sc 2201 hardwired manual changeover...

28
Manual Changeover Non-Programmable Hardwired SC 2201 Non-Programmable Electronic Thermostat Installation, Operation & Application Guide For more information on our complete range of American-made products – plus wiring diagrams, troubleshooting tips and more, visit us at www.icmcontrols.com • For use with Heat Pumps • Up to 2-Stage Heat, 2-Stage Cool • 30-Minute Power Loss Memory Retention • For use with 24 VAC Systems

Upload: others

Post on 20-Jul-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SC 2201 Hardwired Manual Changeover Non-Programmablehackershomepage.com/World-Famous-Gambling-Cheating... · SC 2201 Hardwired Non-Programmable Electronic Thermostat Installation,

Manual ChangeoverNon-Programmable

HardwiredSC 2201Non-Programmable Electronic Thermostat

Installation, Operation & Application GuideFor more information on our complete range of American-made products – plus wiring diagrams, troubleshooting tips and more, visit us at www.icmcontrols.com

•ForusewithHeatPumps

•Upto2-StageHeat,2-StageCool

•30-MinutePowerLossMemoryRetention

•Forusewith24VACSystems

Page 2: SC 2201 Hardwired Manual Changeover Non-Programmablehackershomepage.com/World-Famous-Gambling-Cheating... · SC 2201 Hardwired Non-Programmable Electronic Thermostat Installation,

Table of Contents

CAUTION!:Thisthermostatshouldbeinstalledbytrainedtechniciansonly.Adheretoalllocalandnationalcodes.Disconnectallpowertothesystembeforeinstalling,removing,orcleaning.

PartsDiagram........................................................1Specifications........................................................2Features/Benefits.................................................. 2PackageContents/ToolsRequired........................ 2ImportantSafetyInformation................................. 3GeneralDescription............................................... 2ToRemoveExistingThermostat............................ 4ReplacingWiringLabels........................................ 4ToInstallThermostat............................................. 5TestingtheThermostat.......................................... 6LEDIndicators.......................................................8Operation...............................................................9

WiringDiagrams.................................................. 11 CarrierSplitStreamCondensers........................................... 11

Coleman3000Series............................................................12

ComfortmakerCYCSeries....................................................13

Heil-Quaker867.814SeriesandPH50Series......................14

PayneReliantandEnduraModel..........................................15

Rheem/Ruud: -PGB,-PFA,-PCB,

-PLA,and-PKASeries.................................16

Goodman,Janitrol,Trane/AmericanStandard......................17

York-E1CS,-E1FB,E1FH.....................................................18

LennoxCB19 ......................................................................19

LennoxHP19andHP20........................................................20

LennoxHP21withCB21PCB...............................................21

LennoxHP22withCB19PCB...............................................22

FHP1Stage..........................................................................23

FHP2Stage..........................................................................24

Troubleshooting...................................................25

Page 3: SC 2201 Hardwired Manual Changeover Non-Programmablehackershomepage.com/World-Famous-Gambling-Cheating... · SC 2201 Hardwired Non-Programmable Electronic Thermostat Installation,

1

Parts Diagram

Page 4: SC 2201 Hardwired Manual Changeover Non-Programmablehackershomepage.com/World-Famous-Gambling-Cheating... · SC 2201 Hardwired Non-Programmable Electronic Thermostat Installation,

2

SpecificationsInput:• Voltage:24VAC(18-30VAC)Output:• Maximum:1ampmaximumloadperterminal (4amptotalmaximumloadforallterminals)TemperatureRanges:• Temperaturecontrolrange:45°Fto90°F(7°Cto32°C)Accuracy:±1°F(±0.5°C)• Differentialrange:1°Fto3°F(0.5°Cto1.5°C)Systemconfigurations:Multi-stageheatpump(two-stageheat,two-stagecool)Terminations:R,C,E,Y1,Y2,O,B,G,L,W2Secondstageactivationinheatmode:2°belowfirststage(notadjustable)Secondstageactivationincoolmode:2°abovefirststage(notadjustable)

SETROOM

DIFFTemperaturedifferentialsetting

Roomtemperature

Roomtemperaturesetpoint

Package Contents/Tools RequiredPackageincludes: SimpleComfort®2201non-programmablethermostatonbase,thermostatcover,wiringlabels,

screwsandwallanchors,Installation,OperationandApplicationGuide.Toolsrequiredforinstallation:Drillwith3/16”bit,hammer,screwdriver.

