turnitin result 4 project
TRANSCRIPT
-
8/3/2019 Turnitin Result 4 Project
1/4
Turnitin Originality Report
Behavior of RCC and Steel building underSeismic loading by Syed Abbas Ahmed,Sriram Charanteja, P.rama
From Behavior of RCC and Steel buildingunder Seismic loading (students)
Processed on 04-18-11 3:41 AM PDTID: 182356269Word Count: 1088
Similarity Index
8%
Similarity by Source
Internet Sources: 3%Publications: 7%Student Papers: 5%
sources:
2% match (publications)
Minh Phono Luong. "Infrared thermovision of damage processes in concrete and rock",Engineering Fracture Mechanics, 1990
1% match (publications)
Adang Surahman. "Earthquake-resistant structural design through energy demand andcapacity", Earthquake Engineering & Structural Dynamics, 11/2007
1% match (Internet from 8/28/10)
http://iisee.kenken.go.jp/worldlist/24_India/24_India_Comments.pdf
1% match (publications)Nageswara Rao, M.. "Environmentally assisted cracking of 18%Ni maraging steel", CorrosionScience, 200908
1% match (Internet from 11/12/08)
http://www.unipune.ernet.in/stud_info/Syllabi/Faculty%20of%20Engineering/4.%20ME%20Civil%20Structure.pdf
1% match (publications)
Frank, J.. "Short-term effects of liming and vitality fertilization on forest soil and nutrientleaching in a Scots pine ecosystem in Norway", Forest Ecology and Management, 20030317
1% match (student papers from 04/11/11)
Class: studentsAssignment:
Paper ID: 181197349
1
2
3
4
5
6
7
paper text:
Behavior of RCC and Steel building under Seismic loading. Syed Abbas Ahmed, Sriram Charanteja, an
P.Rama Mohan Rao
Page 1 of 4Turnitin Originality Report
4/18/2011http://www.turnitin.com/newreport_printview.asp?eq=0&eb=0&esm=0&oid=1823562...
-
8/3/2019 Turnitin Result 4 Project
2/4
4School of Mechanical and Building Sciences, VIT University, Vellore-
632014, Tamil Nadu, India.
1and 2 M.Tech Structural engineering student, 3. Assistant professor VIT,Vellore. ABSTRACT: Severedamage and poor performance of RCC and steel buildings during earthquakes is a matter of serious
concern. Keeping this in mind analytical comparison of multi-storey RCC and steel building is done by usi
ETABS software using dynamic analysis, non linear static analysis and p-delta and design as per is 456-
2000 and is 800-1998.from the results given by ETABS, the critical beam and column are identified in the
structure. The designed 30 storey building is analytically compared with RCC and steel frame with shear
walls provided in same manner in both the structures. From the results the salient features of earthquake
resistant design and the structural efficiency of earthquake resistant structure is explained. Keywords:
Earthquakes, structural efficiency, shear wall, critical beam, critical column, stress analysis, seismic desig
Introduction: Earthquakes are wave like motions generated by forces in constant turmoil under the surfac
the earth causing dislocation of the crust. These vibrations cause rapture and sudden movement of rocks
that have been stained beyond their elastic limit. Some of effects of earthquake on various structural
components are tearing of slabs at discontinuities and junction with vertical elements, shear cracking in t
beam column intersection zone, cracking in tension zone, stirrups bursting out, failure of internal and
external walls, collapse of entire structure, and the most important is cracking of concrete which leads to
degradation in the cracked zone.
1Most severe likely earthquake can only be survived, if members are
sufficiently ductile to absorb and dissipate seismic energy by inelastic
deformation.rcc members are almost exclusively concerned with strength, while ductility and energy
absorption receive little consideration. thus, for RCC members to have adequate strength and ductility to
with stand earth quakes their design and detailing must conform is 456-2000 and is13920-2002. a
comparative study of the two structures on the basis of shear wall is done to find the structural efficiency.
LITERATURE REVIEW: Seismic analysis is a subset of structural analysis. In the paper, "A seismic desi
of multistory RCC" A.R.Chandrasekaran and D.S.PrakashRao, equivalent static method for the design
buildings "Seismic vulnerability of columns of RCC earthquake resistant structures has been explained. I
the paper, building framed Sharanyhaque, the collapse of columns due to seismic force has beenexplained. The ductility design of column based on equivalent static method has been explained. In the
paper,
2"Earthquake resistant structural design through energy demand and
capacity"
Adangsurahman 1 June 2007,
Page 2 of 4Turnitin Originality Report
4/18/2011http://www.turnitin.com/newreport_printview.asp?eq=0&eb=0&esm=0&oid=1823562...
