Product Catalogue 2004 Safety Relays UE 10 – UE 48 Series

Upload: vobao

Post on 14-Feb-2018

235 views

Category:

Documents


10 download

TRANSCRIPT

Page 1: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

Pro

du

ct

Ca

talo

gu

e 2

00

4

Safety Relays

UE 10 – UE 48 Series

Page 2: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

2 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03

UE 10 - UE 48 Safety Relays

Selection Table

Single Channel Input

UE 23-2 MF

UE 43-2 MF

UE 43-3 MF

UE 43-6 MF

UE 45-3 S1 2 31 Output

up to 3 s Off-Delay

UE 45-3 S1 2 301 Output

up to 30 s Off-Delay

UE 42-2 HD

UE 44-3 SL 2 31 Output

up to 3 s On-Delay

UE 44-3 SL 2 301 Output

up to 30 s On-Delay

UE 48-2 OS

UE 48-3 0S

Dual Channel Input

UE 10-3 OS

UE 11-4 DXOff-Delay

0.5, 1, 2, 3 s

Expansion unit

Stop Cat.

0

Stop Cat.

1

Dual Channel Input

Dual Channel Input

Dual Channel Input

Dual Channel Input

Stop Cat.

0

Stop Cat.

0

Stop Cat.

0

Stop Cat.

0

UE 10-4 XT

2

1

2

1

3

1

6

4

3

0

3

0

3

0

3

0

2

1

3

1

2

1

3

0

4

2

4

2

1)

1) Safety switch with mechanical locking

Main Application Mode Features UE-Unit

Page 3: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 38 009 607/18-09-03

UE 10 - UE 48 Safety Relays

Contents

Dimensional drawings ............................................................ 4

Technical Notes ........................................................................ 6

UE 10-3 OSSafety Relay for opto-electronic

protection systems ............................................................................ 7

UE 10-4 XT und UE 11-4 DXExpansion Modules

(UE 10 without Delay, UE 11 with Off-Delay) ................ 11

UE 23-2 MFSafety Relay for Emergency Stop and

Safety Switch applications ........................................................ 15

UE 42-2 HDSafety Relay for two-hand operation ................................. 19

UE 43-2 MFSafety Relay for Emergency Stop and

Safety Switch applications ........................................................ 23

UE 43-3 MFSafety Relay for Emergency Stop and

Safety Switch applications ........................................................ 27

UE 43-6 MFSafety Relay for Emergency Stop and

Safety Switch applications ........................................................ 31

UE 44-3 SLSafety Relay with On-Delay option for

Emergency Stop and Safety Switch applications ........ 35

UE 45-3 S1Safety Relay with Off-Delay option for

Emergency Stop and Interlock applications .............. 39

UE 48-2 OS und UE 48-3 OSSafety Relay for Emergency Stop, Safety Switch,

Safety Mats and ESPE applications .................................... 43

Operating data ........................................................................ 47

Glossary ..................................................................................... 48

Safety Navigator .................................................................... 49

Sample Wiring Diagrams.................................................... 50

USC USC

Page 4: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

4 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03

Housing A

78

93.3

96.5

22

.59

3.7 1

14

107.

6

58

A.2 Housing (removable terminals)

A.1 Housing (screw type terminals)

UE 10 - UE 48 Safety Relays

82.5

93.3

96.5

48.3

66.7

75

.32

2.5

93

.6 11

4

107.

6

63

Dimensions in mm

Page 5: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 58 009 607/18-09-03

B Housing (screw type terminals)

For mounting rail EN 50 022

3.8

120.5

107

52

.5

75

45

UE 10 - UE 48 Safety Relays

Housing B, C and D

90

52

.5

75

3.8

120.5

107

for mounting rail EN 50 022

C Housing (screw type terminals)

75.5

12

3

96

61

.2

93.5

71.5 22.5

76.5

55.5

D Housing (screw type terminals)

Dimensions in mm

Page 6: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

6 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03

Safety Switch

Emergency Stop

Automatic Reset

Manual Reset

Safety Laser Scanner

Safety Light Curtain

1 Normally closed (NC)

input

1 Normally open (NO)

input

On-delay

Symbols

Off-delay

Technical Explanations

Function Applications

Reset

EDM External device

monitoring

UE 10 - UE 48 Safety Relays

Safety Mat

Two-hand Controls

Safety Locking Device

Page 7: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 78 009 607/18-09-03

UE 10-3 OS Series

EDM

EDMwithin protective

device

UE 10-3 OSSafety Relayfor opto-electronic protective equipment

3

1

<

7

EN 954-1 Same as protective

device

EN 61 496 Types 2, 3, 4

USC

Application

The UE 10-3 OS Safety Relay is a relay module for:

� Electro-Sensitive Protective Equipment (ESPE) with monitored

semiconductor outputs, integral external device monitoring (EDM)

and Restart Inhibit, such as

C 4000

C/M 2000

MSL

S 3000

� Safety systems with monitored semiconductor outputs, integral

external device monitoring and Restart Inhibit, such as LSI and

LE 20

Features

� Single- or dual-channel control

� NC contact for external device monitoring (EDM)

� Outputs: 3 normally open contacts, 1 normally closed contact

� 2 LEDs for relays K 1 and K 2

� Increase in the number of outputs by way of the expansion units

UE 10-4 XT

UE 11-4 DX

� Available with removable terminals (key coded)

� “A“ Housing (see Page 4), width: 22.5 mm

See Pages 51 and 52 for sample wiring diagrams

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice8 009 607/18-09-03

oder

S 3000

C 4000

or

Page 8: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

8 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03

Function

If the semiconductor outputs of the installed safety

device (e. g. C 4000, S 3000) are energised, then the

safety output contacts will close.

When at least one of the semiconductor outputs of the

safety device becomes de-energised, then the output

contacts revert back to open circuit status.

If Restart Inhibit is needed, then this is achieved in the

safety device, for example C 4000 or S 3000.

External device monitoring (EDM)Safety Category 3 or 4 requires monitoring of

contactors. This is provided in the connected protective

device, for example in the C 4000 or S 3000. The

normally closed contact (Y 1 - Y 2) in the UE 10-3 OS

unit is, however, a part of this contactor monitoring

system.

The UE 10-3 OS 2 unit has screw type terminals.

The UE 10-3 OS 3 unit has removable terminals.

Internal Circuitry UE 10-3 OS

K 1

K 2

B1 B2

14 24 34 B4

B3 B4

CH 2

CH 1

13 23 Y1 Y2 B3B1

41 42

33

B2

24

2313

14

Y1

Y2

41

42 34

33

UE 10-3 OS Series

Page 9: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 98 009 607/18-09-03

UE 10-3 OS Series

Technical Data UE 10-3 OS

min. typ. max.

General System Data

Supply voltage to B 1 - B 2, B 3 - B 4Electrical output circuit > 25 V AC / 60 V DC PELVElectrical output circuit < 25 V AC / 60 V DC PELV or SELV

Inputs B 1 ... B 4

Activation time 40 ms

Switch-on voltage 15 V 24 V 30 V

Switch-on current 500 mA

Output circuits (13 - 14, 23 - 24, 33 - 34, 41 - 42, Y 1 - Y 2)

Response time (K 1 / K 2) 20 ms

Relay contacts 3 Normally open contacts (NO), safety relevant1 Normally closed contact (NC), not safety relevant1 Normally closed contact (NC), contactor monitoring

Contact type positively guided

Contact material Silver alloy; gold-plated

Load capacity of contactsSwitching voltage 10 V AC/DC 230 V AC / 30 V DCSwitching current 10 mA 6 ATotal current across all contacts 12 A

Application Category to EN 60 947-5-1 AC-15 Ue 230 V AC, Ie 4 A (360 c/h)

AC-15 Ue 230 V AC, Ie 3 A (3600 c/h)

DC-13 Ue 24 V DC, Ie 4 A (360 c/h)

DC-13 Ue 24 V DC, Ie 2.5 A (3600 c/h)

Permitted switching frequency 3600 c/h

Service life, mechanical (switching cycles) 1 x 107

Service life, electrical (dependent on the load) 2 x 106

Operating data see Page 47

Weight 0.2 kg

Page 10: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

10 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03

Order reference list for UE 10-3 OS

Type Outputs Connections Without actual Order No.

Screw type terminals Removable terminals supply voltage

UE 10 - 3 OS 2 D0 6 024 917

UE 10 - 3 OS 3 D0 6 024 918

UE 10-3 OS Series

Page 11: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 118 009 607/18-09-03

UE 10-4 XT and UE 11-4 DXExpansion modules

z. B. UE 43 - 3 MFBasis-Gerät

UE 10 - 4 XTUE 11 - 4 DXErweiterungsmodul

+

11

EN 954-1 Same as the main unit

4

2

UE 10-4 XT and UE 11-4 DX Series

USC

Application

The UE 10-4 XT and UE 11-4 DX expansion modules

serve to

� Increase the number of output contacts of a main

unit

� UE 11-4 DX has off-delayed outputs (0.5, 1, 2,

3 sec, depending on model)

Features

� NC contact for external device monitoring (EDM)

� Outputs: 4 normally open contacts, 2 normally closed

contacts

� 2 LEDs for relays K 1 and K 2

� Available with removable terminals (key coded)

� “A” Housing (see Page 4), width: 22.5 mm

EDM withinthe main unit EDM

USC

e. g.UE 43-3 MFMain Unit

UE 10-4 XTUE 11-4 DXExpansion module

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice8 009 607/18-09-03

Page 12: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

12 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03

Function

The supply voltage of the expansion module is linked to

an output contact of a main unit.

Upon applying the supply voltage to terminals A 1 and

A 2, relays K 1 and K 2 are energised (the LEDs for

both relays illuminate): The 4 ouput contacts close, the

two normally closed contacts and the EDM (feedback)

circuit switch to open circuit status.

When the output contacts of the standard unit opens

(e.g. by activation of the Emergency Stop), the relays

K 1 and K 2 de-energise: The normally open contacts

open, and the two normally closed contacts close.

