trane product data - r-410a split system up to 38 seer inverter … · 2020. 4. 29. · ©2016...

14
© 2016 Trane Pub. No. 22-1927-1A-EN Product Data Split System (R-410A) up to 38 SEER, Inverter System 9,000 to 24,000 BTU/Hr Single Split Indoor Unit Outdoor Unit Heat Pump 4MXW38-A 4TXK38-A 22-1927-1A-EN

Upload: others

Post on 09-Mar-2021

15 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Trane Product Data - R-410A Split System up to 38 SEER Inverter … · 2020. 4. 29. · ©2016 Trane Pub. No. 22-1927-1A-EN Product Data Split System (R-410A) up to 38 SEER, Inverter

© 2016 Trane Pub. No. 22-1927-1A-EN

Product DataSplit System (R-410A)up to 38 SEER, Inverter System 9,000 to 24,000 BTU/Hr

Single Split Indoor Unit Outdoor UnitHeat Pump 4MXW38-A 4TXK38-A

22-1927-1A-EN

Page 2: Trane Product Data - R-410A Split System up to 38 SEER Inverter … · 2020. 4. 29. · ©2016 Trane Pub. No. 22-1927-1A-EN Product Data Split System (R-410A) up to 38 SEER, Inverter

2

It's Hard to Stop a Trane.Split System (R-410A, 60Hz) up to 38 SEER, Inverter System - 9,000 to 24,000 BTU/Hr

Whatever their specific heating and cooling needs, people trust Trane to provide reliable ef-ficient solutions. Trane Ductless Systems allow you to create a comfortable indoor environment in spaces where adding ductwork might be impractical or too expensive, or not as efficient as a ductless option.

Retrofit a house that doesn't have a ducted system or where the central system is already at capacity. Bring efficient, economical comfort to new room additions. Provide spot heating and cooling that operates independently of the central system. Utilize ductless efficiency for new construction projects where ductless systems make more sense than a traditional ducted system.

Easy to install Trane Ductless Systems offer flexibility in design and provide efficiency and economy with two simple components - an outdoor unit and one or more stylish, low profile, indoor units. All built with Trane's legendary reliability and innovative thinking.

Introducing the New TRANE Ductless Family

Quiet DesignSpecially designed air vent efficiently reduces operation noise, as low as 19 dB.

Turbo Function/Fan SpeedHigh speed operation quicklyreaches desired temperature. Seven fan speeds from Quiet to Turbo maxi-mize your comfort experience.

Sleep Mode FunctionTemperature rises/falls automatically to maintain room comfort and save energy while you sleep.

Auto Clean/Triple FiltrationFan runs when unit is stopped to reduce moisture and inhibit the de-velopment of bacteria, and the triple filtration further cleans the air that you breathe.

Anti-Cold DesignTo prevent blowing cold air directlyto the room, air is pre-heated duringheating operation.

TimerOperate the unit automatically onlywhen you want by setting the timer.

Outdoor Unit

Energy EfficiencyQuickly reach the desired temperaturewithout sacrificing your electricity billswith our higher EER/COP levels.

Robust GrillePrevent damage without impactingairflow with our strong, hot-dipgalvanized steel grille.

Intelligent DefrostAuto defrosting is implemented ifnecessary. It improves the system’sheating efficiency and helps yousave power. (Standard on all heat pump models.)

Blue FinIncrease durability and ensurecontinued efficiency with our special anti-corrosion coil treatment.(Standard on all heat pump models.)

Twin RotaryDC CompressorProvides better balance andhigher efficiency.

Compressor ProtectionCompressor stops or delays opera-tion when there is mode conflict.

4MXW38 High Efficiency Indoor Unit

4TXK38 Outdoor Unit

Page 3: Trane Product Data - R-410A Split System up to 38 SEER Inverter … · 2020. 4. 29. · ©2016 Trane Pub. No. 22-1927-1A-EN Product Data Split System (R-410A) up to 38 SEER, Inverter

3

Contents

Model Nomenclature 5

Optional Equipment 6

General Data 7-10

Unit Capacities 11

Mechanical Specifications 12

Page 4: Trane Product Data - R-410A Split System up to 38 SEER Inverter … · 2020. 4. 29. · ©2016 Trane Pub. No. 22-1927-1A-EN Product Data Split System (R-410A) up to 38 SEER, Inverter

4

Refrigerant Service Digit   4 = R‐410A A, B, C, etc. = Service Digit Sequence

BrandT = Outdoor Unit Minor Design Sequence

A, B, C, etc. = Minor Design SequenceFunctional Type  X = Heat Pump Inverter Reserved for Future UseY = Cooling Only Inverter 0 = Not Currently Used

U = Ultra Low AmbientConfiguration Outdoor UnitK = Single Refrigerant Port Regional Markets Served (1:1 Systems)M =  Multiple Refrigerant Ports N = North America MarketU =  Pro Series or Number of Refrigerant Ports for  

