Museum of Science
Wind Turbine Lab
Project History and
Three-Year Performance Report
Boston, MA
![Page 2: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/2.jpg)
Why are Wind Turbines
on the Museum of Science Roof?
• Wind energy was one option explored as part of our Green Initiative,
which includes conservation, recycling, and other renewable energy
sources.
• Site, wind and structural assessment showed it was impractical to
scale wind turbines for Museum’s electrical load (9GWh/year)
– No land to install turbines, big or small. Roof is only option here.
• Little data on small-scale wind turbines are available from the built
environment
– “Built environment” includes turbines within influence of human
construction, not just on rooftops or building-integrated
![Page 3: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/3.jpg)
Goals of the MOS Wind Turbine Lab
• Testing a variety of commercially available small-scale wind turbines roof-mounted in our urban environment
• Serving as a community resource for both professionals and the general public
– A lesson in critical thinking about energy technology
– A practical demonstration and laboratory; experience; data
• An experiential part of a new Museum exhibit
• A landmark for Boston, Cambridge, New England
• A statement about the importance of renewable energy
And it also generates clean energy…
![Page 4: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/4.jpg)
Three-Year Summary 2010 through 2012
• The wind turbines average 4,229 kWh
clean electricity per year. – 15.6 kW installed, grid-tied
– 55% of average MA home annual electricity
– Museum requires > 1,000 times MA house
– 12.70 MWhr total
– Avoid over 5,100 pounds of carbon dioxide each year
• No issues with noise, vibration, ice throw, flicker, bats, other environment problems; just two bird strikes in 5-year lab history. Our neighbors like them, too.
• Not cost effective at this site – Roof installation costs were high; Complex project
– The Museum does not have a good wind regime
• Average Wind Speeds ~ 3 m/s; Recommended average 5 m/s
![Page 5: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/5.jpg)
• Project Planning
• Data Analysis
• Turbine Performance
• Lessons Learned
![Page 6: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/6.jpg)
Complex Site
PUBLIC
SAFETY
STRUCTURE
![Page 7: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/7.jpg)
But wait, there’s more!
DCR Land
Wetland
FAA / hospital / military flyway Historic District
(MA, Boston & Cambridge)
Birds? Bats?
Endangered species?
Neighbors
![Page 8: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/8.jpg)
Museum Wind Study
• Multiple locations for measurement
– Parapets
– Tower
• 3-month study correlated local data to Logan to estimate local
annual pattern
• Winds recorded for another 9 months
• Moved anemometer 1 to future Proven location
• Full report available at mos.org/WindTurbineLab
![Page 9: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/9.jpg)
Turbine Criteria
• Commercially available, residential-scale
• Size & weight appropriate for roof installation
• Responsive in our wind regime
• Within budget
• Variety of designs
– Downwind, upwind, architectural, vertical
• Manufacturer willing to accept the challenge
![Page 10: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/10.jpg)
Windspire Energy
Windspire 1.2kW @11m/s 10 m tall
Cascade Engineering
Swift 1kW @11m/s 2.1 m diameter
Southwest Windpower
Skystream 3.7 2.4kW @13m/s 3.7 m diameter
Proven Energy
Proven 6 6kW @12m/s 5.5 m diameter
AeroVironment
AVX1000 5 x 1kW @13m/s 1.8 m diameter
The Turbines
![Page 11: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/11.jpg)
The Exhibit: Catching the Wind
![Page 12: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/12.jpg)
• Project Planning
• Data Analysis
• Turbine Performance
• Lessons Learned
![Page 13: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/13.jpg)
Data Collection - Power
![Page 14: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/14.jpg)
Data Collection - Wind
![Page 15: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/15.jpg)
MOS Wind Turbine Lab
Data Analysis
• Scatter-plot power vs. wind data compared to
published power curves
• Energy and wind distribution charts
• Comparison metric is Energy / Swept Area
• Ad-hoc analyses
![Page 16: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/16.jpg)
• The Museum samples data every 2-3
seconds, after inverters, transformer.
– Wind Direction
– Power & Energy for each turbine
– Wind Speed for each turbine’s
anemometer
• Data aggregated into 10-minute intervals, includes wind speed and power
averages, min, max, std dev.
• We create scatter plots of 10-minute average power vs. 10-minute average
wind speed; compare to manufacturer’s graphs.
Understanding Power Curves -
MOS Data
![Page 17: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/17.jpg)
Understanding Power Curves -
Rated Power, Rated Speed
Ve
rtic
al a
xis
is
kW
Power Wind Speed
AVX1000 1 kW @ 13m/s
Proven 6 6 kW @ 12m/s
Skystream 3.7 2.4 kW @ 13m/s
Swift 1kW @ 11m/s
Windspire Standard
1.2 kW @ 11m/s
Windspire Extreme Wind
1.2 kW @ 13m/s
• Power Curves are graphs that plot the power a turbine generates at different
wind speeds. Defines expected performance, but not energy in local wind
regime.
