Site Master Model S114BQ Antenna, Cable, and Spectrum Analyzer User's Guide Hand-Held Tester for Transmission Lines and other RF Components

Upload: others

Post on 18-Feb-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

  • Site MasterModel S114BQ

    Antenna, Cable, andSpectrum Analyzer

    User's Guide

    Hand-Held Tester for Transmission Linesand other RF Components

  • WARRANTYThe Anritsu product(s) listed on the title page is (are) warranted against defects inmaterials and workmanship for one year from the date of shipment.Anritsu's obligation covers repairing or replacing products which prove to be defec-tive during the warranty period. Buyers shall prepay transportation charges forequipment returned to Anritsu for warranty repairs. Obligation is limited to the origi-nal purchaser. Anritsu is not liable for consequential damages.

    LIMITATION OF WARRANTYThe foregoing warranty does not apply to Anritsu connectors that have failed due tonormal wear. Also, the warranty does not apply to defects resulting from improper orinadequate maintenance by the Buyer, unauthorized modification or misuse, or op-eration outside the environmental specifications of the product. No other warranty isexpressed or implied, and the remedies provided herein are the Buyer's sole andexclusive remedies.

    TRADEMARK ACKNOWLEDGMENTSMS-DOS, Windows, Windows 95, Windows NT, and Windows 98 are registeredtrademarks of the Microsoft Corporation.Anritsu and Site Master are trademarks of Anritsu Company.

    NOTICEAnritsu Company has prepared this manual for use by Anritsu Company personneland customers as a guide for the proper installation, operation and maintenance ofAnritsu Company equipment and computer programs. The drawings, specifications,and information contained herein are the property of Anritsu Company, and any un-authorized use or disclosure of these drawings, specifications, and information isprohibited; they shall not be reproduced, copied, or used in whole or in part as thebasis for manufacture or sale of the equipment or software programs without theprior written consent of Anritsu Company.

    April 2000 10580-00040Copyright � 2000 Anritsu Co. Revision: A

  • Table of Contents

    Chapter 1 - General Information 1-1Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1Standard Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1Basic Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2Optional Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2Performance Specifications . . . . . . . . . . . . . . . . . . . . . . . . . 1-3Preventive Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7Annual Verification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7

    Chapter 2 - Getting Started 2-1Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1Charging a New Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1

    Charging the Battery in the Site Master . . . . . . . . . . . . . . . . . . . . . 2-1Charging the Battery in the Optional Charger . . . . . . . . . . . . . . . . . . 2-1

    Battery Charge Indicator . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2

    Discharging the NiMH Battery . . . . . . . . . . . . . . . . . . . . . . . 2-3

    Battery Life . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3

    Important Battery Information . . . . . . . . . . . . . . . . . . . . . . . 2-4

    Chapter 3 - Functions and Operations 3-1Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1Front Panel Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1Test Connector Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2Keypad Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3Soft Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6Power Monitor Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-22Printing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-23

    Printing a Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-23Printer Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-24

    Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-25Self Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-25Error Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-26

    Self Test Errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-26Range Errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-27

    Using the Soft Carrying Case. . . . . . . . . . . . . . . . . . . . . . . . 3-29

    i

  • Chapter 4 - Measurements 4-1Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1Measurement Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1Power On Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2

    Setting the Time/Date . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2

    Calibration Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3Selecting the Frequency Range . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3Performing a Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4Setting the Amplitude Scale . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4Saving the Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4Recalling a Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4Saving a Display to Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5Recalling a Display From Memory . . . . . . . . . . . . . . . . . . . . . . . . 4-5

    SWR (Return Loss) and Cable Loss Measurement . . . . . . . . . . . . 4-7Required Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7Device-Under-Test Specification. . . . . . . . . . . . . . . . . . . . . . . . . . 4-7Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7Selecting the Measurement Mode . . . . . . . . . . . . . . . . . . . . . . . . . 4-7Selecting the Frequency Range . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7Performing a Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8SWR or Return Loss Measurement . . . . . . . . . . . . . . . . . . . . . . . . 4-9Set the Amplitude Scale and Limit Line . . . . . . . . . . . . . . . . . . . . . 4-9Setting the Markers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10

    Cable Loss Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11Setting the Amplitude Scale . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11Setting the Markers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11

    DTF Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-13Required Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-13Device-Under-Test Specification . . . . . . . . . . . . . . . . . . . . . . . . . 4-13Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-13Selecting the Measurement Mode . . . . . . . . . . . . . . . . . . . . . . . . 4-13Performing a Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-14DTF Measurement (Determining the Length of the Cable) . . . . . . . . . . 4-15Setting the Amplitude Scale . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-15Setting the Marker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-15DTF Measurement (Determining the quality of the cable) . . . . . . . . . . . 4-17Setting the Amplitude Scale . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-17Setting the Markers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-17

    Spectrum Analyzer Measurements . . . . . . . . . . . . . . . . . . . . 4-19Selecting the Measurement Mode . . . . . . . . . . . . . . . . . . . . . . . . 4-19Setting the Frequency Range . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-19Setting the Resolution and Video Bandwidths (RBW & VBW) . . . . . . . . 4-19Setting the Reference Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-20Setting the marker. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-20Setting the frequency span . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-20

    Making Power Measurements . . . . . . . . . . . . . . . . . . . . . . . 4-22Entering Power Monitor Mode. . . . . . . . . . . . . . . . . . . . . . . . . . 4-22Zeroing the Power Monitor. . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-22Measuring High Input Power Levels. . . . . . . . . . . . . . . . . . . . . . . 4-22Displaying Power in dBm and Watts . . . . . . . . . . . . . . . . . . . . . . 4-22Displaying Relative Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-22

    ii

  • Chapter 5 - Software Tools Program 5-1Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1Communication Port Setting. . . . . . . . . . . . . . . . . . . . . . . . . 5-1Changing COM Port Settings–Windows 95/98/NT . . . . . . . . . . . . 5-1Software Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3Plot Capture. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3

    Capture multiple traces to a database. . . . . . . . . . . . . . . . . . . . . . . 5-4Capture single or multiple traces to PC screen . . . . . . . . . . . . . . . . . . 5-4

    Custom Cable List Uploading andDownloading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-5

    Uploading a Cable List to the Site Master Custom Cable Table . . . . . . . . 5-5Downloading a Cable List from the Site Master Custom Cable Table . . . . . 5-5Saving a Custom Cable List . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-5

    Program Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6Fault Location Software . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6Smith Chart Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6Saving a Plot as a Windows Metafile or as a Spreadsheet File . . . . . . 5-7Pasting a Plot in Graphic or SpreadsheetFormat. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-7Saving Data to a Database . . . . . . . . . . . . . . . . . . . . . . . . . . 5-7“Drag-n-Drop” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-7Printing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-8

    Appendix A - Reference Data A-1Coaxial Cable Technical Data. . . . . . . . . . . . . . . . . . . . . . . . A-1

    iii/iv

  • Chapter 1General Information

    IntroductionThis chapter provides a description, performance specifications, optional accessories, pre-ventive maintenance, and calibration requirements for the Site Master model S114BQ.Throughout this manual, the term Site Master will refer only to the model S114BQ.

    Model Frequency RangeS114BQ 2 to 1000 MHz, 100 kHz to 1200 MHz Spectrum Analysis

    DescriptionThe Site Master is a sythesizer-based hand held SWR/RL (standing wave ratio/return loss),Distance-To- Fault (DTF) and spectrum analysis measurement instrument. The S114BQhas a keypad to enter data and a liquid crystal display (LCD) to provide graphic indicationsof SWR or RL over the selected frequency range and selected distance. The Site Master iscapable of up to 2.5 hours of continuous operation from a fully charged field-replaceablebattery and can be operated from a 12.5 dc source. Built-in energy conservation featurescan be used to extend battery life over an eight-hour work day.

    The Site Master is designed for measuring SWR, return loss, or cable insertion loss, locat-ing faulty RF components in antenna systems, and spectrum analysis. Power monitoring isavailable as an option. The displayed trace can be scaled or enhanced with frequency mark-ers or a limit line. A menu option provides for an audible “beep” when the limit value is ex-ceeded. To permit use in low-light environments, the LCD can be back lit using a frontpanel key.

    Standard AccessoriesThe Software Tools PC-based software program provides a database record for storingmeasurement data. Site Master Software Tools can also convert the Site Master display to aMicrosoft Windows� 95/98/NT workstation graphic. Measurements stored in the Site Mas-ter internal memory can be downloaded to the PC using the included null-modem serial ca-ble. Once stored, the graphic trace can be displayed, scaled, or enhanced with markers andlimit lines. Historical graphs can be overlaid with current data, and underlying data can beextracted and used in spreadsheets or for other analytical tasks.

    The Site Master Software Tools program also performs DTF (Distance To Fault) and FaultLocation.

    1 - 1

    1

  • Basic ConfigurationThe S114BQ is packaged with the following items:

    � Soft Carrying Case

    � AC-DC Adapter

    � Automotive Cigarette Lighter 12 Volt DC Adapter,

    � CDROM disk containing the Software Tools program. This program contains Fault Lo-cation (DTF) and Smith Chart functions.