16 SEER Multi‐Split SystemsEfficiency Tier 2 = Two Port System16 = 16  SEER  3 = Three Port System65 = 16 SEER 4 = Four Port System85 = 18 SEER 5 = Five Port System20 = up to 20 SEER Pro Series22 = up to 22 SEER Refrigerant Ports27 = up to 27 SEER 0 = Mini‐Split Systems38 = up to 38 SEER or Number of Refrigerant ports for 

up to 22 SEER Multi‐Split Systems

Nominal Capacity (Btu/h x 1,000) Electric Power Supply Characteristics09  =   9,000 Btu/h 30  = 30,000 Btu/h 1 = 208‐230/60/1 12  = 12,000 Btu/h 36  = 36,000 Btu/h18  = 18,000 Btu/h 42  = 42,000 Btu/h21  = 21,000 Btu/h 48  = 48,000 Btu/h Major Develompent Sequence 24  = 24,000 Btu/h A, B, C, etc. = Major Development Sequence

  

OUTDOOR UNIT MODEL NOMENCLATURE

A157‐8

1214

2T

3X

4K

5‐665

9A

10 111 0

12N

130

14B

12

Refrigerant Service Digit   4 = R‐410A A, B, C, etc. =  Service Digit Sequence

Unit TypeM = Indoor Unit Minor Design SequenceU = Pro Series A, B, C, etc.  = Minor Design Sequence

Functional Type Reserved for Future UseX = Heat Pump Inverter 0 = Not Currently UsedY = Cooling Only Inverter U = Ultra Low Ambient

 Configuration Indoor Unit Regional Markets Served (1:1 Systems)W = High Wall Unit    N = North America MarketD = Ceiling Concealed Unit  C = Cassette Unit Reserved for Future UseF = Floor Console Unit 0 = Not Currently UsedX = Convertible (Floor/Ceiling) MountL = Cassette Panel Cover Electric Power Supply Characteristics

1 = 208‐230/60/1 Efficiency Tier16 = 16 SEER 65 = 16 SEER Major Development Sequence 85 = 18 SEER A, B, C, etc.  = Major Development Sequence20 = up to 20 SEER Pro Series22 = up to 22 SEER27 = up to 27 SEER38 = up to 38 SEER

Nominal Capacity (Btu/h x 1,000)09 =  9,000 Btu/h 30  = 30,000 Btu/h12 = 12,000 Btu/h 36  = 36,000 Btu/h18 = 18,000 Btu/h 42  = 42,000 Btu/h  21 = 21,000 Btu/h 48  = 48,000 Btu/h24 = 24,000 Btu/h

INDOOR UNIT MODEL NOMENCLATURE

65 B9 10 11 13 14A 1 0 N 0

14

2M

3A157‐8

12X4X

5‐6

Page 5: Trane Product Data - R-410A Split System up to 38 SEER Inverter … · 2020. 4. 29. · ©2016 Trane Pub. No. 22-1927-1A-EN Product Data Split System (R-410A) up to 38 SEER, Inverter

5

Optional outdoor unit accessories 4TXK38 Model Mini-split HPNumber Description up to 38 SEERTAYREFLN560 ....................... Lineset Kit 1/4x1/2 - 25' ................................................................................................. ✔

TAYREFLN565 ....................... Lineset Kit 1/4x1/2 - 35' ................................................................................................. ✔

TAYREFLN570 ....................... Lineset Kit 1/4x1/2 - 50' ................................................................................................. ✔

TAYREFLN575 ....................... Lineset Kit 1/4x1/2 - 100' ............................................................................................... ✔

TAYREFLN155 ....................... Lineset Kit 1/4x5/8 - 25' ................................................................................................. ✔

TAYREFLN160 ....................... Lineset Kit 1/4x5/8 - 35' ................................................................................................. ✔

TAYREFLN165 ....................... Lineset Kit 1/4x5/8 - 50' ................................................................................................. ✔

TAYREFLN170 ....................... Lineset Kit 1/4x5/8 - 100' ............................................................................................... ✔

Optional indoor unit accessories 4TXW38Model Mini-split IndoorNumber Description up to 38 SEER BAYFTHW02P2A ...................Active Carbon & Catechin filter 38 SEER units .............................................................. ✔

TREMOTE2AHANDAA ..........Wireless Controller ......................................................................................................... ✔

TREWIRE1AHANDAA ...........Wired Controller ............................................................................................................ ✔

TREPROG1AHANDAA ..........Programmable Controller .............................................................................................. ✔

Optional Equipment

See the Service First Mini-Split Accessory Catalog for the complete accessory list.

