    Getting Results Guide

  • 7/22/2019 RSEMU Getting Results

    2/60

    ii

    Contacting

    Rockwell Software

    Technical Support Telephone1-440-646-5800

    Technical Support Fax1-440-646-5801

    World Wide Webwww.software.rockwell.com

    Copyright Notice 2002-2004 Rockwell Software Inc. All rights reserved

    Printed in the United States of America

    This manual and any accompanying Rockwell Software products are copyrighted by Rockwell

    Software Inc. Any reproduction and/or distribution without prior written consent from Rockwell

    Software Inc. is strictly prohibited. Please refer to the license agreement for details.

    Trademark Notices The Rockwell Software logo, RSLogix Emulate 5000, RSLogix 5000, Logix5000, RSTestStand,

    RSView32, RSView ME, RSView SE, and RSLinx are trademarks of Rockwell Automation Inc.

    Microsoft, Windows, and Windows NT are trademarks of Microsoft Corporation.

    Pentium is a trademark of Intel Corporation.

    All other trademarks are the property of their respective holders and are hereby acknowledged.

    Warranty This Rockwell Software product is warranted in accord with the product license. The product's

    performance will be affected by system configuration, the application being performed, operator

    control and other related factors.

    The product's implementation may vary among users.

    This manual is as up-to-date as possible at the time of printing; however, the accompanying

    software may have changed since that time. Rockwell Software reserves the right to change any

    information contained in this manual or the software at anytime without prior notice.

    The instructions in this manual do not claim to cover all the details or variations in the equipment,

    procedure, or process described, nor to provide directions for meeting every possible contingency

    during installation, operation, or maintenance.

  • 7/22/2019 RSEMU Getting Results

    3/60

    CONTEN

    Contents

    1 Installing RSLogix Emulate 5000

    Process of Installing RSLogix Emulate 5000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Hardware and Software Requirements for RSLogix Emulate 5000 . . . . . . . . . . . . . . .

    Installing RSLogix Emulate 5000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Installing RSTestStand Lite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Getting Assistance with RSLogix Emulate 5000. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2 An Overview of RSLogix Emulate 5000

    Components of RSLogix Emulate 5000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    What RSLogix Emulate 5000 Can and Cannot do. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    About Floating Point Calculations and the Emulator . . . . . . . . . . . . . . . . . . . . . . . . .

    A Brief Outline of Using RSLogix Emulate 5000 . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    3 Using the Chassis Monitor 1

    Starting the Chassis Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Navigating in the Chassis Monitor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Creating an Emulation Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Configuring the Emulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Creating Simulated I/O . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Configuring the Chassis Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    4 Connecting the Emulator to

    RSLogix 5000 2

    Creating a Communications Driver for the Emulator . . . . . . . . . . . . . . . . . . . . . . . . .

    Setting a Logic Project to Use the Emulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Configuring Communications in the Logic Project . . . . . . . . . . . . . . . . . . . . . . . . . . .

    5 Connecting the Emulator to RSView 2

    Creating an OPC Topic for the Emulator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Creating a Communications Node in an RSView Project . . . . . . . . . . . . . . . . . . . . . .

    Adding Tags from Your Logic Project to Your RSView Project . . . . . . . . . . . . . . .

    6 Simulating I/O 3

    Configure Simulated I/O in the Logic Project . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • 7/22/2019 RSEMU Getting Results

    4/60

    GETTINGRESULTSWITHRSLOGIXEMULATE5000

    iv

    Configuring Produced and Consumed Tags . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Using RSView or RSTestStand to Simulate I/O . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    7 Programming Breakpoints and Tracepoints 3Programming Breakpoints . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Programming Tracepoints . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    String Formats for Tracepoint and Breakpoint Instructions . . . . . . . . . . . . . . . . . . . .

    Using Trace Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    8 Software Activation 4

    About the Activation Disk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Two Methods for Activating RSLogix Emulate 5000 . . . . . . . . . . . . . . . . . . . . . . . . .

    Activating RSLogix Emulate 5000 after Installation. . . . . . . . . . . . . . . . . . . . . . . . . .

    Protecting Your Activation Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Reactivating a Damaged Activation Key. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Troubleshooting Activation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Index 5

    http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/
  • 7/22/2019 RSEMU Getting Results

    5/60

    1 Installing RSLogix Emulate 5000

    Process of Installing RSLogix Emulate 5000

    The process of installing RSLogix Emulate 5000 is as follows:

    1. Install prerequisite software for RSLogix Emulate 5000. See Software Requirement

    on page 2for more information.

    2. Install RSLogix Emulate 5000. SeeInstalling RSLogix Emulate 5000on page 2for

    more information.

    Hardware and Software Requirements for RSLogix Emulate 5000

    Hardware Requirements

    The computer on which you are installing RSLogix Emulate 5000 must meet the

    following minimum requirements.

    You cannot install RSLogix Emulate 5000 on a computer that has a SoftLogix5800 controller

    installed.

    You must use a version of RSLogix Emulate 5000 that matches the version of RSLogix 5000

    used to develop the logic project you want to emulate. For example, if you want to emulate a log

    project developed with version 12 of RSLogix 5000, you must use version 12 of RSLogix Emula

    5000.

    For this component: Use:

    Personal computer Any with an IntelPentium Pro, Pentium II, Pentium III, or Pentium 4

    CPU running at 300 MHz or higher

    RAM 128 MB or more

    Monitor and video card Any capable of displaying a resolution of 800 x 600 pixels or higher

    Hard drive 50 MB of available hard drive space

  • 7/22/2019 RSEMU Getting Results

    6/60

    GETTINGRESULTSWITHRSLOGIXEMULATE5000

    2

    Software Requirements

    The following software must be installed before installing RSLogix Emulate 5000.

    Installing RSLogix Emulate 5000

    To install RSLogix Emulate 5000:

    1. Log onto the computer on which you want to install the emulator as an administrato

    (or a user with administrative privileges).

    2. Insert the RSLogix Emulate 5000 CD-ROM into the computers CD-ROM drive. Th

    setup program should start automatically. If it does not, open the CD-ROM drive wi

    Windows Explorer and run the AUTORUN.EXE program on that drive.

    3. The Setup program displays a menu of choices. Click Install RSLogix Emulate

    5000.

    4. The Setup program displays a welcome screen. Click Next.

    For this software

    component: Install: Notes:

    Operating system Microsoft Windows XP

    Professional Edition or Windows

    XP Home editions (either one with

    Service Pack 1 or higher)

    - or -

    MicrosoftWindows 2000 (with

    Service Pack 2 or higher)

    - or -

    MicrosoftWindows NT 4.0

    (with Service Pack 6a or higher)

    The emulator will not run on other

    versions of Windows.

    Logix5000 programming

    software

    RSLogix 5000, version 12.0 or

    higher

    Required to program the emulator a

    observe its operation.

    Communication software RSLinx, version 2.41 or higher Required for communicating with t

    emulator.

    You cannot install RSLogix Emulate 5000 on a computer that has a SoftLogix5800 controller

    installed.If you are reinstalling RSLogix Emulate 5000, you must uninstall it before proceeding with the

    installation.

    Use the Windows Add/Remove Programs application (located in the Windows Control Panel)

    remove the emulator.

    http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/
  • 7/22/2019 RSEMU Getting Results

    7/60

    1 INSTALLINGRSLOGIXEMULATE50

    5. The Setup program displays the License Agreement for the software. Read the

    agreement carefully. If you choose to adhere to the terms of the agreement, click Yes

    If you do not accept the terms of the license agreement, the Setup program stops.

    6. The Setup program displays the Customer Information screen. In this screen, enteryour name, the name of the company you work for, and your ten-digit software seria

    number (provided with the software) in the fields provided. Click Next.

    7. The Setup program asks you to choose a location for installing the software. By

    default, the software is installed in the C:\Program Files\Rockwell Software\RSLog

    Emulate 5000 folder. If you want to change the location where the software will be

    installed, click Browseand select a new location for the software. After choosing th

    folder, click Next.

    8. The Setup program asks you to choose the folder in the Start menu that will contain

    the icons for the emulator. You can choose to use the default folder (Rockwell

    Software), type a different folder name in the Program Foldersfield, or choose afolder that already exists from the Existing Folderslist.

    9. The Setup program installs the software. When the software is installed, the Setup

    program asks if you want an icon for the Chassis Monitor added to your Windows

    desktop. The icon will give you a shortcut to starting the emulators Chassis Monito

    application. If you want an icon for the Chassis Monitor added to your desktop, clic

    Yes. If not, click No. (If you do not place the Chassis Monitor icon on your deskto

    you will need to access the Chassis Monitor through the Start menu.)