Features/Benefits• Multi-stageheating/coolingcontrol• Multi-coloredLEDindicatorsforsystemstatus• Zonesystemcompatibleasamasterthermostat• FahrenheitdisplayandoperationcanbechangedtoCelsius

• Adjustabletemperaturedifferential: 1°Fto3°F (0.5°Cto1.5°C)

• Automaticheatingsystemshutdowniftemperatureexceeds90°F(32°C)

• 30-minutepowerinterruptionmemoryretention• Resetbuttonfordifferentialtemperatureadjustment• Independentsetpointsforheatandcool

Page 5: SC 2201 Hardwired Manual Changeover Non-Programmablehackershomepage.com/World-Famous-Gambling-Cheating... · SC 2201 Hardwired Non-Programmable Electronic Thermostat Installation,

3

Important Safety Information

General DescriptionTheSimpleComfort®2201isintendedtooperateandiscompatiblewith24VACresidentialheatpumpswithupto2-stageheat/2-stagecool.Itwilloperatewithmulti-stageheatpumpsystemsthataremanualchangeoverandhaveauxiliaryoremergencyheating.Therearenooptionalitemsrequiredforstandardinstallations.Thisthermostatisalsocompatibleasamasterthermostatinzonedsystemapplications.

TheSimpleComfort®2201willautomaticallycontroltheheatand/orairconditioningsystem.Whenusedproperly,thisthermostatcanreduceheatingandcoolingcoststhroughouttheyear.

• Alwaysturnoffpoweratthemainpowersourcebyunscrewingfuseorswitchingcircuitbreakertotheoffpositionbeforeinstalling,removing,cleaning,orservicingthisthermostat

• Readalloftheinformationinthismanualbeforeinstallingthisthermostat• Thisthermostatshouldbeinstalledonlybyaprofessionalcontractor• Thisisa24VAClow-voltagethermostat;donotinstallonvoltageshigherthan30VAC• Allwiringmustconformtolocalandnationalbuildingandelectricalcodesandordinances• Donotswitchsystemtocooliftheoutdoortemperatureisbelow50°F(10°C);thiscandamagetheairconditioningsystemandmaycausepersonalinjury

• Thethermostatwillnotcontrolyourheating/airconditioningsystemwithoutpower;itrequiresacontinuous24VACcircuitforpropersystemcontrol

• Usethisthermostatonlyasdescribedinthismanual• Whilecleaning,donotgetsoapdirectlyonthermostatswitchesorLCDreadout;onlyuseadampclothwithamildsoaptowipeoutsideofthermostatcover

Page 6: SC 2201 Hardwired Manual Changeover Non-Programmablehackershomepage.com/World-Famous-Gambling-Cheating... · SC 2201 Hardwired Non-Programmable Electronic Thermostat Installation,

4

ELECTRICALSHOCKHAZARD – Turn off power at the main service panel by removing the fuse or switching the appropriate circuit breaker to the Off position before removing the existing thermostat.

1. Turnoffpowertotheheatingandcoolingsystembyremovingthefuseorswitchingofftheappropriatecircuitbreaker.

2. Removecoverofoldthermostat.Thisshouldexposethewires.3. Labeltheexistingwireswiththeenclosedwirelabelsbeforeremovingwires.Seetablebelowforoldand

newlabelidentification.4. Afterlabelingwires,removewiresfromwireterminals.5. Removeexistingthermostatbasefromwall.6. Refertothefollowingsectionforinstructionsonhowtoinstallthisthermostat.

