Retrofi tting kitsLow voltage breakers product support ABB SACE

Technical catalogue

1SDC001008D0201

07 Retrofitting_COP.indd 307 Retrofitting_COP.indd 3 28-06-2006 10:41:2328-06-2006 10:41:23

Page 2: Technical catalogue Retrofi tting kits - ABB Group · support ABB SACE Technical catalogue ... ABB SACE S.p.A. is a company in ABB group which has been operating in the ... The use

Index

1ABB SACE

General features ..........................................................................................................................4

Air circuit-breakers kit ..................................................................................................................8

Hybrid retrofi tting kit ..................................................................................................................12

Moulded-case retrofi tting kit ......................................................................................................14

Ordering codes ..........................................................................................................................18

Retrofi tting kits

07 Retrofitting_INT.indd 107 Retrofitting_INT.indd 1 28-06-2006 10:57:1528-06-2006 10:57:15

Page 3: Technical catalogue Retrofi tting kits - ABB Group · support ABB SACE Technical catalogue ... ABB SACE S.p.A. is a company in ABB group which has been operating in the ... The use

Who better than ABB knowsabout ABB products?

ABB SACE’s Technical AssistanceWe know how

ABB SACE S.p.A. is a company in ABB group which has been operating in the electrical apparatus sector since 1934. It has been part of the ABB group since 1988 and excels in designing and manufacturing of low voltage protection circuit-breakers.So far, our aim has always been the Customer satisfaction supporting him from the product selection till the after sale. Accordingly ABB SACE has created a highly qualifi ed

internal structure – ABB SACE’s Technical Assistance.ABB SACE’s Technical Assistance whose target is to grant you an all-round service for maintenance, adaptation and upgrading of your plants.In view of the demand for continuous improvement and optimization in managing assets and plants, ABB SACE’s Technical Assistance provides solutions which allow the useful life of low voltage circuit-breakers to be extended.

07 Retrofitting_INT.indd 207 Retrofitting_INT.indd 2 28-06-2006 10:57:2128-06-2006 10:57:21

Page 4: Technical catalogue Retrofi tting kits - ABB Group · support ABB SACE Technical catalogue ... ABB SACE S.p.A. is a company in ABB group which has been operating in the ... The use

ABB SACE’s Technical AssistanceAn all-round service

Beside the customer at all times

Maintenance operationsApart from maintenance of a faulty unit, which includes any type of emergency intervention, there is a complete preventive maintenance offer, ensuring those who manage the plant considerable advantages in terms of reliability, safety and reduction of costs.

Spare partsMaximum long-term guarantees: a stock of components which covers almost the entire range of apparatus products from the 70s to the present time. Furthermore, the capacity of designing and building local rapid intervention warehouses for the customers.

RepairsFunctional recovery of each electrical and mechanical part of the circuit-breaker with completely free estimates. Moreover, following a total overhaul of the circuit-breaker, the warranty is reinstated for 24 months from re-delivery.

Consultancy & Global AssistanceTechnicians competent regarding both the products and relevant Standards, are available to verify the situation of the installations and apparatus and to propose tailored maintenance plans, divided up into several levels of completeness.

Fault Prevention and ThermographyMethods for forecasting and preventing faults based on the use of advanced apparatus, which guarantees extremely reliable results. Among these is the thermographic check aimed at showing up any overheating of the conductive and insulating parts of the installation.

TrainingTraining programmes which give the personnel in charge of managing/maintaining the installation the know-how needed to achieve operating independence. Apart from technologies, a Technical Assistance truly “at the service” of customers: a team of capable and skilled people, always ready to listen to, understand and solve problems.

07 Retrofitting_INT.indd 307 Retrofitting_INT.indd 3 28-06-2006 10:57:2528-06-2006 10:57:25

Page 5: Technical catalogue Retrofi tting kits - ABB Group · support ABB SACE Technical catalogue ... ABB SACE S.p.A. is a company in ABB group which has been operating in the ... The use

4 ABB SACE

Retrofi tting kitsGeneral Features

Which circuit-breakers can be retrofi tted?

ISOL / FUSOL• Z63-Z100-Z250-Z630-Z800

• Z320–Z500 no longer available

• Fz160/100_Fz250/200_Fz630/400-500

• Manufactured from 1965

• Available only in shockproof version

• Arching chambers may contain asbestos

1965

OTOMAX• Breaking capacity class P1-P2-P3

• Versions: A-B-C

• Iu: 800A.....5000A

• Manufactured from 1961

• K release each phase

• Arching chambers may contain asbestos

1961

NOVOMAX G30• Breaking capacity till 42

• Iu: 800A -1250A - 1600 A

• Manufactured from 1970

• K release each phase

1970

07 Retrofitting_INT.indd 407 Retrofitting_INT.indd 4 28-06-2006 10:57:2828-06-2006 10:57:28

Page 6: Technical catalogue Retrofi tting kits - ABB Group · support ABB SACE Technical catalogue ... ABB SACE S.p.A. is a company in ABB group which has been operating in the ... The use

5ABB SACE

Retrofi tting kitsGeneral Features

Which circuit-breakers can be retrofi tted?

NOVOMAX G• Models : G2–G3–G4-G5-G6

• Ith from 1250A to 6300A

• Manufactured from 1980

• “T” electromechanical relay

• Electronic “S1-S2” relay

• L-S-I-G functions available

1980

MEGAMAX F• Models : F1-F2–F3-F4-F5-F6

• Type: B-N-S-H-V-L

• Iu: 1250A.....6300A

• Manufactured from 1990

• Electronic “AR1 / PR1” relais

• Dialog control units available

1990

MODUL• SH630 last version available

• Iu: 100A.....3200A

• Manufactured from 1975

1975

07 Retrofitting_INT.indd 507 Retrofitting_INT.indd 5 28-06-2006 10:57:2928-06-2006 10:57:29

Page 7: Technical catalogue Retrofi tting kits - ABB Group · support ABB SACE Technical catalogue ... ABB SACE S.p.A. is a company in ABB group which has been operating in the ... The use

6 ABB SACE

Renew your breaker, update your plant

Circuit-breakers that have been in service for many years no longer meet current reliability require-ments. Although these breakers still operate perfectly, they should be gradually replaced.Routine maintenance operations do not always completely satisfy your requirements. Problems relating to functionality, coordination and safety –such as the need to improve electri-cal and mechanical performances, to enlarge the installation or to adapt it to the standard - can, in fact, require retrofi tting operations, which are needed to replace inadequate or obsolete apparatus, or addition of new pieces of apparatus to the installation.

Retrofi tting kitsGeneral Features

ABB SACE offers the simplest solutions in order to migrate to new technology, avoiding extensive jobs on distribution panels that still meet construction, regulation and safety requirements.