    10. The RSLogix Emulate 5000 setup program displays a screen saying that its

    installation is complete. If you want to display the release notes for the software,

    check the I would like to view the README filecheck box. The README file

    contains information concerning the software that has changed since the publication

    of this book. If you have not already installed the activation for the software, check

    the I would like to Move Activation to my Hard Diskcheck box.

    11. Click Finishto end the RSLogix Emulate 5000 setup program. The setup program

    ends. If you chose to view the README file in step 10, the file opens.

    If you chose to move the activation file in step 10,the EVMove program starts. Thi

    program will move the activation file from the RSLogix Emulate 5000 Master Disk

    (provided with the software) to your hard drive.

    a. Insert your RSLogix Emulate 5000 master disk into your computers floppy disk

    drive.

    The activation file is required for the proper operation of RSLogix Emulate 5000. See Chapter

    for more informationabout software activation.

  • 7/22/2019 RSEMU Getting Results

    8/60

    GETTINGRESULTSWITHRSLOGIXEMULATE5000

    4

    b. On the EvMove window, set the From Drivebox to the letter for your computer

    floppy disk drive (usually A:). Set the To Drivebox to the letter for your

    computers hard drive (usually C: or D:).

    c. Click OK. The setup program displays the License Move Utility. This shows thactivation on the master disk and the activations that are already installed on you

    hard disk.

    d. Click the activation you want to move from the master disk (WED32.EXE), the

    click Move.

    e. After EvMove moves the activation, it displays the Move Summary window. Th

    window informs you about the activations that were moved. Click OK.

    2. Click Move.

    1. Click the activation

    you want to move

    (WED32.EXE)

    http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/
  • 7/22/2019 RSEMU Getting Results

    9/60

    1 INSTALLINGRSLOGIXEMULATE50

    Installing RSTestStand Lite

    About RSTestStand Lite

    RSTestStand Lite gives you a better user interface to your debugging process helping

    you shorten commissioning time by having better tested logic for your Logix5000

    controller.

    The functions in RSTestStand Lite are a subset of the features in the full RSTestStand an

    Control Planner/ Simulator products. The Lite version acts like a hardware test stand or

    button panel. Op Console devices replace common hardware elements (such as push

    buttons and pilot lights) that are traditionally used to test programs.

    The full RSTestStand product replaces the field inputs and outputs to your PLC with a

    simulation of your process. Unlike traditional hardware-based test systems, RSTestStan

    can be easily and quickly configured to represent a wide variety of processes discrete

    through continuous. Once configured, the system can respond automatically to differencontrol signals. In addition, the product provides an extensive user interface that lets yo

    dynamically interact with your control program through the process checking for erro

    and determining system response to out-of-range conditions.

    You can get information about the full RSTestStand product from the Rockwell Softwar

    Web site (http://www.software.rockwell.com) or by contacting your local Rockwell

    Automation sales office.

    Installing RSTestStand Lite

    To install RSTestStand Lite:

    1. Log onto the computer on which you want to install the emulator as an administrato(or a user with administrative privileges).

    2. Insert the RSLogix Emulate 5000 CD-ROM into the computers CD-ROM drive. Th

    setup program should start automatically. If it does not, open the CD-ROM drive wi

    Windows Explorer and run the AUTORUN.EXE program on that drive.

    3. The Setup program displays a menu of choices. Click Try Out RSTestStand.

    4. The Setup program displays a welcome screen. Click Next.

    5. The Setup program displays the License Agreement for the software. Read the

    agreement carefully. If you choose to adhere to the terms of the agreement, click I

    accept the terms of the license agreement. If you do not accept the terms of the

    license agreement, click Cancel(the Setup program for RSTestStand Lite stops).

    6. The Setup program displays the Customer Information screen. In this screen, enter

    your name, the name of the company you work for.

  • 7/22/2019 RSEMU Getting Results

    10/60

    GETTINGRESULTSWITHRSLOGIXEMULATE5000

    6

    This screen also asks for a serial number. Since you are installing the Lite version o

    RSTestStand, there is no serial number provided with the software, but you will nee

    to enter a ten-digit number in the Serial Number field. (Any ten-digit number will do

    After entering this information, click Next.

    7. The Setup program asks you to choose a setup type. You can choose whether you

    want the Setup program to install RSTestStand Lite to its default folder (\Program

    Files\Rockwell Software\RSTestStand) or to another folder. You can also choose

    whether or not you want to install certain components of RSTestStand Lite.

    If you want to have all components of RSTestStand Lite installed to the default

    folder, click Standard Feature Set Installation to Default Location.

    If you want to choose the folder into which you want to install RSTestStand Lite

    or choose the components you want to install, click Custom Location Selection

    and/or Custom Feature Selection.

    If you chose Custom Location Selection and/or Custom Feature Selection:

    a. Click Next. The Setup program displays the Custom Setup screen.

    http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/
  • 7/22/2019 RSEMU Getting Results

    11/60

    1 INSTALLINGRSLOGIXEMULATE50

    b. By default, all the components of RSTestStand Lite will be installed. Select the

    components you do not want to install, and then click This feature will not be

    available. (You cannot deselect the RSTestStand Lite component.)

    c. To change the folder into which you want to install RSTestStand Lite, click

    Change. The Setup program displays a window that will allow you to select an

    existing folder or create a new folder. Select the folder you want to use, then clicOK.

    4. Click Next. The Setup program displays a window saying it is ready to install the

    software.

    5. Click Install. The Setup program installs the software. When the software is

    installed, the Setup program displays a window saying the InstallShield Wizard is

    complete.

    6. Click Finish. The Setup program closes.

    To deselect a

    component, click the

    icon for the

    component and then

    click This feature

    will not be

    available.

    (You cannot

    deselect the

    RSTestStand Lite

    component.)

    To change the folder into which you want to

    install RSTestStand Lite, click Change.

  • 7/22/2019 RSEMU Getting Results

    12/60

    GETTINGRESULTSWITHRSLOGIXEMULATE5000

    8

    Getting Assistance with RSLogix Emulate 5000

    Online Help

    You can access the online help for RSLogix Emulate 5000 through the Chassis Monitor

    Open the Chassis Monitor and click Help > Help Topics.

    Rockwell Automation Technical Support

    You can contact Rockwell Automation Technical Support by telephone, fax, or by e-ma

    BYPHONE

    To contact Rockwell Automation Technical Support by phone, call 440.646.5800.

    BYFAX

    To contact Rockwell Automation Technical Support by fax, dial 440.646.5801.

    BYE-MAIL

    To contact Rockwell Automation Technical Support by e-mail, send your message to

    [email protected]

    Support Information on the World Wide Web

    To obtain support information from Rockwell Automations World Wide Web site, go to

    http://support.rockwellautomation.com.

    http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/
  • 7/22/2019 RSEMU Getting Results

    13/60

    2 An Overview of RSLogix Emulate 5000RSLogix Emulate 5000 is a software product that emulates the behavior of Logix5000processors. The emulator allows you to experiment with and debug your Logix5000

    programs in a safe, controlled environment without investing in physical controllers and

    I/O modules. Additionally, RSLogix Emulate 5000 allows you to test your HMI

    applications without using a real controller.

    Components of RSLogix Emulate 5000

    There are two components of RSLogix Emulate 5000:

    The Chassis Monitor, which is a software application that allows you to configure

    emulation and simulated I/O modules

    Emulation modules, which are Windows services that simulate the behavior of

    Logix5000 processors and certain I/O modules

    Emulation modules run as Windows services, which are applications that run without

    interfaces of their own. The Chassis Monitor serves as an interface to the emulation

    modules, allowing you to create and configure instances of the modules.

    What RSLogix Emulate 5000 Can and Cannot doRSLogix Emulate 5000 simulates most of the behaviors of Logix5000 processors. Ther

    are exceptions, and you should keep those exceptions in mind as you use the emulator.

    The following table shows the differences between Logix5000 processors and RSLogix

    Emulate 5000.

    Logix5000 processors include: ControlLogix, CompactLogix, FlexLogix, SoftLogix, and

    DriveLogix controllers. For more information about the Logix5000 family of controllers, see the

    Allen-Bradley Web site (http://www.ab.com) or contact your local Rockwell Automation sales

    office.

