Page 1: VIDEO DOOR PHONE KIT 3.5”/7” 1 Fam./2 Fam./ 3 Fam. EN User ... · Door open: Ulock = 0Vd.c./max. 10 sec. (point 3) SWC1/SWC2 – Connection of EXIT button (mounted inside the

ENVIDEO DOOR PHONE KIT 3.5”/7”1 Fam./2 Fam./ 3 Fam.User manual

4 wires

Page 2: VIDEO DOOR PHONE KIT 3.5”/7” 1 Fam./2 Fam./ 3 Fam. EN User ... · Door open: Ulock = 0Vd.c./max. 10 sec. (point 3) SWC1/SWC2 – Connection of EXIT button (mounted inside the

KIT INSTALLATION. Follow the steps below, in the described order. STEP 1. Read the diagrams in this brochure and the technical manuals of the KIT (VPA, VTx, SCU). STEP 2. Make the electrical connections to the terminals (ATM, VTM, VTA) and then to the VPA outdoor panel. STEP 3. Make the electrical connections of the LC, LA or LS lock to the terminals of the SCU central supply and command unitand, if necessary, the connections to: the EXIT button; AUX additional installations; BAT; Vcam analog video camera. STEP 4. AUTHORIZED PERSONNEL!!! READ THE SAFETY INSTRUCTIONS FROM THE MANUAL OF THE SCU CENTRALSUPPLY UNIT!!! DISCONNECT the fuses and make the L,N, connections to the SCU CONNECT the fuses to thepower network. The , S2 LEDs turn on, and S1 turns on only if the battery (12V/7Ah) is connected. STEP 5.1. PROGRAMMING THE MAIN ENTRANCE PANEL: RFID CARDS/TAGs At the SCU, long press (2-3 sec.) the PROGbutton (point 5). The PROG Red LED turns on Go to the VPA panel from the main entrance and touch each RFID CARD to the (RFID) area for one second. For each programmed RFID CARD/TAG, the panel issues two beeps. Follow the same steps for programming all the RFID CARDS/TAGs, for all the residents of the building. Return to the SCU and short press the PROG button. The Red LED turns off. The main panel keeps address 1, which is set from the factory and is ready to function. STEP 5.2. PROGRAMMING THE ADDITIONAL PANEL: NEW ADDRESS and RFID CARDS/TAGs. If the access in the buildingis made through two entrances, the VPA2 additional panel (point 10) from entrance 2 must be set up with address 2. At SCU 2 long press the PROG button. The PROG Red LED turns on. At the VPA2 panel, long touch the Fam.1 key, thenshort touch the Fam.1 key, twice. The panel confirms the storage of address 2 with two short beeps. Continue programmingthe CARDS/TAGs in the VPA2 panel. Each touch of the CARD/TAG to the area is confirmed by the VPA2 with two beeps. Return to the SCU2 and short press the PROG button. The Red LED turns off. The VPA2 and VPA1 panels are ready tofunction, with all the terminals in the building. STEP 6.1 PROGRAMMING THE ADDRESS OF THE Fam.1 TERMINAL. The terminals keep Address 1, which is set by themanufacturer. STEP 6.2 PROGRAMMING THE ADDRESS OF THE Fam.2, Fam.3 or more TERMINALS. The terminals for Family 2 will have address 2, the terminals for Family 3 will have address 3 and so on for 4, 5 etc. Program the new addresses as follows: At SCU 1 long press (2-3 sec.) the PROG button. The PROG Red LED turns on At the terminals for Family 2, long touch the key. The terminal confirms with one long beep. Short touch the key twice. Two short beeps are issued. The terminal stores address 2. Continue programming address 3 at Family 3 followingthe same steps. Long touch the key and after the long beep, short touch the key three times. Storage is confirmedwith three short beeps. The terminals are ready to function.

RECOMMENDED CABLES (point 1) Maintain the same wire colors for the same connections.

Out of electrical safety reasons, we recommend installing a grounding cable (minimum 1.00 mm – Green/Yellow) from the

panel (VPM) to the central unit (SCU).

