05 Motori , Servomotori , Misura & SistemiMotor, servo-drives, measurement & system cables
Advantage EPLAN®:The entire TKD assortment is also available in the EPLAN® format. This allows you to insert the relevant cables into your constructional drawing and wiring diagrams by using the “Drag & Drop” function.www.tkd-kabel.de/eplan
Cavi per servo-drives 0,6/1kV
Feedback-, Encoder-, Resolver-, Tachimetriche-,
Segnali schermati per sistemi
Cavi per uso in ambienti e condizioni gravose
KAWEFLEX® Allround 0,6/1kV
...approvati UL/CSA
...per posa fissa o flessibile
...per uso dinamico in catena
...compatibili con i sistemi più diffusi.:
B&R , Baumüller, Berger Lahr, Control Techniques,
ELAU, Fagor, FANUC, Heidenhain, Jetter, Lenze,
LTi DRiVES, NUM, Omron, Rexroth, SEW, Siemens,
Sick, Stöber, u.a.
Cables for servo-drives 0,6/1kV
Feedback, encoder, resolver, speedo sensor,
signal system cables, shielded
Drag chain cables for harsh operating conditions
KAWEFLEX® Allround Motor cables 0,6/1kV
...approved versions with UL/CSA
...for fixed & flexible installation
...for highly flexible use in drag chains
...compatible systems for example:
B&R, Baumüller, Berger Lahr, Control Techniques,
ELAU, Fagor, FANUC, Heidenhain, Jetter, Lenze,
LTi DRiVES, NUM, Omron, Rexroth, SEW, Siemens,
Sick, Stöber, a.o.
05
Individual Cable Solutions
It is our aim to find the best possible solution for your requirements however complex or unique those requirements might be.
In addition to our standard product range we actively develop product and system solutions with our customers to meet their specific needs. Our tailor-made solutions convince through operational excellence, quality and economic efficiency.
We gladly provide personal in-house and/or on-site advice. TKD sales representatives and technical engineers are available to answer your technical queries regarding application, product characteristics and choice of materials.
Our customers can benefit from our cable technology know-how straight from the beginning of the products’ development stage.
Soluzioni pensate per te
Il nostro obiettivo è quello di trovare sempre la soluzione migliore per voi, non importa quanto complessa o come siano uniche le vostre esigenze.
Oltre ai nostri prodotti standard, possiamo progettare, insieme a voi, su misura per le vostre esigenze soluzioni e prodotti che soddisfino le vostre richieste tecniche, di qualità o costo.
Possiamo supportarvi direttamente nella vostra azienda o in cantiere. La rete vendita e l‘ufficio tecnico di TKD sono disponibili per rispondere a questioni tecniche relative all‘applicazione, alle caratteristiche del prodot-to e alla scelta dei materiali.
I nostri clienti possono beneficiare del nostro know-how sui cavi diretta-mente nella fase di sviluppo del prodotto.
librerie EPLAN®:L‘intera gamma di prodotti TKD è disponibile in libreria EPLAN® . Nella costruzione di schemi e disegni basterà semplicemente selezionare i prodotti dal menu.www.tkd-kabel.de/eplan
05
Capitolo e tipologia Pagina
Cavi per servomotori 0,6/1 kV con approvazione UL/CSA..................05.02
KAWEFLEX® 5112 SK PVC UL/CSA - SK C PVC UL/CSA ........................... 05.02.01
KAWEFLEX® 5121 SK PUR UL/CSA SERVO 0,6/1 kV .................................. 05.02.02
KAWEFLEX® 5288 SK C PUR UL/CSA SERVO 0,6/1 kV .........................05.02.05.02
KAWEFLEX® 5278 SK C PVC UL/CSA SERVO 0,6/1kV,..........................05.02.05.03
KAWEFLEX® 5268 C PVC UL/CSA SERVO 0,6/1kV ................................05.02.05.04
KAWEFLEX® 52DSL C PVC UL/CSA 0,6/1 kV ................................................ 05.02.30
KAWEFLEX® 52DSL SK C PUR UL/CSA 0,6/1 kV .......................................... 05.02.35
Feedback-, Encoder-, Resolver-, Tachimetriche-,
cavi di segnale schermati ...........................................................................05.04
KAWEFLEX® 5468 C PVC UL/CSA .................................................................... 05.04.05
KAWEFLEX® 5488 SK C PUR UL/CSA .............................................................. 05.04.10
KAWEFLEX® ServoDriveQ C PVC UL/CSA ...............................................05.04.15.01
KAWEFLEX® ServoDriveQ FLEX C PVC UL/CSA.....................................05.04.15.02
KAWEFLEX® ServoDriveQ SK C PUR UL/CSA, ........................................05.04.15.03
KAWEFLEX® ServoDriveQ Plus SK C PUR UL/CSA ................................05.04.15.04
KAWEFLEX® Allround 0,6/1kV ...................................................................05.10
KAWEFLEX® Allround 7510 SK TPE UL/CSA ................................................ 05.10.05
KAWEFLEX® Allround 7520 SK TPE UL/CSA (G/V) ..................................... 05.10.10
KAWEFLEX® Allround 7610 SK C TPE UL/CSA ............................................ 05.10.15
KAWEFLEX® Allround 7310 SK PVC UL/CSA ............................................... 05.10.20
KAWEFLEX® Allround 7320 SK TPE UL/CSA ................................................ 05.10.25
KAWEFLEX® Allround 7410 SK C PVC UL/CSA ........................................... 05.10.30
KAWEFLEX® Allround 7420 SK-C-TPE UL/CSA ........................................... 05.10.35
Definition of cables Page
Cables for servo-drives 0,6/1 kV ...............................................................05.01
KAWEFLEX® 5112 SK PVC UL/CSA - SK C PVC UL/CSA ........................... 05.02.01
KAWEFLEX® 5121 SK PUR UL/CSA SERVO 0,6/1 kV .................................. 05.02.02
KAWEFLEX® 5288 SK C PUR UL/CSA SERVO 0,6/1 kV .........................05.02.05.02
KAWEFLEX® 5278 SK C PVC UL/CSA SERVO 0,6/1kV,..........................05.02.05.03
KAWEFLEX® 5268 C PVC UL/CSA SERVO 0,6/1kV ................................05.02.05.04
KAWEFLEX® 52DSL C PVC UL/CSA 0,6/1 kV ................................................ 05.02.30
KAWEFLEX® 52DSL SK C PUR UL/CSA 0,6/1 kV .......................................... 05.02.35
Feedback, encoder, resolver, speedo sensor, signal and
system cables, shielded, with UL/CSA approval ....................................05.04
KAWEFLEX® 5468 C PVC UL/CSA .................................................................... 05.04.05
KAWEFLEX® 5488 SK C PUR UL/CSA .............................................................. 05.04.10
KAWEFLEX® ServoDriveQ C PVC UL/CSA ...............................................05.04.15.01
KAWEFLEX® ServoDriveQ FLEX C PVC UL/CSA.....................................05.04.15.02
KAWEFLEX® ServoDriveQ SK C PUR UL/CSA, ........................................05.04.15.03
KAWEFLEX® ServoDriveQ Plus SK C PUR UL/CSA ................................05.04.15.04
KAWEFLEX® Allround 0,6/1kV ...................................................................05.10
KAWEFLEX® Allround 7510 SK TPE UL/CSA ................................................ 05.10.05
KAWEFLEX® Allround 7520 SK TPE UL/CSA (G/V) ..................................... 05.10.10
KAWEFLEX® Allround 7610 SK C TPE UL/CSA ............................................ 05.10.15
KAWEFLEX® Allround 7310 SK PVC UL/CSA ............................................... 05.10.20
KAWEFLEX® Allround 7320 SK TPE UL/CSA ................................................ 05.10.25
KAWEFLEX® Allround 7410 SK C PVC UL/CSA ........................................... 05.10.30
KAWEFLEX® Allround 7420 SK-C-TPE UL/CSA ........................................... 05.10.35
...............NEW..........................................