-
8/3/2019 Turnitin Result 4 Project
3/4
2an energy based earthquake resistant structural design has been proposed
using equivalent static "A method for non-linear seismic analysis of regular load method. In the paper,
building" Peterfajfar and Matij 2-9-1988 the Stiffness, strength and ductility are determined by staticanalysis. In the paper, "Ductile shear wall in earthquake resistant multistory building" Markfinten 1-1-19
the role and "Seismic performance of RCC shear design of shear wall for seismic resistance is discussed
the paper, bracing walls W.L.Cao 1-1-2003, the importance of shear wall in improving the seismic
performance of building structure has been discussed. Thus, reviewing the papers mentioned above and
other references the present paper which deals with the analytical design of earthquake resistant structur
and comparison of structural efficiency has been carried out. ANALYSIS OF MULTI-STOREY RCC
BUILDING: The analysis of the multi-storey RCC building was carried out in ETABS software using Dyna
analysis and P-Delta effect. The design was carried out in ETABS using IS 456-2000. The preliminary da
with which the R.C.C structure has been modeled is given in table 1 and for Steel Structure is given in Ta
2. Table: 1 (R.C.C) No. of stories G + 14 Ground storey height 3.1m Floor to Floor height 3.1m Materials:
M20 and Fe415 steel. Size of column 700mmx700mm Size of Beam 500mmx500mm Depth of Slab 200
thick Loading Details for R.C.C: Dead load of the structure is computed by the software based on the
dimension and weights assigned of the different members. Live load on the floor 4KN/m as per IS875
code, weight of slab 25D, weight of walls has been calculated as per IS1911-1967. The Earthquake loa
is given as per IS1893-2002 (part 1), the zone considered for analysis is zone IV as per clause 6.4.2 and
table 2, the response reduction factor is 5 from table 7, the importance factor is taken as 1.5 from table 6,
the rock and soil factor is 2.5 from fig. 2 and damping ratio is 5. Load Combinations: As per IS1893-2002
31.5(DL+LL) ? 1.2(DL+LL+EL) ? 1.5(DL+EL) ? 0. 9DL +1.5EL
Table 2: (Steel) No. of stories G + 14 Ground storey height 3.1m Floor to Floor height 3.1m Materials: Fe
steel. Slab thickness: 200mm concrete. Steel section used: Optimized sections analyzed by the software.
Loading details for Steel: Dead load of the structure was calculated by the software based on the size an
weight of the different members. Live load on floor 4KN/m. The Earthquake loads is given as per IS1893-
2002 (part 1), the zone considered for analysis is zone IV as per clause 6.4.2 and table 2, the response
reduction factor is 5 from table 7, the importance factor is taken as 1.5 from table 6, the rock and soil fact
is 2.5 from fig. 2 and damping ratio is 2. Load Combinations: As per IS1893-2002 ? 1.7
6(D.L + L.L) ? 1.7(D.L+ E .L) ? 1.
3(D.L+L.L+E.L) Results and Discussions: For R.C.C: The most critical loading condition for the structure i
combination 5, i.e. 1.5(D.L+E.L). The Bending moment, shear force and deflection diagrams are given fo
critical beam element. The storey drifts for the building: in mm Base Shear of the structure: The design
details for a column and beam are: The design details for Shear wall: For Steel: The critical combination
found out to be: 1.3(D.L+L.L+E.L) The bending moment, shear force and deflection for critical beam are:
The storey drifts are: Base Shear of the structure: The section details: Conclusion: Multi-storey R.C.C
building has lesser top storey drift than Steel. And the base shear at bottom storey for R.C.C is lesser tha
Page 3 of 4Turnitin Originality Report
4/18/2011http://www.turnitin.com/newreport_printview.asp?eq=0&eb=0&esm=0&oid=1823562...
-
8/3/2019 Turnitin Result 4 Project
4/4
that of steel. Therefore it is analyzed that R.C.C structure is more economical and effective against
earthquake resistant design than Steel structure. References: 1. IS1893-2002,
7Criteria for earthquake resistant design of structures, part 1.
2. IS13920,
5Ductile detailing of reinforced concrete structures subjected to seismic
force.
Bureau of Indian Standards. 3. Earthquake Resistant design of Structures by Pankaj Agarwal and Manis
Shrikande.
Page 4 of 4Turnitin Originality Report
4/18/2011http://www turnitin com/newreport printview asp?eq=0&eb=0&esm=0&oid=1823562