technical specification for alkaline · pdf fileultra max batteries, watkins house pegamoid...
TRANSCRIPT
Ultra Max Batteries, Watkins House Pegamoid Rd., Montagu Industrial Estate, London N18 2NG Tel: 020 8803 8899 F: 020 8803 8939 E: [email protected] W: www.ultramaxbatteries.com
WATUMX30-TEC-FEN-F15
TECHNICAL SPECIFICATION FOR
ALKALINE MANGANESE BUTTON CELL
BATTERY SERIES-LR621 BUTTON CELL
APPROVED SIGNATURE :
YOUR NAME
TITLE :
DATE :
Typed :
Approved :
Ultra Max Batteries, Watkins House Pegamoid Rd., Montagu Industrial Estate, London N18 2NG Tel: 020 8803 8899 F: 020 8803 8939 E: [email protected] W: www.ultramaxbatteries.com
WATUMX30-TEC-FEN-F15
1. Summary
The technical specification applies to 1.5V LR1130 alkaline manganese made by
ULTRA MAX BATTERIES
1.1 Model Control
FB Battery.:LR621 Other Designate:AG1 IEC:LR60 JIS: LR621 ANSI:--
1.2 Reference Standards
IEC 60086-1(2000-11)- primary batteries –Part 1:General IEC 60086-1(2001-10)- primary batteries –Part 2:Physical and Electrical Specification IEC 60086-1(2000-07)- primary batteries –Part 5:Safety of batteries with aqueous
electrolyte 2. Chemical Composition: Zn(-) / MnO2 (C) (+)
3. Nominal Voltage:1.50V
4. Short Circuit Current:100-250mA
5. Average Weight:0.25g
6. Nominal Capacity:12mAh(Discharge condition:Discharge 24 hours every day under 20
±2℃,68kΩ,termination voltage 1.2V)
7. Battery Performance:
No-load Voltage(V) Load Voltage(V) Acceptance Standard
Production 1.53 1.52 MIL-STD105E,ClassⅡ,
Double Sampling ,AQL=0.4
(Condition:After receiving 30 days, measure 0.3 seconds under 20±2℃, 68kΩ)
8. Discharge Time
Discharge Condition Min average discharge time
discharge resistance resistance
Discharge Times(D)
termination Voltage Production
Room temperature for 1 year
Standard
68kΩ 24 h 1.2V 480h 440h
7.5kΩ 24 h 0.9V 84 h 76h
(condition:After receiving 30 days under 20±2℃)
Acceptance Standard:
1)Each batch take nine cells for discharge test;
2)Average discharge time must be equal to or greater than the Min average discharge time. If
Ultra Max Batteries, Watkins House Pegamoid Rd., Montagu Industrial Estate, London N18 2NG Tel: 020 8803 8899 F: 020 8803 8939 E: [email protected] W: www.ultramaxbatteries.com
WATUMX30-TEC-FEN-F15
the batteries number which less than 90% of the discharge time are more than one, judge as
qualified.
3)If the above results are not qualified, test again please.
9. Safety Performance
item environmental conditions deadline require Acceptance Standard
External Short-Circuit
Test 20±2℃ 24 hours Battery won't
appear explosion N=9,Ac=0;Re=1
10. Mark
The bottom of battery shell has the following content:
1) Battery Type:LR621
2) Manufacturer:FB
3) Polarity sign: “+”
4) Battery name:BUTTON CELL
11. Notes
1) Please don’t charge the battery; it may cause leakage and damaging the charging equipment.
2) Please install batteries exactly
3) Don’t short circuit, heat the battery.
4) Don’t disassemble the battery; the internal electrolyte will corrupt the skin
5) Don’t use new electricity and have used batteries at the same time
6) Pease take the drained batteries out from appliances, avoiding leakage resulted from discharge.
7) The battery should keep away from children, beware of swallowing.
8) In order to use and protect appliances better, wipes cover face with alcohol before taking in appliances.
