september -2001 the dupline interface options dupline interface options
TRANSCRIPT
September -2001
The The Dupline Dupline Interface Interface OptionsOptions
Dupline Interface Options
September -2001
Family OverviewFamily Overview
Dupline Interface Options
Gateways to other Fieldbus Systems
Plug & Play PLC Links (Master Modules)
General-Purpose Links to PC/PLC Systems
Controllers with Built-in Communication Port (Master Generator)
General-purpose display interface (GTI 50)
September -2001
Fieldbus GatewaysFieldbus Gateways
Dupline Interface Options
Profibus-DP (Siemens ...)Profibus-DP (Siemens ...) (G3891 002X)(G3891 002X)DeviceNet (Allan Bradley)DeviceNet (Allan Bradley) (G3891 0050)(G3891 0050)Modbus - RTU Modbus - RTU (G3496 0005 & G38900014)(G3496 0005 & G38900014)Interbus / CAN / LON Interbus / CAN / LON (G3891 0050 Platform)(G3891 0050 Platform)
September -2001
Plug & Play PLC LinksPlug & Play PLC Links
Dupline Interface Options
• Lucky Goldstar - K-seriesLucky Goldstar - K-series (G3496 0001)(G3496 0001)• Ge Fanuc - Micro 90-30 seriesGe Fanuc - Micro 90-30 series (G3496 0002)(G3496 0002)• Mitsubishi - FX & AnS seriesMitsubishi - FX & AnS series (G3496 0003)(G3496 0003)• OMRON - CPM, CQM & C200OMRON - CPM, CQM & C200 (G3496 0004)(G3496 0004)• Allan Bradley - SLC5-0x & MicrologixAllan Bradley - SLC5-0x & Micrologix (G3496 0006)(G3496 0006)• Group Schneider - Telemechanique & ModiconGroup Schneider - Telemechanique & Modicon (G3496 0007)(G3496 0007)• Koyo – DL05 Micro FamilyKoyo – DL05 Micro Family (G3496 0008)(G3496 0008)• Matsushita – FP seriesMatsushita – FP series (G3496 0009)(G3496 0009)• Siemens Simatic – S7-200 FamilySiemens Simatic – S7-200 Family (G3496 0010)(G3496 0010)• ToshibaToshiba (G3496 0011)(G3496 0011)
September -2001
General-Purpose Links to PC / PLCGeneral-Purpose Links to PC / PLC
Dupline Interface Options
Master Module (Optolink protocol)Master Module (Optolink protocol) (G3496 0000)(G3496 0000) Optolink InterfaceOptolink Interface (G3491 0090)(G3491 0090) Modem InterfaceModem Interface (D9091 0210)(D9091 0210)
Note: Note:
A driver for one of the Dupline proprietary protocols must be implemented in the A driver for one of the Dupline proprietary protocols must be implemented in the actual Master unit based on the specifications and guidelines avaliable from Carlo actual Master unit based on the specifications and guidelines avaliable from Carlo Gavazzi.Gavazzi.
September -2001
Controller UnitsController Units
Dupline Interface Options
Master Generator (Modbus-RTU)Master Generator (Modbus-RTU) (G3890 0014)(G3890 0014) Monitoring ControllerMonitoring Controller (G3890 0034)(G3890 0034)
Note: Note:
If the G3890 0014 Generator is used in a multi-drop application, an external RS-232 to If the G3890 0014 Generator is used in a multi-drop application, an external RS-232 to RS-485 converter must be used.RS-485 converter must be used.
The G3890 0034 Controller unit uses a dedicated communication protocol which must The G3890 0034 Controller unit uses a dedicated communication protocol which must be adapted by the actual Master. be adapted by the actual Master.
September -2001
General-Purpose Display InterfaceGeneral-Purpose Display Interface
Dupline Interface Options
The compact GTI 50 Modbus – RTU Interface The compact GTI 50 Modbus – RTU Interface unit can be used with :unit can be used with :
Carlo Gavazzi Textdisplay Carlo Gavazzi Textdisplay (GTD 50)(GTD 50) ESA TouchscreenESA Touchscreen (GTS 565)(GTS 565) Proface TouchscreenProface Touchscreen (GTS377S)(GTS377S)
Note: Note:
The GTI 50 unit has no Channel Generator (Passive) and offers a RS-485 The GTI 50 unit has no Channel Generator (Passive) and offers a RS-485 communication port with Modbus protocol. (Id. Number can be set to 1 & 2).communication port with Modbus protocol. (Id. Number can be set to 1 & 2).
