scully scul-gard™ break-away cable - euromekanik · 2018-11-05 · scully scul-gard™ break-away...

1
Copyright © 2013 Scully Signal Company. Dynacheck, Dynamic Self-Checking, Dynamic Self-Testing, Faylsafe, IntelliCheck, Intellitrol are registered trademarks of Scully Signal Company. All Rights Reserved. Specifications are subject to change without notice. 60614BA Rev C June 2013 ORDERING INFORMATION Description Part Number TECHNICAL SPECIFICATIONS Scul-Gard Break-Away Cable DESCRIPTION Scully Signal's Scul-Gard TM Break-Away cables protect your existing investment in cables, wiring, and controllers while allowing you to recover from a drive-off in minutes without an electrician. Simply remove the remaining Scul-Gard TM adapter piece and reconnect using the existing original plug and cable. Designed for use as an extension for most Scully plug and cable assemblies, the Scul-Gard TM Break-Away cable is engineered to protect the primary cable, wiring, and controller from damage. The primary cable is minimally affected and can be reconnected immediately. The Scul-Gard TM Break-Away cable is intended to be the "weak link" in the cabling system.To assure that it performs as desired, it is very important that the existing cable and junction box be checked for proper installation before installing the Scul-Gard TM Break-Away cable. FEATURES AND BENEFITS The unique patent-pending design uses a new connector, which attaches directly to the existing Scully Plug and Cable. In the event a drive-off occurs, the break-away cable will be pulled from the socket and will break away in a controlled manner that protects the truck socket, cable assembly and rack controller. The sequential break-away cable will not separate at forces encountered during normal operation but will separate during drive-offs without damaging other components. If a drive-off occurs, the break-away cable is easily removed and replaced to restore operation using the existing standard cable. Fits most existing Scully Plug and Cable assemblies. Made from the same rugged, reliable and petroleum resistant components used in all Scully Plug and Cables. Uses existing wiring. Environmental Temperature: -40°F to +140°F (-40°C to +60°C) 10 Conductor Cable: White– 16 Guage All Other– 18 Guage 3 feet (91.44cm) Materials: Plug Body: Polyurethane Insulator: Polycarbonate Contact Pins: Stainless Steel The cables working length is enclosed in a fuel-resistant jacket. The cable is oil and gas resistant. 3 J slots 2 J slots 4 J slots Number of Pins Mating to J Slots on Sockets 3’ (91.44 cm) SG-GRN-4 Scul-Gard Break-Away Cable, 10 Pin, Green Plug, 4J Slots 09474 SG-GRN-2 Scul-Gard Break-Away Cable, 10 Pin, Green Plug, 2J Slots 09472 SG-BLU-3 Scul-Gard Break-Away Cable, 6 Pin, Blue Plug, 3J Slots 09473 Scully Scul-Gard™ Break-Away Cable For terminal equipment protection during truck drive-offs Featuring Dynacheck ® – Automatic and Continuous Self-Checking Circuitry Dynamic Self-Testing ® Overfill Prevention Systems Scully Signal Company 70 Industrial Way Wilmington, MA 01887, USA 800 272 8559 • [email protected] Scully Systems Europe NV Maanstraat 25 2800 Mechelen, Belgium +32 (0) 15 56 00 70 • [email protected] Scully UK Ltd Meridian House, Unit 33 37 Road One Winsford Industrial Estate, Winsford Cheshire CW7 3QG, UK +44 (0) 1606 553805 • [email protected]

Upload: others

Post on 17-Mar-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Scully Scul-Gard™ Break-Away Cable - Euromekanik · 2018-11-05 · Scully Scul-Gard™ Break-Away Cable For terminal equipment protection during truck drive-offs Featuring Dynacheck®

Copyright © 2013 Scully Signal Company. Dynacheck, Dynamic Self-Checking, Dynamic Self-Testing, Faylsafe, IntelliCheck, Intellitrolare registered trademarks of Scully Signal Company. All Rights Reserved. Speci�cations are subject to change without notice.

60614BA Rev C June 2013

ORDERING INFORMATIONDescription Part Number

TECHNICAL SPECIFICATIONS

Scul-Gard Break-Away Cable

DESCRIPTIONScully Signal's Scul-GardTM Break-Away cables protect your existing investmentin cables, wiring, and controllers while allowing you to recover from a drive-offin minutes without an electrician. Simply remove the remaining Scul-GardTM adapter piece and reconnect using the existing original plug and cable.

Designed for use as an extension formost Scully plug and cable assemblies,the Scul-GardTM Break-Away cableis engineered to protect the primarycable, wiring, and controller from damage.

The primary cable is minimally affected and can be reconnected immediately.

The Scul-GardTM Break-Away cable is intended to be the "weak link" in the cabling system.To assure that it performs as desired, it is very important that the existing cable and junction box be checked for proper installation before installing the Scul-GardTM Break-Away cable.

FEATURES AND BENEFITS

The unique patent-pending design uses a new connector, whichattaches directly to the existingScully Plug and Cable. In the eventa drive-off occurs, the break-away cable will be pulled from the socket and will break away in a controlled manner that protects the truck socket, cable assembly and rack controller.

The sequential break-away cable will not separate at forces encountered during normal operation but will separate during drive-offs without damaging other components.

If a drive-off occurs, the break-away cable is easily removed and replaced to restore operation using theexisting standard cable.

Fits most existing Scully Plug and Cable assemblies.

Made from the same rugged, reliable and petroleum resistant components used in all Scully Plug and Cables.

Uses existing wiring.

EnvironmentalTemperature: -40°F to +140°F (-40°C to +60°C)10 Conductor Cable: White– 16 Guage All Other– 18 Guage 3 feet (91.44cm)Materials:Plug Body: PolyurethaneInsulator: PolycarbonateContact Pins: Stainless SteelThe cables working length is enclosed in a fuel-resistant jacket. The cable is oil and gas resistant.

3 J slots2 J slots 4 J slots

Number of Pins Mating to J Slots on Sockets 3’(91.44 cm)

SG-GRN-4 Scul-Gard Break-Away Cable,10 Pin, Green Plug, 4J Slots 09474SG-GRN-2 Scul-Gard Break-Away Cable,10 Pin, Green Plug, 2J Slots 09472SG-BLU-3 Scul-Gard Break-Away Cable,6 Pin, Blue Plug, 3J Slots 09473

Scully Scul-Gard™ Break-Away CableFor terminal equipment protection during truck drive-offsFeaturing Dynacheck® – Automatic and Continuous Self-Checking Circuitry

Dynamic Self-Testing® Over�ll Prevention Systems

Scully Signal Company70 Industrial WayWilmington, MA 01887, USA800 272 8559 • [email protected]

Scully Systems Europe NVMaanstraat 252800 Mechelen, Belgium+32 (0) 15 56 00 70 • [email protected]

Scully UK LtdMeridian House, Unit 3337 Road One Winsford Industrial Estate,Winsford Cheshire CW7 3QG, UK+44 (0) 1606 553805 • [email protected]