ABB SACE has studied specifi c retrofi tting kits in order to replace its old circuit-breakers with direct or indirect solutions, using the latest circuit-breakers Emax, Iso-max and Tmax.

With minimal modifi cation and limited costs, retrofi tting kits are the best solution for upgrading your low voltage switchboards. The retrofi tting kit solutions improve the safety and the reliability of your plant, excluding the need

for expensive spare parts and lowering maintenance expenses. In addition, ABB SACE’s new Emax, Isomax and Tmax circuit-breaker bring together exceptional

07 Retrofitting_INT.indd 607 Retrofitting_INT.indd 6 28-06-2006 10:57:3128-06-2006 10:57:31

Page 8: Technical catalogue Retrofi tting kits - ABB Group · support ABB SACE Technical catalogue ... ABB SACE S.p.A. is a company in ABB group which has been operating in the ... The use

7ABB SACE

The ABB SACE retrofi tting kits cover the whole range of requirements you may have, from the single component to the large and complex installation.

The use of ABB SACE retrofi tting kits ensures you considerable advantages:• Reduced investments compared with those needed to install

completely new switchboards.

• Reduced assembly operation times and the possibility of spreading installation stoppages out over time, which increase the guarantee of service continuity.

• Maintenance and repairing costs saving.

• Save investments made on existing structures.

• Full matching with existing busbars systems.

• Prompt, easy and safety replacement.

• Light or no hardware modifi cations.

• Adaptation plugs for auxiliary applications.

• More control on the plant with new protection relays.

Retrofi tting kitsGeneral Features

ABB SACE has studied 3 different type of retrofi tting kits:

Air circuit-breakers kit

Hybrid retrofi tting kit

Moulded-case retrofi tting kit

mechanical reliability, the fl exibility of the latest series of solid-state releases and the most modern monitoring and communication features.ABB SACE responds to your problems with a complete service. In fact, the Technical Assistance works alongside the customer in a consultancy capacity and provides operative service. We are at your disposal to identify the obsolete apparatus for giving you the right solution.

07 Retrofitting_INT.indd 707 Retrofitting_INT.indd 7 28-06-2006 10:57:3528-06-2006 10:57:35

Page 9: Technical catalogue Retrofi tting kits - ABB Group · support ABB SACE Technical catalogue ... ABB SACE S.p.A. is a company in ABB group which has been operating in the ... The use

8 ABB SACE

Retrofi tting kitsAir circuit-breakers kit

Retrofi tting kit for air circuit-breakers

It is possible to replace the older types of air circuit-breakers as Otomax, Novomax, Megamax, with the latest Emax series by using the most conventional type of retrofi tting kit.This includes: custom-engineered migration connections, installation tools, safety shields and instructions manuals.The expertise required for the installation job is minimal and can be made out directly by the cus-tomer.

Sample of retrofi tting kit between OTOMAX P2C and EMAX E1

Special version of Retrofi tting KitOtomax P2C 3200 external neutral pole with Emax E4 four poles

Retrofi tting kit: what’s inside

ABB SACE retrofi tting kits are supplied complete with all the ac-

cessories and instructions for an easy and quick replacement of

the installed circuit-breakers:

• Silvered fi tting bars

• Insulators and crossbars support

• IP20 metal sheets

• Drilling templates for compartment door

• Mounting instructions

• Technical drawings

• New Emax electrical schemes

• Migration wiring diagrams

Full matching with existing busbars systems

07 Retrofitting_INT.indd 807 Retrofitting_INT.indd 8 28-06-2006 10:57:3628-06-2006 10:57:36

Page 10: Technical catalogue Retrofi tting kits - ABB Group · support ABB SACE Technical catalogue ... ABB SACE S.p.A. is a company in ABB group which has been operating in the ... The use

9ABB SACE

Retrofi tting kitsAir circuit-breakers kit

All the retrofi tting kits are supplied with instructions and wiring diagram

Megamax F1 or Novomax G2 EmaxABB SACE ha studied a special retrofi tting kit for Megamax F1 and Novomax G2. The kit grants the insertion of a complete Emax circuit-breaker in the Megamax or Novomax fi xed part with very light modi-fi cation of the switchgear.

In the picture : Emax E2N fi xed part modifi ed for insertion in Megamax F1S 2000 A fi xed part

Novomax G2-3-4 and Megamax F2-3-4 EmaxIt’s possible to replace the Novomax G2-3-4 and Mega-max F2-3-4 with the latest Emax series by using the most conventional type of retrofi tting kit. This includes: custom-engi-neered migration connections, installations tools, auxiliary connections and instructions manuals.

Megamax F2-retrofi tting kit Emax E2

07 Retrofitting_INT.indd 907 Retrofitting_INT.indd 9 28-06-2006 10:57:3928-06-2006 10:57:39

Page 11: Technical catalogue Retrofi tting kits - ABB Group · support ABB SACE Technical catalogue ... ABB SACE S.p.A. is a company in ABB group which has been operating in the ... The use

10 ABB SACE

Old circuit-breakers Air CBs retrofi tting kit code

OTOMAX

EMAX E1 EMAX E2

3 poles circuit-breakers

4 poles circuit-breakers

B N B N

800A 1250A 1600A 1250A 1600 1600A 2000A 1250A 1600A 2000AP1A 800A - P1B 800A 1SDA050748R1 1SDA050761R1 P1B 1000A - P1C 1250A 1SDA050748R1 1SDA050761R1 P1A/P2A 1250A 1SDA050750R1 1SDA050763R1P1B/P1C 1600A 1SDA050750R1 1SDA050763R1P2B/P2C 1600A 1SDA050750R1 1SDA050763R1 P1A 1600A 1SDA050751R1 1SDA050764R1P2A 1600A 1SDA050751R1 1SDA050764R1P1B 2000A 1SDA050751R1 1SDA050764R1P2B/P2C 2000A 1SDA050751R1 1SDA050764R1P1A/P2A/P3A 2000A 1SDA050753R1 1SDA050764R1P1B/P2B/P2C 2500A 1SDA050753R1 1SDA050766R1P3B/P3C 2500A 1SDA050753R1 1SDA050766R1P2A 800A - P2B/P2C 1000A - P2C 1250A 1SDA050749R1 1SDA050762R1P2A/P2B 3000A - P2C 3200A 1SDA050754R1P2A/P2B/P2C 4000A 1SDA050756R1P3A/P3B/P3C 4000A 1SDA050756R1P3A 1600A 1SDA050752R1 1SDA050765R1P3B/P3C 2000A 1SDA050752R1 1SDA050765R1P3A/P3B 3000A - P3C 3200A 1SDA050755R1