12. Storage Period
1) Storing for one year In normal and reasonable environment(20±2℃,55±20%)
2) Battery capacity can be kept more than 90% in one year storage period
13. Discharge Curve (Testing temperature :20±2℃)
1) Discharge method: Discharge 24 hours per day under 68kΩ(schedule 1)
2) Discharge method: Discharge 24 hours per day under 7.5kΩ(schedule 2)
14.Battery Shape Dimension Drawing (Appended drawings )
Ultra Max Batteries, Watkins House Pegamoid Rd., Montagu Industrial Estate, London N18 2NG Tel: 020 8803 8899 F: 020 8803 8939 E: [email protected] W: www.ultramaxbatteries.com
WATUMX30-TEC-FEN-F15
15.Battery Chart (Appended drawings)
schedule 1 Discharge Characteristics LR621 under 68 kΩ
schedule 2 Discharge Characteristics LR621 under 7.5 kΩ
Ultra Max Batteries, Watkins House Pegamoid Rd., Montagu Industrial Estate, London N18 2NG Tel: 020 8803 8899 F: 020 8803 8939 E: [email protected] W: www.ultramaxbatteries.com
WATUMX30-TEC-FEN-F15
Ultra Max Batteries, Watkins House Pegamoid Rd., Montagu Industrial Estate, London N18 2NG Tel: 020 8803 8899 F: 020 8803 8939 E: [email protected] W: www.ultramaxbatteries.com
WATUMX30-TEC-FEN-F15
TECHNICAL SPECIFICATION FOR
ALKALINE MANGANESE BUTTON
CELL
BATTERY SERIES-LR1130 BUTTON
CELL
APPROVED SIGNATURE :
YOUR NAME
TITLE :
DATE :
Typed :
Approved :
Ultra Max Batteries, Watkins House Pegamoid Rd., Montagu Industrial Estate, London N18 2NG Tel: 020 8803 8899 F: 020 8803 8939 E: [email protected] W: www.ultramaxbatteries.com
WATUMX30-TEC-FEN-F15
1. Summary
The technical specification applies to 1.5V LR1130 alkaline manganese made by
ULTRA MAX BATTERIES 1.1 Model Control
FB Battery.:LR41 Other Designate:AG3
IEC:LR41 JIS: LR736 ANSI:-- 1.2 Reference Standards
IEC 60086-1(2000-11)- primary batteries –Part 1:General
IEC 60086-1(2001-10)- primary batteries –Part 2:Physical and Electrical
Specification
IEC 60086-1(2000-07)- primary batteries –Part 5:Safety of batteries with
aqueous electrolyte
2. Chemical Composition: Zn( -) / MnO2 (C) (+)
3. Nominal Voltage:1.50V
4. Short Circuit Current:200-400mA
5. Average Weight:0.60g
6. Nominal Capacity:
28mAh(Discharge condition:Discharge 24 hours every day under 20±2℃,22k
Ω,termination voltage 1.2V)
7. Battery Performance:
No-load Voltage(V) Load Voltage(V) Acceptance Standard
Production 1.55 1.54 MIL-STD105E,ClassⅡ,
Double Sampling ,AQL=0.4
(Condition:After receiving 30 days, measure 0.3 seconds under 20±2℃, 22kΩ)
8. Discharge Time
Discharge Condition Min average discharge time
Ultra Max Batteries, Watkins House Pegamoid Rd., Montagu Industrial Estate, London N18 2NG Tel: 020 8803 8899 F: 020 8803 8939 E: [email protected] W: www.ultramaxbatteries.com
WATUMX30-TEC-FEN-F15
discharge resistance
Discharge Times(D) termination
Voltage Production
Room temperature for 1 year
Standard
22kΩ 24 h 1.2V 480h 440h
1.5kΩ 24 h 0.9V 38 h 34h
(condition:After receiving 30 days under 20±2℃)
Acceptance Standard:
1)Each batch take nine cells for discharge test;
2)Average discharge time must be equal to or greater than the Min average
discharge time. If the batteries number which less than 90% of the discharge time
are more than one, judge as qualified.
3)If the above results are not qualified, test again please.