  • 7/22/2019 RSEMU Getting Results

    14/60

    GETTINGRESULTSWITHRSLOGIXEMULATE5000

    10

    Features: Logix5000 Processor RSLogix Emulate 5000

    Breakpoints and tracepoints Not supported Supporteda

    Control real I/O Supported Not supported

    Forcing Supported Supported

    Interface to non-Rockwell

    Software HMI software

    DDE/OPC (requires RSLinx

    Professional, Single Node, OEM, or

    Gateway)

    DDE/OPC (requires RSLinx

    Professional, Single Node, OEM,

    Gateway)

    Programming languages Ladder diagram, function block,

    sequential function chart, and

    structured text

    Ladder diagram, function block,

    sequential function chart, and

    structured text

    Messaging Supported Supported (local only)

    Motion instructions Supported Supported (virtual axes only)

    Jump to external routines (JXR

    instructions)Supportedb Not supported

    Communications through

    RS232 ports

    Supported Supported

    Communications with RSView Supported Supported

    Time scaling Not supported Supported

    Single Scan Mode Not supported Supported

    Network cards Yes Remote programming only

    Task priority levels 16 3

    Trending Yes Yes

    Online editing of sequential

    function chart and structured

    text programsc

    Yes Yes

    a.Supported only in ladder diagram programming.

    b.Supported only in SoftLogix5800 controllers.

    c.Supported only in version 13.

    Program execution times in RSLogix Emulate 5000 will be different from the times you can

    expect in a Logix5000 processor. Execution times will also vary depending on how many oth

    applications (including other emulation and I/O simulation modules) are running at the same

    time as the emulator. Do not depend on execution time in the emulator as a guide to how

    fast a physical Logix5000 processor will execute the same program!

    http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/
  • 7/22/2019 RSEMU Getting Results

    15/60

    2 ANOVERVIEWOFRSLOGIXEMULATE50

    About Floating Point Calculations and the Emulator

    For maximum portability across platforms, avoid mixed operand types between

    destinations their inputs. If getting identical results for similar operations across language

    is important to you, make sure to perform floating point operations. However, floating

    point operations execute somewhat more slowly than integer operations. There are also

    other considerations, such as how compatible your operands are with that of the I/O bein

    used, and so on. See below for more details on typed operations across Logix platforms

    and across languages.

    Because RSLogix Emulate 5000 is based on open systems technology, the controller

    performs computational operations much the same way as open systems platforms and

    tools do it. This becomes important when performing mixed typed operations such as

    dividing two integers and storing the result in a real.

    Integer operations typically truncate the rational portion of a computation result while

    floating point operations preserve it. For example, when a RSLogix Emulate 5000program performs "a = n / m" where the data types for "a", "n", and "m" are real, intege

    and integer respectively, this specifies an integer divide between "n" and "m" and places

    the answer into "a", performing an integer to real conversion. If "n" = 800 and "m" =

    1000, the result is 0 and gets stored into "a" as 0.0.

    When a ControlLogix program performs the same "a = n / m" where the data types for

    "a", "n", and "m" are real, integer, and integer respectively, this specifies a floating poin

    divide between "n" and "m" and places the answer into "a", with no conversion needed.

    "n" = 800 and "m" = 1000, the result is 0.8 and gets stored into "a" as 0.8. In RSLogix

    Emulate 5000, the input operand types dictate the operation while in ControlLogix, if an

    of the operands are real, a floating point operation is performed. RSLogix Emulate 5000

    performs the operation exactly like a C routine would.

    Typed operations across languages

    There are instruction differences across programming languages as well as across Logix

    platforms. The following examples use the operation "i = n / m" where all the operands

    are integers. Ladder DIV instructions perform an integer divide operation and store the

    immediate result in the destination. For "n" = 800 and "m" = 1000, "i" is equal to 0. The

    DIV function block instructions only does floating point operation. The function block

    instruction converts the inputs to reals (if necessary) and then converts the result from a

    real to the destination type is (if necessary). In this example, "n" is converted to 800.0 an

    "m" is converted to 1000.0. The result of the operation is 0.8. That result then gets

    converted to an integer where rounding rules apply and the final destination value is 1.This difference between ladder and function block instructions applies to all Logix

    platforms. Function block instructions only perform floating point operations.

  • 7/22/2019 RSEMU Getting Results

    16/60

    GETTINGRESULTSWITHRSLOGIXEMULATE5000

    12

    A Brief Outline of Using RSLogix Emulate 5000

    Typically, RSLogix Emulate 5000 is used to check logic (or the logic behind HMI

    systems, etc.) before that logic is put into physical controllers. Heres a brief outline of

    how you can implement RSLogix Emulate 5000 in your project development.

    1. In RSLogix 5000, create a new project using the Emulator processor type.

    2. Set up the projects I/O configuration to match that of the Chassis Monitor,

    configuring I/O simulation modules or additional emulator modules to emulate your

    application.

    3. Develop the logic program for your application, configuring it to run on the emulato

    Use symbolic tags for your I/O points and alias them to simulated I/O modules or

    other emulators (using produced and consumed tags). You can also use tags in

    RSTestStand or RSView to simulate I/O.

    4. Download your program to the emulator and debug it using the tools in RSLogix5000.

    5. After verifying your programs operation with the emulator, save a copy of your

    project for reference.

    6. In RSLogix 5000, change the processor type of your project to use the physical

    processor that will run your application. Reconfigure your projects I/O to use the

    modules for your application.

    7. Re-alias the I/O points in your project to use the I/O modules for your application.

    8. Remove any tracepoint and breakpoint instructions you may have used in the projec

    (these will not work in a physical processor).

    9. Verify your project and correct any errors. You can then download your project to

    your physical controller.

    http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/
  • 7/22/2019 RSEMU Getting Results

    17/60

    3 Using the Chassis MonitorThe Chassis Monitor is a software application used to configure RSLogix Emulate 5000and I/O simulation modules.

    Starting the Chassis Monitor

    There are three methods for starting the Chassis Monitor. You can launch the Chassis

    Monitor from the Windows Start menu, you can click the Chassis Monitor icon on the

    Windows desktop (if you chose to place it there during installation), or you can launch th

    Chassis Monitor from the Windows System Tray.

    Starting the Chassis Monitor from the Start Menu

    To start the Chassis Monitor, click Start > Programs > Rockwell Software > RSLogix

    Emulate 5000 > RSLogix Emulate 5000 Chassis Monitor.

    Starting the Chassis Monitor from the Windows Desktop

    If you chose to place an icon for the Chassis Monitor on the Windows Desktop, you can

    start the Chassis Monitor by double-clicking the icon. The icon looks like this:

    You must use a version of RSLogix Emulate 5000 that matches the version of RSLogix 5000

    used to develop the logic project you want to emulate. For example, if you want to emulate a log

    project developed with version 12 of RSLogix 5000, you must use version 12 of RSLogix Emula

    5000.

    For version 13 of RSLogix 5000 Emulate: Unlike the SoftLogix 5800 controller, RSLogix Emula

    5000 stops and starts with the Chassis Monitor. RSLogix Emulate 5000 does not run when the

    Chassis Monitor is not running.

    For version 12 of RSLogix 5000 Emulate: The emulator starts and stops like a SoftLogix 5800

    controller, operating as a Windows service.

  • 7/22/2019 RSEMU Getting Results

    18/60

    GETTINGRESULTSWITHRSLOGIXEMULATE5000

    14

    Starting the Chassis Monitor from the System Tray

    If the Chassis Monitor is running, you can click the Chassis Monitor icon located in the

    Windows System Tray. (The System Tray is located on the Windows Taskbar. By

    default, the System Tray is in the lower right corner of your computers screen.)

    System Tray Icon Status Indicators

    The System Tray icon indicates the state of the emulators in the Chassis Monitor.

    Navigating in the Chassis Monitor

    The Chassis Monitor is where you can create and configure RSLogix Emulate 5000

    emulation modules and simulated I/O modules. Modules reside in the Chassis Monitorslots, much as they would reside in a physical chassis.

    Menus available at the top of the Chassis Monitor window and from right-clicking slots

    and modules allows you to configure your chassis with the modules you need.

    This icon: Means:

    Normal operation. No faults.

    (Red triangle, white

    exclamation point)

    Major emulator fault. One or more emulators in the Chassis Monit

    has faulted.

    (Yellow triangle, black

    exclamation point)

    Minor emulator fault. I/O not responding.

    For version 13 of RSLogix 5000 Emulate: Unlike the SoftLogix 5800 controller, RSLogix Emula

    5000 stops and starts with the Chassis Monitor. RSLogix Emulate 5000 does not run when the

    Chassis Monitor is not running.

    For version 12 of RSLogix 5000 Emulate: The emulator starts and stops like a SoftLogix 5800

    controller, operating as a Windows service.

    This is the

    Chassis Monitor

    icon in the

    Windows System

    Tray.

    http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/
  • 7/22/2019 RSEMU Getting Results

    19/60

    3 USINGTHECHASSISMONITO

    The RSLinx module represents a communication module for the chassis. This module

    cannot be removed or moved to another slot.

    The following illustration shows a Chassis Monitor window with three emulator and thre

    simulated I/O modules.