NOVOMAXG30 800A 1SDA050758R1 1SDA050760R1G30 1250A 1SDA050758R1 1SDA050760R1G30 1600A 1SDA050757R1 1SDA050759R1G2 1250A 1SDA063819R1 1SDA063821R1G2 1600A 1SDA063819R1 1SDA063821R1G2 2000A 1SDA063820R1 1SDA063822R1G2 2500A 1SDA063826R1 1SDA063833R1G3 2000A 1SDA063836R1 1SDA063838R1G3 2500A 1SDA063836R1 1SDA063838R1G3 3000A 1SDA063837R1 1SDA063839R1G4 3200A 1SDA063840R1 1SDA063841R1

MEGAMAXF1B 1250A 1SDA63802R1 1SDA63812R1F1N 1250A 1SDA63802R1 1SDA63812R1F1B 1600A 1SDA63802R1 1SDA63812R1F1N 1600A 1SDA63802R1 1SDA63812R1F1S 1250A 1SDA63807R1 1SDA63814R1F1S 1600A 1SDA63807R1 1SDA63814R1F1S 2000A 1SDA63809R1 1SDA63816R1F1B 2000A 1SDA63809R1 1SDA63816R1F1N 2000A 1SDA63809R1 1SDA63816R1F1H 1250A 1SDA63810R1 1SDA63817R1F1H 1600A 1SDA63810R1 1SDA63817R1F1L/V 1250A 1SDA63811R1 1SDA63818R1F1L/V 1600A 1SDA63811R1 1SDA63818R1F2H 2000A 1SDA63823R1 1SDA63827R1F2H 2500A 1SDA63824R1 1SDA63829R1F2L/V 2000A 1SDA63825R1 1SDA63832R1F2L/V 2500A 1SDA63825R1 1SDA63832R1F2S 2500A 1SDA63826R1 1SDA63833R1F2S 3000A 1SDA63826R1 1SDA63833R1F3S 2000A 1SDA63836R1 1SDA63838R1F3S 2500A 1SDA63836R1 1SDA63838R1F3S 3000A 1SDA63837R1 1SDA63839R1F4S 3200A 1SDA63840R1 1SDA63841R1

Solutions for installation of the new apparatus

Retrofi tting kitsAir circuit-breakers kit

07 Retrofitting_INT.indd 1007 Retrofitting_INT.indd 10 28-06-2006 10:57:4128-06-2006 10:57:41

Page 12: Technical catalogue Retrofi tting kits - ABB Group · support ABB SACE Technical catalogue ... ABB SACE S.p.A. is a company in ABB group which has been operating in the ... The use

11ABB SACE

New circuit-breakers version

EMAX E3 EMAX E4

S L N S H L S H

1250A 1600A 2000A 1250A 1600A 2500A 3000A 3200A 1600A 2000A 2500A 3200 2500A 2000 2500 4000A 3200A 4000A

Retrofi tting kitsAir circuit-breakers kit

07 Retrofitting_INT.indd 1107 Retrofitting_INT.indd 11 28-06-2006 10:57:4628-06-2006 10:57:46

Page 13: Technical catalogue Retrofi tting kits - ABB Group · support ABB SACE Technical catalogue ... ABB SACE S.p.A. is a company in ABB group which has been operating in the ... The use

12 ABB SACE

Hybrid retrofi tting kit for air circuit-breakers with moulded-case circuit-breakers

For those plants which require a minimum downtime for upgrades, ABB SACE has studied special retrofi tting kits for the replacement of the older types of air circuit-breakers 800-1250-1600 A as Otomax and Novomax G30, with up-to-date moulded-case circuit-breaker type Isomax S7.This type of solution allows putting the new apparatus directly in the fi xed part of Otomax or Novomax G30 circuit-breakers. The easy installation can be made out directly by the customer with a very fast replacement.

Retrofi tting kitsHybrid retrofi tting kit

A special MCCB Isomax S7 in the Novomax G30 fi xed part

The solution for your out of service problems Novomax G30 800-1250-1600 A Isomax S7S

07 Retrofitting_INT.indd 1207 Retrofitting_INT.indd 12 28-06-2006 10:57:4728-06-2006 10:57:47

Page 14: Technical catalogue Retrofi tting kits - ABB Group · support ABB SACE Technical catalogue ... ABB SACE S.p.A. is a company in ABB group which has been operating in the ... The use

13ABB SACE

Old circuit-breakers Hybrid retrofi tting kit code New circuit-breakers version

OTOMAX

Isomax S7

3 poles circuit-breakers

3 poles + neutralcircuit-breakers

S H

1250A 1600A 1250A 1600A

P1C/P2C 1250A 1SDA063769R1 1SDA063771R1

P1C/P2C 1600A 1SDA063770R1 1SDA063772R1

NOVOMAX3 poles

circuit-breakers4 poles

circuit-breakers

G30 800A - G30 1250A 1SDA063773R1 1SDA063774R1

G30 1600A 1SDA063775R1 1SDA063776R1

Solutions for installation of the new apparatus

Retrofi tting kitsHybrid retrofi tting kit

Otomax P2 1250-1600 A Isomax S7H

A special version with external pole

All the retrofi tting kits are supplied with instructions and wiring diagram

07 Retrofitting_INT.indd 1307 Retrofitting_INT.indd 13 28-06-2006 10:57:4828-06-2006 10:57:48

Page 15: Technical catalogue Retrofi tting kits - ABB Group · support ABB SACE Technical catalogue ... ABB SACE S.p.A. is a company in ABB group which has been operating in the ... The use

14 ABB SACE

Retrofi tting kitsMoulded-case retrofi tting kit

Retrofi tting kits designed for old series moulded-case breakers save on the investment necessary for electrical equipment and require a minimum downtime for their installation.Generally made by adaptation plates for the corresponding terminals, retrofi tting kits for moulded-case circuit-breakers are fi tted for prompt insertion into the old breaker’s fi xed part. Under request and against technical verifi cation, retrofi tting kits for moulded-case circuit-breakers may be fi tted with adaptation plugs for auxiliary applications so that only minimal mechanical work has to be done on the panel door.

