x-series signal analyzer updates (w/ firmware rev. a.14.xx) a14 simplified.pdf · • an option...

24
X-Series Signal Analyzer Updates (w/ Firmware rev. A.14.xx) April 2014 1 Agilent Technologies Available May, 2014

Upload: others

Post on 13-Feb-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

  • X-Series Signal Analyzer Updates

    (w/ Firmware rev. A.14.xx)

    April 2014 1

    Agilent Technologies

    Available May, 2014

  • Agenda

    • What’s new with FW A.14 launch?

    – Platform new features and customer benefits

    – Measurement app enhancements

    • Win BIGGER against competition in mid-range

    • Where to find help

    April 2014

    Agilent Technologies

    2

  • New platform features

    April 2014

    Agilent Technologies

    3

    Highest freq. coverage

    • External mixing (Opt EXM) added on MXA

    • Covers up to 110 GHz w/Agilent smart mixer and 1.1 THz w/ VDI extender

    Best sensitivity

    • Noise floor extension (Opt NFE) on M/EXA

    • Up to 9 dB DANL improvement

    • USB smart preamps (U7227) for further DANL improvement

    Highest long-term

    freq. accuracy

    • Atomic freq. reference (AFR: J7203A)

    • Up to 100x better long-term freq. stability than precision freq. reference (PFR)

    World’s fastest power meas.

    • Fast power (Opt FP2) on P/M/EXA (w/ Opt B40)

    • For ACPR, band power, power density, …

    FW. Rev. A.14.00 or later required

    Pre-AFS – Feb. 1, 2014

    AFS – May 1, 2014

    SHP – May, 2014

    Web Go-live – May 1, 2014

    See backup slides for more details

  • Measurement apps: new and enhanced

    April 2014

    4

    Leadership in LTE-Advanced

    • N9080B/N9082B (LTE-A FDD/TDD)

    • FTD-258 (Mar. ‘14) for details

    Winning in WLAN

    • N/W9077A-4FP to improve EVM and speed for 802.11ac

    • FTD-262 (Apr. ‘14) for details

    Best for general-purpose

    • N9063A (Analog demod):

    • better and more hard specs

    • 8901A/B migration

    • N9069A (NF):

    • Supports USB smart preamp

    FW. Rev. A.14.00 or later required

  • Growing Millimeter-wave Applications

    • Backhaul radio systems

    • Automotive Radar

    • Early next-generation wireless research (“5G”)

    • 802.11ad WiGig

    • Aerospace/Defense

    Radar

    Secure Communication systems

    Highest freq. coverage

  • Page 6

    Option EXM • Available only on

    ALL new N9020A MXA ship w/ FW

    Rev. A. 14.00 or later

    • A 3.5 mm (f) connector providing triplex of

    LO-out/IF-in/DC bias

    • Support following external mixers

    Agilent M1970 smart mixers

    11970 legacy mixers (11970K excluded)

    OML mixers

    VDI mixers

    Farran mixers

    • Reference Price: $2,805

    External Mixing (N9020A-EXM)

    External mixers supported by N9020A-EXM

    Go beyond 26.5 GHz, up to 1.1 THz

    Adding Option EXM on MXA

    Highest freq. coverage

  • Upgradability of Option EXM

    • EXM upgrade only available on the MXA w/ SN

    prefix ≥ MY/SG/US5233 (i.e. with Option EP2)

    introduced Aug. 2013

    • There are two EXM upgrade options depending on

    MXA’s vintages 1. N9020AK-EXM ($3,305) for SN prefix between MY/SG/US5233 and

    MY/SG/US5328

    2. N9020AK-HL6 ($5,100) for SN prefix ≥MY/SG/US5328

    7

    for newer MXA (SN prefix ≥ MY/SG/US5233)

    Highest freq. coverage

  • NFE goes to mid-range signal analyzers

    • Introduce NFE (2nd Gen.) to MXA and EXA by May 2014

    • Up to 9-dB DANL improvement (specs to be set); longer delivery

    lead-time expected at launch (~12 week SRT)

    • An option (N9020A/N9010A-NFE) with price associated (Price:

    $5,000)

    • User upgradable (license-only) to the existing MXA/EXA’s

    (N9020AK/10AK-NFE @ price $5,000)

    • Shown as “N90x0A-NF2” in “Show system” license list

    • Requires firmware Rev. A.14.00 or later

    8

    MXA

    EXA

    For ALL vintages of MXA/EXA!

    Best sensitivity

  • How well does NFE work on MXA/EXA?

    • The preliminary result shows significant DANL

    improvement:

    9

    >9 dB

    • This specific EXA

    shows >9 dB DANL

    improvement

    • NFE “On” needs

    more average to

    reduce the noise floor

    fluctuation

    • Specifications will

    only be available 2~3

    months after launch

    (Long delivery lead-

    time @ launch)

    NFE: Off

    NFE: On

    Best sensitivity

  • U7227x USB Preamps

    Model Frequency Range Price (preliminary)

    U7227A 10 MHz to 4 GHz ~$4k

    U7227C 100 MHz to 26.5

    GHz

    ~$7k

    U7227F 2 to 50 GHz ~$13k

    Noise Fig ~ 5dB.

