synoptophore mt-364 - medical partner › sites › default › files › mt-364_e3-4.pdf ·...

2
Synoptophore MT-364 Aiming at new levels in quality

Upload: others

Post on 27-Jun-2020

4 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Synoptophore MT-364 - Medical Partner › sites › default › files › mt-364_e3-4.pdf · Synoptophore MT-364 A i m i n g a t n e w l e v e l s i n q u a l i t y. Outstanding durability

Synoptophore

MT-364A i m i n g a t n e w l e v e l s i n q u a l i t y

Page 2: Synoptophore MT-364 - Medical Partner › sites › default › files › mt-364_e3-4.pdf · Synoptophore MT-364 A i m i n g a t n e w l e v e l s i n q u a l i t y. Outstanding durability

Outstanding durability and substantial functionsThe l ist below wil l show you what a wide range of examination and correction work this new synoptophore is equipped for. All devices are arranged for easy handling and a new wide Haidinger’s brushes’ device rotation range and wider automatic flashing count range are provided. Performance is further enhanced with the stepless diaphragm for fi eld adjustment and in combination with other devices such as the half mirror head, etc.

The Snoptophore that you are looking for…

MT-364

S p e c i f i c a t i o n s

D i m e n s i o n s

310530

390

Simultaneous perception, fusion, stereopsis, vergence, ret inal correspondence, monocular position, single eye fixation examination, removal of suppression, strengthened fusion, eyeball exercise and correction of retina.

V:Vertical H:Horizontal S:Square

Examination, Exercise and Correction Capability

330-2 IWAFUNE, NAKANO-SHI, NAGANO-KEN, 383-8585, JAPANTEL.+81-269-22-4512 FAX.+81-269-26-6321URL:http://www.takagi-j.com E-mail:[email protected]

● Design and specifi cations are subject to change as improvements are made to the product.

CB97001 Rev.3 Printed in Japan 2009.4 KY

Slides Complete 13 Sets

Simultaneous perception Red Bind 3 Sets

R1  Car  5.5°V 8.5°H R2  Garage 11°V13°H

R3  Butterfl y  4°V 6°H R4  Net     7°φ

R5  X  1°S R6  Square   1°S

Fusion White Bind 4 Sets

W1.2 Rabbit  11°S

W3.4 Elephant  6°S

W5.6 Bear   7°S

W7.8 Bubble Car  4°V 8°H

Stereopsis Yellow Bind 3 Sets

Y1.2 Wicket, Ball 10°V 3°H

Y3.4 Seal, Balanced Balls 6°V 5°H

Y5.6 Airplane and Four Parachutes 17°V 15°H

Maddox Green Bind 2 Sets

G1 Red Circle 3.5°φ G2 Green Square 6.5°S

G3 γ Angle G4 Arrow

Special Blue Bind 1 Set

B1 After Image (Vertical Lines)

B2 After Image (Horizontal Lines)

Pupil Adjusting Distance 45~ 80mm

Chinrest Height(from eyepiece tube) 60~ 130mm

Slides 13 sets

Automatic Flashing Device 10-400 times per minute

Manual Flashing Device Push button operation

Stepless Diaphragm Visual fi eld (angle) adjustment

Haidinger’s brushes’ device 50-100 revolution per minute

Target Illuminating Lamp 6V 0.5A, one each for left and right

After Image Lamp 12V 2A, one each for left and right

Power AC100,120,230V, 50/60Hz

Power Consumption 90VA

Fuse 1A

Weight 20kg

Half Mirror Heads 1 set