ISOL/FUSOL/MODUL S1250-1600 Isomax S4-S6-S7

Old CB Isol/Fusolmoving part

Old CB Isol/Fusolfi xed part

Retrofi tting kit for newIsomax CB

New Isomax fi xed partplugged onto the oldIsol/Fusol one’s

MODUL S100-400 Tmax T1-T2-T3-T4-T5

Kits available:

Kits available:Isol Z320/500 Isomax S4-5Isol Z630/800 Isomax S6Fusol FZ 630 Isomax S6Modul S1250 Isomax S7Modul S1600 Isomax S7

Modul SN 100-125 Tmax T2N 160Modul SN 160-250 Tmax T4N 250

Modul SN 400 Tmax T5N 400Modul SH 100-125 Tmax T4H 250Modul SH 160-250 Tmax T4H 250

Modul SH 400 Tmax T5H 400

07 Retrofitting_INT.indd 1407 Retrofitting_INT.indd 14 28-06-2006 10:57:5228-06-2006 10:57:52

Page 16: Technical catalogue Retrofi tting kits - ABB Group · support ABB SACE Technical catalogue ... ABB SACE S.p.A. is a company in ABB group which has been operating in the ... The use

15ABB SACE

Retrofi tting kitsMoulded-case retrofi tting kit

Just rack out the old circuit-breaker and rack in the new one

Kit Modul S100/125 - Tmax T2 Kit Modul S160-250-Tmax T4

Kit Modul S400-Tmax T5 Tmax circuit-breakers installed on moulded fi xed parts

All the retrofi tting kits are supplied with instructions and wiring diagram

07 Retrofitting_INT.indd 1507 Retrofitting_INT.indd 15 28-06-2006 10:57:5428-06-2006 10:57:54

Page 17: Technical catalogue Retrofi tting kits - ABB Group · support ABB SACE Technical catalogue ... ABB SACE S.p.A. is a company in ABB group which has been operating in the ... The use

16 ABB SACE

Old circuit-breakers Moulded case retrofi tting kit code

ISOL

Isomax S4 Isomax S5

3 poles circuit-breakers

4 poles circuit-breakers

N N

250A 400A 400A 630A

Z320 250A UXAB129599101

Z320 320A UXAB129599101

Z500 500A UXAB129599101 UXAB129599102

Z320 400/500/630A UXAB129599101

Z800 800A UXAB129599101

FUSOL

FZ630 400/500/630A UXAB129599101

MODUL

SN100/125 PMP 100/125A 1SDA063777R1 1SDA063783R1

SN160/250 PMP 160/250A 1SDA063778R1 1SDA063784R1

SN400 PMP 400A 1SDA063779R1 1SDA063785R1

SN1250 WMP R1000/R1250 1250A UXAB129599101 UXAB129599102

SN1600 WMP R1600 1600A UXAB129599103 UXAB129599104

SH100/125 PMP 100/125A 1SDA063780R1 1SDA063786R1

SH160/250 PMP 160/250A 1SDA063781R1 1SDA063787R1

SH400 PMP 400A 1SDA063782R1 1SDA063788R1

SH1250 WMP R1000/R1250 1250A UXAB129599101 UXAB129599102

SH1600 WMP R1600 1600A UXAB129599103 UXAB129599104

Solutions for installation of the new apparatus

Retrofi tting kitsMoulded-case retrofi tting kit

07 Retrofitting_INT.indd 1607 Retrofitting_INT.indd 16 28-06-2006 10:58:0328-06-2006 10:58:03

Page 18: Technical catalogue Retrofi tting kits - ABB Group · support ABB SACE Technical catalogue ... ABB SACE S.p.A. is a company in ABB group which has been operating in the ... The use

17ABB SACE

New circuit-breakers version

Isomax S6 Isomax S7 Tmax T2 Tmax T4 Tmax T5

S L S L N N H N H

630A 800A 630A 1250A 1600A 1250A 1600A 160A 250A 250A 400A 400A

Retrofi tting kitsMoulded-case retrofi tting kit

07 Retrofitting_INT.indd 1707 Retrofitting_INT.indd 17 28-06-2006 10:58:0528-06-2006 10:58:05

Page 19: Technical catalogue Retrofi tting kits - ABB Group · support ABB SACE Technical catalogue ... ABB SACE S.p.A. is a company in ABB group which has been operating in the ... The use

18 ABB SACE

Retrofi tting kitsOrdering codes

Old circuit-breaker

Iu[A]