    These "slots" hold emulator or

    simulated I/O modules. Click Slot

    > CreateModule to create a

    module.

    This is an

    emulator module.

    This is a simulated I/O module.

    You can click on the module's

    terminal cover to open it.

    The RSLinx

    module in slot 0

    cannot be

    removed.

    The red box surrounding this

    module indicates it is selected

    You can right-click modules to

    display a configuration menu.

    This button allows you to

    contract the Chassis Monitor into

    a smaller display. This smaller

    display hides slots 9 through 16.

  • 7/22/2019 RSEMU Getting Results

    20/60

    GETTINGRESULTSWITHRSLOGIXEMULATE5000

    16

    Creating an Emulation Module

    To create an emulation module:

    1. Click Slot > Create Module.

    2. From the Module Type field, choose the type of module you want to create. Choose

    Emulator RSLogix Emulate 5000 Controller.

    3. In the Slotfield, enter the slot where you want the emulator to reside. The emulator

    can be in any slot (except for slot 0).

    4. Click OK to accept your changes and add the emulator to the virtual chassis.

    You can click Cancelif you wish to cancel creating the emulator.

    5. If you have previously created a emulator module in the same slot and you did not

    delete the configuration for the module when you removed it, the software tells you

    there is previous configuration information for the module. The software asks

    whether you want to use the previous configuration, or reset the configuration to

    default values.

    a. To use the previous configuration, click Use the Configuration from the

    Previous Controller. To reset the configuration, click Reset the Configuration

    to Default Values. (Even if you reset the configuration to its default values, the

    name of the emulator remains the same as the one that was deleted.)

    b. If there was a program in the deleted emulator module, the software shows the

    controller name and the date the program was last downloaded into the controller

    If you want to load this program into the emulator module you are creating, chec

    the Load Saved Controller Image from Previous Instancecheck box.

    c. Click Nextto continue.

    You can have up to 16 emulation modules in the Chassis Monitor at one time. However, you

    computers performance may be impaired significantly if you run multiple emulation modules

    simultaneously.

    If you modify the project to use a physical Logix5000 processor, make sure your rack and slo

    configurations in your project match those in your control system. Otherwise, you may not beable to communicate properly with the physical controller, the physical controller may fault, or

    your control program may have unexpected results.

    Using a previously loaded controller image may result in unexpected operation. Make sure thprogram is correct before running your emulations.

    http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/
  • 7/22/2019 RSEMU Getting Results

    21/60

    3 USINGTHECHASSISMONITO

    4. A configuration wizard appears to allow you to enter module-specific properties. Th

    first screen of the wizard allows you to enter general properties for the emulator.

    5. Click Next. The software displays a window for setting additional features of the

    emulator.

    6. Click Finish. The Chassis Monitor places an emulator module in the slot you

    selected.

    For this: Select or type:

    Startup mode The mode in which you want the emulator to start when it first

    launches. It can start either in Remote Program mode or in whateve

    mode it was in when the emulator service is stopped (when the

    computer was shut down or the emulator was stopped manually).

    Memory size The memory size for the emulator. M ake this equal to the memory si

    of the controller you are emulating.

    Periodic Save Interval Specify whether you want to save the current controller information

    (program, data, and configuration information) periodically, and if s

    specify how often (minutes). The default is enabled for 10 minutes.

    For this: Select or type:

    Continuous Task Dwell Time Specify the timeslice (0-1000 ms) made available for all other

    Windows applications. The default is 10 ms.

    The dwell time is the time between the end of the continuous task an

    the start of the next execution of the continuous task.

    CPU Affinity If you are running the emulator on a computer that has more than on

    CPU, set the CPU that you want to run the emulator (the emulator crun on only one CPU).

    Channel 0 Serial Port If you want to emulate serial communications with a Logix5000

    processor, set the computer serial port that you want to use to emula

    Channel 0 of the Logix5000 processor.

    If you right click on the virtual chassis on the slot where you wish to create your module, and

    then choose Create, the slot number is automatically filled in for you.

  • 7/22/2019 RSEMU Getting Results

    22/60

    GETTINGRESULTSWITHRSLOGIXEMULATE5000

    18

    Configuring the Emulator

    Configuring the emulator is done through the Chassis Monitor.

    Display the Emulator Configuration

    To display the configuration for an emulator:

    1. Open the Chassis Monitor.

    2. Right-click the emulator module for which you want to display the configuration, the

    click Configure Emulation. The Configure Emulation window opens. This windo

    is illustrated below.

    These controls

    allow you to

    control the

    "speed of time"

    These controls

    allow you to

    configure trace

    displays

    Active tracesappear in this list

    This control

    allows you to log

    traces to a file

    http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/
  • 7/22/2019 RSEMU Getting Results

    23/60

    3 USINGTHECHASSISMONITO

    Set the Speed of Time

    The speed of time setting allows you to slow down program execution in the emulator

    When you slow the speed of time, timers slow down, and additional time is added to the

    program scan time, allowing you more time to observe program execution as it happens

    The speed of time is set as a percentage of real time. When the speed of time is set to

    100%, program execution is in real time. Setting the speed of time to another value slow

    program execution by an amount proportional to the percentage you select. For exampl

    setting the speed of time to 60 percent makes actions that normally take one second take

    around 1.67 seconds.

    Changes to the speed of time setting take effect as soon as they are set.

    To set the speed of time:

    1. Open the Chassis Monitor.

    2. Right-click the emulator module for which you want to display the configuration, theclick Configure Emulation. The Configure Emulation window opens.

    3. Set the speed of time using the controls displayed in the window. The illustration

    below shows how the controls work.

    Click this to stop

    program execution

    immediately

    Use the slider to adjust

    the speed of time in one

    percent increments

    Click this to set

    the speed of

    time to 100%

    immediately

    This field shows

    the last value set

    for the speed of

    time

    If you use the slider or

    type a percentage, clickthis button to confirm

    the change

    You can also

    type the

    percentage in

    this field

  • 7/22/2019 RSEMU Getting Results

    24/60

    GETTINGRESULTSWITHRSLOGIXEMULATE5000

    20

    Configure Trace Displays

    When tracepoint and breakpoint instructions execute, the emulator opens a trace display

    To set a trace, program a tracepoint or breakpoint instruction. SeeProgramming

    Breakpoints and Tracepointson page 37for information about programming theseinstructions.

    To configure how the emulator handles and displays these traces:

    1. Open the Chassis Monitor.

    2. Right-click the emulator module for which you want to display the configuration, the

    click Configure Emulation. The Configure Emulation window opens.

    3. Refer to the following table for the settings.

    This setting: Does this:

    Ignore If No Value Changed This button toggles whether the trace displays should record every

    trace or only those traces where there are changes to the value bein

    traced. If the button is indented, the trace displays will ignore thos

    traces where the value does not change.

    TimeStamp Set this to record how you want time recorded in traces.

    Nonerecords no time information in the trace displays.

    Deltarecords the difference between the current trace and the last

    trace.

    Absoluterecords the time that the trace triggered. The time is in th

    number of milliseconds since the computer running the emulator w

    last rebooted.

    Display all new traces Check this box if you want all new traces to display automatically i

    trace window.

    Log new traces to disk Check this box if you want new traces to automatically log to disk.

    Display All Traces Click this button to display all of the current traces in their trace

    windows. (The current traces are listed by name in the Configure

    Emulation window.)

    Close All Traces Click this button to close all of the open trace windows.

    Remove All Traces Click this button to remove all of the current traces from the trace l

    Close Log File Click this button to stop logging traces to a file.

    Trace Log File This field shows the currently set log file. To set the log file, click

    Browse. For more information, seeLog Traces to Diskon page 21

    http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/
  • 7/22/2019 RSEMU Getting Results

    25/60

    3 USINGTHECHASSISMONITO

    Log Traces to Disk

    You can configure the emulator to log traces to a text file. To do this:

    1. Display the emulator configuration.2. Check the Log new traces to disk check box.

    3. Click the Browsebutton.

    4. Select the text file you want to hold trace information. If you want to create a new

    file, type the name of the new file in the File namefield.

    5. Click Open. If the file you selected already has data in it, the software asks if you

    want to append your traces to the end of the file, overwrite the data in the file with th

    traces, or cancel.

    6. Execute your logic. When a TPT instruction executes, the trace information is logge

    to the file you selected.

    7. When you are ready to view the traces stored in the log file, display the emulator

    configuration, then click Close Log File. You can then open the log file in a text

    editor (such as Windows Notepad).

    Creating Simulated I/O

    You can use a 1789-SIM module to simulate discrete I/O with the emulator. (This is the

    only form of I/O you can simulate with the emulator.) This module resides in the Chass

    Monitor and provides sixteen inputs and outputs that you can use in logic programs.

