carloif p&c duct type db p&c duct type db- · 48808-020 48810-020 68811-020 68812-020...

2
P&C @ Duct - Type DB Carloif P&C Duct Type DB Carlon* nonmetallic P&C® Duct Type EB is manufactured from Carlon's exclusive high mod- ulus C-600 compound, developed especially for power and communica- tions applications, and is designed for use in direct burial or concrete encased installations. Type DB is rated for 90°C Cable. Trenching: Trench should be graded true and free from stones and soft spots. Backfill should also be free of stones and be firmly tamped around the sides of the con- duit, to develop maximum supporting strength. Tamping on top of the conduit is not recommended. Backfill: In rocky soil where it is impossible to have an even trench bottom, a selected backfill should be put in before laying the conduit. Selected backfill (not tamped) at least 6" over the top of the conduit is recommended. After final backfill is placed, tamping may be used to finish the grade. The method of direct burial varies with soil condition, load conditions, and engineering prefer- ences. A common practice is to lay one tier at a time, backfill, and repeat with the desired spacing of ducts being made as ducts are layered. Many companies have used the heavier wall Type DB-120 in a duct-to-duct formation. Where limited loads occur, this type of installation has proven satisfactory. P&C S Duct Type DB- Meets NEMA Standard TC-6 & 8 DB-60/ASTMF-512 Norn. Size 2 3 4 5 6 Part Number 48811-020 48813-020 48815-020 48816-020 48817-020 Std. Crate Qty. 2,800 2,000 1,140 760 520 Approx. Wt. per 100ft. 38 81 133 202 288 O.D. 2.375 3.500 4.500 5.563 6.625 *Min. Wall .060 .092 .121 .152 .182 Std. Crate Wt. (Ibs.) 1056 1612 1512 1538 1498 Broken Crate price per Hu. (ft.) S37.63 $131.81 $214.57 $329.59 $467.58 Full Crate price per Hu. (ft.) 532.72 $114.62 $186.58 $286.60 $406.59 *Min. wall thickness relates to 500,000 modulus Note: One belled end per 20' length P&C S Duct Type DB-120 Heavy Wall Meets NEMA Standard TC-6 & 8 DB-120/ASTMF-512 Norn. Size 1 11/2 2 2V2 3 4 5 6 Part Number 48808-020 48810-020 68811-020 68812-020 68813-020 68815-020 68816-020 68817-020 Std. Crate Qty. 8,000 4,500 2,800 2,040 2,000 1,140 760 520 Approx. Wt. per 100ft. 18 28 47 68 99 165 251 356 O.D. 1.315 1.900 2.375 2.875 3.500 4.500 5.563 6.625 *Min. Wall .060 .060 .077 .100 .118 .154 .191 .227 Std. Crate Wt. (Ibs.) 1416 1251 1313 1381 1984 1876 1905 1851 Broken Crate price per Hu. (ft.) $39.24 $57.39 $82.56 $411.08 $164.77 $268.40 $411.08 $508.32 Full Crate price per Hu. (ft.) $34.12 $49.90 $71.79 $357.46 $143.28 $233.39 $357.46 $442.02 *Min. wall thickness relates to 500,000 modulus Note: One belled end per 20' length Made in the U.S.A. 800-3-CARLON (322-7566) 171

Upload: others

Post on 20-Jul-2020

28 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Carloif P&C Duct Type DB P&C Duct Type DB- · 48808-020 48810-020 68811-020 68812-020 68813-020 68815-020 68816-020 68817-020 Std. Crate Qty. 8,000 4,500 2,800 2,040 2,000 1,140 760

P&C@ Duct - Type DB

Carloif P&C DuctType DBCarlon* nonmetallic P&C® Duct Type EBis manufactured from Carlon's exclusive high mod-ulus C-600 compound,developed especially for power and communica-tions applications, and is designed for use in directburial or concrete encased installations. Type DB israted for 90°C Cable.

Trenching:Trench should be graded true and free from stonesand soft spots. Backfill should also be free of stonesand be firmly tamped around the sides of the con-duit, to develop maximum supporting strength.Tamping on top of the conduit is not recommended.

