Page 1: UNO-4673A / 4683 · Increased Reliability of Power Networks ... Upgrade Aging T&D Equipments ... IEC 61000-4-2 ESD Contact : 8KV Air :15KV Contact : 4KV Air :8KV IEC 61000-4-3 RS

UNO-4673A / 4683 Enabling Smart Grids through Substation

Automation PCs with Domain I/O Expansion

Page 2: UNO-4673A / 4683 · Increased Reliability of Power Networks ... Upgrade Aging T&D Equipments ... IEC 61000-4-2 ESD Contact : 8KV Air :15KV Contact : 4KV Air :8KV IEC 61000-4-3 RS

Why Smart Grid ?

Increased Reliability of Power Networks – Avoid blackouts/brownouts

– Faster rerouting, reclosing

– Learn about problems faster

– Avoid uncontrolled load shedding

Integrate Renewable Energy

– Avoid distributed energy generators – wind, solar, micro & gensets

Increase Energy Efficiency – Energy saving

– Variable-speed drives

– Price-driven demand response

– Enable future apps – eV, V2G

Page 3: UNO-4673A / 4683 · Increased Reliability of Power Networks ... Upgrade Aging T&D Equipments ... IEC 61000-4-2 ESD Contact : 8KV Air :15KV Contact : 4KV Air :8KV IEC 61000-4-3 RS

Enabling the Smart Grid

Self-healing System Renewable Energy

Integration

Micro Grid Management

Demand / Response

Instant Price

Electricity

Market

Smart Substation

Page 4: UNO-4673A / 4683 · Increased Reliability of Power Networks ... Upgrade Aging T&D Equipments ... IEC 61000-4-2 ESD Contact : 8KV Air :15KV Contact : 4KV Air :8KV IEC 61000-4-3 RS

Global T&D Market Trends & Potential

1. Challenges and Trends of Global T & D - Global T & D Infrastructure is aging after World War II

(ex. Over 75% US asset are more than 25 years old)

- Emerging Country’s Urbanization boosting electricity demands

(ex. 350 million population will be added to China urban by 2025)

- Traditional T & D systems will migrate to meet Digitization technology

(Substation automation requirement, ex. IEC61850)

- Renewable Energy(DER) are installed for power generation

(ex. wind energy take 20% share of US electricity by 2030, EU 20% by 2020)

2. Global Market Potential

- 1.5 ~ 2.0 Trillion USD investment at US T & D by 2030

- China’s Electricity Consumption will exceed US by 2030

- China: 58% T & D Growth Y2007 – Y2012

- U.S. : 33% T & D Growth Y2007 – Y2012

- EU : 25% T & D Growth Y2007 – Y2012

- India: 133% T & D Growth Y2007 – Y2012

Page 5: UNO-4673A / 4683 · Increased Reliability of Power Networks ... Upgrade Aging T&D Equipments ... IEC 61000-4-2 ESD Contact : 8KV Air :15KV Contact : 4KV Air :8KV IEC 61000-4-3 RS

T&D Market Potential & Trends

Annual T & D Infrastructure Requirement

Source from OECD 2008 Source from EEI

(B EURO)

Source from AREVA

(B USD)

Page 6: UNO-4673A / 4683 · Increased Reliability of Power Networks ... Upgrade Aging T&D Equipments ... IEC 61000-4-2 ESD Contact : 8KV Air :15KV Contact : 4KV Air :8KV IEC 61000-4-3 RS

Key Subjects of Smart Substations (T&D)

Transmission

Distribution

AMI/AMR

Home/Building Automation

E-Vehicle

Two-way Communication

Ethernet Backbone

Upgrade Aging T&D Equipments

Remote Management

Increased Safety and Security

Intelligent Infrastructure

Use IEC 61850 Standard

Page 7: UNO-4673A / 4683 · Increased Reliability of Power Networks ... Upgrade Aging T&D Equipments ... IEC 61000-4-2 ESD Contact : 8KV Air :15KV Contact : 4KV Air :8KV IEC 61000-4-3 RS

