tissat presentación enertic+cdti-2012-dic-18.v3

23
Encuentro “innovación abierta en Eficiencia Energética” (12 de diciembre de 2012)

Upload: carlos-cebrian

Post on 27-May-2015

159 views

Category:

Technology


2 download

DESCRIPTION

TISSAT's Energy Efficiency DataCenter R&D lines and results: Wallahalla certified as Tier IV (by The Uptime Insitute) and PUE = 1.15

TRANSCRIPT

Page 1: Tissat presentación enerTIC+CDTI-2012-dic-18.v3

Encuentro “innovación abierta en

Eficiencia Energética”(12 de diciembre de 2012)

Page 2: Tissat presentación enerTIC+CDTI-2012-dic-18.v3

TISSAT, an Innovative Successful Spanish Company

1

Successful Spanish Company

Page 3: Tissat presentación enerTIC+CDTI-2012-dic-18.v3

Basic Enterprise Data

Main data:

• Founded in Valencia (Spain) in 1990

• Currently 232 persons: 55.6% man, 44.4% women (about 280 accounting outsourced staff)

• 2011 billing: 15.3 M€

• But NO SME

• Branches in:

­ Bilbao,

­ Castellón,­ Castellón,

­ Madrid,

­ Murcia,

­ Valencia (3),

­ and Vitoria.

Page 4: Tissat presentación enerTIC+CDTI-2012-dic-18.v3

Business

5 main Business Areas:

1. Data Centre (DC) value added services:

­ from collocation to Cloud Service Provider, trough DRP, managed services, and so on.

­ 3 “federated” DC: one of them (Walhalla) Tier IV certified by The Uptime Institute, with

PUE = 1.15, and following the EU DataCentres Code of Conduct.

2. EU­112 (USA­911) and Emergency Operation Centre: (112­Valencian Community, 112­

Murcia Region, ...).

3. ITC focused ContactCentre & CallCentre (both HelpDesk services and operations).

4. Web 2.0 based services (social media marketing, social network based applications, …).

5. Ad­hoc software development (built on open­source software), mainly mission­critical 5. Ad­hoc software development (built on open­source software), mainly mission­critical

focused.

Standards certifications:

ISO 20.000, ISO 27.001, ISO 50.001, ISO 14.001, ISO 9.001, UNE 166.002, CMMI L2.

Page 5: Tissat presentación enerTIC+CDTI-2012-dic-18.v3

R&D Activities

2

Page 6: Tissat presentación enerTIC+CDTI-2012-dic-18.v3

Research & Development (1)

R&D investments:

• Last 5 years average > 7 %, growing and ranging 5% ­ 10% (referred to Tissat annual billing)

Main Current R&D Areas of Interest:

• Green DC & Green IT

• Cloud Computing

• Predictive IT Operation

• Intelligent IT Automation

• Public Emergency Operation Centre

• Big Data

• New Social Networking based services

• e­Health value added services

• Mobility and Augmented Reality

Page 7: Tissat presentación enerTIC+CDTI-2012-dic-18.v3

Green DCR&D Rationale

3

R&D Rationale

Page 8: Tissat presentación enerTIC+CDTI-2012-dic-18.v3

DataCenters “Federation”

DC “P.T.”Tier III+Paterna

DC “Walhalla”Tier IV

Castellón

“Federation”: a set of trusted and high speed linked DC, usually owned by the same entity.

Paterna

DC “Brasil”Tier IIIMadrid

Castellón

WAN

f.o.

f.o.

f.o.

Page 9: Tissat presentación enerTIC+CDTI-2012-dic-18.v3

Goal: Competitiveness Enhancing

1.- COST REDUCTION BY OPERATIONAL EFFICIENCY:

• Great savings by energy waste reduction

• PUE = 1,15 means a 15% reduction in operating costs.

• => Whole environmental footprint reduction (not only energy, but water use, and other impacts

based in the life cycle sustainability assessment) i.e. Greenhouse Gas (GHG) Emission reduction.

• => Public Laws and Government Regulations

• => Corporative Social Responsibility.

• Great savings in maintenance costs

• Optimization through the homogenization of equipment and cloud mode systems, besides the • Optimization through the homogenization of equipment and cloud mode systems, besides the

knowledge transfer to support Level 1, represent a savings of 20% in operating costs.

