Page 1: Ultra Slim DC Power Supplies - Matsusada Precision Inc.matsusada.com/dc/rk80/RK80.pdffor purpose to avoid mis-operation when controlled. Function to output ON/OFF of total 32 units

NEW

Ultra Slim DC Power Supplies

www.matsusada-us.com

Sharp VersatileSharp VersatileSharp Versatile

RK-80 series

Ultra Slim DC Power Supplies

Page 2: Ultra Slim DC Power Supplies - Matsusada Precision Inc.matsusada.com/dc/rk80/RK80.pdffor purpose to avoid mis-operation when controlled. Function to output ON/OFF of total 32 units

Power factor correction and

universal input

New user-friendly functions

Compact and light weight space

saving design

With low noise switching method

ideal for research purpose

Various operations by connecting multiple power supplies, such as master/slave, is possible.

For wider output rangeRK-80L:16V/10ARK-80:36V/5A

RK-80M:110V/1.3ARK-80H:320V/0.5A

4 different models with various

output voltages

80L

80M 80H

80

RK-80 series

1.38"(35mm)

4.88"(124mm)

RK-80

36V/2.2A

16V/5A

No.1

No.2

No.3

Quick access to the function needed

Ultra Slim DC Power SuppliesNEW

New and useful functions and stylish front panel design!

Useful new feature of variable setting range

Set voltage/current value within 80W, then turn on output *Not automatic range change which can output 80W all the time. Resetting is required.

10.63"(270mm)10.63"(270mm)

RK-80 series is DC regulated power supply which has two time wider output setting range. For example standard

80W 36V model is enable to set up to 2.2A current (80W 36V), but RK-80 is enable to set maximum 5A, and has

both setting range of 36V/2.2A and 16V/5A.

Further more, the size 1/3, and weight is 1/5 of standard 80W power supply. Featuring OVP, OCP, 3 individual

presets and locking function, RK-80 is high cost performance model.

02

Preset setting is automatically displayed when output is off.

OCP is added for more safety operation.

Quick lock with one touch action.Two selectable lock options.

Page 3: Ultra Slim DC Power Supplies - Matsusada Precision Inc.matsusada.com/dc/rk80/RK80.pdffor purpose to avoid mis-operation when controlled. Function to output ON/OFF of total 32 units

03

9

Function to memorize 3 different voltage and current settings in addition to standard preset function.No need to adjust the output when different setting, and convenient function for production inspection process or testing which require frequent data taking.

Lock all the function other than reset lock mode, and effective for purpose to avoid mis-operation when controlled.

Function to output ON/OFF of total 32 units from one master unit. (when master/slave)

It is possible to delay the ON/OFF time, and simultaneous ON/OFF setting is possible as well.

Ideal function for application which require time delay for ON/OFF setting.

Full LOCK Normal LOCK

Lock voltage and current setting dial, and effective for purpose to avoid changing output setting by mistake or when easy emergency stop is required.

3

12

Function to select two different lock functions for two different purpose."Full Lock" locks all the function on front panel, and "Normal Lock" locks all the function except for ON/OFF. "Full Lock" mode shall be good in case mis-operation have to be completely avoided, and

"Normal Lock" mode shall be good in case to avoid mis-operation but secure the way for emergency stop of power supply. You can select the best mode according to your level of "Security", (in both modes, emergency stop is possible with Power Switch.)

* When 115VAC Maximum Output

Press down SETSelect a memorywith 3 buttons

Set voltage andcurrent

OUTPUT ON(From Master)

OUTPUT OFF(From Master)

Up to 32 units

Master

Slave1

Slave2

Slave3

t1 t5

t2 t6

t3 t7

t4 t8

*setting range of t1 to t8 is 0.0s to 99.9s

LINEUP

MULTI SETTING FUNCTION

TWO MODE LOCK FUNCTION

DELAY TRIGGER FUNCTION

Memory a

Memory b

Memory c

MODELOutput voltage(V)

Output current(A)

Output Power(W)

Ripple

(mVrms) (mArms)Temperature coefficient(ppm/°C)

CV CC

±200

0 to 10 RK-80L 5 100 to 16

0 to 5 RK-80 5 50 to 36

0 to 1.3 RK-80M80

10 20 to 110

0 to 0.5 RK-80H 20 10 to 320

±10085 to 264VAC50/60Hz 1Ø 0.9kg1A 0.5A 99%

*

Input Voltage Input Current (typ) Power factor (typ)Weight(typ)

AC Input

*

*Master/Slave function is available on the model with -LGmb option.

AC in115V

AC in230V

Page 4: Ultra Slim DC Power Supplies - Matsusada Precision Inc.matsusada.com/dc/rk80/RK80.pdffor purpose to avoid mis-operation when controlled. Function to output ON/OFF of total 32 units

04

+S

-S

R

VO IO

Load- +

VL

Compensate the voltage drop (V0-VL) due to resistance of output lead or drop of stability by contact resistance. (maximum 0.5V)

*+S is common. So external control voltage shall be input with +S as reference. Otherwise it can cause failure.

