venue and technical information - aeglive-clubnokia.s3...
TRANSCRIPT
VENUE AND TECHNICAL
INFORMATION
MUTEMATH, Photo by Max Roper
OLYMPIC AND FIGUEROA
DOWNTOWN LOS ANGELES March 2016
Version 1.1
JENNIE [email protected]
LENISE STRONG
GENERAL MANAGER MARK GIRTON
ASSISTANT GENERAL MANAGER
PRODUCTION & OPERATIONS
TALENT BUYER JEFF SHUMAN(323) 930-7122
SPECIAL EVENTS COORDINATOR
THE NOVO CONTACT INFORMATION800 WEST OLYMPIC BLVD SUITE A335
LOS ANGELES, CA 90015
MAIN PHONE: 213‐765‐7000
MAIN FAX 213‐765‐7001
MERCHANDISE CONTACT
DIRECTOR OF OPERATIONS
MARKETING MANAGER
323-930-5748
ASSISTANT TO TALENT BUYER DOMINICK PRIETO(323) [email protected]
YESENNIA DE LA TORRE
CHIP SCHULTZ213-765-7002
VIP SALES MANAGER RAIHNI VAUGHN213-765-7004
DIRECTOR OF SALES BAILEY NAKANO
PRODUCTION MANAGER
LIZZ [email protected]
[email protected] MANAGER
WOLFGANG PUCK JAMIE KORTH
BOX OFFICE MANAGER ALEXIS [email protected]
STAGE DIMENSIONS, VENUE MEASUREMENTS, AND WEIGHT RESTRICTIONS
Stage: Width: 38 feet Depth: 30 feet to back wall- approx. 27 feet to upstage curtain Height: 4 feet high from dance floor Downstage edge is in-line with proscenium edge
Wings:
SR Width: 22 feet SR Depth: 26 feet SL Width: 28 feet SL Depth: 26 feet
Proscenium opening:
Width: 38 feet Height: 27 feet to curtain swag Depth 3 feet
Front of house booth:
Width: 17 feet Depth: 10 feet Height of wall: 4 feet
Distances:
From downstage edge to Front of House: 40 feet From downstage edge to spot booth catwalk 101 ft
Various Measurements:
Height from stage to I beams: 44 feet Height from stage to truss at standard trim: 23-26 feet (adjustable) Height from floor to steel in main house: 55’10” Height from floor to ceiling in house: 61’ 7”
Main floor measurements:
Height from back of house to ceiling: 10.5 feet Height from middle section to ceiling: 11 feet Height from front pit to balcony edge: 11.5 feet
Load in door from back hallway to stage (upstage left):
6’10” wide 7’10” tall
Door frames from back of house to main floor of venue: 5’11” wide 6’10” tall 8’11” diagonal
Freight Elevator Dimensions:
Door Width: 9’ 11” Door Height: 10’ 0” Elevator Diagonal Width: 14’ 2” Interior Height 9’8” Elevator Depth: 10’ 11”
Door Frame in loading dock leading to freight elevator:
Door Width 5’ 11” Door Height 7’ 11” 9’ 10” Diagonal
Loading dock load in distances:
Distance from load in bay to freight elevator: 222.10 ft Distance from turnaround space in dock to freight elevator: 322.5 ft Distance from freight elevator stage level to stage left door: 115.9 Ft
Weight Restrictions:
Stage floor: 100lbs psf live load Main venue floor: 50lbs psf live load I beams- 8,500 lbs TOTAL per beam uniformly loaded
Marquee Dimensions:
(2) sides, each is 4.2ft wide x 12.6ft tall Resolution: 10mm 128 pixels wide x 384 pixels tall
TITLE:
DATE:
REVISION:
DRAWN BY:
SCALE:
DRAWING:
PROJECT:
CLIENT:
NOTES:
Stage Dimensions
October 8, 2008
4.0
ES
NTS
O-1
THE
NO
VO
SIZE:B
SHEET:
3OF:
7
1:12RAM
P
1:12RAM
P
38'-0"
30'-0
"
22'-9"
9'-8"
3'-2
"
28'-0"
22'-3
"
33'-9"
4'-0
"
6'-0" 3'-0" 3'-0" 6'-0"
THE NOVO STAGE POWER USR: (2) 400A services- (1) open and available for guest lighting (1) 200A service (house motors are on this service) USL: (1) 100A guest service isolated for audio DSL: (1) 100A service isolated for audio (house audio) All power services are cam lock connections
THE NOVO RIGGING AND SOFTGOODS
Truss and Rigging (4) 45’ Lighting Trusses ((1)-DS of proscenium, (3) On Stage) (1) 54’ Curved FOH Truss (2) 24’ Leg Trusses (1) 14’ Cable Bridge (2) 45’ Traveler Trusses Chain Hoists on All Trusses All Truss Except Upper Bowl Reduction is 20.5” Spigoted Box Truss
All truss hang from I Beams that run upstage/downstage 45 feet apart.