    � Serial Interface Cable (null modem type)

    � One year Warranty (includes battery, firmware, and software)

    � User's Guide

    � Option 5 — RF Wattmeter Power Monitor

    � RF Detector, 1 to 3000 MHz, N(m) input connector, 50 Ohms, Part No. 5400-71N50

    � Anritsu Precision N (f) Open/Short/Load, 42 dB, Part No. OSLNF50LF

    � Armored Test Port Extension Cable, 3.0 meter, N (m) toN (f), Part No. 15NNF50-3.0A

    � Transit Case for Site Master, Part No. 760-215A

    Optional Accessories� Anritsu Precision N (m) Open/Short/Load, 42 dB, Part No. OSLN50LF

    � Anritsu Precision N (m) Short/Open, Part No. 22N50

    � Anritsu Precision N (f) Short/Open, Part No. 22NF50

    � Site Master Precision N (m) Load, 42 dB, Part No. SM/PL

    � Site Master Precision N (f) Load, 42 dB, Part No. SM/PLNF

    � 7/16 (m) Precision Open/Short/Load, Part No. 2000-767

    � 7/16 (f) Precision Open/Short/Load, Part No. 2000-768

    � Adapter, Precision N (m) to N (m), Part No. 34NN50A

    � Adapter, Precision N (f) to N (f), Part No. 34NFNF50

    � Adapter, 7/16 (f) to N (m), Part No. 510-90

    � Adapter, 7/16 (f) to N (f), Part No. 510-91

    � Adapter, 7/16 (m) to N (m), Part No. 510-92

    � Adapter, 7/16 (m) to N (f), Part No. 510-93

    � Adapter, 7/16 DIN (m) to 7/16 DIN (m), Part No. 510-96

    � Adapter, 7/16 DIN (f) to 7/16 DIN (f), Part No. 510-97

    � Armored Test Port Extension Cable, 1.5 meter, N (m) toN (f), Part No. 15NNF50-1.5A

    1 - 2

    Chapter 1 General Information

  • � Armored Test Port Extension Cable, 5.0 meter, N (m) toN (f), Part No. 15NNF50-5.0A

    � Armored Test Port Extension Cable, 1.5 meter, N (m) toN (m), Part No. 15NN50-1.5A

    � Armored Test Port Extension Cable, 3.0 meter, N (m) toN (m), Part No. 15NN50-3.0A

    � Armored Test Port Extension Cable, 5.0 meter, N (m) toN (m), Part No. 15NN50-5.0A

    � Armored Test Port Extension Cable, 1.5 meter, N (m) to7/16 DIN (f), Part No. 15NDF50-1.5A

    � Armored Test Port Extension Cable, 1.5 meter, N (m) to7/16 DIN (m), Part No. 15ND50-1.5A

    � Antenna SMA (f), 50� 806 - 869 MHz, Part No. 2000-1034

    � Antenna SMA (m), 50� 902 - 960 MHz, Part No. 2000-1035

    � HP Deskjet 340 Printer, Part No. 2000-766

    � Serial-to-Parallel Converter Cable (use with the HP 340 Printer), Part No. 2000-753

    � Seiko DPU-414 Thermal Printer, Part No. 2000-754 (U.S.) or2000-761 (Europe)

    � US Adapter (use with the DPU-414 Printer),Part No. 2000-1002

    � Europe Adapter (use with the DPU-414 Printer)Part No. 2000-1003

    � Battery Pack (use with the DPU-414 Printer)Part No. 2000-1004

    � Serial Interface Cable (use with the DPU-414 Printer),Part No. 2000-10012

    � Thermal Paper (use with the DPU-411/DPU-414 Printer),Part No. 2000-755

    � Rechargeable Battery, NiMHPart No. 633-27

    � Battery Charger, NiMH onlyPart No. 2000-1029

    Performance SpecificationsPerformance specifications are provided in Table 1-1, on the following page.

    1 - 3

    Chapter 1 General Information

  • 1 - 4

    Chapter 1 General Information

    Specifications are valid when the unit is calibrated at ambient temperature after a 5 minutewarmup.

    Description ValueSite Master: Frequency Range:S114BQ 2 to 1000 MHz

    Frequency Accuracy (CW Mode): 75 parts per million @ 25°C*

    Frequency Resolution: 10 kHz

    SWR:RangeResolution

    1.00 to 65.000.01

    Return Loss:RangeResolution

    0.00 to 54.00 dB0.01 dB

    **Distance-To-Fault (DTF):Range (in meters)Resolution (in meters)(Rectangular Windowing)

    0 to (Resolution x dp)( . )( )1 5 108� Vf

    F�

    Where Vf is the relative propagation velocity ofthe cable .dp is the number of data points (128, 256,512).�F is F2 - F1 (in Hz)

    Wattmeter Power Monitor:Range

    Offset RangeResolution

    –80.0 to +80 dBm or10.0 pW to 100.0 kW0 to +60.0 dB0.1 dB or0.1 xW

    RF Detector Range –50 dBm to + 20 dBm10.0 �W to +100.0 mW

    Test Port, Type N 50 Ohms

    ***Immunity to Interfering signalsup to the level of: +10 dBm, RF Out/Reflection

    Maximum Input (Damage Level):Test Port, Type NRF Detector

    +22 dBm+20 dBm

    Measurement Accuracy: Measurement accuracy depends on calibrationcomponents. Precision calibration componentshave a directivity of 42 dB.

    Cable Insertion Loss:RangeResolution

    0.00 to 54.00 dB0.01 dB

    Spectrum Analyzer:Frequency Range 100 kHz to 1200 MHz

    Frequency ReferenceAgingAccuracy

    ±1 ppm/yr±2 ppm

    Frequency Span 0 Hz (zero span) 100 kHz to 1200 MHz

    Sweep Time 0.5 sec. typical

    Table 1-1. Performance Specifications (1 of 2)

  • 1 - 5

    Chapter 1 General Information

    Resolution Bandwidth(-3 dB width)

    10 kHz, 30 kHz, 100 kHz, 1 MHz ,+/- 20%

    Video Bandwidth(Range –3 dB) 3 kHz, 10 kHz, 30 kHz and 300 kHz

    SSB Phase Noise@ (1 GHz) 30 kHz offset � –74 dBc/Hz

    Spurious ResponsesInput Related � –45 dBc

    SpuriousResidual Responses � –80 dBm

    Note: 10 kHz resolution bandwidth, input termi-nated, no attenuation

    AmplitudeMeasurement RangeDynamic RangeMaximum Safe Input Level

    –90 dBm to +20 dBm 60 dB+20 dBm, maximum measurable safe input+27 dBm, maximum damage+27 dBm, peak pulse power+50 Vdc

    Displayed Average NoiseLevel: � –90 dBm (400 kHz span)

    Display RangeLog Scale 2 to 15 dB/div. In 1 dB steps. Ten divisions dis-

    played.

    Frequency Response

    RF Input VSWR � 2.0:1

    Resolution (Ref. Level) 1.0 dB

    Total Level Accuracy ±2.0 dB

    GeneralInternal Memory:

    Trace MemoryInstrument config.

    RS-232 Interface:

    200 maximum10 setup locations9 pin D-sub, three wire serial

    Electromagnetic Compatibility Meets European community requirements forCE marking

    Power Supply:External DC Input +12.5 to +15 Vdc, 1100 mA max.

    Temperature:StorageOperation

    –20° C to 75° C0° C to 50° C

    Weight: 1.82 kg (4.0 pounds)

    Dimensions: 25.4 x 17.8 x 6.1 cm(10 x 7 x 2.4 inches)

    * ±2 ppm/�°C from 25°C** Fault location is accomplished by inverse Fourier Transformation of data taken with the Site Master. Resolution andmaximum range depend on the number of frequency data points, frequency sweep range and relative propagation veloc-ity of the cable being tested.*** Immunity measurement is made in CW mode with incoming interfering signal exactly at the same frequency (worstcase situation). Typical immunity is better when swept frequency is used.

    Table 1-2. Performance Specifications (2 of 2)

  • Preventive MaintenanceSite Master preventive maintenance consists of cleaning the unit and inspecting and clean-ing the RF connectors on the instrument and all accessories.

    Clean the Site Master with a soft, lint-free cloth dampened with water or water and a mildcleaning solution.

    CAUTION: To avoid damaging the display or case, do not use solvents or abra-sive cleaners.

    Clean the RF connectors and center pins with a cotton swab dampened with denatured alco-hol. Visually inspect the connectors. The fingers of the N (f) connectors and the pins of theN (m) connectors should be unbroken and uniform in appearance. If you are unsure whetherthe connectors are good, gauge the connectors to confirm that the dimensions are correct.

    Visually inspect the test port cable(s). The test port cable should be uniform in appearance,not stretched, kinked, dented, or broken.

    1 - 6

    Chapter 1 General Information

  • CalibrationThe Site Master is a field portable unit operating in the rigors of the test environment. AnOpen-Short-Load (OSL) calibration should be performed prior to making a SWR/RL mea-surement in the field. A built-in temperature sensor in the Site Master advises the user, viaan icon located on the right side of the LCD screen, that the internal temperature has ex-ceeded a safety window, and the user is advised to perform another OSL calibration in or-der to maintain the integrity of the measurement.

    NOTES:For best calibration results—compensation for all measurement uncertain-ties—ensure that the Open/ Short/Load is at the end of the test port or optionalextension cable; that is, at the same point that you will connect the antenna ordevice to be tested.

    For best results, use a phase stable Test Port Extension Cable (see OptionalAccessories). If you use a typical laboratory cable to extend the Site Master testport to the device under test, cable bending subsequent to the OSL calibrationwill cause uncompensated phase reflections inside the cable. Cables which arenot phase stable may cause measurement errors that become more pro-nounced as the test frequency increases.

    For optimum calibration, Anritsu recommends using precision calibration components.

    The Site Master S114BQ performs a spectrum analysis calibration during start-up. Spec-trum analysis calibration is not required prior to making a spectrum analysis measurement.

    Annual VerificationAnritsu recommends an annual calibration and performance verification of the Site Masterand the OSL calibration components by local Anritsu service centers. Anritsu service cen-ters are listed in Table 1-2 on the following page.

    The Site Master itself is self-calibrating, meaning that there are no field-adjustable compo-nents. However, the OSL calibration components are crucial to the integrity of the calibra-tion and therefore, must be verified periodically to ensure performance conformity. This isespecially important if the OSL calibration components have been accidentally dropped orover-torqued.

    1 - 7

    Chapter 1 General Information

  • 1 - 8

    Chapter 1 General Information

    UNITED STATESANRITSU COMPANY

    685 Jarvis Drive

    Morgan Hill, CA 95037-2809

    Telephone: (408) 776-8300,

    1-800-ANRITSU

    FAX: 408-776-1744

    ANRITSU COMPANY

    10 New Maple Ave., Unit 305

    Pine Brook, NJ 07058

    Telephone: (201) 227-8999,

    1-800-ANRITSU

    FAX: 201-575-0092

    ANRITSU COMPANY

    1155 E. Collins Blvd

    Richardson, TX 75081

    Telephone: 1-800-ANRITSU

    FAX: 972-671-1877

    AUSTRALIAANRITSU PTY. LTD.

    Unit 3, 170 Foster Road

    Mt. Waverley, VIC 3149

    Australia

    Telephone: 03-9558-8177

    Fax: 03-9558-8255

    BRAZILANRITSU ELECTRONICA LTDA.

    Praia de Botafogo 440, Sala 2401

    CEP 22250-040,Rio de Janeiro,RJ,

    Brasil

    Telephone: 021-28-69-141

    Fax: 021-53-71-456

    CANADAANRITSU INSTRUMENTS LTD.

