stormwater management report€¦ · stormwater management report golden glades interchange...
TRANSCRIPT
STORMWATER MANAGEMENT REPORT
STORMWATER MANAGEMENT REPORT
GOLDEN GLADES INTERCHANGE PD&E STUDY From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Miami-Dade County, Florida
Financial Management Number: 428358-1-22-01 Efficient Transportation Decision Making (ETDM) Number: 11300
Prepared for Florida Department of Transportation - District Six
Miami, Florida
Prepared by:
Stantec Consulting Services, Inc.
901 Ponce de Leon Boulevard, Suite 900 Coral Gables, Florida 33134
Stantec.com
April 2014
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report ii
EXECUTIVE SUMMARY
This report provides the drainage documentation required to support the Project
Development and Environment (PD&E) Study prepared for the Golden Glades Interchange
(GGI) project area. This report identifies possible locations for stormwater treatment
ponds. In addition, it also evaluates the Right-of-Way (R/W) needed to accommodate the
stormwater management facilities.
The purpose of this project is to provide a system-to-system connection for the SR
826/Palmetto Expressway eastbound to I-95 northbound movement and to improve the
Turnpike southbound to I-95 southbound connection. The ultimate phase will evaluate a
system-to-system connection between new express lanes on SR 826/Palmetto Expressway
and the existing 95 Express Lanes System. The GGI is located in northeastern Miami-Dade
County, Florida. The study area covers approximately 512 Acres and is located in Section
13, Township 52 South and Range 41 East.
Discharge from the study area is bifurcated by the South Florida Rail Corridor (SFRC).
Runoff from the area north of the SFRC ultimately drains northwesterly, within the Turnpike
swales, towards the C-9 Canal. The area south of the SFRC generally drains south, within
2-72” asphalt coated ultra-flow metal pipes under I-95, towards the C-8 Canal. The project
area was divided into seven main drainage systems. The naming convention was chosen so
that the first two characters represent the receiving water body followed by an abbreviation
of the general location of the system. The western portion of the study corridor is within
the Anodyne contamination plume. A one-mile buffer around the contamination plume
covers most of the study area. The Florida Department of Environmental protection (FDEP)
discourages the use of wet ponds or exfiltration trenches within one mile of a superfund
site. As such, water treatment facilities proposed by this study, which fall within the 1-mile
Anodyne buffer, consist of dry-retention and/or dry-detention.
Stormwater management systems proposed by this study meet current water quality
standards as set forth in Chapter 62-302 of the Florida Administrative Code. The approach
to meeting water quality requirements is to provide treatment for the increase in impervious
area and restore or replace existing treatment facilities impacted by this project. This
approach was discussed with SFWMD during an interagency monthly meeting held on
September 20th 2012.
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report iii
TABLE OF CONTENTS
SECTION PAGE
EXECUTIVE SUMMARY ............................................................................................ ii
TABLE OF CONTENTS .............................................................................................. iii
LIST OF TABLES ..................................................................................................... vi
1. INTRODUCTION ................................................................................................. 1
1.1 Project Description and Location .................................................................... 1
2. DATA COLLECTION ............................................................................................ 2
2.1 Vertical Datum ............................................................................................ 2
2.2 Regional Watershed and Receiving Waterbodies ............................................... 2
2.3 Seasonal High Ground Water Table ................................................................. 3
2.4 Soil Properties ............................................................................................. 4
2.5 Wellfields .................................................................................................... 5
2.6 Existing Drainage Concerns ........................................................................... 5
3. DESIGN CRITERIA ............................................................................................. 6
3.1 Standards ................................................................................................... 6
3.2 Water Quality .............................................................................................. 8
3.3 Discharge Limitations ................................................................................. 10
4. PRELIMINARY DRAINAGE ANALYSIS ............................................................... 11
4.1 Stormwater Management Systems ............................................................... 11
4.2 System C8_I95-S ...................................................................................... 12
4.2.1 Existing Condition ............................................................................ 12
4.2.2 Ultimate Build Alternative ................................................................. 13
4.2.3 Interim Build Alternatives ................................................................. 14
4.3 System C8_PR ........................................................................................... 15
4.3.1 Existing Condition ............................................................................ 15
4.3.2 Ultimate Build Alternative ................................................................. 16
4.3.3 Interim Build Alternatives ................................................................. 16
4.4 System C8_GGI ......................................................................................... 17
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report iv
4.4.1 Existing Condition ............................................................................ 17
4.4.2 Ultimate Build Alternative ................................................................. 18
4.4.3 Interim Build Alternatives ................................................................. 19
4.5 System C8_I95-N ...................................................................................... 20
4.5.1 Existing Condition ............................................................................ 20
4.5.2 Ultimate Build Alternative ................................................................. 21
4.5.3 Interim Build Alternatives ................................................................. 21
4.6 System C9_GGI ......................................................................................... 22
4.6.1 Existing Condition ............................................................................ 22
4.6.2 Ultimate Build Alternative ................................................................. 23
4.6.3 Interim Build Alternatives ................................................................. 24
4.7 System C9_TPK ......................................................................................... 25
4.7.1 Existing Condition ............................................................................ 25
4.7.2 Ultimate Build Alternative ................................................................. 25
4.7.3 Interim Build Alternatives ................................................................. 26
4.8 System C8_NW17th ................................................................................... 27
4.8.1 Existing Condition ............................................................................ 27
4.8.2 Ultimate Build Alternative ................................................................. 27
4.8.3 Interim Build Alternatives ................................................................. 27
4.9 Drainage Analysis Summary ........................................................................ 29
5. FLOODPLAIN ................................................................................................... 31
6. CROSS DRAINS ................................................................................................ 32
7. WATERBODY CROSSINGS ................................................................................ 32
7.1 I-95 over C-8 Canal (Bridge No. 870348) ...................................................... 32
7.2 NW 167th Street over NW 17th Avenue Canal (Culvert Extension) ...................... 33
7.3 NW 165th Street over NW 17th Avenue Canal (Proposed Culvert) ....................... 34
8. PERMITTING ................................................................................................... 35
8.1 Existing Permits ......................................................................................... 35
8.2 Proposed Permits ....................................................................................... 37
9. CONCLUSIONS ................................................................................................. 37
10. REFERENCES ................................................................................................... 38
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report v
LIST OF FIGURES
FIGURE PAGE
Figure 1-1 Project Location ........................................................................................ 1
Figure 2-1 Regional Watersheds ................................................................................. 3
Figure 3-1 Anodyne Superfund Site Contamination Plume & Buffer ................................ 10
Figure 4-1 Stormwater Management Systems ............................................................ 12
Figure 4-2 Drainage System C8_I95-S ...................................................................... 13
Figure 4-3 Drainage System C8_PR .......................................................................... 15
Figure 4-4 Drainage System C8_GGI ........................................................................ 18
Figure 4-5 Drainage System C8_I95-N ...................................................................... 20
Figure 4-6 Drainage System C9_GGI ........................................................................ 22
Figure 4-7 Drainage System C9_TPK ........................................................................ 26
Figure 4-8 Drainage System C8_NW17th ................................................................... 28
Figure 5-1 FEMA Floodplain Map ............................................................................... 31
Figure 7-1 Bridge No. 870348 (I-95 over C-8 Canal) ................................................... 33
Figure 7-2 Culvert Extension (NW 167th ST Over NW 17th Ave. Canal) ............................ 34
Figure 7-3 Proposed Culvert (NW 165th ST Over NW 17th Ave. Canal) ........................... 35
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report vi
LIST OF TABLES
TABLE PAGE
Table 2-1 Datum Conversion from NGVD 29 to NAVD 88 ............................................... 2
Table 2-2 Percolation Rates within Project Area ............................................................ 4
Table 2-3 Soil Corrosion Properties ............................................................................. 4
Table 2-4 Miami-Dade County Soil Types within Project Area .......................................... 5
Table 3-1 Design Criteria .......................................................................................... 6
Table 3-3 SFWMD Water Quality ................................................................................ 9
Table 4-1 Drainage System Characteristics ................................................................ 29
Table 4-2 Preliminary Calculation Summary ............................................................... 30
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report vii
LIST OF APPENDICES
Appendix A: Figures and Maps
A-1: Project Aerial
A-2: USGS Quad Map
A-3: NRCS Soil Survey Maps
A-4: Miami-Dade County Average October Ground Water Level Map
A-5: Miami-Dade County Wellfield Map
A-6: FEMA Flood Insurance Rate Map
A-7: Vertical Datum Conversion
Appendix B: Calculations
B-1: Drainage Areas
B-2: Water Quality Treatment Calculations
B-3: Water Quality Impact Evaluation
Appendix C: Project Correspondence and Meeting Minutes
C-1: RER exemption email January 13th 2012
C-2: SFWMD Interagency Meeting April 19th 2012
C-3: SFWMD Interagency Meeting September 20th 2012
C-4: RER Meeting October 15th 2012
C-5: FDOT Maintenance Teleconference October 24th 2012
Appendix D: Geotechnical Data
D-1: Geotech Structural Report Excerpts
D-2: Geotech Percolation and Infiltration Report
Appendix E: Excerpts from Previous Projects
E-1: Drainage Map from SPN 87270-3418
E-2: Drainage Map from SPN 87270-3906
E-3: Drainage Map from SPN 87270-3454
E-4: Drainage Report from SPN 87270-3419
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report viii
Appendix E: Excerpts from Previous Projects (Continued)
E-5: Drainage Report from FPID 422796-2-52-01
E-6: Drainage Plans from SPN 87270-3451
E-7: Drainage Plans from FPID 415462-2-52-02
Appendix F: Excerpts from Previous Permits
F-1: SFWMD Permit 85-00070-S, Application X000013200
F-2: SFWMD Permit 85-00070-S, Application 090225-2
F-3: SFWMD Permit 13-01013-P, Application 070314-4
F-4: DERM Permit OF 401
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report 1
1. INTRODUCTION
This report provides the drainage documentation required to support the Project
Development and Environment (PD&E) Study prepared for the Golden Glades Interchange
(GGI) project area. Possible locations for stormwater treatment ponds, Right-of-Way (R/W)
needed to accommodate the stormwater management facilities and a preliminary hydraulic
analysis of the area are contained in this report.
