCB/RCD must be installedon the output. Cable size must be adjustedaccordingly.
Recommended AC Out-2 cable/breaker size MultiPlus120 VOLT AC IS EXTREMELYHAZARDOUS !!!DO NOT TOUCH ANY LIVE WIREDPARTS OF THE INSTALLATION !!!WHEN IN DOUBT, ALWAYS CONSULTYOUR VICTRON DEALER !!!
WARNING
Drawing BJE-276A
RESET
60 A
MP
ER
ETH
ER
MA
L C
IRC
UIT
BR
EA
KE
R
2850
60F
L O A D
BAT
BUSBARPOSITIVE
SUPPLIED UTP CABLE
BMS 2A
Spare xxA
Battery Pre Main Fuses
BMV 100mA
Li-DISTRIBUTION
VE.Bus MAINS DETECTOR MultiPlusREMOTE PANEL
12.8V-200AhSmart LiFePO4
POS. NEG.
CYRIX Li CHARGE 230
CYRIX LiCHARGE
230
Maximum 5mA
BMS ON/OFF
ANL
350A
The VE.Bus BMS is enlargedvisible in this drawing.The BMS GND is not connectedto prevent ground loops.Ground comes through theVE.Bus UTP cable.
xxxAMEGA
xxxAMEGA
xxxAMEGA
xxxAMEGA
xxxAMEGA
MAIN DCDISTRIBUTION
BUSBARPOSITIVE
2 x Lithium
MAIN SWITCH-2
PV BREAKERS/ISOLATORS
VE
.Bus
COLOR CONTROL GX
VE
-direct-1
VE
-direct-2
SMART BATTERY PROTECT 220
SOLAR ARRAY
VE.Bus BMS
FROM MPPT
FROM MultiPlus
THE BMV SHUNT CAN BE UPGRADEDFROM STANDARD 500A TO 1000A.THE BMV SHUNT IS MOUNTEDDIRECT ON BOTH BUSBARS.KEEP NEGATIVE BATTERY CABLES
ALL AS SHORT AS POSSIBLE ANDALL AT THE SAME LENGTH !
KEEP POSITIVE BATTERY CABLESALL AS SHORT AS POSSIBLE ANDALL AT THE SAME LENGTH !
M8 CIRCULARCONNECTOR
M8 CIRCULARCONNECTORS
The SmartBatteryProtect must beprogrammed for Li-Ion mode-C and 12 Volteither through programming on the deviceitself or with a Bluetooth enabledsmartphone or tablet.Connect the load disconnect output of theVE.Bus BMS to Remote H terminal.
CENTRALNEGATIVE BUSBAR
INVERTER/CHARGERMultiPlus / 3KW/12V/120V-60Hz AC
BMV-712 SMART
SMART MPPT
SmartSolar charge controllerMPPT 100 | 50
12/24V 50A
Bul
k
Abs
orbt
ion
Floa
t
BATTERY PV
+ - - +
victron energyBLUE POWER
Battery100V 50APV
IP43! i
max
VE
-direct
FUSE
CCGX 1A
5x20mmCCGX POWER +
VRMWORLDE
THE
RN
ET
V+GND
BMV POWER +
ISOLATION TRANSFORMEROR GALVANIC ISOLATORSHOULD BE INSERTEDHERE IF NEEDED.INCLUDING NECESSARYBREAKERS.
SHORE POWERCONNECTION
Drawing BJE-276A
125/250VEasy Lock
50A
Shore Generatorpower power
MultiPlusAC out-2
MultiPlusAC out-1
from MultiPlusAC DISTRIBUTION
120V/60Hz ACGENERATOR 4KW
120V/60Hz AC
When operating in inverter mode, the Neutral output ofa inverter/charger must be connected to ground toguarantee proper functioning of a GFCI or RCD device.In case of a split phase supply the Neutral also mustbe grounded.The primary Case ground connection from a invertercharger like a Multi or a Quattro, must be connected tothe Central Negative Busbar of the DC system. Size ofthis cable must be identical to connected DC negative.
IMPORTANT INFORMATION ! IMPORTANT INFORMATION ! IMPORTANT INFORMATION ! IMPORTANT INFORMATION ! IMPORTANT INFORMATION !