• Services in industrialized mode

• Maximizing operations through ITIL + LEAN MANAGEMENT, costs per ticket means 10%

reduction in total operating costs.

TOTAL REDUCTION 45 %

2.- Innovative and Differentiating NEW SERVICES:

• Tier IV

• Cloud Services

Page 10: Tissat presentación enerTIC+CDTI-2012-dic-18.v3

6 Actuation Axis

1.- COST REDUCTION BY OPERATIONAL EFFICIENCY:

• Great savings by energy waste reduction

• PUE = 1,15 means a 15% reduction in operating costs.

• => Whole environmental footprint reduction (not only energy, but water use, and other impacts

based in the life cycle sustainability assessment) i.e. Greenhouse Gas (GHG) Emission reduction.

• => Public Laws and Government Regulations

• => Corporative Social Responsibility.

• Great savings in maintenance costs

• Optimization through the homogenization of equipment and cloud mode systems, besides the • Optimization through the homogenization of equipment and cloud mode systems, besides the

knowledge transfer to support Level 1, represent a savings of 20% in operating costs.

• Services in industrialized mode

• Maximizing operations through ITIL + LEAN MANAGEMENT, costs per ticket means 10%

reduction in total operating costs.

TOTAL REDUCTION 45 %

2.- Innovative and Differentiating NEW SERVICES:

• Tier IV

• Cloud Services

Page 11: Tissat presentación enerTIC+CDTI-2012-dic-18.v3

DC Design: WALHALLA

• PUE = 1.15

• Designed for Cloud Computing Services.

• Auto­generation.

• Walhalla has been certified as TIER IV by the

Uptime Institute to give services to external

clients.

• Auto­generation.

• Trigeneration energy production by gas engines in the

first phase (and by fuel cell in the second phase).

• Free­cooling.

• Heat confinement.

• Residual and unused energy reuse

• Overhead Distribution of power, data and climate.

• Integration between ITC management systems and energy infrastructure.

Page 12: Tissat presentación enerTIC+CDTI-2012-dic-18.v3

Infografía

Walhalla. Vista General

Page 13: Tissat presentación enerTIC+CDTI-2012-dic-18.v3

Walhalla. Edificio TIC y Generación

Page 14: Tissat presentación enerTIC+CDTI-2012-dic-18.v3

Walhalla. Salas Técnicas

Page 15: Tissat presentación enerTIC+CDTI-2012-dic-18.v3

DC Operation PROCESSES (& METRICS)

1.- ENERGETIC EFFICIENCY:

• EU Code of Conduct for Data Centres

• ISO 50.001 (UNE 16.001).

• ISO 14.001

• PILOTO CON AENOR (MARCA CEE CPD)

• NEW Greenhouse Gas (GHG) Emission METRICS:

• PUE (Power Usage Effectiveness)• PUE (Power Usage Effectiveness)

• WUE (Water Usage Effectiveness)

• CUE (Carbon Usage Effectiveness)

• GEC (Green Energy Coefficient)

• ERF (Energy Reuse Factor)

• Other points of view: Life Cycle Sustainability Assessment

2.- OPERATIONAL EFFICIENCY:

• ISO 20.000

• ISO 27.001

• ISO 9.001

Page 16: Tissat presentación enerTIC+CDTI-2012-dic-18.v3

ICM

(IT Management of Cloud Environment)

NAGIOS OTHERSTIVOLISNMP

Manag.

SCADA

Manag.

Energy

Manag.

IMS

(Installations Management

Subsystem)

En

gin

es

Ge

ne

rato

rs

Air

Co

nd

itio

ne

r

Vig

ila

nce

Ro

ute

rs

Sw

itch

es

DCIM (Data Centre Infrastructures Management)

En

gin

es

Ge

ne

rato

rs

UP

S

Air

Co

nd

itio

ne

r

Oth

ers

Fan

s

Vig

ila

nce

Se

rve

rs

Sto

rag

e

Ro

ute

rs

Sw

itch

es

Oth

ers

GARTNER: DCIM integrates the management of both information technology (IT systems)

and facility and installations (i.e. no IT equipment) of a DC in order to centralize monitoring,

management and intelligent capacity planning of a data center's critical systems

i.e. solution that operates DC in holistic way orchestrating IT operations with Installation

operations under a common global DC Management that control both IT systems and energy

and other Installations systems, and synchronize them focusing on both efficiency

improvement (both energy and operations).