Air Throw for High WallMax Horizontal Distance

Unit: ft. (m)Model Cooling Mode Heating Mode

4MXW3809

31.2 (9.5) 31.2 (9.5)4MXW3812

4MXW3818

4MXW3824

Page 6: Trane Product Data - R-410A Split System up to 38 SEER Inverter … · 2020. 4. 29. · ©2016 Trane Pub. No. 22-1927-1A-EN Product Data Split System (R-410A) up to 38 SEER, Inverter

6

General DataMODEL - Heat Pump Only

RATED Volts/PHFrequency (Hz)Rated Cooling / Heating Capacity (Btu/h):Minimum Cooling Capacity (@95°F) (Btu/h): 2Maximum Cooling Capacity (@95°F) (Btu/h): 2Minimum Heating Capacity (@47°F) (Btu/h): 2Maximum Heating Capacity (@47°F) (Btu/h): 2Maximum Heating Capacity (@17°F) (Btu/h): 2

Total Capacity (W) (High/Standard/Low):Nominal Power Input (W)Nominal Input Current (A)SEER / HSPFEER / COP (Btu/h)/W Air Flow Volume (CFM) (TURBO/MH/H//M/ML/L/QUIET)Dehumidifying Volume (pt./h)

Indoor Unit Fan Motor Speed (r/min) (TURBO/MH/H//M/ML/L/QUIET)Fan Motor RLA(A)EvaporatorPipe Diameter (inch)Rows - Fin Gap (inch)Coil length (L) x depth (D) x coil width (W) (inch)Output of Swing Motor (W)Fuse (A)Sound PRESSURE Level dB (A)(TURBO/MH/H//M/ML/L/QUIET) 1Uncrated Dimension (W/H/D) (inch)Crated Dimension of Package (L/W/H) (inch)Net Weight /Gross Weight (lbs)

Outdoor UnitCompressor TypeCompressor Oil TypeL.R.A. (A)Compressor RLA(A)Compressor Power Input(W)Throttling MethodWorking Temp Range (°F)CondenserPipe Diameter (inch)Rows - Fin Gap (inch)Coil length (L) x depth (D) x coil width (W) (inch)Fan Motor Speed (rpm) Output of Fan Motor (W)Fan Motor RLA (A)Air Flow Volume of Outdoor Unit (CFM)Fan Diameter (inch)Defrosting Method

Sound PRESSURE Level dB (A)1Uncrated Dimension (W/H/D) (inch)Crated Dimension of Package (L/W/H) (inch)Net Weight /Gross Weight (lbs)Refrigerant Charge (oz)MCAMOP

Connection PipeGas additional charge(oz/ft)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Max Height Distance (ft)Max Length Distance (ft)

1 Sound PRESSURE Level @ 3.3 ft. dB(A)2 Capacities based on fixed compressor speed AHRI validation testing

4MXW3809A10N / 4TXK3809A10NCooling Heating

208 / 230 / 160Hz

9000 90001500 -12900 -- 2300- 13600- 5600

3780 / 2610 / 450 3990 / 2610 / 690 540 590 3.0 3.1538.0 15.016.5 4.8420/380/350/320/300/240/210

1.7

4MXW3809A10N1200/1100/1030/960/890/820/750/500 1300/1200/1120/1040/960/880/800

0.09Aluminum Fin-Copper Tube

0.282.0 - 0.06

28.1 x 1.0 x 12.01.5/2.5

3.1544/40/38/36/33/31/19

39.2 x 11.9 x 8.941.7 x 18.9 x 12.7

29.8 / 36.4

4TXK3809A10NRotary

FV50S (PVE Oil)356.9

1070EEV

0 ~ 129 -22 ~ 75Aluminum Fin-Copper Tube

0.282.0 - 0.06

30.0 x 2.2 x 21.780030

0.24141017.2

Automatic Defrosting

5335.4 x 23.5 x 14.937.3 x 16.5 x 25.4

99.2 / 105.846915

2.311/41/250100

Page 7: Trane Product Data - R-410A Split System up to 38 SEER Inverter … · 2020. 4. 29. · ©2016 Trane Pub. No. 22-1927-1A-EN Product Data Split System (R-410A) up to 38 SEER, Inverter

7

General Data4MXW3812A10N / 4TXK3812A10NCooling Heating

208 / 230 / 160Hz

12000 12200 2900 -15300 -- 3000- 18700- 8100

4500 / 3510 / 840 5490 / 3570 / 900 788 940 3.9 5.330.5 14.015.25 3.8500/470/440/350/320/270/240

3.0

4MXW3812A10N1400/1300/1200/1100/1000/900/800/550 1400/1270/1200/1130/1050/980/900

0.09Aluminum Fin-Copper Tube

0.282.0 - 0.06

28.1 x 1.0 x 12.01.5/2.5

3.1549/46/43/40/37/34/22

39.2 x 11.9 x 8.9 41.7 x 18.9 x 12.7

29.8 / 36.4

4TXK3812A10NRotary

FV50S (PVE Oil)35

6.91070EEV

0 ~ 129 -22 ~ 75Aluminum Fin-Copper Tube

0.282 - 0.06

30.0 x 2.2 x 21.785030

0.24141017.2

Automatic Defrosting

5335.4 x 23.5 x 14.937.3 x 16.5 x 25.4

99.2 / 105.849915

2.311/41/250100

MODEL - Heat Pump Only

RATED Volts/PHFrequency (Hz)Rated Cooling / Heating Capacity (Btu/h):Minimum Cooling Capacity (@95°F) (Btu/h): 2Maximum Cooling Capacity (@95°F) (Btu/h): 2Minimum Heating Capacity (@47°F) (Btu/h): 2Maximum Heating Capacity (@47°F) (Btu/h): 2Maximum Heating Capacity (@17°F) (Btu/h): 2

