Page 1: TSL.R.020 Ribbon tap install EU · TSL.R.020 RIBBON SENSOR TAP MANUAL 7 Power Supply The Ribbon tap system is provided with the means for either battery or mains power supplies. North

TSL.R.020Sensor Tap

inst

alla

tion

+ m

aint

enan

ce

Page 2: TSL.R.020 Ribbon tap install EU · TSL.R.020 RIBBON SENSOR TAP MANUAL 7 Power Supply The Ribbon tap system is provided with the means for either battery or mains power supplies. North

3 Safety and Warnings

4 Box Contents

5 Technical Data

7 Before You Install

8 How to Install

11 The Complete System

12 Resetting the Sensor

14 Maintenance

14 Cleaning

15 Spare Parts

15 Product Identification

16 Troubleshooting

17 Warranty

18 Contact Details

contents

2 TSL.R.020 RIBBON SENSOR TAP MANUAL

Page 3: TSL.R.020 Ribbon tap install EU · TSL.R.020 RIBBON SENSOR TAP MANUAL 7 Power Supply The Ribbon tap system is provided with the means for either battery or mains power supplies. North

For more information contact:

Tel: +44 (0)161 482 7000

Email: [email protected]

TSL.R.020 ribbon sensor tap

Read and save these instructions

WARNING !To reduce the risk of fire, electric shock or injury to persons, observe the following:

+ Use this unit in the manner intended by the manufacturer. If you have questions, contact the manufacturer

+ This equipment should be installed in a way that ensures all electrical parts are kept dry.

+ A means of electrical isolation must be incorporated in the fixed wiring, in accordance with the current local regulations in force.

+ Disconnect the power supply before performing any maintenance on the product

+ Children should not play with this equipment. Cleaning and maintenance shall not be performed by children without supervision.

+ This equipment is designed to be used in commercial and public areas; it is not intended for domestic or residential use.

+ Replace fuse only with the same type and rating of fuse.

+ Ensure wiring and cover is installed correctly before connecting to live power supply.

+ If in doubt, consult an electrician.

TSL.R.020 RIBBON SENSOR TAP MANUAL 3

Page 4: TSL.R.020 Ribbon tap install EU · TSL.R.020 RIBBON SENSOR TAP MANUAL 7 Power Supply The Ribbon tap system is provided with the means for either battery or mains power supplies. North

4 TSL.R.020 RIBBON SENSOR TAP MANUAL

box contents

AB

C

D

E

F

G

I

H

A Ribbon sensor tap head

B Mains power supply

C Battery supply

D Anti-rotation plate #1

E Counter top gasket

F Anti-rotation plate #2

G Fixing nut

H Solenoid and cable

I Flow restrictor

Page 5: TSL.R.020 Ribbon tap install EU · TSL.R.020 RIBBON SENSOR TAP MANUAL 7 Power Supply The Ribbon tap system is provided with the means for either battery or mains power supplies. North

TSL.R.020 RIBBON SENSOR TAP MANUAL 5

Finishes TSL.R.020.C.ELE Bright Polished Stainless steel TSL.R.020.CS.ELE Brushed Stainless steel TSL.R.020.CP.ELE Brushed Copper TSL.R.020.BK.ELE Brushed Black TSL.R.020.BR.ELE Brushed Brass TSL.R.020.BZ.ELE Brushed Bronze TSL.R.020.C.BAT Bright Polished Stainless steel TSL.R.020.CS.BAT Brushed Stainless steel TSL.R.020.CP.BAT Brushed Copper TSL.R.020.BK.BAT Brushed Black TSL.R.020.BR.BAT Brushed Brass TSL.R.020.BZ.BAT Brushed Bronze

Material (body) AISI304 Stainless steel

Operating pressure 0.2 – 10 bar dynamic pressure

Flow rate 1.89 lpm (0.5 GPM) (Other flow rates available on request)

Water supply Premixed through thermostatic mixing valve (supplied by others)

Weight 1kg (2lb 3oz)

Power supply - Mains Input 100 – 240V - 50-60Hz / 1.5A Output 6V DC, 1A, 6W max Low voltage connector - two-pin waterproof plug

Power supply – Battery 6V Type CR-P2 lithium

Power supply – IP rating IP55

Sensor range – Preset 12cm

Sensor range – Minimum 5cm +/-20%

Sensor range – Maximum 25cm +/-20%

Comfort delay 2 seconds

Security time 30 seconds

Maximum water temp 50°C

Warranty 3 years parts and 1 year parts and labour, from date of purchase

technical data

Page 6: TSL.R.020 Ribbon tap install EU · TSL.R.020 RIBBON SENSOR TAP MANUAL 7 Power Supply The Ribbon tap system is provided with the means for either battery or mains power supplies. North