1.1 Project Description and Location
The purpose of this project is to provide a system-to-system connection for the
SR 826/Palmetto Expressway eastbound to I-95 northbound movement and to improve the
Turnpike southbound to I-95 southbound connection. The ultimate phase will evaluate a
system-to-system connection between new express lanes on SR 826/Palmetto Expressway
and the existing I-95 Express Lanes system. The Golden Glades Interchange (GGI) is
located in northeastern Miami-Dade County, Florida (See Figure 1-1). The study area
covers approximately 512 Acres and is located in Section 13, Township 52 South and Range
41 East. A USGS quadrangle map of the study corridor is located in Appendix A.
Figure 1-1 Project Location
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report 2
2. DATA COLLECTION
2.1 Vertical Datum
The primary vertical datum used in this report and the calculations is NGVD 29. This datum
was chosen due to the fact that all existing data for the interchange is in NGVD 29.
Moreover, government agencies such as the Army Corps of Engineers (ACOE), Federal
Emergency Management Agency (FEMA), South Florida Water Management District
(SFWMD) and Miami-Dade Department of Regulatory and Economic Resources (RER)
currently use NGVD 29. Where practical, elevations are shown in both NGVD 29 and NAVD
88 since NAVD 88 is the Florida Department of Transportation (FDOT) standard datum. The
vertical datum shift was identified for the approximate centroid of the study area by using
the National Geodetic Survey VERTCON online tool. Coordinates of the centroid are shown
below in Table 2-1. The datum shift used to convert NGVD 29 to NAVD 88 within the study
area is (-)1.562 feet. See Appendix A for National Geodetic Survey VERTCON datum shift.
Table 2—1: Datum Conversion from NGVD 29 to NAVD 88
Location Latitude Longitude Shift (ft)
Study Area Centroid 25° 55’ 40” 80° 12’ 37” (-)1.562
2.2 Regional Watershed and Receiving Waterbodies
The study corridor lies within South Florida Water Management District (SFWMD) Basins
C-7, C-8, and C-9 East (See Figure 2-1). Discharge from the study area is bifurcated by
the South Florida Rail Corridor (SFRC). Runoff from the area north of the SFRC ultimately
drains northwesterly, within the Turnpike swales, towards the C-9 Canal. The area south of
the SFRC generally drains south, within 2-72” asphalt coated ultra-flow metal pipes under
I-95, towards the C-8 Canal. An exception to this statement is the southwestern corner of
the project, which is north of the SFRC but drains into a local canal that runs along NW 17th
Avenue and discharges into the C-8 Canal.
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report 3
Figure 2-1 Regional Watersheds
2.3 Seasonal High Ground Water Table
Geotechnical information provided by HR Engineering Services states that test borings,
conducted during 2012, showed groundwater levels varying from elevation 2.1 to 2.6 ft-
NGVD 29 (0.5 to 1.0 ft-NAVD 88). The geotechnical report recommended a Seasonal High
Ground Water Table (SHGWT) of 4.6 ft-NGVD 29 (3.0 ft-NAVD 88). A review of the
Miami-Dade County Design Standards indicates that the average elevation of the October
ground water table for the project area is approximately 2.5 ft-NGVD (0.9 ft-NAVD). As
such, the SHGWT value of 4.6 ft-NGVD 29, recommended by the geotech report, is
considered conservative and will be used in the preliminary drainage design for this study.
See Appendix D for the geotech reports and Appendix A for Miami-Dade County average
October ground water level.
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report 4
2.4 Soil Properties
Five percolation tests (Exfiltration) and seven double ring infiltrometer tests (Infiltration)
were performed, during the geotechnical exploration, to estimate the hydraulic conductivity
of the soils within the project area. Two additional percolation tests, from the nearby
Turnpike Connector project, were also provided in the geotechnical report. Test results
indicate that the percolation rates are poor to moderate and increase with depth, as shown
in Table 2-2. The effective infiltration rate varies from 0.04 to 3.5 inches/hour for an
average of 1.5 inches/hour. Calculations conducted to support the preliminary drainage
analysis described in this report consider exfiltration trenches to be installed at a depth of
20-ft having a hydraulic conductivity of 1.5E-05 cfs/ft2-ft of head. Dry-retention pond
recovery will be estimated using an infiltration rate of 1.5 inches/hour. These values were
chosen as they are expected to yield reasonably conservative results.
Table 2—2: Percolation Rates within Project Area
Depth (ft) Hydraulic Conductivity (cfs/ft2-ft of head)
0 - 10 2.6E-06 to 3.2E-04
10 - 15 1.6E-06 to 2.3E-03
15 - 20 1.7E-05 to 2.4E-04
As an element of the geotechnical evaluation, soil and water samples were obtained to
identify the soil corrosion properties outlined in Table 2-3. Testing of the soil and water
samples revealed that drainage culverts will be subject to a moderately aggressive
environment.
Table 2—3: Soil Corrosion Properties
Resistivity (ohms-cm) pH Sulfates
(ppm) Chlorides
(ppm)
1,460-3,860 7.3-7.8 9-61 4-12
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report 5
The geotechnical report for this project suggests that unsuitable materials are not
anticipated within the project area based on a review of the soil map published by the
United States Department of Agriculture (USDA). There are four general mapping units (soil
types), as shown below in Table 2-4. See Appendix D for the geotech reports and
Appendix A for the project soils map.
Table 2—4: Miami-Dade County Soil Types within Project Area
Map Unit
Symbol Map Unit Name Typical Profile
10 Udorthents, limestone substratum-
Urban land
0 to 55 inches: Extremely Gravely Loam
55 to 59 inches: Unweathered Bedrock
15 Urban land N/A
40 Pomello sand 0 to 80 inches: Sand
99 Water 100 percent Water
2.5 Wellfields
There are no wellfields within the project area. See Appendix A for a wellfield map of
Miami-Dade County.
2.6 Existing Drainage Concerns
The Study Team contacted FDOT District Six maintenance personnel to discuss maintenance
concerns as they relate to drainage. Items of particular concern were localized ponding in
the swales/infields or flooding in the travel lanes. Based on information obtained, incidents
of flooding have been reported at the NW 7th Avenue extension to US 441. Flooding at this
location has been reported as early as 2004 and as late as 2010. Most of the flooding
issues seem to be attributed to deficiencies in the drainage system as well as clogged
drainage inlets. See teleconference notes and correspondence located in Appendix C.
FDOT District Six drainage personnel have been made aware of the reoccurring ponding
taking place at the NW 7th Avenue extension to US 441. During the Final Design stage of
this project, drainage design engineers are advised to further explore existing flooding
conditions to ensure that they are corrected as part of the interim improvements proposed
for the interchange.