THERE ARE NO CENTER RIGGING POINTS ON STAGE
Soft goods (1) 45’w X 34’h motorized red downstage traveler, variable speed, bi-parted (1) 45’w X 34’h manual black drawn upstage traveler, bi-parted (10) 8’w X 21’5”’h Legs upper bowl reduction curtain on truss and chain hoists
*Any soft goods brought into the building MUST carry a California seal indicating that they have been treated in California and are fireproof
TITLE:
DATE:
REVISION:
DRAWN BY:
SCALE:
DRAWING:
PROJECT:
CLIENT:
NOTES:
Rigging Plot
October 13, 2008
4.1
CN/ES
NTS
R-1
THE
NO
VO
SIZE:B
SHEET:
5OF:
7
Steel Cantilever 24" Steel Cantilever 24"
Exposed Beam for Audio RiggingEL: 71'10" (approx)
Exposed Beam for Audio RiggingEL: 71'10" (approx)
1500Lbs (EL 71'10")
1500Lbs (EL 86'10")
2000Lbs (EL 86'10") 2000Lbs (EL 86'10")
1500Lbs (EL 86'10")
2000LB (EL 91')
2000Lbs (EL 86'10")
2000Lbs (EL 86'10")
2000Lbs (EL 86'10")
2000LB (EL 91') 2000LB (EL 91')
2000LB (EL 91')
2000LB (EL 91')
2000Lbs (EL 86'10")
2000Lbs (EL 86'10")
2000Lbs (EL 86'10")
2000Lbs (EL 71'10")
2000Lbs (EL 71'10")
2000Lbs (EL 71'10")
2000Lbs (EL 71'10")
2000Lbs (EL 71'10")
1500Lbs (EL 71'10")2000Lbs (EL 71'10")
1000LB (EL 91')
1000LB (EL 91')
1000LB (EL 91')
1000LB (EL 91')1250LB (EL 91')
1250LB (EL 91')
1250LB (EL 91')
1250LB (EL 91')
1250LB (EL 91')
1250LB (EL 91')
Legend
Motor Point
20'-6"
11'-8"
31'-3"
45'-8"
All Dimensions +/-1'
TITLE:
DATE:
REVISION:
DRAWN BY:
SCALE:
DRAWING:
PROJECT:
CLIENT:
NOTES:
Truss Locations
October 8, 2008
4.0
CN/ES
NTS
L-2
THE
NO
VO
SIZE:B
SHEET:
2OF:
7
1:12RAM
P
1:12RAM
P
3'-6
"7'
-0"
7'-0
"3'
-0"
5'-0
"
50'-0"
25'-6
"
7'-0
"
16'-0
"
S
S
S
S
SS
S
521
ST 11
509
515
520
522
516
12" Curved Truss, 49'Radius, 138 Degrees
20.5" Curved Truss, 25'Radius, 120 Degrees
24'-0
"
45'-0"
14'-0"
All Truss 20.5" Box Except Where Noted
TITLE:
DATE:
REVISION:
DRAWN BY:
SCALE:
DRAWING:
PROJECT:
CLIENT:
NOTES:
Truss Overview
October 8, 2008
4.0
CN/ES
NTS
R-3
THE
NO
VO
SIZE:B
SHEET:
7OF:
7
40'-0
"
32'-0
"
50'-0
"
27'-0
"
46'-0
"
26'-1
0"
24'-0
"
27'-6
" 33'-0
"
PA FOR ILLUSTRATIONONLY
CABLE BRIDGE
TITLE:
DATE:
REVISION:
DRAWN BY:
SCALE:
DRAWING:
PROJECT:
CLIENT:
NOTES:
Centerline Section
October 8, 2008
4.0
CN/ES
NTS
O-2
THE
NO
VO
SIZE:B
SHEET:
4OF:
7
LIGHTING
Lighting Fixtures
(24) Varilite VL3000 Spots
(12) Varilite VL3500 Washes
(84) ETC Source 4 Pars on Racks of Six
(21) ETC Source 4 Ellipsoidals (6-14°, 9-19°, 9-26°, Spare Barrels: 6-36°, 6-50°)
(22) Martin Atomic 3000 Strobes
(3) four light molefays
(4) Lycian 2500W Medium Throw M2 Followspots with Electronic Ballasts
Control
(2) High End Systems Hog IPC Lighting Consoles (1-Active, 1-Spare) with Full Size
Expansion Wing
(3) 96 Channel Combined Dimmer and Moving Light Distribution Racks (108-
Dimmers, 108 Circuits 208V Total)
(1) House Light Controller at FOH
Miscellaneous
(1) DF50 and Fan
(1) Rosco V Hazer
All Necessary Cable
Spare Lamps
House Gel Package (light inventory, please advance if you need specifics for your
event)
*Please advance any hazing/fogging/smoke with the production manager. The Novo is within
a larger building complex and fire alarm must be disabled prior to any smoke effects. Fire
Marshal is required to be onsite for duration of hazing and additional costs may apply.