6 TSL.R.020 RIBBON SENSOR TAP MANUAL

technical data

FRONT SIDE

126

186

143

115

91

O 32

10 MIN35 MAX

69

54

1/2" BSP

MAX Length300mm

150mm

DefaultSensorRange120mm

O 34Through Hole

BatteryPower Supply

MainsPower Supply

Page 7: TSL.R.020 Ribbon tap install EU · TSL.R.020 RIBBON SENSOR TAP MANUAL 7 Power Supply The Ribbon tap system is provided with the means for either battery or mains power supplies. North

TSL.R.020 RIBBON SENSOR TAP MANUAL 7

Power Supply

The Ribbon tap system is provided with the means for either battery or mains power supplies.

North American mains systems are fitted with a NEMA 1-15 plug suitable for 120V supply. European systems are provided with WAGO connectors to accept 2 core power cables from 240V mains supply. If the WAGO connectors are not used, it is recommended that the cable ends are remade as not all mains connection terminals will accept soldered cables.

Changing the Battery

Battery operated systems utilise a CR-P2 6V battery. If this needs changing, simply unscrew and remove the holder cover and replace the battery (ensuring the correct polarity). Aªx the cover and tighten the screws; making sure the cable is fed through the purpose made grooves in the holder.

Flow Rates

Different flow rates may need to be achieved. The Splash Lab offer a number of flow regulators which can be used in conjunction with the Ribbon Tap system (see installation guide or contact The Splash Lab for more information).

Water Temperature

The Ribbon Tap System does not come equipped with temperature control. Premixed water must therefore be supplied separately.

Sinks

Use of a The Splash Lab sink is recommended when used in conjunction with any of the The Splash Lab Ribbon taps.

When using other sinks, ensure that holes and appropriate mounting points are created in accordance with the diagram below.

before you install

Page 8: TSL.R.020 Ribbon tap install EU · TSL.R.020 RIBBON SENSOR TAP MANUAL 7 Power Supply The Ribbon tap system is provided with the means for either battery or mains power supplies. North

8 TSL.R.020 RIBBON SENSOR TAP MANUAL

1Ensure internal anti-rotation ring (D) and the gasket (E) are fitted into the recesses in the Ribbon sensor tap head (A). These should be shipped preinstalled.

*Ensure that the mains water supply has been deactivated at or before point of install prior to fitting.

2Position tap on sink deck through a Ø32mm (1 1/4”) hole and ensure the tap is angled pointing in the required direction.

*Remove reflective clothing during installation

how to install

Page 9: TSL.R.020 Ribbon tap install EU · TSL.R.020 RIBBON SENSOR TAP MANUAL 7 Power Supply The Ribbon tap system is provided with the means for either battery or mains power supplies. North

TSL.R.020 RIBBON SENSOR TAP MANUAL 9

3This tap can be fitted to a variety of sink types:

The Splash Lab Approved Sink

a. When using an approved The Splash Lab Ribbon sink, there will be a recess available for the under-sink anti- rotation plate (F). No fixings are required at this stage.

Alternative solid-surface Sink

b. When using another solid-surface sink, micro squirrel fixings will need to be fitted prior to install. The under- sink anti-rotation plate (F) can be secured in place with 2x M4/M5 fixings.

The Splash Lab Approved Sink

c. Other scenarios will require a soªt of timber or MDF (I) to be fitted under the sink. The under-sink anti-rotation plate (F) can be secured in place with 2x no.10 screws.

Page 10: TSL.R.020 Ribbon tap install EU · TSL.R.020 RIBBON SENSOR TAP MANUAL 7 Power Supply The Ribbon tap system is provided with the means for either battery or mains power supplies. North

10 TSL.R.020 RIBBON SENSOR TAP MANUAL

how to install

4Attach the Ribbon fixing nut (G) with the flat surface towards the sink. We recommend tightening to 15-20 Nm, however this is subject to the sink material and install situation.

5Fit the end of the flexi-hose onto the outlet of the solenoid, ensuring that the flow restrictor is in place, between the fixing nut and the solenoid valve.

6Connect the solenoid inlet to the mains water supply using a flexi-hose only (not supplied)

7Before powering on the system, remove the label covering the sensor at the front of the tap (left).

8Attach the female sensor cable from the main unit to either the battery pack (C) or mains power supply (B) as required.