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report 6
3. DESIGN CRITERIA
3.1 Standards
Drainage design and construction criteria for the proposed improvements will adhere to
FDOT Standards for the design of such roadways and will comply with the recommended
standard practices as set forth in Table 3-1.
Table 3—1 Design Criteria
DESIGN ELEMENT CRITERIA SOURCE
Design Frequency
Storm Sewer
- 10-Year design frequency standard (1, 8, 24-hour)
- Check 100-Year storm (1,8, 24 hour)
- 50-Year design frequency for interstate facility sag
vertical curves which have no outlet other than a
storm drain system
D.M. Section 3.3
Cross Drains 50-Year design frequency D.M. Section 4.3
Design Tailwater
All Conditions Conditions vary with outfall D.M. Section 3.4
Time Of Concentration (TOC) Minimum T.O.C. of 10 Minutes
Other T.O.C calculations to follow NRCS TR-55 D.M. Section 3.5.1
Pipe Slopes
Minimum Min. slope to produce v=2.5 ft/sec flowing full D.M. Section 3.6.1
Manning's "n" Coefficient
Pipes 0.012 (smooth pipes) 0.024 (corrugated pipe) D.M. Section 3.6.4
Asphalt (rough texture) 0.016 Asphalt Pavement S.D. Table 3-2
Grades
Longitudinal Gutter Grade minimum gutter grade is 0.3% D.M. Section 3.8.1
Spread Standards
Design Speed ≤ 45 Keep ½ lane clear D.M. Section 3.9
45 < Design Speed ≤ 55 Keep 8-ft of lane clear
Design Speed >55 No encroachment
Pipe Size And Length
Trunk Line 18-in Minimum Diameter. D.M. Section 3.10.1
Length Between Structure 18-in Pipe=300ft., 24in – 36in=400ft,>42-in =500ft D.M. Section 3.10.1
Exfiltration Trench
Pipe Diameter 24-in minimum D.M. Section 3.10.1
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report 7
Table 3—1 Design Criteria
DESIGN ELEMENT CRITERIA SOURCE
Exfiltration Trench (continued)
Pipe Lengths
Access through both ends: 300-ft 24-in to 30-in pipes;
400-ft for 36-in and larger pipes.
Access through only one end: 150ft 24-in to 30-in
pipes; 200-ft 36-in and larger pipes
D.M. 3.10.1
Pipe Perforations Perforated pipes preferred in District 6
E.T.R.M Section 3.1
Skimmers/Baffles Required at each entrance to exfiltration trench
Trench Width Minimum 4-ft , maximum 8-ft
Trench Depth Maximum of 20-ft
Drainage Structures 2-foot sediment sump for inlets and catch basins
Other District 6 Preferences FDOT District 6 Exfiltration Trench Reference Manual
Ground Water Clearance
Dry Retention Pond bottom minimum 1-ft above SHGWT B.M.P. Section VIII
Freeboard
Storm Drain
Hydraulic Gradeline Minimum 1-ft below theoretical
gutter elevation
1.13-ft below E.O.P. for Types E & F curb and gutter
1-ft below grate elevation for inlets Standard Index,
S.D. Section 5.0
Ponds Minimum 1-ft above peak design stage, measured
from the inside edge of the maintenance berm.
D.M. Section 5.3.4.2
Permanent Pool Pond Depth
Wet Detention 4-ft minimum depth, 8-ft maximum depth S.M.F. Section 3.1.1
Stormwater Management System
Water Quality Water quality standards, as set forth in Chapter 62-
302, Florida Administrative Code. V - IV Section 5.0
Discharge Limitations Historic Discharges, Post <= Pre V - IV Section 6.1
Bridge Clearances
Horizontal Center span – 25 feet clear bent spacing, measured
perpendicular to the channel.
Approach bents – 20 feet between faces of bents. V - V Section IX B
Vertical
6 feet above seasonal high optimum water control
elevation, or 2 feet above the design water surface,
whichever produces the greater elevation.
7 feet above mean high water for Miami-Dade Canals RER Meeting 10/15/2012
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report 8
Table 3—1 Design Criteria
DESIGN ELEMENT CRITERIA SOURCE
Bridge Clearances (continued)
Vertical 2 feet minimum clearance between design flood stage
and the low member of bridge to allow for debris
passage. 6 feet above Normal High Water for
controlled canals
P.P.M. 2.10.1
Abbreviations
D.M. FDOT Drainage Manual; January 2013
E.T.R.M FDOT District 6 Exfiltration Trench Reference Manual; January 2008
P.P.M. Plans Preparation Manual Volume 1, January 2012
S.D. FDOT Storm Drain Handbook; January 2012
S.M.F. FDOT Stormwater Management Facility Handbook; January 2004
V-IV SFWMD Permit Information Manual Volume IV; 2012
V-V SFWMD Permit Information Manual Volume V; 1999
B.M.P SFWMD Best Management Practices for South Florida Urban Stormwater Management Systems; April 2002
3.2 Water Quality
Stormwater management systems proposed by this study meet existing water quality
standards as set forth in Chapter 62-302 of the Florida Administrative Code. The approach
to meeting water quality requirements is to provide treatment for the increase in impervious
area and restore or replace existing permitted treatment facilities impacted by this project.
Table 3-2 summarizes the methodology used to calculate the treatment volume. An
emphasis was placed on providing treatment for the increase in impervious area rather than
providing treatment for the entire project area since the project is geometrically constrained
due to the linear nature of the facility and heavily urbanized areas surrounding the study
area. This approach will be followed for the increase in impervious area as it relates to the
total project area and not dependent on whether the increase in impervious area is due to
roadway widening or total road reconstruction, as discussed in the South Florida Water
Management District (SFWMD) interagency monthly meeting held on September 20th 2012.
See Appendix C for meeting minutes.
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report 9
Table 3—2: SFWMD Water Quality
Type of Treatment Treatment Volume*
Wet-detention 2.5 inches times the increase in impervious area
Dry-detention 75% of wet detention volume
Dry-retention 50% of wet detention volume
*Note: SFWMD agreed to this approach due to corridor constraints.
During the development of the Contamination Screening Evaluation Report (CSER) for this
PD&E, a superfund site named Anodyne was identified. There is evidence that waste from
this site was discharged directly onto the ground. Furthermore, a 90-foot deep injection
well was allegedly used to dispose of spent solvents during the manufacturing phase of the
facility’s operation. The Anodyne contamination plume, as estimated in 2010 by the
TerranearPMC groundwater remediation study, extends into the western portion of the
study corridor. A one-mile buffer around the contamination plume covers most of the study
area, as shown below in Figure 3-1. The Florida Department of Environmental protection
(FDEP) discourages the use of wet ponds or exfiltration trenches within one mile of a
superfund site. As such, this study proposes dry-retention and/or dry-detention stormwater
treatment facilities for areas which fall within the 1-mile Anodyne buffer. The use of solid
pipe is FDEP’s preferred method of conveyance through contaminated areas. A Phase II
contamination study is recommended by the CSER to further quantify impacts to the project
due to the contamination from the Anodyne superfund site as well as other smaller
contamination sites within the study area. The CSER is prepared as part of the PD&E Study.
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report 10
Figure 3-1 Anodyne Superfund Site Contamination Plume & Buffer
3.3 Discharge Limitations
As mentioned earlier in Section 2.2, the main receiving water bodies for this project are
the C-8 and C-9 Canals. According to the South Florida Water Management District
(SFWMD) Permit Information Manual, Volume IV, the allowable off-site discharge is
essentially unlimited by gravity connection for both the C-8 and C-9 Canals. Given the
preliminary nature of this study, the post development peak discharge has been attenuated
to predevelopment levels in order to avoid impacting adjacent land uses. This is particularly
important for systems discharging into the C-9 Canal, which must first flow through the
Turnpike’s existing system. The peak discharge for this project was estimated by using the
SCS runoff curve number method as described in Technical Release 55 (TR-55), published in
1986 by the United States Department of Agriculture (USDA).
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report 11
4. PRELIMINARY DRAINAGE ANALYSIS
The preliminary drainage analysis conducted for this study consisted of evaluating the
project area to estimate the stormwater treatment and conveyance needs. The term
stormwater treatment is used throughout this section to refer to both the water quality and
peak attenuation requirements for a particular system. Typically the greater of the two is
provided to insure both requirements are met. Preliminary calculations show that for most
of the drainage systems in this project, the water quality and peak attenuation
requirements are very close. Preliminary calculations are located in Appendix B.