............NEW..........................
...............NEW.....................................
...............NEW..........................................
............NEW..........................
...............NEW.....................................
Maggiori informazioni
Maggiori informazioni sui nostri „cavi SERVO“ sono reperibili sul nostro
sito internet o allo 051 790636 dove uno specialista potrà fornire tutte le
informazioni necessarie.
Further comprehensive Service
Detailed information on the subject of „SERVO cables” and other cable
types can be found at www.tkd-kabel.de or
request them to your contact person.
05
KA
WE
FL
EX
® famiglie di prodotti sostituite da serie 6 products in phase out new line is 6 series
05
.02
.05
.04
31
10
SK
-PV
C
31
20
SK
-PU
R
31
30
SK
-PU
R
32
10
SK
-C-P
VC
32
25
SK
-C-P
UR
32
30
SK
-C-P
UR
33
10
SK
-PV
C
33
20
SK
-PU
R
33
25
SK
-C-P
VC
33
40
SK
-TP
-C-P
UR
35
10
RO
B-P
UR
/RO
B-C
-PU
R
42
70
C-P
VC
51
10
SK
-PV
C
51
12
SK
-PV
C/S
K-C
-PV
C
51
15
SK
-PU
R
51
30
SK
-PU
R
52
15
SK
-C-P
UR
52
30
SK
-C-P
UR
52
68
C-P
VC
flessibile, limitato uso in catena flexible, conditionally capable for drag chains
cara
tter
istic
hepr
oper
ties
idoneo all‘usoin catena capable for drag chains
x x x x x x x x x x x x x x x x x
per torsione robotic application, torsion
x
schermato shield
x x x x x x x x x
approvazione cUL cUL-approved
x x x x x x x
bassa capacità low capacity
x
resistente agli oli resistant to oil
x x x x x x x x x x x x x
autoestinguente flame-retardant
x x x x x x x x x x x x x x x x x x x
privo di alogeni halogen-free
x x x x x x x x
cavo di segnale electronic cable
tipo
type
x x x x
cavo di controllo control cable
x x x x x x x x x x x x x
cavo SERVO Motor supply cable
x
cavo SERVO + 2 cond. sch. Motor supply cable + 2 schielded cores
cavo SERVO + 1 coppia sch. Motor supply cable + 1 shielded pair
x
cavo SERVO + 2 coppie sch. Motor supply cable + 2 shielded pairs
x
applicazioni leggere light requirement
appl
icaz
ione
appl
ikat
ionrequisiti normali/medi
normal/medium requirementx x x x x x x x
requisiti aumentati increased requirement
x x x x
requisiti elevati high requirement
x x x x x
requisiti estremi highest requirement
idoneo a SIEMENS e.g. for system SIEMENS
sist
emi
syst
em
x x
idoneo a BOSCH e.g. for system BOSCH
x
idoneo a INDRAMAT e.g. for system INDRAMAT
x
idoneo a HEIDENHAIN e.g. for system Heidenhain
idoneo a LENZE e.g. for system LENZE
x
idoneo a SEW e.g. for system SEW
05
KA
WE
FL
EX
®
05
.02
.05
.03
05
.02
.05
.02
05
.02
.30
05
.02
.35
04
.06
.03
04
.06
.04
4.0
9.0
5
04
.09
.10
04
.09
.15
04
.09
.20
04
.09
.25
04
.09
.30
04
.10
.05
04
.10
.10
04
.10
.15
04
.10
.20
04
.10
.25
04
.11
.30
52
78
SK
-C-P
VC
52
88
SK
-C-P
UR
52
DS
L C
-PV
C
52
DS
L S
K-C
-PU
R
53
30
SK
-C-P
VC
53
40
SK
-C-P
UR
61
00
EC
O S
K-P
VC
61
10
SK
-PV
C
61
30
SK
-PU
R
62
00
EC
O S
K-C
-PV
C
62
10
SK
-C-P
VC
62
30
SK
-C-P
UR
63
10
SK
-PV
C
63
30
SK
-PU
R
64
10
SK
-C-P
VC
64
30
SK
-C-P
UR
65
10
SK
-TP
-C-P
VC
65
30
SK
-TP
-C-P
UR
flessibile, limitato uso in catena flexible, conditionally capable for drag chains
cara
tter
istic
hepr
oper
ties
x
idoneo all‘usoin catena capable for drag chains
x x x x x x x x x x x x x x x x x
per torsione robotic application, torsion
schermato shield
x x x x x x x x x x x x x
approvazione cUL cUL-approved
x x x x x x x x x x x x x x x x x x
bassa capacità low capacity
x x x x x x
resistente agli oli resistant to oil
x x x x x x x x x x x x x x x x x
autoestinguente flame-retardant
x x x x x x x x x x x x x x x x x x
privo di alogeni halogen-free
x x x x x x x x
cavo di segnale electronic cable
tipo
type
x x x x x x x
cavo di controllo control cable
x x x x x x
cavo SERVO Motor supply cable
x x x x
cavo SERVO + 2 cond. sch. Motor supply cable + 2 schielded cores
x
cavo SERVO + 1 coppia sch. Motor supply cable + 1 shielded pair
x x
cavo SERVO + 2 coppie sch. Motor supply cable + 2 shielded pairs
x
applicazioni leggere light requirement
appl
icaz
ione
appl
ikat
ion
x x
requisiti normali/medi normal/medium requirement
x x x x x x x x x
requisiti aumentati increased requirement
x x
requisiti elevati high requirement
x x x x x x x
requisiti estremi highest requirement
idoneo a SIEMENS e.g. for system SIEMENS
sist
emi
syst
em
x x x
idoneo a BOSCH e.g. for system BOSCH
x
idoneo a INDRAMAT e.g. for system INDRAMAT
x
idoneo a HEIDENHAIN e.g. for system Heidenhain
x
idoneo a LENZE e.g. for system LENZE
x
idoneo a SEW e.g. for system SEW
x
05
All
rou
nd
®
04
.11
.05
04
.11
.10
04
.11
.15
04
.11
.20
04
.11
.25
04
.11
.30
05
.10
.20
05
.10
.25
05
.10
.30
05
.10
.35
05
.10
.05
05
.10
.10
05
.10
.15
04
.15
.05
04
.15
.10
04
.15
.15
71
10
SK
-PV
C
71
30
SK
-PU
R
71
40
SK
-TP
E
72
10
SK
-C-P
VC
72
30
SK
-C-P
UR
72
40
SK
-C-T
PE
73
10
SK
-PV
C
73
20
SK
-TP
E
74
10
SK
-C-P
VC
74
20
SK
-C-T
PE
75
10
SK
-TP
E
75
20
SK
-TP
E
76
10
SK
-C-T
PE
77
10
SK
-TP
-C-P
VC
77
20
SK
-TP
-C-P
UR
77
30
SK
-TP
-C-T
PE
flessibile, limitato uso in catena flexible, conditionally capable for drag chains
cara
tter
istic
hepr
oper
ties
idoneo all‘usoin catena capable for drag chains
x x x x x x x x x x x x x x x x
per torsione robotic application, torsion
schermato shield
x x x x x x x x x
approvazione cUL cUL-approved
x x x x x x x x x x x x x
bassa capacità low capacity
resistente agli oli resistant to oil
x x x x x x x x x x x x x x x x
autoestinguente flame-retardant
x x x x x x x x x x x x x
privo di alogeni halogen-free
x x x x x x x x x x x
cavo di segnale electronic cable
tipo
type
x x x
cavo di controllo control cable
x x x x x x
cavo SERVO Motor supply cable
x x x x x x x
cavo SERVO + 2 cond. sch. Motor supply cable + 2 schielded cores
cavo SERVO + 1 coppia sch. Motor supply cable + 1 shielded pair
cavo SERVO + 2 coppie sch. Motor supply cable + 2 shielded pairs
applicazioni leggere light requirement
appl
icaz
ione
appl
ikat
ionrequisiti normali/medi
normal/medium requirement
requisiti aumentati increased requirement
x x x
requisiti elevati high requirement
x x x x
requisiti estremi highest requirement
x x x x x x x x x
idoneo a SIEMENS e.g. for system SIEMENS
sist
emi
syst
em
idoneo a BOSCH e.g. for system BOSCH