    Gain >17 dB (makes N Fig of SA

    negligible).

    USB provides power to Preamp, and reads

    factory-cal data from flash. Data includes

    gain, noise fig, and S-parameter data.

    “X” SA app uses amp as “remote front

    end”; gain data read over USB to correct

    displayed abs-amp vs frequency.

    “X” N Fig app uses amp to improve noise

    figure; noise data read over USB to support

    “Internal Cal”.

    Best sensitivity

    Int. preamp off

    Int. preamp on

    Ext. preamp on

  • Highest long-term frequency accuracy

    Key Applications: • Installation and maintenance of BTS • Low-cost alternative to primary house reference

    Key Customers: • NTT Docomo • Ericsson • Huawei • US Navy …

    Why it’s important? Extremely high frequency accuracy,

    stability and timing stability ensures the most precise synchronizations among multiple radio sub-systems

    Highest long-term

    freq. accuracy

  • Atomic Frequency Reference

    – The Atomic Frequency Reference (AFR) is a cesium-based

    atomic clock that PXA/MXA/EXA can use to discipline

    (adjust) the Internal 10 MHz Reference and effectively

    increasing the frequency accuracy.

    – Great alternative to a Primary Reference Standard which

    many labs and manufacturing facilities do not have.

    – Model Number: J7203A

    Highest long-term

    freq. accuracy

    No impact on phase noise!

    To “Ref in”

    on analyzer

    USB power from

    analyzer

  • Fast Power (Option FP2)

    • World’s Fastest Power Measurements!

    Power measurements include Channel power

    Adjacent channel power

    Band density

    Occupied bandwidth

    X-dB measurement

    Available on PXA, MXA, EXA

    Noise corrections included

    Option B40 (40 MHz analysis BW) required

    FW rev. A.14 or later required

    Reference price: $5,000

    • N90x0AK-FP2

    • Price: $5,000

    • Opt B40 required

    • License only

    World’s fastest power meas.

  • Fast Power (Option FP2)

    • Customer Problem

    Existing LXI-based test system: ACP Measurements

    Blazing fast power measurements: 76% Reduction in Test Time on

    this specific customer case

    AGILENT CONFIDENTIAL AGILENT CONFIDENTIAL A

    GIL

    EN

    T C

    ON

    FID

    EN

    TIA

    L A

    GIL

    EN

    T C

    ON

    FID

    EN

    TIA

    L

    World’s fastest power meas.

    Agilent Restricted

    April 2014

    (ms)

    900

    220

    0

    200

    400

    600

    800

    1000

    ACP (MXA)

    Current Time New Time (ms)

  • What’s New for N9063A Analog Demod

    Tx Attack/Release view: see RF envelope & FM demod on same T-axis

    Marker Table on AF Spectrum: easily quantify multi-tone case

    Analog Out: eliminate clipping/scaling/wrapping problems for FM & PM

    Wide BW: support demod to 160 MHz BW

    Long Demod Waveform:

    up to 3.6 MSa, or >100 sec at 25 kHz BW

    Improved many specs

    For N9063A installed base customers the

    N9063A-AFP may be required for new

    enhancements

  • Migrate 8901A/B to X-Series

    Agilent Technologies

    8901A/B

    modulation analyzer X-Series with

    N9063A analog

    demod app

    Filters: add many post-demod filters; modify to mimic

    HP 89xx

    Ref Ratio User Entry: manually enter reference for

    FM Hum & Noise (like 8901)

    SNR: emulate HP 8903 SNR feature

    Warranted hard specs: add more

    The following new enhancements

    on N9063A particularly help to

    accelerate the 890x to X-Series

    April 2014

  • New Minor Enhancements Update (- MEU) Option

    17

    Apps Model # Price

    (US$)

    GSM/EDGE N/W9071A

    W-CDMA N/W9073A

    TD-SCDMA N/W9079A

    Bluetooth N/W9081A

    Analog Demod. N/W9063A

    VXA N/W9064A

    Phase Noise N/W9068A

    Noise Figure N/W9069A

    Digital Cable TV N/W6152A

    • MCD-SA introduces an unified option of

    MEU to all existing applications with

    minor enhancement updates

    • For install-based customers, when they

    need to upgrade to the latest application

    SW with enhancements, they just order

    -MEU in hundred $

    • For new buy customers, they always can

    have the latest application features in the

    SW

    • In SA-A.14, total 9 applications move to the new structure

    • Enhanced feature description will be listed on the application webpage with revision number

  • Pricing summary

    Model Option Description Ref.