9. Safety Performance
item environmental conditions deadline require Acceptance
Standard External
Short-Circuit Test
20±2℃ 24 hours Battery won't
appear explosion
N=9,Ac=0;Re=1
10. Mark
The bottom of battery shell has the following content:
1) Battery Type:LR41
2) Manufacturer:FB
3) Polarity sign: “+”
4) Battery name:BUTTON CELL
11.Notes
1) Please don’t charge the battery, it may cause leakage and damaging the charging
equipment.
2) Please install batteries exactly
Ultra Max Batteries, Watkins House Pegamoid Rd., Montagu Industrial Estate, London N18 2NG Tel: 020 8803 8899 F: 020 8803 8939 E: [email protected] W: www.ultramaxbatteries.com
WATUMX30-TEC-FEN-F15
3) don’t short circuit, heat the battery.
4) Don’t disassemble the battery; the internal electrolyte will corrupt the skin
5) Don’t use new electricity and have used batteries at the same time
6) Pease take the drained batteries out from appliances, avoiding leakage resulted from
discharge.
7) The battery should keep away from children, beware of swallowing.
8) In order to use and protect appliances better, wipes cover face with alcohol before taking
in appliances.
12. Storage Period
1) Storing for one year In normal and reasonable environment (20±2℃,55±20%)
2) Battery capacity can be kept more than 90% in one year storage period
13. Discharge Curve (Testing temperature :20±2℃)
1) Discharge method: Discharge 24 hours per day under 22kΩ(schedule 1)
2) Discharge method: Discharge 24 hours per day under 1.5kΩ(schedule 2)
14. Battery Shape Dimension Drawing(Appended drawings )
15. Battery Chart (Appended drawings)
Schedule 1 Discharge Characteristics LR41 under 22 kΩ
Ultra Max Batteries, Watkins House Pegamoid Rd., Montagu Industrial Estate, London N18 2NG Tel: 020 8803 8899 F: 020 8803 8939 E: [email protected] W: www.ultramaxbatteries.com
WATUMX30-TEC-FEN-F15
Schedule 2 Discharge Characteristics LR41 under 1500Ω
Ultra Max Batteries, Watkins House Pegamoid Rd., Montagu Industrial Estate, London N18 2NG Tel: 020 8803 8899 F: 020 8803 8939 E: [email protected] W: www.ultramaxbatteries.com
WATUMX30-TEC-FEN-F15
TECHNICAL SPECIFICATION FOR
ALKALINE MANGANESE BUTTON
CELL
BATTERY SERIES-LR626 BUTTON
CELL
APPROVED SIGNATURE :
YOUR NAME
TITLE :
DATE :
Typed :
Approved :
Ultra Max Batteries, Watkins House Pegamoid Rd., Montagu Industrial Estate, London N18 2NG Tel: 020 8803 8899 F: 020 8803 8939 E: [email protected] W: www.ultramaxbatteries.com
WATUMX30-TEC-FEN-F15
1. Summary
The technical specification applies to 1.5V LR626 alkaline manganese made by ULTRA MAX BATTERIES
1.1 Model Control
FB Battery.:LR626 Other Designate:AG4
IEC:LR66 JIS: LR626 ANSI:--
1.2 Reference Standards
IEC 60086-1(2000-11)- primary batteries –Part 1:General
IEC 60086-1(2001-10)- primary batteries –Part 2:Physical and Electrical
Specification
IEC 60086-1(2000-07)- primary batteries –Part 5:Safety of batteries with
aqueous electrolyte
2. Chemical Composition: Zn( -) / MnO2 (C) (+)
3. Nominal Voltage:.50V
4. Short Circuit Current:100-250mA
5. Average Weight:0.31g
6. Nominal Capacity:
17mAh(Discharge condition:Discharge 24 hours every day under 20±2℃,47k
Ω,termination voltage 1.2V)
7. Battery Performance:
No-load
Voltage(V)
Load Voltage
(V) Acceptance Standard
Production 1.53 1.52 MIL-STD105E,ClassⅡ,
Double Sampling ,AQL=0.4
(Condition:After receiving 30 days, measure 0.3 seconds under 20±2℃, 47kΩ)
8. Discharge Time
Discharge Condition Min average discharge
time discharge
resistance
resistance
Discharge
Times(D)
termination
Voltage Production Room
temperat
ure for 1
year Standard
47kΩ 24 h 1.2V 530h 480h
7.5kΩ 24 h 0.9V 118 h 108h
(condition:After receiving 30 days under 20±2℃)
Ultra Max Batteries, Watkins House Pegamoid Rd., Montagu Industrial Estate, London N18 2NG Tel: 020 8803 8899 F: 020 8803 8939 E: [email protected] W: www.ultramaxbatteries.com
WATUMX30-TEC-FEN-F15
Acceptance Standard:
1)Each batch take nine cells for discharge test;
2)Average discharge time must be equal to or greater than the Min average
discharge time. If the batteries number which less than 90% of the discharge
time are more than one, judge as qualified.