5V

or VCE

REMOTE FUNCTIONS

FUNCTIONS

Remote sensing

Remote switch ON/OFF

Sink current 1mA

Output

ON

OFF

Open collector

VCE 0.4V

VCE 2V

Relay

SHORT

OPEN

+S(common)*

4.88

"(12

4)0.

31"(

8)

OUTPUTOCP

LOCK

SET

OVP/

VCC

A

CV

10.63"(270)0.89"(22.7) 0.16"(4)

1.38"(35)

AC 100V-240V 50/60HzINPUT

-S

--

LS+LS-+S

++

DIMENSIONS inch (mm)

side

front back

Rear panelFront panel

12

6

1

2

3

4

5

13

14

9

7

15

1617

18

19

8

10

11

Output voltage and OVP setting display

Output current and OCP setting display

Remote programming display

Output display

Light up when output voltage/current control in remote mode.

Light up when output is on.

To be used to turn output on/off when local mode as well resetting protection functions.

This has priority over all operations for safety reason.

1

2

Monitor terminal

Constant voltage operation mode display

Constant current operation mode display

PRESET switch

OVP/OCP switch

LOCK switch

OUTPUT voltage·OVP setting dial

OUTPUT current·OCP setting dial

Power ON/OFF switch

LS switch(remote switch)

+Sense

OUTPUT terminal

-Sense

AC inlet

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

3

4

OUTPUT ON/OFF switch

Page 5: Ultra Slim DC Power Supplies - Matsusada Precision Inc.matsusada.com/dc/rk80/RK80.pdffor purpose to avoid mis-operation when controlled. Function to output ON/OFF of total 32 units

05

Output Control

Output Function

Lock Function

Output Display

Protection

Other Functions

CV Mode : By rotary encoder on front panel Setting resolution of output voltage is 1/256 of rated maximum voltage

CC Mode : By rotary encoder on front panel Output current setting accuracy is 1/256 of rated maximum output current. Remote control is option. See OPTION for remote control function.

Wide output range, automatic limit setting at 80W for voltage and current In CV mode output current drop down when output power is more than 84.05W In CC mode output voltage drop down when output power is more than 84.05W

Lock function locks the output voltage and current setting

Voltage : 3-digit digital meter. *Accuracy is ±0.5% FS ±2 digitsCurrent : 3-digit digital meter. *Accuracy is ±0.5% FS ±2 digits(*Accuracy of preset setting is ±1% FS ±2 digits)

Over voltage protection (OVP) : Cut off the output at set value Setting range : appx. 5% to110% of rated maximum voltage Setting : By front panel rotary encoder Reset : By output ON/OFF switch or remote switch (manual control)Over current protection (OCP) : Cut off the output at set value Setting range : appx. 5% to110% of rated maximum current Setting : By front panel rotary encoder Reset : By output ON/OFF switch or remote switch (manual control)Over temperature protection. (OTP) : Cut off output at abnormal inside temperature.Reset(after temperature get down to normal temperature) : Output ON/OFF switch or Remote switch (manual control)Input brownout(ACF).Blackout protection Output is cut off when input voltage decreased. Reset (when normal voltage value or recovery from blackout) Manual recovery by OUTPUT switch or remote switch for blackout protection(re-output protection function). Automatic recovery when blackout protection is canceled.Sense reverse connection

Remote switch ON/OFF (TTL or external relay), Remote sensingDelay trigger: Individual setting of ON delay and OFF delay(0.0 to 99.9sec)Multi setting function: Voltage and current memory "a", "b" and "c" setting in addition to standard voltage and current preset

Operation Temp

Storage Temp

Storage humidity

Isolation voltage

0°C to 40°C

-40°C to +85°C

20% to 80% (non-condensing)

±250V-DC (Positive or Negative terminal grounding)

SPECIFICATION

Split operation

SERIES OPERATION · PARALLEL OPERATION

Vout+-

+-

V1+V2

PS1

V1

PS2

V20V

[caution] Total output voltage is to be up to 250V. Therefore for models with output voltage of over 250V, series operation cannot be conducted. Output current is to be the smallest current of those.

Please keep all the settings of voltage the same. Output current will be the summation of each current.[caution] Please keep OVP level of power supply maximum to prevent any damage.

[caution] In case of +- operation, the remote connector is connected to negative output terminal. So never connect other remote control to the connector.

PS1

PS2

+Vout

-Vout

0V

+-

+-

Series operation

+

-

PS1

PS2

+-

+-

Load

Parallel operation

RK-80 power supply of same model number can be connected in series or parallel to increase output voltage or current.

ACCESSORIES·Input AC cable 2.5m single phase 3pin type(1)·Instruction manual(1)·Ground plate(1)

Ground plate

*For safer operation connect ground plate and output terminal.