A summary of the analysis is provided in this Section. It follows the general format of
identifying existing conditions and then providing recommended improvements that would
be needed to accommodate additional runoff expected from the increase in impervious area
(pavement) in the post development condition. The analysis was conducted for the
roadway Ultimate Build Alternative and Interim Build Alternatives 3A, 3B, 3C, and 4 as
described in the Preliminary Engineering Report.
4.1 Stormwater Management Systems
The project area was divided into six main drainage systems, as shown below in
Figure 4-1. A seventh system around NW 17th Street was delineated based on potential
connectivity mitigations to SR 826/Palmetto Expressway; this is further explained in
Section 4.8. System limits were determined using existing drainage divides, which included
changes in elevation, transportation facilities and water bodies. The naming convention was
chosen so that the first two characters represent the receiving water body followed by an
abbreviation of the general location of the system. These systems combined have a total
area of 310 Acres.
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report 12
Figure 4-1 Stormwater Management Systems
4.2 System C8_I95-S
4.2.1 Existing Condition
System C8_I95-S covers the area of I-95 between SR 916/NW 135th Street/Opa-Locka
Boulevard and the C-8 Canal. It is slightly over a mile long and within the 1-mile buffer of
the Anodyne contamination plume. Most of the drainage system consists of a network of
inlets and closed pipes connecting to a main outfall trunk line, which discharges into the C-8
Canal. There is, nonetheless, a segment of the southbound lanes, between NW 151st Street
and the C-8 canal, which has a small swale system with a 24-inch outfall pipe into the
canal. The main outfall trunk line in this system consists of concrete culverts, which
progress in size from 30-inch to 42-inch. The trunk line runs the length of the basin and is
on the west side of I-95 from Opa-Locka Boulevard to just south of NW 151st Street. It then
crosses under I-95 to connect to a 54-inch trunk line running east towards the canal. A
desktop review of the limited plans available for the area indicates that the 54-inch trunk
line services both I-95 and the adjacent residential community. The existing stormwater
management system, for this segment of I-95, appears to be a direct discharge system with
no formal water treatment being provided.
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report 13
Figure 4-2 Drainage System C8_I95-S
4.2.2 Ultimate Build Alternative
Most of the proposed roadway work within Drainage System C8_I95-S, under the Ultimate
Build Alternative, is focused on the southbound lanes of I-95. Impervious area (pavement)
is being added in order to provide direct managed lane connections between Florida’s
Turnpike and I-95 Express southbound managed lanes. The new pavement will add
2.0 Acres of impervious area and increase the roadway footprint towards the west.
Preliminary calculations indicate that 0.21 Ac-ft of additional dry-retention will be needed to
meet water quality requirements. Several parcels, in the vicinity of NW 6th Court between
NW 146th Street and NW 151st, will be acquired to accommodate the roadway
improvements. A review of the proposed roadway geometry suggests that 1.8 Acres will be
available for storm water treatment in the area where parcels will be acquired. This area
can be used to accommodate a dry-retention pond with a bottom area of 1.2 Acres and a
depth of 1.0 ft to provide a dry-retention treatment volume of 1.2 Ac-ft. The pond would
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report 14
provide 1.0 Ac-ft of surplus treatment since only 0.2 Ac-ft of treatment is required for this
system. Surplus treatment provided in this pond could be used to compensate for required
treatment in adjacent systems that also outfall into the C-8 Canal. This pond will need to
be connected to the system trunk line in order to provide an outfall for overflows into the
pond. A connection will have to be made to the trunk line before it crosses to the east side
of I-95 in order to avoid needing to Jack & Bore or needing to open trenching across both
lanes of I-95. It is anticipated that the surface drainage for the roadway can be
accomplished by extending the existing closed pipe system and placing inlets as needed to
control the spread. A note is made that contamination has been identified in the general
vicinity of the proposed dry-retention pond. The site is identified as Jimmy’s Shell located
at 14601 NW 7th Avenue and it poses a minimal potential of environmental impacts if
dewatering is needed during construction activities. See environmental documents for
specific contamination issues along the corridor.
4.2.3 Interim Build Alternatives
Under Build Alternative 3A, there is minor work occurring within Drainage System C8_I95.
The increase in impervious area is limited to the southbound lanes of I-95 between
NW 151st Street and the C-8 Canal. Preliminary calculations indicate that the impervious
area will increase by 0.4 Acres and will require 0.04 Ac-ft of dry-retention. This amount of
treatment is small enough that it can easily be accommodated in an adjacent system. In
the event that surplus treatment is not available in a nearby system, a small dry-retention
pond can be placed in the western swale of I-95, just north of NW 151st Street, to provide
the required water quality treatment. The western swale can accommodate a dry retention
pond with a bottom area of 0.3 Acres and retention depth of 1-ft to provide a dry-retention
treatment volume of 0.3 Ac-ft. Overflows into the pond can be discharged by using a
control structure connected to the existing 24-inch outfall pipe, which discharges into the
C-8 Canal.
Under Build Alternatives 3B and 3C, the proposed improvements are the same, within this
system, as in the Ultimate Build Alternative. As such, drainage improvements needed to
meet water quality requirements for Build Alternatives 3B and 3C are the same as what is
needed for the Ultimate Build Alternative in this drainage system.
For Build Alternative 4, the proposed improvements and added impervious area are the
same, within this system, as in Build Alternative 3A.
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report 15
4.3 System C8_PR
4.3.1 Existing Condition
System C8_PR consists of the Park & Ride, Municipal Parking facility and SR 9. The system
is bound by the South Florida Rail Corridor (SFRC) on the north and the Turnpike Connector
on the east, as shown in Figure 4-3. It is partially within the Anodyne contamination
plume and completely within the 1-mile buffer of the plume. Stormwater runoff from this
system is generally conveyed southeasterly through the Municipal Parking facility’s piped
drainage system. Ultimately, the runoff is discharged through a 42-inch culvert into the
adjacent drainage system (C8_GGI), which outfalls into the C-8 Canal. See Appendix E for
the Municipal Parking Facility drainage map (SPN 87270-3454-414). The existing
stormwater management system appears to be a direct discharge system with no formal
water treatment being provided.
Figure 4-3 Drainage System C8_PR
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report 16
4.3.2 Ultimate Build Alternative
Roadway improvements proposed within Drainage System C8_PR, under the Ultimate Build
Alternative, are geared towards providing a direct connection between SR 9 and I-95 in the
northbound direction as well as widening the I-95 connector to facilitate movements from
the Turnpike and SR 826 onto I-95 southbound. The new pavement will add 2.3 Acres of
impervious area. Preliminary calculations indicate that 0.24 Ac-ft of dry-retention will be
needed to meet water quality requirements. The required treatment can be provided
through compensation in System C8_I95, which outfalls into the same receiving water body
and is anticipated to have surplus treatment capacity when the Ultimate Build Alternative is
constructed. In the event that surplus treatment is not available in C8_I95 or a nearby
system, a 1-ft ditch block can be provided before runoff enters the Municipal Parking
facility’s piped drainage system. This would result in the retention of runoff within the
southbound and northbound lanes of SR-9. Two small dry-retention ponds would be created
that would have a combined bottom area of 1.6 Acres and a treatment volume of 1.6 Ac-ft,
which exceeds the treatment volume of 0.24 Ac-ft required for this drainage system.
A surplus of 1.36 Ac-ft would be available to be used as compensation in an adjacent
system. Excess runoff into the ponds would overtop the ditch block and outfall through the
Municipal Parking facility’s piped drainage system. The minor stage, created in the
retention ponds, is not anticipated to impact the existing roadway base clearance since the
roads in this area are several feet above the existing ground level.
4.3.3 Interim Build Alternatives
Within Drainage System C8_PR, Interim Build Alternatives 3A, 3B and 3C will widen the
Turnpike connector. Interim Build Alternative 3A will add 1.9 Acres of impervious area and
require 0.20 Ac-ft of dry-retention while both Interim Build Alternatives 3B and 3C will add
2.2 Acres of impervious area and require 0.23 Ac-ft of dry-retention. For Build Alternative
4, the proposed improvements and added impervious area are the same, within this system,
as in Build Alternative 3A. In all cases, the potential stormwater treatment methods
described for the Ultimate Build Alternative are applicable. Namely, using surplus treatment
in an adjacent drainage system or providing a 1-ft ditch block to create a treatment volume
of 1.6 Ac-ft.