26°
26°
26°
26°
26°
26°
26°
26°
26°
36°
36°
36°
36°
36°
36°
Motorized Main Traveller
Manually Drawn Upstage Traveller
Leg Truss c/w 5 Repositionable Legs
Cable Bridge
4 Light Blinder
ETC Source 4 Par Bod
ETC CE Source 4 26°
ETC Source-4 36°
Atomic 3000 Hung
Varilite VL 3500 Wash
Varilite VL 3000 Spot 20
12
20
36° 6
26° 9
84
3
THE NOVO FULL PLOT
Date: 2/12/15File name: THE NOVO Plot.vwx
THE NOVO AUDIO AND VIDEO
Front of house position is 17.1 feet wide x 10 feet deep, and located 40 feet from the downstage edge.
House Sound System: The house system is a JBL Vertec line array system consisting of (2) flown arrays, (4) under stage subs,
(6) subs ground stacked underneath line array, (4) front fill speakers, and (6) delay speakers on the
main level.
Consoles: Both front of house and monitor consoles are Soundcraft Vi6.
Upper Line Array:
(6) JBL Vertec 4888DPAN per side
Flown Subs:
(4) JBL Vertec 4882DPAN per side
Lower Line Array:
(4) JBL Vertec 4888DPAN per side
Understage Subs:
(4) JBL ASB6128V total powered dual 18s
Additional Subs:
(6) JBL SRX728S Dual 18 subs (3 per side ground stacked underneath line array)
Front Fills:
(2) JBL AE6212-64 non-powered
Outfills:
(2) JBL AE6212-64 non-powered
Rear Delay Speakers:
(6) JBL VRX-932LA
Stage Monitor System: The stage monitor system is a Clair Brothers rig with 12 wedges, a drum fill and 2 side fills- 8 total
mixes.
Stage:
(12)Claire 12AM wedge
(7)Crown IT-4000
Drum Monitors:
(1)ML-18 subs
(1) 12AM wedges
(3) Crown IT-4000
Side Fills:
(2) Clair R4 III 3-way speakers (1 per side)
(2) Crown IT-4000
(2) Crown IT-6000
(2) M18 Clair Brothers sub woofers
Mic Split: The venue is equipped with a 60-channel 3-way mic split system. 60 direct lines are fed via the built-in
snake to the FOH position. The first and second mic splits appear on the stage left media panel for use
of the monitor position and any auxiliary recording position desired.
Stage Audio Power: 100 Amps upstage left (guest service)
100 Amps downstage left (house power)
Microphones, stands, and cabling: (12) Shure SM57lc
(6) Shure Beta 98d/s
(4 ) Shure KSM32/sl
(1) Shure Beta 91
(2) Shure Beta 52
(2) E609s Sennheiser silver series
(3) Sennheiser 604 dynamic mics
(8) Shure Beta 58a
(5) KSM109sl
(2) 421 dynamic mics
(2) Shure Beta 57a
(8) J48 active direct boxes
(8) J48 passive direct boxes
(4) Beta 58 wireless mics (2) KSM9 capsules available
(4) short mic stands, tripod w/ boom
(10) straight mic stands
(9) tall boom stands tripod base
(20) medium tripod boom stands
(6) telescoping boom arm black
(25) 10' 20 gauge mic cable with neutrik
(25) 15' 20 gauge mic cable with neutrik
(25) 25' 20 gauge mic cable with neutrik
(3) 50' 20 gauge mic cable with neutrik
Sound Snake Pull: There are (2) 6” conduits from front of house to stage left for audio use. One of the conduits has the
house permanent snake, the 2nd
conduit is available for guests. Snake run is approximately 150ft long.