    215 Stafford Road, Unit 102

    Nepean, Ontario K2H 9C1

    Telephone: (613) 828-4090

    FAX: (613) 828-5400

    CHINAANRITSU BEIJING SERVICE CENTER

    Beijing Fortune Building

    416W, 5 Dong San Huan Bei Lu

    Chaoyang qu

    Beijing 100004, China

    Telephone: 011065909237

    FAX: 011065909236

    FRANCEANRITSU S.A

    9 Avenue du Quebec

    Zone de Courtaboeuf

    91951 Les Ulis Cedex

    Telephone: 016-44-66-546

    FAX: 016-44-61-065

    GERMANYANRITSU GmbH

    Grafenberger Allee 54-56

    D-40237 Dusseldorf, Germany

    Telephone: 0211-96 85 50

    FAX: 0211-96 85 555

    INDIAMEERA AGENCIES (P) LTD

    A-23 Hauz Khas

    New Delhi 110 016

    Telephone: 011-685-3959

    FAX: 011-686-6720

    ISRAELTECH-CENT, LTD

    Haarad St. No. 7, Ramat Haahayal

    Tel-Aviv 69701

    Telephone: (03) 64-78-563

    FAX: (03) 64-78-334

    ITALYANRITSU Sp.A

    Rome Office

    Via E. Vittorini, 129

    00144 Roma EUR

    Telephone: (06) 50-22-666

    FAX: (06) 50-22-4252

    JAPANANRITSU CORPORATION

    1800 Onna Atsugi-shi

    Kanagawa-Prf. 243 Japan

    Telephone: 0462-23-1111

    FAX: 0462-25-8379

    KOREAANRITSU CORPORATION LTD.

    #901 Daeo Bldg. 26-5

    Yeoido Dong, Youngdeungpo

    Seoul Korea 150 010

    Telephone: 02-782-7156

    FAX: 02-782-4590

    SINGAPOREANRITSU (SINGAPORE) PTE LTD

    3 Shenton Way #24-03

    Shenton House

    Singapore 0106

    Telephone: 022-65-206

    FAX: 022-65-207

    SOUTH AFRICAETESCSA

    12 Surrey Square Office Park

    330 Surrey Avenue

    Ferndale, Randburt, 2194

    South Africa

    Telephone:01-11-787-7200

    Fax: 01-11-787-0446

    SWEDENANRITSU AB

    Botvid Center

    S-1585

    Stockholm, Sweden

    Telephone: (08) 534-717-00

    FAX: (08) 534-717-30

    TAIWANANRITSU CO., LTD.

    8F, No. 96, Section 3

    Chien Kuo N. Road

    Taipei, Taiwan, R.O.C.

    Telephone: (02) 515-6050

    FAX: (02) 509-5519

    UNITED KINGDOMANRITSU LTD.

    200 Capability Green

    Luton, Bedfordshire

    LU1 3LU, England

    Telephone: 015-82-41-88-53

    FAX: 015-82-31-303

    Table 1-2. Anritsu Service Centers

  • Chapter 2Getting Started

    IntroductionThe Nickel Metal Hydride (NiMH) Battery supplied with the Site Master is shipped in adischarged state. Before using the Site Master, the internal battery must first be charged forthree hours, either in the Site Master or in the optional battery charger (Anritsu part num-ber: 2000-1029).

    Charging a New BatteryNew batteries normally require three to five charge and discharge cycles before attainingmaximum performance. The NiMH battery supplied with the Site Master has already com-pleted three charge and discharge cycles at the factory and full battery performance shouldbe realized after your first charge.

    Charging the Battery in the Site Master

    The battery can be charged while still installed in the Site Master.

    Step 1. Turn the Site Master off.

    Step 2. Connect the AC-DC adapter (Anritsu part number: 40-115) to the Site Mastercharging port.

    Step 3. Connect the AC adapter to a 120 VAC or 240 VAC power source as appropriatefor your application.

    The green external power indicator on the Site Master will illuminate, indicatingthe presence of external DC power and the battery will begin charging. The indi-cator will remain lit as long as the battery is charging. Once the battery is fullycharged, the battery indicator will turn off. If the battery fails to charge, contactyour nearest Anritsu service center.

    Charging the Battery in the Optional Charger

    Up to two batteries can be charged simultaneously in the optional battery charger.

    Step 1. Remove the NiMH battery from your Site Master and place it in the optionalcharger (Anritsu part number: 2000-1029).

    Step 2. Connect the lead from the AC-DC adapter to the charger.

    Step 3. Connect the AC-DC adapter to a 120 VAC or 240 VAC power source as appro-priate for your application.

    Each battery holder in the optional charger has an LED charging status indicator. The LEDcolor changes as the battery is charged:

    Red indicates the battery is chargingGreen indicates the battery is fully chargedYellow indicates the battery is in a waiting state (see below).

    2 - 1

    2

  • A yellow light may occur because the battery became too warm during the charge cycle.The charger will allow the battery to cool off before continuing the charge. A yellow lightmay also indicate that the charger is alternating charge to each of the two batteries.

    A blinking red light indicates less than 13 VDC is being supplied to the charger stand.Check that the correct AC charger adapter is connected to the charger stand.

    If a battery fails to charge, contact your nearest Anritsu Service Center.

    You can charge the battery anytime. However, NiMH battery will last longer and performbetter if allowed to completely discharge before recharging. For maximum battery life, it isrecommended that the NiMH battery be completely discharged and recharged once everythree months.

    Battery Charge IndicatorWhen the AC-DC adapter is unplugged from the Site Master, the battery indicator symbolwill be continuously displayed at the top left corner of the Site Master display (Figure 2-1).

    A totally black bar indicates a fully charged battery. When LOW BATT replaces the bat-tery indicator bar at the top left corner, a couple of minutes of measurement time remains. Ifa flashing LOW BATT is accompanied by an audio beep at the end of each trace, the bat-tery has approximately one minute of useable time remaining.

    2 - 2

    Chapter 2 Getting Started

    Battery Indicator

    Figure 2-1. Site Master Battery Indicator

  • The battery status can also be checked by pressing the SYS key and the STATUS soft key.The Status table will display the remaining battery charge as a percent, as shown below.

    Once all the power has drained from the battery, the Site Master display will fade. At thispoint, your Site Master will switch itself off and the battery will need to be recharged.

    Discharging the NiMH BatteryThe NiMH battery will last longer and perform better if allowed to completely dischargebefore recharging. For maximum battery life, it is recommended that the NiMH battery becompletely discharged and recharged once every three months.

    To discharge the battery, leave the Site Master switched on until the battery is drained. TheSite Master will display a LOW BATT message and an audio warning when the battery be-gins to run low. Allow the battery to fully discharge until the Site Master switches itself off.

    NOTE:Do not attempt to discharge the battery by any other means. Never short-circuitthe battery terminals.

    Battery LifeIt is normal for NiMH batteries to self-discharge during storage. To minimize battery dis-charge during storage, it is recommended that the battery be removed from the Site Masterif the Site Master is not to be used for a long period of time.

    It is normal for NiMH battery to degrade to 80% of original capacity after 12 months ofcontinuous use.

    The battery can be charged and discharged 300 to 500 times, but it will eventually wear out.The battery may need to be replaced when the operating time between charging is notice-ably shorter than normal.

    2 - 3

    Chapter 2 Getting Started

    STATUS

    OSL CALIBRATIONFREQUENCY = 2.0 – 1000 MHzCAL TEMPERATURE (24–54 C)

    CURRENT TEMPERATURE = 38 C

    BATTERY CHARGE = 75%

    PRESS ESCAPE TO CONTINUE

    Figure 2-2. Example Status Table Display

  • Important Battery Information� With a new NiMH battery, full performance is achieved after three to five complete

    charge and discharge cycles.

    � Use only Anritsu approved battery packs.

    � Recharge the battery only in the Site Master or in an Anritsu approved charger.

    � When the Site Master or the charger is not in use, disconnect it from the power source.

    � Do not charge batteries for longer than 24 hours; overcharging may shorten battery life.

    � If left unused a fully charged battery will discharge itself over time.

    � Discharge an NiMH battery from time to time to improve battery performance and bat-tery life.

    � The battery can be charged and discharged hundreds of times, but it will eventually wearout.

    � The battery may need to be replaced when the operating time between charging is notice-ably shorter than normal.

    � Do not short-circuit the battery terminals.

    � Do not drop, mutilate or attempt to disassemble the battery.

    � Never use a damaged or worn out charger or battery.

    � Always use the battery for its intended purpose only.

    � Temperature extremes will affect the ability of the battery to charge: allow the battery tocool down or warm up as necessary before use or charging.

    � Storing the battery in extreme hot or cold places will reduce the capacity and lifetime ofthe battery.

    � Do not dispose of batteries in a fire!

    � Batteries must be recycled or disposed of properly. Do not place batteries in garbage.

    2 - 4

    Chapter 2 Getting Started

  • Chapter 3Functions and Operations

    IntroductionThis chapter provides a brief overview of the Site Master functions and operations, provid-ing the user with a starting point for making basic measurements. For more detailed infor-mation, refer to Chapter 4, Measurements and Chapter 5, Software Tools.

    The Site Master is designed specifically for field environments and applications requiringmobility. As such, it is a lightweight, handheld, battery operated unit which can be easilycarried to any location, and is capable of up to 2.5 hours of continuous operation from afully charged battery. Built-in energy conservation features allow battery life to be extendedover an eight-hour workday. The Site Master can also be powered by a 12.5 Vdc externalsource. The external source can be either the Anritsu AC-DC Adapter (P/N 40-115) or 12.5Vdc Automotive Cigarette Lighter Adapter (P/N 806-62). Both items are standard accesso-ries.

    Front Panel OverviewThe Site Master menu-driven user interface is easy to use and requires little training. Mode,Frequency, Amplitude and Sweep function keys are located just below the display and areeasily configured for optimum measurements. Selection of one of these keys brings up afunction-specific menu on the right hand side of the display. The softkeys adjacent to thedisplay provide access to the various menu items (See Figure 3-1).

    3-1

    HOLDRUN

    STARTCAL

    AUTOSCALE

    SAVESETUP

    RECALLSETUP

    LIMIT MARKER

    SAVEDISPLAY

    RECALLDISPLAY

    PRINT

    MODE FREQ/DIST AMPLITUDE SWEEP

    SYS

    ENTER

    CLEAR

    ESCAPE

    ONOFF

    /

    1 2

    4

    5 6

    7 8

    9 0

    3

    +-

    .