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report 17
4.4 System C8_GGI
4.4.1 Existing Condition
System C8_GGI consists of the southern part of the Golden Glades Interchange (GGI). The
system is bound by the South Florida Rail Corridor (SFRC) on the north and the C-8 Canal
on the south, as shown in Figure 4-4. Most of this drainage system is within the 1-mile
buffer of the Anodyne contamination plume. This drainage system receives runoff from
System C8_PR as described in Section 4.3.1. A review of available plans and permit
information indicates that stormwater in this system is being collected and treated via
dry-retention in the various infield areas between ramps before being discharged to the
C-8 Canal.
The I-95 northern segment of this drainage system has two concrete storm sewer trunk
lines, which direct runoff south towards the GGI infield areas. One trunk line is located
under each of the outside shoulders. Both trunk lines begin as an 18-inch round culvert
near the northern limits of the drainage system and transition through several sizes of
elliptical pipe before discharging into the GGI areas. The trunk line, located under the
northbound outside shoulder ends as a 54-inch round culvert near NW 2nd Avenue while the
trunk line under the southbound outside lane ends as a 36-inch round culvert near the
infield area between I-95 and SR 9. Excess runoff generated within the interchange portion
of the system is generally conveyed south towards a double 72-inch asphalt coated metal
trunk line that is located under the southbound shoulder of I-95 between the Park & Ride
ramp and the C-8 Canal. See the drainage map for State Project 87270-3418
(Appendix E) for more information on the existing trunk lines.
The drainage report submitted to the Miami-Dade Department of Regulatory and Economic
Resources (RER), to obtain permit OF 401 for project 87270-3419, states that 15.97 Ac-ft of
retention/detention is being provided in the aforementioned infield areas. Improvements
that have occurred in this drainage system, since the RER permit was issued, have had little
impacts to the amount of impervious area or treatment volume. See Appendix F for
permit excerpts.
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report 18
Figure 4-4 Drainage System C8_GGI
4.4.2 Ultimate Build Alternative
Proposed roadway improvements within Drainage System C8_GGI, under the Ultimate Build
Alternative, facilitate connections between the major roadways within this drainage system.
A new flyover ramp to connect SR 826 eastbound to I-95 northbound as well as various
widening and roadway realignments are being provided to meet this goal. The Ultimate
Build Alternative will add 6.0 Acres of impervious area to the drainage system. This will
require 0.63 Ac-ft of dry-retention to meet water quality. In the southern end of the
project, improvements to the I-95 southbound lanes will move the travel lanes towards the
west, which will result in the double 72-inch outfall pipes, and corresponding manholes,
being in the travel lanes. Relocation of the double 72-inch outfall pipes (appx. 1,400-ft) is
recommended to avoid having manholes in the travel lanes. Likewise, in the northern end
of the drainage system, a portion of the 54-inch trunk line (appx. 2,800-ft) will also need to
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report 19
be relocated for the same reason since the I-95 northbound lanes will be shifted towards
the east to create a median area that will accommodate the managed lanes.
The control elevation for one of the existing dry-ponds, near the proposed flyover ramp, can
be raised by 0.5-ft to increase the treatment volume from 0.95 Ac-ft to 1.67 Ac-ft in order
to provide 0.72 Ac-ft of treatment volume, exceeding the required volume needed. The dry
pond is identified as Area 20 in the plans for project 87270-3419. A ditch block is currently
being used to provide the control elevation. It can be raised by adding more earth to the
ditch block and providing a concrete topping per SFWMD requirements. During final design,
a detailed infiltration analysis will be required to ensure the pond recovers within 24-hours
using the in-situ soil since an exfiltration trench to aid in pond recovery will not be allowed
because the dry pond is within the Anodyne 1-mile buffer. The roadway base clearance is
not anticipated to be impacted by the minor stage increase in Area 20.
An alternative approach to meet water quality requirements for this drainage system, under
the Ultimate Build Alternative, is to provide a dry retention pond within the infield area that
will be created between NW 7th Ave and the I-95 ramp. This approach would require a
careful review of existing contamination since the adjacent parcels in this area are currently
industrial. Should contamination be identified in the immediate area, a dry retention pond
poses a potential of displacing the contamination plume.
4.4.3 Interim Build Alternatives
Within Drainage System C8_GGI, Interim Build Alternatives 3A, 3B, 3C, and 4 will add 0.4,
1.1, 3.6, and 1.0 Acres of impervious area, respectively. Interim Build Alternative 3A will
require 0.04 Ac-ft of dry retention. This small amount of treatment can easily be
accommodated in a nearby drainage system. Interim Build Alternatives 3B, 3C, and 4 will
require dry-retention treatment of 0.13, 0.38, and 0.13 Ac-ft respectively. The drainage
solutions discussed in Section 4.4.2 to meet water quality requirements for the Ultimate
Build Alternative would be applicable to Build Alternatives 3B, 3C, and 4. Any surplus
storage created during these interim phases would be available for the Ultimate Build
Alternative. All four Interim Build Alternatives would require the relocation of the double
72-inch outfall pipes, located in the southern end of the drainage system.
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report 20
4.5 System C8_I95-N
4.5.1 Existing Condition
System C8_I95-N spans from just south of NE 1st Avenue to NE 183rd Street (Miami Gardens
Drive). It is slightly less than a mile long and is outside of the Anodyne 1-mile buffer. This
drainage system consists of roadside swales on both sides of the roadway with equalizer
pipes connecting them and a retention area located in the western swale where I-95 turns
away from the South Florida Rail Corridor (SFRC). The retention area provides 0.35 Ac-ft of
dry-retention treatment. See the drainage report excerpts from FPID 422796-2-52-01,
located in Appendix E for more information on the existing retention area. In general
runoff is conveyed from the eastern swale to the western swale, which abuts the SFRC, and
runs south towards Drainage System C8_GGI. A note is made that the drainage report for
FPID 422796-2-52-01 states that the area served by this drainage system ultimately
discharges to the C-9 Canal; however a review of existing plans did not show a connection
to move runoff across NE 183rd Street. As such, the study team concluded that this
drainage system ultimately discharges south along the SFRC swale towards the C-8 Canal
rather than across NE 183rd Street towards the C-9 Canal.
Figure 4-5 Drainage System C8_I95-N
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report 21
4.5.2 Ultimate Build Alternative
Under the Ultimate Build Alternative, within Drainage System C8_I95-N, proposed roadway
improvements provide an additional lane in each direction for the I-95 express lanes located
between the northbound and southbound lanes of the I-95 mainline. The express lanes are
accommodated by shifting out the mainline by approximately 14-ft on the west side and
19-ft on the east side. The Ultimate Build Alternative will add 2.2 Acres of impervious area
to the drainage system. In order to meet water quality, 0.23 Ac-ft of dry-retention will be
needed to account for the increase in impervious area and 0.18 Ac-ft will be needed to
offset encroachments into the existing retention area for a total of 0.41 Ac-ft of
dry-retention needed for this drainage system. Proposed roadway improvements will
greatly reduce or eliminate the existing swales being used for conveyance. A drainage trunk
line (appx. 2,500-ft of 42-inch) will be needed to replace the function of the swales.
Preliminary calculations indicate that the required 0.41-Ac-ft of dry-retention can be
provided by installing 2,000-ft of 20-ft deep exfiltration trench in series with the new trunk
line. The use of exfiltration trench in this drainage basin is acceptable because there is
limited R/W available for a dry pond, the drainage system is outside of the 1-mile Anodyne
contamination buffer and the anticipated exfiltration rate is 1.7E-05 cfs/ft2-ft of head.
A note is made that this basin is located near several isolated contaminated sites, according
to RER and FDEP records. See the Contamination Screening Evaluation Report (CSER) for
details of these sites.
4.5.3 Interim Build Alternatives
Interim Build Alternatives 3A, 3B, 3C, and 4 will not add any additional impervious area to
Drainage System C8_I95-N. As such, no improvements are needed to this drainage system
under the interim build alternatives.