September -2001
Interface overviewInterface overview
Dupline Interface Options
DIGITAL ANALOG
Family CG Protocol Status Units Split I/O 1 - Bit 8-Bit 3½ BCD 3½ BCD Mux AnaLink In Out In Out In Out In Out In Out
Master-ModulesG3496 0000 Yes Optolink Slave 16 No 128 128 ( 16 ) ( 16 ) - - - - - -G3496 0001 Yes Goldstar Master 1 Select 128 128 ( 16 ) ( 16 ) - - - - - -G3496 0002 Yes GE-Fanuc Master 1 Select 128 128 ( 16 ) ( 16 ) - - - - - -G3496 0003 Yes Mitsubishi Master 1 Select 128 128 ( 16 ) ( 16 ) - - - - - -G3496 0004 Yes OMRON Master 1 Select 128 128 ( 16 ) ( 16 ) - - - - - -G3496 0005 Yes Modbus-RTU Slave 16 No 128 128 ( 16 ) ( 16 ) - - - - 32 -G3496 0006 Yes Allan Bradley Master 1 Select 128 128 ( 16 ) ( 16 ) - - - - - -G3496 0007 Yes Telemechanique Slave 1 Select 128 128 ( 16 ) ( 16 ) - - - - - -G3496 0008 Yes Koyo Master 1 Select 128 128 ( 16 ) ( 16 ) - - - - - -G3496 0009 Yes Matsushita Master 1 Select 128 128 ( 16 ) ( 16 ) - - - - - -G34960010 Yes Siemens Master 1 Select 128 128 ( 16 ) ( 16 ) - - - - - -
Gateways G3891 0020 Yes Profibus-DP Slave 98 Yes 128 128 ( 16 ) ( 16 ) ( 8 ) ( 8 ) 112 x 128 - G3891 0021 Yes Profibus-DP Slave 98 Yes 128 128 ( 16 ) ( 16 ) ( 8 ) ( 8 ) 64 64 128 - G3891 0120 No Profibus-DP Slave 98 Yes 128 128 ( 16 ) ( 16 ) ( 8 ) ( 8 ) 112 x - - G3891 0050 Yes DeviceNet Slave 63 Yes 128 128 ( 16 ) ( 16 ) ( 8 ) ( 8 ) 112 112 112 112
Controller´s G3890 0014 Yes Modbus, RTU Slave 16 Yes 128 128 ( 16 ) ( 16 ) ( 8 ) ( 8 ) x x 128 - G3890 0034 Yes Dedicated Slave 1 Yes 128 128 ( 16 ) ( 16 ) ( 8 ) ( 8 ) x x 112 -
Miscellaneous D9091 210 - Dedicated Slave 1 - 128 128 ( 16 ) ( 16 ) ( 8 ) ( 8 ) x x - -
G3491 0090 - Optolink Slave 63 - 128 128 ( 16 ) ( 16 ) ( 8 ) ( 8 ) x x - - GTI 50 - Modbus-RTU Slave 2 - 128 128 ( 16 ) ( 16 ) ( 8 ) ( 8 ) x x 128 -
September -2001
Remarks to the TableRemarks to the Table
Dupline Interface Options
The mentioned number of I/O´s The mentioned number of I/O´s isis the maximum of each type without the maximum of each type without regard regard for for the fact that Digital and Analog values share the samethe fact that Digital and Analog values share the same DuplineDupline adadddresses and canresses and can cause a conflict. This should be cause a conflict. This should be taken taken into considerationinto consideration when a when a system is designedsystem is designed..
September -2001
Interfacing Dupline to a PLC Through RS232/RS485Interfacing Dupline to a PLC Through RS232/RS485
Dupline Interface Options
Dupline NetworkDupline Serial/
Interface
PLCPLC
RS-232 / RS-485
September -2001
Interface to a PLC via Dupline Profibus-DP GatewayInterface to a PLC via Dupline Profibus-DP Gateway
Dupline Interface Options
PLCPLC
Pro
fib
us
-DP
Dupline Network 2
Dupline Network n
Dupline Network 1
Dupline® Profibus-DPGateway 2
Dupline® Profibus-DPGateway 1
Dupline® Profibus-DPGateway n
1
2
n
September -2001
Interfacing Dupline Networks to a PCInterfacing Dupline Networks to a PC
Dupline Interface Options
Dupline® Profibus-DPGateway 2
Dupline® network 2
Dupline® network n
Dupline® network 1
Pro
fib
us
-DP
Dupline® Profibus-DPGateway 1
Dupline® Profibus-DPGateway n
1
2
n
PCPCPCCard
PCCard