1

DETAILED PRODUCT CODES VPA - advanced video outdoor panel; Product codes: Video 1Fam.VPA.1S(F)R02.xxy04; 2Fam.VPA.2S(F)R02.xxy04;

3Fam.VPA.3S(F)R02.xxy04; 5Fam.VPA.5S(F)R02.xxy04 (S= Surface mounting, F= Flush mounting, R= RFID CARD/TAG access)

RFID access CARD/TAG (secured at reading and copying). They are stored and can be deleted from the VPM.

ATM - smart+ audio terminal; Product code: ATM.0S402.xxy04

VTM - smart+ 3.5” video terminal; Product code: VTM.3S402.xxy04

VTM/VTA - smart+/advanced 7” video terminal; Product codes: VTM.7S402.xxy04/ VTA.7S902.xxy04

VCB – Video connection box (1 video input/4 video outputs - 4 Fam.); Product code: VCB.4DN02.xxy04

EN

INSTALLATION INSTRUCTIONS – VIDEO DOOR PHONE KIT

Thank you for choosing the BELLCOME products. We will assist you throughout the entire warranty period. For technical support and assistance you can contact us at ELECTRA Building Communications GmbH +43 1 810 20 99, [email protected].

21) Max. 75 ml 4 x 0.5 mm (H03VV-F4G 0.5) 22) Max. 150 ml 4 x 0.75 mm (H05VV-F4G 0.75)

3) Max. 250 ml UTP cat5e (AWG24) or UTP cat6e (AWG23)

Page 3: VIDEO DOOR PHONE KIT 3.5”/7” 1 Fam./2 Fam./ 3 Fam. EN User ... · Door open: Ulock = 0Vd.c./max. 10 sec. (point 3) SWC1/SWC2 – Connection of EXIT button (mounted inside the

EN

VSB – Video selection box; Product code: VSB.4DN02.xxy04 (4 video inputs/1 video output)

SCU – Central supply unit for 1 Fam; Product code: SCU.VDR02.xxy14 (110-230Vc.a., 50Hz/13.5Vd.c.-2Ad.c.).

Central supply unit for 3 Fam; Product code: SCU.VDR02.xxy34

PSU – Additional supply unit; Product code: PSU.VDR02.xxy04, necessary when, due to various reasons, the supply voltage

(+U, GND) at the hubs of the terminals drops below 12V. See the user manual of the SCU central supply unit.

Vcam – Additional video camera connection, analogic 1Vv-v, PAL

LC1/LC2 – Connection of direct current lock (max.0.6A/12Vd.c.) Door locked: Ulock = 0Vc.c./indefinite time. Door open:

Ulock = 12Vd.c./max. 0,75Ac.c./max. 10 sec.

LA1/LA2 – Connection of alternating current lock (max.5A/12Va.c.) Door locked: Ulock = 0Va.c./indefinite time. Door open:

Ulock = 12Va.c./24Va.c./max. 5,0Aa.c./max. 10 sec. (point 2, pg. 15)

LS1/LS2 – Connection of electromagnetic lock (max.3A/24Vc.c.) Door locked: Ulock = 12Vd.c./24Vd.c./max. 3,0Ad.c./

indefinite time. Door open: Ulock = 0Vd.c./max. 10 sec. (point 3)

SWC1/SWC2 – Connection of EXIT button (mounted inside the building)

AUX1/AUX2 – Connection of additional installations – auto gate, garage door, outdoor lighting etc. (point 4)

+ BAT/- BAT – Connection of rechargeable battery

DBL1/DBL2 – Connection of entrance doorbell (apartment doorbell)

GNG1/GNG2 – Connection of distance call doorbell (GONG)

B.1. Normal functioning mode, without BAT: the (Network) and +U LEDs are Green. The PROG and BAT LEDs are turned off.

2. Normal functioning mode, with BAT connected: the (Network), BAT and +U LEDs are Green.

3. The system functions only on battery (the system functions correctly until the full discharge of the battery): the BAT LED is

Green, the (Network) and +U LEDs are turned off. Check the fuses on the SCU (FUSE T-1, 6A) and 2x6A from the Network.

4. The system functions with a broken battery. The , +U LEDs are Green, the BAT LED is turned off. Change the battery!!!

5. The outdoor panel does not function (the Red LED from the video camera does not blink, the call keys are not backlighted):

The , BAT and +U LEDs are Green. The outdoor panel LED from the SCU is Red. Check the continuity and the accuracy of the

+U and GND connections from the SCU to the panel.