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report 22
4.6 System C9_GGI
4.6.1 Existing Condition
System C9_GGI consists of the northern part of the Golden Glades Interchange (GGI) and
an adjacent section of SR 826 (Palmetto Expressway), as shown in Figure 4-6. It is
partially within the Anodyne contamination plume and completely within the 1-mile buffer of
the plume. Stormwater runoff from the SR 826 segment of this system is conveyed east,
through trunk lines along both sides of the roadway, towards the GGI interchange infield
area. Runoff from the SR 826 southern swale is conveyed through a 24-inch x 38-inch
cross drain under SR 826 to unite with runoff from the northern swale and flows north along
the outside western Turnpike swale. In general, runoff generated within this drainage
system is directed towards the GGI infield areas and then north towards the Turnpike
(Drainage System C9_TPK) where it is conveyed by a 36-inch culvert through the Toll Plaza
area and ultimately into the C-9 Canal. Based on a review of available construction plans
and permitting information, the existing stormwater management system was not designed
to provide a specific amount of water quality treatment.
Figure 4-6 Drainage System C9_GGI
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report 23
4.6.2 Ultimate Build Alternative
Proposed roadway improvements within Drainage System C9_GGI, under the Ultimate Build
Alternative, facilitate connections between the major roadways within this drainage system.
A new flyover ramp to connect SR 826 eastbound to I-95 northbound as well as widening of
the Turnpike connector to I-95 southbound are being provided to meet this goal. The
Ultimate Build Alternative will add 7.3 Acres of impervious area to the drainage system.
This will require 0.78 Ac-ft of dry-retention to meet water quality.
Proposed right-of-way acquisition of the warehouse area located in the Sunshine Industrial
Park found in the southwest quadrant of the Golden Glades Interchange (GGI) can provide
an appropriate location for water quality treatment. The proposed right-of-way acquisition
area is part of Interim Build Alternative 4, which will be used to provide for the NW 12th
Avenue on-ramp to SR 826 that continues connecting to I-95 southbound. This potentially
acquired area can accommodate a 4.2-Acre dry-retention pond. A depth of 0.5-ft can yield
2.10 Ac-ft of dry-retention treatment in the pond, thereby providing surplus treatment since
only 0.78 Ac-ft of treatment is required for this system. Surplus treatment provided in this
pond could be used to compensate for required treatment in adjacent systems that also
outfall into the C-9 Canal.
In order to get runoff from SR 826 to the proposed pond, trunk lines along both sides of
SR 826 will need to be extended (Appx. 1000-ft) and increased in size from 24-inch to
36-inch pipes. The north trunk line would need to cross under SR 826 and connect to the
south trunk line before reaching the SR 826/I-95 ramp. The final discharge point, of the
extended southern trunk line, would then be on the eastern side of the pond by the
SR 826/I-95 ramp. Excess runoff into the pond could be discharged using the existing
24-inch x 28-inch cross drain under SR 826 and then continue to flow north along the
outside western Turnpike swale towards the Turnpike Toll Plaza and eventually into the
C-9 Canal.
The required treatment volume for this drainage system can also be provided by creating a
dry-retention pond in the FDOT owned vacant lot, folio 34-2112-000-0083, located just
north of the railroad and bordered by both the SR 826 and Turnpike Connectors. This
vacant lot can accommodate a 3.6-Acre dry-retention pond while avoiding impacting the
Intelligent Transportation System (ITS) existing building on the site. A depth of 0.5 ft will
yield 1.80 Ac-ft of dry-retention treatment in the pond thereby providing surplus treatment
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report 24
for this system. As mentioned before, available surplus treatment could be used to
compensate for required treatment in adjacent systems that also outfall into the C-9 Canal.
The aforementioned vacant parcel has been used in the recent past as a debris staging area
to facilitate disaster recovery after hurricanes. If the parcel is used as a stormwater
treatment pond, it will no longer be available for use as a debris staging area. See
Appendix C for notes of a teleconference held with the FDOT Maintenance Department.
In order to get runoff from SR 826 to the proposed pond, trunk lines will be needed along
both sides of the roadway to get the runoff to the Turnpike Connector infield area. The
trunk line on the north side will need to cross under the SR 826 mainline with a 42-inch
culvert (Appx. 300-ft). The trunk line on the south side will need to cross under the
SR 826/I-95 ramp with a 42-inch culvert (Appx. 150-ft). A 54-inch culvert (Appx. 250-ft)
will need to be installed under the Turnpike Connector to get the runoff from the infield area
to the pond. Given the relative height of the roadways to the surrounding ground, the Jack
& Bore installation method will likely be the most economical way to install the needed
culverts. Excess runoff into the pond can be discharged using the existing culverts to
convey runoff towards the Turnpike Toll Plaza and into the C-9 Canal.
A review of plans for proposed improvements to the Turnpike Toll Plaza (FPID 415462-2-52-
02) indicates that the existing 36-inch culvert, used as this systems outfall and described in
Section 4.7.1, will remain in operation after the improvements are constructed. See
Appendix E for excerpts from the plans for the Toll Plaza improvements.
4.6.3 Interim Build Alternatives
Within Drainage System C9_GGI, Interim Build Alternatives 3A, 3B and 3C are focused on
widening the Turnpike Connector. Interim Build Alternative 4 also focuses on the Turnpike
Connector widening but is more distinctly concerned with maintaining the NW 12th St
on-ramp open, to SR 826. Interim Build Alternative 3A, 3B, 3C, and 4 will add 3.3, 3.6, 3.8,
and 3.5 Acres of impervious area, respectively. In all cases, the increase in impervious area
is roughly half of the increase estimated for the Ultimate Build Alternative. As such, the
potential stormwater treatment methods described for the Ultimate Build Alternative are
applicable. However, the dry-retention pond potentially available due to the prospective
right-of-way acquisition is only a viable treatment alternative for Interim Build Alternative 4.
A note is made that there is a potential of encountering contamination during pond
excavation due to the proximity of the Anodyne contamination plume and localized fuel
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report 25
spills from traffic accidents in the interchange. Final designers of the selected interim build
alternative may want to limit excavation of the pond to the amount needed to meet water
quality requirements for the interim design rather than excavating the pond for the Ultimate
Build Alternative.
4.7 System C9_TPK
4.7.1 Existing Condition
System C9_TPK covers the area of the Turnpike between the Toll Plaza and the Golden
Glades Interchange (GGI) loop ramps. It is approximately half a mile long and is within the
1-mile buffer of the Anodyne contamination plume. In general, runoff from this system is
conveyed along the Turnpike swales towards the C-9 Canal. This drainage system receives
runoff from Drainage System C9_GGI.
For the purposes of quantifying the increase in impervious area, the existing condition in
Drainage System C9_TPK was considered as the condition that will result once project FPID
415462-2-52-02 is constructed. A review of the proposed plans indicates that the existing
36-inch culvert, used as this system’s outfall, will remain in operation after the
improvements are constructed. See Appendix E for excerpts from the plans for the Toll
Plaza improvements.
Project FPID 415462-2-52-02 will convert the Toll Plaza to an All Electronic Tolling (AET)
facility. Consequently, the facility’s impervious footprint will be reduced allowing water
quality treatment to be provided in the roadside swales. Documentation for permit
13-01013-P, Application 070314-4, indicates that the water quality treatment provided in
the widened swales is to compensate future improvements to the Turnpike mainline. See
Appendix F for excerpts from permit 13-01013-P.
4.7.2 Ultimate Build Alternative
Proposed roadway improvements within Drainage System C9_TPK, under the Ultimate Build
Alternative, focus on widening the Turnpike connector to I-95 southbound. The Ultimate
Build Alternative will add 0.9 Acres of impervious area to the drainage system. This will
require 0.09 Ac-ft of dry-retention to meet water quality. The treatment volume
requirement for this system can be met by providing compensating treatment in Drainage
System C9_GGI, which has surplus capacity in its dry retention pond.
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report 26
Figure 4-7 Drainage System C9_TPK
4.7.3 Interim Build Alternatives
In this drainage system, roadway improvements proposed for Interim Build Alternatives 3A,
3B, 3C, and 4 are the same as the improvements proposed for the Ultimate Build
Alternative. As such, the potential stormwater treatment methods described for the
Ultimate Build Alternative are applicable for the interim build alternatives.
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report 27
4.8 System C8_NW17th
This drainage system was delineated due to potential considerations in closing the NW 12th
Avenue on-ramp to SR 826. To maintain connectivity to SR 826, NW 17th Avenue would be
widened at the intersections to provide additional turn lanes and a new bridge at NW 165th
Street crossing the NW 17th Avenue Canal would be provided.