External device monitoring (EDM)If external device monitoring is implemented in the

connected main unit, then the normally closed contacts

(Y 1 - Y 2) prevent the resetting of the main unit, when

K 1 and/or K 2 do not de-energise.

The function of the UE 11-4 DX ...... corresponds to that of the UE 10-4 XT, but the unit

also has fixed switch off-delay times of 0.5 sec, 1 sec,

2 sec and 3 sec, depending on the model. They are

achieved by means of capacitors, so that even in the

event of power supply failure the off-delay runs its full

duration in each instance. The delay cannot be

prematurely cancelled. Only after the delay periods have

expired do the relays K 1 and K 2 return to their neutral

rest position.

With the combination of UE 11-4 DX and a main unit,

Stop Category 1 (EN 418) can be realised.

Units ... XT 2 and ... DX 2 have screw type terminals,

Units ... XT 3 and ... DX 3 have removable terminals.

UE 10-4 XT and UE 11-4 DX Series

Internal Circuitry of the UE 10-4 XT and UE 11-4 DX

A1 A2 4727 3717 55 65Y1

4828 3818 56 66Y2

K1

K2

Y1 13 23 33 43 51 61

Y2 14 24 34 44 52 62

A1 A2

K2

K1

UE 10-4 XT

UE 11-4 DX

Page 13: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 138 009 607/18-09-03

UE 10-4 XT and 11-4 DX Series

Technical Data UE 10-4 XT and UE 11-4 DX

min. typ. max.

General System Data

Supply voltage to A 1 - A 2Electrical output circuit > 25 V AC / 60 V DC PELVElectrical output circuit < 25 V AC / 60 V DC PELV or SELV

Supply voltage VV

(A 1 - A 2)UE 10-4 XT 20.4 V AC/DC 24 V AC/DC 26.4 V AC/DCUE 11-4 DX 20.4 V DC 24 V DC 26.4 V DC

Power consumptionAC (UE 10-4 XT only) 2.7 VADC UE 10-4 XT / UE 11-4 DX 1.5 W / 2.0 W

Residual ripple in DC mode(within the limits of V

V) 2.4 V

PP

Nominal frequency in AC mode (UE 10-4 XT) 50 Hz 60 Hz

Activation time (after applying the supply voltage)UE 10-4 XT 25 msUE 11-4 DX 75 ms

Output circuitsUE 10-4 XT (13 - 14, 23 - 24, 33 - 34, 43 - 44, 51 - 52, 61- 62, Y 1 - Y 2)UE 11-4 DX (17 - 18, 27 - 28, 37 - 38, 47 - 48, 55 - 56, 65 - 66, Y 1 - Y 2) off-delayed

Response time of UE 10-4 XT (K 1 / K 2) 40 ms

Switch-off delay time of UE 11-4 DX (depending on type) 0.5, 1, 2 or 3 secInfluence of the supply voltage 0.5 (%/% ∆UN)Influence of ambient temperature 0.4 (%/K)Mean value of error (% + ± 10 ms) ± 20Dispersion (% + ± 10 ms) ± 2

Relay contacts 4 Normally open contacts (NO), safety relevant2 Normally closed contacts (NC), not safety relevant1 Normally closed contact (NC), contactor monitoring

Contact type positively guided

Contact material Silver alloy; gold-plated

Load capacity of contactsSwitching voltage 10 V AC/DC 230 V AC / 30 V DCSwitching current 10 mA 6 ATotal current across all contacts 12 A

Application Category to EN 60 947-5-1AC-15 Ue 230 V AC, I

e 6 A (3600 c/h)

DC-13 Ue 24 V DC, Ie 6 A (360 c/h)

DC-13 Ue 24 V DC, Ie 3 A (3600 c/h)

Permitted switching frequency 3600 c/h

Service life, mechanical (switching cycles) 1 x 107

Service life, electrical (dependent upon loading) 2 x 106

Operating data see Page 47

Weight 0.2 kg

Page 14: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

14 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03

Order reference list for UE 10-4 XT

Type Output Connections Supply voltage Order No.

Screw type terminals Removable terminals 24 V AC/DC

UE 10 - 4 XT 2 D2 6 024 919

UE 10 - 4 XT 3 D2 6 024 920

Order reference list for UE 11-4 DX (with off-delayed outputs)

Typ Output Connections Supply voltage Delay in Order No.

Screw type terminals Removable terminals 24 V DC in secs.

UE 11 - 4 DX 2 D3 0.5 6 024 921

UE 11 - 4 DX 2 D3 1 6 024 922

UE 11 - 4 DX 2 D3 2 6 024 923

UE 11 - 4 DX 2 D3 3 6 024 924

UE 11 - 4 DX 3 D3 0.5 6 024 925

UE 11 - 4 DX 3 D3 1 6 024 926

UE 11 - 4 DX 3 D3 2 6 024 927

UE 11 - 4 DX 3 D3 3 6 024 928

UE 10-4 XT and 11-4 DX Series

Page 15: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 158 009 607/18-09-03

UE 23-2 MF Series

UE 23-2 MFSafety RelayManual or Automatic Reset

EDM

EDM

EN 954-1 Up to Category 4 1)

2

1

oder

USC

15

1) The wires for the input and output signals shall be routed outside the control

cabinet according to the safety category to be used

or

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice8 009 607/18-09-03

Application

The UE 23-2 MF Safety Relay serves as a monitoring

module for:

� Emergency Stops (EN 418): for single- or dual-

channel use

� Safety Switches (EN 1088): for single- or dual-

channel use, e. g. on movable guards

Features

� Single-channel control

� Outputs: 2 normally open contacts, 1 normally closed

contact

� 2 LEDs: supply voltage, relays K 1, K 2

� Manual Reset

� Automatic Reset

� Increase in the number of outputs by way of the

expansion units UE 10-4 XT, UE 11-4 DX

� External device monitoring (EDM)

� Protection Class 2 to EN 50 178

� “D“ Housing (see Page 5), width: 22.5 mm

See Page 53 for sample wiring diagram

Page 16: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

16 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03

UE 23-2 MF Series

Function

After applying the supply voltage (LED SUPPLY illumi-

nates), the normally open contacts remain in the open

state. If the connected sensor is not activated (i.e. the

input circuits are closed), then the normally open

contacts close immediately in Automatic Reset (LED

“K 1, K 2“ illuminate). In the case of Manual Reset,

this only occurs after pressing the Reset button.

External device monitoring (EDM)The unit can take over the function of external device

monitoring. The contactor monitoring system monitors

the external relays through their normally closed

contacts.

Manual ResetFor Manual resetting a pushbutton must be connected

to terminals Y 1 and Y 3. This Reset is monitored.

Automatic ResetFor Automatic resetting, Y 1 - Y 2 must be linked.

Internal Circuitry UE 23-2 MF

A1 A2

14 24 32

K1

K2

Y1 Y2 Y3 13 23 31

CONTROL

LOGIC

RESET

Page 17: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 178 009 607/18-09-03

UE 23-2 MF Series

1) The wires for the input and output signals shall be routed outside the control cabinet according to the safety category to be used

Technical Data UE 23-2 MF

min. typ. max.General System Data

Protection Class 2 according to EN 50 178 between supply circuit / control circuit / output circuits

and between the output circuits mutually

Safety Category: EN 954-1 4 1)

Stop Category: EN 60 204 0

Supply voltage/Input circuit VS (A 1 - A 2)UE 23-2 MF 2 D2 20.4 V DC 24 V DC 26.4 V DCUE 23-2 MF 2 A4 98 V AC 115/120 V AC 132 V ACUE 23-2 MF 2 A3 196 V AC 230 V AC 253 V AC

Power consumptionAC 2.7 VADC 1.6 W

Residual ripple in DC mode(within the limits of V

S) 2.4 V

PP

Nominal frequency in AC mode 50 Hz 60 Hz

Control voltage (Y 1 - Y 2 - Y 3)Control voltage 40 V DC

Control current 200 mA

Fuse PTC resistor

Reset timeManual (Y 3) 70 msAutomatic (Y 2) 600 ms

Galvanic separation (only on AC units) yes

Output circuits (13 - 14, 23 - 24, 31 - 32)Response time (K 1 / K 2) 30 ms 80 ms

Relay contacts 2 Normally open contacts (NO), safety relevant1 Normally closed contact (NC), not safety relevant

Contact type positively guided

Contact material Silver alloy; gold-plated

Load capacity of the contactsSwitching voltage 10 V AC/DC 230 V AC / 30 V DCSwitching current 10 mA 6 ATotal current across all contacts 12 A

Category to EN 60 947-5-1 AC-15 Ue 230 V AC, Ie 4 A (360 c/h)

AC-15 Ue 230 V AC, Ie 3 A (3600 c/h)

DC-13 Ue 24 V DC, Ie 4 A (360 c/h)

DC-13 Ue 24 V DC, Ie 2,5 A (3600 c/h)

Permitted switching frequency 3600 c/h

Service life, mechanical (switching cycles) 1 x 107

Service life, electrical (dependent upon loading) 2 x 106

Operating data see Page 47

Weight 270 g

Page 18: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

18 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03

Order reference list for UE 23-2 MF

Type Outputs Connections Electrical supply Part No.

Screw type terminals 24 V DC 115 - 120 V AC 230 V AC

UE 23- 2 MF 2 D3 6 026 146

UE 23- 2 MF 2 A4 6 026 147

UE 23- 2 MF 2 A3 6 026 148

UE 23-2 MF Series

Page 19: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 198 009 607/18-09-03

UE 42-2 HD Series

UE 42-2 HDSafety Relayfor two-hand operationAutomatic Start

EDM

EDM

19

EN 954-1 Category 4

EN 574 Type III C

2

1

USC

USC

Application

The UE 42-2 HD safety relay serves as a monitoring

module for:

� Two-hand controls with Type III C requirements to

EN 574 and to EN 954-1, Category 4

� Two-hand pushbuttons, each with 1 normally open /1 normally closed contact combinations

� Safety Switches (EN 1088)

Features

� Dual-channel control

� Outputs: 2 normally open contacts, 1 normallyclosed contact

� 3 LEDs for supply voltage, relay K 1 and relayK 2

� Automatic Start

� Increase in the number of outputs by way of the

expansion unit UE 10-4 XT

� External device monitoring (EDM)

� Available with removable terminals (key coded)

� “A” Housing (see Page 4), width: 22.5 mm

See Page 54 for sample wiring diagrams

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice8 009 607/18-09-03

Page 20: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

20 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03

UE 42-2 HD Series

Function

The UE 42-2 HD unit corresponds to EN 574 Type III C.