    To create a SIM module in the Chassis Monitor:

    1. In the Chassis Monitor, click Slot > Create Module. The software displays the Sele

    Module window.

    2. In the Select Module window, select the 1789-SIM 32 Point Input/Output

    Simulatorfrom the Module Typelist. Set the Slotfield to the slot number into whic

    you want to place the SIM module. Click OK. The software displays the SelectDevice window.

    3. The Select Device window displays the device serial number (actually the slot

    number for the module).

    You can log data to a file with any extension (or with no extension at all). However, to be able

    view traces with a text editor (such as Windows Notepad), use a TXT file extension.

    If you try to open the log file without closing it in the emulator configuration, you will see an err

    message saying that the file cannot be accessed. You must close the log file in the emulator

    before it can be viewed by another application.

  • 7/22/2019 RSEMU Getting Results

    26/60

    GETTINGRESULTSWITHRSLOGIXEMULATE5000

    22

    a. If you deleted a SIM module from this slot without clearing its configuration, th

    software displays a message saying that previous configuration information exis

    for the module. You can retain the previous configuration, or you can reset the

    configuration to default values. To retain the previous configuration, click Usethe Previous Configuration. To reset the module to its default values, click

    Reset the Configuration to Default Values.

    b. Click Next.

    3. The software displays the General window. In this window, you can label the SIM

    module with a text string that will scroll across the face of the module to help you

    identify it while it is in the Chassis Monitor. Type the name for the module in the

    Label for 1789-SIM Module Marqueefield. (If you do not type a name, the

    software uses the words Simulator Module.)

    Using Produced and Consumed Tags

    Another method for simulating I/O is to use another emulator module to produce and

    consume tags. See Configuring Produced and Consumed Tagson page 34for informatio

    about configuring these tags.

    Configuring the Chassis Monitor

    You can configure the behavior and display of the Chassis Monitor. The following tabl

    shows how to configure the Chassis Monitor.

    To set the Chassis Monitor to: Click this menu option:

    Hide slots 9-16 (if you are not using those slots or you

    simply want the Chassis Monitor to take up less space on-

    screen)

    View > Hide Slots 9-16

    Hide the computer name View > Compact

    Change the rate at which the module display updates Options > Auto Refresh Rate > (High,

    Normal, or Low)

    Keep the Chassis Monitor on top of other windows when

    it is displayed

    Options > Always On Top

    Set the Chassis Monitor to start in a minimized state (the

    window is not opened immediately and the application is

    available from the Windows Taskbar)

    Options > Start Minimized

    Remove the Chassis Monitor from the Windows Taskbar

    when you minimize its window (the Chassis Monitor icon

    remains in the System Tray)

    Options > Hide When Minimized

    http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/
  • 7/22/2019 RSEMU Getting Results

    27/60

    3 USINGTHECHASSISMONITO

    When you delete a module, automatically check the Clear

    Chassis Monitor module configuration check box.

    (If this feature is not set, the software does not

    automatically check that box for you.)

    Options > Clear Configuration on Remove

    To set the Chassis Monitor to: Click this menu option:

  • 7/22/2019 RSEMU Getting Results

    28/60

    GETTINGRESULTSWITHRSLOGIXEMULATE5000

    24

    http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/
  • 7/22/2019 RSEMU Getting Results

    29/60

    4 Connecting the Emulator toRSLogix 5000

    Connecting RSLogix Emulate 5000 to RSLogix 5000 requires making some changes to

    your logic project.

    1. In RSLinx, create a driver for the emulator.

    2. In RSLogix 5000, set your logic project to use the emulator.

    3. Configure communications in the logic project to use the emulator driver.

    4. Add the simulated I/O to your logic project.

    5. Program breakpoint and tracepoint instructions.

    Creating a Communications Driver for the Emulator

    In RSLinx, you need to create a communications driver for RSLogix Emulate 5000. Th

    driver will allow other applications to communicate with the emulator.

    To create the communication driver:

    1. In RSLinx, click Communications > Configure Drivers. The Configure Drivers

    window appears.

    2. Select the Virtual Backplane (SoftLogix 58xx)driver from the Available Driver

    Typeslist.

    3. Click Add New. The Add New RSLinx Driver window appears. This window allow

    you to name the driver. You can keep the default name, or type a name of up to 15

    characters. Click OK.

    4. The new driver appears in the Configured Driverslist. Click Close.

  • 7/22/2019 RSEMU Getting Results

    30/60

    GETTINGRESULTSWITHRSLOGIXEMULATE5000

    26

    Setting a Logic Project to Use the Emulator

    Before you can emulate a logic project, you must configure the project's processor type t

    use the emulator. To do this:

    1. In RSLogix 5000, open the project that you want to emulate.

    2. Click Edit > Controller Properties. The Controller Properties window opens.

    3. On the Generaltab of the Controller Properties window, set the Slotfield to

    correspond with the slot in the Chassis Monitor containing the emulator you want to

    use to emulate the project.

    4. Click Change Type. The Change Controller Type window opens.

    2. ClickAdd New.

    1. Select the Virtual

    Backplane (SoftLogix

    58xx) communications

    driver

    3. Click Close.

    http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/
  • 7/22/2019 RSEMU Getting Results

    31/60

    4 CONNECTINGTHEEMULATORTORSLOGIX50

    5. From the Tolist, select EmulatorRSLogix Emulate 5000 Emulator.

    6. Click OK.

    Configuring Communications in the Logic Project

    Before you can download to or go online with the emulator, you must configure

    communications in your logic project. To do this:

    1. In RSLogix 5000, open the project you want to emulate.

    2. Click Communications > Who Active. The Who Active window opens.

    3. The Who Active window displays a tree of the available network nodes using the

    communication drivers you have configured in RSLinx. In the tree, click the emulat

    you want to use for this project.

    4. Click Set Project Path. This sets the communication path to use the emulator.

    1. Click Change Type.

    2. Select RSLogix

    Emulate 5000

    Controller.

    2. Click OK.

  • 7/22/2019 RSEMU Getting Results

    32/60

    GETTINGRESULTSWITHRSLOGIXEMULATE5000

    28

    http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/
  • 7/22/2019 RSEMU Getting Results

    33/60

    5 Connecting the Emulator to RSViewRSLogix Emulate 5000 uses OLE for Process Control (OPC) to communicate withRSView. Connecting the emulator to an RSView project requires creating an OPC topi

    in RSLinx, then creating a communications node and tags in the RSView project that use

    the OPC topic.

    Please see the documentation for RSView for more information.

    Creating an OPC Topic for the Emulator

    To create an OPC topic for the emulator:

    1. Open the Chassis Monitor, and make sure your emulator is running.

    2. In RSLinx, open an RSWho window (click Communications > RSWho). Theemulator should be visible in the RSWho window. If it is not, make sure there is a

    communication driver for the emulator. See Creating a Communications Driver for

    the Emulatoron page 25for more information.

    3. In the RSWho window, right-click the emulator, then click Configure New DDE/

    OPC Topic. This creates a new OPC topic, and displays the DDE/OPC Topic

    Configuration window with a new topic for the emulator.

    4. Click Done. This closes the DDE/OPC Topic Configuration window and saves the

    topic for your emulator.

    Creating a Communications Node in an RSView ProjectTo create a communications node in RSView that uses the OPC topic for the emulator:

    1. Open your RSView project.

    2. In your projects Systemfolder, open the Nodeeditor. In RSView, a node represents

    communications device, usually a programmable controller or another Windows

    application. In the Node editor, we will create a node that represents the emulator.

  • 7/22/2019 RSEMU Getting Results

    34/60

    GETTINGRESULTSWITHRSLOGIXEMULATE5000

    30

    3. Set up the Node editor window as shown in the following table.

    4. Click Accept. This saves the node configuration.

    For this field or control: Set or enter:

    Data Source OPC Server

    Name Enter a name for the node (representing the emulator). This can be the

    name of the emulator, if you like.

    Enabled Make sure this check box is checked.

    Server Click the button next to the Server Name field, choose RSLinx OPC

    Server, then click OK.

    Type Select In-Process.

    Access Path Leave this blank.

    Update Rate This defaults to 1.000 seconds (one update per second). If you need a fas

    or slower update rate, enter the update frequency.

    1. Click OPC

    Server.

    2. Enter a name

    for the node.

    3. Make sure the Enabled

    checkbox is checked.

    4. Click this button, click

    RSLinx OPC Server,

    then click OK.

    6. Set the Update Rateto

    the frequency at which

    you want data to updateyour RSView project.