4.8.1 Existing Condition
System C8_NW17th covers the area of NW 17th Avenue from NW 163rd Street to the
SR 826. It is slightly less than half a mile long and within the 1-mile buffer of the Anodyne
contamination plume. NW 17th Avenue is a County owned two lane undivided rural road
with no dedicated drainage system. There are, however, a few drainage inlets mostly along
the western swale area, as shown in Figure 4-8, but there is no formal conveyance system
to get runoff to the inlets. Construction plans for NW 17th Avenue were unavailable from
Miami-Dade County at the time of this study. The assumption is made that each of the
sparsely placed drainage inlets is connected to an exfiltration trench of undetermined length
and condition. The roadway is crowned such that runoff from the southbound lane
sheet-flows into a flat swale area shared with a residential neighborhood while runoff from
the northbound lane sheet-flows into a 15-ft wide flat strip of sod before overflowing into
the NW 17th Avenue canal. In general, runoff generated within this system overtops NW
17th Avenue and flows into the NW 17th Avenue canal, which discharges into the C-8 Canal.
4.8.2 Ultimate Build Alternative
In the Ultimate Build Alternative, the NW 12th Avenue on-ramp to SR 826 will remain open,
thus not requiring alternative connectivity to SR 826. There are no roadway improvements
proposed within Drainage System C8_NW17th under the Ultimate Build Alternative.
4.8.3 Interim Build Alternatives
Roadway improvements proposed within this drainage system, under Interim Build
Alternatives 3A, 3B, and 3C will add 1.2 Acres and 0.13 Ac-ft of dry-retention will be needed
to meet water quality requirements. There are no roadway improvements proposed within
Drainage System C8_NW17th under Interim Build Alternative 4.
Options to meet water quality needs within this system are limited by the NW 17th Avenue
Canal on the east side and residential development along the west side. The geometric
constraints of the system area leave little room for stormwater treatment outside of the
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report 28
roadway R/W. Furthermore, the use of exfiltration trench in this system is discouraged by
FDEP because it is within the 1-mile buffer of the Anodyne contamination plume. The
approach to meeting water quality is to provide as much treatment within the existing R/W
and provide compensating treatment in adjacent system to balance any shortcomings in this
drainage system.
A review of the potential roadway typical section for this system indicates a shallow ditch
that can be utilized as a dry-retention swale for the southbound lane. The ditch is divided
into two separate swales by NW 166th Street. Each swale would need an outfall into the NW
17th Avenue Canal and it would be beneficial to have an equalizer pipe connecting the
swales under NW 163rd Street. The ditches would have side slopes of 1H:3V, average width
of 5.5-ft, a combined length of 1,100-ft and a retention depth of 0.5-ft to provide 0.07 Ac-ft
of dry-retention treatment. The remaining 0.06 Ac-ft of dry-retention treatment would need
to be provided in an adjacent drainage system with surplus capacity. Coordination with
Miami-Dade Department of Regulatory and Economic Resources (RER) will be needed to
obtain a permit for construction of an outfall into the NW 17th Avenue Canal.
Figure 4-8 Drainage System C8_NW17th
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report 29
4.9 Drainage Analysis Summary
Preliminary water quality and attenuation calculations performed for the study are located in
Appendix B. They are also summarized in Table 4-1 and Table 4-2, shown below. The
treatment/storage quantity provided for each receiving water body exceeds the required
amount for each Build Alternative.
Table 4—1: Drainage System Characteristics
Drainage
System
Build Alternatives
Existing Ultimate Interim
3A Interim
3B Interim
3C Interim
4
TA EI EP PI PP PI PP PI PP PI PP PI PP
C8_I95-S 39.4 30.7 8.7 2.0 6.7 0.4 8.3 2.0 6.7 2.0 6.7 0.4 8.3
C8_PR 36.3 18.7 17.6 2.3 15.3 1.9 15.7 2.2 15.5 2.2 15.5 1.9 15.7
C8_GGI 118.8 64.8 54.0 6.0 48.0 0.4 53.6 1.1 52.9 3.6 50.4 1.0 53.0
C8_I95-N 18.6 13.7 4.9 2.2 2.7 0.0 4.9 0.0 4.9 0.0 4.9 0.0 4.9
C8_NW17 4.0 2.0 2.0 0.0 2.0 1.2 0.8 1.2 0.8 1.2 0.8 0.0 2.0
C9_GGI 72.4 40.8 31.6 7.3 24.3 3.3 28.3 3.6 28.0 3.8 27.8 3.5 28.1
C9_TPK 19.9 11.1 8.9 0.9 8.0 0.9 8.0 0.9 8.0 0.9 8.0 0.9 8.0
NOTES:
1. TA = Total Area in drainage system (Ac).
2. EI = Existing Impervious Area (Ac).
3. EP = Existing Pervious area (Ac).
4. PI = Proposed Increase in impervious area (Ac).
5. PP = Proposed Pervious area (Ac).
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report 30
Table 4—2: Preliminary Calculation Summary
Drainage
System
Build Alternatives
Ultimate Interim 3A Interim 3B Interim 3C Interim 4
WQ ATT PRV WQ ATT PRV WQ ATT PRV WQ ATT PRV WQ ATT PRV
C8_I95-S 0.21 0.20 1.20 0.04 0.04 0.30 0.21 0.20 1.20 0.21 0.20 1.20 0.04 0.04 0.30
C8_PR 0.24 0.23 1.60 0.20 0.20 1.60 0.22 0.23 1.60 0.22 0.23 1.60 0.24 0.23 1.60
C8_GGI 0.63 0.63 0.72 0.04 0.00 0.00 0.12 0.13 0.72 0.38 0.38 0.72 0.10 0.13 0.72
C8_I95-N 0.41 0.22 0.41 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 C8 NW17 0.00 0.00 0.00 0.13 0.11 0.07 0.13 0.11 0.07 0.13 0.11 0.07 0.00 0.00 0.00
C9_GGI 0.78 0.69 1.80 0.34 0.31 1.80 0.38 0.31 1.80 0.39 0.31 1.80 0.36 0.31 1.80
C9_TPK 0.09 0.08 0.00 0.09 0.08 0.00 0.09 0.08 0.00 0.09 0.08 0.00 0.09 0.08 0.00
Receiving Water
Body
Build Alternatives
Ultimate Interim 3A Interim 3B Interim 3C Interim 4
WQ ATT PRV WQ ATT PRV WQ ATT PRV WQ ATT PRV WQ ATT PRV C-8 Canal 1.48 1.28 3.93 0.41 0.35 1.97 0.67 0.67 3.59 0.94 0.92 3.59 0.34 0.37 2.62 C-9 Canal 0.88 0.77 1.80 0.43 0.39 1.80 0.47 0.39 1.80 0.49 0.39 1.80 0.45 0.39 1.80
NOTES:
1. WQ = Required treatment volume to meet water quality requirements (Ac-ft).
2. ATT = Required storage volume to attenuate peak discharge (Ac-ft).
3. PRV = Treatment/storage volume provided by proposed design (Ac-ft).
4. Treatment/storage quantity provided for each receiving water body exceeds the required amount.
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report 31
5. FLOODPLAIN
According to the Flood Insurance Rate Maps published by the Federal Emergency
Management Agency (FEMA), a portion of the study area is within Special Flood Hazard
Zone AE while the remainder of the study area is outside of the floodplain. See Figure 5-1
below. The 1% annual chance flood (100-year or Base Flood) in Zone AE is estimated to
range from Elevation 6.0-ft to 7.0-ft NGVD. Areas identified within Zone X or Zone X-500
are estimated to have less than one foot or no flooding at all during the Base Flood.
Roadway improvements proposed by this project are estimated to be no lower than
elevation 9.0 NGVD, based on elevations extrapolated from limited As-built plans. As such,
the facility is anticipated to be open to traffic during the Base Flood. There are no regulated
floodways within the project limits. See Appendix A, for the Location Hydraulics
Memorandum.
Figure 5-1 FEMA Floodplain Map
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report 32
6. CROSS DRAINS
There are no major cross drains in this project.
7. WATERBODY CROSSINGS
Roadway improvements proposed by this study will involve work within the C-8 Canal and
the NW 17th Avenue Canal. The C-8 Canal is under the jurisdiction of South Florida Water
Management District (SFWMD) and the Army Corp of Engineers and the NW 17th Avenue
Canal is under the jurisdiction of Miami-Dade Department of Regulatory and Economic
Resources (RER).