idoneo a INDRAMAT e.g. for system INDRAMAT
idoneo a HEIDENHAIN e.g. for system Heidenhain
idoneo a LENZE e.g. for system LENZE
idoneo a SEW e.g. for system SEW
05
KAWEFLEX®
cavo per catene per requisiti leggeri
drag chain cable
for light requirements
cavo per catene per requisiti medi
drag chain cable for normale, medium
requirements
cavo per catene per requisiti aumentati
drag chain cable
for increasedrequirements
cavo per catene per requisiti elevati
drag chain cable
for highrequirements
cavo per catene per requisiti estremi
drag chain cable
extremerequirements
valori di riferimento per cavi BUS
bus cable
for drag chain application
raggio minimo di curv. minimum bending radius
10 x d (< 3m VW / TL) 12,5 x d (≥ 3m VW / TL) 7,5 x d 7,5 x d 7,5 x d 5 x d 7,5 x d
velocità massima max traverse speed 3 m/s 4 m/s 6 m/s 10 m/s 10 m/s 4 m/s
lmax. unghezza catena max traverse length TL 10 m 10 m 25 m 50 m 100 m 10 m
max. accelerazione max acceleration 10 m/s² 5 m/s² 10 m/s² 10 m/s² 10 m/s² 5 m/s²
cicli di piegatura bending cycles > 1 Mio 3 Mio 3 Mio 5 Mio 5 Mio 3 Mio
resistenza all‘abrasione resistant to abraision
BassoLow
BassoLow
AltoHigh
AltoHigh
AltoHigh
AltoHigh
resistenza agli oli resistant to oil DIN EN 60811-404 DIN EN 60811-404 DIN EN 60811-404 DIN EN 60811-404 DIN EN 60811-404 DIN EN 60811-404
temperatura d‘esercizio operating temperature -5 °C / +70 °C -5 °C / +70 °C -5 °C / +70 °C -5 °C / +70 °C -30 °C / +80 °C -30 °C / +80 °C
Parametri per applicazione dei cavi in catena Parameter in drag chain cable application
Il numero di cicli è stato determinato e testato in condizioni standardizzate in sistemi di catene con velocità di traslazione e corsa programmabili ed è possibile a condizione di una corretta installazione e sottoponendo il prodotto a sollecitazioni nel rispetto dei partametri meccanici e di temperatura ammessi.I nostri tecnici saranno lieti di rispondere alle vostre domande.Si prega seguire istruzioni per l‘installazione presenti nelle „linee guida tecniche“ al CAP 16.
The number of cycles was determined under standardised conditions in power chain systems with programmable traverse speeds and traverse lengths and is only possible if installed correctly and at under continous motions and constant temperature conditions.Our service technicians will be glad to answer your further questions.Please find our installation instructions in the Technical Guidelines.
05
KAWEFLEX®
Allround
cavi di controllo / control cables cavi di segnale / electronic cables
cavo per catene per requisiti aumentati
drag chain cable
for increasedrequirements
cavo per catene per requisiti elevati
drag chain cable
for highrequirements
cavo per catene per requisiti
estremi
drag chain cablefor highest
requirements
cavo per catene per requisiti aumentati
drag chain cable
for increasedrequirements
cavo per catene per requisiti elevati
drag chain cable
for highrequirements
cavo per catene per requisiti estremi
drag chain cable
for highestrequirements
tipo types
...7110 SK-PVC …7210 SK-C-PVC
...7130 SK-PUR ...7230 SK-C-PUR
...7140 SK-TPE ...7240 SK-C-TPE ...7710 SK-TP-C-PVC ...7720 SK-TP-C-PUR ...7730 SK-TP-C-TPE
min. raggio curvatura min. bending radius
6,5 x d (< 10m VW / TL) 7,5 x d (≥ 10m VW / TL)
6,5 x d (< 10m VW / TL) 7,5 x d (≥ 10m VW / TL) 5 x d 10 x d 10 x d 10 x d
max. velocità traslazione max. traverse speed 10 m/s 10 m/s 10 m/s 5 m/s 10 m/s 10 m/s
max. corsa catena max. traverse length (TL) 100 m 100 m 400 m 100 m 100 m 400 m
max. accelerazione max. admissible acceleration
80 m/s² 80 m/s² 100 m/s² 50 m/s² 80 m/s² 100 m/s²
resistenza abrasione resistant to abraision
BassaLow
AltaHigh
AltaHigh
BassaLow
AltaHigh
AltaHigh
resistenza agli oli resistant to oil DIN EN 60811-404 DIN EN 60811-404 DIN EN 60811-404 DIN EN 60811-404 DIN EN 60811-404 DIN EN 60811-404
temperatura d‘esercizio operating temperature -5 °C / +70 °C -25 °C / +80 °C -25 °C / +100 °C -20 °C / +80 °C -25 °C / +80 °C -25 °C / +100 °C
KAWEFLEX®
Allround
Motorleitungen / motor cables
….multipolari / multi core … unipolari / single core
cavi per requisiti elevati drag chain cable for high requirements
cavi per requisiti estremi drag chain cable for highest requirements
cavi per requisiti estremi drag chain cable for highest requirements
tipo types
...7310 SK-PVC ...7410 SK-C-PVC
...7320 SK-TPE ...7420 SK-C-TPE
...7510 SK-TPE, …7520 SK-TPE ...7610 SK-C-TPE
min. raggio curvatura min. bending radius 7,5 x d 7,5 x d 7,5 x d
max. velocità traslazione max. traverse speed 10 m/s 10 m/s 10 m/s
max. corsa catena max. traverse length (TL) 100 m 400 m 400 m
max. accelerazione max. admissible acceleration
80 m/s² 80 m/s² 100 m/s²
resistenza abrasione resistant to abraision
BassoLow
AltoHigh
AltoHigh
resistenza agli oli resistant to oil DIN EN 60811-404 DIN EN 60811-404 DIN EN 60811-404
temperatura d‘esercizio operating temperature -5 °C / +70 °C -35 °C / +90 °C -35 °C / +90 °C
Parametri per applicazione dei cavi in catena Parameter in drag chain cable application
05
KAWEFLEX®
ServoDriveQ…
ServoDriveQ
C-PVC
ServoDriveQ
FLEX-C-PVC
ServoDriveQ
SK-C-PUR
ServoDriveQ Plus
SK-C-PUR
per posa fissa e flessibile for fixed & limited flexible
installation
flessibile a bassa dinamica flexible & limited for drag chain
applications
per applicazioni dinamiche for drag chain applications
per applicazioni dinamiche for drag chain applications
approvazioniapprobations UL / CSA UL / CSA UL / CSA UL / CSA
sezionidimensions
2x2x0,22(AWG24/7)
2x2x0,22+1x2x0,38(AWG24/7 - AWG22/19)
2x2x0,15+1x2x0,38(AWG26/19 - AWG22/19)
2x2x0,20+1x2x0,38(AWG24/19 - AWG22/19)
velocità trasmissionetransfer rate 100 Mbit/s 100 Mbit/s 100 Mbit/s 100 Mbit/s
max. lunghezza ammessaat max. length of use 100 m 100 m 50 m 70 m
min. raggio curvaturamin. bending radius singolo / single multiplo /multiple
7,5 x d15 x d
35 mm125 mm
35 mm105 mm
35 mm75 mm
max. velocità traslazionemax. traverse speed ./. 3 m/s 3 m/s 5 m/s
max. corsa catenamax. traverse length ./. 5 m 5 m 10 m
max. accelerazionemax. admissible acceleration ./. 2 m/s² 5 m/s2 (5 m)
10 m/s² (2,5 m)max.10 m/s2 (5 m)
max.30 m/s² (2,5m)
cicli di piegaturabending cycles ./. 100.000 5 Mio. 5 Mio.