A prerequisite for the release of the outputs is that the

two inputs (e. g. two-hand pushbuttons) are actuated

within 0.5 sec.

After applying the supply voltage to the terminals A 1 -

A 2 the LED SUPPLY illuminates to indicate that

electrical power is present. Pressing the two-hand

pushbuttons S 1 and S 2 at the same time (see Page

53 – Sample wiring diagrams) closes the two normally

open contacts. Releasing even one of the buttons will

cause the circuits to adopt the open circuit status.

A renewed attempt to initiate starting is only possible if

both Start buttons are set to their nominal start position

(for two-hand pushbuttons units: if both have been

released) and the normally closed contact is closed.

External device monitoring (EDM)The UE 42-2 HD can take over the function of external

device monitoring. The normally closed contacts of the

external relays are switched in series, connected to the

terminals Y 1 - Y 2.

Automatic startThe UE 42-2 HD has an Automatic start facility.

Monitoring of simultaneous activationThe pressing of the Start buttons at the same time is

monitored. Only when both Start buttons are activated

within 0.5 sec do normally open contacts close and the

normally closed contact opens.

The UE 42-2 HD 2 unit has screw type terminals.

The UE 42-2 HD 3 unit has removable terminals.

Internal Circuitry UE 42-2 HD

A1 A2 Y1 Y2 Y11 Y12 Y14 13 23 31

Y21 Y22 Y24 14 24 32

K1

K2

Feedback

Channel 2

Channel 1

Control-Logic

Page 21: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 218 009 607/18-09-03

UE 42-2 HD Series

Technical Data UE 42-2 HD

min. typ. max.

General System Data

Supply voltage to A 1 / A 2Electrical output circuit > 25 V AC / 60 V DC PELVElectrical output circuit < 25 V AC / 60 V DC PELV or SELV

Safety Category: EN 954-1 4

Supply voltage VS

(A 1 / A 2) 20.4 V AC/DC 24 V AC/DC 26.4 V AC/DC

Power consumptionAC 2.7 VADC 1.5 W

Residual ripple in DC mode(within the limits of V

S) 2.4 V

PP

Nominal frequency in AC mode 50 Hz 60 Hz

Control voltage (Y 11 - Y 21)

Control voltage 24 V DC

Control current 60 mA

Short-circuit current between Y 11 and A 2 1000 mA

Fuse PTC resistor

Galvanic separation between A 1 / A 2 and Y 11 / Y 21 no

Input circuits (Y 12 - Y 14 and Y 22 - Y 23)

Input current 60 mA

Reset time 40 ms

Activation time tolerance between the two Start buttons 500 ms

Minimum switch-off time 250 ms

Line resistance at the input circuit < 70 Ohm

Switch-on time (upon applying the supply voltage) 250 ms

Output circuits (13 - 14, 23 - 24, 31 - 32)

Response time (K 1 / K 2) 50 ms

Relay contacts 2 Normally open contacts (NO), safety relevant

1 Normally closed contact (NC), not safety relevant

Contact type positively guided

Contact material Silver alloy; gold-plated

Load capacity of contactsSwitching voltage 10 V AC/DC 230 V AC / 30 V DC

Switching current 10 mA 6 ATotal current across all contacts 12 A

Application Category to EN 60 947-5-1 AC-15 Ue 230 V AC, Ie 4 A (360 c/h)

AC-15 Ue 230 V AC, Ie 3 A (3600 c/h)

DC-13 Ue 24 V DC, Ie 4 A (360 c/h)

DC-13 Ue 24 V DC, Ie 2.5 A (3600 c/h)

Permitted switching frequency 3600 c/h

Service life, mechanical (switching cycles) 1 x 107

Service life, electrical (dependent upon loading) 2 x 106

Operating data see Page 47

Weight 0.2 kg

Page 22: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

22 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03

Order reference list for UE 42-2 HD

Type Outputs Connections Electrical supply Part No.

Screw type terminals Removable terminals 24 V AC/DC

UE 42- 2 HD 2 D2 6 024 878

UE 42- 2 HD 3 D2 6 024 881

UE 42-2 HD Series

Page 23: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 238 009 607/18-09-03

UE 43-2 MFSafety RelayManual or Automatic Reset

EDM

EDM

UE 43-2 MF Series

23

EN 954-1 Category 4

2

1

oder

USC

Application

The UE 43-2 MF Safety Relay serves as a monitoring module for:

� Emergency Stops (to EN 418): for single- or dual-channel system

use

� Safety Switches (to EN 1088): for single- or dual-channel system

use, e. g. movable guards

� Control systems to EN 954-1 (Category 4)

Features

� Single- or dual-channel control

� Cross circuit detection

� Outputs: 2 normally open contacts, 1 normally closed contacts

� 3 LEDs: for supply voltage, relays K 1 and K 2

� Manual Reset

� Automatic Reset

� Increase in the number of outputs by way of the expansion units

UE 10-4 XT, UE 11-4 DX

� External device monitoring (EDM)

� Available with removable terminals (key coded)

� “A” Housing (see Page 4), width: 22.5 mm

See Page 55 for sample wiring diagram

USC

or

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice8 009 607/18-09-03

Page 24: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

24 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03

Function

After applying the supply voltage (LED SUPPLY illumi-

nates), the normally open contacts remain in the opened

state. If the connected sensor is not activated (i.e. the

input circuits are closed), then the normally open

contacts close immediately in Automatic Reset (LED

„K 1, K 2“ illuminate). In the case of Manual Reset, this

only occurs after pressing and releasing the Reset

button. Activation of the sensor (opening of one or both

input circuits) effects the opening of the normally open

outputs.

External device monitoring (EDM)The UE 43-2 MF unit can take over the function of

external device monitoring. The contactor monitoring

system monitors the external relays by means of their

normally closed contacts.

Manual ResetFor Manual resetting a pushbutton must be connected to

terminals S 33 - S 34. Reset is monitored.

Automatic ResetFor Automatic resetting, S 12 - S 35 must be linked.

Cross circuit detectionCross circuit is detected on dual-channel wired systems if

these are wired with opposing polarity.

Monitoring of synchronisationOnly if input 2 closes by no later than 0.5 sec after input

1 do the ouput circuits close. If input 2 closes before

input 1, the monitoring of synchronisation will not be

effected, and the output circuits will close. This

monitoring only takes place in Automatic Reset.

The UE 43-2 MF 2 units have screw type terminals.

The UE 43-2 MF 3 units have removable terminals.

UE 43-2 MF Series

Internal Circuitry UE 43-2 MF

-- +

K2--

+ +

K1

+ +A1 A2

S21 S11 S33 S22 14 24 32

K1

K2Control- Logic

S34 S35 S12 S31 13 23 31

Page 25: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 258 009 607/18-09-03

UE 43-2 MF Series

Technical Data UE 43-2 MF

min. typ. max.

General System Data

Supply voltage to A 1 / A 2Electrical output circuit > 25 V AC / 60 V DC PELVElectrical output circuit < 25 V AC / 60 V DC PELV or SELV

Safety Category: EN 954-1 4

Stop Category: EN 60 204 0

Supply voltage VS (A 1 / A 2) 20.4 V AC/DC 24 V AC/DC 26.4 V AC/DC

Power consumptionA C 4.6 VAD C 2.1 W

Residual ripple in DC mode(within the limits of V

S) 2.4 V

PP

Nominal frequency in AC mode 50 Hz 60 Hz

Control voltage S 33 / S 11 und S 21

Control voltage 17.4 V DC 22 V DC

Control current 40 mA 100 mA

Short-circuit current between S 33 / S 11 and S 21 2000 mA

Fuse PTC resistor

Reaction time by cross connection 3 s

Activation time upon detection of cross connection 3 s

Galvanic separation between A 1 / A 2 and S 21, S 11, S 33 n o

Input circuits (S 12, S 31, S 22, S 34, S 35)

Input current S 12 und S 31 / S 22 40 mA 100 mA

Input current S 34 / S 35 5 mA 50 mA

Reset time

Manual (S 34) 40 msAutomatic (S 35) 200 ms 500 ms

Activation time of Reset button 50 ms

Line resistance at the input circuit 35 Ohm

Synchronisation time 500 ms

Output circuits (13 - 14, 23 - 24, 31 - 32)

Response time (K 1 / K 2) 25 ms

Minimum time outputs will stay off 40 ms

Relay contacts 2 Normally open contacts (NO), safety relevant

1 Normally closed contact (NC), not safety relevant

Contact type positively guided

Contact material Silver alloy; gold-plated

Load capacity of contactsSwitching voltage 10 V AC/DC 230 V AC / 30 V DC

Switching current 10 mA 6 ATotal current across all contacts 12 A

Application Category to EN 60 947-5-1

AC-15 Ue 230 V AC, Ie 4 A (360 c/h)

AC-15 Ue 230 V AC, Ie 3 A (3600 c/h)

DC-13 Ue 24 V DC, Ie 4 A (360 c/h)

DC-13 Ue 24 V DC, Ie 2.5 A (3600 c/h)

Permitted switching frequency 3600 c/h

Service life, mechanical (switching cycles) 1 x 107

Service life, electrical (dependent upon loading) 1 x 105

Operating data see Page 47

Weight 0.2 kg

Page 26: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

26 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03

Order reference list for UE 43- 2 MF

Type Outputs Connections Electrical supply Part No.

Screw type terminals Removable terminals 24 V AC/DC

UE 43- 2 MF 2 D2 6 024 893

UE 43- 2 MF 3 D2 6 024 894

UE 43-2 MF Series

Page 27: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 278 009 607/18-09-03

UE 43-3 MF Series

UE 43-3 MFSafety RelayManual or Automatic Reset

??