    Price

    (US$)

    Notes

    N9020A/AK-NFE Noise floor extension Upgradable to all MXA

    N9010A/AK-NFE Noise floor extension Upgradable to all EXA

    N9020A-EXM External mixing

    N9020AK-EXM Upgrade external mixing Serial prefix between 5233

    and 5328

    N9020AK-HL6 Upgrade external mixing serial prefix ≥ 5328

    N90x0A/AK-FP2 Fast Power, up to 40 MHz bandwidth Requires Opt B40

    N90x0A/AK-SF2 Security features, prohibit saving results N90x0A/AK-SF2

    J7203A Atomic frequency reference For P/M/EXA

    U7227A USB “smart” preamp, 10 MHz to 4 GHz For P/M/E/CXA

    U7227C USB “smart” preamp, 0.1 to 26.5 GHz For P/M/E/CXA

    U7227A USB “smart” preamp, 2 to 50 GHz For P/M/E/CXA

  • Source control (Opt ESC) to support extn’l mixing

    (Opt EXM)

    19

    • Makes mmW scalar stimulus-response tests beyond 50 GHz

    possible

    Enables the P/M/mmW EXA to control the external source with frequency

    extender (eg. OML, VDI module) for high-frequency stimulus

    Enables the P/M/mmW EXA with Opt EXM and an external mixer (eg. Agilent

    smart mixer) to receive the high-frequency responses

    Incident signal

    Reflected signal

    Transmitted signal

    An example of measured result @ 85 GHz

  • 20

    LAN/USB/GPIB

    DUT

    Freq.

    extender External

    mixer

    PSG X-Series w/ Opts

    EXM and ESC*

    USB

    IF/LO

    RF

    Trigger-in Trigger-out Trigger-in Trigger-out

    Wave-guide

    Setup for mmW scalar stimulus-response tests

    *: FW. A.14 or later required for X-Series AS

  • Recap- XA14 Major Enhancements

    21

    Model/Opt Description PXA MXA EXA CXA

    N9080B/82B LTE-Advanced New New New -

    -EXM Ext. mixing New * -

    -NFE NFE2 implementation + New New -

    N9068A Analog demod + + + +

    U7227A/C/F Smart preamp support New New New New

    J7203A Atomic Freq. Reference New New New -

    -FP2 Fast ACPR power meas’t New New New -

    -W7X Win7 New

    -ESC External source control to

    support EXM

    +

    +

    +

    -

    New: Newly added

    : Existing

    +: Enhance on existing

    -: Not available

    To be introduced May 2014

    *: for mmW EXA only

  • X-Series Signal Analyzer Portfolio

    EXA 10 Hz to 44 GHz

    MXA 10 Hz to 26.5 GHz

    Sep 06

    Sep 07

    Oct 09

    PXA 3 Hz to 50 GHz

    Perf

    orm

    ance

    Price

    89600B VSA software Premier signal analysis & troubleshooting

    MXE 20 Hz to 44 GHz

    CISPR 16-1-1 2010

    Compliant EMI Receiver

    CXA 9 kHz to 26.5 GHz

    Oct 09

    Master the Essentials

    Balance the Challenges

    Accelerate in Wireless

    Drive your Evolution

    Investment continues!

  • New N9080B/N9082B LTE-Advanced FDD/TDD

    Analyze signal and multi-carrier LTE/LTE-

    Advanced FDD/TDD signals

    Downlink and uplink analysis in a single option

    Support carrier aggregation of up to 5

    contiguous/non-contiguous components carriers

    support for uplink & downlink:

    For TDD, all DL/UL and special subframe length

    configurations

    One-button support transmitter characteristic

    measurements for Base station and User

    equipment

    Requires Win 7 OS on PXA, MXA or EXA signal

    analyzers; does NOT support Win XP OS.

    Maximum analysis bandwidth required – B25

    (25 MHz). EVM measurements are sequential

    i.e. demods one CC at a time & max BW of a

    CC is 20 MHz.

    • N9080B-2FP – LTE-Advanced FDD

    • Requires N9080A-1FP or N9080B-1FP

    • N9082B-2FP – LTE-Advanced TDD

    • Requires N9082A-1FP or N9082B-1FP

    • Price for option 2FP - $4.5k

    For more information please Contact:

    Martha Zemede (T345-8307) or

    To learn SA_258 Recording module

    on March-FTD

  • N9077A WLAN Measurement Application Updates

    Make multi-burst capture and averaging for modulation analysis to increase EVM

    measurement speed up to 30%

    Improve RF input range and EVM floor to

    win completion with FSW

    Provide unique IQ impairments per

    subcarrier features per customer requests

    • gain imbalance

    • quadrature skew

    802.11a/n: Mask updates per recent

    standards changes

    802.11p 5 MHz BW support

    (10, 20 MHz BW already supported)

    • N9077A-4FP – 802.11ac FDD

    • Requires N9077A-2FP (802.11 a/b/g)

    • Requires N9077A-3FP (802.11n)

    • Free Upgrade for Install-based customers

    For more information please Contact:

    John Harmon (T577-3983) or

    To learn SA_262 Recording module

    on April-FTD