Replacetheoldlabelswiththeenclosednewlabels:

Old New TypeR,V-VRorVR-R R 24VAC,return

Y,Y1orM Y1 Stage1cooling/heatingcircuit

OorR O Reversingvalve(coolingmode)

B B Reversingvalve(heatmode)

GorF G Fancontactorcircuit

Y2 Y2 2ndstagecoolingcircuit

W1,W2orW-U W2 2ndstageheatingcircuit

LorX L SystemmonitorLED

E E Emergencyheatingcircuit

C,XorB C 24VAC,transformercommonside

Replacing Wiring Labels

To Remove Existing Thermostat

Page 7: SC 2201 Hardwired Manual Changeover Non-Programmablehackershomepage.com/World-Famous-Gambling-Cheating... · SC 2201 Hardwired Non-Programmable Electronic Thermostat Installation,

5

ELECTRICALSHOCKHAZARD – Turn off power at the main service panel by removing the fuse or switching the appropriate circuit breaker to the Off position before removing the existing thermostat.

IMPORTANT: Thermostatinstallationmustconformtolocalandnationalbuildingandelectricalcodesandordinances.

IMPORTANT: Thisthermostatiscompatiblewith100%lockoutsystems.Toresetthesystem,turnthermostattoOffpositionforatleast60seconds.

Note:Mountthethermostataboutfivefeetabovethefloor.Donotmountthethermostatonanoutsidewall,indirectsunlight,behindadoor,orinanareaaffectedbyaventorduct.

1. Turnoffpowertotheheatingandcoolingsystembyremovingthefuseorswitchingofftheappropriatecircuitbreaker.

2. PutMode switchinOffposition.

3. PutFan switchinAutoposition.

4. Toremovecover,insertandtwistacoinorscrewdriverintheslotsonthesidesofthethermostat.

5. Putthermostatbaseagainstthewallwhereyouplantomountit(Besurewireswillfeedthroughthewireopeninginthebaseofthethermostat).

6. Marktheplacementofthemountingholes.

7. Setthermostatbaseandcoverawayfromworkingarea.

8. Usinga3/16”drillbit,drillholesintheplacesyouhavemarkedformounting.

9. Useahammertotapsuppliedanchorsinmountingholes.

10. Alignthermostatbasewithmountingholesandfeedthecontrolwiresthroughwireopening.

11. Usesuppliedscrewstomountthermostatbasetowall.

Cool Off Heat Emer Auto On

Mode Fan

To Install Thermostat

Page 8: SC 2201 Hardwired Manual Changeover Non-Programmablehackershomepage.com/World-Famous-Gambling-Cheating... · SC 2201 Hardwired Non-Programmable Electronic Thermostat Installation,

6

12. Insertstripped,labeledwiresinmatchingwireterminals.SeeWiringDiagramssectionofthismanual(Pages11-24).

CAUTION!:Besureexposedportionofwiresdoesnottouchotherwires.

13. Tightenscrewsonterminalblock.Gentlytugwiretobesureofproperconnection.Doublecheckthateachwireisconnectedtotheproperterminal.

14. Sealholeforwireswithnon-flammableputtyorinsulation.

15. Replacecoveronthermostatbysnappingitinplace.

16. Turnonpowertothesystematthemainservicepanel.

17. Testthermostatoperationasdescribedinthefollowingsection.

CAUTION!: Donotswitchsystemtocooliftheoutdoortemperatureisbelow50°F(10°C).Thiscandamagetheairconditioningsystemandmaycausepersonalinjury.

1. PuttheMode switchtoCoolposition.

2. Pressthe buttonuntilthetemperaturesettingisatleast3degreesbelowtheroomtemperature.Theairconditioningsystemandfanshouldturnonwithinafewseconds.

3. PuttheMode switchintheOffposition.Theairconditioningsystemshouldturnoff.Thefanmayhaveadelay.

Note:PressingtheResetbuttonwillbypassthe5-minuteanti-shortcyclecompressorprotection.

Cool Off Heat Emer

Cool Off Heat Emer

Mode

Mode

Testing the Thermostat

Page 9: SC 2201 Hardwired Manual Changeover Non-Programmablehackershomepage.com/World-Famous-Gambling-Cheating... · SC 2201 Hardwired Non-Programmable Electronic Thermostat Installation,

7

Note:WhileinCoolorHeatmode,oncethethermostatturnsthesystemoff,abuilt-indelaykeepsthecompressorfromturningonforabout5minutes.Thisprotectsthecompressor.