max. torsionemax. admissible torsion ./. ≤ ± 30°/m ≤ ± 30°/m ≤ ± 30°/m
resistenza abrasioneresistant to abrasion
BassaLow
BassaLow
AltaHigh
AltaHigh
max. forza trazionemax. pulling force fisso/fixed mobile/moved
50N/mm²20N/mm²
50N/mm²20N/mm²
50N/mm²20N/mm²
50N/mm²20N/mm²
resistenza agli oliresistant to oil EN 60811-2-1 EN 60811-2-1 EN 60811-2-1 EN 60811-2-1
temperatura conservazionestorage temperature min./max. -40 °C / +80 °C -40 °C / +80 °C -40 °C / +80 °C -40 °C / +80 °C
temperatura eserciziooperating temperature fisso/fixed min./max. mobile/moved min./max.
-20 °C / +80 °C -20 °C / +80 °C 0 °C / +60 °C
-20 °C / +80 °C-20 °C / +60 °C
-20 °C / +80 °C-20 °C / +60 °C
Parametri per applicazione dei cavi in catena Parameter in drag chain cable application
Il numero di cicli è stato determinato e testato in condizioni standardizzate in sistemi di catene con velocità di traslazione e corsa programmabili ed è possibile a condizione di una corretta installazione e sottoponendo il prodotto a sollecitazioni nel rispetto dei partametri meccanici e di temperatura ammessi.I nostri tecnici saranno lieti di rispondere alle vostre domande.Si prega seguire istruzioni per l‘installazione presenti nelle „linee guida tecniche“ al CAP 16.
The number of cycles was determined under standardised conditions in power chain systems with programmable traverse speeds and traverse lengths and is only possible if installed correctly and at under continous motions and constant temperature conditions.Our service technicians will be glad to answer your further questions.Please find our installation instructions in the Technical Guidelines.
05
KA
WE
FL
EX
®
43
xx
05
.03
.01
44
xx
05
.03
.02
44
xx
0
5.0
3.0
2
43
04
C-P
VC
43
08
C-P
VC
43
12
C-P
VC
43
16
C-P
VC
43
20
C-P
VC
43
24
C-P
VC
43
28
C-P
VC
43
36
C-P
VC
43
44
C-P
VC
43
48
C-P
VC
43
76
C-P
VC
43
80
C-P
VC
43
88
C-P
VC
44
04
SK
-C-P
UR
44
08
SK
-C-P
UR
44
12
SK
-C-P
UR
44
16
SK
-C-P
UR
44
20
SK
-C-P
UR
44
24
SK
-C-P
UR
44
32
SK
-C-P
UR
44
36
SK
-C-P
UR
44
40
SK
-C-P
UR
44
44
SK
-C-P
UR
44
48
SK
-C-P
UR
44
52
SK
-C-P
UR
44
61
SK
-C-P
UR
44
64
SK
-C-P
UR
44
68
SK
-C-P
UR
44
72
SK
-C-P
UR
44
76
SK
-C-P
UR
44
80
SK
-C-P
UR
44
84
SK
-C-P
UR
44
88
SK
-PU
R
form
azio
nedi
men
sion
10x0
,14
+ 2x
0,5
10x0
,14
+ 4x
0,5
15x0
,14
+ 4x
0,5
3x2x
0,14
+ 2
x0,5
3x(2
x0,1
4) +
2x(
0,5)
3x(2
x0,1
4) +
2x1
3x(2
x0,1
4) +
4x0
,14+
2x0,
5
3x(2
x0,1
4) +
3x2
x0,2
5
4x2x
0,25
+ 4
x0,2
5
4x2x
0,25
+ 4
x0,5
nx2x
0,18
und
50x
0,18
4x2x
0,25
+2x1
12x(
2x0,
14)
10x0
,14+
2x0,
5
10x0
,14+
4x0,
5
15x0
,14+
4x0,
5
3x2x
0,14
+2x0
,5
3x(2
x0,1
4)+2
x(0,
5)
3x(2
x0,1
4)+2
x1
3x(2
x0,1
4)+4
x0,1
4+4x
0,25
+2x0
,5
3x(2
x0,1
4)+3
x2x0
,25
4x2x
0,14
4x2x
0,25
+4x0
,25
4x2x
0,25
+4x0
,5
4x7x
0,14
+ 2
x1,5
4x2x
0,18
10x0
,25
+ 2x
0,5
12x0
,25
15x0
,25
+ 4x
0,5
nx2x
0,25
4x2x
0,25
+ 2
x1
5x2x
0,25
+ 2
x0,5
12x(
2x0,
18)
flessibile dinamica limitata flexible, conditionally capable for drag chains
cara
tter
istic
hepr
oper
ties
per uso in catena capable for drag chains
x x x x x x x x x x x x x x x x x x x x
schermato shield
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
cUL-approvato cUL-approved
resistente agli oli resistant to oil
x x x x x x x x x x x x x x x x x x x x
autoestinguente flame-retardant
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
privo di alogeni halogen-free
x x x x x x x x x x x x x x x x x x x x
requisiti normali normal requirement
appl
icaz
ione
appl
ikat
ion
requisiti aumentati increased requirement
requisiti elevati high requirement
x x x x x x x x x x x x x x x x x x x x
requisiti estremi extreme requirement
per sistemi SIEMENS e.g. for system SIEMENS
sist
emi
syst
em
x x x x x x x x x x x x x x x
per sistemi BOSCH e.g. for system BOSCH
x x x x x
per sistemi NDRAMAT e.g. for system INDRAMAT
x x x x x x
per sistemi BALDOR e.g. for system BALDOR
x x
per sistemi FANUC e.g. for system FANUC
per sistemi FRABA e.g. for system FRABA
x
per sistemi HEIDENHAIN e.g. for system Heidenhain
x x x x x x x x x x x x
per sistemi LENZE e.g. for system LENZE
05
KA
WE
FL
EX
®
54
xx
0
5.0
4.0
1
54
xx
0
5.0
4.0
2
54
xx
0
5.0
4.0
1
54
xx
0
5.0
4.0
2
54
xx
0
5.0
4.0
1
54
xx
0
5.0
4.0
2
54
xx
0
5.0
4.0
1
54
xx
0
5.0
4.0
2
54
xx
0
5.0
4.0
1
54
xx
0
5.0
4.0
2
54
xx
0
5.0
4.0
1
56
xx
0
5.0
4.0
3
05
.04
.15
.01
05
.04
.15
.02
05
.04
.15
.03
05
.04
.15
.04
44
92
SK
-C-P
UR
44
96
SK
-C-P
UR
54
02
SK
-C-P
UR
54
04
SK
-C-P
UR
54
08
SK
-C-P
UR
54
12
SK
-C-P
UR
54
16
SK
-C-P
UR
54
21
SK
-C-P
UR
54
24
SK
-C-P
UR
54
29
SK
-C-P
UR
54
33
SK
-C-P
UR
54
36
SK
-C-P
UR
54
40
SK
-C-P
UR
54
44
SK
-C-P
UR
54
48
SK
-C-P
UR
54
64
SK
-C-P
UR
54
69
SK
-C-P
UR
54
72
SK
-C-P
UR
54
77
SK
-C-P
UR
54
80
SK
-C-P
UR
54
82
SK
-C-P
UR
54
84
SK
-C-P
UR
54
88
SK
-C-P
UR
54
93
SK
-C-P
UR
54
96
SK
-C-P
UR
56
10
SK
-PU
R
56
15
SK
-PU
R
56
20
SK
-PU
R
56
30
SK
-C-P
UR
Se
rvo
Dri
ve
Q
C-P
VC
UL
/CS
A
Se
rvo
Dri
ve
Q F
LE
X
C-P
VC
UL
/CS
A
Se
rvo
Dri
ve
Q S
K-C
-
PU
R U
L/C
SA
Se
rvo
Dri
ve
Q P
lus
SK
- C
-PU
R U
L/C
SA
form
azio
nedi
men
sion
4x2x
0,38
+ 4
x0,5
9x0,
5
4x0,
14) +
4x2
x0,1
4 +
4 x
0,5
10x0
,14
+ 2x
