readme panel

6
 SIMATIC HMI WinCC flexible 2007 Installing the Master License Key  __ __ Installing the Master License Key MLK) on a CE HMI device 1  SIMATIC HMI WinCC flexible Installing the Master License Key Readme 07/2008 A5E02311701-01

Upload: fernando-figueredo

Post on 05-Oct-2015

225 views

Category:

Documents


0 download

DESCRIPTION

siemes

TRANSCRIPT

  • SIMATIC HMI WinCC flexible 2007 Installing the Master License Key ______________Installing the Master License Key (MLK) on a CE HMI device

    1

    SIMATIC HMI

    WinCC flexibleInstalling the Master License Key

    Readme

    07/2008 A5E02311701-01

  • Legal information Legal information Warning notice system

    This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger.

    DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

    WARNING indicates that death or severe personal injury may result if proper precautions are not taken.

    CAUTION with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken.

    CAUTION without a safety alert symbol, indicates that property damage can result if proper precautions are not taken.

    NOTICE indicates that an unintended result or situation can occur if the corresponding information is not taken into account.

    If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage.

    Qualified Personnel The device/system may only be set up and used in conjunction with this documentation. Commissioning and operation of a device/system may only be performed by qualified personnel. Within the context of the safety notes in this documentation qualified persons are defined as persons who are authorized to commission, ground and label devices, systems and circuits in accordance with established safety practices and standards.

    Proper use of Siemens products Note the following:

    WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be adhered to. The information in the relevant documentation must be observed.

    Trademarks All names identified by are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.

    Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions.

    Siemens AG Industry Sector Postfach 48 48 90026 NRNBERG GERMANY

    A5E02311701-01 07/2008

    Copyright Siemens AG 2008. Technical data subject to change

  • Installing the Master License Key Readme, 07/2008. A5E02311701-01 3

    Table of contents

    1 Installing the Master License Key (MLK) on a CE HMI device ................................................................... 5

  • Table of contents

    Installing the Master License Key 4 Readme, 07/2008, A5E02311701-01

  • Installing the Master License Key Readme, 07/2008, A5E02311701-01 5

    Installing the Master License Key (MLK) on a CE HMI device 1Validity

    The Master License Key activates a software product for which a UCL or EPL contract exists. The described function is only possible on Windows CE HMI devices that have an operating system version WinCC flexible 2007 or higher.

    MLK- Master License Key Some options for HMI devices with Windows CE are provided with license protection. As a rule License Keys are therefore installed on the HMI device that are queried by the software of the HMI device. The license query installed in the software is deactivated by means of a MLK (Master License Key). Instead, a customer-specific identifier is stored. When Runtime is started, the following is displayed in a splash screen: The customer-specific identifier The list of the installed options or MLKs The MLK is transferred using ProSave or WinCC flexible.

    Conditions The CD with the required MLK is inserted in the PC. ProSave is installed on the PC. Alternatively, use WinCC flexible to transfer the MLK.

  • Installing the Master License Key (MLK) on a CE HMI device

    Installing the Master License Key 6 Readme, 07/2008, A5E02311701-01

    Procedure for installing MLK 1. Connect the HMI device to the PC in accordance with the selected transfer type. 2. Check the parameters for the desired transfer type on the HMI device and switch to

    "Transfer" mode. 3. From within WinCC flexible:

    Select the "Project > Transfer > Transfer settings" command in the menu. The transfer settings dialog box is displayed.

    Select the HMI device type and enter the transfer parameters. Select the "Project > Transfer > Options" command in the menu.

    4. ProSave standalone: Start ProSave and select the "General" tab. Select the HMI device type. Enter the connection and connection parameters. Go to the "Options" tab.

    5. Under "Select:" navigate to the CD drive in which the CD with the MLK is inserted. The MLK of the inserted CD is displayed in the left-hand window on the "Options" tab.

    6. Select the MLK in the left-hand window. 7. In order to transfer the MLK, click ">>".

    The selected MLK is transferred to the HMI device and then displayed in the right-hand window.

    Result You have transferred the MLK to the HMI device.