7.1 I-95 over C-8 Canal (Bridge No. 870348)
Existing Bridge 870348, shown below in Figure 7-1, carries I-95 northbound and
southbound traffic over the C-8 Canal. Interim Build Alternative 3A widens the bridge while
Interim Build Alternatives 3B, 3C and the Ultimate Build provide a new bridge for
southbound traffic. In Build Alternative 3A, improvements to the Bridge will widen the
footprint towards the west and require piles in the C-8 Canal. Preliminary calculations
indicate that the existing bridge low member elevation of 7.66 ft-NGVD 29 (6.10 ft-NAVD
88) can be maintained for the widening in Build Alternative 3A as it meets the 2.0-ft
minimum vertical clearance over the Normal High Water of the Canal. For the partial bridge
replacements for Build Alternatives 3B, 3C and the Ultimate Build, the bridge will need to be
raised to meet minimum vertical clearance requirements, as the anticipated widening for
these alternatives would reduce the vertical clearance below acceptable limits if maintained
at the existing elevation. The portion of the existing bridge carrying northbound traffic will
remain for the aforementioned alternatives. New piles placed in the C-8 Canal will be
aligned with existing piles to minimize hydraulic impacts (head loss) in the Canal. For more
information on improvements to this bridge, see the Bridge Analysis Report-Interim Build
Alternatives and the Bridge Analysis Report-Ultimate Build Alternative prepared as part of
the PD&E Study.
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report 33
Figure 7-1 Bridge No. 870348 (I-95 over C-8 Canal)
7.2 NW 167th Street over NW 17th Avenue Canal (Culvert Extension)
Potential considerations in closing the NW 12th Avenue on-ramp to SR 826 will require
improvements to the NW 17th Avenue interchange with SR 826 that will widen it towards the
north and south. This will require extending the existing culvert in the NW 17th Avenue
Canal by approximately 15-ft on the northern end and 10-ft on the southern end to
accommodate the widened footprint of NW 167th Street. See Figure 7-2 below. Existing
plans show that the culvert at this location was built in the early 60’s and consists of 10-in
reinforced concrete walls with inside dimensions of 10-ft by 10-ft. In general, RER agreed
to allow culvert extension at this location. The culvert extension proposed for this location
will have dimensions of 10-ft by 10-ft to match the existing culvert. See Appendix C for
notes of the meeting held on 10/15/2012.
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report 34
Figure 7-2 Culvert Extension (NW 167th ST Over NW 17th Ave. Canal)
7.3 NW 165th Street over NW 17th Avenue Canal (Proposed Culvert)
A new roadway connection from NW 165th Street to NW 17th Avenue, across the NW 17th
Avenue Canal, is proposed by this study to provide alternate connectivity and mitigate the
potential removal of the NW 12th Avenue on-ramp to SR 826. The Bridge Analysis Report,
prepared as a part of this PD&E study, recommends a culvert for the NW 17th Avenue Canal
crossing and approximately 500 linear feet of bulkhead along the western bank of the canal.
The Study Team met with RER on October 15th 2012 to confirm that a culvert crossing
would be acceptable at this location. In general, RER agreed to allow a culvert at this
location as long as certain requirements are met such as providing a maintenance access
pad on either side of the culvert and hydraulic modeling as needed. See Appendix C for
meeting notes.
N CULVERT EXTENSION NW 17TH AVENUE
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report 35
Existing plans show that the culvert (SR 826 crossing), just north from NW 165th Street,
was built in the early 60’s and consists of 10-in reinforced concrete walls with inside
dimensions of 10-ft by 10-ft. For the purposes of estimating a project cost, two Alternatives
based on the existing upstream culvert were considered for the proposed culvert.
Alternative 1 provides a single 10-ft x 10-ft culvert while Alternative 2 provides two
10-ft x 10-ft culverts, as shown in Figure 7-3 below. If this crossing is needed, the actual
dimensions of the proposed culvert will be determined during the design phase of this
project when the Bridge Hydraulics Report is prepared for this crossing.
Figure 7-3 Proposed Culvert (NW 165th ST Over NW 17th Ave. Canal)
8. PERMITTING
8.1 Existing Permits
The South Florida Water Management District (SFWMD) and Miami-Dade Department of
Regulatory and Economic Resources (RER) were contacted to obtain existing permits within
the study area. Relevant permits are summarized below. See Appendix F for excerpts
from these permits.
SFWMD Permit 6P79-103, Application X000006257
Issued 1979.
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report 36
Connector ramp provided from Turnpike to SR 826 West. Designers felt extra pavement width would not “contribute greatly to existing conditions or contribute to the degradation of water quantity.” Receiving waterbody is C-9 Canal.
SFWMD Permit 85-00070-S, Application X000013200
Issued 1985
No documentation available.
SFWMD Permit 85-00070-S, Application 090225-2
Issued 2009.
Modification of surface water management system to serve an additional 6.8 acres of impervious area for the I-95 Managed Lanes. Project site is a section of I-95 from north of Golden Glades Interchange to the Miami-Dade/Broward County boundary line.
SFWMD Permit 85-00070-S, Application 120327-2
Issued 2012.
Modification of surface water management system to serve an additional 10.62 acres of impervious area for the I-95 Express Lanes. Project site is a section of I-95 from north of Golden Glades Interchange to the Miami-Dade/Broward County boundary line. Receiving waterbody is C-9 Canal.
SFWMD Permit 13-01013-P, Application 110713-6
Issued 2011.
Modification of surface water management system to serve Turnpike Golden Glades Toll Plaza area. Proposed improvements include conversion of toll plaza to All Electronic Tolling (AET). This resulted in a reduction of existing impervious area by 3.57 acres. Existing storage was not impacted and additional storage is was provided for future use by the Turnpike.
RER Permit OF 401
Issued 1991
Improvements of the existing drainage system serving I-95 from NW 151st Street to approximately one mile south of SR 860. Work done as part of SPN 87270-3419
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report 37
8.2 Proposed Permits
The Study Team has coordinated with SFWMD and RER to identify permits related to the
stormwater management system for this project. See Appendix C for documentation
related to those meetings. The following drainage related permits will be required for this
project.
Stormwater Management System
SFWMD has stated that they will make the final determination of whether a permit modification or new permit will be required when the project proceeds to the permitting phase. The reason for this is because there are portions of the interchange that have been permitted incidental to roadway work but there is no cohesive permit for the interchange itself.
RER has indicated that they will not require a permit for the stormwater management systems that serves FDOT roadways since they are being permitted through SFWMD. However, if work along NW 17th Avenue is required due to the closing of the NW 12th Avenue on-ramp to SR 826, then RER will require a Class II permit since the roadway is County owned and it has existing outfalls into the NW 17th Canal.
Right of Way (R/W) Occupancy
A R/W occupancy permit, from SFWMD, will be needed for proposed improvements to the I-95 Bridge over the C-8 Canal.
If the NW 12th Avenue on-ramp to SR 826 is closed and work is done in the NW 17th Avenue Canal, a Class III permit, from RER, will be needed for the work. The permit would include bulkheading, the culvert extension at NW 167 Street and a proposed culvert at NW 165th Street.
9. CONCLUSIONS
Based on preliminary calculations, the stormwater management systems proposed by this
study meet existing water quality standards as set forth in Chapter 62-302 of the Florida
Administrative Code. In addition, the treatment/storage quantity provided for each
receiving water body exceeds the required amount for each Build Alternative. The approach
to meeting water quality requirements is to provide treatment for the increase in impervious
area and restore or replace existing permitted treatment facilities impacted by this project.
Following this approach, Right-of-Way acquisition is not needed to meet current permitting
Golden Glades Interchange PD&E Study
From SR 826/Palmetto Expressway Eastbound to I-95 Northbound
Golden Glades Interchange – Stormwater Management Report 38
requirements. However, any Right-of-Way acquired as part of the roadway improvements
may prove to be advantageous in providing water treatment.
10. REFERENCES
1. FDOT 2013 Drainage Manual
2. FDOT 2012 Storm Drains Handbook
3. FDOT 2012 Plans Preparation Manual
4. FDOT 2013 Design Standards
5. FDOT 2008 District 6 Exfiltration Trench Reference Manual
6. FDOT 2004 Stormwater Management Facility Handbook
7. SFWMD 2012 Permit Information Volume IV
8. SFWMD 1999 Permit Information Manual Volume V
9. SFWMD 2002 Best Management Practices for South Florida Urban
Stormwater Management Systems