4.PuttheMode switchtotheHeatposition.

5.Pressthe buttonuntilthetemperaturesettingisatleast3degreesaboveroomtemperature.Theheatingsystemshouldturnon.

Note:Thecompressormaynotturnonagainfor5minutes.

6.PuttheMode switchtotheOffposition.Theheatingsystemshouldturnoff.Onceagainthefanmayhaveadelay.

7.PuttheFan switchtotheOnposition.Theblowerfanshouldturnon.

8.PuttheFan switchtotheAutoposition.Theblowerfanshouldturnoff.

Ifallfunctionsoperateproperly,thethermostatisinstalledcorrectly.

If the thermostat does not operate properly:

• Checkallwiringconnections

• SeeTroubleshooting(Page25)

Cool Off Heat Emer

Auto On

Auto On

Cool Off Heat Emer

Mode

Mode

Fan

Fan

Page 10: SC 2201 Hardwired Manual Changeover Non-Programmablehackershomepage.com/World-Famous-Gambling-Cheating... · SC 2201 Hardwired Non-Programmable Electronic Thermostat Installation,

8

TherearethreeLEDindicatorslocatedonthefrontofthethermostat.Theyaredesignedtoinformyouofthefollowing:

AUX (GREEN): Thisturnsonwhentheauxiliary(back-up)heatingisinoperation.Thisisthesecond(non-economy)stageofheat.Itturnson2degreesbelowfirststageandisnotadjustable.

CHECK (RED): Whenthisturnson,amalfunctionhasoccurredsomewhereintheheatpumpsystem.Pleasecontactaqualifiedservicetechnicianassoonaspossibletocheckyoursystem.

EMER (RED): Thislightturnsonwhenevertheemergencyheatismanuallyselected(systemswitchisintheEMERposition).Whileintheemergencyheatmode,theheatpumpcompressorisoff,andtheemergencyheat(sameastheauxiliaryheat)maintainsthesetpointtemperature.

Cool Off Heat Emer OnAutoAux Check Emer

EMER (RED)

CHECK (RED)

AUX (GREEN)

LED Indicators

Page 11: SC 2201 Hardwired Manual Changeover Non-Programmablehackershomepage.com/World-Famous-Gambling-Cheating... · SC 2201 Hardwired Non-Programmable Electronic Thermostat Installation,

9

SettingaNewTemperatureDifferentialIMPORTANT: Thedefaulttemperaturedifferentialisfactorysetat1°F.Whenyourroomtemperaturevariesby1°F,the

thermostatturnsyoursystemon.Ifyounoticeyoursystemturningonandofftoofrequently,increasethetemperaturedifferentialaccordingly.

Step1: RemovecoverandpressResetbuttononce.

Step2: ThedisplaywillshowThisisthetemperaturedifferentialsetting.

Step3: Pressthe or buttontoadjustthetemperaturedifferentialdownorup.

Thedisplaywillreturntotheroomtemperaturedisplayfivesecondsafterthelastinput.Thenewtemperaturedifferentialsettingwillbesaved.

SettingtheRoomTemperature(SetpointTemperature)Step1: Pressthe or button;thecurrenttemperaturesetpointdisplays.

Step2: Pressthe or buttonuntilthedesiredtemperaturesetpointdisplays.

Note: Holdingdowneitherthe or buttonwillscrollthetemperaturedisplay.

Thenewtemperaturesettingisautomaticallysaved.After5seconds,thedisplayreturnstoshowingthecurrentroomtemperature.

Operation

Differential Setting °F °C

1 1°F 0.5°C

2 2°F 1.0°C

3 3°F 1.5°C

Page 12: SC 2201 Hardwired Manual Changeover Non-Programmablehackershomepage.com/World-Famous-Gambling-Cheating... · SC 2201 Hardwired Non-Programmable Electronic Thermostat Installation,

10

ChangingFahrenheittoCelsiusThetemperaturedisplaysindegreesFahrenheitasafactorysetdefault.FollowthesestepstochangetodegreesCelsius:

Step1: Removethecover.