Total Capacity (W) (High/Standard/Low):Nominal Power Input (W)Nominal Input Current (A)SEER / HSPFEER / COP (Btu/h)/W Air Flow Volume (CFM) (TURBO/MH/H//M/ML/L/QUIET)Dehumidifying Volume (pt./h)

Indoor Unit Fan Motor Speed (r/min) (TURBO/MH/H//M/ML/L/QUIET)Fan Motor RLA(A)EvaporatorPipe Diameter (inch)Rows - Fin Gap (inch)Coil length (L) x depth (D) x coil width (W) (inch)Output of Swing Motor (W)Fuse (A)Sound PRESSURE Level dB (A)(TURBO/MH/H//M/ML/L/QUIET) 1Uncrated Dimension (W/H/D) (inch)Crated Dimension of Package (L/W/H) (inch)Net Weight /Gross Weight (lbs)

Outdoor UnitCompressor TypeCompressor Oil TypeL.R.A. (A)Compressor RLA(A)Compressor Power Input(W)Throttling MethodWorking Temp Range (°F)CondenserPipe Diameter (inch)Rows - Fin Gap (inch)Coil length (L) x depth (D) x coil width (W) (inch)Fan Motor Speed (rpm) Output of Fan Motor (W)Fan Motor RLA (A)Air Flow Volume of Outdoor Unit (CFM)Fan Diameter (inch)Defrosting Method

Sound PRESSURE Level dB (A)1Uncrated Dimension (W/H/D) (inch)Crated Dimension of Package (L/W/H) (inch)Net Weight /Gross Weight (lbs)Refrigerant Charge (oz)MCAMOP

Connection PipeGas additional charge(oz/ft)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Max Height Distance (ft)Max Length Distance (ft)

1 Sound PRESSURE Level @ 3.3 ft. dB(A)2 Capacities based on fixed compressor speed AHRI validation testing

Page 8: Trane Product Data - R-410A Split System up to 38 SEER Inverter … · 2020. 4. 29. · ©2016 Trane Pub. No. 22-1927-1A-EN Product Data Split System (R-410A) up to 38 SEER, Inverter

8

General Data4MXW3818A10N / 4TXK3818A10NCooling Heating

208 / 230 / 160Hz

18000 18000 4400 -21400 - - 3700 - 24400 - 14200

6300 / 5250 / 1290 7200 / 5250 / 1080 1330 1500 5.7 6.224.5 12.013.5 3.5

740/680/620/560/500/460/3503.8

4MXW3818A10N1400/1300/1200/1100/1000/850/600 1400/1250/1100/1000/1050/900/850

0.24Aluminum Fin-Copper Tube

0.282.0 - 0.06

33.3 x 1.0 x 13.51.5/2.5

3.1551/48/45/42/39/36/34

43.3 x 12.9 x 9.8 45.9 x 15.9 x 13.9

36.4 / 44.1

4TXK3818A10NRotary

RB68EP (POE Oil)30

15.52443EEV

0 ~ 129 -22 ~ 75Aluminum Fin-Copper Tube

0.282.0 - 0.06

37.2 x 1.5 x 29.482090

0.65236021.7

Automatic Defrosting

5939.4 x 31.1 x 16.842.6 x 19.2 x 33.7

141.1 / 152.1742230

5.791/45/850100

MODEL - Heat Pump Only

RATED Volts/PHFrequency (Hz)Rated Cooling / Heating Capacity (Btu/h):Minimum Cooling Capacity (@95°F) (Btu/h): 2Maximum Cooling Capacity (@95°F) (Btu/h): 2Minimum Heating Capacity (@47°F) (Btu/h): 2Maximum Heating Capacity (@47°F) (Btu/h): 2Maximum Heating Capacity (@17°F) (Btu/h): 2

Total Capacity (W) (High/Standard/Low):Nominal Power Input (W)Nominal Input Current (A)SEER / HSPFEER / COP (Btu/h)/W Air Flow Volume (CFM) (TURBO/MH/H//M/ML/L/QUIET)Dehumidifying Volume (pt./h)