    SOFT KEYS

    Site Master S114BQ

    2.00

    791.12 MHz

    400.43 MHz

    1000.00

    Figure 3-1. Site Master Soft Keys

    3

  • Test Connector PanelThe connectors and indicators located on the test panel are listed and described below.

    12.5-15VDC(1100 mA)

    12.5 to 15 Vdc @ 1100 mA input to power the unit or for battery charging.

    WARNING

    When using the AC-DC Adapter, always use a three-wire power cable connectedto a three-wire power line outlet. If power is supplied without grounding the equip-ment in this manner, there is a risk of receiving a severe or fatal electric shock.

    BatteryCharging

    Illuminates when the battery is being charged. The indicator automatically shutsoff when the battery is fully charged.

    ExternalPower

    Illuminates when the Site Master is being powered by the external charging unit.

    SerialInterface

    RS232 DB9 interface to a COM port on a personal computer (for use with theAnritsu Software Tools program) or to a supported printer.

    RF In RF input, 50 � impedance, for spectrum analysis measurements.

    RF Out RF output, 50 � impedance, for reflection measurements.

    RF Detector RF detector input for the Power Monitor.

    3-2

    Chapter 3 Functions and Operations

  • Keypad ControlsThis section contains an alphabetical listing of the Site Master front panel keypad controlsalong with a brief description of each. More detailed descriptions of the major functionkeys follow.

    Turns the liquid crystal display (LCD) back-lighting ON or OFF. (Leaving backlighting off conserves battery power.)

    LCD Contrast adjust. Use the Up/Down arrow key and ENTER to adjust the dis-play contrast.

    AMPLITUDE Displays the amplitude or scale menu of the current operating mode.

    NOTE:The AMPLITUDE and LIMIT keys are functionally identical.

    AUTOSCALE

    Automatically scales the display for optimum resolution.

    ENTER Implements certain menu and key selections.

    ESCAPECLEAR

    Exits the present operation or clears the display. If a parameter is being edited,pressing this key will clear the value currently being entered and restore the lastvalid entry. Pressing this key again will close the parameter. During normalsweeping, pressing this key will move up one menu level.

    FREQ/DIST Displays the Frequency or Distance menu depending on the measurement mode.

    LIMIT Displays the amplitude or scale menu of the current operating mode.

    MARKER Displays the marker menu of the current operating mode.

    MODE Opens the mode selection box (below). Use the Up/Down arrow key to select amode. Press the ENTER key to implement.

    3-3

    Chapter 3 Functions and Operations

    MEASUREMENT MODE

    FREQ - SWR

    RETURN LOSS

    CABLE LOSS - ONE PORT

    DTF - SWR

    RETURN LOSS

    POWER MONITOR

    SPECTRUM ANALYZER

    Figure 3-2. Mode Selection Box

  • ONOFF

    Turns the Site Master on or off. When turned on, the system state at the lastturn-off is restored. If the ESCAPE/CLEAR key is held down, the factory presetstate is restored.

    PRINT Prints the current display to the selected printer via the RS232 serial port.

    RECALLDISPLAY

    Recalls a previously saved trace from memory. When the key is pressed, a Re-call Trace selection box appears on the display. Select a trace using theUp/Down arrow key and press the ENTER key to implement.

    To erase a saved trace, highlight the trace and select the DELETE TRACEsoftkey. To erase all saved traces, select the DELETE ALL TRACES softkey.

    RECALLSETUP

    Recalls a previously saved setup from memory location 1 through 10. When thekey is pressed, a RECALL SETUP selection box appears on the display. Select asetup using the Up/Down arrow key and press the ENTER key to implement.Setup 0 recalls the factory preset state.

    RUNHOLD

    When in the Hold mode, this key starts the Site Master sweeping and provides aSingle Sweep Mode trigger; when in the Run mode, it pauses the sweep. Whenin the Hold mode, the hold symbol (page 3-25) appears on the LCD. Hold modeconserves battery power.

    SAVEDISPLAY

    Saves up to 200 displayed traces to non-volatile memory. When the key ispressed, TRACE NAME: appears in the lower left of the display. Save the dis-play with up to 16 alphanumeric characters for that trace name and press theENTER key to implement.

    SAVESETUP

    Saves the current system setup to 1 of 10 internal non-volatile memory loca-tions. When the key is pressed, a SAVE SETUP selection box appears on the dis-play. Use the Up/Down arrow key to select a setup and press the ENTER key toimplement.

    STARTCAL

    Starts the calibration in SWR, Return Loss, Cable Loss, or DTF measurementmodes. Follow the text in the lower left message area that instructs you to do thefollowing:

    � CONNECT OPEN TO RF out PORT, Press ENTERThe Site Master then measures the calibration “open” that you must attach tothe end of the test port or transmission line.

    � CONNECT SHORT TO RF out PORT, Press ENTERThe Site Master then measures the calibration “short” that you must attach tothe end of the test port or transmission line.

    � CONNECT LOAD TO RF out PORT, Press ENTERThe Site Master then measures the 50� load that you must attach to the endof the test port or transmission line.

    NOTE:The combined measurements of an open, a short, and a known-impedanceload normalizes the measurement system to account for uncertainties intro-duced by measurement-system components (e.g., cables, connectors, etc.).

    3-4

    Chapter 3 Functions and Operations

  • SWEEP Displays the Sweep function soft key menu for the current operating mode.

    SYS Displays the System menu softkey selections.

    Up/DownArrow Key

    Increments or decrements a parameter value or chooses an item from a listwhich can then be selected with the ENTER key.

    NOTE:At turn on, before any other keys are pressed, the Up/Down arrow key may beused to adjust display contrast.

    3-5

    Chapter 3 Functions and Operations

  • Soft KeysEach keypad key opens a set of soft key selections. Each of the soft keys has a correspond-ing soft key label area on the display. The label identifies the function of the soft key for thecurrent Mode selection.

    NOTE:The AMPLITUDE and LIMIT keys are functionally identical.

    Figures 3-3 through 3-8 show the soft key labels for each Mode selection.

    3-6

    Chapter 3 Functions and Operations

    MODE=FREQ:

    SOFTKEYS: F1

    130

    F2

    259

    517

    BOTTOM

    LIMIT

    ON/OFF

    LIMIT

    EDIT

    LIMIT

    BEEP

    TOPRESOLU-

    TION

    SINGLE

    SWEEP

    TRACE

    MATH

    FREQ/DIST AMPLITUDE SWEEP

    Figure 3-3. Frequency Mode Soft Key Labels

    MODE=POWER MONITOR:

    SOFTKEYS: UNITS

    REL

    OFFSET

    ZERO

    Figure 3-4. Power Monitor Mode Soft Key Labels

  • 3-7

    Chapter 3 Functions and Operations

    MODE=DTF:

    SOFTKEYS:

    BOTTOM

    LIMIT

    ON/OFF

    LIMIT

    EDIT

    LIMIT

    BEEP

    TOPRESOLU-

    TION

    SINGLE

    SWEEP

    TRACE

    MATH

    FREQ/DIST AMPLITUDE SWEEP

    D2

    DTF AID

    MORE

    D1

    LOSS

    CABLE

    WINDOW

    BACK

    PROP

    VEL

    Figure 3-5. Distance to Fault Mode Soft Key Labels

  • 3-8

    Chapter 3 Functions and Operations

    MODE=SPECTRUM ANALYZER:

    SOFTKEYS: CENTER

    SPAN

    START

    STOP

    SCALE

    LIMIT

    ON/OFF

    LIMIT

    EDIT

    REF

    LEVELRBW

    VBW

    MAX

    HOLD

    CONT/

    SINGLE

    OCC

    BW

    FREQ/DIST AMPLITUDE SWEEP

    METHOD

    FULL

    %

    ZERO

    dBc

    MEASURE

    BACK

    Figure 3-6. Spectrum Analyzer Mode Soft Key Labels

  • 3-9

    Chapter 3 Functions and Operations

    LIMIT

    7

    REF

    LEVEL

    SCALE

    LIMIT

    ON/OFF

    LIMIT

    EDIT

    MODE = FREQ, DISTMODE = SPECTRUM ANALYZER

    TOP

    BOTTOM

    LIMIT

    ON/OFF

    LIMIT

    EDIT

    LIMIT

    BEEP

    Figure 3-7. Limit Key Soft key Labels

  • 3-10

    Chapter 3 Functions and Operations

    M1

    M2

    M3

    M4

    ALL

    OFF

    MARKER

    8

    ON/OFF

    ON/OFF

    ON/OFF

    ON/OFF

    EDIT

    EDIT

    EDIT

    EDITDELTA

    M2 - M1

    DELTA

    M3 - M1

    DELTA

    M4 - M1

    MARKER

    TO

    PEAK

    MARKER

    TO

    PEAK

    MARKER

    TO

    PEAK

    MARKER

    TO

    PEAK

    MARKER

    TO

    VALLEY

    SPECTRUM ANALYZER MODE

    MARKER

    TO

    VALLEY

    MARKER

    TO

    VALLEY

    MARKER

    TO

    VALLEYBACK

    BACK

    BACK

    BACK

    MARKER

    FREQ TO

    CENTER

    *

    MARKER

    FREQ TO

    CENTER

    **

    MARKER

    FREQ TO

    CENTER

    MARKER

    FREQ TO

    CENTER

    **

    Figure 3-8. Marker Key Soft Key Labels

  • 3-11

    Chapter 3 Functions and Operations

    ABC

    DEF

    GHI

    JKL

    MNO

    PQR

    STU

    VWX

    YZ

    - . /

    SPACE

    BACK

    SPACE

    SAVE

    DISPLAY

    9

    TOP

    OF

    LIST

    PAGE

    UP

    PAGE

    DOWN

    BOTTOM

    OF

    LIST

    DELETE

    TRACE

    DELETE

    ALL

    TRACES

    RECALL

    DISPLAY

    0

    Figure 3-9. Save Display and Recall Display Soft Key Menus

    OPTIONS

    CLOCK

    SELF

    TEST

    STATUS

    SYS

    UNITS

    PRINTER

    PRINTER

    FIXED

    CW

    CHANGE

    DATE

    FORMAT

    CHANGE

    DATE

    FORMATHOUR

    MINUTE

    MONTH

    DAY

    YEAR

    BACK

    MODE = FREQ, DISTMODE = SPECTRUM ANALYZER

    Figure 3-10. SYS Key Soft Key Menus

  • FREQ/DIST Displays the frequency or distance menu depending on the measurement mode.