3)If the above results are not qualified, test again please.
9. Safety Performance
item environmental
conditions deadline require
Acceptance
Standard
External
Short-Circuit
Test
20±2℃ 24 hours
Battery won't
appear
explosion
N=9,Ac=0;
Re=1
10. Mark
The bottom of battery shell has the following content:
1) Battery Type:LR626
2) Manufacturer:FB
3) Polarity sign: “+”
4) Battery name:BUTTON CELL
11. Notes
1) Please don’t charge the battery; it may cause leakage and damaging the charging
equipment.
2) Please install batteries exactly
3) Don’t short circuit, heat the battery.
4) Don’t disassemble the battery; the internal electrolyte will corrupt the skin
5) Don’t use new electricity and have used batteries at the same time
6) Pease take the drained batteries out from appliances, avoiding leakage resulted from
discharge.
7) The battery should keep away from children, beware of swallowing.
8) In order to use and protect appliances better, wipes cover face with alcohol before
taking in appliances.
12. Storage Period
1) Storing for one year In normal and reasonable environment(20±2℃,55±20%)
Ultra Max Batteries, Watkins House Pegamoid Rd., Montagu Industrial Estate, London N18 2NG Tel: 020 8803 8899 F: 020 8803 8939 E: [email protected] W: www.ultramaxbatteries.com
WATUMX30-TEC-FEN-F15
2) Battery capacity can be kept more than 90% in one year storage period
13. Discharge Curve (Testing temperature :20±2℃)
1) Discharge method: Discharge 24 hours per day under 47kΩ(schedule 1)
2) Discharge method: Discharge 24 hours per day under 7。5kΩ(schedule 2)
14. Battery Shape Dimension Drawing (Appended drawings )
15. Battery Chart (Appended drawings)
Schedule 1 (Discharge Characteristics LR626 under 47 kΩ)
Schedule 2 (Discharge Characteristics LR626 under 7.5 kΩ)
Ultra Max Batteries, Watkins House Pegamoid Rd., Montagu Industrial Estate, London N18 2NG Tel: 020 8803 8899 F: 020 8803 8939 E: [email protected] W: www.ultramaxbatteries.com
WATUMX30-TEC-FEN-F15
Ultra Max Batteries, Watkins House Pegamoid Rd., Montagu Industrial Estate, London N18 2NG Tel: 020 8803 8899 F: 020 8803 8939 E: [email protected] W: www.ultramaxbatteries.com WATUMX30-TEC-FEN-F15
TECHNICAL SPECIFICATION FOR
ALKALINE MANGANESE BUTTON CELL
BATTERY SERIES-LR1130 BUTTON CELL
APPROVED SIGNATURE :
YOUR NAME
TITLE :
DATE :
Typed :
Approved :
Ultra Max Batteries, Watkins House Pegamoid Rd., Montagu Industrial Estate, London N18 2NG Tel: 020 8803 8899 F: 020 8803 8939 E: [email protected] W: www.ultramaxbatteries.com WATUMX30-TEC-FEN-F15
1. Summary
The technical specification applies to 1.5V alkaline manganese made by
ULTRA MAX BATTERIES