Recording: (1) Tascam DV-RA1000HD high definition CD recorder
Clear-Com Intercom: The Novo is powered by a 4-channel Clear com intercom system. Every Media Panel has all 4
channels present on xlr pins for easy assignment of belt packs.
(1) Base station MS-704
(10) Single Channel belt packs RS-601
(10) Single muff Clear-Com headsets
Media Panels: There are 5 media panels in the club as follows:
MP-901 Stage Left
(24) audio lines to the patch room
(8) video lines to patch room
(4) cat5 lines to patch room
(2) DMX lines to patch room
(6) single mode fiber lines to patch room
(6) multi mode fiber lines to patch room
(12) audio tie lines to stage right media panel
(4) video tie lines to stage right media panel
(60) mic splits on XLRS
(60) Mic splits on DT-12 connectors
(4) channels of intercom
MP-902 Stage right
(12) mic line inputs on DT12s and XLRS (mic inputs 49-60)
(4)cat5s to patch room
(2) DMX lines to patch room
(8) audio lines to patch room
(8) video lines to patch room
(4) channels of intercom
(6) single mode fiber to patch room
(6) multi-mode fiber to patch room
(1) 25-pair cat3 to patch room
MP-903 Upstage Center media Panel
(48) mic lines 1-48 on DT 12 connectors
(12) mic lines 37-48 on XLR connectors
(6)cat5s to patch room
(2) DMX lines to patch room
(8) audio lines to patch room
(8) video lines to patch room
(4) channels of intercom
(6) single mode fiber to patch room
(6) multi-mode fiber to patch room
(1) 25-pair cat3 to patch room
MP-904 FOH Media Panel
(4) cat5s to patch room
(2) DMX lines to patch room
(14) audio lines to patch room
(8) video lines to patch room
(4) channels of intercom
(6) single mode fiber to patch room
(6) multi-mode fiber to patch room
MP-906 Catwalk
(8) cat5s to patch room
(2) DMX lines to patch room
(8) audio lines to patch room
(10) video lines to patch room
(4) channels of intercom
(6) single mode fiber to patch room
(6) multi-mode fiber to patch room
(1) cat3 25-pair
Video Production: The Novo is pre-wired for a 3 camera image-magnification system as well as capabilities for broadcast
cameras from all major areas. The stage right patch room has a video switcher to allow choosing
between in-house cameras, Blu Ray player, in-house digital signage system or other auxiliary feeds
from any media panel.
All (4) dressing room have a 42” plasma TV with an individual Direct TV receiver, and the ability to
watch the house program show feed.
The entire system is 1080i HD system, 16x9 aspect ratio. There is some conversion ability from other
formats but the main distribution system is all HD-SDI.
Cameras: (3) Sony BRC-H700 robotic HD cameras
Switcher: (1) Datavideo SE-1000A switcher
Playback options: (1) Sony Blu Ray player, can play standard DVDs
Venue Televisions: Ground Floor Screens:
(2) 65” Panasonic Plasma right and left of the proscenium
(4) 42” plasma TVs
Balcony Screens:
(3) 65” Panasonic Plasmas
VIP Room Screens
(8) 42” plasma TVs
5th
Floor (3rd
floor of venue, behind the balcony)
(1) 42” plasma TV
Content can easily be displayed either by DVD or Blu Ray loop or JPEG images sized 1364x768 can
be uploaded onto our media server for display.
THE NOVO DRESSING ROOMS The Novo has (4) large dressing rooms, each with their own private ADA accessible bathroom and shower. Each room can comfortably hold 6-8 people. Each room has a full length mirror, a long vanity station, a refrigerator, couches and armchairs. Each room has a closet with a garment bar to hang clothing. There are (2) dressing rooms stage level and (2) dressing rooms one level above stage. The upstairs dressing rooms can be accessed either by stairs or elevator. Direct TV, show feed, and Wi-Fi are available in each room. There is a green room/catering area one level above stage which holds up to 30 people. This room does not have any restroom facilities.
LOADING DOCK DIRECTIONS 1015 Chick Hearn Court Los Angeles, CA 90015
*PLEASE NOTE* Please advance arrival times and any pre-load in parking needs with the production
manager. Access to the loading dock is by pre-approved appointment only. Any unscheduled truck or vehicle
may be subject to refusal or extended wait times.
The Novo is located on Figueroa Boulevard between Olympic and 11th
street, across the plaza from the
Microsoft Theatre.
The loading dock has (3) bays with levelers and turn around space for small vehicles. Load in is,
however, typically ONE VEHICLE AT A TIME due to high traffic in the loading dock during normal
business hours. Trucks cannot live in the dock, and parking must be coordinated in advance for any vehicles
staying on site. There is a push from the loading dock to a freight elevator, up to the 3rd
floor, and a push from
the elevator to stage left.