EDM

EDM

27

EN 954-1 Category 4

3

1

USC

oder

Application

The UE 43-3 MF Safety Relay serves as a monitoring module for:

� Emergency Stops (to EN 418): for single- or dual-channel system

use

� Safety Switches (to EN 1088): for single- or dual-channel system

use, e. g. on movable guards

� Control systems to EN 954-1 (Category 4)

Features

� Single- or dual-channel control

� Cross circuit detection

� Outputs: 3 normally open contacts, 1 normally closed contact

� 3 LEDs: for supply voltage, relays K 2 and K 3

� Manual Reset

� Automatic Reset

� Increase in the number of outputs by way of the expansion units

UE 10-4 XT, UE 11-4 DX

� External device monitoring (EDM)

� “B” Housing (see Page 5), width: 45 mm

See Pages 56 and 57 for sample wiring diagrams

USC

or

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice8 009 607/18-09-03

Page 28: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

28 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03

+

+

--

+ + ++

--

Y13 Y14 Y12 Y12 Y31 13 23 33 41A1 A2

K1 K2 K3

Y11 Y21 Y22 14 24 34 42 42

K2

K3

Internal Circuitry UE 43-3 MF

Function

After applying the supply voltage (LED SUPPLY illumi-

nates) the normally open contacts remain open. If the

connected sensor is not activated (i. e. the input circuits

are closed), the normally open contacts close imme-

diately in Automatic Reset (LED K 2 and K 3 illuminate).

In the case of Manual resetting, this is only effected

upon pressing and releasing the Reset button.

Activation of the sensor (opening of one or both input

circuits) effects the opening of the normally open

contacts (LED K 2 and K 3 off).

External device monitoring (EDM)The UE 43-3 MF unit can take over the external device

monitoring. The contactor monitoring system monitors

the external relays by way of their normally closed

contacts.

Manual ResetFor Manual resetting a pushbutton must be connected

to terminals Y 12 and Y 13. Reset is monitored.

Automatic ResetFor Automatic resetting Y 12 - Y 14 must be linked.

Cross circuit detectionCross circuit is detected on dual-channel wired systems,

if these are wired with opposing polarity.

Monitoring of synchronisationOnly if input 2 closes by no later than 0.5 sec after

input 1 do the ouput circuits close. If input 2 closes

before input 1, the monitoring of synchronisation will

not be effected, and the output circuits will close. This

monitoring only takes place in Automatic Reset.

UE 43-3 MF Series

Page 29: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 298 009 607/18-09-03

UE 43-3 MF Series

Technical Data UE 43-3 MF

min. typ. max.General System Data

Supply voltage to A 1 / A 2 for DC UnitsElectrical output circuit > 25 V AC / 60 V DC PELVElectrical output circuit < 25 V AC / 60 V DC PELV or SELV

Voltage supply to A 1 / A 2 on AC units Use of earth conductor terminal

Safety Category: EN 954-1 4

Stop Category: EN 60 204 0

Supply voltage VS

UE 43-3 MF 2 D3 20.4 V DC 24 V DC 26.4 V DCUE 43-3 MF 2 A0 20.4 V AC 24 V AC 26.4 V ACUE 43-3 MF 2 A1 97.75 V AC 115 V AC 126.5 V ACUE 43-3 MF 2 A2 102.0 V AC 120 V AC 132.0 V ACUE 43-3 MF 2 A3 195.5 V AC 230 V AC 253.0 V AC

Power consumptionAC 2.5 W / 3.2 VADC 1.0 W

Residual ripple in DC mode(within the limits of V

S) 2.4 V

PP

Nominal frequency in AC mode 50 Hz 60 Hz

Control voltage Y 11 and Y 21Control voltage 24 V DC

Control current 40 mA

Short circuit current between Y 11 and A 2 1000 mA

FuseAC units short circuit resistant transformerDC units PTC resistor

Reaction time by cross connection 3 s

Galvanic separation between A 1 / A 2 and Y 11 - Y 21 - PE only on AC units

Input circuits (Y 12 and Y 31 - Y 22)Input current at Y 12 and Y 31 15 mA

Input current at Y 13 and Y 14 (reset circuit) 40 mA

Reset timeManual (Y 13) 150 ms 250 msAutomatic (Y 14) 0.8 s 1.2 s

Synchronisation time 500 ms

Line resistance at the input circuit < 70 Ohm

Input time upon applying supply voltage 100 ms

Output circuits (13 - 14, 23 - 24, 33 - 34, 41 - 42)Response time (K 2 / K 3) 50 ms

Relay contacts 3 Normally open contacts (NO), safety relevant1 Normally closed contact (NC), not safety relevant

Contact type positively guided

Contact material Silver alloy; gold-plated

Load capacity of contactsSwitching voltage 10 V AC/DC 230 V AC / 30 V DCSwitching current 10 mA 6 ATotal current across all contacts 18 A

Application Category to EN 60 947-5-1 AC-15 Ue 230 V AC, Ie 6 A (3600 c/h)

DC-13 Ue 24 V DC, Ie 6 A (360 c/h)

DC-13 Ue 24 V DC, Ie 3 A (3600 c/h)

Permitted switching frequency 3600 c/h

Service life, mechanical (switching cycles) 1 x 107

Service life, electrical (dependent upon loading) 2 x 106

Operating data see Page 47

WeightAC unit 0.36 kgDC unit 0.30 kg

Page 30: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

30 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03

Order reference list for UE 43-3 MF

Type Outputs Connections Electrical supply Part No.

Screw type terminals 24 V DC 24 V AC 115 V AC 120 V AC 230 V AC

UE 43- 3 MF 2 D3 6 024 897

UE 43- 3 MF 2 A0 6 024 898

UE 43- 3 MF 2 A1 6 024 899

UE 43- 3 MF 2 A2 6 024 900

UE 43- 3 MF 2 A3 6 024 901

UE 43-3 MF Series

Page 31: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 318 009 607/18-09-03

UE 43-6 MFSafety RelayManual or Automatic Reset

??

oder

31

EDM

EDM

6

4

EN 954-1 Category 4

UE 43-6 MF Series

Available as of 2004

USC

or

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice8 009 607/18-09-03

Application

The UE 43-6 MF Safety Relay serves as a monitoring

module for:

� Emergency Stops (to EN 418): for single- or dual-

channel system use

� Safety Switches (to EN 1088): for single- or dual-

channel system use, e. g. on movable guards

� Control systems to EN 954-1 (Category 4)

Features

� Single- or dual-channel control

� Cross circuit detection

� Outputs: 6 normally open contacts, 4 normally closed

contacts

� 6 LEDs: for supply voltage, CH 1, CH 2, relays K 1,

K 2 and “K 3 RESET“

� Manual Reset

� Automatic Reset

� Increase in the number of outputs by way of the

expansion units UE 10-4 XT, UE 11-4 DX

� External device monitoring (EDM)

� “C” Housing (see Page 5), width: 90 mm

See Page 58 for sample wiring diagram

Page 32: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

32 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03

Internal Circuitry UE 43-6 MF

UE 43-6 MF Series

Function

After applying the supply voltage (LED SUPPLY illumi-

nates), the normally open contacts remain open. If the

connected sensor is not activated, the LEDs CH 1 and

CH 2 illuminate. In the case of Automatic resetting, the

normally open contacts close immediately (LED K 1 and

K 2 illuminate). With Manual resetting the normally open

contacts only close upon pressing and releasing the

Reset button.

The activation of the sensor (opening of one or both

input circuits) effects the opening of the normally open

contacts (LED K 1 and K 2 off).

External device monitoring (EDM)The UE 43-6 MF unit can take over the external device

monitoring. The contactor monitoring system monitors

the external relays by way of their normally closed

contacts.

Manual ResetFor Manual Reset a pushbutton is to be connected to

the terminals S 33 - S 34 and a link connected

between S 12 and Y 3 and between Y 1 and S 37.

This Reset is monitored.

Automatic ResetFor Automatic Reset S 12 - S 34 and Y 3 - S 33 must

be linked.

Cross circuit detectionCross circuit is detected on dual-channel wired systems,

if these are wired with opposing polarity.

Monitoring of synchronisationOnly if input 2 closes by no later than 0.5 sec after

input 1 do the ouput circuits close. If input 2 closes

before input 1, the monitoring of synchronisation will

not be effected, and the output circuits will close. This

monitoring only takes place in Automatic Reset.

14

13

24

23

34

33

44

43

54

53

64

63

72

71

82

81

92

91

02

01

EDM

RESET

CONTROL- LOGIC

K 1

K 2

A1 A2 S34 Y1 S37 S12S11

+

S21Y2Y1 S22 Y3

CH 2

CH 1

S33

– +

Page 33: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 338 009 607/18-09-03

UE 43-6 MF Series

Technical Data UE 43-6 MF (provisional)

min. typ. max.