• Wind Speed for “Rated Power” is not yet standardized across market,
complicating comparisons. • Example: Note difference below
between power at 12 m/s and 11 m/s.
![Page 18: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/18.jpg)
Understanding Energy
• Power is proportional to wind speed cubed and swept area: ½ρAV3
– “Rated Power” tells you about size of generator and rotor, not how much energy you can expect.
• Energy = Power * Time – Energy depends most strongly on wind speed and duration
• How fast, how long, how often
– Energy is what the end user cares about
• Wind at MOS rarely reaches the speeds at which our turbines are rated (11-13m/s)
– Beaufort Wind Scale Number 6: “Strong Breeze”
• 25 – 31 mph (11–14 m/s)
• Large branches move; river is choppy; umbrella use is difficult
– Less than 1% of wind here over 20 mph, likely typical of populated areas
• MOS turbines do produce over 4.2MWh per year – MOS WTL mean wind speeds: 6.2 – 8.3 mph (2.8 – 3.7 m/s)
– Recommended average wind speed 11 mph (5 m/s)
![Page 19: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/19.jpg)
![Page 20: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/20.jpg)
“High wind” distribution
(dark blue, right)
better correlates with
energy generation
(above)
than using average
wind speeds (below).
![Page 21: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/21.jpg)
Wind Direction
![Page 22: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/22.jpg)
![Page 23: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/23.jpg)
• Project Planning
• Data Analysis
• Turbine Performance
• Lessons Learned
![Page 24: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/24.jpg)
Skystream 3.7
Horizontal axis, Downwind ; Passive yaw
3.7-meter rotor; 10-meter tower
Closest to “plug and play” for 3.5 years. Out of service Oct 2012 thru Dec 2012.
16.5% of average MA home’s electricity.
10
hours Run plasma TV 10 hours a day.
![Page 25: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/25.jpg)
![Page 26: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/26.jpg)
Proven 6
Horizontal axis; Downwind; 5.5-meter rotor; 9-meter tower
Largest generator and rotor of the Museum turbines.
Produces the most energy but underperforms at higher winds. speeds.
Wiring adjustment August 2012
28.7% of average MA home’s electricity. 18
hours Run plasma TV 18 hours a day.
![Page 27: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/27.jpg)
Proven Power Curves
![Page 28: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/28.jpg)
![Page 29: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/29.jpg)
4
hours
AVX1000 (5 Units)
Horizontal axis; Upwind; 1.8-meter rotor.
These turbines act independently,
but we add their power together.
Hardware and inverter problems repaired;
Improved, still underperforming.
6.8% average MA home’s electricity.
Run plasma TV 4 hours a day.
![Page 30: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/30.jpg)
![Page 31: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/31.jpg)
Swift
Horizontal axis; Upwind; 2-meter rotor
The computer model picture below shows
how wind from the river slows down when
it gets to the Swift (at the small blue swirl
on the roof).
1.2% average MA home’s electricity.
Run plasma TV less than an hour a day. < 1
hour
TRC/Ansys Computational Flow Model
![Page 32: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/32.jpg)
Swift: Investigating Power Curve’s Lower Limb
N
NNE
NE
ENE
E
ESE
SE
SSE
S
SSW
SW
WSW
W
WNW
NW
NNW
Why do some high-wind records yield very low power?
- CFD model and observation indicates in SW wind Swift often
yaws without spinning.
- Can anemometer (2 inch diameter) measure high winds in
eddy that Swift (2 meter diameter) cannot utilize?
- Are effects seasonal? Directional? Vary by wind bin?
• At wind speeds over 6 m/s, 82% of the data records follow
the power curve.
• Roof drag and structural obstacles may impede Swift’s
operation, but most of the data does follow the power curve,
performing to spec.
![Page 33: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/33.jpg)
![Page 34: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/34.jpg)
Windspire Standard Model
1Jan2010 – 30Jun2011
Vertical-axis; 6-meter tall rotor
Cut-out logic reduced access
to high energy wind, but
standard model tracks power
curve well to 8 m/s.
Due to inverter issues,
Windspire shut down Jan, Feb,
most of Aug, half of Sep, end
of Dec.
Nearby chiller fan may affect
turbine or anemometer during
summer months.
![Page 35: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/35.jpg)
![Page 36: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/36.jpg)
Windspire Extreme Wind Model
Vertical-axis; 4-meter tall rotor.
1.6% average MA home’s electricity.
Run plasma TV one hour a day.