    7. Click

    Accep

    5. Make sure In-Process

    is selected.

    http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/
  • 7/22/2019 RSEMU Getting Results

    35/60

    5 CONNECTINGTHEEMULATORTORSVIE

    Adding Tags from Your Logic Project to Your RSView Project

    Once you have created an OPC node for the emulator, you can add tags from your logic

    project to your RSView tag database. To do this:

    1. Open your RSView project.

    2. In your projects Systemfolder, open the Tag Databaseeditor.

    3. In the Data Sourcesection of the Tag Database editor, click Device.

    1. Click Device.

    3. Select the data

    type for the tag.

    2. Click this button and

    select the OPC node

    you created for the

    emulator.

    4. Click this button to

    display the OPCAddress Browser.

    5. Browse for the

    address you want to

    use with the tag in

    this tree.

    6. Select the address.

    7. Click OK.

  • 7/22/2019 RSEMU Getting Results

    36/60

    GETTINGRESULTSWITHRSLOGIXEMULATE5000

    32

    4. Click the button next to the Node Name field. This displays the Node Browser. Sele

    the OPC node you created for the emulator and click OK.

    5. In the Tagsection of the Tag Database editor, select the type of tag you want to creat

    from the Typelist.

    6. In the Data Sourcesection of the Tag Database editor, click the button next to the

    Addressfield. This displays the OPC Address Browser.

    7. In the OPC Address Browser, select the address you want to use with the tag and clic

    OK.

    8. Finish creating the tag by filling in the fields in the Tag Database editor.

    9. Click Accept. The tag is stored in the tag database. You can now use the tag in you

    RSView project.

    For this field or control: Set or enter:

    Name The name of the tag you want to create.

    Security If you have set up security for your RSView project, set the security cla

    associated with the tag.

    Description Type a description of the tag (optional).

    Minimum The minimum value for the tag (as used in RSView).

    Maximum The maximum value for the tag (as used in RSView).

    Scale A scaling value for the tag.

    Offset A value to add to the tag.

    Units The units for the tag.

    Data Type Select the data type for the tag.

    http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/
  • 7/22/2019 RSEMU Getting Results

    37/60

    6 Simulating I/OThere are two methods of simulating I/O with RSLogix Emulate 5000. You can use asimulated I/O module to simulate discrete I/O, or you can use another emulation modul

    to produce and consume tags of any type. You can use both methods simultaneously.

    Configure Simulated I/O in the Logic Project

    To be able to address simulated I/O in your logic project, you must create the simulated

    O modules in the project. These modules are created just like any other I/O modules.

    To create a simulated I/O module in your RSLogix 5000 project:

    1. In RSLogix 5000's Controller Organizer, right click on the I/O Configurationfolde

    and click New Module. The software displays the Select Module Type window.

    2. Select 1789-MODULEfrom the modules list, then click OK.

    3. The software displays the Module Properties window. Enter the following paramete

    for the module:

    4. Specify the connection parameters for the module as shown in the following table.

    Additionally, you can use other software products such as RSView and RSTestStand to simula

    I/O.

    For this parameter: Enter:

    Name A name for the module

    Description (optional) A description of the module and its function in the system

    Comm Format Set this to reflect the type of I/O you are simulating.

    Slot The slot in the virtual chassis that contains the module.

  • 7/22/2019 RSEMU Getting Results

    38/60

    GETTINGRESULTSWITHRSLOGIXEMULATE5000

    34

    5. Click Next. The software displays another Module Properties window.

    6. Specify the Requested Packet Interval (RPI).

    7. Click Finish.

    Configuring Produced and Consumed Tags

    Another method for simulating I/O for your emulated project is to produce and consum

    tags from another emulation module. (See the documentation for your Logix 5000

    processor for background information about produced and consumed tags.)

    Configuring a Produced TagTo configure a produced tag in the emulator:

    1. Open the logic project for the emulator in RSLogix 5000. You must be offline to

    perform this procedure.

    2. In the logic project, open the Controller Tagsfolder. (Produced tags must be scope

    to the controller.)

    For read/write connections: For listen only connections:

    Input Assembly Instance 1 Input Assembly Instance 1

    Input Size 2 Input Size 2

    Output Assembly Instance 2 Output Assembly Instance 3

    Output Size 1 Output Size 1

    Configuration Assembly Instance 16 Configuration Assembly Instance 16

    Configuration Size 0 Configuration Size 0

    You mustenter at least 50.0 ms for the RPI. The connection will fail if the RPI is less than 50ms. Because this module uses the generic module profile, the default RPI is 5.0 ms. You mu

    change this value.

    http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/
  • 7/22/2019 RSEMU Getting Results

    39/60

    6 SIMULATINGI

    3. Right-click the tag you want the emulator to produce, then click Edit Tag Properties

    This displays the Tag Properties window.

    4. In the Tag Properties window, select the Producetag type. Set the number of

    consumers equal to the number of emulators that will consume the tag.

    5. Click OK.

    Configuring a Consumed Tag

    Configuring an emulator to consume a tag is a two-step process. First, you must make th

    emulator that is producing the tag an I/O module of the emulator that will consume the

    tag. Second, you must create a consumed tag to accept the data from the producer.

    MAKINGTHEPRODUCERANI/O MODULEOFTHECONSUMER

    To make the producing emulator an I/O module of the consuming emulator:

    1. Open the logic project for the consuming emulator in RSLogix 5000. You must be

    offline to perform this procedure.

    2. In the logic project, right-click the I/O Configurationfolder, then click New Module

    This displays the Select Module Type window.

    3. In the Select Module Type window, select the Emulatormodule type (RSLogix

    Emulate 5000 Emulator).

    4. Click OK. This displays the Module Properties window.

    5. In the Module Properties window, type the name of the producing emulator in the

    Namefield. Set the slot number for the producing emulator in the Slotfield.

    6. Click Finish. The producing emulator is now an I/O module of the consuming

    emulator.

    CREATINGACONSUMEDTAG

    To create a tag that consumes data from the producing emulator:

    1. In the logic project for the consuming emulator, create a tag (scoped either to the

    processor or to a program). You must be offline to perform this procedure.

    A produced tag must be one of the following data types:

    DINT

    REAL

    an array of DINTs or REALs

    user-defined

    A produced tag must also be less than 500 bytes.

  • 7/22/2019 RSEMU Getting Results

    40/60

    GETTINGRESULTSWITHRSLOGIXEMULATE5000

    36

    2. Right-click the tag you want the emulator to consume, then click Edit Tag

    Properties. This displays the Tag Properties window.

    3. In the Tag Properties window, choose the Consumedtag type.

    4. Select the producing emulator from the Producerdrop-down list box.

    5. Type the name of the tag that the producer is producing in the Remote Tag Name

    field.

    6. In the RPIfield, set the Requested Packet Interval (RPI) to the amount of time (in

    milliseconds) you want the consuming emulator to wait between data requests for th

    tag. This is the minimum rate at which the emulator will consume data.

    7. In the Data Typefield, enter the data type for the consuming tag. This must be thesame data type (including array sizes) as the produced tag it consumes.

    8. Click OK.

    Using RSView or RSTestStand to Simulate I/O

    You can also simulate I/O by using other software packages, such as RSView or

    RSTestStand. RSView is an HMI design and runtime environment, and RSTestStand is

    test stand simulation environment.

    A consumed tag must be of the same data type (including array size) as the produced tag it

    uses. If it is not, the emulator consuming the tag will experience an I/O fault.

    RSTestStand Lite, a demonstration version of the RSTestStand test stand simulation product,

    available from the RSLogix Emulate 5000 installation disk.

    http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/
  • 7/22/2019 RSEMU Getting Results

    41/60

    7 Programming Breakpoints andTracepoints

    Breakpoint and tracepoint instructions allow you to monitor the state of your logic when

    is in conditions that you determine. Breakpoints stop program emulation when a rung i

    true. Tracepoints log data you select when a rung is true.

    Programming Breakpoints

    Breakpoints are programmed with the Breakpoint output instruction (BPT). When the

    inputs on a rung containing a BPT instruction are true, the BPT instruction stops programexecution. The software displays a window indicating that the breakpoint triggered and

    the values that triggered it.

    When a breakpoint triggers, the emulator displays a window informing you that a

    breakpoint occurred. The title bar of the window shows the slot containing the emulato

    that encountered the breakpoint.

    When you click OK, the emulator resumes program execution. If the conditions that

    triggered the breakpoint have not changed, the breakpoint will trigger again.

    In addition, the emulator opens a trace window for the breakpoint. Information about th

    breakpoint and the values it traces are displayed in the trace window.

    Breakpoint and tracepoint instructions are supported only in ladder diagram programs runnin

    in the emulator. These instructions are not supported by physical Logix5000 processors.