Page 6: Ultra Slim DC Power Supplies - Matsusada Precision Inc.matsusada.com/dc/rk80/RK80.pdffor purpose to avoid mis-operation when controlled. Function to output ON/OFF of total 32 units

06

GPIB

USB

Dsub

32 units can beconnected to one CO-G32m.

CO-MET2-9

CO-G32m

RK-80

RK-80

A

A

A

A

A

A

A

Master

Slave

Up to 32

-LUs1 :USB Interface Board *1 *2

Enable digital control via USB

Modular jack

Converter

RS-232CRS-485

CO-MET2-25

CO-MET4-25

OPTION

-LGmb :Digital Interface Board *1 *2

Enable digital control via GPIB/ RS-232C/ RS-485 as well asone control with Master/Slave function.

-LRmf :Remote multi function *1

+CV, CCor*4

One control function *3

via Master/Slave

Output control

Vout . Iout

0 to MAX

R

0 to about 10k 

Vcon . Icon

0 to about 10V

When controlling several RK-80 power supplies via USB, a USB hub will be required between the PC and RK-80 power supplies. GPIB enables

control of up to 14 CO-G32m modules.

+S(common)

Add above L mark to the model number when ordering  {e.g} RK-80-LGmb alphabetical order 

*-LGmb, -LRmf, -LUs1 cannot be ordered together.

*1) Either -LGmb, -LUs1, -LRmf can be selected.

*2) For detailed specification of USB and digital interface, please refer date sheet of CO series.

*3) Delay triger Function when master/slave can be set individually . It is also possible to cancel one control function except for output by changing Remote/Local,       and set voltage and current preset for each unit.

*4) +S is common. So external control voltage shall be input with +S as reference. Otherwise it can cause failure.

*5) Previous model is Metal RS-232C module.

*6) Previous model is Metal RS-485 module.

CO-M cableOne 2 meter cable is provided per unit. Please notify your sales representative if you need a longer cable or additional cables.

Remote control, it operates 3 range switchable mode as follows.

RK-80L

RK-80

RK-80M

RK-80H

High 16V

10V

8V

36V

27V

16V

110V

80V

60V

320V

250V

160V

5A

8A

10A

2.2A

3A

5A

0.7A

1A

1.3A

200mA

300mA

500mA

Middle

Low

High

Middle

Low

High

Middle

Low

High

Middle

Low

model Switch number Range Rated output voltage Rated output current

1

2

3

1

2

3

1

2

3

1

2

3

*5

*6

Page 7: Ultra Slim DC Power Supplies - Matsusada Precision Inc.matsusada.com/dc/rk80/RK80.pdffor purpose to avoid mis-operation when controlled. Function to output ON/OFF of total 32 units

07

AC INPUT CABLE

CABLE TYPE 1CABLE TYPE 3

125V / 10A 250V / 10A

CABLE TYPE 4(standard)

250V / 10A

♦Book stand

♦Binder

♦Rack mount holder

For one unit operation...

For the applications which require 2 to 6 units combination. Dual, triple and quad multiple operation is possible.

*Cooling fan is needed for more than 3 units combination.

Various accessories are available for convenient use of the unit.

RK-80 series Accessory Kit

*Power supply is not included in the accessories.

10 Units/1 rack holder, and can be placed in a cabinet. Easy to take one unit out.Best suitable for a system operation.With fan unit.

Page 8: Ultra Slim DC Power Supplies - Matsusada Precision Inc.matsusada.com/dc/rk80/RK80.pdffor purpose to avoid mis-operation when controlled. Function to output ON/OFF of total 32 units

1117-01A

Customer Inquiry Sheet (RK-80 series)Please copy this page and fax to above fax number after filling out form below.

USA/canada : 1-888-652-8651other countries : 1-81-75-229-6366FAX

2570 N.First Street Suite 200 San Jose, CA 9513180 Orville Drive Suite 100 Bohemia, NY 11716 5430 LBJ Freeway, Suite 1200 Dallas, TX 75240   Kyoto-City, Kyoto Japan

Tel: +1-408-273-4573 Fax: +1-408-273-4673Tel: +1-631-244-1407 Fax: +1-631-244-1496Tel: +1-972-663-9336 Fax: +1-972-663-9337Tel: +81-75-229-6355 Fax: +81-75-229-6366

San Jose Office : New York Office :Dal las Of f ice : International Office :

www.matsusada.com/contactwww.matsusada.com/productFor products For contact

Headquarters : 745 Aoji-cho Kusatsu Shiga 525-0041 Japan Tel: +81-77-561-2111 Fax: +81-77-561-2113

<option>

-LGmb (GPIB,RS-232C,RS-485) -LUs1(USB I/F)

What product are you interested in?

a quotation

RK-80 RK-80M RK-80HRK-80L

-LRmf(analog I/F)

an explanation of product

introducing one applying for budget

interested in other ( )

a demonstration

Address: State: Zip:

Company name:

Dept.: Title:

Fax:

Name:

Tel:

E-mail:

I would like...

You are currently

Give us your requirement / comment.

Contact information.