Indoor Unit Fan Motor Speed (r/min) (TURBO/MH/H//M/ML/L/QUIET)Fan Motor RLA(A)EvaporatorPipe Diameter (inch)Rows - Fin Gap (inch)Coil length (L) x depth (D) x coil width (W) (inch)Output of Swing Motor (W)Fuse (A)Sound PRESSURE Level dB (A)(TURBO/MH/H//M/ML/L/QUIET) 1Uncrated Dimension (W/H/D) (inch)Crated Dimension of Package (L/W/H) (inch)Net Weight /Gross Weight (lbs)

Outdoor UnitCompressor TypeCompressor Oil TypeL.R.A. (A)Compressor RLA(A)Compressor Power Input(W)Throttling MethodWorking Temp Range (°F)CondenserPipe Diameter (inch)Rows - Fin Gap (inch)Coil length (L) x depth (D) x coil width (W) (inch)Fan Motor Speed (rpm) Output of Fan Motor (W)Fan Motor RLA (A)Air Flow Volume of Outdoor Unit (CFM)Fan Diameter (inch)Defrosting Method

Sound PRESSURE Level dB (A)1Uncrated Dimension (W/H/D) (inch)Crated Dimension of Package (L/W/H) (inch)Net Weight /Gross Weight (lbs)Refrigerant Charge (oz)MCAMOP

Connection PipeGas additional charge(oz/ft)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Max Height Distance (ft)Max Length Distance (ft)

1 Sound PRESSURE Level @ 3.3 ft. dB(A)2 Capacities based on fixed compressor speed AHRI validation testing

Page 9: Trane Product Data - R-410A Split System up to 38 SEER Inverter … · 2020. 4. 29. · ©2016 Trane Pub. No. 22-1927-1A-EN Product Data Split System (R-410A) up to 38 SEER, Inverter

9

General Data4MXW3824A10N / 4TXK3824A10NCooling Heating

208 / 230 / 160Hz

22000 240006800 -30600 - - 6800 - 32400 - 15500

9000 / 6420 / 1980 9480 / 6960 / 19801700 20007.54 9.3721.5 12.013.0 3.5

830/770/720/650/590/500/3804.2

4MXW3824A10N1500/1300/1100/1000/900/850/800 1500/1300/1100/1050/1000/900/850

0.38Aluminum Fin-Copper Tube

0.282 - 0.06

33.3 x 1.0 x 13.51.5/2.5

3.15 52/48/46/44/42/40/37

43.3 x 12.9 x 9.845.9 x 15.9 x 13.9

36.4 / 44.1

4TXK3824A10NRotary

RB68EP (POE Oil) 30.0 16.02443EEV

0 ~ 129 -22 ~ 75Aluminum Fin-Copper Tube

0.282.0 - 0.06

37.8 x 3.4 x 29.482090

0.65236021.7

Automatic Defrosting 59

39.4 x 31.1 x 16.842.6 x 19.2 x 33.7

147.7 / 152.1812235

5.791/45/850100

MODEL - Heat Pump Only

RATED Volts/PHFrequency (Hz)Rated Cooling / Heating Capacity (Btu/h):Minimum Cooling Capacity (@95°F) (Btu/h): 2Maximum Cooling Capacity (@95°F) (Btu/h): 2Minimum Heating Capacity (@47°F) (Btu/h): 2Maximum Heating Capacity (@47°F) (Btu/h): 2Maximum Heating Capacity (@17°F) (Btu/h): 2

Total Capacity (W) (High/Standard/Low):Nominal Power Input (W)Nominal Input Current (A)SEER / HSPFEER / COP (Btu/h)/W Air Flow Volume (CFM) (TURBO/MH/H//M/ML/L/QUIET)Dehumidifying Volume (pt./h)

Indoor Unit Fan Motor Speed (r/min) (TURBO/MH/H//M/ML/L/QUIET)Fan Motor RLA(A)EvaporatorPipe Diameter (inch)Rows - Fin Gap (inch)Coil length (L) x depth (D) x coil width (W) (inch)Output of Swing Motor (W)Fuse (A)Sound PRESSURE Level dB (A)(TURBO/MH/H//M/ML/L/QUIET) 1Uncrated Dimension (W/H/D) (inch)Crated Dimension of Package (L/W/H) (inch)Net Weight /Gross Weight (lbs)

Outdoor UnitCompressor TypeCompressor Oil TypeL.R.A. (A)Compressor RLA(A)Compressor Power Input(W)Throttling MethodWorking Temp Range (°F)CondenserPipe Diameter (inch)Rows - Fin Gap (inch)Coil length (L) x depth (D) x coil width (W) (inch)Fan Motor Speed (rpm) Output of Fan Motor (W)Fan Motor RLA (A)Air Flow Volume of Outdoor Unit (CFM)Fan Diameter (inch)Defrosting Method

Sound PRESSURE Level dB (A)1Uncrated Dimension (W/H/D) (inch)Crated Dimension of Package (L/W/H) (inch)Net Weight /Gross Weight (lbs)Refrigerant Charge (oz)MCAMOP

Connection PipeGas additional charge(oz/ft)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Max Height Distance (ft)Max Length Distance (ft)

1 Sound PRESSURE Level @ 3.3 ft. dB(A)2 Capacities based on fixed compressor speed AHRI validation testing

Page 10: Trane Product Data - R-410A Split System up to 38 SEER Inverter … · 2020. 4. 29. · ©2016 Trane Pub. No. 22-1927-1A-EN Product Data Split System (R-410A) up to 38 SEER, Inverter

10

Performance Data

Capacities in these performance tables reflect normal operation at the temperatures indicated. See specifi-cation tables above for certified values under prescribed test conditions.