    When a breakpoint triggers, you will not be able to edit your project until you permit execution

    continue. You can go online with the emulator to observe the state of your project, but you wil

    not be able to edit it. If you try to accept a rung edit while a breakpoint is triggered, you will see

    dialog box saying the controller is not in the correct mode.

  • 7/22/2019 RSEMU Getting Results

    42/60

    GETTINGRESULTSWITHRSLOGIXEMULATE5000

    38

    Programming the BPT instruction

    The Breakpoint (BPT) instruction has two kinds of parameters:

    You can display a large number of tag values with the BPT instruction, however, theformatting string can contain only 82 characters. Because two characters are required in

    the formatting string for each tag you want in the breakpoint, the maximum number of

    tags you could trace with a single BPT instruction is 41. However, you will probably wa

    to include spaces and other formatting to separate tag data in your traces, so the resultin

    number of tag values that can be effectively displayed by one BPT instruction is

    significantly lower than 41.

    EXAMPLE:

    The following rung shows a breakpoint that stops program execution when an analog

    value is greater than 3.02 or less than 2.01.

    We want to display the breakpoint information in a particular format. That format is

    contained in the Format string (myformat). In this case, the format string contains the

    following text:

    This parameter: Contains: Requires:

    Format A string that sets the formatting for the

    text that appears in the trace window for

    the breakpoint.

    A STRING tag. See String Formats for

    Tracepoint and Breakpoint Instructionso

    page 41.

    Trace This: The tag that has a value you want to

    display in the trace window.

    An INT, BOOL, SINT, DINT or REAL t

    You cannottrace tag structures (such as

    entire timers, counters, etc.). However, y

    can trace individual structure members.

    http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/
  • 7/22/2019 RSEMU Getting Results

    43/60

    7 PROGRAMMINGBREAKPOINTSANDTRACEPOIN

    Breakpoint:The input value is %f

    When the breakpoint triggers, the breakpoint trace window shows the characters before

    the colon (Breakpoint) in the title bar of the trace window. The other characters make

    up the traces. In this example, %f represents the first (and in this case, the only) tag to b

    traced (analogvalue). (See String Formats for Tracepoint and Breakpoint Instructions

    on page 41 for more information about formatting strings. The resulting traces appear a

    shown in the following illustration.

    Programming Tracepoints

    Tracepoints are programmed with the tracepoint output instruction (TPT). When the

    inputs on a rung containing a TPT instruction are true, the TPT instruction writes a trace

    entry to a trace display or log file. (To configure how traces are displayed or logged, se

    Configure Trace Displayson page 20.)

    Programming the TPT Instruction

    The tracepoint (TPT) instruction has two kinds of parameters:

    This parameter: Contains: Requires:

    Format A string that sets the formatting for the

    trace reports (both on-screen and logged

    to disk).

    A STRING tag. SeeString Formats for

    Tracepoint and Breakpoint Instructionso

    page 41.

    Trace This: The tag you want to trace. An INT, BOOL, SINT, DINT or REAL t

    You cannottrace tag structures (such as

    entire timers, counters, etc.). However, ycan trace individual structure members.

  • 7/22/2019 RSEMU Getting Results

    44/60

    GETTINGRESULTSWITHRSLOGIXEMULATE5000

    40

    You can trace a large number of tags with the TPT instruction, however, the formatting

    string can contain only 82 characters. Because two characters are required in the

    formatting string for each tag you want to trace, the maximum number of tags you could

    trace with a single TPT instruction is 41. However, you will probably want to includespaces and other formatting to separate tag data in your traces, so the resulting number o

    tags that can be effectively traced by one TPT instruction is significantly lower than 41.

    EXAMPLE:

    The following rung triggers a trace of three analog values when any one of them exceed

    a given value (30.01).

    We want to display the tracepoint information in a particular format. That format is

    contained in the Format string (myformat). In this case, the format string contains the

    following text:

    Analog inputs trace:Analog inputs = %f, %f, and %f

    When the tracepoint triggers, the characters before the colon (Analog inputs trace)

    appear in the title bar of the trace window. The other characters make up the traces. In

    this example, the %f characters represent the tags to be traced (analogvalue1,analogvalue2, and analogvalue3). (See String Formats for Tracepoint and

    Breakpoint Instructionson page 41 for more information about formatting strings.

    http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/
  • 7/22/2019 RSEMU Getting Results

    45/60

    7 PROGRAMMINGBREAKPOINTSANDTRACEPOIN

    The resulting traces appear as shown in the following illustration.

    When this trace is logged to disk, the characters before the colon appear in the traces.

    This indicates which tracepoint caused which trace entry. The following is an example o

    a trace entry. Analog inputs trace: is the heading text from the tracepoint's format

    string.

    Analog inputs trace:Analog inputs = 31.00201, 30.282000, and 30.110001

    String Formats for Tracepoint and Breakpoint Instructions

    The Format string in the tracepoint and breakpoint instructions allows you to control ho

    the traced tags appear in the traces or breakpoint windows. The format of the string is afollows:

    heading:(text)%(type)

    where headingis a text string identifying the tracepoint or breakpoint, textis a string

    describing the tag (or any other text you choose), and %(type) indicates the format of th

    tag. You need one type indicator for each tag you are tracing with the tracepoint or

    breakpoint instruction.

    For example, you could format a tracepoint string like this:

    My tracepoint:Tag 1 = %e and Tag 2 = %d

    The %e formats the first traced tag as double-precision float with an exponent, and %d

    formats the second traced tag as a signed decimal integer. See the table below for moreinformation.

  • 7/22/2019 RSEMU Getting Results

    46/60

    GETTINGRESULTSWITHRSLOGIXEMULATE5000

    42

    In this case, you would have a tracepoint instruction that has two Trace This parameters

    (one for a REAL and one for an INT, although the value of any tag can be formatted wit

    any flag).

    The resulting tracepoint window that would appear when the tracepoint is triggered woulook like:

    Types for Formatting Tag Values

    The following table shows the available types for formatting tag values. Any type can b

    used for formatting any tag. (The types are similar to those used by the C++ printf

    function.)

    This type: Formats the tag value as: Example:

    %d Signed decimal integer. REAL values are

    truncated.

    45.3202 is rendered as 45.

    %o Unsigned octal integer. Non-octal values are

    converted to octal. REAL values are truncated.

    45.3202 is rendered as 55.

    The text for the INT

    (represented in the

    format string as %d)

    appears here

    The text for the REAL

    (represented in the

    format string as %e)

    appears here

    The heading (the text

    before the colon in the

    format string) appears

    here

    The slot number

    indicates the slot

    containing the

    emulator module that

    has the tracepoint or

    breakpoint being

    traced in the trace

    window

    http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/
  • 7/22/2019 RSEMU Getting Results

    47/60

    7 PROGRAMMINGBREAKPOINTSANDTRACEPOIN

    Using Trace Windows

    Opening and Closing Trace Windows

    By default, tracepoint and breakpoint windows display automatically when a tracepoint o

    breakpoint instruction first executes. (You can configure the emulator to not display thes

    windows automatically. See Configure Trace Displayson page 20 for more information

    about configuring the behavior of trace displays.)

    If you close a tracepoint or breakpoint window, it is still available to you. You can acce

    active traces through the Configure Emulation window (right-click the emulator, then

    click Configure Emulation). The Configure Emulation window allows you to performthe following operations on trace windows:

    %x Unsigned hexadecimal integer with letters

    rendered in lowercase. Non-hex values are

    converted to hex. REAL values are truncated.

    45.3202 is rendered as 2d.

    %X Unsigned hexadecimal integer with letters

    rendered in uppercase. Non-hex values are

    converted to hex. REAL values are truncated.

    45.3202 is rendered as 2D.

    %e Signed floating point value with exponent. The

    exponent delimiter (e) is rendered in lowercase.

    45.320200 is rendered as

    4.532020e+001.

    %E Signed floating point value with exponent. The

    exponent delimiter (E) is rendered in uppercase

    45.320200 is rendered as

    4.532020E+001.

    %f Signed floating point value without exponent. 45.320200 is rendered as

    45.320200.

    %g Signed floating point value in %e or %f

    format, whichever results in a more compact

    display. Trailing zeros are truncated, and the

    decimal point appears only if one or more digits

    follow it. The exponent delimiter (e) is rendered

    in lowercase (when it is appropriate).

    45.320200 is rendered as 45.320

    433222556.34322 is rendered as

    4.3323e+008.

    %G Signed floating point value in %e or %f

    format, whichever results in a more compact

    display. Trailing zeros are truncated, and the

    decimal point appears only if one or more digits

    follow it. The exponent delimiter (E) is rendered

    in uppercase (when it is appropriate).

    45.320200 is rendered as 45.320

    433222556.34322 is rendered as

    4.3323E+008.

