temperature measurements at ac modules part 3 · 2016-12-19 · [ 2 ] all measurements have been...

4
competence in light www.euro-lighting-gmbh.de TEMPERATURE MEASUREMENTS AT AC MODULES Part 3

Upload: others

Post on 17-Mar-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TEMPERATURE MEASUREMENTS AT AC MODULES Part 3 · 2016-12-19 · [ 2 ] All measurements have been made with the same heat sink at an ambient temperature of 20° C. We can not recommend

competence in light

www.euro-lighting-gmbh.de

TEMPERATURE MEASUREMENTS AT AC MODULES Part 3

Page 2: TEMPERATURE MEASUREMENTS AT AC MODULES Part 3 · 2016-12-19 · [ 2 ] All measurements have been made with the same heat sink at an ambient temperature of 20° C. We can not recommend

[ 2 ]

All measurements have been made with the same heat sink at an ambient temperature of 20° C. We can not recommend a specific measuring point (TC). All measurements were taken after twenty mi-nutes working time of the LED. In our catalogue AC technology part II we recommend heat sinks of the company Fischer Electronik. But of course any other competitor’s product with the same specification is also suitable. The measurements have been made with the thermal camera by manufacturer FLIR-I3

Alle Messungen wurden mit dem gleichen Kühlkörper bei einer Raumtemperatur von 20°C durchgeführt. Einen speziellen Mess-punkt können wir nicht empfehlen. Die Messwerte wurden nach 20 Minuten Einbrennzeit erstellt. In unserem Katalog AC Techno-logie – Teil 2 empfehlen wir Modelle der Firma Fischer Elektronik. Selbstverständlich sind Wettbewerbsprodukte mit gleicher Kühlleis-tung ebenso geeignet. Die Messungen wurden mit einer Wärmelicht- kamera; Fabrikat FLIER-I3 erstellt.

Please note: the temperature at the LED chip and/or PCB will be influenced by the size and coo-ling power of the heat sink and/or the thermal conducting foil or the thermal heat glue or the thermal conducting paste

Bitte beachten Sie: Die Tempe-raturen am LED Chip und / oder Leiterplatte werden beeinflusst von der Größe / Kühlleistung des Kühlkörpers, der Wärmeleitfolie, des Wärmeleitklebers oder der Wärmeleitpaste.

Temperaturmessungen an euroLighting AC Modulen der Serie DMXXX

Temperature measurements at euroLighting modules of series DM XXX

DM3301-0522-02 5 W

DM3001-0322-02 3 W

DM5001-1322-02 13 W

DM3001-0322-02 3 W

DM3301-0522-02 5 W

DM3002-0922-02 9 WDM3002-0922-02 9 W

DM5001-1322-02 13 W

Alle technische Änderungen und Irrtümer vorbehalten!

All technical changes and mistakes reserved!

Page 3: TEMPERATURE MEASUREMENTS AT AC MODULES Part 3 · 2016-12-19 · [ 2 ] All measurements have been made with the same heat sink at an ambient temperature of 20° C. We can not recommend

[ 3 ]

Temperaturmessungen an euroLighting AC Modulen der Serie DMXXX

Temperature measurements at euroLighting modules of series DM XXX

DM 19-1423-01 14 W

MAO-4023-WW-01 40 W

DM 19-1423-01 14 W

MAO-4023-WW-01 40 W

DM7001-1722-02 17 W DM7001-1722-02 17 W

MAO-1322-WW-01 13 W MAO-1322-WW-01 13 W

DM5402-4022-02 40 W DM5403-3022-02 30 WDM5402-4022-02 40 W DM5403-3022-02 30 W

DM5401-1522-02 15 W DM5402-4022-02 40 WDM5401-1522-02 15 W DM5402-4022-02 40 W

Page 4: TEMPERATURE MEASUREMENTS AT AC MODULES Part 3 · 2016-12-19 · [ 2 ] All measurements have been made with the same heat sink at an ambient temperature of 20° C. We can not recommend

[ 4 ] 10/2

015euroLighting GmbH · Hauptstraße 56 · 72202 Nagold (Germany) · T +49 (0)74 52 60 07-16

F +49 (0)74 52 60 07-8966 · [email protected] · www.eurolighting-gmbh.eu