schams solar flyer mppt-en

2
Our Company The know-how of Schams-Electronic Ltd. is based on more than 15 years of experience in the development of MPP Solar Charge Con- trollers and is state-of-the-art. Our controllers are used worldwide, even in the Antarctic. Development with modern simulation pro- grammes. MPP-Charge Controller Would you like to guarantee your customers an op- timum of solar power, not only during sunshine, but also during periods of bad weather, in winter and in summer while the accu is not overloaded and the wiring does not require great skills? In this case, you will find our controllers very suitable. The Maximum Power Point controller (MPP) ensures maximum efficiency of the solar module at all times. This may increase the charging rate up to 50%. MPP-Charge Controllers for Wind Power Stations More than 100% increase of charge current with MPP Controllers, through optimized dimensioning of the wind generator station. Optimal adaptation of battery and wind generator at varying windspeeds. Complete solution with the combination of all neces- sary system components, like low voltage disconnect, load resistor connection, 3 phase rectifyer. windMax250 Wind generator voltage Ugenmax=120Vac, Accu system voltage 12V/24V, Accu charging current 8A, IP40 with RS232 windMax500 Wind generator voltage Ugenmax=120Vac, Accu system voltage 12V/24/48V, Charging current 20A, IP65, optional with Display and RS232 windMax1000 Wind generator voltage Ugenmax=120Vac, Accu system voltage 12V/24/48V, Charging current 40A, IP55, optional with Display and RS232 windMax1500 Wind generator voltage Ugenmax=120Vac, Accu system voltage 12V/24/48V, Charging current 60A, IP54, optional with Display and RS232 windMax2000 Wind generator voltage Ugenmax=120Vac, Accu system voltage 12V/24/48V, Charging current 80A, IP54, optional with Display and RS232 windMax2500 Wind generator voltage Ugenmax=120Vac, Accu system voltage 12V/24/48V, Charging current 100A, IP54, optional with Display and RS232 MPP-Wind Power Controller Accu Wind Generator Load Resistor Total Discharge Protection DC-Converter and MPP- Controlling Dump Load Switch 3 Phase Rectifier Charge- Controlling Consumer windMax500 windMax250 Schams-Electronic GmbH PETER SCHWARZ Peter Schwarz Raiffeisenstr.4 D-92367 Pilsach Tel: 0049-(0)9181-405554 Fax: 0049-(0)9181-510456 Mobil: 0049-(0)177-3097686 Email: [email protected] Web: www.schams-solar.de

Upload: krissn7

Post on 13-Jun-2015

189 views

Category:

Documents


1 download

DESCRIPTION

Products that will improve 30% output of the solar panels and wind generators

TRANSCRIPT

Page 1: Schams solar Flyer MPPT-En

Our CompanyThe know-how of Schams-Electronic Ltd. is •based on more than 15 years of experience in the development of MPP Solar Charge Con-trollers and is state-of-the-art.

Our controllers are used worldwide, even in •the Antarctic.

Development with modern simulation pro-•grammes.

MPP-Charge ControllerWould you like to guarantee your customers an op-timum of solar power, not only during sunshine, but also during periods of bad weather, in winter and in summer while the accu is not overloaded and the wiring does not require great skills? In this case, you willfindourcontrollersverysuitable.

The Maximum Power Point controller (MPP) ensures maximumefficiencyofthesolarmoduleatalltimes.This may increase the charging rate up to 50%.

MPP-Charge Controllers for Wind Power Stations

More than 100% increase of charge current with •MPP Controllers, through optimized dimensioning of the wind generator station.Optimal adaptation of battery and wind generator •at varying windspeeds.Complete solution with the combination of all neces-•sary system components, like low voltage disconnect, load resistor connection, 3 phase rectifyer.

windMax250 Wind generator voltage Ugenmax=120Vac, Accu system voltage 12V/24V, Accu charging current 8A, IP40 with RS232

windMax500 Wind generator voltage Ugenmax=120Vac, Accu system voltage 12V/24/48V, Charging current 20A, IP65, optional with Display and RS232

windMax1000 Wind generator voltage Ugenmax=120Vac, Accu system voltage 12V/24/48V, Charging current 40A, IP55, optional with Display and RS232

windMax1500 Wind generator voltage Ugenmax=120Vac, Accu system voltage 12V/24/48V, Charging current 60A, IP54, optional with Display and RS232

windMax2000 Wind generator voltage Ugenmax=120Vac, Accu system voltage 12V/24/48V, Charging current 80A, IP54, optional with Display and RS232

windMax2500 Wind generator voltage Ugenmax=120Vac, Accu system voltage 12V/24/48V, Charging current 100A, IP54, optional with Display and RS232

