t31 - what's new in visualization

42
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Rev 5058-CO900F PUBLIC INFORMATION T31 - What's New in Visualization

Upload: buihanh

Post on 09-Dec-2016

225 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.Rev 5058-CO900F

PUBLIC INFORMATION

T31 - What's New in Visualization

Page 2: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.PUBLIC INFORMATION 2

What’s New in Visualization Contents

Software

Hardware

- PanelView Plus 7 Standard

- Industrial Computers

- FactoryTalk View SE (Site Edition)

- FactoryTalk View ME (Machine Edition)

- MobileView

Page 3: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.Rev 5058-CO900F

PUBLIC INFORMATION

PanelView Plus 7 Standard

Page 4: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.PUBLIC INFORMATION

PanelView Portfolio

PanelView ClassicPanelView Standard

PanelView Enhanced

PanelView Plus

PanelView Plus

Compact

PanelView Plus 6

…PanelView

Plus 7

Since 1989

PanelView Plus 7 extends the portfolio

Page 5: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.PUBLIC INFORMATION

PanelView Plus 7 Standard

5

Decrease time to market…

Increased screen resolution…

Standard Model – Single Ethernet

Machine Builder Focus

Sizes: 4”-15”

Single Ethernet

Touch Screen

Low Profile, Composite Bezel

FactoryTalk View Machine Edition - supporting

MER files back to 3.2

5 Catalogs – Allen-Bradley Branded

5 Catalogs – No BrandingWidescreens …..

New Display Sizes…..

ATEX Certifications …..

Page 6: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.PUBLIC INFORMATION

PanelView Plus 7 StandardFeatures & Benefits

Standard

4.3”W, 5.7”, 6.5”, 9”W, 10.4”, 12”W, 15”

Low profile composite bezel

Resistive touch screen

Single port Ethernet

ARM processor

512 MB Flash Memory / 512 MB RAM

Windows CE 6.0 standard features

DC powered

Removable Battery

Targeted for simpler / smaller applications

ATEX Certification, Class 1 Div. 2

Machine Builder Focused

• OEM Optimized Design

• Expanded Processing Power

• Composite bezel

• Competitive Solution• More screen options

• Greater resolution

• Wide screen options

• Application Size Limits

• 1 Controller

• ≤25 Screens

• ≤200 Alarms

Page 7: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.PUBLIC INFORMATION

PanelView Plus 7 PerformanceFeatures & Benefits

7

Performance

6.5”, 9”W, 10.4”, 12”W, 15”, 19”

Low profile painted aluminum bezel

Resistive touch screen with keypad options

Ethernet with embedded switch (DLR)

X86 processor

1 GB Flash Memory / 512 MB RAM

Windows CE 6.0 extended features

DC and AC power options

Targeted at larger / complex applications

Marine Certification (Future release)

ATEX Certification (Future release)

Complex Applications

Robust Design

Expanded Processing Power

Complex ApplicationsExamples: ≤300 Screens

≤3,000 Tags

≤400 Alarms

Ideal for Variety of IndustriesExamples:

Process

Metals

Mining / Aggregate

Marine

Tire and Rubber

Page 8: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.PUBLIC INFORMATION

PanelView Plus 7 Features

8

Product FeaturesPanelView Plus 7

Standard model

PanelView Plus 7

Performance model

FactoryTalk Machine Edition Y Y

ViewPoint Y Y

Memory RAM / Flash 512 MB / 512 MB 512MB / 1 GB

PDF Viewer Y Y

Active X Controls

(Email, DataStorePlus, Recipe) Y Y

Remote Terminal Control

(Based on VNC) Y Y

FTP Server Y Y

MPEG Video playback N Y

Microsoft Office Viewers N Y

Microsoft Internet Explorer N Y

Remote Desktop Services N Y

Ethernet Connectivity Y (Single Only) Y (DLR Only)

CPU ARM 1Ghz x86 1.6Ghz

Screen Sizes 4.3”-15” 7”-19”

Application Sizes1 Controller, 25 Screens,

200 AlarmsLarger Applications

Catalog numbers 2711P-xxxxx8S 2711P-xxxxx9P

Page 9: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.PUBLIC INFORMATION

PanelView Plus 7Ethernet Connectivity

PanelView Plus 7 Performance

line comes with an embedded

switch (DLR).

PanelView Plus 7 Standard

version include an embedded

Ethernet Port.

Page 10: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.PUBLIC INFORMATION

PanelView Plus 7 Features

10

Screen resolutions for PanelView Plus 7

Standard and Performance are the same.