0,5
10x0
,14
+ 4x
0,5
15x0
,14
+ 4x
0,5
3x2x
0,14
+ 2
x0,5
3x(2
x0,1
4) +
2x(
0,5)
3x(2
x0,1
4) +
2x1
3x(2
x0,1
4) +
4x0
,14
+ 2x
0,5
3x(2
x0,1
4)+4
x0,1
4+4x
0,22
+2x0
,5
3x(2
x0,1
4) +
3x2
x0,2
5
4x2x
0,14
4x2x
0,25
+ 4
x0,2
5
4x2x
0,25
+ 4
x0,5
10x0
,25
+ 2x
0,5
12x0
,22
15x0
,25
+ 4x
0,5
nx2x
0,25
4x2x
0,25
+ 2
x1
4x2x
0,25
+2x0
,5
5x2x
0,25
+ 2
x0,5
12x(
2x0,
25)
4x2x
0,38
+ 4
x0,5
9x0,
5
3x(2
x0,1
4)+1
x(2x
0,5)
3x(2
x0,1
4)+1
x(3x
0,14
)
4x(2
x014
) + 1
x(2x
1)
5G0,
5
2X2X
0,22
(AW
G24
)
2X2X
0,22
(AW
G24
)
2x2x
0,15
(AW
G26
)+1x
2x0,
38(A
WG
22)
2x2x
0,20
(AW
G24
)+1x
2x0,
38(A
WG
22)
flessibile dinamica limitata flexible, conditionally capable for drag chains
cara
tter
istic
hepr
oper
ties
x
per uso in catena capable for drag chains
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
schermato shield
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
cUL-approvato cUL-approved
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
resistente agli oli resistant to oil
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
autoestinguente flame-retardant
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
privo di alogeni halogen-free
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
requisiti normali normal requirement
appl
icaz
ione
appl
ikat
ion
requisiti aumentati increased requirement
x x x x
requisiti elevati high requirement
x x x x x x x x x x x x x x x x x x x x x x x x x x x
requisiti estremi extreme requirement
per sistemi SIEMENS e.g. for system SIEMENS
sist
emi
syst
em
x x x x x x x x x x x x x x x x x x x
per sistemi BOSCH e.g. for system BOSCH
x x x x
per sistemi NDRAMAT e.g. for system INDRAMAT
x x x x
per sistemi BALDOR e.g. for system BALDOR
x
per sistemi FANUC e.g. for system FANUC
per sistemi FRABA e.g. for system FRABA
per sistemi HEIDENHAIN e.g. for system Heidenhain
x x x x x x x
per sistemi LENZE e.g. for system LENZE
x x x x
cavi unipolari schermati e non schermati di potenza per applicazioni mobili con requisitimeccanici normali. Adatti per impiego in catena portacavi, utenze mobili e nel campodella robotica in ambiente sia bagnato che asciutto.
s a single core shielded and unshielded power and control cable for normal require-ments in drag chain application, for motion drive systems and in the field of robotic tech-nology in dry and wet rooms.
• ritardante la fiamma, bassa aderenza e autoestinguente• ampiamente resistente all'azione di grassi, lubrificanti, liquidi refrigeranti• approvato UL/CSA 600V, la posa in parallelo con altri cavi 600V è permessa• privo di silicone e di sostanze che possono danneggiare la vernice
• flame-resistant, low-adhesion and self-extinguishing• largely resistant to oil, grease, coolant fluids and lubricants• due to 600 V UL/CSA approval parallel laying with other 600 V cables is permitted• free from lacquer damaging substances & silicone (during production)
• conforme a RoHS• conforme alla 2006/95/EC-("Direttiva Bassa Tensione") CE• disponibile nella versione multipolare capitolo 04.02.01• versioni speciali, altre formazioni e colori della guaina e dei conduttori su richiesta
• conform to RoHS• conform to 2006/95/EC-Guideline• alternative available as multi core version see chapter 04.02.01• e are pleased to produce special versions, other dimensions, core and jacket co-
lours on request.
trefolo in rame rosso conductor material bare copper strandconforme a DIN VDE 0295 cl. 6, IEC 60228 cl.6 conductor class acc. to DIN VDE 0295 cl. 6 resp. IEC 60228 cl. 6PVC core insulation PVCnero o G/V core identification BK or GNYEprotezione sotto lo schermo protection against contact with overall shield present under the screen
materiale conduttoreclasse conduttoreisolamento conduttoredistinzione dei conduttoriprotezione da contatto
disponibile versione con o senza schermatura vedere ta-bella a destra
shield with and without overall shield optional available Look atthe table of the right side
materiale guaina esterna PVC outer sheath PVCcolore guaina nero (RAL 9005) sheath colour black (RAL 9005)marcatura opz. printing optional
tensione nominale UL/CSA 600 V rated voltage UL/CSA 600 Vtensione di prova 4000 V testing voltage 4000 Vresistenza del conduttore a +20°C secondo DIN VDE 0295 cl.6, IEC 60228 cl.6 conductor resistance at +20 °C acc. to DIN VDE 0295 cl. 6 resp. IEC 60228
cl. 6resistenza d'isolamento min. 20 MΩ x km insulation resistance min. 20 MΩ x kmportata corrente secondo DIN VDE current carrying capacity acc. DIN VDEraggio min. curv. p. fissa 5 x d min. bending radius fixed 5 x draggio min. curv. p. mobile 7,5 x d min. bending radius moved 7,5 x dtemp. eser. fissa min/max -30°C / +80°C operat. temp. fixed min/max -30°C / + 80°Ctemp. eser. mobile min/max -5 °C / +70 °C operat. temp. moved min/max -5°C / + 70°Ccomportamento al fuoco secondo VDE 0482-332-2-1 DIN EN 60332-2-1, ritar-
dante la fiammaburning behavior acc. to VDE 0482-332-2-1 resp. DIN EN 60332-2-1, fla-
me-retardantstandard secondo DIN VDE 0207, 0250, 0293, 0295 e 0812 IEC standard acc. to DIN VDE 0207, 0250, 0293, 0295 and 0812 resp.