MPP-Wind Power Controller

Accu

Wind Generator

Load ResistorTotal

Discharge Protection

DC-Converterand

MPP-Controlling

Dump Load Switch

3 PhaseRecti�er

Charge-Controlling

Consumer

windMax500

windMax250

Schams-Electronic GmbHPeter Schwarz

Peter SchwarzRaiffeisenstr.4D-92367 PilsachTel: 0049-(0)9181-405554Fax: 0049-(0)9181-510456Mobil: 0049-(0)177-3097686Email: [email protected]: www.schams-solar.de

Page 2: Schams solar Flyer MPPT-En

Additional Features of the Charge Controller

With our integrated DC-Converter it is possible •to transform solar voltage from 150V and wind generator voltage from 170V to a selectable bat-tery system voltage level.Due to our master-slave technique we can cus-•tomize the chargers. We offer controllers from 30W to 5kW.15 years of experience guarantee an optimal ben-•efitofyoursolar/windgenerator.

Benefits of our Charge Controller:Optimal adaptation of battery and solar module with •varying intensity of sunshineNodeficitwiththeinfluenceoftemperatureontheso-•lar cells, for example falling below the battery voltage when solar modules become too hot.Prevention of total discharge of the battery with •dynamic increase of the solar power at low battery voltage.Cabling with easy cable cross-sections, due to the pos-•sibility to choose higher solar voltage (up to 150V).Approximately 5 to 50% additional solar power •especially at times when it is most needed - during periods of bad weather and when the battery has been discharged.Easy handling and universal applications as for ex-•ample total discharge protection and dimmer as well as morning and evening timer for solar lighting all in one device.

Powergain via Accuvoltage

0

20

40

60

80

11.0 11.5 12.0 12.5 13.0 13.5 14.0

Ubat [V]

Ga

in [

%]

-10°C 0°C 20°C 50°C

This chart shows the increase of power gain through our MPP solar charge controllers with decreasing battery voltage. In addition, the diagram shows the influenceofthetemperatureofthesolarmodule.

Up to 50% More Solar Power through MPP-Controlling!

MPP-Solar Charge ControllerSMR100dt MPP-Solar Charge Controller for 12V accu

systems, accu charging current 8A, IP40 with Dimmer and 2 timers, Max. Solar voltage 25V

SMR250dt MPP-Solar Charge Controller for 12V and 24V accu systems, accu charging current 10A, IP40 with Dimmer and 2 timers, Max. Solar voltage 70V

SMR500 MPP-Solar Charge Controller for 12V/24V and 48V accu systems, 20A, IP65, optional with Display and RS232-Interface

SMR1000 MPP-Solar Charge Controller for 12V/24V and 48V accu systems, 40A, IP55, optional with Display and RS232-Interface

SMR1500 MPP-Solar Charge Controller for 12V/24V and 48V accu systems, 60A, IP54, optional with Display and RS232-Interface

SMR2000 MPP-Solar Charge Controller for 12V/24V and 48V accu systems, 80A, IP54, optional with Display and RS232-Interface

SMR2500 MPP-Solar Charge Controller for 12V/24V and 48V accu systems, 100A, IP54, optional with Display and RS232-Interface

SMR500 MPP Solar Charge Controller for 12V/24V and 48V

accu systems, 20A, IP65, optional with Display and RS232

SMR1000 MPP Solar Charge Controller for 12V/24V and

48V accu systems, 40A, IP55, optional with Display and

RS232-Interface

Accu

Consumer

Solar Module

DC-Converterand

MPP-Controlling

Dawn Switch

ChargeController

TotalDischargeProtection

Eveningand

Morning-timer

Accu

Consumer

Solar Module

Charge Controller and

BatteryManagement

TotalDischargeProtection

DC-Converterand

MPP-Controller

SMR250dt MPP Solar Charge Controller for 12V/24V accu systems, 10A, IP40

MPP Solar Charge Controller for Solar Lighting