Communication options:

Ethernet Only

Standard 4”-15” Single Port

Performance 7”-19” DLR

Size Resolution X Y

4” Wide WQVGA 480 272

6” VGA 640 480

7” VGA 640 480

9” Wide WQVGA 800 480

10 SVGA 800 600

12” Wide WXGA 1280 800

15” XGA 1024 768

19” SXGA 1280 1024

Page 11: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.PUBLIC INFORMATION

PanelView Plus 7 SD Card Data Storage

Quick and Easy Terminal Copy & Restore

Use an SD card to quickly create copies of a terminal to reduce your time to market or restore a terminal.

• Operating system

• Network configuration and terminal settings

• FactoryTalk® View Machine Edition (ME) runtime file

• Datalogs and Recipe files

Page 12: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.PUBLIC INFORMATION

PanelView Plus 7 Standard Anatomy

12

Mobile ready with VNC support and FactoryTalk Viewpoint

With the embedded PDF Viewer, show: • User Manuals • Installation Manuals • SOPs (Standard Operating Procedures)

Faceplates and Add-on Instructions can save 50 – 90% of complex screen development time

ATEX and UL Class 1, Div 2 for demanding environments

Page 13: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.PUBLIC INFORMATION

PanelView Plus 7 Standard Anatomy

13

SD storage card slot for data storage and terminal replication

USB Ports for quick upload and download to the terminal

New installation clamps provide fast and simple terminal installation and removal

Embedded Ethernet port for connectivity from the machine to the enterprise

Page 14: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.PUBLIC INFORMATION

PanelView Plus 6 Compact vs PanelView Plus 7 Standard display sizes

4.3 in. wide(480x272)

5.7 in.(640x480)

6.5 in.(640x480)

9.0 in. wide(800x480)

12.1 in. wide(1280x800)

10.4 in.(800x600)

15.0 in.(1024x768)

3.5 in.(320x240)

5.7 in.(320x240)

10.4 in.(640x480)

More Screens Sizes and Greater Resolution

Page 15: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.PUBLIC INFORMATION

PanelView Plus 7 Release Schedule and Features

Page 16: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.PUBLIC INFORMATION

PanelView Plus 7 Release Schedule

Release 1 – Q1 / 2015

Standard Models

• 4”-10”

• Single Ethernet

• Associated Accessories

Release 2 – Q3 / 2015

Additional Standard Models

• 12” and 15” single Ethernet

Performance Models• 7” – 19” all DLR

• Associated accessories

Adapter Plates

Page 17: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.Rev 5058-CO900F

PUBLIC INFORMATION

MobileView

Tethered Version

August 2014

Page 18: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.PUBLIC INFORMATION 18

MobileViewBenefits

Increase operator productivity

through ergonomic designed

mobile HMI

Contributing to a safe production

environment

Reduced development costs by

reusing standardized FactoryTalk

View ME applications

Page 19: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.PUBLIC INFORMATION

MobileViewAnatomy

19

3 position

enabling switch

Ruggedized housing

1m drop rated, IP65, 0-45 degC

Software

assignable

function keys

Hardwired E-stop

10” wide screen

(1280x800)

Optional pushbutton

or Key switch

2Gb application storage

4Gb RAM, Intel Atom CPU

FactoryTalk

View ME

Runtime

5m, 10m, 15m cable

with “quick connect”

connector

Page 20: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.PUBLIC INFORMATION 20

MobileViewApplications

HMI Applications with line of

sight requirements

Setup/calibration activities where

an operator needs to be in close

proximity to application with

access to HMI

Applications requiring local

safety functionality through E-

STOP or enabling switch

Maintenance applications

AFC

Q3 FY15

Page 21: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.PUBLIC INFORMATION

10” WXGA display (1280x800) with resistive touch

Intel Atom 1.46GHz CPU with 32GB SSD and 4GB RAM

1GB internal SD card for application storage

IP65, 0-45C operating temperature, 1M drop rated

5M, 10M or 15M cable and mounting bracket options

Hardwired E-STOP and 3-Position enabling switches

Optional software assignable function keys with either hardwired

momentary push button or key switch

FactoryTalk View Machine Edition 8.0

Windows Embedded Standard 7 operating system optimized for

FactoryTalk View ME Station

21

MobileViewTechnical specifications

Page 22: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.Rev 5058-CO900F

PUBLIC INFORMATION

6181 Integrated Display Computers

Series F Launch Overview

Page 23: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.PUBLIC INFORMATION 23