Step2: MovetheF/C jumpertothedesiredposition,ForCusingthecenterpinasacommon.

Step3: PresstheResetbuttononceandreinstallthecover.

YourLCDreadoutchangesaccordingly.

StartingtheThermostatStep1: MovetheFan switchintotheAutoposition.

•InAuto,indoorfanrunsonlyduringaheatingorcoolingcycle•InON,indoorfanrunscontinuously

Step2: MovetheMode switchineitherCoolorHeatposition,dependingontheseason.Thethermostatwillnowoperateandmaintaintheroomtemperatureatthedesiredsetpoint.

Note:Whenthethermostatoperatesthesystem,thereisbuilt-incompressorprotection.Afterthecompressorturnsoff,thesystemwillnotturnitbackonforaboutfiveminutes.Thisprotectsthecompressor.

Cool Off Heat Emer

Mode

Auto On

Fan

Page 13: SC 2201 Hardwired Manual Changeover Non-Programmablehackershomepage.com/World-Famous-Gambling-Cheating... · SC 2201 Hardwired Non-Programmable Electronic Thermostat Installation,

11

SimpleComfort® 2201W2 L C Y2EGBOY1R

SimpleComfort® 2201 Electronic Thermostat Conversion to:Carrier Split Stream Condensers and Heat Pump Systems

Car

rier

Sp

lit S

trea

mL

ow

Vo

ltag

e Te

rmin

al B

oar

d

R

Y

O

G

E

W2

L

C

W3

24VAC,Return

CompressorContactor

ReversingValve(CoolingMode)

FanContactorCircuit

EmergencyHeatingCircuit

2ndStageHeatingCircuit

SystemMonitorLED

24VAC,Common

Wiring Diagrams

Page 14: SC 2201 Hardwired Manual Changeover Non-Programmablehackershomepage.com/World-Famous-Gambling-Cheating... · SC 2201 Hardwired Non-Programmable Electronic Thermostat Installation,

12

SimpleComfort® 2201W2 L C Y2EGBOY1R

SimpleComfort® 2201 Electronic Thermostat Conversion to:Coleman 3000 Series Heat Pump SystemsC

ole

man

300

0L

ow

Vo

ltag

e Te

rmin

al B

oar

d

R

Y

B

G

E

W2

L

X

O

24VAC,Return

CompressorContactor

ReversingValve(HeatingMode)

FanContactorCircuit

EmergencyHeatingCircuit

2ndStageHeatingCircuit

SystemMonitorLED

24VAC,Common

Page 15: SC 2201 Hardwired Manual Changeover Non-Programmablehackershomepage.com/World-Famous-Gambling-Cheating... · SC 2201 Hardwired Non-Programmable Electronic Thermostat Installation,

13

SimpleComfort® 2201W2 L C Y2EGBOY1R

SimpleComfort® 2201 Electronic Thermostat Conversion to:Comfortmaker CYC Series Heat Pump SystemsC

om

fort

mak

er C

YC

Lo

w V

olt

age

Term

inal

Bo

ard

R

Y

O

G

W1

W2

X

C

24VAC,Return

CompressorContactor

ReversingValve(CoolingMode)

FanContactorCircuit

2ndStageHeatingCircuit

OutdoorThermostat

DefrostSensor

24VAC,Common

Note 1:E and W2 terminals jumpered at thermostat.Note 2:W2 terminal on Comfortmaker capped at PCB.Note 2:X terminal on Comfortmaker capped at PCB.

(capped)

(capped)

Page 16: SC 2201 Hardwired Manual Changeover Non-Programmablehackershomepage.com/World-Famous-Gambling-Cheating... · SC 2201 Hardwired Non-Programmable Electronic Thermostat Installation,

14

SimpleComfort® 2201W2 L C Y2EGBOY1R

SimpleComfort® 2201 Electronic Thermostat Conversion to:Heil-Quaker 867.814 Series and PH50 Series Heat Pump Systems

Hei

l-Q

uak

er 8

67.8

14 S

erie

s an

d P

H50

Lo

w V

olt

age

Term

inal

Bo

ard

R

Y

O

G

W1

W2

C

24VAC,Return

CompressorContactor

ReversingValve(CoolingMode)

FanContactorCircuit

2ndStageHeatingCircuit(Sequencer1)

3rdStageHeatingCircuit(Sequencer2)

24VAC,Common

Note 1:E and W2 terminals jumpered at thermostat.Note 2:W2 terminal on Heil-Quaker capped at PCB.