General System Data

Supply voltage to A 1 / A 2 for DC unitsElectrical output circuit > 25 V AC / 60 V DC PELVElectrical output circuit < 25 V AC / 60 V DC PELV or SELV

Voltage supply to A 1 / A 2 for AC unit Use earth conductor terminal

Safety Category: EN 954-1 4

Stop Category: EN 60 204 0

Supply voltage VS (A 1 / A 2)

UE 43-6 MF 2 D 3 20.4 V DC 24 V DC 26.4 V DCUE 43-6 MF 2 A 2 102.0 V AC 120 V AC 132.0 V ACUE 43-6 MF 2 A 3 195.5 V AC 230 V AC 253.0 V AC

Power consumptionAC 4.2 W / 4.5 VADC 2.4 W

Residual ripple in DC mode(within the limits of V

S) 2.4 V

PP

Nominal frequency in AC mode 50 Hz 60 Hz

Control voltage S 11 and S 21

Control voltage 24 V DC

Control current 40 mA

Short circuit current (between Y 11 and A 2) 1000 mA

FuseAC units short circuit resistant transformerDC units PTC resistor

Reaction time by cross connection (DC unit) 3 s

Galvanic separationbetween A 1 - 2 and Y 11 - Y 21 - PE only on AC units

Input circuits (S 12 - S 22 and Y 3 - S 22)

Input current 40 mA

Reset timeManual 350 msAutomatic 500 ms

Synchronisation time 500 ms

Line resistance at the input circuit 85 Ohm

Switch-on time upon applying the supply voltage (AC units) 100 ms

Output circuits(13 - 14, 23 - 24, 33 - 34, 43 - 44, 53 - 54, 63 - 64, 71 - 72, 81 - 82, 91 - 92, 01 - 02)

Response time (K 1 / K 2) 60 ms

Relay contacts 6 Normally open contacts (NO), safety relevant4 Normally closed contacts (NC), not safety relevant

Contact type positively guided

Contact material Silver alloy; gold-plated

Load capacity of contactsSwitching voltage 10 V AC/DC 230 V AC / 30 V DCSwitching current 10 mA 6 ATotal current across all contacts 24 A

Application Category to EN 60 947-5-1 AC-15 Ue 230 V AC, Ie 3 A (3600 c/h)

DC-13 Ue 24 V DC, Ie 2 A (3600 c/h)

Permitted switching frequency 3600 c/h

Service life, mechanical (switching cycles) 1 × 107

Service life, electrical (dependent upon loading) 2 × 106

Operating data see Page 47

Weight 0.8 kg

Page 34: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

34 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03

UE 43-6 MF Series

Order reference list for UE 43-6 MF

Type Outputs Connections Electrical supply Part No.

Screw type terminals 24 V DC 120 V AC 230 V AC

UE 43- 6 MF 2 D3 6 024 902

UE 43- 6 MF 2 A2 6 024 905

UE 43- 6 MF 2 A3 6 024 906

Page 35: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 358 009 607/18-09-03

UE 44-3 SL Series

Application

The UE 44-3 SL Safety Relay serves as a monitoring

module for:

� Emergency Stops (to EN 418): for single- or dual-

channel system use

� Safety Switches (to EN 1088): for single- or dual-

channel system use, e. g. on movable guards

� Safety Switches with mechanical locking (e. g. i200)

� Control systems to EN 954-1 (Category 4)

Features

� Single- or dual-channel control

� Cross circuit detection

� Outputs: 2 normally open contacts, 1 normally open

contact with on-delay, adjustable from 0.15 … 3 sec or

1.5 … 30 sec

� 3 LEDs: for supply voltage, relays K 1 / K 2 (without

delay) and relays K 3 / K 4 (on-delayed)

� Manual Reset

� Automatic Reset

� Increase in the number of outputs by way of the

expansion units UE 10-4 XT, UE 11-4 DX

� External device monitoring (EDM)

� Available with removable terminals (key coded)

� “A” Housing (see Page 4), width: 22.5 mm

UE 44-3 SLSafety Relaywith additional on-delay

EDM

EDM

35

EN 954-1 Category 4

+

2

1

USC

oder

USC

or

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice8 009 607/18-09-03

See Page 59 for sample wiring diagram

i200

Page 36: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

36 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03

Function

After applying the supply voltage (LED SUPPLY illumi-

nates), the normally open contacts (13 - 14 / 23 - 24)

remain open. After completion of the on-delay set on

the relay, the delay circuit (37 - 38) closes, and the

LED K 3 / K 4 illuminates. If the connected sensor is

not activated (i. e. the input circuits are closed), the

normally open contacts (13 - 14 / 23 - 24) close

immediately during Automatic Reset, the LED K 1 / K 2

illuminates, and the delay circuit (37 - 38) opens (LED

K 3 / K 4 off). In the case of Manual Reset, this only

occurs after pressing and releasing the Reset button.

The activation of the sensor (opening of one or both

input circuits) effects the opening of both normally open

contacts (13 - 14 / 23 - 24), with LEDs K 1 / K 2 being

off, and a time delayed closing of the third circuit (37 -

38), with LED K 3 / K 4 illuminating.

External device monitoring (EDM)The unit can take over external device monitoring. The

contactor monitoring system monitors the external

relays by way of their normally closed contacts.

Manual ResetFor Manual resetting, a pushbutton is to be connected

between 24 V DC supply and terminal S 34. This Reset

is monitored. For applications with mechanical locking

safety switches, only channel 2 must be closed during

Manual Reset (see page 59)

Automatic ResetFor Automatic resetting S 12 - S 35 must be linked. For

applications with mechanical locking safety switches,

only channel 1 must be closed during Automatic Reset.

Cross circuit detectionCross circuit is detected on dual-channel wired systems,

if these are wired with opposing polarity.

Monitoring of synchronisationOnly if input 2 closes by no later than 0.5 sec after

input 1 do the ouput circuits close. If input 2 closes

before input 1, the monitoring of synchronisation will not

be effected, and the output circuits will close. This

monitoring only takes place in Automatic Reset.

The UE 44-3 SL 2 unit has screw type terminals.

The UE 44-3 SL 3 unit has removable terminals.

Internal Circuitry UE 44-3 SL

UE 44-3 SL Series

Channel 1 Channel 2

RESET

CONTROL-LOGICK2

K4

K1

K3

+

S31 S22S12S21-

S11+

A1 A2 13 23

14 24

37

38

S33 S34 S35

(-)(+)

Page 37: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 378 009 607/18-09-03

UE 44-3 SL Series

Technical Data UE 44-3 SL

min. typ. max.General System Data

Supply voltage to A 1 / A 2 for DC units

Electrical output circuit > 25 V AC / 60 V DC PELVElectrical output circuit < 25 V AC / 60 V DC PELV or SELV

Safety Category: EN 954-1 4

Stop Category: EN 60 204 0

Supply voltage VS

20.4 V DC 24 V DC 26.4 V DC

Power consumption 1.8 W

Residual ripple in DC mode(within the limits of V

S) 2.4 V

PP

Control voltage S 11 - S 33 und S 21Control voltage 22 V DC

Control current 60 mA

Electrical short circuit between S 11 and A 2 2200 mA

Fuse PTC resistor

Reaction time by cross connection 2 s

Galvanic separationbetween A 1 / A 2 and S 11 - S 21 no

Input circuits (S 12 and S 31)Input current at S 12 and S 31 25 mA 100 mA

Input current at S 34 / S 35 (reset circuit) 40 mA 50 mA

Reset timeManual (S 34) 30 msAutomatic (S 35) 750 ms

Synchronisation time 500 ms

Activation time of Reset button 250 ms

Line resistance at the input circuit < 85 Ohm

Output circuits (13 - 14, 23 - 24, 37 - 38)Response time (K 1 / K 2) 25 ms

On-Delay time (K 3 / K 4)UE 44-3 SL xD3 3 0.15 s 3 sUE 44-3 SL xD3 30 1.5 s 30 s

Relay contacts 2 Normally open contacts (NO), Safety Cat. 41 Normally open contact (NO), on-delayed, Safety Cat. 3

Contact type positively guided

Contact material Silver alloy; gold-plated

Load capacity of contactsSwitching voltage 10 V AC/DC 230 V AC / 30 V DCSwitching current 10 mA 6 ATotal current across all contacts 12 A

Application Category to EN 60 947-5-1 AC-15 Ue 230 V AC, Ie 4 A (3600 c/h)

DC-13 Ue 24 V DC, Ie 5 A (360 c/h)

DC-13 Ue 24 V DC, Ie 3 A (3600 c/h)

Permitted switching frequency 3600 c/h

Service life, mechanical (switching cycles) 5 x 106

Service life, electrical (dependent upon loading) 2 x 106

Operating data see Page 47

Weight 0.2 kg

Page 38: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

38 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03

UE 44-3 SL Series

Order reference list for UE 44-3 SL

Type Outputs Connections Electrical supply Delay in sec. Part No.

Screw type terminals Removable terminals 24 V DC

UE 44- 3 SL 2 D3 3 6 024 907

UE 44- 3 SL 3 D3 3 6 024 908

UE 44- 3 SL 2 D3 30 6 024 909

UE 44- 3 SL 3 D3 30 6 024 910

Page 39: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 398 009 607/18-09-03

UE 45-3 S1 Series

UE 45-3 S1Safety Relaywith additional off-delay

Application

The UE 45-3 S1 serves as a monitoring module for:

� Emergency Stops (to EN 418): for single- or dual-

channel system use

� Safety Switches (to EN 1088): for single- or dual-

channel system use, e. g. on movable guards

� Control systems to EN 954-1 (Category 4)

Features

� Single- or dual-channel control

� Cross circuit detection

� Outputs: 2 normally open contacts, 1 normally open

contact with off-delay, adjustable from 0.15 … 3 sec

or 1.5 … 30 sec

� 3 LEDs: for supply voltage, relays K 1 / K 2

(without delay) and relays K 3 / K 4 (off-delayed)

� Manual Reset

� Automatic Reset

� Increase in the number of outputs by way of the

expansion units UE 10-4 XT, UE 11-4 DX

� External device monitoring (EDM)

� Available with removable terminals (key coded)

� “A” Housing (see Page 4), width: 22.5 mmEDM

EDM

39

oder

EN 954-1 Category 4

EN 60 204-1 Stop Category 0/1

+

2

1

USC

See Page 60 for sample wiring diagram

USC

or

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice8 009 607/18-09-03

Page 40: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

40 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03

Function

After applying the supply voltage (LED SUPPLY illumi-

nates), the normally open contacts remain open. If the

connected sensor is not activated (i. e. the input circuits

are closed), the normally open contacts close imme-

diately during Automatic resetting, LED K 1 / K 2 and

K 3 / K 4 illuminate. In the case of Manual resetting,

this only occurs after pressing and releasing the Reset

button.

The activation of the sensor (opening of one or both

input circuits) effects the opening of both normally open

contacts (13 - 14 / 23 - 24) immediately, and a time

delayed closing of the third circuit (37 - 38), with LED

K 1 / K 2 immeditely going off and K 3 / K 4 going off

later.

External device monitoring (EDM)The unit can take over external device monitoring. The

contactor monitoring system monitors the external

relays by way of their normally closed contacts.