1.1 Model Control
FB Battery.:LR1130 Other Designate:AG10
IEC:LR54 JIS: LR1130 ANSI:--
1.2 Reference Standards
IEC 60086-1(2000-11)- primary batteries –Part 1:General
IEC 60086-1(2001-10)- primary batteries –Part 2:Physical and Electrical Specification
IEC 60086-1(2000-07)- primary batteries –Part 5:Safety of batteries with aqueous electrolyte
2. Chemical Composition: Zn (-) / MnO2 (C) (+)
3. Nominal Voltage:1.50V
4. Short Circuit Current:300-800mA
5. Average Weight:1.11g
6. Nominal Capacity:
58mAh(Discharge condition:Discharge 24 hours every day under 20±2℃,15kΩ,termination
voltage 1.2V)
7. Battery Performance:
No-load
Voltage(V) Load Voltage(V) Acceptance Standard
Production 1.55 1.54 MIL-STD105E,ClassⅡ,
Double Sampling ,AQL=0.4
(Condition:After receiving 30 days, measure 0.3 seconds under 20±2℃, 15kΩ)
8. Discharge Time
Discharge Condition Min average discharge time
discharge
resistance
resistance
Discharge
Times(D) termination
Voltage Production
Room temperature
for 1 year
Standard 15kΩ 24 h 1.2V 510h 460h
1kΩ 24 h 0.9V 50 h 46h
(condition:After receiving 30 days under 20±2℃)
Acceptance Standard:
1)Each batch take nine cells for discharge test;
Ultra Max Batteries, Watkins House Pegamoid Rd., Montagu Industrial Estate, London N18 2NG Tel: 020 8803 8899 F: 020 8803 8939 E: [email protected] W: www.ultramaxbatteries.com WATUMX30-TEC-FEN-F15
2)Average discharge time must be equal to or greater than the Min average discharge time. If the
batteries number which less than 90% of the discharge time are more than one, judge as qualified.
3)If the above results are not qualified, test again please.
Technical Specification SK-1130-2009D P2/4
9. Safety Performance
item environmental
conditions deadline require Acceptance Standard
External
Short-Circuit
Test
20±2℃ 24 hours Battery won't
appear explosion N=9,Ac=0;Re=1
10. Mark The bottom of battery shell has the following content:
1) Battery Type:LR1130
2) Manufacturer:FB
3) Polarity sign: “+”
4) Battery name:BUTTON CELL
11. Notes
1) Please don’t charge the battery; it may cause leakage and damaging the charging equipment.
2) Please install batteries exactly
3) Don’t short -circuit, heat the battery.
4) Don’t disassemble the battery; the internal electrolyte will corrupt the skin
5) Don’t use new electricity and have used batteries at the same time
6) Pease take the drained batteries out from appliances, avoiding leakage resulted from discharge.
7) The battery should keep away from children, beware of swallowing.
8) In order to use and protect appliances better, wipes cover face with alcohol before taking in appliances.