Cooling 4TXK3809A/4MXW3809A

DB F DB C TC SHC TC SHC TC SHC TC SHC0 ‐18 8100 6500 8400 6700 8800 7000 9100 73005 ‐15 8800 7000 9000 7200 9500 7600 9800 7800

14 ‐10 10000 8000 10300 8200 10900 8700 11200 890023 ‐5 10600 8500 11000 8800 11600 9200 11900 950032 0 11300 9000 11600 9300 12200 9800 12600 1010041 5 11900 9500 12300 9800 12900 10300 13300 1060050 10 12400 9900 12800 10200 13500 10800 13900 1110059 15 12700 10100 13100 10400 13800 11000 14200 1130068 20 12800 10200 13200 10500 13900 11100 14300 1140077 25 12700 10200 13100 10500 13800 11000 14200 1140086 30 12700 10100 13000 10400 13700 11000 14100 1130095 35 12500 10000 12900 10300 13600 10900 14000 11200

104 40 12000 9600 12400 9900 13100 10400 13400 10700113 45 11600 9300 12000 9600 12600 10100 13000 10400122 50 11500 9200 11800 9400 12400 9900 12800 10200129 54 10300 8200 10600 8500 11100 8900 11500 9200

Heating 4TXK3809A/4MXW3809A68F DB (20C) 73F DB (23C) 80F DB (27C) 82F DB (28C)57F WB (14C) 61F WB (16C) 67F WB (19C) 68F WB (20C)

DB F DB C TC TC TC TC‐22 ‐30 8200 8100 8100 8000‐13 ‐25 9200 9100 9100 9000‐4 ‐20 11800 11700 11700 116000 ‐18 11900 11800 11700 117006 ‐14 12200 12100 12000 1200010 ‐12 12400 12300 12300 1220016 ‐9 12500 12400 12400 1230019 ‐7 13500 13400 13400 1330024 ‐4 13600 13500 13400 1340032 0 13600 13500 13500 1350041 5 13900 13800 13800 1370043 6 14400 14300 14300 1420047 8 13700 13600 13600 1360053 12 13700 13600 13600 1350059 15 13500 13400 13300 1330064 18 13500 13300 13300 1330070 21 12300 12200 12200 1210075 24 12200 12100 12100 1200078 26 11900 11800 11700 11700

Outdoor Coil air

Coil air 57F WB (14C) 61F WB (16C) 67F WB (19C) 68F WB (20C)Outdoor  68F DB (20C) 73F DB (23C) 80F DB (27C) 82F DB (28C)

Page 11: Trane Product Data - R-410A Split System up to 38 SEER Inverter … · 2020. 4. 29. · ©2016 Trane Pub. No. 22-1927-1A-EN Product Data Split System (R-410A) up to 38 SEER, Inverter

11

Performance Data

Capacities in these performance tables reflect normal operation at the temperatures indicated. See specifi-cation tables above for certified values under prescribed test conditions.

Cooling 4TXK3812A/4MXW3812A

DB F DB C TC SHC TC SHC TC SHC TC SHC0 ‐18 8200 6600 8500 6800 8900 7200 9200 74005 ‐15 8900 7100 9100 7300 9600 7700 9900 7900

14 ‐10 10100 8100 10400 8300 11000 8800 11300 900023 ‐5 10700 8600 11100 8900 11700 9300 12000 960032 ‐0 11400 9100 11700 9400 12300 9900 12700 1020041 5 12000 9600 12400 9900 13000 10400 13400 1070050 10 12600 10000 12900 10300 14600 10900 14000 1130059 15 13200 10500 13500 10800 15300 11400 14700 1180068 20 14400 11500 14800 11900 16700 12500 15300 1240077 25 15100 12100 15500 12400 17300 13100 14800 1180086 30 15700 12600 16100 12900 18000 13600 14500 1160095 35 15800 12600 16300 13000 17100 13700 17700 14100

104 40 15200 12100 15600 12500 16400 13100 17000 13600113 45 14500 11600 15000 12000 15800 12600 16300 13000122 50 13300 10600 13700 10900 14400 11500 14800 11900129 54 12600 10100 13000 10400 13700 11000 14100 11300

Heating 4TXK3812A/4MXW3812A68F DB (20C) 73F DB (23C) 80F DB (27C) 82F DB (28C)57F WB (14C) 61F WB (16C) 67F WB (19C) 68F WB (20C)