VE.Bus BMS mainsdetector inside MultiPlus
M8 CIRCULARCONNECTOR
BTV CABLEBTV CABLE
M8 CIRCULARCONNECTOR
30
50
31
ALTERNATOR
12V Charger
B+D+B-
12V-150AALTERNATOR
INTERNALALTERNATOR
FUSE
STARTERMOTOR
BMV-B2 / 100mA FUSE
175AAMI
ORION-Tr SMART-1
In both Orion-Tr Smart Ignition remote on/offand engine detection override are active
WIRE LINKBETWEEN L & H
HL
FROM STARTER+(30)
MAIN SWITCH-3
IGNITION
30 15
Charge light
xx AMP.FUSE
FROM ALTERNATOR D+
OFF
ONm
10A FUSE
Blue SmartCharger 12V-5ASTARTER-MOTOR
Orion-Tr Smart
Non-isolated DC/DC charger12 I 12 - 30
on/off
victron energyBLUE POWER
Input Output
IP43iI 8-17V
PowerI 10-15VI 360W (30A)
IN OUT
+ - +
GND
Orion-Tr Smart
Non-isolated DC/DC charger12 I 12 - 30
on/off
victron energyBLUE POWER
Input Output
IP43iI 8-17V
PowerI 10-15VI 360W (30A)
IN OUT
+ - +
GND
ORION-Tr SMART-2
RESET
60 AMPERETHERMAL CIRCUIT BREAKER
285060F
LOAD
BAT
RESET
60 AMPERETHERMAL CIRCUIT BREAKER
285060F
LOAD
BAT
SELECTSETUP
BATTERY MONITORBMV-712 SMART
V
victron energyBLUE POWER
MAIN
color
victron energyBLUE POWER
control
victron energy
InvertingAC Input AC Loads
0W 45W
75%- +
219W12.8V 17.1A -75W
DC Power
victron energyPV-Charger
345W
MAIN SWITCH-1
HL
ORION-1 L/H-CONTACT
ENGINE SYSTEM
WIRE LINKBETWEEN L & H
ORION-2 L/H-CONTACT
Starter BatteryIP-65 | waterproof
S
victron energyB L U E P O W E R
mode
li-ion
recondition
high [14.7V]
normal [14.4V]
blue smartcharger
12V 5AStarter Battery +
MAIN FUSES Orion Inputsas close to starter battery
as possible
Conn-G Batt+
Conn-G Batt+
Conn-F Batt-
Conn-F Batt-
Conn-L Case ground
Shore power Generator power
BP220 GND-CCGX-
CYRIX LI-
MultiPlus Case Ground
MultiPlus Batt-
MultiPlus Batt-
Engine-
MPPT-
Load 1 - Load 2 -
Load 3 -
Load 4 -
Load 5 -
Load 1 +
Load 2 +
Load 3 +
Load 4 +
Load 5 +
MPPT +
ORION 1 +
ORION 2 +
BUSBARPOSITIVE
POSITIVEBUSBAR
OFF
ON
BTV
CA
BLE
BTV
CA
BLE
CCGX POWER +
VE.Bus MAINS DETECTOR MultiPlus
ALARM LED +
BMS POWER+BMS LOAD DISCONNECTBMS CHARGE DISCONNECT
ALARM LED -
+B1+B2
MultiPlus Batt +
MultiPlus Batt +
400AMEGA
OFF
ON
Shore Gen0
AC BREAKERSTOWARDSMultiPlus
MAIN INCOMING
Recommended DC cable/fuse size MultiPlus Recommended AC INcable/breaker size MultiPlusAC IN must be protected by a circuitbreaker rated at 50A max or less. Thisdepends heavily on the size of theconnected power source.The input currentmust be adjusted to fit the size of theconnected power source.The breaker and cable size for AC INshould be adjusted accordingly.
0 OFF
:hager
0 OFF
:hager
0 OFF
:hager
0 OFF
:hager
0 OFF
name
0 OFF
MCB
0 OFF
name
0 OFF
MCB
AC Out-1 & AC Out-2
0 OFF
name
0 OFF
MCB
0 OFF
name
0 OFF
MCB
ON
1 2
V-SENSET-SENSE AUX1 AUX2RELAY
GNDCHARGETRICKLE K1 K2
+ - + - + - + - + -NC NOS1 S2 + COM NC NO COM
AC IN-1
GROU
ND
BATTERY__
BATTERY++
BATTERY
BATTERY
LIN
E
NEUT
RAL
AC OUT-2
LIN
E
NEUT
RAL
AC OUT-1
GROU
ND
LIN
E
NEUT
RAL
GROU
ND
LIN
E
NEUT
RAL
VE.Bus-1 VE.Bus-2
L N G L N G L N
NO
T IN
US
E
MultiPlus12 |3000 |120
charger inverterinverter onoverloadlow batterytemperature
mains onbulkabsorptionfloat
I on
charger onlyO off
.battery charger
.powerassist.transfer switch.three phase
.sinewave inverter
.parallel connectable
AC transfer capacity: 50A | Inverter 120V
VOLT
VA AM
P
www.victronenergy.com
CE
victron energyBLUE POWER
Battery
AC in 1 AC out 1
AC out 2
vic
tro
n e
ne
rgy
BL
UE
PO
WE
R
VE.B
us B
MS
Mai
ns d
etec
tor
IN IN OUT-1 OUT-1 OUT-2
MultiPlus AC OUT-1
MultiPlus AC OUT-2
MultiPlus AC IN-1
VE.Bus to CCGX
VE.Bus mains detector to BMS
Starter Battery +
BMV-712 Smart120V Switched load-1120V Switched load-2120V No Break load-1120V No Break load-2
Blue Smart charger
0-5 m cable length: 4 x 50SQmm, 5-10 m cablelength: 4 x 70SQmm. When used in closedconduits, cable size should double. Cable lengthstands for the distance between the battery and theMultiPlus connections !!! Recommendations arewithout other loads in the system and these alsoshould be taken into account for proper mainbattery, main fuse & main switch cables !!!Fuse size should be 400A.
FUSES5x20mm