victron products - gylling teknikk as · victron products chargers / powersuply’s inverter /...

44
Victron Products Chargers / Powersuply’s Inverter / Multies Isolation transformers DC / DC converters Panels / battery monitors Battery isolators / batytery’s Solar products

Upload: vanminh

Post on 14-Jul-2018

225 views

Category:

Documents


0 download

TRANSCRIPT

Victron Products

Chargers / Powersuply’s

Inverter / Multies

Isolation transformers

DC / DC converters

Panels / battery monitors

Battery isolators / batytery’s

Solar products

Chargers

12 / 24 / 48 VDC

Must is multi voltage 90 to 265VAC

Must can run on DC voltage 90 to 400VDC

Must can be used as power suply

Multi outputs

Some have voltage / temp. sensor

GMDSS Charger

Small units

Big units

Inverters

Inverters from 12VDC , 24VDC and 48VDC to 230VAC and 400VAC

Inverters from 12VDC and 24VDC to 120VAC 60Hz.

All inverters have pure sinewave.

All inverters have extra start up power.

All have possibility for remote control.

All VE-Bus units can be parallel and 3 phase up to 30 units.

Programable relay used by VE.Cof. Software (build in)

From 180VA to 5KVA.

Inverters

Multis and Quattros

Same features as inverters but also :

Powerfull charger 16A to 220A.

Power controll.

Power assistent.

Used with solar system both Grid and Off Grid.

Big Multis have 2 outputs (1 break and 1 No-break).

Quattros have 2 in-put and 2 out-put.

2 in-put gives a intergrated transfer switch.

From 800VA to 10KVA

Transfer switch from 16A to 100A

Multi and Quattro

AC POWER MANAGEMENT

Primary supply

(generator or shore)

Supply to on board

consumers

Energy converted

to charge batteriesUnder normal conditions,

there is sufficient power to

supply load and charge

batteries.Battery

Phoenix Multi

AC POWER MANAGEMENT

Primary supply

(generator or shore)

Supply to on board

consumers

Less energy

converted to

charge batteries

As demand from on board

consumers increases,

power used to charge

batteries is reducedBattery

Phoenix Multi

AC POWER MANAGEMENT

Primary supply

(generator or shore)

Supply to on board

consumers

Energy drawn

from batteriesWhen demand from

consumers exceeds

capacity of supply, energy

is drawn from battery to

assist shore/generatorBattery

Phoenix Multi

AC POWER MANAGEMENT

Primary supply

(generator or shore)

Supply to on board

consumers

Energy converted

to charge batteriesWhen peak in demand

has reduced, system

returns to normal

operation and the power

used from battery is

replaced.

Battery

Phoenix Multi

MULTIPlus SYSTEM EXAMPLE

Phoenix

MultiPlus

3kVA /

70A

4kVA

generator0.5kVA4kVA

Micro. 1.8kVA

Others 1kVA

Battery

1.5

kVA

Air-Con B 1.5kVA

(5kVA start)

Normal conditions, there is enough power available for

charger to operate at full power.

MULTIPlus SYSTEM EXAMPLE

Phoenix

MultiPlus

3kVA /

70A

4kVA

generator2.8kVA4kVA

Micro 1.8kVA

Others 1kVA

Battery

1.2

kVA

Air-Con B 1.5kVA

(5kVA start)

Consumption by consumers increases so

charger backs off to compensate.

MULTIPlus SYSTEM EXAMPLE

Phoenix

MultiPlus

3kVA /

70A

4kVA

generator

8kVA4kVA

Air-Con B 1.5kVA

(5kVA start)

Micro 1.8kVA

Others 1kVA

Battery

4.0

kVA

When air-con starts, max load may be,

say,8kVA. Multi immediately provides the extra

power required to start compressor.

MULTIPlus SYSTEM EXAMPLE

Phoenix

MultiPlus

3kVA /

70A

4kVA

generator4.3kVA4kVA

Air-Con B 1.5kVA

(5kVA start)

Micro 1.8kVA

Others 1kVA

Battery

0.3

kVA

Once Air-Con. Has started, total load reduces to

4.3kVA, still too much for generator alone.

MULTIPlus SYSTEM EXAMPLE

Phoenix

MultiPlus

3kVA /

70A

4kVA

generator2.5kVA4kVA

Micro. 1.8kVA

Others 1kVA

Battery

1.5

kVA

Air-Con B 1.5kVA

(5kVA start)

Some consumers are switched off and system

returns to normal. Charger re charge what was

taken from the battery.

Other products

Isolations transformers

Auto transformer (for US use 240VAC splitphase)

DC-DC converters non isolated and galvanic isolated.

Automatis transfer switches.

Batteri monitors.

System manager E-plex and system panels

Global remote

Battery isolators.

Battery protection

Shore power cables

Alternators and batteries.

Isolation transformers

DC/DC converters

Transfer switches

Battery monitors

System panels

Global remote

GSM network

Schematic Overview

System state: inverter

Alarms: none.

Warnings: Low Battery.

Battery: 22.35V

122.11A

In: 0.00V 0.00A 0.00Hz

Out: 230.47V 10.42A

49.89Hz

SMS

GPRS

http://www.victronenergy.com/

Later the VGR will be able to start/stop also gensets , first system test are conducted on location

Global remote

All essential information is shown in values and in a graph

•State of the system•All information on Voltage and

Current ( AC and DC )

•When a battery monitor is connected the SOC will be shown

•http://vrm.victronenergy.com/beurs.php

Battery isolators

Battery protect/alternators

Battery’s / shore cables

Solar products

Solar panels

Solar charge controllers

Solar switch

Solar products

New in 2010/2011

Main systems will be with NMEA2000.

New design on units will start in 2010 on Multi serie.

Bigger Quattros 12/5000 , 24/8000 , 48/10000 will be ready.

New Lynx DC distributions system (1000A).

Global remote IO-extender (2 digital output and 3 digital input).

New generation of control panels.

Units will be IP22 in the new design.

Lynx

New generation control panels

New Skylla range

New Skylla range