UNO Energy Products

Pe

rform

ance

Price

UNO-4673A 6xLAN, 2xCOM 3xExpansion

UNOP-1624D IRIG-B ( TTL, Fiber, Serial) w/ Auto mode

UNOP-1628D 8 x Iso. COM RS-232/422/485

UNOP-1514C 100Base-FX, SC type w/ Teaming

UNO-P154 Smart LAN IRIG-B ( Fiber, Serial) 100Base-FX, SC type

UNO-P166 IRIG-B ( TTL, Serial) 6 x Iso. COM

UNO-4678 3xLAN, 8xCOM PCI/104

UNO-4671A 6xLAN, 10xCOM PCI-104

UNO-4672 6xLAN, 10xCOM PCI-104

UNO-4683 6xLAN, 2xCOM 3xExpansion

Page 8: UNO-4673A / 4683 · Increased Reliability of Power Networks ... Upgrade Aging T&D Equipments ... IEC 61000-4-2 ESD Contact : 8KV Air :15KV Contact : 4KV Air :8KV IEC 61000-4-3 RS

Ref. Function IEC 61850-3 Normal (req. of CE/FCC)

IEC 61000-4-2 ESD Contact : 8KV

Air :15KV

Contact : 4KV

Air :8KV

IEC 61000-4-3 RS 35 V/m 10 V/m

IEC 61000-4-4 EFT 4KV 2KV

IEC 61000-4-5 Surge 4KV 0.5KV

IEC 61850-3 Standard Overview

IEC 61850 is a Breakthrough for Substation

Automation

– One world, One technology, One Standard

It defines communication protocols in a modern

substation.

IEC 61850-3 defines the general requirements :

Page 9: UNO-4673A / 4683 · Increased Reliability of Power Networks ... Upgrade Aging T&D Equipments ... IEC 61000-4-2 ESD Contact : 8KV Air :15KV Contact : 4KV Air :8KV IEC 61000-4-3 RS

IRIG-B Function Overview

IRIG, Inter-range instrumentation group time codes

Interfaces usually used :

– Fiber optics

– Coaxial lines (TTL)

– RS-485 (Differential)

Auto-mode :

– While the regular IRIG-B source is down, 1st tier devices can be backed up to provide the internal time source.

Page 10: UNO-4673A / 4683 · Increased Reliability of Power Networks ... Upgrade Aging T&D Equipments ... IEC 61000-4-2 ESD Contact : 8KV Air :15KV Contact : 4KV Air :8KV IEC 61000-4-3 RS

UNO-4673A/4683

The New P&E

Rack19’’ 2U Embedded PC Generation

Page 11: UNO-4673A / 4683 · Increased Reliability of Power Networks ... Upgrade Aging T&D Equipments ... IEC 61000-4-2 ESD Contact : 8KV Air :15KV Contact : 4KV Air :8KV IEC 61000-4-3 RS

IEC 61850-3 Certified UNO for Power Substations:

UNO-4673A/4683

Certification: IEC-61850-3 Isolation Power

- AC/DC: 110~220V Modular Design x3 (Module 1 supports PCIe Signal) System

- ATOM D510 1.66GHz / Core i7 - 2GB RAM / 4G RAM - CF: 1 x internal CF slot - HDD: SATA bracket - 6x USB 2.0 (2 x front, 1 x internal, 3 x rear ) - Battery backup SRAM: 1 MB - Temperature: -20 ~ 70°C (IEC 60068-2-2 with 100% CPU/ I/O loading, 48 hrs )

I/O Interface - 2 x isolation serial port Ethernet - 2 x GbE, 4 x 10/100 Display :

- VGA (UNO-4673A) - DVI-I (UNO-4683)

Page 12: UNO-4673A / 4683 · Increased Reliability of Power Networks ... Upgrade Aging T&D Equipments ... IEC 61000-4-2 ESD Contact : 8KV Air :15KV Contact : 4KV Air :8KV IEC 61000-4-3 RS

I/O Modules for UNO-4673A/4683

Standard Expansion

• UNOP-1000I • PCI slot (PCI 2.2)

• Min PCI Card Slot

• UNOP-1000J • Mini PCIe Card Slot

• PCI-104

UNOP-1514C

• LAN 100Base-FX

• Distance: Up to 2 km

• IEEE 802.3, 802.3u, 802.3x

• Wavelength: 1310 nm

• 4 x SC type Multi-mode Fiber

UNOP-1624D

• 4 x iso. COM (DB9)

• Isolation 2000 VDC

• EFT protection 4000 VDC

• Automatic RS-485 Data Flow Control

• IRIG-B (via RS-485, Fiber)

UNOP-1628D

• 8 x iso. COM (DB9)

• Isolation 2500 VDC

• EFT protection 2500 VDC

• Automatic RS-485 Data Flow Control

Page 13: UNO-4673A / 4683 · Increased Reliability of Power Networks ... Upgrade Aging T&D Equipments ... IEC 61000-4-2 ESD Contact : 8KV Air :15KV Contact : 4KV Air :8KV IEC 61000-4-3 RS