    FrequencyMenu

    Provides for setting sweep frequency end points when FREQ mode is selected.Selected frequency values may be changed using the keypad or Up/Down arrowkey.

    � F1 — Opens the F1 parameter for data entry. This is the start value for thefrequency sweep. Press ENTER when data entry is complete.

    � F2 — Opens the F2 parameter for data entry. This is the stop value for thefrequency sweep. Press ENTER when data entry is complete.

    DistanceMenu

    Provides for setting Distance to Fault parameters when a DTF mode is selected.Choosing DIST causes the soft keys, below, to be displayed and the correspond-ing values to be shown in the message area. Selected distance values may bechanged using the keypad or Up/Down arrow key.

    � D1 — Opens the start distance (D1) parameter for data entry. This is the startvalue for the distance range. Press ENTER when data entry is complete.

    � D2 — Opens the end distance (D2) parameter for data entry. This is the endvalue for the distance range. Press ENTER when data entry is complete.

    � DTF AID — Provides interactive help to optimize DTF set up parameters.You will be prompted for system parameter values of maximum distance, fre-quency span, and propagation velocity.

    � MORE — Selects the Distance Sub-Menu, detailed below.

    DistanceSub-Menu

    Provides for setting the cable loss and relative propagation velocity of the coax-ial cable. Selected values may be changed using the Up/Down arrow key or key-pad.

    � LOSS — Opens the Cable Loss parameter for data entry. Enter the loss perfoot (or meter) for the type of transmission line being tested. Press ENTERwhen data entry is complete. (Range is 0.000 to 5.000 dB/m)

    � PROP VEL (relative propagation velocity) — Opens the Propagation Veloc-ity parameter for data entry. Enter the propagation velocity for the type oftransmission line being tested. Press ENTER when data entry is complete.(Range is 0.010 to 1.000)

    � CABLE — Opens a common coaxial cable folder and custom coaxial cablefolder. Select either folder and use the Up/Down arrow key and ENTER keyto make a selection. This feature provides a rapid means of setting both cableloss and propagation velocity. (Refer to Appendix A for a listing of commoncoaxial cables showing values for “Relative Propagation Velocity” and“Nominal Attenuation in dB/m @ 1000 MHz”.) The custom cable folder con-sists of up to 49 user-defined cable parameters downloaded via the Site Mas-ter Software Tools program.

    � WINDOW — Opens a menu of FFT windowing types for the DTF calcula-tion. Scroll the menu using the Up/Down arrow key and make a selectionwith the ENTER key.

    3-12

    Chapter 3 Functions and Operations

  • NOTE: Using windowing:The theoretical requirement for inverse FFT is for the data to extend from zerofrequency to infinity. Side lobes appear around a discontinuity due to the factthat the spectrum is cut off at a finite frequency. Windowing reduces the sidelobes by smoothing out the sharp transitions at the beginning and end of thefrequency sweep. As the side lobes are reduced the main lobe widens therebyreducing the resolution.

    In situations where there may be a small discontinuity close to a large one, sidelobe reduction Windowing should be used cautiously. When distance resolutionis critical Windowing can be reduced. The types of Windowing in order of in-creasing side lobe reduction are: rectangular, nominal side lobe, low side lobe,minimum side lobe. Figures 3-11 thru 3-14, on pages 3-14 and 3-15, are exam-ples of the types of Windowing.

    � BACK — Returns to the Distance Menu.

    3-13

    Chapter 3 Functions and Operations

  • 3-14

    Chapter 3 Functions and Operations

    � � � �

    � � � � � � � � � � � � � � � � � � � �

    � �

    � � �

    � � �

    � � �

    � � �

    � � �

    � � �

    � �

    � �

    � � �

    � � � � � � � � � � � � � � �

    � � � � � � � � � � � � � � � �

    Figure 3-11. Rectangular Windowing Example

    � � � � � � � � � � � � � � � �

    � � � � � � � � � � �

    � � � �

    � � � � � � � � �

    � �

    � � �

    � � �

    � � �

    � � �

    � � �

    � � �

    � �

    � �

    � � �

    � � � � � � � � � � � � � � �

    Figure 3-12. Nominal Side Lobe Windowing Example

  • 3-15

    Chapter 3 Functions and Operations

    � � � � � � � � � � � � � � � �

    � � � � � � � � � � �

    � � � �

    � � � � � � � � �

    � �

    � � �

    � � �

    � � �

    � � �

    � � �

    � � �

    � �

    � �

    � � �

    � � � � � � � � � � � � � � �

    Figure 3-13. Low Side Lobe Windowing Example

    � � � � � � � � � � � � � � � �

    � � � � � � � � � � � � � � � � � � � �

    � � � �

    � �

    � � �

    � � �

    � � �

    � � �

    � � �

    � � �

    � �

    � �

    � � �

    � � � � � � � � � � � � � � �

    Figure 3-14. Minimum Side Lobe Windowing Example

  • Choosing FREQ/DIST in Spectrum Analyzer mode causes the soft keys, below, to be dis-played and the corresponding values to be shown in the message area.

    � CENTER � Sets the center frequency of the Spectrum Analyzer display . En-ter a value using the Up/Down arrow key or keypad, press ENTER to accept,ESCAPE to restore previous value.

    � SPAN � Sets the user-defined frequency span. Use the Up/Down arrow keyor keypad to enter a value in MHz. Also brings up FULL and ZERO softkeys.

    � FULL span sets the Spectrum Analyzer to its maximum frequency span.

    � ZERO span sets the span to 0 Hz. This displays the input signal in an am-plitude versus time mode, which is useful for viewing modulation.

    � START � Sets the Spectrum Analyzer in the START-STOP mode. Enter astart frequency value (in MHz) using the Up/Down arrow key or keypad,press ENTER to accept, ESCAPE to restore.

    � STOP � Sets the Spectrum Analyzer in the START-STOP mode. Enter astop frequency value (in MHz) using the Up/Down arrow key or keypad,press ENTER to accept, ESCAPE to restore.

    3-16

    Chapter 3 Functions and Operations

  • AMPLITUDE Displays the amplitude or scale menu depending on the measurement mode.

    AmplitudeMenu

    Provides for changing the display scale. Selected values may be changed usingthe Up/Down arrow key or keypad.

    Choosing AMPLITUDE in FREQ or DTF measurement modes causes the softkeys, below, to be displayed and the corresponding values to be shown in themessage area.

    Pressing the LIMIT key on the keypad will also call up this menu.

    � TOP — Opens the top parameter for data entry and provides for setting thetop scale value. Press ENTER when data entry is complete.

    � BOTTOM — Opens the bottom parameter for data entry and provides for set-ting the bottom scale value. Press ENTER when data entry is complete.

    � LIMIT ON/OFF — Turns Limit OFF, if currently ON. If Limit is currentlyOFF, turns it ON and opens the Limit parameter for data entry. Press ENTERwhen data entry is complete.

    � LIMIT EDIT — Opens the Limit Line for data entry using the Up/Down arrowkey or key pad entry. Press ENTER when data entry is complete.

    � LIMIT BEEP — Toggles the Limit beep sound on or off. When on, the SiteMaster sounds a beep when the measured value is above the Limit Line.

    Choosing AMPLITUDE in SPECTRUM ANALYZER mode causes the soft keys,below, to be displayed and the corresponding values to be shown in the messagearea.

    � REF LEVEL � Activates the amplitude reference level functions that let theuser adjust the reference level. Use the Up/Down arrow key or key pad to en-ter the desired reference level. Press ENTER when data entry is complete.

    � SCALE � Use Up/Down arrow key or key pad entry to adjust the scale dis-play from 2 to 15 dB/division, in one dB increments. Press ENTER when dataentry is complete.

    � LIMIT ON/OFF — Turns Limit OFF, if currently ON. If Limit is currentlyOFF, turns it ON and opens the Limit parameter for data entry. Press ENTERwhen data entry is complete.

    � LIMIT EDIT — Opens the Limit Line for data entry using the Up/Down arrowkey or key pad entry. Press ENTER when data entry is complete.

    3-17

    Chapter 3 Functions and Operations

  • SWEEP Displays the Sweep function soft key menu for the current operating mode.

    Sweep Menu Provides for changing the display resolution, single or continuous sweep, andaccess to the Trace Math functions.

    Choosing SWEEP in FREQ or DTF measurement modes causes the soft keysbelow to be displayed.

    � RESOLUTION — Opens the display to change the resolution. Choose 130,259, or 517 data points. (Not active in DTF mode. In DTF mode, resolutioncan be adjusted through the DTF-AID table.)

    � SINGLE SWEEP — Toggles the sweep between single sweep and continu-ous sweep. In single sweep mode, each sweep must be activated by theRUN/HOLD button.

    � TRACE MATH — Opens up the Trace Math functions (trace-memory ortrace+memory) for comparison of the real time trace in the display with anyof the traces from memory. (Not available in DTF mode.)

    Choosing SWEEP in SPECTRUM ANALYZER mode causes the soft keys belowto be displayed.

    � RBW � Activates the resolution bandwidth functions. They let users manu-ally adjust the resolution’s bandwidth to the desired value (10 kHz,. 30 kHz,100 kHz, or 1 MHz) by scrolling using the Up/Down arrow key. Select de-sired value and press ENTER when complete.

    � VBW � Activates the video bandwidth function. It lets users manually adjustthe resolution’s bandwidth to the desired value (3 kHz, 10 kHz,. 30 kHz, or300 kHz) by scrolling using the Up/Down arrow key. Select desired valueand press ENTER when complete.

    � MAX HOLD � Activates the max hold function. It displays and holds themaximum response of the input signal trace.

    � CONT/SINGLE � Toggles between continuous and single sweep.

    � OCC BW � Activates the second level occupied bandwidth menu.

    � OCC BW (second level)

    � METHOD � Selects the method to be used, dB Down or % of Power.

    � % � Enter the desired % of occupied bandwidth to be measured.

    � dBc � Enter the desired power level (dBc) to be measured.

    � MEASURE � Takes a measurement.

    � BACK � Returns to the top-level OCC BW menu.