IECapprovazioni UL 80 °C, 600 V, cULus 80 °C, 600 V approvals UL 80 °C, 600 V, cULus 80 °C, 600 V
.
art. n
Item no.
n. conduttori & sezio-ne
dimensionn x mm²
peso ramekg/km
Cu indexkg/km
peso nettokg/kmweightkg/km
1503955 1 X 10 100,0 180,01503956 1 X 16 160,0 245,01503957 1 X 25 250,0 365,01503958 1 X 35 350,0 485,01503959 1 X 50 500,0 665,01503968 1 X 70 700,0 886,01503969 1 X 95 950,0 1.164,01503970 1 X 120 1.200,0 1.498,01503971 1 X 150 1.500,0 1.910,0
1504092 1 G 6 57,6 108,01504199 1 G 10 100,0 180,01504085 1 G 16 160,0 245,01504200 1 G 25 250,0 365,01504086 1 G 35 350,0 485,01504087 1 G 50 500,0 665,01504201 1 G 70 700,0 886,01504088 1 G 95 950,0 1.164,01504202 1 G 120 1.200,0 1.498,01504203 1 G 150 1.500,0 1.910,0
.
art. n
Item no.
n. conduttori & sezio-ne
dimensionn x mm²
peso ramekg/km
Cu indexkg/km
peso nettokg/kmweightkg/km
1503960 1 X 10 121,8 230,01503961 1 X 16 184,6 300,01503962 1 X 25 278,3 415,01503963 1 X 35 405,0 610,01503964 1 X 50 564,2 815,01503972 1 X 70 765,0 976,01503973 1 X 95 1.049,0 1.301,01503974 1 X 120 1.316,0 1.639,01503975 1 X 150 1.630,0 2.070,0
1504204 1 G 10 121,8 230,01504205 1 G 16 184,6 300,01504206 1 G 25 278,3 415,01504208 1 G 50 564,2 815,01504207 1 G 35 405,0 610,01504209 1 G 70 765,0 976,01504210 1 G 95 1.049,0 1.301,01504211 1 G 120 1.316,0 1.639,01504212 1 G 150 1.630,0 2.070,0
cavo schermato di alimentazione in applicazioni EMC per il collegamento di servomotoriper requisiti elettrici e meccanici elevati. Idoneo per impiego in catene portacavo con di-namiche veloci, in utenze mobili, nel campo della robotica e in automatismi in generale.
high flexible power cable for high electrical and mechanical requirements for EMC-com-patible connecting in industrial surrounding. Suitable for drag chain applications, movingdrive systems on machine tools, transfer lines, manufacturing plants as well as in dryand humid rooms.
• conform to DESINA (guaina nera)• approvato UL/CSA• ritardante la fiamma,privo di alogeni, bassa aderenza e bassa abrasione• ampiamente resistente al grasso, ai liquidi refrigeranti e ai lubrificanti• resistente agli oli secondo VDE 0473-811-404• privo di silicone in fase di produzione• privo CFC secondo DIN 472815/IEC 60754-1• La posa in parallelo con altri cavi 600V è consentita grazie a 600V UL.
• conform to DESINA (black outer sheath)• UL/CSA approved• flame-retardant, halogen-free, low adhesion and low abrasion• largely resistant to grease, coolant fluids and lubricants• resistant to oil acc. to VDE 0473-811-404• silicone-free during production• CFC-free acc. to DIN 472815/IEC 60754-1• with the 600 V UL approval, the parallel laying with other cables that are equally ap-
proved for 600 V, is permitted.
• conforme a RoHS• di lunga durata, ottimo rapporto costo/valore• versioni speciali, altre formazioni e colori di guaina e conduttori su richiesta.• ridimensionati in spazio e peso
• conform to RoHS• very long lifetime, optimal cost-value ratio• e are pleased to produce special versions, other dimensions, core and jacket co-
lours on request.• space- and weight-saving
materiale conduttore trefolo in rame rosso conductor material bare copper strandclasse conduttore secondo DIN VDE 0295 cl. 6 e IEC 60228 cl. 6 conductor class acc. to DIN VDE 0295 cl. 6 and IEC 60228 cl. 6isolamento conduttore PELON® TPE core insulation PELON® TPEdistinzione dei conduttori neri con marc. WWW, VV, U e 1 x G/V core identification BK with print WWW, VV, U and 1 x GNYEmateriale guaina esterna PUR outer sheath PURcolore guaina arancio, RAL 2003 / nero, RAL 9005 sheath colour orange, RAL 2003 / black, RAL 9005marcatura secondo standard TKD printing acc. to actual TKD-Printnorm
tensione nominale Uo/U 1.000 V secondo cUL; Uo/U 600/1.000 V secondoVDE
rated voltage Uo/U 1.000 V acc. to cUL; Uo/U 600/1.000 V acc. toVDE
tensione di prova cond/cond: 4.000 V testing voltage core/core: 4.000 Vresistenza del conduttore at +20 °C acc. to DIN VDE 0295 cl. 6 and IEC 60228 cl.
6conductor resistance at +20 °C acc. to DIN VDE 0295 cl. 6 and IEC 60228 cl.
6resistenza d'isolamento a +20 °C ≥ 20 MΩ x km insulation resistance at +20 °C ≥ 20 MΩ x kmportata corrente secondo DIN VDE 0100 current carrying capacity acc. to DIN VDE 0100raggio min. curv. p. fissa 5 x d min. bending radius fixed 5 x draggio min. curv. p. mobile 7,5 x d min. bending radius moved 7,5 x dtemp. eser. fissa min/max -50°C/+80°C operat. temp. fixed min/max -50 °C / +80 °Ctemp. eser. mobile min/max -30°C/+80°C operat. temp. moved min/max -30 °C / +80 °Ccomportamento al fuoco secondo VDE 0482-332-2-1 e DIN EN 60332-2-1, ritar-
dante la fiammaburning behavior acc. to VDE 0482-332-2-1 and DIN EN 60332-2-1, fla-
me-retardantstandard acc. to DIN VDE 0207, 0250, 0293, 0295, 0472, 0473,
0812 resp. IECstandard acc. to DIN VDE 0207, 0250, 0293, 0295, 0472, 0473,
0812 resp. IECapprovazioni UL 80°C, 1.000 V, cULus 80°C, 1.000 V approvals UL 80°C, 1.000 V, cULus 80°C, 1.000 V
.
art. n
Item no.
n. conduttori &sezione
dimensionn x mm²
diametromm
outer-Ømm
peso ramekg/km
Cu indexkg/km
peso nettokg/kmweightkg/km
1504457 4 G 1,5 9,2 60,0 118,01504458 4 G 2,5 10,5 100,0 178,01504459 4 G 4 11,8 160,0 265,01504460 4 G 6 14,2 240,0 304,01504461 4 G 10 17,7 400,0 612,01504462 4 G 16 21,9 640,0 870,0
.
art. n
Item no.
n. conduttori &sezione
dimensionn x mm²
diametromm
outer-Ømm
peso ramekg/km
Cu indexkg/km
peso nettokg/kmweightkg/km
1504463 4 G 25 26,0 1.000,0 1.440,01504464 4 G 35 30,2 1.400,0 1.930,01504465 4 G 50 34,3 2.000,0 2.460,01504466 4 G 70 40,7 2.800,0 0,01504467 4 G 95 45,8 3.800,0 0,0
cavo schermato di alimentazione per applicazioni EMC anche con 2, 3 o 4 conduttori dicontrollo. Adatto per il collegamento di convertitori di frequenza a motori, per impiego incatene portacavo con requisiti dinamici, elettrici e meccanici elevati; in macchine auto-matiche, macchine utensili, nel campo della robotica e in automatismi in generale. Adat-to sia in ambienti asciutti che bagnati.
shielded, low capacity power cable, also with 2, 3 resp. 4 control cores for temperaturesensors or brake for EMC-compatible connecting between drives and frequency conver-ter for high requirements in drag chain applications, moving drive systems, in the field ofrobotic technology, in manufacturing plants as well as in dry and humid rooms.