Page 17: Tissat presentación enerTIC+CDTI-2012-dic-18.v3

IT Management

IT Automation

DataCenter Automation

DataCenter Services Automation

DCIM as Operational Intelligence Aggregator

Servers

Manag.

Network

Manag.

Storage

Manag.

Physical Resources ManagementVirtual Resources

Management

IT Management

Installations

Management

DCIM (Data Centre Infrastructure Management)

Page 18: Tissat presentación enerTIC+CDTI-2012-dic-18.v3

IT Automation

DataCenter Automation

Cloud Computing Services Automation

DataCenter Services Automation

Multi-DCIM: Extending Efficiency to a Multi DC FEDERATION

Multi DCIM (MultiDataCenter + MultiProvider)

Servers

Manag.

Network

Manag.

Storage

Manag.

Physical Resources ManagementVirtual Resources

Management

IT Management

Installations

Management

DCIM (Data Centre Infrastructure Management)

Page 19: Tissat presentación enerTIC+CDTI-2012-dic-18.v3

CLOUD COMPUTING: Efficiencies, but Challenges & Risks

Page 20: Tissat presentación enerTIC+CDTI-2012-dic-18.v3

Green DC related R&D Projects

4

ProjectsR&D

Page 21: Tissat presentación enerTIC+CDTI-2012-dic-18.v3

Current EU projects:

• EU-FP7: CloudSpaces (2012)

• EU­LLP: IT­Clex (2010)

• Collaborator in Climatic KIC (one of 3 Knowledge and Innovation Communities by EIT) 2011

National Related Current R&D projects:

• PredictiveI2TM (2009)

Research & Development (2)

• RealCloud (2011)

• GreenDC (2010 )

• CPD verde (2011)

• other http://www.tissat.es/en/rdi/projects:

– FASyS, CERI, etc.

So far R&D publicized articles:

• About 20 (http://www.tissat.es/en/rdi/publications)

Page 22: Tissat presentación enerTIC+CDTI-2012-dic-18.v3

Research & Development (3)

Partner Country

City of Oulu FIN

Metsolan Kotihoito Oy FIN

Prowellness FIN

Pending EU projects:

• FP7­SMARTCITIES­2013: SMART DC FED “A SmartGrid & DCIM based Approach for a

Sustainable DC Federation” (addressing: the Objective ICT­2013.6.2 Data Centres in an

energy­efficient and environmentally friendly Internet). Participant organisation name Country

1 TISSAT (Coordinator) Spain 2 Universitat Jaume I Spain 3 Eurecom France 4 ENEA Italy 5 Università degli Studi di Palermo Italy 6 Posta Slovenije Slovenia 7 Gama System Slovenia

Seniortek Oy FIN

Siperia Systems Oy FIN

VTT Technical Research Centre of Finland FIN

Development Laboratories (DevLab) NLD

Eindhoven University of Technology NLD

Altfactor ROU

Siveco Romania S.A. ROU

ABADA ESP

BALMART SL ESP

Research Foundation of Hospital La Fe ESP

TSB SA ESP

TISSAT S.A. ESP

Universidad Politécnica de Valencia (UPV) ESP

University of Malaga ESP

Bor Yazilim San. Tic. Ltd. Sti. TUR

Likya Yazlm Ltd. ti. TUR

NATEK TUR

• ITEA2: PRO-HEAL “Automated Protection and Healing Software

Solutions”.

• EUROSTARS: INPLANT “Industrial Plant Abstraction and Wireless

and Cloud Computing based Intelligent Monitoring and Control”.Partner Country

Mondragón Sistemas de Información, S.Coop ESP

TISSAT, S.A. ESP

IFAK System GmbH GER

IKERLAN (subcontracted) ESP

7 Gama System Slovenia 8 DNV KEMA Netherlands

Page 23: Tissat presentación enerTIC+CDTI-2012-dic-18.v3

Carlos Cebrián

Director I+D+i

e­mail: [email protected]

Skype: c.cebrianSkype: c.cebrian

Twitter: cjcebrian

Blog I+D: TISSAT.wordpress.com

Web: www.tissat.es