Icu[kA] New circuit-breaker Retrofi tting kit code

Otomax 3 poles

EMAX 3 poles Version

P1 800 A 800 32 E1B 800 FP HR + MP 1SD050748R1

P1 1250 A 1250 32 E2N 1250 FP HR + MP 1SD050750R1

P1 1600 A 1600 32 E2B 1600 FP HR + MP 1SD050751R1

P1 2000 A 2000 32 E3S 2000 FP HR + MP 1SD050753R1

P1B 1000 A 1000 32 E1B 1250 FP HR + MP 1SD050748R1

P1B 1600 A 1600 32 E2B 1600 FP HR + MP 1SD050750R1

P1B 2000 A 2000 35 E2B 2000 FP HR + MP 1SD050751R1

P1B 2500 A 2500 35 E3N 2500 FP HR + MP 1SD050753R1

P1C 1000 A 1000 36 E1B 1250 FP HR + MP 1SD050748R1

P1C 1250 A 1250 36 E1B 1250 FP HR + MP 1SD050748R1

P1C 1600 A 1600 36 E2B 1600 FP HR + MP 1SD050750R1

P1C 2000 A 2000 36 E2B 2000 FP HR + MP 1SD050751R1

P1C 2500 A 2500 36 E3N 2500 FP HR + MP 1SD050753R1

P2 800 A 800 52 E2N 1250 FP HR + MP 1SD050749R1

P2 1250 A 1250 52 E2N 1250 FP HR + MP 1SD050750R1

P2 1600 A 1600 55 E2N 1600 FP HR + MP 1SD050751R1

P2 2000 A 2000 55 E3S 2000 FP HR + MP 1SD050753R1

P2 3000 A 3000 57 E3N 3200 FP HR + MP 1SD050754R1

P2 4000 A 4000 57 E4S 4000 FP HR + MP 1SD050756R1

P2B 1000 A 1000 52 E2N 1250 FP HR + MP 1SD050749R1

P2B 1600 A 1600 52 E2N 1600 FP HR + MP 1SD050750R1

P2B 2000 A 2000 55 E2N 2000 FP HR + MP 1SD050751R1

P2B 2500 A 2500 55 E3N 2500 FP HR + MP 1SD050753R1

P2B 3000 A 3000 57 E3N 3200 FP HR + MP 1SD050754R1

P2B 4000 A 4000 57 E4S 4000 FP HR + MP 1SD050756R1

P2C 1000 A 1000 55 E2N 1250 FP HR + MP 1SD050749R1

P2C 1250 A 1250 55 E2N 1250 FP HR + MP 1SD050749R1

P2C 1600 A 1600 55 E2N 1600 FP HR + MP 1SD050750R1

P2C 2000 A 2000 55 E2N 2000 FP HR + MP 1SD050751R1

P2C 2500 A 2500 55 E3N 2500 FP HR + MP 1SD050753R1

P2C 3200 A 3200 57 E3N 3200 FP HR + MP 1SD050754R1

P2C 4000 A 4000 57 E4S 4000 FP HR + MP 1SD050756R1

P3 1600 A 1600 75 E3S 1600 FP HR + MP 1SD050752R1

P3 2000 A 2000 75 E3S 2000 FP HR + MP 1SD050753R1

P3 3000 A 3000 100 E4H 3200 FP HR + MP 1SD050755R1

P3 4000 A 4000 100 E4H 4000 FP HR + MP 1SD050756R1

P3B 2000 A 2000 75 E3S 2000 FP HR + MP 1SD050752R1

P3B 2500 A 2500 75 E3S 2500 FP HR + MP 1SD050753R1

P3B 3000 A 3000 100 E4H 3200 FP HR + MP 1SD050755R1

P3B 4000 A 4000 100 E4H 4000 FP HR + MP 1SD050756R1

P3C 2000 A 2000 75 E3S 2000 FP HR + MP 1SD050752R1

P3C 2500 A 2500 75 E3S 2500 FP HR + MP 1SD050753R1

P3C 3200 A 3200 100 E4H 3200 FP HR + MP 1SD050755R1

P3C 4000 A 4000 100 E4H 4000 FP HR + MP 1SD050756R1

Air circuit-breakers kit

NOTEKit available only complete with the new circuit-breaker. Air circuit-breaker retrofi tting kit has been studied for Otomax and Novomax G30 circuit-breaker in draw out version with rear horizontal terminals. Contact us if the installed circuit-breakers are in different version.

MAIN ACTIVITIES REQUIRED :• Put out of service the panel or the entire switchboard • Carry out the moving part of the Otomax / Novomax circuit-breaker• Remove the fi xed part of the Otomax / Novomax circuit-breaker• On a workbench fi t the branch connections to the fi xed part of the Emax circuit-breaker• Assembly the Emax fi xed part with retrofi tting kit in the switchboard compartment• Drillng templates of the compartment door

ALL THE RETROFITTING KITS HAVE BEEN STUDIED FOR REPLACEMENT OF OLD CIRCUIT- BREAKERS INSTALLED AS PER INDICATED IN THE INSTRUCTION MANUALS.

07 Retrofitting_INT.indd 1807 Retrofitting_INT.indd 18 28-06-2006 10:58:0528-06-2006 10:58:05

Page 20: Technical catalogue Retrofi tting kits - ABB Group · support ABB SACE Technical catalogue ... ABB SACE S.p.A. is a company in ABB group which has been operating in the ... The use

19ABB SACE

Retrofi tting kitsOrdering codes

Old circuit-breaker

Iu[A]

Icu[kA] New circuit-breaker Retrofi tting kit code

Otomax 4 poles

EMAX 4 poles Version

P1 800 A 800 32 E1B 800A FP HR + MP 1SDA050761R1

P1 1250 A 1250 32 E1B 1250A FP HR + MP 1SDA050763R1

P1 1600 A 1600 32 E2B 1600A FP HR + MP 1SDA050764R1

P1 2000 A 2000 32 E2B 2000A FP HR + MP 1SDA050766R1

P1B 1000 A 1000 32 E1B 1250A FP HR + MP 1SDA050761R1

P1B 1600 A 1600 32 E2B 1600A FP HR + MP 1SDA050763R1

P1B 2000 A 2000 35 E2B 2000A FP HR + MP 1SDA050764R1

P1B 2500 A 2500 35 E3N 2500A FP HR + MP 1SDA050766R1

P1C 1000 A 1000 36 E1B 1250A FP HR + MP 1SDA050761R1

P1C 1250 A 1250 36 E1B 1250A FP HR + MP 1SDA050761R1

P1C 1600 A 1600 36 E2B 1600A FP HR + MP 1SDA050763R1

P1C 2000 A 2000 36 E2B 2000A FP HR + MP 1SDA050764R1

P1C 2500 A 2500 36 E3N 2500A FP HR + MP 1SDA050766R1

P2 800 A 800 52 E2N 1250A FP HR + MP 1SDA050762R1

P2 1250 A 1250 52 E2N 1250A FP HR + MP 1SDA050763R1

P2 1600 A 1600 55 E2N 1600A FP HR + MP 1SDA050764R1

P2 2000 A 2000 55 E2N 2000A FP HR + MP 1SDA050766R1

P2B 1000 A 1000 52 E2N 1250A FP HR + MP 1SDA050762R1

P2B 1600 A 1600 52 E2N 1600A FP HR + MP 1SDA050763R1

P2B 2000 A 2000 55 E2N 2000A FP HR + MP 1SDA050764R1

P2B 2500 A 2500 55 E3N 2500A FP HR + MP 1SDA050766R1

P2C 1000 A 1000 55 E2N 1250A FP HR + MP 1SDA050762R1

P2C 1250 A 1250 55 E2N 1250A FP HR + MP 1SDA050762R1

P2C 1600 A 1600 55 E2N 1600A FP HR + MP 1SDA050763R1

P2C 2000 A 2000 55 E2N 2000A FP HR + MP 1SDA050764R1

P2C 2500 A 2500 55 E3N 2500A FP HR + MP 1SDA050766R1

P3 1600 A 1600 75 E3S 1600A FP HR + MP 1SDA050765R1

P3 2000 A 2000 75 E3S 2000A FP HR + MP 1SDA050766R1

P3B 2000 A 2000 75 E3S 2000A FP HR + MP 1SDA050765R1

P3B 2500 A 2500 75 E3S 2500A FP HR + MP 1SDA050766R1

P3C 2000 A 2000 75 E3S 2000A FP HR + MP 1SDA050765R1

P3C 2500 A 2500 75 E3S 2500A FP HR + MP 1SDA050766R1

Air circuit-breakers kit

NOTEKit available only complete with the new circuit-breaker. Air circuit-breaker retrofi tting kit has been studied for Otomax and Novomax G30 circuit-breaker in draw out version with rear horizontal terminals. Contact us if the installed circuit- breakers are in different version.

MAIN ACTIVITIES REQUIRED :• Put out of service the panel or the entire switchboard • Carry out the moving part of the Otomax / Novomax circuit-breaker• Remove the fi xed part of the Otomax / Novomax circuit-breaker• On a workbench fi t the branch connections to the fi xed part of the Emax circuit-breaker• Assembly the Emax fi xed part with retrofi tting kit in the switchboard compartment• Drillng templates of the compartment door

ALL THE RETROFITTING KITS HAVE BEEN STUDIED FOR REPLACEMENT OF OLD CIRCUIT- BREAKERS INSTALLED AS PER INDICATED IN THE INSTRUCTION MANUALS.