6. A terminal does not function (the keys are not backlighted when touched, there is no image and sound): the , BAT

and +U LEDs are Green. One of the OUT1, OUT2 or OUT3 LEDs is Red. Check the continuity and accuracy of the +U or GND

connections from the SCU to the terminal.

7. The direct current lock does not function (LC1, LC2), the LED is Red: check the accuracy of the connections to the lock.

8. The display of the terminal is Blue or Black (it functions during audio call): check the continuity of the Vin, Vout and GND

connections from the outdoor panel to the video terminal. If the connections are good, change the terminal.

9. The terminal cannot be called: a) (Terminal 2 or 3 has an incorrect address. The terminal at Family 1 is called!) Reprogram

terminals 2 or 3 with the correct address (the apartment number) according to Step 6.2.

b) If the PROG LED from the SCU is Red, check the continuity and the accuracy of the C/D, +U and GND connections from the

outdoor panel to the video terminal.

TROUBLESHOOTING AND SERVICE FOR THE VIDEO DOOR PHONE SYSTEM

PARALLEL CONNECTION OF TWO OUTDOOR PANELS (See the diagram from point 10)

If the building has multiple entrances, you can install VPA outdoor panels with their own SCU central supply unit, which will

command its own gate. The VPA1 main outdoor panel keeps address 1, set by the manufacturer and only the RFID access

cards/tags will be programmed at the VPA1 (see Step 5.1). The VPA2 additional panel is programmed with address 2 and

with the RFID access cards/tags (see Step 5.2).

PARALLEL CONNECTION OF THE ADDITIONAL TERMINALS (See the diagram from point 9)

Inside the residence you can install TL additional terminals (ATM/VTM 3.5”/ VTM 7”/ VTA 7”) using the same type

of cable, for the same connections (+U, C/D, GND, Vin/Vout). All the terminals in one apartment will have the

address of the main terminal. For Fam.1 the terminals have address 1 set by the producer. For Fam. 2, 3

(Fam. 4, 5 or more), program the terminals with addresses 2, 3 (or 4, 5 etc.). See Step 6.2.

2

Page 4: VIDEO DOOR PHONE KIT 3.5”/7” 1 Fam./2 Fam./ 3 Fam. EN User ... · Door open: Ulock = 0Vd.c./max. 10 sec. (point 3) SWC1/SWC2 – Connection of EXIT button (mounted inside the

4 5

+U

C/D

GND

Vin

+U

C/D

6mm

25-30mm

GND

Vout

6mm

25-30mm +U

C/D

GND

+U

C/D

GND

UTP cat5e (AWG24)

UTP cat6e (AWG23)

25-30mm6mm

VinVout

6mm25-30mm

21) Max. 75 ml 4 x 0.5 mm (H03VV-F4G 0.5) 22) Max. 150 ml 4 x 0.75 mm (H05VV-F4G 0.75)

3) Max. 250 ml UTP cat5e (AWG24)/UTP cat6e (AWG23)

SWC1

SWC2

LA1

LA2

LS1

LS2 N L

+U C/D

GN

DV

in1

LC1

LC2

DOOR LOCKSVIDEO DOOR PANEL

2x6Aa.c.

NL

max. 24 Va.c.50Hz/60Hz

LCK

LCK

VPA

max. 24Va.c./5Aa.c. 110Va.c./230Va.c.50Hz/60Hz

110Va.c./230Va.c.50Hz/60Hz

SCU

max. 24Vc.c./3Ac.c.

SWC1

SWC2

LA1

LA2

LS1

LS2 N L

+U C/D

GN

DV

in1

LC1

LC2

DOOR LOCKSVIDEO DOOR PANEL

max. 24 Vc.c.Electromagnet 110Va.c./230Va.c.50Hz/60Hzmax. 3 Ac.c.

+U GND

2x6Aa.c.

NL

110Va.c./230Va.c.50Hz/60Hz

AUX1AUX2+BAT-BAT

+U

Vin2GND+U

3-5 sec.

max. 24V/1A(a.c./c.c.)