    This type: Formats the tag value as: Example:

  • 7/22/2019 RSEMU Getting Results

    48/60

    GETTINGRESULTSWITHRSLOGIXEMULATE5000

    44

    To perform this function: Do this:

    Have traces automatically open whenever a new

    tracepoint or breakpoint instruction executes.

    Check the Display all new tracescheck box.

    Open an active trace. Double-click the trace name.

    Open all active traces. Click Display All Traces.

    Close all open trace windows. Click Close All Traces.

    Remove all active traces from the trace list. Click Remove All Traces.

    Click Display All

    Tracesto open all of

    the active traces

    Check Display all new

    tracesto automatically

    display trace windows

    when new tracepoints orbreakpoints execute

    Active traces

    appear in this list

    -- double-click a

    trace to display it

    Clicking Close All

    Tracescloses all open

    trace windows

    Click Remove All

    Tracesto remove all

    active traces

    http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/
  • 7/22/2019 RSEMU Getting Results

    49/60

    7 PROGRAMMINGBREAKPOINTSANDTRACEPOIN

    Trace Window Controls

    Trace windows have several controls that allow you to control their behavior.

    This button: Does this:

    Freeze Display Stops the trace window from updating. Use this when you want to read

    values from a rapidly updating trace.

    Clear Display Clears traces from the trace window.

    Freeze Log When you are logging a trace to disk, this button stops and starts logging

    When the button is pressed, logging stops. If you are not logging the

    trace to disk, this button has no effect.

    Click Clear Displayto

    clear the traces from

    the window

    Click Freeze Displayto

    stop the trace window

    from updating

    Click Freeze Logto

    stop logging the trace

    to disk.

  • 7/22/2019 RSEMU Getting Results

    50/60

    GETTINGRESULTSWITHRSLOGIXEMULATE5000

    46

    http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/
  • 7/22/2019 RSEMU Getting Results

    51/60

    8 Software ActivationRockwell Software uses activation files to provide copy protection for its Windows-basesoftware packages. These activation files reside on the Activation disk. During

    installation, the software prompts you to insert the Activation disk and move the

    activation key from the disk to the drive where you are installing RSLogix Emulate 500

    About the Activation Disk

    RSLogix Emulate 5000 comes with a separate Activation disk that activates the softwar

    Without activation, the software will not run.

    The activation file on the Activation disk contains:

    An activation key, which is the software that activates RSLogix Emulate 5000.

    Depending on your requirements, the Activation disk will have one or more activatio

    keys. For example, if your company purchases four RSLogix Emulate 5000

    installations, the Activation disk will contain four keys. Multiple copies of the same

    software require activation keys with matching serial numbers. All of the activation

    keys can be on the same Activation disk.

    A file called EVMOVE.EXEthat moves activation keys to and from computers

    A file called RESET.EXEthat reactivates a damaged activation key

    You can move activation keys off and on the Activation disk. The files EVMOVE.EXE

    and RESET.EXE always stay on the Activation disk.

    Two Methods for Activating RSLogix Emulate 5000

    Depending on your needs, you can activate the software from a:

    Diskette drive. Use this method if you will typically use the software on more than

    one computerfor example, if you want to run the software on a desktop computer

    and a portable computer.

    Hard drive. Use this method if you will typically use the software on only one

    computer. This is the default method if you activate the software during installation

    To run the software on a different computer, move the activation key back to the

    Activation disk, and then reactivate the software.

  • 7/22/2019 RSEMU Getting Results

    52/60

    GETTINGRESULTSWITHRSLOGIXEMULATE5000

    48

    Using the Activation Disk as an Activation Key

    To use the activation key from a diskette drive, modify the ROCKSOFT.INIfile so that

    RSLogix Emulate 5000 searches the diskette drive for the activation key. Once you

    modify this file, you must use the Activation disk each time you start the software.

    TOMODIFYTHEROCKSOFT.INI FILE

    1. Install RSLogix Emulate 5000 as described in Chapter 1.

    2. When the Activation window opens, click Cancelto bypass the activation procedur

    3. Locate the directory containing the ROCKSOFT.INI file (the directory where

    Windows is installed, typically C:\WINNT).

    4. Open the ROCKSOFT.INI file.

    5. Locate the string that says: KEYDISK=FALSE. (If this string is not present, add it t

    the end of the file.)

    6. Edit this string so it says: KEYDISK=TRUE.

    7. Save and close the ROCKSOFT.INI file.

    TOACTIVATERSLOGIXEMULATE5000

    1. Insert the Activation disk into the diskette drive.

    2. Start RSLogix Emulate 5000.

    RSLogix Emulate 5000 automatically searches the diskette drive for the activation

    key.

    MOVINGACTIVATIONKEYSBACKTOTHEACTIVATIONDISK

    You can move activation keys from the hard drive back to the Activation disk at any tim

    Move activation back to the Activation disk:

    to run the software on a different computer

    before installing or using software that could damage the activation files (see

    Protecting Your Activation Fileson page 50for a list of operations that can damage

    activation)

    before sending the computer to a technician

    TOMOVEACTIVATIONKEYSBACKTOTHEACTIVATIONDISK

    1. Insert the Activation disk in a diskette drive.

    2. In Windows, run the EVMOVE program from the Activation disk. The EvMove

    window appears.

    http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/
  • 7/22/2019 RSEMU Getting Results

    53/60

    8 SOFTWAREACTIVATIO

    3. In the EvMove window, select the drive where the activation key is currently stored

    the Frombox. In the Tobox, select the drive containing the Activation disk. Click

    OK.

    4. Do one of the following:

    To move activation keys for all installations, click Move.

    To change the number of activations to move to the Activation disk, select

    RSLogix Emulate 5000, and then click the Edit Selectedbutton. In the Movebo

    type the number of activation keys to move. Click OK, and then click Move.

    5. To close the EvMove Summary box, click OK.

    Activating RSLogix Emulate 5000 after Installation

    You might need to reactivate RSLogix Emulate 5000 after moving activation keys back t

    the Activation disk or after resetting a damaged activation key. To reactivate the softwaryou move the activation key from the Activation disk back to the hard drive.

    By default, when you move activation to a hard drive from the Activation disk, the

    software moves only one activation key for the software. However, when moving to a

    network drive, the software moves all activation keys by default. When reactivating the

    software, you can accept a default or choose the number of activation keys to move.

    To Reactivate RSLogix Emulate 5000

    1. Insert the Activation disk in a diskette drive.

    2. In Windows, run the EVMOVE program from the Activation disk. The EvMove

    window appears.

    3. In the EvMove window, select the drive containing the Activation disk in the From

    box. In the Tobox, select the drive to which you want to move the activation. Click

    OK.

    4. Do one of the following:

    To move activation keys for all installations, click Move.

    To change the number of activations to move to the Activation disk, select

    RSLogix Emulate 5000, and then click the Edit Selectedbutton. In the Movebo

    type the number of activation keys to move. Click OK, and then click Move.

    5. To close the EvMove Summary box, click OK.

  • 7/22/2019 RSEMU Getting Results

    54/60

    GETTINGRESULTSWITHRSLOGIXEMULATE5000

    50

    Protecting Your Activation Files

    Performing certain operations on the hard drive can damage activation files. Always mov

    activation from the hard drive back to the Activation disk before doing any of the

    following. After completing the operation, it is safe to move the activation back to the

    hard drive and reactivate the software.

    Move activation files back to the Activation disk before:

    Upgrading or installing the computers operating system.Upgrading, installing,

    and uninstalling operating system software or networking system software can

    damage the activation files.

    Compressing or decompressing the computers hard drive. Compressing the har

    drive with some compression software programs can damage activation software. In

    addition, decompressing a hard drive with activation files on the compressed drive ca

    damage activation.

    Reactivating a Damaged Activation Key

    If the activation key becomes damaged for any reason, contact Rockwell Software

    Technical Support for a reset code. Our World Wide Web address and telephone number

    appear on the inside front cover of this book.

    When You Call

    When you call or access our web site, you should be at a computer with the Activation

    disk available. You do not have to use the same computer where your software is installe

    However, you must have the Activation disk with a serial number that matches the copy o

    RSLogix Emulate 5000 you want to reactivate.

    The support representative will explain how to find the product ID and system ID from

    the Activation disk and then will assign a reset code for the activation key. After obtainin

    a reset code from Rockwell Software Technical Support, reset the key, and then reactiva

    the software.

    To Reactivate a Key with a Reset Code

    1. Insert the Activation disk in a diskette drive.

    2. In Windows, run the RESET program from the Activation disk. The Reset windo

    appears.

    3. In the Reset Codebox, type the reset code, and then click OK.