• conforme a DESINA, approvato UL/CSA• ritardante la fiamma, senza alogeni, bassa aderenza e bassa abrasione• ampiamente resistente all'azione di grassi, lubrificanti, liquidi refrigeranti• resistente agli oli secondo VDE 0472 parte 803 test B• privo di silicone• CFC-free secondo DIN 472815 / IEC 60754-1• dimensioni e pesi ridotti• grazie a all'approvazione 600V/1000V UL/CSA la posa in parallelo di altri cavi con
stessa tensione è consentita
• conform to DESINA, UL/CSA approved• flame-retardant, UV-resistant, halogen-free, low adhesion and low abrasion• largely resistant to grease, coolant fluids and lubricants• resistant to oil acc. to VDE 0473-811-404• silicone-free• CFC-free DIN 472815/IEC 60754-1• with the 600 V UL approval, the parallel laying with other cables that are
equally ap-proved for 600 V , is permitted
• conforme a RoHS• ottimo rapporto qualità-prezzo, lunga durata operativa• progettazione ottimale con diametri ridotti e pesi ridotti• versioni speciali, altre formazioni e colori della guaina e dei conduttori su richiesta
• conform to RoHS• very long lifetime, optimal cost-value ratio• platz- und gewichtssparend• e are pleased to produce special versions, other dimensions, core and jacket co-
lours on request.
materiale conduttore trefolo in rame rosso conductor material bare copper strandclasse conduttore conforme a DIN VDE 0295 cl. 6, IEC 60228 cl.6 conductor class acc. to DIN VDE 0295 cl. 6 resp. IEC 60228 cl. 6isolamento conduttore PELON®2 core insulation PELON®2distinzione dei conduttori cond. di alimentazone: neri con marcatura bianca U/L1/
C/L+; V/L2; W/L3/D/L- e G/V; cond. di controllo: 1 coppianero e bianco; 2 coppie neri con marcatura 5,6,7,8; ter-na: neri con marc. 1, 2, 3
core identification supply cores: BK with WH print U/L1/C/L+; V/L2; W/L3/D/L- and GNYE; control cores: 1-pair, BK and WH; 2-pair: BK with WH print 5, 6, 7, 8; triple: bk with wh nume-rals 1. 2, 3
schermatura coppie/terna di controllo con calza in rame stagnato shield control pairs resp. triple with tinned copper shieldcordatura totale conduttori ed elementi cordati insieme con riempitivo al-
tamente flessibileoverall stranding all cores and elements stranded together with high flexi-
ble fillerscalza in rame stagnato con copertura min. 85% shield copper braid tinned, opt. coverage appr. 85 %PUR , halogen free, autoestinguente outer sheath PUR, halogen-free, flame retardantarancio, RAL 2003 sheath colour orange, RAL 2003
totalemateriale guaina esternacolore guaina marcatura
si printing yes
tensione nominale cond. di alim./cond. di controllo Uo/U 600/1.000 V; UL &CSA: 1.000 V
rated voltage Power cores/control cores: Uo/U 600/1.000 V; UL &CSA: 1.000 V
tensione di prova cond./cond: 4kV; cond./schermo: 4kV testing voltage core/core: 4 kV; core/shield: 4 kVresistenza del conduttore a +20°C secondo DIN VDE 0295 cl.6, IEC 60228 cl.6 conductor resistance at +20 °C acc. to DIN VDE 0295 cl. 6 and IEC 60228 cl.
6resistenza d'isolamento a +20 °C ≥ 20 GΩ x km insulation resistance at +20 °C ≥ 20 GΩ x kmcapacità contattare il ns. u.t. capacity values on requestaltre caratteristiche accelerazione fino a 50 m/s² velocità fino a 300 m/min
corsa catena orizz.: ≤16mm² fino a 50 m /≥25mm² fino a20 m corsa catena verticale: max. 5 m
other characteristics accellerations up to 50 m/s² speeds up to 300 m/minpath length, horiz.: ≤ 16mm² up to 50 m /≥ 25mm² up to20 m path length, vertical: max. 5 m
raggio min. curv. p. fissa 4 x d - dopo installazione min. bending radius fixed 4 x d - after installationraggio min. curv. p. mobile 7,5 x D (≤16mm²) / 10 x D (≥25mm²) min. bending radius moved 7,5 x D (≤ 16 mm²) / 10 x D (≥ 25 mm²)temp. eser. fissa min/max -50 °C / +80 °C operat. temp. fixed min/max -50 °C / +80 °Ctemp. eser. mobile min/max -40 °C / +80 °C operat. temp. moved min/max -40 °C / +80 °Ccomportamento al fuoco in accordo a VDE 0482-332-2-1 e DIN IEC 60332-2-1,
autoestinguenteburning behavior acc. to VDE 0482-332-2-1 and DIN EN 60332-2-1, fla-
me-retardantapprovazioni UL 80°C, 1.000 V, cULus 80°C, 1.000 V, FT1 and VW1 approvals UL 80°C, 1.000 V, cULus 80°C, 1.000 V, FT1 and VW1
.
art. n
Item no.
n. conduttori & sezionen x mm²
dimensionn x mm²
diametromm
outer-Ømm
peso ramekg/km
Cu indexkg/km
peso nettokg/kmweightkg/km
1504266 4 G 1,5 9,2 90,0 163,01504267 4 G 2,5 10,6 135,0 233,0
1504268 4 G 4 11,9 205,0 314,01504269 4 G 6 14,7 296,0 437,01504270 4G 10 17,5 488,0 654,01504271 4 G 16 21,6 769,0 1.016,01504272 4 G 25 25,2 1.098,0 1.440,01504273 4 G 35 28,7 1.525,0 1.991,01504274 4 G 50 33,4 2.131,0 2.604,0
1504275 4 G 1,5 + (2 X 1,5) 11,7 163,5 251,01504276 4 G 2,5 + (2 X 1,5) 13,4 196,0 316,0
1504277 4 G 4 + (2 X 1,5) 14,9 260,5 408,01504278 4 G 6 + (2 X 1,5) 16,8 365,0 535,01504279 4 G 10 + (2 X 1,5) 19,9 560,0 755,01504280 4 G 16 + (2 X 1,5) 22,7 816,0 1.090,01504281 4 G 25 + (2 X 1,5) 26,3 1.172,0 1.570,01504282 4 G 35 + (2 X 1,5) 31,2 1.595,0 2.073,01504283 4 G 50 + (2 X 1,5) 34,7 2.214,0 2.800,0
.
art. n
Item no.