3

1

2

3

LED PROGPROG

SCUSCU

SCU

SCU

EN

Page 5: VIDEO DOOR PHONE KIT 3.5”/7” 1 Fam./2 Fam./ 3 Fam. EN User ... · Door open: Ulock = 0Vd.c./max. 10 sec. (point 3) SWC1/SWC2 – Connection of EXIT button (mounted inside the

Vca

m

+U

GND

Vin2

SWC 1SWC 2

SW

C

LC 1LC 2

LCK

AUX 1AUX 2

LA 1LA 2LS 1LS 2

AU

X,

Fam

. 1(A

dr.

1)

VPA

(Ad

r.1

)

GNG 2

GNG 1

DBL 1DBL 2

Do

orb

ell

+U

C/D

GN

D

Vo

ut

+U

C/D

GN

D

Vo

ut

+U

C/D

GN

D

Vin

+U

C/D

GN

D

Vin

OU

TIN

Fam

1

GO

NG

SC

U

OUT1

+U

PRO

G

BA

T1

10

/23

0V

+BAT-BAT

12V/7Ah

BAT

+-

IN

11

0V

a.c.

, 50

Hz,

60

Hz

23

0V

a.c.

, 50

Hz,

60

Hz

LN

2x

6A

a.c.

6

4

EN

Page 6: VIDEO DOOR PHONE KIT 3.5”/7” 1 Fam./2 Fam./ 3 Fam. EN User ... · Door open: Ulock = 0Vd.c./max. 10 sec. (point 3) SWC1/SWC2 – Connection of EXIT button (mounted inside the

Vo

ut O

UT

INSWC 1SWC 2

SW

C

LC 1LC 2

LCK

AUX 1AUX 2

LA 1LA 2LS 1LS 2

AU

X,

Vin

SC

U

+BAT-BAT

12V/7Ah

BAT

+-

Fam

1V

ou

t

+U

C/D

GN

D

Vo

ut

OUT2 OUT1

Fam

. 1 (

Ad

r. 1

)

GNG 2

GNG 1

DBL 1DBL 2

Do

orb

ell

+U

C/D

GN

D

Vin

GO

NG

Do

orb

ell

GO

NG

5

+U

C/D

GN

D

Vca

m

+U

GND

Vin2

11

0V

a.c.

, 50

Hz,

60

Hz

23

0V

a.c.

, 50

Hz,

60

Hz

LN

2x

6A

a.c.

+U

C/D

GN

D

OUT3

+U

PRO

G

BA

T1

10

/23

0V

Fam

2

+U

C/D

GN

D

IN

Fam

. 2 (

Ad

r. 2

)

GNG 2

GNG 1

DBL 1DBL 2

+U

C/D

GN

D

Vin

7

VPA

(A

dr.

1)

EN

Page 7: VIDEO DOOR PHONE KIT 3.5”/7” 1 Fam./2 Fam./ 3 Fam. EN User ... · Door open: Ulock = 0Vd.c./max. 10 sec. (point 3) SWC1/SWC2 – Connection of EXIT button (mounted inside the

+U

C/D

GN

D

Vo

ut O

UT

IN

Fam

. 3 (

Ad

r. 3

)

GNG 2

GNG 1

DBL 1DBL 2

Do

orb

ell

+U

C/D

GN

D

Vin

GO

NG

Vca

m

+U

GND

Vin2

SWC 1SWC 2

SW

C

LC 1LC 2

LCK

AUX 1AUX 2

LA 1LA 2LS 1LS 2

AU

X,

11

0V

a.c.

, 50

Hz,

60

Hz

23

0V

a.c.

, 50

Hz,

60

Hz

LN

2x

6A

a.c.

+U

C/D

GN

D

Vo

ut

+U

C/D

GN

D

Vin

SC

U

OUT3

+U

PRO

G

BA

T1

10

/23

0V

+BAT-BAT

12V/7Ah

BAT

+-

Fam

2

Fam

1

Fam

3+

U

C/D

GN

D

Vo

ut

+U

C/D

GN

D

Vo

ut

OUT2 OUT1

IN

RO

Fam

. 1 (

Ad

r. 1

)

GNG 2

GNG 1

DBL 1DBL 2

Do

orb

ell

+U

C/D

GN

D

Vin

GO

NG

Fam

. 2 (

Ad

r. 2

)

GNG 2

GNG 1

DBL 1DBL 2

Do

orb

ell

+U

C/D

GN

D

Vin

GO

NG

8

6

VPA

(A

dr.