Page 11: TSL.R.020 Ribbon tap install EU · TSL.R.020 RIBBON SENSOR TAP MANUAL 7 Power Supply The Ribbon tap system is provided with the means for either battery or mains power supplies. North

TSL.R.020 RIBBON SENSOR TAP MANUAL 11

the complete system

Water Aerator

Mains Water Supply Flexi-Hose

110-240 Volt Mains Supply

A

B

C

H

I

B

C

A

B

C

H

I

A

B

C

H

I

A Ribbon sensor faucet head

B Mains power supply

C Battery supply

H Solenoid and cable

I Flow restrictor

Page 12: TSL.R.020 Ribbon tap install EU · TSL.R.020 RIBBON SENSOR TAP MANUAL 7 Power Supply The Ribbon tap system is provided with the means for either battery or mains power supplies. North

12 TSL.R.020 RIBBON SENSOR TAP MANUAL

resetting the sensor

1Firstly disconnect the Ribbon Tap head from the Power unit. Wait a minimum of 4 seconds and reconnect the power.

2Look under the tap at the sensor near the nozzle. You should see a flashing red light. When you see the light position your hand within 5cm (2”) of the tap. If you do not see the light, repeat from step 1.

Page 13: TSL.R.020 Ribbon tap install EU · TSL.R.020 RIBBON SENSOR TAP MANUAL 7 Power Supply The Ribbon tap system is provided with the means for either battery or mains power supplies. North

TSL.R.020 RIBBON SENSOR TAP MANUAL 13

3When the light stops flashing move your hand down to the desired activation position and hold.

4When the light goes out the new detection distance is set. Test the system and repeat from step 1 until the tap works as required.

*Remove reflective clothing during installation

Page 14: TSL.R.020 Ribbon tap install EU · TSL.R.020 RIBBON SENSOR TAP MANUAL 7 Power Supply The Ribbon tap system is provided with the means for either battery or mains power supplies. North

14 TSL.R.020 RIBBON SENSOR TAP MANUAL

cleaning

External parts should be cleaned with a soft cloth and a mild solution of soapy water as part of the regular cleaning regime. Do not use acidic, abrasive or cream cleaners as these will damage the surface finish.

maintenance

Some of the components in the Ribbon system are liable to fail over time and may need maintenance and replacing. The Ribbon system has been developed to accommodate for this maintenance yet all work should be done by a trained member of an approved maintenance team. For more information, contact The Splash Lab.

Page 15: TSL.R.020 Ribbon tap install EU · TSL.R.020 RIBBON SENSOR TAP MANUAL 7 Power Supply The Ribbon tap system is provided with the means for either battery or mains power supplies. North

TSL.R.020 RIBBON SENSOR TAP MANUAL 15

spare parts

If a situation arises where you require replacement components outside of a maintenance contract, there may be provision to obtain spare parts. Providing the components are under warranty and the parts have become non-functioning during normal use within their assumed usable life, they may be replaced. Should a replacement mains power supply be required it is imperative that an identical type is used. Contact The Splash Lab for further information.

product identification

A unique product identification code can be found on the product tag attached to the water hose.

Page 16: TSL.R.020 Ribbon tap install EU · TSL.R.020 RIBBON SENSOR TAP MANUAL 7 Power Supply The Ribbon tap system is provided with the means for either battery or mains power supplies. North

16 TSL.R.020 RIBBON SENSOR TAP MANUAL

Corrective Actions for Initial Installation Failures

Water does not flow / Cannot hear valve open

troubleshooting

We are always looking to improve. If these did not solve your problem please contact us and we will endeavour to help.

Tel: +44 (0)161 482 7000Email: [email protected]

+ There is no power to valve or sensor

+ Check that cables are connected

+ Check that transformer is operating and supplying 6 volts

+ Replace battery on battery powered versions

+ Sensor range is incorrect

+ Adjust sensor settings (see page 10 and 11, or contact The Splash Lab to purchase remote controller

Water does not flow / Valve can be heard to open

+ Water supply is blocked to valve

+ Check and clean filter on solenoid valve

+ Check water supply for any blockages or restrictions

+ Water pressure is too low

+ Check pressure of water supply

Water does not flow / Sensor light is flashing all the

+ Sensor light is flashing all the time Supply voltage has dropped below 5.4V

+ Check power supply and if necessary replace battery or transformer

Page 17: TSL.R.020 Ribbon tap install EU · TSL.R.020 RIBBON SENSOR TAP MANUAL 7 Power Supply The Ribbon tap system is provided with the means for either battery or mains power supplies. North

TSL.R.020 RIBBON SENSOR TAP MANUAL 17

warranty

We believe the future is personal. With a global mindset, we challenge conventional restroom norms via product innovation to create considered washroom solutions for corporate and educational spaces. We use rich raw materials, cutting-edge automation and considered washroom design to powerfully and positively influence the lives of people. We are The Splash Lab.