DB F DB C TC TC TC TC‐22 ‐30 8500 8500 8500 8400‐13 ‐25 9700 9700 9600 9600‐4 ‐20 12200 12100 12100 120000 ‐18 12200 12200 12200 121006 ‐14 13300 13200 13200 13100

10 ‐12 13700 13600 13600 1350016 ‐9 14500 14500 14500 1430019 ‐7 14700 14700 14600 1450024 ‐4 15600 15600 15500 1540032 0 17000 17000 16900 1680041 5 18200 18200 18100 1800043 6 18400 18300 18200 1810047 8 17800 17800 17700 1760053 12 17300 17200 17200 1700059 15 16000 15900 15900 1570064 18 14700 14700 14600 1450070 21 13800 13800 13800 1360075 24 12900 12800 12700 1250078 26 12100 12100 12000 11800

Outdoor Coil air

Coil air 57F WB (14C) 61F WB (16C) 67F WB (19C) 68F WB (20C)Outdoor  68F DB (20C) 73F DB (23C) 80F DB (27C) 82F DB (28C)

Page 12: Trane Product Data - R-410A Split System up to 38 SEER Inverter … · 2020. 4. 29. · ©2016 Trane Pub. No. 22-1927-1A-EN Product Data Split System (R-410A) up to 38 SEER, Inverter

12

Performance Data

Capacities in these performance tables reflect normal operation at the temperatures indicated. See specifi-cation tables above for certified values under prescribed test conditions.

Cooling 4TXK3818A/4MXW3818A

DB F DB C TC SHC TC SHC TC SHC TC SHC0 ‐18 8800 6500 9200 7000 10600 8100 11300 89005 ‐15 10300 8000 10700 8500 12100 9600 12800 10400

14 ‐10 11800 9200 12500 9800 13800 11000 14000 1130023 ‐5 12700 9900 13800 10900 15600 12500 16100 1300032 ‐0 13200 10300 14300 11300 16200 13000 16500 1330041 5 13900 10800 14900 11700 16600 13200 17000 1380050 10 14800 11600 15800 12500 17100 13700 17600 1430059 15 15700 12200 16900 13300 17600 14100 18000 1460068 20 16200 12600 17300 13700 18200 14500 18700 1520077 25 16900 13100 18100 14300 19000 15200 19500 1580086 30 16400 12800 17700 13900 18600 14900 19000 1540095 35 15800 12300 17200 13600 18100 14500 18600 15000

104 40 15500 12000 17100 13500 18000 14400 18200 14700113 45 15100 11700 14700 11600 17900 14300 18000 14500122 50 14900 11600 15200 12000 17100 13700 17600 14300129 54 14100 10800 14400 11100 16200 12800 16800 13400

Heating 4TXK3818A/4MXW3818A68F DB (20C) 73F DB (23C) 80F DB (27C) 82F DB (28C)57F WB (14C) 61F WB (16C) 67F WB (19C) 68F WB (20C)

DB F DB C TC TC TC TC‐22 ‐30 10000 9600 9300 9000‐13 ‐25 13400 13000 12700 12400‐4 ‐20 17300 16900 16600 163000 ‐18 18200 17800 17500 172006 ‐14 20600 20000 19600 19300

10 ‐12 21400 21000 20600 2020016 ‐9 23400 23000 22800 2240019 ‐7 24200 23800 23400 2320024 ‐4 24200 24000 23800 2360032 0 24600 24200 24000 2360041 5 24800 24400 22000 2180043 6 25000 24600 24400 2400047 8 24200 24000 23800 2340053 12 23400 23000 22800 2260059 15 22600 22400 22200 2200064 18 21600 21400 21000 2080070 21 20400 20000 19900 1960075 24 19200 18900 18700 1840078 26 18600 18200 17900 17700

Outdoor Coil air

73F DB (23C) 80F DB (27C) 82F DB (28C)Coil air 57F WB (14C) 61F WB (16C) 67F WB (19C) 68F WB (20C)Outdoor  68F DB (20C)

Page 13: Trane Product Data - R-410A Split System up to 38 SEER Inverter … · 2020. 4. 29. · ©2016 Trane Pub. No. 22-1927-1A-EN Product Data Split System (R-410A) up to 38 SEER, Inverter

13

Performance Data

Capacities in these performance tables reflect normal operation at the temperatures indicated. See specifi-cation tables above for certified values under prescribed test conditions.