07 Retrofitting_INT.indd 1907 Retrofitting_INT.indd 19 28-06-2006 10:58:0728-06-2006 10:58:07

Page 21: Technical catalogue Retrofi tting kits - ABB Group · support ABB SACE Technical catalogue ... ABB SACE S.p.A. is a company in ABB group which has been operating in the ... The use

20 ABB SACE

Retrofi tting kitsOrdering codes

Old circuit-breaker

Iu[A]

Icu[kA] New circuit-breaker Retrofi tting kit code

Novomax 3 poles

EMAX 3 poles

Version

G30 1250A 1250 35 E1B 1250A FP HR + MP 1SDA05 0758R1

G30 1600A 1600 35 E2B 1600A FP HR + MP 1SDA050757R1

G30 800A 800 35 E1B 800A FP HR + MP 1SDA050758R1

G2 1250A 1250 50 E1N 1250A FP HR + MP 1SDA063819R1

G2 1600A 1600 50 E1N 1600A FP HR + MP 1SDA063819R1

G2 2000A 2000 50 E2N 2000A FP HR + MP 1SDA063820R1

G2 2500A 2500 45 E3N 2500A FP HR + MP 1SDA063826R1

G3 2000A 2000 75 E3S 2000A FP HR + MP 1SDA063836R1

G3 2500A 2500 75 E3S 2500A FP HR + MP 1SDA063836R1

G3 3000A 3000 75 E3S 3200A FP HR + MP 1SDA063837R1

G4 3200A 3200 75 E3S 3200A FP HR + MP 1SDA063840R1

Megamax 3 poles

EMAX 3 poles

Version

F1B 1250A 1250 40 E1B 1250A FP HR + MP 1SDA063802R1

F1B 1600A 1600 40 E1B 1600A FP HR + MP 1SDA063802R1

F1B 2000A 2000 40 E2B 2000A FP HR + MP 1SDA063809R1

F1N 1250A 1250 50 E1N 1250A FP HR + MP 1SDA063802R1

F1N 1600A 1600 50 E1N 1600A FP HR + MP 1SDA063802R1

F1N 2000A 1600 50 E2N 2000A FP HR + MP 1SDA063809R1

F1S 1250A 1250 55 E2N 1250A FP HR + MP 1SDA063807R1

F1S 1600A 1600 55 E2N 1600A FP HR + MP 1SDA063807R1

F1S 2000A 2000 55 E2N 2000A FP HR + MP 1SDA063809R1

F1H 1250A 1250 85 E2S 1250A FP HR + MP 1SDA063810R1

F1H 1600A 1600 85 E2S 1600A FP HR + MP 1SDA063810R1

F1L/V 1250A 1250 130 E2L 1250A FP HR + MP 1SDA063811R1

F1L/V 1600A 1600 130 E2L 1600A FP HR + MP 1SDA063811R1

F2H 2000A 2000 85 E2S 2000A FP HR + MP 1SDA063823R1

F2H 2500A 2500 85 E3H 2500A FP HR + MP 1SDA063824R1

F2S 2500A 2500 65 E3N 2500A FP HR + MP 1SDA063826R1

F2S 3000A 3000 65 E3N 3000A FP HR + MP 1SDA063826R1

F2L/V 2000A 2000 130 E3L 2000A FP HR + MP 1SDA063825R1

F2L/V 2500A 2500 130 E3L 2500A FP HR + MP 1SDA063825R1

F3S 2000A 2000 75 E3S 2000A FP HR + MP 1SDA063836R1

F3S 2500A 2500 75 E3S 2500A FP HR + MP 1SDA063836R1

F3S 3000A 3000 75 E3S 3200A FP HR + MP 1SDA063837R1

F4S 3200A 3200 80 E3S 3200A FP HR + MP 1SDA063840R1

Air circuit-breakers kit

ALL THE RETROFITTING KITS HAVE BEEN STUDIED FOR REPLACEMENT OF OLD CIRCUIT- BREAKERS INSTALLED AS PER INDICATED IN THE INSTRUCTION MANUALS.

NOTEKit available only complete with the new circuit-breaker. Air circuit-breaker retrofi tting kit has been studied for Novomax G and Megamax circuit-breaker in draw out version with rear horizontal terminals. Contact us if the installed circuit-breakers are in different version.

For Novomax G2 and Megamax F1 the retrofi tting kit are fi tted into the old breakers’ fi xed part for prompt insertion. Kit available only assembled on the new circuit-breaker.

MAIN ACTIVITIES REQUIRED :• Put out of service the panel or the entire switchboard• Carry out the moving part of the Novomax / Megamax circuit-breaker• Remove the fi xed part of the Novomax/Megamax circuit-breaker• On a workbench fi t the branch connections to the fi xed part of the Emax circuit-breaker• Assembly the Emax fi xed part with retrofi tting kit in the switchboard compartment• Drill the cut of the front door panel

MAIN ACTIVITIES REQUIRED FOR NOVOMAX G2 AND MEGAMAX F1• Put out of service the panel or the entire switchboard• Carry out the moving part of the Novomax G2 / Megamax F1 circuit-breaker• Install the new Emax circuit-breaker complete with the retrofi tting kit• Drillng templates of the compartment door

07 Retrofitting_INT.indd 2007 Retrofitting_INT.indd 20 28-06-2006 10:58:0828-06-2006 10:58:08

Page 22: Technical catalogue Retrofi tting kits - ABB Group · support ABB SACE Technical catalogue ... ABB SACE S.p.A. is a company in ABB group which has been operating in the ... The use

21ABB SACE

Retrofi tting kitsOrdering codes

Old circuit-breaker

Iu[A]