(capped)

Page 17: SC 2201 Hardwired Manual Changeover Non-Programmablehackershomepage.com/World-Famous-Gambling-Cheating... · SC 2201 Hardwired Non-Programmable Electronic Thermostat Installation,

15

SimpleComfort® 2201W2 L C Y2EGBOY1R

SimpleComfort® 2201 Electronic Thermostat Conversion to:Payne Reliant and Endura Model Heat Pump Systems

Pay

ne

Rel

ian

t an

d E

nd

ura

Mo

del

Lo

w V

olt

age

Term

inal

Bo

ard

R

Y

O

G

E

W2

L

C

W3

24VAC,Return

CompressorContactor

ReversingValve(CoolingMode)

FanContactorCircuit

EmergencyHeatingCircuit

2ndStageHeatingCircuit

SystemMonitorLED

24VAC,Common

3rdStageHeatingCircuit

Note 1:W3 terminal on Payne PCB capped at PCB.

(capped)

Page 18: SC 2201 Hardwired Manual Changeover Non-Programmablehackershomepage.com/World-Famous-Gambling-Cheating... · SC 2201 Hardwired Non-Programmable Electronic Thermostat Installation,

16

SimpleComfort® 2201W2 L C Y2EGBOY1R

SimpleComfort® 2201 Electronic Thermostat Conversion to:Rheem/Ruud: -PGB, -PFA, -PCB, -PLA, and -PKA Series Heat Pump Systems

Rhe

em/R

uud:

-PG

B, -

PFA

, -P

CB

, -P

LA, a

nd -P

KA

Lo

w V

olt

age

Term

inal

Bo

ard

R

Y

B

G

W2

L

X

O

24VAC,Return

CompressorContactor

ReversingValve(HeatingMode)

FanContactorCircuit

2ndStageHeatingCircuit

SystemMonitorLED

24VAC,Common

Note 1:E and W2 terminals jumpered at thermostat.

Page 19: SC 2201 Hardwired Manual Changeover Non-Programmablehackershomepage.com/World-Famous-Gambling-Cheating... · SC 2201 Hardwired Non-Programmable Electronic Thermostat Installation,

17

SimpleComfort® 2201 Electronic Thermostat Conversion to:Goodman, Janitrol, Trane/American Standard Heat Pump Systems

SimpleComfort® 2201W2 L C Y2EGBOY1R

Goo

dman

, Jan

itrol

, Tra

ne/A

mer

ican

Sta

ndar

dL

ow

Vo

ltag

e Te

rmin

al B

oar

d

R

Y

O

G

X2

W-U

B

T

24VAC,Return

CompressorContactor

ReversingValve(CoolingMode)

FanContactorCircuit

2ndStageHeatingCircuit

24VAC,Common

Note 1:E and W2 terminals jumpered at thermostat.Note 2:X2 terminal on Goodman, etc. capped at PCB.Note 2:T terminal on Goodman, etc. capped at PCB.

(capped)

(capped)

Page 20: SC 2201 Hardwired Manual Changeover Non-Programmablehackershomepage.com/World-Famous-Gambling-Cheating... · SC 2201 Hardwired Non-Programmable Electronic Thermostat Installation,

18

SimpleComfort® 2201W2 L C Y2EGBOY1R

SimpleComfort® 2201 Electronic Thermostat Conversion to:York -E1CS, -E1FB, E1FH Heat Pump Systems

Yo

rk -

E1C

S, -

E1F

B, E

1FH

L

ow

Vo

ltag

e Te

rmin

al B

oar

d

R

Y

O

G

W

X

B

24VAC,Return

CompressorContactor

ReversingValve(CoolingMode)

FanContactorCircuit

2ndStageHeatingCircuit

SystemMonitorLED

24VAC,Common

Note 1:E and W2 terminals jumpered at thermostat.