12. Storage Period
1) Storing for one year In normal and reasonable environment(20±2℃,55±20%)
2) Battery capacity can be kept more than 90% in one year storage period
13. Discharge Curve (Testing temperature :20±2℃)
1) Discharge method: Discharge 24 hours per day under 15kΩ(schedule 1)
2) Discharge method: Discharge 24 hours per day under 1kΩ(schedule 2)
14.Battery Shape Dimension Drawing (Appended drawings )
15.Battery Chart (Appended drawings)
Schedule 1 Discharge Characteristics LR1130 under 15 kΩ
Ultra Max Batteries, Watkins House Pegamoid Rd., Montagu Industrial Estate, London N18 2NG Tel: 020 8803 8899 F: 020 8803 8939 E: [email protected] W: www.ultramaxbatteries.com
WATUMX30-TEC-FEN-F15
TECHNICAL SPECIFICATION FOR
ALKALINE MANGANESE BUTTON CELL
BATTERY SERIES-LR44 BUTTON CELL
APPROVED SIGNATURE :
YOUR NAME
TITLE :
DATE :
Typed :
Approved :
Ultra Max Batteries, Watkins House Pegamoid Rd., Montagu Industrial Estate, London N18 2NG Tel: 020 8803 8899 F: 020 8803 8939 E: [email protected] W: www.ultramaxbatteries.com
WATUMX30-TEC-FEN-F15
Summary
The technical specification applies to 1.5V LR44 alkaline manganese made by ULTRA MAX BATTERIES
1.1 Model Control
FB Battery.:LR1130 Other Designate:AG13 IEC:LR44 JIS: LR1154 ANSI:--
1.2 Reference Standards
IEC 60086-1(2000-11)- primary batteries –Part 1:General IEC 60086-1(2001-10)- primary batteries –Part 2:Physical and Electrical Specification IEC 60086-1(2000-07)- primary batteries –Part 5:Safety of batteries with aqueous electrolyte
2. Chemical Composition: Zn( -) / MnO2 (C) (+)
3. Nominal Voltage:1.50V
4. Short Circuit Current:300-900mA
5. Average Weight: 1.95g
6. Nominal Capacity:
130mAh(Discharge condition:Discharge 24 hours every day under 20±2℃,6.8kΩ,termination
voltage 1.2V)
7. Battery Performance:
No-load Voltage(V) Load Voltage(V) Acceptance Standard
Production 1.55 1.54 MIL-STD105E,ClassⅡ,
Double Sampling ,AQL=0.4
Discharge Condition Min average discharge time
discharge resistance
Discharge Times(D)
termination Voltage Production
Room temperature for 1 year
Standard
6.8kΩ 24 h 1.2V 520h 470h
1kΩ 24 h 0.9V 108 h 98h
(condition:After receiving 30 days under 20±2℃)
Acceptance Standard:
1)Each batch take nine cells for discharge test;
2)Average discharge time must be equal to or greater than the Min average discharge time. If the
Ultra Max Batteries, Watkins House Pegamoid Rd., Montagu Industrial Estate, London N18 2NG Tel: 020 8803 8899 F: 020 8803 8939 E: [email protected] W: www.ultramaxbatteries.com
WATUMX30-TEC-FEN-F15
batteries number which less than 90% of the discharge time are more than one, judge as qualified.
3)If the above results are not qualified, test again please.
8. Safety Performance
Items Condition Time Limit Demand Standard
Short Test TEM 20±2℃ 24H No Explosion N=9,Ac=0;Re=1
9. Mark
The bottom of battery shell has the following content:
1) Battery Type:LR44
2) Manufacturer:FB
3) Polarity sign: “+”
4) Battery name:BUTTON CELL
10. Notes
1) Please don’t charge the battery; it may cause leakage and damaging the charging equipment.
2) Please install batteries exactly
3) Don’t short circuit, heat the battery.
4) Don’t disassemble the battery; the internal electrolyte will corrupt the skin
5) Don’t use new electricity and have used batteries at the same time
6) Pease take the drained batteries out from appliances, avoiding leakage resulted from discharge.
7) The battery should keep away from children, beware of swallowing.
8) In order to use and protect appliances better, wipes cover face with alcohol before taking in
appliances.
11. Storage Period
1) Storing for one year In normal and reasonable environment(20±2℃,55±20%)
2) Battery capacity can be kept more than 90% in one year storage period
12. Discharge Curve (Testing temperature :20±2℃)
1) Discharge method: Discharge 24 hours per day under 6.8kΩ(schedule 1)
2) Discharge method: Discharge 24 hours per day under 1kΩ(schedule 2)
13. Battery Shape Dimension Drawing(Appended drawings )
14. Battery Chart (Appended drawings)
Ultra Max Batteries, Watkins House Pegamoid Rd., Montagu Industrial Estate, London N18 2NG Tel: 020 8803 8899 F: 020 8803 8939 E: [email protected] W: www.ultramaxbatteries.com
WATUMX30-TEC-FEN-F15
schedule 1 Discharge Characteristics LR1130 under 6.8kΩ
schedule 2 Discharge Characteristics LR1130 under 1000Ω