us-big ship industrial shipping scale instructions manual | usbalance -
TRANSCRIPT
8/6/2019 US-BIG SHIP Industrial Shipping scale Instructions Manual | USBALANCE -
http://slidepdf.com/reader/full/us-big-ship-industrial-shipping-scale-instructions-manual-usbalance- 1/4
8/6/2019 US-BIG SHIP Industrial Shipping scale Instructions Manual | USBALANCE -
http://slidepdf.com/reader/full/us-big-ship-industrial-shipping-scale-instructions-manual-usbalance- 2/4
8/6/2019 US-BIG SHIP Industrial Shipping scale Instructions Manual | USBALANCE -
http://slidepdf.com/reader/full/us-big-ship-industrial-shipping-scale-instructions-manual-usbalance- 3/4
3
DISPLAY :
HOLD FUNCTION
1) Place the item on the scale platform.
2) Wait for the weights to be displayed.3) Press the hold key. The “.“ hold indicator will turn-on.
4) Remove the item from the scale platform. The item’s weight reading will
remain on the display. You can now also convert this to other measures (ie toPounds or Kilograms) by pressing the [UNIT] key.
5) Quit hold function: Once an item is weighed and the hold function isenabled; you want to quit to hold function, Press the hold key again to cancel
the “.“ hold indicator and return the scale to weight mode.
Before weighing
WEIGHING
Whenever possible, please allow the scale to warm up for several secondsafter first turning the power on so that the scale will function properly and
accurately.
Error messages
EEEE: overload: Low battery
Weighing Procedures
1. Press [ON/OFF] to turn on the scale.When the power is turned on, all display segments appear for a fewseconds and “O” will appear on the display.
2. Select the weighing unit with [UNIT].Press [UNIT] to select a weighing unit “kg”, “lb”.Once the unit has been selected, the selected unit will be displayed
next to the weight value.
3. Start weighingif you do not use a container for weighing,Verify the reading is “O”. If not, press [ZEROI to display “0”.
Place the items to be weighed on the platform.
If you use a container for weighing,Place an empty container on the platform.
Wait for the stability weighing to be displayed and press [ZERO]
Place the objects to be weighed in the container.
1. Enter function setting mode.
FUNCTION SETTINGS: Press [ON/OFF] to turn the power off, Press [HOLD] first, and then press
[ON/OFF], while keeping [HOLD] pressed, the display will show A_OFF.
2. Selection of auto shut off mode.When the scale enters function setting menu the display will show A_OFF.
Press [ZERO] to choose ON or OFF: selection display ON, this means auto
Shut off function active. Press [ZERO] again, the display will show OFF,
this means that auto shut off function is inactive.
3. Selection of auto backlight mode.
ZERO1.0.0.0.0
Low battery indicator
Negative value Indicator
Kg
Lb
Weighing Unit
Hold IndicatorZERO indicator
Indicates when the reading is 0
8/6/2019 US-BIG SHIP Industrial Shipping scale Instructions Manual | USBALANCE -
http://slidepdf.com/reader/full/us-big-ship-industrial-shipping-scale-instructions-manual-usbalance- 4/4
4
When the scale enter function setting menu, Press [HOLD] key, the display
will show L-ON (or OFF), press [ZERO] to choose ON or OFF: selection
display ON, this means auto backlight function active, press [ZERO] again,
the display will show OFF, this means auto backlight function inactive, i.e.
shut off backlight function.
4. Return to weighing mode.Press [ON/OFF] to turn the power off, press [ON/OFF] again to turn on the
power and the scale return to the weighing mode.
CALIBPATION
When to calibrate ? - Calibration is almost never required.If the scale is inaccurate, calibration may be desired when the scale is first set
up for use, or if the scale is moved to a different altitude or gravitation. This
is necessary because the weight of a mass in one location is not necessarily
the same in another location also, with time and use, mechanical deviations
can occur.
How to calibrate
Note: calibration value must be more 2/3 of the capacity value that you
have set.
1. Press and keep [ZERO] key then turn on the scale, the display will show
CXXXXkg
2. Press [UNlT] key to select setting unit between kg and lb, press [HOLD]
key to move flash digit to right, press [ZERO] key to increase flash digit..
Press [TARE] key, the display will show CAL then AD value. Press [UNIT]
key, the display will show flashed calibration weight. Place the shown weight
then press [UNIT] key, the display will show then AD value. Take off
the calibration weight then turn off the scale.. Calibration finished.If calibration is repeatedly incorrect then: 1) Replace the batteries, 2) Try a
more stable surface or vibration and interference free location.
SPECIFICATIONS
Model number Capacity
Division
US-BIG-SHIP 400lb 0.1lb
Platter /Tray 14’ x16’/355x405mm
Net/gross
weight
4.5kg/5.5kg
Package Standard carton : 530x470x130
(mm3)
Operating
Temperature
Optimum : 15-30C (62-90f)
Power source 6 x AA Batteries or AC/DC
Adapter 9~12V/100mA (selectable)
• Auto shut off (selectable)
FEATURES
• Auto zero tracking
• Large LCD
• Large square weighing tray• Kg Lb optional
• Auto calibration
• AC power (selectable)
• Hold function
• Auto Backlight (selectable)
SPECIAL WARNING
All phones, Cordless-Phones, and any radio-frequency device can
cause temporary interference and cause the scale to temporarily notwork properly. Please do not use any electronic device near the
shipping scale. Just like in an airplane, do not use your cell-phone near
the scale when it is in use. While there is NO risk of permanent
damage to the scale, interference can cause an incorrect cal ibration or
incorrect weight readings.