1
hour
Windspire Extreme Wind
model replaced Standard
model July 11, 2011 - Designed to cut-out at higher
wind speed (40mph) and
recover much faster.
- Reduction in swept area shifts
power curve to the right.
- Tracks power curve well,
except:
Depressed power curve reliably
occurs during hot weather months.
Specific causes unclear.
![Page 37: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/37.jpg)
![Page 38: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/38.jpg)
Windspire Power Curve Comparison
Standard and Extreme Wind Models
![Page 39: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/39.jpg)
Swift
Skystream 3.7
AVX1000
How to Compare? Energy / Swept Area
Proven 6
Windspire
SWEPT
AREA
![Page 40: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/40.jpg)
Comparing Different Wind Turbines (2010 – 2012 data, except where noted)
TURBINE Annual
Energy/
Swept
Area
(kWh/m2)
Avg
Wind
Speed
(m/s)
Rated
Power
(kW)
Energy/Year
(kWh) MA Home
(EIA avg 2010,2011)
Notes
Skystream
118 2.9 2.4 1278 16.5% Performing as expected here.
Out of service Oct2012 thru
Dec2012.
Proven 93 2.8 6.0 2218 28.7% Generally performs well; Power
plateaus early.
Improved after rewiring
Aug2012.
AVX1000 (5 units)
40 3.7 5.0 525 6.8% Highly directional. Improved
after 2010 repairs, but still
underperforming.
Swift 25 2.8 1.0 90 1.2% Some issues with siting; data
tracks power curve most of the
time.
Extreme Wind
Windspire (11Jul2011-31Dec2012)
25 2.9 1.2 123 1.6% Replaced Standard model
11Jul11. Performing as
expected here. Seasonal site
issues.
Standard
Windspire (2010 only)
24 3.1 1.2 176 2.2% Out of service 4 months of 12.
Seasonal site issues. Shut
down Dec2010.
![Page 41: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/41.jpg)
Performance over Time
![Page 42: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/42.jpg)
• Project Planning
• Data Analysis
• Turbine Performance
• Lessons Learned
![Page 43: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/43.jpg)
MOS Lessons Learned
• Successful experiment! – Generates 4.2 MW-hr clean electricity, avoids 5,100 lbs carbon dioxide annually
– Attractive addition to Museum; Draws interest on renewable energy
– Have provided detailed data and project information to over 1,300 people:
industry professionals, universities, government and the general public,
plus all visitors interacting with the Catching the Wind exhibit
• Be clear on project goals. – Energy? Education? Economics?
– Seek stakeholder buy-in early and often.
• Measure wind profile as close to hub height as practical. – Understand how much energy you can expect in your wind regime.
• Installation sites needed to be a compromise here. – Building roof structure, permitting, and wind rarely converged
– Roof mounting some of these turbines expensive compared to ground installation.
![Page 44: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/44.jpg)
The Team Museum of Science
David Rabkin, Director for Current Science and Technology
Paul Ippolito, Director, Facilities
Steve Nichols, Project Manager, IIT
Marian Tomusiak, Wind Turbine Lab Analyst
Boreal Renewable Energy Development
Bob Shatten, Principal
Tom Michelman, Principal
Alex Weck, Principal
Michael Alexis, Principal
ANSYS/TRC
Valerio Viti, Sr. Fluids Specialist
Chris DesAutels, Sr. Meteorologist
Lloyd Schulman, Sr. Meteorologist
Apterra Technologies
Ted Schwartz, Principal
Nexamp, Inc.
Will Thompson, VP, Integration
Phelan Engineering
Paul Phelan, Jr., P.E.
Richard Gross, Inc.
Richard Gross, P.E.
Rubin and Rudman, LLP
Keren Schlomy, Partner
Shaw Welding Company
Rick Shaw, President/CEO
Titan Electric Corporation
John Gill, President
Renewable Energy Trust / Mass CEC
Dick Tinsman, now with Criterium Engineers
Rapheal Herz, now with Johnson Controls
Jim Christo, now with Alteris Renewables
Marybeth Campbell, now with the Massachusetts
Clean Energy Center
Christie Howe, Massachusetts Clean Energy Center
Underwriters
Kresge Foundation
Cascade Energy
Museum of Science and its supporters
And the Extended Project Team
![Page 45: Three-Year Performance Report](https://reader036.vdocument.in/reader036/viewer/2022062504/586685361a28ab31408b628f/html5/thumbnails/45.jpg)
View from Museum of Science Garage Roof
One Science Park, Boston MA August 2011
Marian Tomusiak
Wind Turbine Lab Analyst
David Rabkin
Farinon Director,
Current Science and Technology
mos.org/WindTurbineLab
mos.org/Energized
September 2014