Icu[kA] New circuit-breaker Retrofi tting kit code

Novomax4 poles

EMAX 4 poles

Version

G30 800A 800 35 E1B 800A FP HR + MP 1SDA050760R1

G30 1250A 1250 35 E1B 1250A FP HR + MP 1SDA050760R1

G30 1600A 1600 35 E2B 1600A FP HR + MP 1SDA050759R1

G2 1250A 1250 50 E1N 1250A FP HR + MP 1SDA063821R1

G2 1600A 1600 50 E1N 1600A FP HR + MP 1SDA063821R1

G2 2000A 2000 50 E2N 2000A FP HR + MP 1SDA063822R1

G2 2500A 2500 45 E3N 2500A FP HR + MP 1SDA063833R1

G3 2000A 2000 75 E3S 2000A FP HR + MP 1SDA063838R1

G3 2500A 2500 75 E3S 2500A FP HR + MP 1SDA063838R1

G3 3000A 3000 75 E3S 3200A FP HR + MP 1SDA063839R1

G4 3200A 3200 75 E3S 3200A FP HR + MP 1SDA063841R1

Megamax 4 poles

EMAX 4 poles

Version

F1B 1250A 1250 40 E1B 1250A FP HR + MP 1SDA063812R1

F1B 1600A 1600 40 E1B 1600A FP HR + MP 1SDA063812R1

F1B 2000A 2000 40 E2B 2000A FP HR + MP 1SDA063816R1

F1N 1250A 1250 50 E1N 1250A FP HR + MP 1SDA063812R1

F1N 1600A 1600 50 E1N 1600A FP HR + MP 1SDA063812R1

F1N 2000A 1600 50 E2N 2000A FP HR + MP 1SDA063816R1

F1S 1250A 1250 55 E2N 1250A FP HR + MP 1SDA063814R1

F1S 1600A 1600 55 E2N 1600A FP HR + MP 1SDA063814R1

F1S 2000A 2000 55 E2N 2000A FP HR + MP 1SDA063816R1

F1H 1250A 1250 85 E2S 1250A FP HR + MP 1SDA063817R1

F1H 1600A 1600 85 E2S 1600A FP HR + MP 1SDA063817R1

F1L/V 1250A 1250 130 E2L 1250A FP HR + MP 1SDA063818R1

F1L/V 1600A 1600 130 E2L 1600A FP HR + MP 1SDA063818R1

F2H 2000A 2000 85 E2S 2000A FP HR + MP 1SDA063827R1

F2H 2500A 2500 85 E3H 2500A FP HR + MP 1SDA063829R1

F2S 2500A 2500 65 E3N 2500A FP HR + MP 1SDA063833R1

F2S 3000A 3000 65 E3N 3000A FP HR + MP 1SDA063833R1

F2L/V 2000A 2000 130 E3L 2000A FP HR + MP 1SDA063832R1

F2L/V 2500A 2500 130 E3L 2500A FP HR + MP 1SDA063832R1

F3S 2000A 2000 75 E3S 2000A FP HR + MP 1SDA063838R1

F3S 2500A 2500 75 E3S 2500A FP HR + MP 1SDA063838R1

F3S 3000A 3000 75 E3S 3200A FP HR + MP 1SDA063839R1

F4S 3200A 3200 80 E3S 3200A FP HR + MP 1SDA063841R1

Air circuit-breakers kit

ALL THE RETROFITTING KITS HAVE BEEN STUDIED FOR REPLACEMENT OF OLD CIRCUIT- BREAKERS INSTALLED AS PER INDICATED IN THE INSTRUCTION MANUALS.

NOTEKit available only complete with the new circuit-breaker. Air circuit-breaker retrofi tting kit has been studied for Novomax G and Megamax circuit-breaker in draw out version with rear horizontal terminals. Contact us if the installed circuit-breakers are in different version.

For Novomax G2 and Megamax F1 the retrofi tting kit are fi tted into the old breakers’ fi xed part for prompt insertion. Kit available only assembled on the new circuit-breaker.

MAIN ACTIVITIES REQUIRED :• Put out of service the panel or the entire switchboard• Carry out the moving part of the Novomax / Megamax circuit-breaker• Remove the fi xed part of the Novomax/Megamax circuit-breaker• On a workbench fi t the branch connections to the fi xed part of the Emax circuit-breaker• Assembly the Emax fi xed part with retrofi tting kit in the switchboard compartment• Drill the cut of the front door panel

MAIN ACTIVITIES REQUIRED FOR NOVOMAX G2 AND MEGAMAX F1• Put out of service the panel or the entire switchboard• Carry out the moving part of the Novomax G2 / Megamax F1 circuit-breaker• Install the new Emax circuit-breaker complete with the retrofi tting kit• Drillng templates of the compartment door

07 Retrofitting_INT.indd 2107 Retrofitting_INT.indd 21 28-06-2006 10:58:0928-06-2006 10:58:09

Page 23: Technical catalogue Retrofi tting kits - ABB Group · support ABB SACE Technical catalogue ... ABB SACE S.p.A. is a company in ABB group which has been operating in the ... The use

22 ABB SACE

Retrofi tting kitsOrdering codes

Old circuit-breaker

Iu[A]

Icu[kA] New circuit-breaker Retrofi tting kit code

Novomax G303 poles

Isomax 3 poles Version

G30 800A 800 35 S7S 1250 FP VR + MP 1SDA063773R1

G30 1250A 1250 35 S7S 1250 FP VR + MP 1SDA063773R1

G30 1600A 1600 35 S7S 1600 FP VR + MP 1SDA063775R1

Hybrid retrofi tting kit

Old circuit-breaker

Iu[A]

Icu[kA] New circuit-breaker Retrofi tting kit code

Novomax G304 poles

Isomax 4 poles Version

G30 800A 800 35 S7S 1250 FP VR + MP 1SDA063774R1

G30 1250A 1250 35 S7S 1250 FP VR + MP 1SDA063774R1

G30 1600A 1600 35 S7S 1600 FP VR + MP 1SDA063776R1

Old circuit-breaker

Iu[A]

Icu[kA] New circuit-breaker Retrofi tting kit code

Otomax3 poles

Isomax 3 poles Version

P1C-P2C 1250 1250 35 S7H 1250 FP VR + MP 1SDA063769R1

P1C-P2C 1600 1600 35 S7H 1600 FP VR + MP 1SDA063770R1

Old circuit-breaker

Iu[A]

Icu[kA] New circuit-breaker Retrofi tting kit code

Otomax3 poles + neutral

Isomax 3 poles Version

P1C-P2C 1250 1250 35 S7H 1250 FP VR + MP 1SDA063771R1

P1C-P2C 1600 1600 35 S7H 1600 FP VR + MP 1SDA063772R1

ALL THE RETROFITTING KITS HAVE BEEN STUDIED FOR REPLACEMENT OF OLD CIRCUIT- BREAKERS INSTALLED AS PER INDICATED IN THE INSTRUCTION MANUALS.

NOTEKit available only complete with the new circuit-breaker. Air circuit-breaker retrofi tting kit has been studied for Otomax and Novomax G30 circuit-breaker in draw out version with rear horizontal terminals. Contact us if the installed circuit-breakers are in different version.