    3-18

    Chapter 3 Functions and Operations

  • MARKER Choosing MARKER causes the soft keys, below, to be displayed and the corre-sponding values to be shown in the message area. Selected frequency marker ordistance marker values may be changed using the keypad or Up/Down arrowkey.

    � M1 — Selects the M1 marker parameter and opens the Markers second levelmenu.

    � M2 — Selects the M2 marker parameter and opens the Markers second levelmenu.

    � M3 — Selects the M3 marker parameter and opens the Markers second levelmenu.

    � M4 — Selects the M4 marker parameter and opens the Markers second levelmenu.

    � ALL OFF — Turns all markers off.

    Markers(second level)

    Provides for turning the selected marker on and off and for setting marker val-ues. Selected frequency marker and distance marker values can be changed us-ing the keypad or Up/Down arrow key.

    Choosing M1, M2, M3, or M4 in FREQ or DTF measurement modes causes thesoft keys, below, to be displayed and the corresponding values to be shown inthe message area.

    � ON/OFF — Turns the selected marker on or off.

    � EDIT — Opens the selected marker parameter for data entry. Press ENTERwhen data entry is complete or ESCAPE to restore the previous value.

    � DELTA (Mx-M1) — Displays delta amplitude value for as well as delta fre-quency or distance for the selected marker with respect to the M1 marker.

    � MARKER TO PEAK — Places the selected marker at the frequency or dis-tance with the maximum amplitude value.

    � MARKER TO VALLEY — Places the selected marker at the frequency or dis-tance with the minimum amplitude value.

    � BACK — Returns to the Main Markers Menu.

    Choosing M1, M2, M3, or M4 in SPECTRUM ANALYZER mode causes the softkey, described below, to be displayed in place of the above MARKER TOVALLEY softkey.

    � MARKER FREQ TO CENTER — Places the selected marker to the center ofthe Spectrum Analyzer display.

    3-19

    Chapter 3 Functions and Operations

  • SYS Displays the System menu softkey selections.

    � OPTIONS — Displays a second level of functions.

    � CLOCK — Displays a second level of functions.

    � SELF TEST — Start an instrument self test.

    � STATUS — Displays instrument status.

    OptionsSub-Menu

    � UNITS — Select the unit of measurement, either English (feet) or metric (me-ters). (Not available in Spectrum Analyzer mode.)

    � PRINTER — Displays a menu of supported printers. Use the Up/Down arrowkey and ENTER key to make the selection.

    � FIXED CW — Toggles the fixed CW function ON or OFF. When ON, sweeptime is reduced and immunity to RF interference is less. When OFF, (normalmode) the unit provides maximum RF interference immunity. (Not availablein Spectrum Analyzer mode.)

    � CHANGE DATE FORMAT — Toggles the date format between MM/DD/YY,DD/MM/YY, and YY/MM/DD.

    � BACK — Returns to the top level SYS menu.

    ClockSub-Menu

    � HOUR — Enter the hour (0-23) using the Up/Down arrow key or the keypad.Press ENTER when data entry is complete or ESCAPE to restore the previousvalue. (The clock must be set before automatic time/date stamp is activatedfor trace store.)

    � MINUTE — Enter the minute (0-59) using the Up/Down arrow key or thekeypad. Press ENTER when data entry is complete or ESCAPE to restore theprevious value.

    � MONTH — Enter the month (1-12) using the Up/Down arrow key or the key-pad. Press ENTER when data entry is complete or ESCAPE to restore the pre-vious value.

    � DAY — Enter the day using the Up/Down arrow key or the keypad. PressENTER when data entry is complete or ESCAPE to restore the previousvalue.

    � YEAR — Enter the year (1997-2036) using the Up/Down arrow key or thekeypad. Press ENTER when data entry is complete or ESCAPE to restore theprevious value.

    � BACK — Returns to the top-level SYS menu.

    SAVEDISPLAY

    Choosing Save Display activates the alphanumeric menu for trace storage. Usethe soft keys to enter a label for the saved trace.

    For example, to save a display with the name “TRACE1” press the soft key forthe group that contains the letter “T” and then press the “T” soft key. Press thesoft key for the group that contains the letter “R” then press the “R” soft key.Continue for the rest of the letters. Use the number keys on the numeric keypadto enter numbers. Use the softkeys and keypad as necessary to enter the entirename, then press ENTER to complete the process.

    The BACK SPACE softkey removes the currently highlighted letter in the tracename.

    3-20

    Chapter 3 Functions and Operations

  • RECALLDISPLAY

    Recalls a trace from memory for viewing or to be used as a trace overlay. Selec-tions are:

    � TOP OF LIST — Move the selection cursor to the top (first) memory loca-tion.

    � PAGE UP — Move the selection cursor to the top of the previous tracememory location page. Each page contains 15 trace memory locations.

    � PAGE DOWN — Move the selection cursor to the top of the next trace mem-ory location page.

    � BOTTOM OF LIST — Move the selection cursor to the bottom (last) memorylocation.

    � DELETE TRACE — Delete the selected trace from memory. This option isnot available when using Trace Overlay.

    � DELETE ALL TRACES — Delete all traces from memory. This option is notavailable when using Trace Overlay.

    3-21

    Chapter 3 Functions and Operations

  • Power Monitor MenuSelecting POWER MONITOR from the Mode menu causes the soft keys, described below,to be displayed and the corresponding values shown in the message area.

    � UNITS — Toggles between dBm and Watts.

    � REL — Turns relative mode OFF, if currently ON. If relative mode is cur-rently OFF, turns it ON and causes the power level to be measured and savedas the base level. Subsequent measurements are then displayed relative to thissaved value. With units of dBm, relative mode displays dBr; with units ofWatts, relative mode displays % (percent).

    � OFFSET — Turns Offset OFF, if currently ON. If Offset is currently OFF,turns it ON and opens the Offset parameter for data entry. Press ENTERwhen data entry is complete.Offset is the attenuation (in dB) inserted in the line between the DUT and theRF detector. The attenuation is added to the measured input level prior to dis-play.

    � ZERO — Turns Zero OFF, if currently ON. If Zero is currently OFF, thissoftkey turns it ON and initiates collection of a series of power level samples,which are averaged and saved. This saved value is then subtracted from sub-sequent measurements prior to display.

    3-22

    Chapter 3 Functions and Operations

  • PrintingPrinting is accomplished by selecting an available printer and pressing the print key as de-scribed below. Refer to the particular printer operating manual for specific printer settings.

    Printing a Screen

    Step 1. Connect the printer as shown in Figure 3-15.

    Step 2. Obtain the desired measurement display

    Step 3. Press the SYS key and the OPTIONS soft key (Figure 3-16) .

    3-23

    Chapter 3 Functions and Operations

    HOLDRUN

    STARTCAL

    AUTOSCALE

    SAVESETUP

    RECALLSETUP

    LIMIT MARKER

    SAVEDISPLAY

    RECALLDISPLAY

    PRINT

    MODE FREQ/DIST AMPLITUDE SWEEP

    SYS

    ENTER

    CLEAR

    ESCAPE

    ONOFF

    /

    1 2

    4

    5 6

    7 8

    9 0

    3

    +-

    .

    Site Master S114BQ

    625.0 2500.0

    1384.45 MHz

    2096.66 MHz

    SEIKOPRINTER

    HP 340DESKJET

    SERIAL CABLE2000-1012

    SERIAL-TO-PARALLELINTERFACE CABLE

    2000-753

    Figure 3-15. Site Master Printer Setup

    OPTIONS

    SYS

    Site Master S114BQ

    CLOCK

    OPTIONS

    SELF TEST

    STATUS

    HOLDRUN

    STARTCAL

    AUTOSCALE

    SAVESETUP

    RECALLSETUP

    LIMIT MARKER

    SAVEDISPLAY

    RECALLDISPLAY

    PRINT

    MODE FREQ/DIST AMPLITUDE SWEEP

    SYS

    ENTER

    CLEAR

    ESCAPE

    ONOFF

    /

    1 2

    4

    5 6

    7 8

    9 0

    3

    +-

    .

    Figure 3-16. SYS Key and OPTIONS Soft Key

  • Step 4. Press the PRINTER soft key and select from the displayed menu of supportedprinters.

    Step 5. Press the PRINT key. (Figure 3-17).

    Printer Switch Settings

    Set the switches, SW1, SW2, and SW3, on the Seiko DPU-414 thermal printer as follows:

    Set the switches on the serial-to-parallel interface cable to all other printers as follows:

    3-24

    Chapter 3 Functions and Operations

    HOLDRUN

    STARTCAL

    AUTOSCALE

    SAVESETUP

    RECALLSETUP

    LIMIT MARKER

    SAVEDISPLAY

    RECALLDISPLAY

    PRINT

    MODE FREQUENCY AMPLITUDE BANDWIDTH

    SYS

    ENTER

    CLEAR

    ESCAPE

    ONOFF

    /

    1 2

    4

    5 6

    7 8

    9 0

    3

    +-

    .

    PRINTER

    PRINT

    Site Master S114BQ

    CHANGE

    DATE

    PRINTER

    Figure 3-17. PRINTER Soft Key and PRINT Key

    Switch 1 2 3 4 5 6 7 8

    SW1 OFF ON ON ON ON OFF ON ON

    SW2 ON ON ON ON ON ON ON OFF

    SW3 ON ON ON OFF OFF ON ON ON

    SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8

    OFF ON OFF OFF OFF OFF ON OFF

  • SymbolsTable 3-1 provides a listing of the symbols used as condition indicators on the LCD display.

    Self TestAt turn-on, the Site Master runs through a series of quick checks to ensure the system isfunctioning properly. Note that the battery voltage and temperature are displayed in thelower left corner below the self test message. If the battery is low, or if the ambient temper-ature is not within the specified operational range, Self Test will fail. If Self Test fails andthe battery is fully charged and the Site Master is within the specified operating range, callyour Anritsu Service Center.

    3-25

    Chapter 3 Functions and Operations

    Icon Symbol

    Site Master is in Hold for power conservation. To resume sweeping, pressthe RUN/HOLD key. After 10 minutes without a key press, the Site Masterwill automatically activate the power conservation mode.

    Integrator Failure

    Lock fail indication. Check battery. (If the Site Master fails to lock with afully charged battery, call your Anritsu Service Center.)

    When calibration is performed, the Site Master stores the ambient temper-ature. If the temperature drifts outside the specified range, this indicatorwill flash. A recalibration at the current temperature is recommended.