1)

EN

Page 8: VIDEO DOOR PHONE KIT 3.5”/7” 1 Fam./2 Fam./ 3 Fam. EN User ... · Door open: Ulock = 0Vd.c./max. 10 sec. (point 3) SWC1/SWC2 – Connection of EXIT button (mounted inside the

9

10

Designed and Manufactured by ELECTRA Made in EU

11.2017 INS.VK3.BLY04

+U

C/D

GND

Vin

+U

C/D

GND

Vout

GONGDOORBELL

DB

L1

DB

L2

GN

G1

GN

G2

VTM.7S402.xxy04/VTA.7S902.xxy04VIDEO 7"

+U

C/D

GND

Vin

+U

C/D

GND

Vout

+U

C/D

GND

Vin

VIDEO 3.5"VTM.3S402.xxy04

AUDIO ATM.0S402.xxy04

7

VPA1(Adr. 1)

1

VPA2(Adr. 2)

2VTM.7S402.xxy04/

VTA.7S902.xxy04/

VTM.3S402.xxy04/

ATM.0S402.xxy04/

+U

C/D

GND

Vout

+U

C/D

GND

Vout

+U

C/D

GN

D

Vin

+U

C/D

GND

Vout

+U

C/D

GND

Vin OU

T 1

SCU1

+U

C/D

GND

Vout

+U

C/D

GND

Vout

+U

C/D

GND

Vin OU

T 1

SCU2

VSB

+U

C/D

GN

D

Vin

+U

C/D

GND

Vin

OU

T

IN 1

IN 2

VID

EO

PA

NE

LV

IDE

O P

AN

EL

Fam 2

Fam 1

Fam 3

Fam 4

Fam 5

Fam 2

Fam 1

Fam 3

Fam 4

Fam 5

VCB

OUT 1

IN

OU

T 2

OU

T 3

OUT 4

+U

C/D

GND

Vout

+U

C/D

GND

Vout

+U

C/D

GN

D

Vo

ut

OUT

Fam.1

Fam.2

Fam.3

+U

C/D

GN

D

Vo

ut

Fam.4

+U

C/D

GN

D

Vo

ut

Fam.5

IN 4

IN 3

SW

C 1

SW

C 2

SWC

LC 1

LC 2

LCK

AU

X 1

AU

X 2

LA

1LA

2

LS 1

LS 2

AUX,

SW

C 1

SW

C 2

SWC

LC 1

LC 2

LCK

AU

X 1

AU

X 2

LA

1LA

2

LS 1

LS 2

AUX,

Vcam+U

GN

D

Vin

2

110Va.c., 50Hz, 60Hz230Va.c., 50Hz, 60Hz

L N

2x6Aa.c.

Vcam

+U

GN

D

Vin

2

110Va.c., 50Hz, 60Hz230Va.c., 50Hz, 60Hz

L N

2x6Aa.c.

EN

ELECTRA s.r.l Bd. Chimiei nr.8, Iași - 700291 - RO www.electra.ro

ELECTRA Bischoffgasse 5/3-4, 1120 Wien - AT +43 1 810 20 99

Building Communications GmbH

[email protected] www.bellcome.com

The products are

CE certified.

Certificate no. E307311

ISO 9001:2008ISO 14001:2009

Certificates no. 73 100 4856, 73 104 4856

by TÜV HESSEN

The products are manufactured under

Quality and Environment Management SystemR

The products contain UL-compliant

printed circuit boards.

Certificate by R 709 ICPE Certified

by NYCE

The products are

NOM certified.

BELLCOME is a trademark of ELECTRA Group - No. 013502646 EUIPO - Alicante, Spain

BELLCOME is a trademark of ELECTRA Group - No. 1732510 MPI - Ciudad de Mexico, Mexico

ELECTRA is a trademark of ELECTRA Group - No. 008958332 EUIPO - Alicante, Spain

BELLCOME/ELECTRA products are registered as Industrial Models at EUIPO - Alicante, Spain