The loading dock entrance is marked as GATE D at the corner of Chick Hearn and LA Live Way.
Driving Directions to The Novo Loading Dock:
101 Fwy southbound from San Fernando/Santa Clarita Valleys to
110 Fwy southbound (Harbor Fwy/San Pedro) from Burbank, Glendale, Pasadena
110 Fwy southbound
exit Olympic Blvd. and turn left at end of ramp
at 11th
Street turn left
continue on 11th
Street just past LA LiveWay
turn left into the first driveway after LA LiveWay and check in with guard
10 Fwy westbound from San Bernardino, Riverside, Pomona, Ontario, etc.
10 Fwy westbound (towards Los Angeles)
110 Fwy northbound exit then take the Pico Blvd. off ramp
continue north past Pico Blvd. (on Cherry St.) to 11th
Street
at 11th
Street turn right
turn left into the first driveway after LA LiveWay and check in with guard
405 Fwy southbound from Thousand Oaks, Simi Valley, etc. to
10 Fwy eastbound from Westside
10 Fwy eastbound
exit Hoover St., turn left and continue to Alvarado St.
turn right at Pico Blvd.
continue on Pico Blvd. to Cherry Street
at Cherry Street turn left to 11th
Street
at 11th
Street/Chick Hearn Ct. turn right
turn left into the first driveway after LA Live Way Street and check in with guard
405 Fwy northbound from San Diego, Orange County, Anaheim, etc.
405 Fwy north to 110 Fwy north (Harbor Fwy/Los Angeles)
take 110 Fwy north and transition to the 10 Fwy West
take the Pico Blvd. off ramp
continue north past Pico Blvd. (on Cherry St.) to 11th
Street
at 11th
Street/Chick Hearn Ct turn right
turn left into the first driveway after LA Live Way and check in with guard
THE NOVO PARKING INFORMATION
Bus and truck parking are per advance and assignments are typically given out one week prior to show. There is no ‘onsite’ parking. The various assigned lots are typically across or down the street from the venue and are dictated by LA Live parking based upon availability. Detailed instructions are sent prior to load in with corresponding maps and directions. While we make every effort to arrange for free parking that is nearby, there is often a charge associate with parking large vehicles. At times, available parking may be a couple of blocks away. As is the case in most large cities, parking is extremely limited around L.A. Live. Artists in individual cars can be accommodated in the East Parking Garage. There are 6 reserved spaces per event. Additional car parking above the 6 spaces may result in additional charges. All parking directions are per advance and are subject to change.
110
10
Lot 8
Lot 4
Lot 5
Lot 13
Lot 10
Wood Bl.
James M.
Lot 12Garage
Lot 9
9th St.
Olympic Bl.
Venice Bl.
Gilbert Lindsay
Plaza
PEDESTRIAN WALKWAY
11th St.
Chick Hearn Ct.
12th St.
Blue &Expo Line
(Pico Station)Convention Center
West Hall Parking
Convention CenterSouth Hall Parking
Santa Monica Freeway
Figu
eroa
St.
BondLot
Lot E(underground lot)
Lot W
West Garage
Lot W
Lot 1 Garage
Lot C South
Venice Garage
SWVIP
Red, Purple, Blue & Expo Line(7th St/Metro Center Station)8th Pl.
Fran
cisco
St.
Geor
gia S
t.
Blain
e St.
Gate B
Gate D Gate C
Gate E
Gate G
Gate F
Gate HWest Rd.
11th St.
12th St.
9th St.
11th Pl.
12th Pl.
NNHa
rbor
Free
way
Pico Bl.
Flow
er S
t.
Hope
St.
Lot C North L.
A. L
ive W
ay
BlaineA
BlaineB
Parking Lot Entrances
Timed Parking LotsL.A. LIVE / STAPLES Center Lots - Flat rate, Pass lots
Convention Center Lots - Flat rate
Restricted Access
Private Lots - Flat rate
Pick-up / Drop-off for Taxi, Bus, LimoElectric Vehicle Charging Stations
THE NOVO VIP LOUNGE
The Novo has a large VIP lounge that can accommodate up to 350 people. This room is typically open to venue, industry, and artists’ guests before, during, and after the event (*subject to change at any time). It has a cash bar and private cabanas that may be reserved upon advance request. If you would like to arrange an after-show party in the VIP room, please contact the production manager to coordinate any hospitality needs and secure space.