    Indicates the remaining charge on the battery. The inner white rectanglegrows longer as the battery charge depletes.

    Indicates internal data processing.

    Table 3-1. LCD Icon Symbols

    HOLD

    dx�

    T

  • Error CodesSelf Test Errors

    A listing of Self Test Error messages is given in Table 3-2.

    3-26

    Chapter 3 Functions and Operations

    Error Message Description

    BATTERY LOW Battery voltage is less than 9.5 volts. Charge battery. If condition per-sists, call your Anritsu Service Center.

    EXTERNALPOWER LOW

    External supply voltage is less than 12.5 volts. Call your Anritsu Ser-vice Center

    PLL FAILED Phase-locked loops failed to lock. Charge battery. If condition persistswith a fully charged battery, call your Anritsu Service Center

    LO LOCKFAILED

    Local Oscillator in the Spectrum Analyzer failed to lock. Charge bat-tery. If condition persists with a fully charged battery, call your AnritsuService Center.

    INTEGRATORFAILED

    Integration circuit could not charge to a valid level. Charge battery. Ifcondition persists with a fully charged battery, call your Anritsu Ser-vice Center.

    EEPROM R/WFAILED

    Non-volatile memory system has failed. Call your Anritsu ServiceCenter.

    OUT OF TEMP.RANGE

    Ambient temperature is not within the specified operating range. If thetemperature is within the specified operating range and the conditionpersists, call your Anritsu Service Center.

    Note: A listing of current Anritsu service centers is given in Table 1-2 , page 1-8.

    Table 3-2. Self Test Error Messages

  • Range Errors

    A listing of Range Error messages is given in Table 3-3.

    3-27

    Chapter 3 Functions and Operations

    Error Message Description

    RANGEERROR:F1 > F2

    The start (F1) frequency is greater than the stop (F2) frequency.

    RANGEERROR:D1 > D2

    The start (D1) distance is greater than the stop (D2) distance.

    RANGEERROR:D2 >DMax=xx.x ft (m)

    The stop distance (D2) exceeds the maximum unaliased range. Thisrange is determined by the frequency span, number of points,and relative propagation velocity:

    MaximumUnaliased Rangedp V

    F Fmeters

    f

    ( . ) ( ) ( )1 5 10

    2 1

    8

    Where: dp is the number of data points (128, 256, or 512)Vf is the relative propagation velocityF2 is the stop frequency in HzF1 is the start frequency in Hz

    Refer to Figure 3-18, page 3-28, for a plot of maximum range versusfrequency span.

    RANGE ERROR:TOP=BOTTOM

    The RL scale parameter top value is greater than or equal to its bottomvalue.

    CALINCOMPLETE

    A complete open, short, and load calibration must be performed bef-ore calibration can be turned on.

    DIST REQUIRESF1 < F2

    Valid distance to fault plots require a non-zero frequency span.

    DIST REQUIRESCAL

    Distance-to-fault measurements do not provide usable data with CALOFF.

    NO STOREDSWEEP AT THISLOCATION

    Attempting to recall a display from a location that has not been previ-ously written to. That is, the location does not contain stored sweep.

    USE OPTIONSMENU TOSELECT APRINTER

    Attempting to print a display with no printer selected. Select a printer,then retry.

    DISTANCE ANDCABLEINSERTION LOSSMODE AREINCOMPATIBLE

    DTF measurements only display RL or SWR versus distance.

    CANNOT ZERONO DETECTORINSTALLED

    Attempting to perform a Power Monitor zero adjust function with noRF detector connected to the Site Master.

    CANNOT ZEROINPUT SIGNALTOO HIGH

    Attempting to perform a Power Monitor zero adjust function with aninput of greater than –20 dBm.

    Table 3-3. Range Error Messages (1 of 2)

  • 3-28

    Error Message Description

    POWER MONITOROPTION NOTINSTALLED

    Attempting to enter Power Monitor mode with no option 5 installed.

    Table 3-3. Range Error Messages (2 of 2)

    Figure 3-18. Maximum Distance and Resolution vs Frequency Span

  • Using the Soft Carrying CaseThe soft carrying case has been designed such that the strap can be unsnapped to allow thecase to be easily oriented horizontally; thus allowing the Anritsu controls to be more easilyaccessed (Figure 3-19).

    3-29/3-30

    Chapter 3 Functions and Operations

    Figure 3-19. Using the Site Master Soft Carrying Case

  • Chapter 4Measurements

    IntroductionThis chapter provides a description of the Site Master measurement functions and examplesof frequency domain, distance domain, and spectrum analyzer measurements .

    Measurement FunctionsSite Master operation is divided into four measurement modes: frequency domain, distancedomain, spectrum analysis, and power monitor.

    � Frequency domain measurements consist of Return Loss (RL), Standing Wave Ratio(SWR), and Cable Loss (CL) made over a selectable frequency range. SWR and RL char-acterize the magnitude of reflections present in a device or transmission line. CL mea-surements display the one-port insertion loss of a transmission line over frequency.

    � Distance domain measurements—commonly known as distance-to-fault (DTF)—aremade over a selectable distance range. They include RL or SWR, but they also return in-formation that can help locate discontinuities in a transmission line. CL cannot be meas-ured in the distance domain.

    � Spectrum Analysis�Typical measurements include in-band interference, antenna align-ment, and cell coverage. Measurements can be easily made by using the main instrumentfunctions: frequency, span, amplitude and sweep. A full range of marker capabilities suchas peak, center and delta functions are provided for fast, comprehensive measurement ofdisplayed signals. Limit lines are available for creating quick, simple pass/fail measure-ments.

    � Power monitor measurements can be either absolute or relative to some base power level,and can be displayed in either dBm or Watts. To allow measurement and display ofpower levels above the unit's specified input, the user may attenuate the signal and enterthe corresponding offset. The offset is added to the measured input power prior to dis-play. Finally, a zero adjust function is provided to allow subtraction of an inherent“noise” level prior to display.

    CAUTION: The measurement system MUST be calibrated at the ambient tem-perature prior to making a measurement. You must calibrate when the setupfrequency is changed. Calibrations are stored with each of the setups.

    It is recommended that open, short, load calibration be performed on the Site Master priorto measurements. This gives confidence to the operator that the measurement performed isaccurate and system uncertainties have been minimized.

    4-1

    4

  • Power On ProcedureThe Site Master is designed specifically for field environments and applications requiringmobility. As such, it is a lightweight, handheld, battery operated unit which can be easilycarried to any location, and is capable of up to 2.5 hours of continuous operation from afully charged battery. Built-in energy conservation features allow battery life to be extendedover an eight-hour workday. The Site Master can also be powered by a 12.5 Vdc externalsource. The external source can be either the Anritsu AC-DC Adapter (P/N 40-115) or 12.5Vdc Automotive Cigarette Lighter Adapter (P/N 806-62) provided.

    Step 1. Press the ON/OFF key.

    The Site Master takes about five seconds to perform a series of self-diagnosticand adjustment routines. At completion, the screen displays the Anritsu logo, themodel number, and the version of firmware installed.

    Step 2. Press ENTER to continue, or wait for one minute.

    The Site Master is now ready for operation.

    Setting the Time/DateThe Site Master clock must be set for the correct local time and date so that saved traceswill reflect an accurate time/date stamp. To set the clock:

    Step 1. Press the SYS key.

    Step 2. Press the HOUR soft key and enter the correct hour using the key pad or theUp/Down arrow key. Press ENTER to complete.

    Step 3. Press the MINUTE soft key and enter the correct minutes using the key pad orthe Up/Down arrow key. Press ENTER to complete.

    Step 4. Press the MONTH, DAY, and YEAR soft keys and enter the correct month, dayand year using the key pad or the Up/Down arrow key. Press ENTER after eachentry to complete.

    4-2

    Chapter 4 Measurements

  • Calibration ProcedureThe following procedure provides the steps necessary to perform an Open-Short-Load(OSL) calibration. Calibration is done with the maximum 517 data points and is valid for130 and 259 data point settings. Refer to Figure 4-1 for setup.

    Step 1. Press the MODE key.

    Step 2. Use the Up/Down arrow key to scroll to FREQ - SWR or RETURN LOSS.

    Step 3. Press the ENTER key to select the SWR or Return Loss measurement mode.

    Selecting the Frequency Range

    The following procedure selects the frequency range for the calibration.

    Step 4. Press the FREQ/DIST key.

    Step 5. Press the F1 soft key.

    Step 6. Enter 2 or a user-defined frequency using the key pad or the Up/Down arrowkey.

    Step 7. Press ENTER to set F1 to 2 MHz.

    Step 8. Press the F2 soft key.

    Step 9. Enter 1, 0, 0, 0 or a user-defined frequency using the keypad or the Up/Down ar-row key.

    Step 10. Press ENTER to set F2 to 1000 MHz.

    Step 11. Check that the FREQ (MHz) scale in the display area indicates the new fre-quency start and stop values (for example: F1 = 2 MHz, F2 = 1000 MHz).

    4-3

    Chapter 4 Measurements

    HOLDRUN

    STARTCAL

    AUTOSCALE

    SAVESETUP

    RECALLSETUP

    LIMIT MARKER

    SAVEDISPLAY

    RECALLDISPLAY

    PRINT

    MODE FREQ/DIST AMPLITUDE SWEEP

    SYS

    ENTER

    CLEAR

    ESCAPE

    ONOFF

    /

    1 2

    4

    5 6

    7 8

    9 0

    3

    +-

    .

    Site Master S114BQ

    OPEN

    LOAD

    SHORT CALIBRATION

    RFOUT/REFLECTIONTEST PORT

    TEST PORT CABLE (OPTIONAL)

    Figure 4-1. Calibration Setup

  • Performing a Calibration

    The following procedure details how to perform the calibration.

    Step 12. Press the START CAL key. The message “Connect Open to RF OUT port” willappear in the display.

    Step 13. Connect the calibrated Open and press the ENTER key. The messages “MEA-SURING OPEN” and “CONNECT SHORT TO RF OUT” will appear.

    Step 14. Remove the Open, connect the calibrated Short and press the ENTER key. Themessages “MEASURING SHORT” and “CONNECT LOAD TO RF OUT” willappear.

    Step 15. Remove the Short, connect the calibrated Load and press the ENTER key. Themessages “MEASURING LOAD ” will appear.