MAIN ACTIVITIES REQUIRED :• Put out of service the panel or the entire switchboard• Carry out the moving part of the Otomax / Novomax circuit-breaker• Install the new moulded case circuit-breaker type Isomax S7 complete with the retrofi tting kit• Check the auxiliary and install external relays if necessary • Drillng templates of the compartment door

07 Retrofitting_INT.indd 2207 Retrofitting_INT.indd 22 28-06-2006 10:58:1028-06-2006 10:58:10

Page 24: Technical catalogue Retrofi tting kits - ABB Group · support ABB SACE Technical catalogue ... ABB SACE S.p.A. is a company in ABB group which has been operating in the ... The use

23ABB SACE

Retrofi tting kitsOrdering codes

Old circuit-breaker

Iu[A]

Icu[kA] New circuit-breaker Retrofi tting kit code

Isol3 poles

Isomax 3 poles Version

Z320 250A 250 25 S4N 250A FP R + MP UXAB129599101Z320 320A 320 25 S5N 400A FP VR + MP UXAB129599101

Z500 500A 500 25 S5N 630A FP VR + MPUXAB129699101UXAB129699102

Z630 400A 400 25 S6S 630A FP VR + MP UXAB129799101Z630 500A 500 25 S6S 630A FP VR + MP UXAB129799101Z630 630A 630 25 S6S 630A FP VR + MP UXAB129799101Z800 800A 800 25 S6S 800A FP R + MP UXAB129899101

Old circuit-breaker

Iu[A]

Icu[kA] New circuit-breaker Retrofi tting kit code

Fusol3 poles

Isomax 3 poles Version

Fusol FZ630 400A 400 100 S6L 630A FP VR + MP UXAB139599101Fusol FZ630 500A 500 100 S6L 630A FP VR + MP UXAB139599101Fusol FZ630 630A 630 100 S6L 630A FP VR + MP UXAB139599101

Old circuit-breaker

Iu[A]

Icu[kA] New circuit-breaker Retrofi tting kit code

Modul3 poles

TmaxIsomax 3 poles Version

SN100 PMP 100 30 T2N160 FP F + MP 1SDA063777R1SN125 PMP 125 30 T2N160 FP F + MP 1SDA063777R1SN160 PMP 160 35 T4N250 FP F + MP 1SDA063778R1SN250 PMP 250 35 T4N250 FP F + MP 1SDA063778R1SN400 PMP 400 35 T5N400 FP F + MP 1SDA063779R1SN1250 WMP R 1000 1250 50 S7S 1250 FF R 1000 UXAB149199101SN1250 WMP R 1250 1250 50 S7S 1250 FF R 1250 UXAB149199101SN1600 WMP R 1600 1600 50 S7S 1600 FF R 1600 UXAB149199103SH100 PMP 100 60 T4H250 FP F + MP 1SDA063780R1SH125 PMP 125 60 T4H250 FP F + MP 1SDA063780R1SH160 PMP 160 60 T4H250 FP F + MP 1SDA063781R1SH250 PMP 250 60 T4H250 FP F + MP 1SDA063781R1SH400 PMP 400 60 T5H400 FP F + MP 1SDA063782R1SH1250 WMP R 1000 1250 70 S7L 1250 FF R 1000 UXAB149199101SH1250 WMP R 1250 1250 70 S7L 1250 FF R 1250 UXAB149199101SH1600 WMP R 1600 1600 70 S7L 1600 FF R 1600 UXAB149199103

Old circuit-breaker

Iu[A]

Icu[kA] New circuit-breaker Retrofi tting kit code

Modul

4 poles

TmaxIsomax 4 poles Version

SN100 PMP 100 30 T2N160 FP F + MP 1SDA063783R1 SN125 PMP 125 30 T2N160 FP F + MP 1SDA063783R1 SN160 PMP 160 35 T4N250 FP F + MP 1SDA063784R1 SN250 PMP 250 35 T4N250 FP F + MP 1SDA063784R1 SN400 PMP 400 35 T5N400 FP F + MP 1SDA063785R1 SN1250 WMP R 1000 1250 50 S7S 1250 FF R 1000 UXAB149199102 SN1250 WMP R 1250 1250 50 S7S 1250 FF R 1250 UXAB149199102 SN1600 WMP R 1600 1600 50 S7S 1600 FF R 1600 UXAB149199104 SH100 PMP 100 60 T4H250 FP F + MP 1SDA063786R1 SH125 PMP 125 60 T4H250 FP F + MP 1SDA063786R1 SH160 PMP 160 60 T4H250 FP F + MP 1SDA063787R1 SH250 PMP 250 60 T4H250 FP F + MP 1SDA063787R1 SH400 PMP 400 60 T5H400 FP F + MP 1SDA063788R1 SH1250 WMP R 1000 1250 70 S7L 1250 FF R 1000 UXAB149199102 SH1250 WMP R 1250 1250 70 S7L 1250 FF R 1250 UXAB149199102 SH1600 WMP R 1600 1600 70 S7L 1600 FF R 1600 UXAB149199104

Moulded-case retrofi tting kit

ALL THE RETROFITTING KITS HAVE BEEN STUDIED FOR REPLACEMENT OF OLD CIRCUIT- BREAKERS INSTALLED AS PER INDICATED IN THE INSTRUCTION MANUALS.

NOTEMoulded case retrofi tting kit are fi tted into the old breakers’ fi xed part for prompt insertion. Kit available only assembled on the new circuit-breaker. The depth of the installation kit will be increased.Contact us if the installed circuit-breakers are in different version.

MAIN ACTIVITIES REQUIRED • Put out of service the panel or the entire switchboard• Carry out the moving part of the Modul / Isol / Fusol circuit-breaker• Install the new molded case circuit-breaker type Isomax or Tmax complete with the retrofi tting kit• Drillng templates of the compartment door

07 Retrofitting_INT.indd 2307 Retrofitting_INT.indd 23 28-06-2006 10:58:1028-06-2006 10:58:10

Page 25: Technical catalogue Retrofi tting kits - ABB Group · support ABB SACE Technical catalogue ... ABB SACE S.p.A. is a company in ABB group which has been operating in the ... The use

REFERENCE• Retrofi tting of circuit-brekers on-board shipping installations • Retrofi tting of Otomax and Novomax for Power plant • Retrofi tting Austrian Hydro power plant • Retrofi tting of Cementeria Italcementi Italy • Retrofi tting of Fiat Group Factory in Italy and Brazil • Retrofi tting of petrolchemical factory, Italy • Retrofi tting of circuit-breakers in oil platform in Norway

ABB SACE’s Technical Assistance is available to study migration proposal

for non Standard Applications.

07 Retrofitting_INT.indd 2407 Retrofitting_INT.indd 24 28-06-2006 10:58:1228-06-2006 10:58:12

Page 26: Technical catalogue Retrofi tting kits - ABB Group · support ABB SACE Technical catalogue ... ABB SACE S.p.A. is a company in ABB group which has been operating in the ... The use

1SD

C00

1008

D02

01 -

06/

2006

P

rinte

d in

Ital

y2.

000

- C

AL

ABB SACE S.p.A.An ABB Group company

L.V. BreakersVia Baioni, 3524123 Bergamo - ItalyTel.: +39 035.395.111 - Telefax: +39 035.395.306-433

http://www.abb.com

Due to possible developments of standards as well as of materials, the characteristics and dimensions specified in the present catalogue may only be considered binding after confi rmation by ABB SACE.

07 Retrofitting_COP.indd 207 Retrofitting_COP.indd 2 28-06-2006 10:41:1228-06-2006 10:41:12