6181 Performance and Advanced Benefits

Enhanced performance for demanding applications with 4th Generation

Intel Core 64bit dual- and quad-core processors

Simplified installation with mounting assist clips

Efficient management with integrated backup/restore and diagnostic

capabilities

Increased reliability with gold plating on connectors and RAID support

Ease of installation drop in replacement Series E models

Decreased downtime with field replaceable components

Help reduce system costs with the latest Allen-Bradley Integrated Display Computers

Page 24: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.PUBLIC INFORMATION

6181 Performance and Advanced Applications

24

Meets tough industrial requirements to work in a variety of environments

Operating temperature range up to 55ºC (131ºF) on most models

Solid mechanical design withstands operating vibrations up to 2.0 g

Durable glass front on Advanced models for rugged industrial

environments

Stainless steel bezel options to meet food and beverage industry

equipment regulations

Global certifications and regulations include:

cULus listed, CE marked, RCM (C-Tick), WEEE, EAC, RoHS, KC

(Korean)

Page 25: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.PUBLIC INFORMATION

6181 Performance and AdvancedAnatomy

25

LED Indicators

Lockable USB

3.0 Port

Aluminum or

Stainless

Steel Bezel

User Interface

Button (UIB)

Installation

Assist Clip

Enhanced System Features

Programmable watchdog timer

Intel HD graphics 4600 for 2D/3D processing

PCI-Express expansion card support

Next generation UEFI Firmware

Touch input eliminates the need for a keyboard or

mouse

Operating system backup and restore

Diagnostic scanning

Critical component temperature monitoring and

history

Easy access to key information about battery status,

catalog number, and manufacturing date codes

Page 26: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.PUBLIC INFORMATION

6181 Integrated Display ComputersRelative Positioning

26

System Complexity/Functionality

Fle

xibi

lity

and

Pric

e

Core i3-4102E dual-core CPU

with 4GB RAM and single-touch

5x performance increase

Non-display and display models

with aluminum and stainless steel

bezels

Fanless design helps decrease

maintenance time

Core i7-4700EQ quad-core CPU

with 8GB RAM and multi-touch

14x performance increase

Powerful remote management

capabilities with Intel AMT 9.0

Technology

Non-display and display models

with aluminum bezels:

widescreen models (16:9) 15.6”

(396.3mm) and 18.5” ( 470 mm)

Performance Models

Advanced Models

Page 27: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.Rev 5058-CO900F

PUBLIC INFORMATION

6177R Updated Operating Systems

Page 28: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.PUBLIC INFORMATION

6177R Updated Operating Systems

28

Updated Service Packs

Windows 7 Pro (64 bit) SP1 to be applied in manufacturing in November/2014

Windows Server 2008 R2 SP1 to be applied in manufacturing in November/2014

Images posted to PCDC for download to allow updates in field

New Operating Systems

Windows 8.1 Industry Pro (6177R-MMAW8 & 6177R-RMAW8) AFC in November

2014

Windows Server 2012 R2 (6177R-MMS12 & 6177R-RMS12) AFC in November 2014

Page 29: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.Rev 5058-CO900F

PUBLIC INFORMATION

FactoryTalk® View v8.0CPR9 SR7High Level Review

Page 30: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.PUBLIC INFORMATION

FactoryTalk View Machine Edition 8.0

30

Configuration and Application Building

• Simplified project management

• Resizable alarm editor

• Application Manager workflow

Improved Run-Time Experience

• User Management controls

• Improved Domain Authentication

• Security Code changes

• Improved audit trail

• User Group Security functions

• Application loading Error-proofing

• Unsolicited Messages

Expanded Operating System Support

• Windows 8

• Windows 8.1 Update

• Windows 2012 Server R2

• Last release supporting older Microsoft Operating Systems & FactoryTalk View Machine Edition versions

Streamlined Installation

• Unattended Install

• Uninstall FactoryTalk View Tool

Support for PanelView Plus 7 Terminals

Page 31: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.PUBLIC INFORMATION

FactoryTalk View SE 8.0

31

Streamlined Installation

• Unattended Install

• Streamlined Client Install

• Uninstall FactoryTalk View Tool

• FT Historian Connectivity Tools

Improved Run-Time Experience

• Confirmation Popup*

• Button Enable Disable*

• Improved display of screen values

• Enhanced surface area for touch animation*

• New User Group Security functions

Alarming Improvements

• Alarm Severity Improvements

• Configure Alarm Sounds for Banner

• Out of Scope alarm occurrence handling

• Alarm Banner Sort Order improvements

• New edit filter button in Log Viewer

• New filter in Log Viewer

Configuration and Application Building

• Capture Value before Change

• Remote Studio

• Restoring existing FTAE application improvements

• VBA import and export

Expanded Operating System Support

• Windows 8

• Windows 8.1 Update

• Windows 2012 Server R2

• Cache Management Tool

• Last release supporting Older Microsoft Operating Systems

* - Supported in ViewPoint 8.0

Page 32: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.PUBLIC INFORMATION

Summary of Release

32

Products and Services Released:

