replacing the touch pca - promethean world · 2020. 7. 3. · fitting of the replacement touch pca...

3
Replacing the Touch PCA: PCA-5668000A

Upload: others

Post on 28-Jan-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

  • Replacing the Touch PCA: PCA-5668000A

  • � Touch PCA Replacement Guide ©���� Promethean Ltd.

    � ENSURE THAT THE ACTIVBOARD IS DISCONNECTED FROM THE MAINS POWER

    Remove the USB and PSU connections from the bottom right hand side of the ActivBoard as shown opposite

    : -���

    A

    Promethean Recommendation: e following procedures are to be carried out by a competent person on an ActivBoard that has been removed from the system

    Tools Needed: No � Pozi Screwdriver

    ATTENTION

    Observe precautions for handling ELECTROSTATIC DISCHARGE SENSITIVE DEVICES.

    � Remove the screws from the rear cover located on the top right hand side of the ActivBoard as shown opposite

    N.B. One of the screws may be shorter in length when compared to the other screws and this MUST be refi tted into the same original location

    Hint: Place the screws with the cover so that you know where they came from

  • � Remove the cover to reveal the Touch and Pen Electronics as shown opposite

    Hint: Take a photo or label the connections so that you know where everything goes!

    � Removing the Touch PCA consists of disconnecting the DC Power cable, removing x screws (fi g�), disconnecting the small ribbon cable (fi g� – Prior to doing this, double check that the Activboard is not connected to the mains or via USB) and � x large ribbon cables (fi g)

    N.B. One of the screws may be silver coloured and must be refi tted into the same original location

    Take care whilst disconnecting the ribbon cables, it is recommended to place your thumb on top of the black plastic connector and your index fi nger behind the ribbon cable – do not disconnect by just pulling the ribbon cable.

    N.B. e grey plastic mount needs to be retained for fi tting the replacement Touch PCA

    Fitting of the replacement Touch PCA is simply the reversal of the steps above

    ATTENTION

    When reassembled it is important that all connectors are pushed fully home

    If replacing either the Pen or Touch PCA, the pen and touch will need recalibrating

    See separate Touch Calibration Document

    ©2011 Promethean Ltd. All Rights Reserved. Products are subject to availability by country. Product Specifi cations are subject to change without notice. Touch PCA/11 v1.0

    For more information visit Promethean Knowledgebase: www.PrometheanKB.com