Manual ResetFor Manual resetting, a pushbutton must be connected

to terminals S 33 - S 34. This Reset is monitored.

Automatic ResetFor Automatic resetting S 33 - S 35 must be linked.

Cross circuit detectionCross circuit is detected on dual-channel wired systems,

if these are wired with opposing polarity.

Monitoring of synchronisationOnly if input 2 closes by no later than 0.5 sec after

input 1 do the ouput circuits close. If input 2 closes

before input 1, the monitoring of synchronisation will

not be effected, and the output circuits will close. This

monitoring only takes place in Automatic Reset.

The UE 45-3 S1 2 unit has screw type terminals.

The UE 45-3 S1 3 unit has removable terminals.

Channel 1 Channel 2

RESET

CONTROL- LOGICK 2

K 4

K 1

K 3

+

S31 S22S12S21

-S11

+

A1 A2 13 23

14 24

37

38

S33 S34 S35

(–)(+)

Internal Circuitry UE 45-3 S1

UE 45-3 S1 Series

Page 41: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 418 009 607/18-09-03

UE 45-3 S1 Series

Technical Data UE 45-3 S1

min. typ. max.General System Data

Supply voltage to A 1 / A 2

Electrical output circuit > 25 V AC / 60 V DC PELVElectrical output circuit < 25 V AC / 60 V DC PELV or SELV

Safety Category: EN 954-1 4

Stop Category: EN 60 204 0/1

Supply voltage VS

20.4 V DC 24 V DC 26.4 V DC

Power consumption 2.6 W

Residual ripple in DC mode(within the limits of V

S) 2.4 V

PP

Control voltage S 11 / S 33 and S 21Control voltage 24 V DC

Control current 60 mA

Electrical short circuit between S 11 and A 2 2200 mA

Fuse PTC resistor

Reaction time by cross connection 2 s

Galvanic separationbetween A 1 / A 2 and S 11 / S 21 no

Input circuits (S 12 and S 31)Input current at S 12 and S 31 25 mA 100 mA

Input current at S 34 / S 35 (reset circuit) 40 mA 50 mA

Reset timeManual (S 34) 30 msAutomatic (S 35) 600 ms

Synchronisation time 500 ms

Activation time for Reset button 200 ms

Line resistance at the input circuit < 85 Ohm

Output circuits (13 - 14, 23 - 24, 37 - 38)Response time (K 1 / K 2) 25 ms

Off-delay time (K 3 / K 4)

UE 45-3 S1 xD3 3 0.15 s 3 sUE 45-3 S1 xD3 30 1.5 s 30 s

Relay contacts 2 Normally open contacts (NO), Safety Cat. 41 Normally open contact (NO), off-delayed, Safety Cat. 3

Contact type positively guided

Contact material Silver alloy; gold-plated

Load capacity of contactsSwitching voltage 10 V AC/DC 230 V AC / 30 V DCSwitching current 10 mA 6 ATotal current across all contacts 12 A

Application Category to EN 60 947-5-1 AC-15 Ue 230 V AC, Ie 4 A (3600 c/h)

DC-13 Ue 24 V DC, Ie 5 A (360 c/h)

DC-13 Ue 24 V DC, Ie 3 A (3600 c/h)

Permitted switching frequency 3600 c/h

Service life, mechanical (switching cycles) 5 x 106

Service life, electrical (dependent upon loading) 2 x 106

Operating data see Page 47

Weight 0.2 kg

Page 42: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

42 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03

UE 45-3 S1 Series

Order reference list for UE 45-3 S1

Type Outputs Connections Electrical supply Delay in sec. Part No.

Screw type terminals Removable terminals 24 V DC

UE 45- 3 S1 2 D3 3 6 024 911

UE 45- 3 S1 3 D3 3 6 024 912

UE 45- 3 S1 2 D3 30 6 024 913

UE 45- 3 S1 3 D3 30 6 024 914

Page 43: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 438 009 607/18-09-03

UE 48-2 OS and UE 48-3 OS Series

UE 48-2 OS and UE 48-3 OSSafety RelayAutomatic or Manual Reset

Application

The UE 48 Safety Relays serve as a monitoring module for:

� Emergency Stops (to EN 418): for single- or dual-channel system use

� Safety Switches (to EN 1088): for single- or dual-channel system use, e. g.

on movable guards

� Safety Mats in accordance with DIN EN 1760 using 4-wire technology

� Electro-sensitive protective equipment (ESPE) employing monitored

semiconductor outputs (OSSD), such as FGS, PLS, C 2000, M 2000,

C 4000, S 3000, LSI, MSL

� Control systems to EN 954-1 (Category 4)

Features

� Single- or dual-channel control

� Cross circuit detection

� Outputs

UE 48-2 OS: 2 normally open contacts, 1 normally closed contact

UE 48-3 OS: 3 normally open contacts

� 3 LEDs: for supply voltage, relays K 1 and K 2

� Manual or Automatic Reset

� Increase in the number of outputs by way of the expansion units

UE 10-4 XT, UE 11-4 DX

� External device monitoring (EDM)

� Available with removable terminals (key coded)

� “A” Housing (See Page 4), width: 22.5 mm

EDM

EN 954-1 Category 4

EN 61 496 Types 2, 3, 4

EDM

43

3

2

1UE 48-2 OS

UE 48-3 OS

UE 48-3 OS availableas of 2004

See Pages 61 and 62 for sample wiring diagrams

USC

USC

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice8 009 607/18-09-03

OS

SD

1O

SSD

2OS

SD

1

OS

SD

2

oder

oder

oder

odero r

or

or

or

Page 44: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

44 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03

Function

After applying the supply voltage (LED SUPPLY illumi-

nates), the normally open contacts remain open. If the

connected sensor is not activated or the protective field

of the connected electro-sensitive protective equipment

(ESPE) is not broken (i. e. the input circuits are closed),

then the normally open contacts close immediately in

Automatic Reset, LED K 1 and K 2 illuminate. In the

case of Manual resetting, this only occurs after pressing

and releasing the Reset button.

The activation of the sensor or incursion into the

protective field of the non-contact safety device (open

state of one of the two input circuits) effects the

opening of the normally open contacts (LED K 1 and

K 2 off).

External device monitoring (EDM)The unit can take over external device monitoring. The

contactor monitoring system monitors the external

relays by way of their normally closed contacts.

Manual ResetFor Manual resetting, a pushbutton must be connected

to terminals S 33 - S 34. This Reset is monitored.

Automatic ResetFor ESPE’s: S 33 - S 35 must be linked;

for applications with potential free contacts on the input

circuit S 12 - S 35 must be linked.

Cross circuit detectionCross circuit is detected on dual-channel wired systems,

if these are wired with opposing polarity.

The UE 48-2 OS 2 and UE 48-3 OS 2 units have screw

type terminals.

The UE 48-2 OS 3 and UE 48-3 OS 3 units have

removable terminals.

Internal Circuitry UE 48-2 OS

UE 48-2 OS and UE 48-3 OS Series

Internal Circuitry UE 48-3 OS

Channel 1 Channel 2

RESET

CONTROL-LOGIC

K2

K1

S31 S22S12S11

+

S21

A1 A2 S33 S34 S35

(–)(+)

13 23 33

14 24 34S33

(+)SUPPLY

A1 A2 S34 S35 13 23 31

S21 S11 S33 S12 S31 S22 14 24 32

RESET

Control-Logic

SUPPLYCH 1 CH 2

K1

K2

+ +

+ +

Page 45: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 458 009 607/18-09-03

UE 48-2 OS and UE 48-3 OS Series

Technical Data UE 48

min. typ. max.General System Data

Supply voltage to A 1 / A 2Electrical output circuit > 25 V AC / 60 V DC PELVElectrical output circuit < 25 V AC / 60 V DC PELV or SELV

Safety Category: EN 954-1 4

Stop Category: EN 60 204 0

Supply voltage VS (A 1 / A 2) 20.4 V AC/DC 24 V AC/DC 26.4 V AC/DC

Power consumptionAC Mode 4.6 VADC Mode 2.1 W

Residual ripple in DC mode(within the limits of V

S) 2.4 V

PP

Nominal frequency in AC mode 50 Hz 60 Hz

Control voltage S 33 / S 11 and S 21Control voltage 17.4 V DC 22 V DC

Control current 40 mA 100 mA

Electrical short circuit between S 33 / S 11 and S 21) 300 mA

Fuse Electronic Fuse

Reaction time by cross connection 50 ms

Switch-on time after cross connection detection 50 ms

Galvanic separationbetween A 1 / A 2 and S 21, S 11, S 33 n o

Input circuits (S 12, S 31, S 22, S 34, S 35)Input voltage (S 12 and S 31)

HIGH 17.4 V DC 26.4 V DCLOW –3 V DC +5 V DC

Input current at S 12 and S 31 / S 22 40 mA 100 mA

Input current at S 34 / S 35 5 mA 50 mA

Reset timeManual (S 33 / S 34) 40 msAutomatic (ESPE: S 33 / S 35; potential free: S 12 / S 35) 80 ms

Activation time for Reset button 50 ms

Minimum switch-off time / minimum switch-on time 7 ms

Permitted test pulse time / Test frequency 1000 µs / 10 s–1

Line resistance at the input circuit 35 Ohm

Synchronisation time 70 ms

Output circuits (13 - 14, 23 - 24, 31 - 32 / 33 - 34)Response time (K 1 / K 2) 25 ms

Minimum switch-off time 70 ms 130 ms

Relay contacts UE 48-2 OS 2 Normally open contacts (NO), safety relevant1 Normally closed contact (NC), not safety relevant

Relay contacts UE 48-3 OS 3 Normally open contacts (NO), safety relevant

Contact type positively guided

Contact material Silver alloy; gold-plated

Load capacity of contactsSwitching voltage 10 V AC/DC 230 V AC / 30 V DCSwitching current 10 mA 6 ATotal current across all contacts 12 A

Application Category to EN 60 947-5-1 AC-15 Ue 230 V AC, Ie 4 A (360 c/h)

AC-15 Ue 230 V AC, Ie 3 A (3600 c/h)

DC-13 Ue 24 V DC, Ie 4 A (360 c/h)

DC-13 Ue 24 V DC, Ie 2.5 A (3600 c/h)

Permitted switching frequency 3600 c/h

Service life, mechanical (switching cycles) 1 x 107

Service life, electrical (dependent upon loading) 2 x 106

Operating data see Page 47

Weight 0.2 kg

Page 46: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

46 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03

Order reference list for UE 48

Type Outputs Connections Electrical supply Part No.