System Architecture/ Substation Automation

Page 14: UNO-4673A / 4683 · Increased Reliability of Power Networks ... Upgrade Aging T&D Equipments ... IEC 61000-4-2 ESD Contact : 8KV Air :15KV Contact : 4KV Air :8KV IEC 61000-4-3 RS

HMI/SCADA Application in Substation

• Application Requirements:

- Reliable IEC 61850-3 platform

- Redundancy

• Solution & Features: - UNO-4673A/UNO-4683: IEC 61850-3 platform

- UNOP-1624D: IRIG-B (TTL, Fiber, Serial) with

auto mode

FPM Series

Product Offering

UNO-4683

110/220 AC/DC & 48VDC

3 x Expansion Slots

UNO-4673A

110/220 AC/DC & 48 VDC

3 x Expansion Slots

UNOP-1624D

IRIG-B (TTL, Fiber, Serial)

w/ Auto mode

Page 15: UNO-4673A / 4683 · Increased Reliability of Power Networks ... Upgrade Aging T&D Equipments ... IEC 61000-4-2 ESD Contact : 8KV Air :15KV Contact : 4KV Air :8KV IEC 61000-4-3 RS

Cyber Security for Smart Grids

• Application Requirements:

- Reliable IEC 61850-3 platform

- Fiber optic LAN

• Solution & Features: - UNO-4673A/UNO-4683: IEC 61850-3 platform

- UNOP-1514C: 100Base-FX, SC type w/ teaming

Product Offering

UNO-4673A

110/220 AC/DC & 48 VDC

3 x Expansion Slots

UNOP-1514C

100Base-FX, SC type

w/ Teaming

UNO-4672

110/220 AC/DC

LAN Redundancy (Teaming)

Page 16: UNO-4673A / 4683 · Increased Reliability of Power Networks ... Upgrade Aging T&D Equipments ... IEC 61000-4-2 ESD Contact : 8KV Air :15KV Contact : 4KV Air :8KV IEC 61000-4-3 RS

Network Recorder and Analyzer

• Application Requirements:

- Reliable IEC 61850-3 platform

- High Speed Computing & Packet Acquisition

- Synchronized Time Stamp

- RAID for storage

• Solution & Features: - UNO-4672: IEC 61850-3 platform

- UNO-P154: Smart LAN 100Base-FX, SC type

Product Offering

UNO-4672-D

110/220 AC/DC

LAN Redundancy (Teaming)

UNO-P154

Smart LAN

IRIG-B (Fiber, Serial)

100Base-FX, SC type

UNO-4683

110/220 AC/DC & 48VDC

3 x Expansion Slots

UNOP-1584C

Smart LAN

100Base-FX, SC type

Under

Planning

Page 17: UNO-4673A / 4683 · Increased Reliability of Power Networks ... Upgrade Aging T&D Equipments ... IEC 61000-4-2 ESD Contact : 8KV Air :15KV Contact : 4KV Air :8KV IEC 61000-4-3 RS

Data Gateway for IEC-61850

• Application Requirements: - Reliable IEC 61850-3 platform

- Isolated COM port

- IRIG-B Time Sync. Receiver

- Fiber optic LAN

• Solution & Features: - UNO-4673: IEC 61850-3 platform

- UNOP-1628D: 8 x Iso. COM RS-232/422/485

- UNOP-1624D: IRIG-B (TTL, Fiber, Serial) with auto

mode

- UNOP-1514C: 100Base-FX, SC type w/ Teaming Product Offering

UNO-4673A

110/220 AC/DC & 48 VDC

3 x Expansion Slots

UNOP-1624D

IRIG-B (TTL, Fiber, Serial)

w/ Auto mode

UNOP-1628D

8 x Iso. COM

RS-232/422/485

UNOP-1514C

100Base-FX, SC type

w/ Teaming

Page 18: UNO-4673A / 4683 · Increased Reliability of Power Networks ... Upgrade Aging T&D Equipments ... IEC 61000-4-2 ESD Contact : 8KV Air :15KV Contact : 4KV Air :8KV IEC 61000-4-3 RS

Lots of Opportunities…

Metallurgy Petro chemistry Aluminum

Besides

Power Generation

Noticeable Heavy Industry

Page 19: UNO-4673A / 4683 · Increased Reliability of Power Networks ... Upgrade Aging T&D Equipments ... IEC 61000-4-2 ESD Contact : 8KV Air :15KV Contact : 4KV Air :8KV IEC 61000-4-3 RS

Thank You