    Step 16. Verify that the calibration has been properly performed by checking that themessage “CAL ON” is displayed in the upper left corner of the display.

    Setting the Amplitude Scale

    The following procedure details how to set the Amplitude Scale.

    Step 1. Press the AMPLITUDE or LIMIT key to call up the Scale menu.

    Step 2. Press the TOP soft key and, for SWR mode, enter 1.1 using the key pad or theUp/Down arrow key. For Return Loss mode, enter 0. Press ENTER to completethe data entry.

    Step 3. Press the BOTTOM soft key and, for SWR mode, enter 1 using the key pad orthe Up/Down arrow key. For Return Loss mode, enter 54. Press ENTER to com-plete the data entry.

    NOTE:Figures 4-2 and 4-3 on page 4-6 show the typical responses of a valid calibra-tion with a load attached to the test port.To change the number of data points, press the SWEEP key, followed by theRESOLUTION soft key. Select 130, 259, or 517 data points.

    Saving the Setup

    The following procedure saves a setup to memory.

    Step 1. To save the configuration in one of the 10 available user setup locations, pressSAVE SETUP and use the key pad or the Up/Down arrow key to select a loca-tion (1 - 10), then press ENTER.

    Recalling a Setup

    The following procedure recalls a setup from memory.

    Step 1. Press the RECALL SETUP key.

    Step 2. Select the desired setup using the Up/Down arrow key and press ENTER to re-call the display.

    4-4

    Chapter 4 Measurements

  • Saving a Display to Memory

    The following procedure saves a display to memory.

    Step 1. Press the SAVE DISPLAY key to activate the alphanumeric menu for trace stor-age.

    Step 2. Use the soft keys to enter a label for the saved trace.

    For example, to save a display with the name “TX1 RETURN LOSS” press thesoft key group that contains the letter “T” then press the “T” soft key. Press thesoft key group that contains the letter “X” then press the “X” soft key. Press thenumber “1” key on the numeric keypad. Use the softkeys and keypad as neces-sary to enter the entire name, then press ENTER to complete the process.

    NOTE: More than one trace can be saved using the same alphanumeric name,as traces are stored chronologically, using the time/date stamp.

    Recalling a Display From Memory

    The following procedure recalls a previously saved display from memory.

    Step 1. Press the RECALL DISPLAY key.

    Step 2. Select the desired display using the Up/Down arrow key and press ENTER to re-call the display.

    4-5

    Chapter 4 Measurements

  • NOTES: For best calibration results–compensation for all measurement systemuncertainties–ensure that the Open/Short/Load is at the end of the test port oroptional extension cable; that is, at the same point as the antenna or device tobe tested will be connected.For best results, use a phase stable Test Port Extension cable. In a typical lab-oratory cable, bending subsequent to the calibration will cause uncompensatedphase reflections inside the cable. Cables that are not phase stable may causemeasurement errors that become more pronounced as the test frequency in-creases.

    4-6

    Chapter 4 Measurements

    Figure 4-2. SWR Measurement Mode Calibration Results

    Figure 4-3. Return Loss Measurement Mode Calibration Results

  • SWR (Return Loss) and Cable Loss MeasurementThe following frequency domain measurement is an example of a Standing Wave Ratio (orReturn Loss) and Cable Loss measurement made over a selectable frequency range. Thismeasurement example determines the quality and loss of the test port cable or device undertest.

    Required Equipment

    � Site Master Model S114BQ

    � Precision Open/Short, Anritsu 22N50 and Precision Load, Anritsu SM/PL orPrecision Open/Short/Load, Anritsu OSLN50LF

    � Test Port Extension Cable, Anritsu 15NNF50-1.5A

    Device-Under-Test Specification

    Procedure

    Step 1. Press the ON/OFF key on the Site Master.

    Selecting the Measurement Mode

    Step 2. Press the MODE key.

    Step 3. Use the Up/Down arrow key to scroll to FREQ-SWR or FREQ-RETURN LOSS.

    Step 4. Press the ENTER key to select Frequency SWR or Return Loss measurementmode.

    Selecting the Frequency Range

    Step 5. Press the FREQ/DIST key.

    Step 6. Press the F1 soft key.

    Step 7. Enter 2 using the key pad or the Up/Down arrow key.

    Step 8. Press ENTER to set F1 to 2 MHz.

    Step 9. Press the F2 soft key.

    Step 10. Enter 1, 0, 0, 0 using the keypad or the Up/Down arrow key.

    Step 11. Press ENTER to set F2 to 1000 MHz.

    Step 12. Check that the FREQ (MHz) scale in the display area indicates the new fre-quency start and stop values (F1 = 2 MHz, F2 = 1000 MHz).

    4-7

    Chapter 4 Measurements

    Type Typical Loss @1.5m Vg Return Loss SWR

    15NNF50-1.5A0.03 dB @2 MHz0.22 dB @300 MHz0.32 dB @500 MHz0.54 dB @900 MHz

    0.86 21 dB �1.20

  • Performing a Calibration

    Step 13. Press the START CAL key. Follow the instructions that appear in the messagearea.

    Step 14. Connect the Open, Short, and Load component to the test port and press theENTER key as prompted after connecting each component.

    Refer to the “Performing a Calibration” procedure on page 4-4 for detailed cali-bration steps.

    NOTES:For best calibration results — compensation for all measurement system uncer-tainties — ensure that the Open/Short/Load is at the end of the test port or op-tional extension cable; that is, at the same point that you will connect theantenna or device to be tested.

    For best results, use a phase stable Test Port Extension Cable (see OptionalAccessories). If you use a typical laboratory cable to extend the Anritsu test portto the device-under-test, cable bending subsequent to the Open/Short/Load cal-ibration will cause uncompensated phase reflections inside the cable. Thus, ca-bles which are not phase stable may cause measurement errors that are morepronounced as the test frequency increases.

    For optimum calibration, Anritsu recommends using precision calibration com-ponents.

    4-8

    Chapter 4 Measurements

  • SWR or Return Loss Measurement

    Step 15. Disconnect the Load and connect the test port extension cable to the Site Mastertest port.

    Step 16. Connect the Load to the open end of the test port extension cable as shown inFigure 4-4.

    Step 17. Observe the displayed measurement. Figures 4-5 and 4-6 show typical SWR andReturn Loss measurements with markers and limit line set.

    Set the Amplitude Scale and Limit Line

    The following procedure sets the top and bottom scale display.

    Step 18. Press the AMPLITUDE or LIMIT key to call up the Scale Menu.

    Step 19. Press the TOP soft key and, for SWR mode, enter 1.3 using the key pad or theUp/Down arrow key. For Return Loss mode, enter 0. Press ENTER to set the topscale.

    Step 20. Press the BOTTOM soft key and, for SWR mode, enter 1 using the key pad orthe Up/Down arrow key. For Return Loss mode, enter 54. Press ENTER to setthe bottom scale.

    Step 21. Press the LIMIT EDIT soft key. For SWR mode, enter 1.2. For Return Lossmode, enter 21 using the keypad or Up/Down arrow key. Press ENTER to set thelimit line.

    4-9

    Chapter 4 Measurements

    HOLDRUN

    STARTCAL

    AUTOSCALE

    SAVESETUP

    RECALLSETUP

    LIMIT MARKER

    SAVEDISPLAY

    RECALLDISPLAY

    PRINT

    MODE FREQ/DIST AMPLITUDE SWEEP

    SYS

    ENTER

    CLEAR

    ESCAPE

    ONOFF

    /

    1 2

    4

    5 6

    7 8

    9 0

    3

    +-

    .

    Site Master S114BQ

    LOAD

    SHORT

    MEASUREMENT

    RFOUT/REFLECTIONTEST PORT

    OPEN

    LOAD

    SHORT CALIBRATION

    Figure 4-4. Cable Measurement Test Setup

  • Setting the Markers

    Step 22. Press the MARKER key to call up the Markers menu.

    Step 23. Press the M1 soft key to select the M1 marker function. Press the EDIT soft keyand enter 2 using the keypad or Up/Down arrow key. Press ENTER to set M1 to2 MHz. (Note: pressing the ON/OFF soft key activates or deactivates the M1marker function.)

    Step 24. Press the BACK soft key to return to the Markers menu.

    Step 25. Repeat steps 22 and 23 for marker M2. Set M2 to 300 MHz, M3 to 500 MHz,and M4 to 900 MHz (Figures 4-5 and 4-6 depict the SWR and Return Loss mea-surements).

    NOTE:Refer to page 4-4 for instructions on saving and recalling a setup or display.

    4-10

    Chapter 4 Measurements

    Figure 4-5. Cable SWR Measurement Results

    Figure 4-6. Cable Return Loss Measurement Results

  • Cable Loss MeasurementThe following frequency domain measurement is an example of a Cable Loss measurementmade over a selectable frequency range using the one-port loss method. This method givesa quick and relatively accurate cable loss measurement without resorting to the two-port“thru” insertion loss method.

    NOTE:If CAL ON is not displayed in the upper left of the Site Master display, of if theSWR/Return Loss measurement steps from earlier in this chapter were notcompleted, the Site Master must be calibrated before continuing.

    Step 26. Disconnect the load from the end of the cable and replace it with a short.

    Step 27. Press the MODE key.

    Step 28. Use the Up/Down arrow key to scroll to CABLE LOSS - ONE PORT.

    Step 29. Press ENTER to select Cable Loss measurement mode.

    Setting the Amplitude Scale

    The following procedure sets the scale display.

    Step 30. Press the AMPLITUDE key to call up the Scale Menu.

    Step 31. Press the TOP soft key and enter 0 using the keypad or Up/Down arrow key.Press ENTER to set the top scale.

    Step 32. Press the BOTTOM soft key and enter 1 using the keypad or Up/Down arrowkey. Press ENTER to set the bottom scale.

    NOTE:An alternative method of setting the amplitude scale is to use the AUTO SCALEkey.

    Setting the Markers

    The following procedure sets the markers. Skip this section if the SWR/Return Loss mea-surement steps from earlier in this chapter were completed.

    Step 33. Press the MARKER key to call up the Markers menu.

    Step 34. Press the M1 soft key to select the M1 marker function. Press the EDIT soft keyand enter 2 using the keypad or Up/Down arrow key. Press ENTER to set M1 to2 MHz. (Note: pressing the ON/OFF soft key activates or deactivates the M1marker function.)

    Step 35. Press the BACK soft key to return to the Markers menu.

    4-11