TomoDirect Discrete-angle delivery with continuous couch motion Applying platform power for patient throughput With the TomoDirect mode, the user can simply: apply up to 12 discrete angles to single or multiple targets for optimal coverage; define a modulation level, or opt for tissue-compensated 3D conformal delivery; complete treatment planning quickly with all the power of the TomoTherapy computing platform applied to a small number of beams; and deliver all beams for each target, sequentially, with a single turn of the operator console key. As with the TomoHelical mode, the treatment couch passes through the bore of the system during a TomoDirect delivery. This makes it possible for users to treat target volumes up to 135 cm in length for typical patient set-up, with no need to reposition the patient and no field junctioning required. TomoDirect is a non-rotational treatment option for the TomoTherapy ® platform. It was developed as a clinical complement to the TomoHelical delivery mode, and allows users to plan and treat routine cases with greater efficiency, while maintaining the quality of TomoTherapy’s unique beamlet-based delivery. COUCH MOTION Two tangential fan-beams used to achieve dose distribution shown above

Upload: others

Post on 07-Oct-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TomoDirect - Tomotherapy · States and other countries: TomoTherapy, Tomo, TomoDirect, TomoHelical, TomoHD, TomoMobile, TQA, Hi·Art, CTrue, and the TomoTherapy logo. M-GEN-019-0211

TomoDirect™ Discrete-angle delivery with

continuous couch motion

Applying platform power for patient throughputWith the TomoDirect mode, the user can simply:

• apply up to 12 discrete angles to single or multiple targets for optimal coverage;

• define a modulation level, or opt for tissue-compensated 3D conformal delivery;

• complete treatment planning quickly with all the power of the TomoTherapy computing platform applied to a small number of beams; and

• deliver all beams for each target, sequentially, with a single turn of the operator console key.

As with the TomoHelical mode, the treatment couch passes through the bore of the system during a TomoDirect delivery. This makes it possible for users to treat target volumes up to 135 cm in length for typical patient set-up, with no need to reposition the patient and no field junctioning required.

TomoDirect™ is a non-rotational treatment option

for the TomoTherapy® platform. It was developed

as a clinical complement to the TomoHelical™ delivery

mode, and allows users to plan and treat routine cases

with greater efficiency, while maintaining the quality of

TomoTherapy’s unique beamlet-based delivery.

COUCH MOTION

Two tangential fan-beams used to achieve dose

distribution shown above

Page 2: TomoDirect - Tomotherapy · States and other countries: TomoTherapy, Tomo, TomoDirect, TomoHelical, TomoHD, TomoMobile, TQA, Hi·Art, CTrue, and the TomoTherapy logo. M-GEN-019-0211

1310 Chesapeake Terrace | Sunnyvale, CA 94089 | USA | Tel: +1.408.716.4600 | Toll Free: 1.888.522.3740 | Fax: +1.408.716.4601 | Email: [email protected]

TomoDirect™ Discrete-angle delivery with continuous couch motion

A direct response to customer requests

TomoTherapy is focused on helping cancer centers deliver the highest-quality radiation therapy to every patient who walks through the door. To fulfill this mission, we continually seek the input of existing and prospective customers to tell us what they need most from our advanced radiation therapy platform. The TomoDirect delivery mode addresses a number of these critical needs.

Accuray Inc. reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication.

©2011 Accuray Incorporated. All rights reserved. The following marks as used herein in italicized or stylized text are among trademarks, service marks or registered trademarks of Accuray Incorporated in the United States and other countries: TomoTherapy, Tomo, TomoDirect, TomoHelical, TomoHD, TomoMobile, TQA, Hi·Art, CTrue, and the TomoTherapy logo. M-GEN-019-0211

TomoDirect technology facilitates breast treatments with a familiar “tangent-like” dose distribution that can be quickly planned and delivered.

Right breast tangential delivery

• Two tangential beams

• Planning time: ~ 10 minutes

• Treatment delivery time: ~ 2.5 minutes

TomoDirect technology provides innovative, yet simple planning and treatment delivery efficiencies for routine cases.

Whole brain treatment delivery

• Right and left lateral beams

• Planning time: ~ 10 minutes

• Treatment delivery time: ~ 2.2 minutes

TomoDirect technology brings gold-standard quality and workflow efficiency to fixed-gantry-angle treatments.

Three metastatic sites

• 11 treatment beams

• Planning time: ~ 10 minutes

• Treatment delivery time: ~ 10 minutes

• Automated delivery

• No shifting of the patient between sites

• No field junctioning

53.5

52

50

49

45

30

15

32.1

30

28.5

27

24

21

15

9

32.1

30

28.5

27

24

21

15

9

The TomoDirect delivery mode is included as standard on the TomoHD™ treatment system, and is available as an option on the Hi·Art® treatment system.