spectrapak 315

Upload: amirouche15

Post on 02-Jun-2018

354 views

Category:

Documents


8 download

TRANSCRIPT

  • 8/10/2019 Spectrapak 315

    1/4

    Unitor's Combined Boiler Water Treatment Programme

    SPECTRAPAK 315 Product no: 661 698738

    The tests recommended to maintain boiler water within the desired level of quality when treating with UnitorAutotreat or Combitreat in conjunction with Oxygen Scavenger Plus or Oxygen Control are as follows:

    A. P-alkalinity - Recommended Limits: 100 -300 ppm as

    CaCO3B. Chlorides - 200 ppm maximum as Cl-.C. Condensate pH - 8.3-9.0

    D. Hotwell temperature >80C

    Dosage level of Autotreat/combitreat is based on the P-

    alkalinity value of the boiler water. However, chlorides

    and condensate pH must also be controlled andmaintained as recommended. Knowledge of all relevantparameters is desirable to enable better interpretationand correct application of treatment. To increase the

    condensate pH, use Unitor's Condensate Control inconjunction with Combitreat. It is recommended to doseCondensate Control on a continuous basis, to maintain

    the condensate pH within the recommended range of8.3-9.0 at all times.

    Controlling AlkalinityThe alkalinity is a more accurate indicator of the boilerwater condition than pH when water quality is monitored

    manually. The phenolphthalein (P) Alkalinity is measuredto determine whether the correct conditions of alkalinityexist in the boiler.

    SPECTRAPAK 315

    Controlling ChloridesThe chloride value will reveal any presence of dissolved salts in the boiler. An increase, gradual or sudden, in the

    level of chloride is an indication of contamination by sea water and the chloride level is often used as a referencepoint when controlling rate of blowdown.

    pH BOILER

    Recommended limits of 9.5-11.0. An additional test to determine the pH of the boiler water can be carried out togive a better overall understanding of the boiler water quality.

    pH-CondensateTo control corrosion in a boiler, condensate and feed water section, the condensate pH should be kept between 8.3and 9.0. Monitoring the pH of this water is very important in maintaining a complete Boiler Water TreatmentProgramme.

  • 8/10/2019 Spectrapak 315

    2/4

    TEST RESULTS - COMBINED TREATMENT

    A.Recording - When using Unitor's Boiler Water Management all measurements are taken automatically. Whenmanually dosing, follow the following routine.

    1. Log form - Combined Boiler Water Treatment Log.2. Frequency - Samples should be drawn, tested and results logged minimum every third day.

    B. Reporting - The completed log sheet for the month should be distributed as shown at the bottom of the form, atthe end of each month:

    1. Blue copy - to Unitor Rapid Response Centre in Norway (address labels at back of log pad)2. Beige copy - Vessel owner3. Lilac copy - to be kept onboard

    C. Evaluation

    1. Logs will be reviewed at the Unitor Rapid Response Centre for adherence to recommended specifications, byUnitor's Rapid Response staff.2. A report letter indicating the status of the ship's system, any problems and relevant recommendations will be

    issued to the ship's operator.

    SPECTRAPAK 315Low Pressure Boiler Water Test KitBoiler Water Treatment Test Kit P. ALKALINITY, CHLORIDE & pH

    Product no: 661 698738

    P ALKALINITY TEST1. Take a 200 ml water sample in the stoppered bottle provided.2. Add one P. Alkalinity tablet and shake to disintegrate. If P. Alkalinity is present the sample will turn blue.

    3. Repeat tablet addition until the blue colour changes to permanent yellow.

    CALCULATION

    P. Alkalinity ppm (CaCO3) = (Number of tablets used x 20) -10.For example:lf 8 tablets are used then P. Alkalinity = (8 x 20) -10 = 150 ppm.

    4. Mark this result on the log sheets provided, against the date on which the test was taken.

    CHLORIDE TEST

    1. For boilers under 30 bar (KG/CM2) take a 50 ml sample in the stoppered bottle provided.

    2. Add one chloride tablet and shake to disintegrate, sample will turn yellow if chlorides are present3. Repeat tablet addition until the yellow colour changes to orange/brown.

    CHLORIDE (CONT.) CALCULATION (50 ml SAMPLE)Chloride ppm = (number of tablets used x 20)-20 For example: lf 4 tablets are used then chloride ppm = (4 x 20) -20

    = 60 ppm.

    4. Mark the result obtained on the log sheets provided, against the date on which the test was taken.N.B. For higher expected chloride levels reduce the water sample size e.g. 25 ml sample will give steps of 40 ppm

    per tablet used. For lower expected chloride levels increase the water sample volume e.g. 1OO ml sample will givesteps of 1O ppm per tablet used.

  • 8/10/2019 Spectrapak 315

    3/4

  • 8/10/2019 Spectrapak 315

    4/4

    Water Test Kit Selector

    Application Product RocorNB

    Liquid

    DieselguardNB

    Combitreat Liquitreat Autotreat CondensateControl

    OxygenControl

    OxygenScavenger

    Plus

    Cat.Sulphite

    AlkalinityControl

    HardnessControl

    Enginecooling water

    Rocor NBLiquid

    309

    Enginecooling water

    DieselguardNB

    309

    Combinedboiler watertreatments

    Combitreat 310 310 315/312 315/313 310/sulphite

    Combinedboiler watertreatments

    Liquitreat 310 310

    Combinedboiler watertreatments

    Autotreat 310 315/312 315/313

    Singleapplicationboilertreatments

    CondensateControl

    310 310 311 311

    Singleapplication

    boilertreatments

    Oxygen

    Control315/312 315/312 311/312 311/312

    Singleapplicationboilertreatments

    OxygenScavengerPlus

    315/313 315/313 311/313 311/313

    Singleapplicationboilertreatments

    Cat.Sulphite

    310/sulphite 311/sulphite 311/sulphite

    Singleapplicationboilertreatments

    AlkalinityControl

    311 311/312 311/313 311/sulphite 311

    Singleapplicationboilertreatments

    HardnessControl

    311 311/312 311/313 311/sulphite 311 311

    Can be used alone.Should always be used in combination with other product(s).

    The numbers represent the suitable Spectrapak test kit. In cells with two numbers, the number to the right is anextention kit.Sulphite represents the sulphite mini testkit.

    More information about individual products and test kits is available in the Technical Product Data sheets.