Page 21: SC 2201 Hardwired Manual Changeover Non-Programmablehackershomepage.com/World-Famous-Gambling-Cheating... · SC 2201 Hardwired Non-Programmable Electronic Thermostat Installation,

19

SimpleComfort® 2201W2 L C Y2EGBOY1R

SimpleComfort® 2201 Electronic Thermostat Conversion to:Lennox CB19 Heat Pump Systems

Len

no

x C

B19

Lo

w V

olt

age

Term

inal

Bo

ard

R

Y

O

G

E

W

L

C

T

24VAC,Return

CompressorContactor

ReversingValve(CoolingMode)

FanContactorCircuit

EmergencyHeatingCircuit

2ndStageHeatingCircuit

SystemMonitorLED

24VAC,Common

Page 22: SC 2201 Hardwired Manual Changeover Non-Programmablehackershomepage.com/World-Famous-Gambling-Cheating... · SC 2201 Hardwired Non-Programmable Electronic Thermostat Installation,

20

SimpleComfort® 2201W2 L C Y2EGBOY1R

SimpleComfort® 2201 Electronic Thermostat Conversion to:Lennox HP19 and HP20 Heat Pump Systems

Len

no

x H

P19

an

d H

P20

Lo

w V

olt

age

Term

inal

Bo

ard

V-VR

M

R

F

E

Y

X

24VAC,Return

CompressorContactor

ReversingValve(CoolingMode)

FanContactorCircuit

EmergencyHeatingCircuit

2ndStageHeatingCircuit

24VAC,Common

Page 23: SC 2201 Hardwired Manual Changeover Non-Programmablehackershomepage.com/World-Famous-Gambling-Cheating... · SC 2201 Hardwired Non-Programmable Electronic Thermostat Installation,

21

SimpleComfort® 2201W2 L C Y2EGBOY1R

SimpleComfort® 2201 Electronic Thermostat Conversion to:Lennox HP21 with CB21 PCB Heat Pump Systems

Len

no

x H

P21

wit

h C

B21

PC

BL

ow

Vo

ltag

e Te

rmin

al B

oar

d

R-VR

Y

O

F

E

W

L

X

Y2

24VAC,Return

CompressorContactor

ReversingValve(CoolingMode)

FanContactorCircuit

EmergencyHeatingCircuit

2ndStageHeatingCircuit

24VAC,Common

2ndStageCoolingCircuit

SystemMonitorLED

Page 24: SC 2201 Hardwired Manual Changeover Non-Programmablehackershomepage.com/World-Famous-Gambling-Cheating... · SC 2201 Hardwired Non-Programmable Electronic Thermostat Installation,

22

SimpleComfort® 2201W2 L C Y2EGBOY1R

SimpleComfort® 2201 Electronic Thermostat Conversion to:Lennox HP22 with CB19 PCB Heat Pump Systems

Len

no

x H

P22

wit

h C

B19

PC

BL

ow

Vo

ltag

e Te

rmin

al B

oar

d

R-VR

M

R

F

E

Y

L

X

Y2

24VAC,Return

CompressorContactor

ReversingValve(CoolingMode)

FanContactorCircuit

EmergencyHeatingCircuit

2ndStageHeatingCircuit

24VAC,Common

2ndStageCoolingCircuit

SystemMonitorLED

Page 25: SC 2201 Hardwired Manual Changeover Non-Programmablehackershomepage.com/World-Famous-Gambling-Cheating... · SC 2201 Hardwired Non-Programmable Electronic Thermostat Installation,

23

SimpleComfort® 2201W2 L C Y2EGBOY1R

SimpleComfort® 2201 Electronic Thermostat Conversion to:FHP 1 Stage Heat Pump Systems

FH

P 1

Sta

ge

Lo

w V

olt

age

Term

inal

Bo

ard

R

Y

O

G

E

W

C

24VAC,Return

CompressorContactor

ReversingValve(CoolingMode)

FanContactorCircuit

EmergencyHeatingCircuit

2ndStageHeatingCircuit

24VAC,Common

Note: For units with ECM motors and the 641-065 interface board, connect W2 from the thermostat to W1 at the heat pump.