Screw type terminals Removable terminals 24 V AC/DC

UE 48 - 2 OS 2 D2 6 024 915

UE 48 - 2 OS 3 D2 6 024 916

UE 48 - 3 OS 2 D2 6 025 089

UE 48 - 3 OS 3 D2 6 025 097

UE 48-2 OS and UE 48-3 OS Series

Page 47: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 478 009 607/18-09-03

Common Technical Specifications

min. typ. max.

Surge voltage rating (VImp.) 4 kV

Excess Voltage Category III

Contamination rating of the unit (EN 50 178)external 3internal 2

Voltage rating 300 V AC

Test voltage Veff

(50 Hz) EN 60 439-1 2.0 kV

Protection typeHousing IP 40Terminals IP 20

Radio interference DIN EN 61 000-6-4UE 10-4 XT, UE 11-4 DX, UE 42-2 HD,UE 44-3 SL and UE 45-3 S1 only EN 60 947-1 02/99

Screening against interference DIN EN 61 000-6-2

UE 10-4 XT, UE 11-4 DX, UE 42-2 HD,UE 44-3 SL and UE 45-3 S1 only EN 60 947-1 02/99

Ambient operating temp. –25 °C +55 °C

Storage temperature –25 °C +75 °C

Cross sections of electrical conductorssingle strand wire (2 x, identical cross section) 0.14 mm2 0.75 mm2

single strand wire (1 x) 0.14 mm2 2.5 mm2

fine stranded wire with terminal crimps(2 x, identical cross section) 0.25 mm2 0.5 mm2

fine stranded wire with terminal crimps (1 x) 0.25 mm2 2.5 mm2

UE 43-3 MF and UE 43-6 MF onlysingle strand wire (2 x, identical cross section) 0.75 mm2 2.5 mm2

single strand wire (1 x) 0.75 mm2 2.5 mm2

fine stranded wire with terminal crimps(2 x, identical cross section) 0.5 mm2 1.5 mm2

fine stranded wire with terminal crimps (1 x) 0.5 mm2 1.5 mm2

UE 10 - UE 48 Safety Relays

Page 48: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

48 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03

Activation time ofReset button

Minimumswitch-off time (Inputs)

Minimumswitch-off time (Outputs)

Minimum switch-on time

Monitoring ofsimultaneous activation(UE 42-2 HD only)

Off-delay time

On-delay time

Reset time

Response time

Switch-on time

Synchronisation time

Time in which a Reset button must be pressed, in order to

ensure the resetting of the safety relay.

The minimum time the inputs need to stay off in order for

the unit to recognise an off signal. Times under this value

may not be recognised as an off signal.

The unit specific minimum time the outputs must stay off.

This insures that the internal relays can fall back to their

rest state.

The minimum time the inputs need to be HIGH before a

Restart can be enabled.

The simultaneous pressing of the Start buttons is

monitored, and is specified for two-hand control systems.

Only when both safety input signals change their state

within 0.5 sec will the output contacts be switched.

Time by which the switching off of the output contacts is

delayed. This time is either fixed or adjustable depending

on module type.

Time by which the switching on of the output contacts is

delayed. For safety relays having an on-delay, the time

settings are adjustable.

Time period between the activation of the Reset and

when the ouput contacts switch on.

The time starts:

- during Manual Reset with the release of the Reset

button

- during Automatic Reset with the closing of the input

circuits (e. g. closing of the door).

The time between the activation of the inputs (e. g.

E Stop is pressed), and the switching off of the outputs.

Time, which the safety device needs after applying the

supply voltage in order to be ready for operation.

Switching of the input circuits within a fixed time span is

monitored. Only if input 2 closes by no later than 0.5 sec

after input 1 do the ouput circuits close. If input 2 closes

before input 1, the monitoring of synchronisation will not

take place, and the output circuits will close. This

monitoring occurs in Automatic Reset.

UE 10 - UE 48 Safety Relays

Glossary

Page 49: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 498 009 607/18-09-03

Application Overview

Safety Navigator

Sa

fety

Ca

teg

ory

to

EN

95

4-1

Sta

nd

ard

un

it

Exp

an

sio

n m

od

ule

Em

erg

en

cy S

top

(E

N 4

18

)

Sa

fety

Sw

itch

(E

N 1

08

8)

Tw

o-h

an

d c

on

tro

l syste

ms (

Typ

III

C /

EN

57

4)

Sa

fety

ma

ts (

on

ly a

va

ila

ble

in

4-w

ire

te

ch

no

log

y)

Ele

ctr

o-S

en

sit

ive

P

rote

cti

ve

E

qu

ipm

en

t (E

SP

E)

No

rma

lly o

pe

n c

on

tacts

(N

O)

No

rma

lly c

lose

d c

on

tacts

(N

C)

On

-de

lay

Off

-de

lay

Sin

gle

-ch

an

ne

l co

ntr

ol

syste

m

Du

al-

ch

an

ne

l co

ntr

ol

syste

m

Cro

ss cir

cu

it d

ete

cti

on

Au

tom

ati

c

Re

se

t

Ma

nu

al

Re

se

t (m

on

ito

red

)

Mo

nit

ori

ng

of

sim

ult

an

eo

us a

cti

va

tio

n (

0.5

s)

Syn

ch

ron

isa

tio

n m

on

ito

rin

g (

0.5

s)

Ho

usin

g w

idth

(m

m)

1) The wires for the input and output signals shall be routed outside the control cabinet according to the safety category to be used2) Same as protective device3) Same as the main unit4) 4 normally open contacts / 2 normally closed contacts with off-delay function

UE 42-2 HD 4 � � � 2 1 � � � 22.5

UE 23-2 MF 4 1) � � � 2 1 � � � 22.5

UE 43-2 MF 4 � � � 2 1 � � � � � � 22.5

UE 43-3 MF 4 � � � 3 1 � � � � � � 45

UE 43-6 MF 4 � � � 6 4 � � � � � � 90

UE 10-3 OS 2) � � 3 1 � � 22.5

UE 48-2 OS 4 � � � � � 2 1 � � � � � 22.5

UE 48-3 OS 4 � � � � � 3 0 � � � � � 22.5

UE 44-3 SL 4 � � � 2 � � � � � � � 22,5

UE 45-3 S1 4 � � � 2 � � � � � � � 22.5

UE 10-4 XT 3) � 4 2 22.5

UE 11-4 DX 3) � 4/2 4) 22.5

General notes Applications Outputs Features

Page 50: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

50 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03

Sample wiring diagrams

Contents

UE 10-3 OSwith C 4000 Safety Light Curtain ......................................... 51

with C 2000 Safety Light Curtain ......................................... 52

with S 3000 Safety Laser Scanner ..................................... 52

UE 23-2 MFwith Emergency Stop ................................................................... 53

UE 42-2 HDwith two-hand control .................................................................. 54

with two Safety Switches .......................................................... 54

UE 43-2 MFwith two i10 Safety Switches ................................................. 55

UE 43-3 MFwith two Safety Switches .......................................................... 56

with Emergency Stop ................................................................... 57

UE 43-6 MFwith two Safety Switches .......................................................... 58

UE 44-3 SLwith Mechanical Locking Safety Switch ............................. 59

UE 45-3 S1with two Safety Switches .......................................................... 60

UE 48-2 OSwith C 4000 Safety Light Curtain ......................................... 61

with FGS Safety Light Curtain ................................................ 61

with PLS Safety Laser Scanner .............................................. 62

Page 51: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 518 009 607/18-09-03

UE 10 - UE 48 Safety Relays

C 4000 Standard/Advanced connected to UE 10-3 OS Safety Relay,

with Manual Reset and external device monitoring (active)

+ 24 V

0 V

C 4000 S C 4000 R UE 10-3 OS

B 1 B 3 Y 1 13 23 33 41

B 2 B 4 Y 2 14 24 34 42

1

3

4

5

6

2

FE

+ 24 V

Test

n. c.

n. c.

n. c.

0 V

FE

+ 24 V

RES

EDM

OSSD 1

OSSD 2

0 V

FE

1

5

6

3

4

2

FE

S 1

Sample wiring diagrams UE 10-3 OS

C 4000 Micro connected to UE 10-3 OS Safety Relay,

with Manual Reset and external device monitoring (active)

+ 24 V

0 V

C 4000 S C 4000 R UE 10-3 OS

B 1 B 3 Y 1 13 23 33 41

B 2 B 4 Y 2 14 24 34 42

2

5

1

3

4

7

FE

+ 24 V

Test

n. c.

n. c.

n. c.

0 V

FE

+ 24 V

RES

EDM

OSSD 1

OSSD 2

0 V

FE

2

1

4

5

6

7

FE

S 1

Page 52: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

52 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03

UE 10 - UE 48 Safety Relays

+ 24 V

0 V

S 1

S 3000

BN

RD

YE

BU/WH

RD/BU

WH/BN

PK

GN

BU

UE 10-3 OS

B 1 B 3 Y 1 13 23 33 41

B 2 B 4 Y 2 14 24 34 42

1

5

6

7

8

9

4

3

2

S 3000 Standard to UE 10-3 OS Safety Relay,

with Manual Reset and external device monitoring (active)

Sample wiring diagrams UE 10-3 OS

+ 24 V

0 V

S 1

WH

BN

GN

GY

BU

C 2000 S C 2000 R

WH

BN

GN

YE

GY

PK

BU

Sel 1

+24 V

Sel 2

n. c.

Test

n. c.