Demonstrating our commitment to quality and our belief in the strength of our designs, we can offer the following warranties.

The Splash Lab will warrant that its products will be free of manufacturing and material defects during normal use and environmental conditions as detailed below:

Sensor taps 2 years’ parts & labour

If a defect is found in normal use, The Splash Lab will, at their discretion, repair, provide a replacement part or product, or make appropriate adjustments. Damage caused by accident, misuse, or abuse is not covered by this warranty. Improper care and cleaning will void the warranty.

Non-operation of the product due to environmental conditions beyond our control, installation error, incorrect maintenance, water quality, fair wear and tear, incorrect or inappropriate installation, misuse and abuse is not covered by the warranty.

Proof of purchase (original sales receipt) must be provided to The Splash Lab with all warranty claims.

The above warranty is valid for goods supplied within the United Kingdom.

For goods supplied outside of the United Kingdom, The Splash Lab will honour the above stated warranty periods for the parts only.

THE SPLASH LAB DISCLAIM ANY LIABILITY FOR SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES.

Page 18: TSL.R.020 Ribbon tap install EU · TSL.R.020 RIBBON SENSOR TAP MANUAL 7 Power Supply The Ribbon tap system is provided with the means for either battery or mains power supplies. North

18 TSL.R.020 RIBBON SENSOR TAP MANUAL

contact

General information

[email protected] +44 (0) 161 482 7000

Technical support

[email protected]

For further contact information visit:

www.thesplashlab.com

Page 19: TSL.R.020 Ribbon tap install EU · TSL.R.020 RIBBON SENSOR TAP MANUAL 7 Power Supply The Ribbon tap system is provided with the means for either battery or mains power supplies. North

TSL.R.020 RIBBON SENSOR TAP MANUAL 19

The Splash Lab (Holdings) Ltd, T 0161 482 7000 [email protected] Pavilion View, Newby Rd, Stockport SK7 5DA F 016 1 482 7050 www.thesplashlab.com

EU Declaration of Conformity In accordance with EN ISO 17050-1:2010 Object of the declaration:

Product Sensor Tap Model/type L-R021, L-R022 Ribbon deck mounted tap Manufacturer The Splash Lab (Holdings) Ltd Address Unit 27, Pavilion View, Stockport, SK7 5DA, UK

This declaration is issued under the sole responsibility of the manufacturer. The technical documentation for the equipment is available from the manufacturer at the above address.

The object of the declaration described above is in conformity with the relevant Union harmonisation legislation:

2006/42/EC The Machinery Directive

2014/30/EU The Electromagnetic Compatibility Directive

2009/125/EC The Ecodesign of Energy-related Products Directive

2011/65/EU The Restriction of Hazardous Substances Directive

Conformity is shown by compliance with the applicable requirements of the following documents:

Reference & Date Title EN 60335-2-23:2003 +A2:2015

Household and similar electrical appliances. Safety. Particular requirements for appliances for skin or hair care

EN 60335-1:2012 +A11:2014 Household and similar electrical appliances. Safety. General requirements

EN 62233:2008 Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure

EN 55014-1:2006 +A2:2011 Electromagnetic compatibility — Requirements for household appliances, electric tools and similar apparatus — Part 1: Emission

EN 55014-2:1997 +A2:2008 Electromagnetic compatibility — Requirements for household appliances, electric tools and similar apparatus — Part 2: Immunity — Product family standard

EN 61000-3-2:2014 Electromagnetic compatibility (EMC) — Part 3-2: Limits — Limits for harmonic current emissions (equipment input current 16 A per phase)

EN 61000-3-3:2013 Electromagnetic compatibility (EMC) — Part 3-3: Limits — Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection

(EC) No 1275/2008 Ecodesign requirements for standby and off mode, and networked standby, electric power consumption of electrical and electronic household and office equipment

EN 50564:2011 Electrical and electronic household and office equipment - Measurement of low power consumption

(EC) No 278/2009 Ecodesign requirements for no-load condition electric power consumption and average active efficiency of external power supplies

EN 50581:2012 Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances

Signed for and on behalf of: The Splash Lab (Holdings) Ltd

Place of issue: Stockport

Date of issue: 28 March 2018

Name: Adrian Cooper

Position: Quality Assurance Manager

Signature:

Page 20: TSL.R.020 Ribbon tap install EU · TSL.R.020 RIBBON SENSOR TAP MANUAL 7 Power Supply The Ribbon tap system is provided with the means for either battery or mains power supplies. North

TSL

.R.0

20• (

EUR

) • R

EV

2-0

4/0

4/18