Backfill:In rocky soil where it is impossible to have an eventrench bottom, a selected backfill should be put inbefore laying the conduit. Selected backfill (nottamped) at least 6" over the top of the conduit isrecommended. After final backfill is placed,tamping may be used to finish the grade.The method of direct burial varies with soilcondition, load conditions, and engineering prefer-ences. A common practice is to lay one tier at atime, backfill, and repeat with the desired spacingof ducts being made as ducts are layered.Many companies have used the heavier wall TypeDB-120 in a duct-to-duct formation. Where limitedloads occur, this type of installation has provensatisfactory.

P&CS Duct Type DB-Meets NEMA Standard TC-6 & 8

DB-60/ASTMF-512

Norn.Size

2

3

4

5

6

PartNumber

48811-020

48813-020

48815-020

48816-020

48817-020

Std.CrateQty.

2,800

2,000

1 ,140

760

520

Approx.Wt.per

100ft.38

81

133

202

288

O.D.2.375

3.500

4.500

5.563

6.625

*Min.Wall.060

.092

.121

.152

.182

Std.CrateWt.(Ibs.)1056

1 6 1 2

1 5 1 2

1538

1498

BrokenCrate

price perHu. (ft.)S37.63

$ 1 3 1 . 8 1

$214.57

$329.59

$467.58

FullCrate

price perHu. (ft.)532.72

$114 .62

$186.58

$286.60

$406.59

*Min. wall thickness relates to 500,000 modulusNote: One belled end per 20' length

P&CS Duct Type DB-120 Heavy WallMeets NEMA Standard TC-6 & 8

DB-120/ASTMF-512

Norn.Size

1

1 1 / 2

2

2V2

3

4

5

6

PartNumber

48808-020

48810-020

68811-020

68812-020

68813-020

68815-020

68816-020

68817-020

Std.CrateQty.

8,000

4,500

2,800

2,040

2,000

1 , 1 4 0

760

520

Approx.Wt.per

100ft.18

28

47

68

99

165

251

356

O.D.

1.315

1.900

2.375

2.875

3.500

4.500

5.563

6.625

*Min.Wall.060

.060

.077

.100

. 1 1 8

.154

.191

.227

Std.CrateWt.

(Ibs.)1 4 1 6

1251

1 3 1 3

1381

1984

1876

1905

1851

BrokenCrate

price perHu. (ft.)$39.24

$57.39

$82.56

$411.08

$164.77

$268.40

$411.08

$508.32

FullCrate

price perHu. (ft.)$34.12

$49.90

$71.79

$357.46

$143.28

$233.39

$357.46

$442.02

*Min. wall thickness relates to 500,000 modulusNote: One belled end per 20' length

Made in the U.S.A.800-3-CARLON (322-7566) 171

Page 2: Carloif P&C Duct Type DB P&C Duct Type DB- · 48808-020 48810-020 68811-020 68812-020 68813-020 68815-020 68816-020 68817-020 Std. Crate Qty. 8,000 4,500 2,800 2,040 2,000 1,140 760

P&C® Duct

P&C® DuctCarlon® PVC P&C® Duct and fittings are designed andformulated specifically for concrete encased and direct burialapplications of power utility primaries, secondaries, streetlighting and distribution systems. Carlon P&C® Duct complieswith NEMA Standard TC-6 & 8, and ASTM F-512 forutility duct. Both EB and DB duct are rated for use with 90°Cconductors.

Carlon® Telephone Duct complies with NEMA TC-10. BellcoreCAO 8546, GT8343, and other applicable telephone standards.

Advantages:• Manufactured for high modulus C-250 compound• High impact strength• Excellent structural strength• Superior load bearing• Multiple duct banks can be pre-assembled and lowered

into trench• No special cutting or tapering devices required• Provides easy bending around obstructions minimizing the

need for special angle couplings and sweeps• Superior aging and weathering characteristics

Features:• Heat resistant• Fire resistant• Conforms to NEMA Standard TC-6 & 8 and ASTM Standard

F-512 for utility duct*• Carlon P&C® Duct Type EB-20 is ETL Listed• Low coefficient of expansion• Continuous rigid control• Smooth inner wall and smooth transition between joints

Engineering Features:Chemical Inertness resists water absorption and is totallyimmune to galvanic or electrolytic attacks.

Solvent Cemented Joints provide leakproof duct runstested at 25 psi. This type of joint eliminates the need forcostly mechanical rodding procedure. Carlon P&C® Ductcan be rodded pneumatically.

*P&C Duct only

Made in the U.S.A.800-3-CARLON (322-7566) 169