Page 26: SC 2201 Hardwired Manual Changeover Non-Programmablehackershomepage.com/World-Famous-Gambling-Cheating... · SC 2201 Hardwired Non-Programmable Electronic Thermostat Installation,

24

SimpleComfort® 2201W2 L C Y2EGBOY1R

SimpleComfort® 2201 Electronic Thermostat Conversion to:FHP 2 Stage Heat Pump Systems

FH

P 2

Sta

ge

Lo

w V

olt

age

Term

inal

Bo

ard

R

Y

O

G

C

Y2

24VAC,Return

CompressorContactor

ReversingValve(CoolingMode)

FanContactorCircuit

24VAC,Common

Compressor2Contactor

Note 1:Jumper from W2 to Y2 for 2-compressor systems without electric heat only.

Page 27: SC 2201 Hardwired Manual Changeover Non-Programmablehackershomepage.com/World-Famous-Gambling-Cheating... · SC 2201 Hardwired Non-Programmable Electronic Thermostat Installation,

25

Symptom RemedyThesystemisnotturningon Checkthewiring(seeInstallation,Page5)

LCDisblank Displayisblankwhenvoltageisnotpresentatthethermostat

Checkcircuitbreakerorforanopenfuse

Thermostatdoesnotturnonthesystemasfrequentlyasitshould

Decreasethetemperaturedifferential(seeSettingaNewTemperatureDifferential,Page9)

Thermostatisnotproperlycontrollingthefan Checkthewiring(seeInstallation,Page5)

Thermostatiscontinuouslyturningonandoff Increasethetemperaturedifferential(seeSettingaNewTemperatureDifferential,Page9)

Temperaturedisplayisnotaccurate Yourthermostathastwooptionsfortemperaturereadout:Fahrenheit(default)orCelsius;checkthatthe“jumper”isproperlysettoyourpreference

Plugtheholeforwiringbehindthethermostatwithnon-flammableinsulationtopreventairflowintothethermostat

Troubleshooting

Page 28: SC 2201 Hardwired Manual Changeover Non-Programmablehackershomepage.com/World-Famous-Gambling-Cheating... · SC 2201 Hardwired Non-Programmable Electronic Thermostat Installation,

ONE-YEAR LIMITED WARRANTYTheSellerwarrantsitsproductsagainstdefectsinmaterialorworkmanshipforaperiodofone(1)yearfromthedateofmanufacture.TheliabilityoftheSellerislimited,atitsoption,torepair,replaceorissueanon-casecreditforthepurchasepricesofthegoodswhichareprovidedtobedefective.ThewarrantyandremediessetforthhereindonotapplytoanygoodsorpartsthereofwhichhavebeensubjectedtomisuseincludinganyuseorapplicationinviolationoftheSeller’sinstructions,neglect,tampering,improperstorage,incorrectinstallationorservicingnotperformedbytheSeller.InordertopermittheSellertoproperlyadministerthewarranty,theBuyershall:1)NotifytheSellerpromptlyofanyclaim,submittingdatecodeinformationoranyotherpertinentdataasrequestedbytheSeller.2)PermittheSellertoinspectandtesttheproductclaimedtobedefective.ItemsclaimedtobedefectiveandaredeterminedbySellertobenon-defectivearesubjecttoa$30.00perhourinspectionfee.ThiswarrantyconstitutestheSeller’ssoleliabilityhereunderandisinlieuofanyotherwarrantyexpressed,impliedorstatutory.Unlessotherwisestatedinwriting,Sellermakesnowarrantythatthegoodsdepictedordescribedhereinarefitforanyparticularpurpose.

LIA157-4

Patent No. 424,953

7313 William Barry Blvd., North Syracuse, NY 13212(Toll Free)800-365-5525(Phone)315-233-5266(Fax)315-233-5276

www.icmcontrols.com