FactoryTalk View Site Edition 8.0

FactoryTalk View Machine Edition 8.0

FactoryTalk ViewPoint 8.0

FactoryTalk Services Platform 2.70

FactoryTalk Alarms and Events 2.70

RSLinx Enterprise 5.70

RSLinx Classic 3.70

FactoryTalk Activation 3.62.01

Page 33: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.PUBLIC INFORMATION

Simplified Project Maintenance

33

• Improved handling of multiple FactoryTalk View Machine Edition applications on same PC

• Each project has its own private security configuration

• Users, Groups, and policy

Overview

• Allows user to restore a project (MER/APA) without overwriting any other project’s security configuration

• No need to be ‘careful’ when restoring MER or APA

Benefits

VME

Page 34: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.PUBLIC INFORMATION 34

Run-time User Management

VME

• New objects to manage native FactoryTalk and Windows-linked users

• Add, Delete, Change Group, Enable, Disable, Unlock, Change Account Properties, Change Password

• Add, remove, and modify user accounts while an MER is running

• Security configuration changes persisted in the MER

Overview

• No longer need to rebuild MER to change security configuration

• Support for 21 CFR Part 11 compliance

Benefits

Page 35: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.PUBLIC INFORMATION 35

Administrative Change Password

• Change Password button modified to add an Administrative mode, that allows user’s with access to change ANY user password

• Security configuration changes persisted in the MER

Overview

• Prevents users being ‘locked’ out of system by a malicious actor

• More administrative control of user account passwords

Benefits

VME

Page 36: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.PUBLIC INFORMATION

Windows 2008 and 2012 Server Active Directory Authentication Support

36

• Added LDAP and LDAP over SSL to the PanelView Plus terminals

• Existing application will work in Windows 2008/2012 domains, unchanged

• LDAP configuration applies to the terminal, not the application

• Operation transparent to Operator/User

Overview

• Windows-linked user and groups support centralized account management

• Support for 21 CFR Part 11 compliance

Benefits

VME

Page 37: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.PUBLIC INFORMATION

Changes to A-P Security Codes

37

Assume a user is a member of

more than one group. The groups

have the following configured

security codes

At run-time the user’s effective

security codes have changed in

v8.0 and later, compared to earlier

versions

Runtime Security Configuration A B C D

Group1 X X X

Group2 X X X

Effective A-P Security Codes A B C D

FactoryTalk View v8.0 X X

FactoryTalk View v7.0, and earlier X X X X

• All of a user’s A-P configurations are ANDed together in v8.0, and later

• If a user is a member of more than one A-P configuration, at run-time the user’s effective A-P Security Code permissions will be the most restricted set

• previous versions granted the most lenient effective Security Code A-P permissions

Overview

• Support for 21 CFR Part 11 compliance

Benefits

VME

Page 38: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.PUBLIC INFORMATION

Expanded Operating System Support

38

Windows 8, Windows 8.1 Update and Windows 2012 Server R2

join the list of supported operating systems in this release.

VME

VSE

Page 39: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.PUBLIC INFORMATION

Additional PanelView Plus Platform Support

39

PanelView Plus Platforms

PanelView Plus 6 Compact 1000

PanelView Plus 7 Standard

PanelView Plus 7 Performance

VME

Page 40: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.PUBLIC INFORMATION

Removing PanelView PlusPlatform Support

40

FactoryTalk View 8.0 is the LAST release to support v 3.2 and v4.0 MER

Using release after v8.0, it is not possible to create v3.2 or v4.0 MER

Using release after v8.0, it is not possible to execute v3.2 or v4.0 MER

Using release after v8.0, it IS possible to open and convert legacy

applications the newer project format

VME

Page 41: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.PUBLIC INFORMATION

Removing Operating System Support

41

FactoryTalk View v8.0 is the LAST release to support

Windows XP [any edition or SP]

Windows Vista [any edition or SP]

Windows 2003 Server [any edition or SP]

VME

VSE

Page 42: T31 - What's New in Visualization

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

www.rockwellautomation.com

Follow ROKAutomation on Facebook & Twitter.Connect with us on LinkedIn.

Rev 5058-CO900F

PUBLIC INFORMATION

Thank You