Cooling 4TXK3824A/4MXW3824A

DB F DB C TC SHC TC SHC TC SHC TC SHC0 ‐18 13500 10500 14100 11100 15800 12400 15700 123005 ‐15 14000 11000 14800 11600 16700 13100 17400 13600

14 ‐10 14300 11200 15200 11900 17300 13600 18000 1410023 ‐5 15300 12000 16400 12900 18800 14700 19600 1540032 ‐0 18600 14600 19900 15600 21800 17100 23800 1870041 5 21000 16500 22400 17500 23800 18800 25600 2000050 10 20800 16300 22000 17400 23600 18600 25400 1990059 15 20200 15900 21600 17000 23400 18400 25000 1960068 20 19800 15500 21000 16600 23000 18100 24600 1940077 25 19300 15100 20600 16100 22600 17700 24400 1910086 30 18600 14600 19900 15600 21800 17100 23800 1870095 35 18700 14700 20000 15700 22000 17200 24000 18800

104 40 17700 13900 19000 14900 21000 16500 22800 17900113 45 16400 12900 17600 13800 19700 15400 21200 16600122 50 14800 11600 16000 12500 17900 14000 19300 15100129 54 13700 10800 14600 11500 16500 12900 17100 13400

Heating 4TXK3824A/4MXW3824A68F DB (20C) 73F DB (23C) 80F DB (27C) 82F DB (28C)57F WB (14C) 61F WB (16C) 67F WB (19C) 68F WB (20C)

DB F DB C TC TC TC TC‐22 ‐30 14100 13900 13600 13300‐13 ‐25 18700 18400 18000 17600‐4 ‐20 23200 22800 22400 220000 ‐18 24000 23600 23000 226006 ‐14 24200 23800 23200 22800

10 ‐12 24600 24200 23800 2320016 ‐9 25200 24600 24200 2360019 ‐7 25600 25200 24600 2420024 ‐4 25800 25400 25000 2440032 0 26000 25600 25200 2480041 5 27400 27000 26600 2620043 6 27800 27600 27200 2680047 8 29200 28600 28000 2740053 12 29400 29000 28400 2760059 15 30200 29600 29000 2840064 18 30800 30200 29600 2900070 21 31400 30800 30200 2940075 24 31800 31200 30600 2980078 26 32200 31600 31000 30400

Outdoor Coil air

Coil air 57F WB (14C) 61F WB (16C) 67F WB (19C) 68F WB (20C)Outdoor  68F DB (20C) 73F DB (23C) 80F DB (27C) 82F DB (28C)

Page 14: Trane Product Data - R-410A Split System up to 38 SEER Inverter … · 2020. 4. 29. · ©2016 Trane Pub. No. 22-1927-1A-EN Product Data Split System (R-410A) up to 38 SEER, Inverter

14

Mechanical Specifications

Single Zone Indoor High Wall

General

The High Wall mounted type air handler shall be completely factory assembled including coil, condensate drain pan, fan motor, washable filter, air purifying filter and electric controls to be used with a wireless remote controller. Unit shall be shipped with a unit mounting plate. Unit shall be matched with an American Standarad outdoor unit, rated and tested in accordance with AHRI standard. Unit shall be ETL listed.

Unit Casing

Casing shall be provided with knockouts on the right, and left of the unit to facilitate piping and electrical connection on either side of the unit. An electrical service cover shall be provided to permit easy access to the electrical terminal strip.

Discharge Airflow and Distribution System

Unit shall have auto swing, dual horizon-tal blades to optimize the aperture outlet for vertical airflow and air distribution. Blade shall close automatically when the air conditioner is turned off to minimize dust entering the unit. Five-Step preset program on the remote controller shall be available to control the blade angle.

Manually adjusted wide-angle louvers shall be provided to adjust the coverage and direction of airflow.

Controls

Units shall have the capability to be con-trolled remotely.

Remote Controller

The unit shall have a wireless infrared remote controller with an easily read-able digital display panel to start, stop and regulate the air conditioner from a distance.

The wireless controller is available for all units. (Sold separately)

Healthy Filters

The unit shall have one combined active carbon and catechin filter with the unit.The filter needs to be cleaned at least once a year.

Single Zone Outdoor Unit

General

This unit is fully charged from the factory for 25 feet of piping. This unit is designed to operate at outdoor ambient tempera-tures as high as 129°F. Cooling capacities with the mini-split air handler shown in the catalog are AHRI certified. The unit is ETL listed for outdoor application.

Unit Casing

The unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint.

Refrigerant Controls

Refrigeration system controls include condenser fan and compressor relay. High and low pressure controls are inher-ent to the compressor. A suction line multi function service valve is standard

Compressor

The compressor features internal over temperature and pressure protection; to-tal dipped hermetic motor windings. Other features include: centrifugal oil pump and low vibration and noise.

Condenser Coil

The coil shall consist of aluminum finned coils brazed to copper tubing. The coil provides air flow resistance and efficient heat transfer. The coil is protected by the casing.

Low Ambient Cooling

Matched 38 SEER Trane ductless prod-ucts, have a cooling capability to 0° F and heating capability to -22° F.

09/16

The manufacturer has a policy of continuous product and product data improvement and it reserves the right

to change design and specifications without notice.

Trane6200 Troup HighwayTyler, TX 75707-9010