0 V

Shield Shield

0 V

OSSD 2

OSSD 1

EDM

Sel 2

+24 V

Sel 1

6 2

UE 10-3 OS

B 1 B 3 Y 1 13 23 33 41

B 2 B 4 Y 2 14 24 34 42

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

C 2000 Advanced to UE 10-3 OS Safety Relay,

with Manual Reset and external device monitoring (active)

Page 53: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 538 009 607/18-09-03

+24 V

0 V

K 1 K 2

S 1

k 1

k 2

Y1 A1 13 23 31

Y3 A2 14 24 32

UE 23-2 MF

S 0

Emergency Stop to UE 23-2 MF Safety Relay,

with Manual Reset and external device monitoring (EDM)

UE 10 - UE 48 Safety Relays

Sample wiring diagram UE 23-2 MF

Page 54: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

54 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03

UE 10 - UE 48 Safety Relays

Sample wiring diagrams UE 42-2 HD

+ 24 V

0 V

S 1

k 1

K 1 K 2

k 2

S 2

UE 42-2 HD

Y12 S14 Y22 Y24 A1 13 23 31

Y11 Y21 Y1 Y2 A2 14 24 32

Two-hand control with UE 42-2 HD Safety Relay,

dual-channel system, with automatic start and external device monitoring (EDM)

+ 24 V

0 V

k 1

K 1 K 2

k 2

UE 42-2 HD

Y12 S14 Y22 Y24 A1 13 23 31

Y11 Y21 Y1 Y2 A2 14 24 32

Two Safety Switches connected to UE 42-2 HD Safety Relay,

dual-channel system, with Automatic Reset and external device monitoring (EDM)

Page 55: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 558 009 607/18-09-03

UE 10 - UE 48 Safety Relays

Sample wiring diagram UE 43-2 MF

Two Safety Switches i 10 to UE 43-2 MF Safety Relay,

dual-channel control system, with Manual Reset and external device monitoring (EDM)

+24 V

0 V

H 4 (rd) K 1 K 2

S 1

k 1

k 2

S33 S11 S31 S21 A1 13 23 31

S34 S35 S12 S22 A2 14 24 32

UE 43-2 MF

21 13

22 14

B2

21 13

22 14

B1

i10

i10

Page 56: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

56 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03

UE 10 - UE 48 Safety Relays

+ 24 V

0 V

k 1

K 1 K 2

k 2

UE 43-3 MF 2 D3

Y14 Y13 Y11 Y21 A1 13 23 33 41

Y31 Y12 Y12 Y22 A2 14 24 34 42

Two Safety Switches to UE 43-3 MF Safety Relay,

dual-channel system, with Automatic Reset and external device monitoring (EDM)

Sample wiring diagrams UE 43-3 MF

+ 24 V

0 V

k 1

K 1 K 2

k 2

UE 43-3 MF 2 D3

Y14 Y13 Y11 Y21 A1 13 23 33 41

Y31 Y12 Y12 Y22 A2 14 24 34 42

S 1

Two Safety Switches to UE 43-3 MF Safety Relay,

dual-channel system, with Manual Reset and external device monitoring (EDM)

Page 57: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 578 009 607/18-09-03

UE 10 - UE 48 Safety Relays

+ 24 V

0 V

k 1

A) B)

k 2

S 1

+ 24 V

0 V

UE 43-3 MF 2 D3

Y13 Y11 Y14 A1 13 23 33 41

Y31 Y12 Y21 Y22 A2 14 24 34 42

UE 43-3 MF 2 D3

Y13 Y11 Y14 A1 13 23 33 41

Y31 Y12 Y21 Y22 A2 14 24 34 42

k 1

k 2

S 0S 0

S 1

K 1 K 2K 1 K 2

Emergency Stop Switch connected to UE 43-3 MF 2 D3 Safety Relay,

with Manual Reset and external device monitoring. A) single-channel system, B) dual-channel system

Sample wiring diagrams UE 43-3 MF

Page 58: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

58 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03

Two Safety Switches to UE 43-6 MF Safety Relay,

dual-channel system, with Manual Reset and external device monitoring (EDM)

+24 V

0 V

UE 43-6 MF

S21 S11 S33 Y3 Y1 Y2 A1 13 23 33 43 53 63 71 81 91 01

S22 S12 S34 S 37 Y1 A2 14 24 34 44 54 64 72 82 92 02

11

12

23

24

11

12

23

24

K 1 K 2

B1

i12 SA

i16 S

B2

i12 SA

i16 S

S 1

k 2

k 1

Sample wiring diagram UE 43-6 MF

UE 10 - UE 48 Safety Relays

Page 59: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 598 009 607/18-09-03

UE 10 - UE 48 Safety Relays

Sample wiring diagram UE 44-3 SL

+ 24 V

0 V

K 1 K 2

UE 44-3 SL

S33 S31 S12 S22 A2 14 24 38

S11 S21 S35 S34 A1 13 23 37

12

11 21 33 41 53 E1

23 34 42 54 E2

k 1

k 2

S 1

S 4

i200 Lock

i200 Lock Safety switch (with mechanical locking) connected to UE 44-3 SL Safety Relay,

with Manual Reset and external device monitoring (EDM)

Page 60: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

60 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03

Sample wiring diagram UE 45-3 S1

UE 10 - UE 48 Safety Relays

+ 24 V

0 V

k 1

k 2

S 1

UE 45-3 S1

S21 S35 S34 S33 A1 13 23 37

S11 S31 S12 S22 A2 14 24 38

K 1

K 2M

3

Two Safety Switches connected to UE 45-3 S1 Safety Relay,

dual-channel system, with Manual Reset and external device monitoring (EDM)

Page 61: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 618 009 607/18-09-03

Sample wiring diagrams UE 48-2 OS

+ 24 V

0 V

S 1

C 4000 S C 4000 E

UE 48-2 OS

S33 S11 S12 S31 A1 13 23 31

S34 S35 S21 S22 A2 14 24 32

1

3

4

5

6

2

FE

+ 24 V

Test

n. c.

n. c.

n. c.

0 V

FE

+ 24 V

n. c.

n. c.

OSSD 1

OSSD 2

0 V

FE

1

5

6

3

4

2

FE

k 1

k 2

K 1 K 2

C 4000 Basic to UE 48-2 OS Safety Relay,

with Manual Reset and external device monitoring (EDM)

+ 24 V

0 V

S 1

FGSS FGSE

UE 48-2 OS

S33 S11 S12 S31 A1 13 23 31

S34 S35 S21 S22 A2 14 24 32

1

3

4

2

7

+ 24 V

Test

Test

0 V

PE

+ 24 V

OSSD 1

OSSD 2

0 V

PE

k 1

k 2

K 1 K 2

PE

1

3

4

2

7

FGS connected to UE 48-2 OS Safety Relay,

with Manual Reset and external device monitoring (EDM)

UE 10 - UE 48 Safety Relays

Page 62: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

62 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03

Sample wiring diagrams UE 48-2 OS

+ 24 V

0 V

S 1

PLS

UE 48-2 OS

S33 S11 S12 S31 A1 13 23 31

S34 S35 S21 S22 A2 14 24 32

3

9

8

1

k 1

k 2

K 1 K 2

PLS connected to UE 48-2 OS Safety Relay,

with Manual Reset and external device monitoring (EDM)

Safety Relays UE 10 - UE 48

Page 63: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

© SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 638 009 607/18-09-03

Page 64: Safety Relays UE 10 – UE 48 Series - LC Automation Relay... · UE 10 - UE 48 Safety Relays Selection Table Single Channel Input UE 23-2 MF UE 43-2 MF UE 43-3 MF UE 43-6 MF UE 45-3

Contact:

A u s t r a l i aPhone +61 3 9497 4100

1800 33 48 02 – tollfreeE-Mail [email protected]

B e l g i q u e / L u x e m b o u r gPhone +32 (0)2 466 55 66E-Mail [email protected]

B r a s i lPhone +55 11 5091-4900E-Mail [email protected]

C e s k á R e p u b l i k aPhone +420 2 57 91 18 50E-Mail [email protected]

C h i n aPhone +852-2763 6966E-Mail [email protected]

D a n m a r kPhone +45 45 82 64 00E-Mail [email protected]

D e u t s c h l a n dPhone +49 (0)2 11 53 01-260E-Mail [email protected]

E s p a ñ aPhone +34 93 480 31 00E-Mail [email protected]

F r a n c ePhone +33 1 64 62 35 00E-Mail [email protected]

G r e a t B r i t a i nPhone +44 (0)1727 831121E-Mail [email protected]

I t a l i aPhone +39 02 27 40 93 19E-Mail [email protected]

J a p a nPhone +81 (0)3 3358 1341E-Mail [email protected]

K o r e aPhone +82-2 786 6321/4E-Mail [email protected]

N e d e r l a n dPhone +31 (0)30 229 25 44E-Mail [email protected]

N o r g ePhone +47 67 81 50 00E-Mail [email protected]

Ö s t e r r e i c hPhone +43 (0)22 36 62 28 8-0E-Mail [email protected]

P o l s k aPhone +48 22 837 40 50E-Mail [email protected]

S c h w e i zPhone +41 41 619 29 39E-Mail [email protected]

S i n g a p o r ePhone +65 6744 3732E-Mail [email protected]

S u o m iPhone +358-9-25 15 800E-Mail [email protected]

S v e r i g ePhone +46 8 680 64 50E-Mail [email protected]

T a i w a nPhone +886 2 2365-6292E-Mail [email protected]

U S A / C a n a d a / M é x i c oPhone +1(952) 941-6780

1 800-325-7425 – tollfreeE-Mail [email protected]

More representatives and agencies in all major industrial nations at www.sick.com

SICK AG • Industrial Safety Systems • Waldkirch • Germany • www.sick.com

8 0

09

60

7/1

8-0

9-0

3 •

KW

/SM

• Pr

inte

d in

Ger

man

y (1

2.0

3) •

Sub

ject

to c

hang

e w

ithou

t prio

r not

ice

• The

spe

cifie

d pr

oduc

t fea

ture

s an

d te

chni

cal d

ata

do n

ot re

pres

ent a

ny g

uara

ntee

• i

nt 1

4.0

2 T

B