n. conduttori & sezionen x mm²
dimensionn x mm²
diametromm
outer-Ømm
peso ramekg/km
Cu indexkg/km
peso nettokg/kmweightkg/km
1504293 4 G 1 + 2 X (2 X 0,75) 12,0 130,0 203,01504284 4 G 1,5 + 2 X (2 X 0,75) 13,0 151,0 228,01504285 4 G 2,5 + 2 X (2 X 1) 14,8 213,9 343,01504286 4 G 4 + (2 X 1) + (2 X 1,5) 16,3 336,0 449,01504287 4 G 6 + (2 X 1) + (2 X 1,5) 18,6 438,0 572,01504288 4 G 10 + (2 X 1) + (2 X 1,5) 22,0 602,0 881,01504289 4 G 16 + (2 X 1) + (2 X 1,5) 25,5 834,0 1.155,01504290 4 G 25 + 2 X (2 X 1,5) 28,9 1.217,0 1.513,01504291 4 G 35 + 2 X (2 X 1,5) 31,4 1.640,0 1.969,01504292 4 G 50 + 2 X (2 X 2,5) 37,0 2.273,0 2.875,0
1504711 4 G 1,5 + (3 X 1) 11,6 163,5 213,01504712 4 G 2,5 + (3 X 1) 13,4 196,0 284,01504713 4 G 4 + (3 X 1) 14,8 260,5 366,0
1504714 4 G 6 + (3 X 1,5) 17,4 367,0 492,01504715 4 G 10 + (3 X 1,5) 20,3 563,0 717,01504716 4 G 16 + (3 X 1,5) 23,7 821,0 1.052,0
cavo schermato di alimentazione per applicazioni EMC anche con conduttori di control-lo. Adatto per il collegamento di convertitori di frequenza a motori, per impiego in cateneportacavo con requisiti dinamici e meccanici normali, elettrici elevati; in macchine auto-matiche, macchine utensili, nel campo della robotica e in automatismi in generale. Adat-to sia in ambienti asciutti che bagnati.
shielded, low capacity power cable with control cores for temperature sensors or brakefor EMC-compatible connecting between drives and frequency converter for normal re-quirements in drag chain applications, moving drive systems, in the field of robotic tech-nology and manufacturing plants. Suitable for use in dry and humid rooms.
• conforme a DESINA, approvato UL/CSA• ampiamente resistente all'azione di grassi, lubrificanti, liquidi refrigeranti• privo di silicone•• grazie a all'approvazione 600V/1000V UL/CSA la posa in parallelo di altri cavi con
stessa tensione è consentita
• conform to DESINA, UL/CSA approved• largely resistant to grease, coolant fluids and lubricants• silicone-free• with the UL approval, the parallel laying with other cables that are equally
ap-proved for 600 V , is permitted
• conforme a RoHS• conforme alla 2006/95/EC-("Direttiva Bassa Tensione") CE• ottimo rapporto qualità/prezzo• versioni speciali, altre pezzature, colori della guaina e dei conduttori su richiesta
• conform to RoHS• conform to 2006/95/EC-Guideline (CE marking)• optimal cost-value ratio• e are pleased to produce special versions, other dimensions, core and jacket co-
lours on request.
materiale conduttore trefolo in rame rosso conductor material bare copper strandclasse conduttore conforme a DIN VDE 0295 cl.6, IEC 60228 cl.6 conductor class super fine wires acc. to DIN VDE 0295 cl. 6 resp. IEC
60228 cl. 6isolamento conduttore PELON®2, PP core insulation PELON®2, PPdistinzione dei conduttori cond. di alimentazone: neri con marcatura bianca U/L1/
C/L+; V/L2; W/L3/D/L- & G/V; cond. di controllo:1 coppianero e bianco
core identification supply cores: BK w. WH print U/L1/C/L+; V/L2; W/L3/D/L- & GNYE; control cores: 1 pair, BK & WH
schermatura coppie di controllo con calza in rame stagnato shield control pair with tinned copper braidcordatura totale conduttori ed elementi cordati insieme con riempitivo al-
tamente flessibileoverall stranding cores & element stranded together with high flexible fil-
lerscalza in rame stagnato con copertura min. 85% shield copper braid tinned, opt. coverage 85 %PVC outer sheath PVC
totalemateriale guaina esternacolore guaina arancio, RAL2003 sheath colour orange, RAL 2003
tensione nominale cond. di alim./cond. di controllo Uo/U 600/1.000 V; UL &CSA: 1.000 V
rated voltage supply cores/control cores: Uo/U 600/1.000 V; UL &CSA: 1.000 V
tensione di prova 4 kV testing voltage 4 kVresistenza del conduttore a +20 °C secondo DIN VDE 0295 cl.6 e IEC 60228 cl.6 conductor resistance at +20 °C acc. to DIN VDE 0295 cl. 6 and IEC 60228 cl.
6resistenza d'isolamento a 20° C ≥ 20 GOhm x km insulation resistance at 20° C ≥ 20 GOhm x kmaltre caratteristiche accelerazione fino a 20 m/s²; velocità fino a 120 m/min;
corsa catena fino a 50 mother characteristics accellerations up to 20 m/s²; speeds up to 120 m/min;
path length: up to 50 mraggio min. curv. p. fissa 5 x d min. bending radius fixed 5 x draggio min. curv. p. mobile 10 x d min. bending radius moved 10 x dtemp. eser. fissa min/max -30 °C / +80 °C operat. temp. fixed min/max -30 °C / +80 °Ctemp. eser. mobile min/max -5 °C / +80 °C operat. temp. moved min/max -5 °C bis +80 °Ccomportamento al fuoco autoestinguente e ritardante la fiamma secondo IEC
60332-1; UL: VW1; CSA: FT1burning behavior self-extinguishing and flame-retardant acc. to IEC
60332-1; UL: VW1; CSA: FT1resistenza agli oli secondo ISO 6722, EN 60811-2-1 (solo oli minerali) resistant to oil acc. to ISO 6722, EN 60811-2-1 (only mineral oil)approvazioni UL 80°C, 1.000 V, cULus 80°C, 1.000 V approvals UL 80°C, 1.000 V, cULus 80°C, 1.000 V
.
art. n
Item no.
n. conduttori & sezionen x mm²
dimensionn x mm²
diametromm
outer-Ømm
peso ramekg/km
Cu indexkg/km
peso nettokg/kmweightkg/km
1504502 4 G 1,5 8,8 80,0 145,01504503 4 G 2,5 10,3 123,0 216,0
1504504 4 G 4 12,1 185,0 290,01504508 4 G 6 15,0 288,0 430,01504509 4 G 10 17,3 453,0 640,0
.
art. n
Item no.
n. conduttori & sezionen x mm²
dimensionn x mm²
diametromm
outer-Ømm
peso ramekg/km
Cu indexkg/km
peso nettokg/kmweightkg/km
1504505 4 G 1,5 + (2 X 1,5) 10,6 130,0 234,01504506 4 G 2,5 + (2 X 1,5) 12,0 175,0 302,0
1504507 4 G 4 + (2 X 1,5) 13,8 253,0 402,01504510 4 G 6 + (2 X 1,5) 16,5 341,0 525,01504511 4 G 10 + (2 X 1,5) 19,0 529,0 735,0
cavo schermato di alimentazione per applicazioni EMC anche con conduttori di control-lo. Adatto per il collegamento di convertitori di frequenza a motori, per posa fissa e perimpieghi flessibili senza sollecitazioni a trazione, per requisiti elettrici elevati; in macchi-ne automatiche e in automatismi in generale. Adatto sia in ambienti asciutti che bagnati.
shielded, low capacity power cable with control cores for temperature sensors or brakefor EMC-compatible connecting between drives and frequency converter for normalelectrical and mechanical requirements. Suitable for dry and humid rooms.
• conforme a DESINA, approvato UL/CSA• ampiamente resistente all'azione di grassi, lubrificanti e liquidi refrigeranti• privo di silicone• grazie a all'approvazione 600V/1000V UL/CSA la posa in parallelo di altri cavi constessa tensione è consentita
• conform to DESINA, UL/CSA approved• largely resistant to grease, coolant fluids and lubricants• silicone-free• with the V UL approval, the parallel laying with other cables that are equally
approved for 600 V , is permitted
• conforme a RoHS• conforme alla 2006/95/EC-("Direttiva Bassa tensione") CE• ottimo rapporto qualità/prezzo• versioni speciali, altre formazioni e colori della guaina e dei conduttori su richiesta
• conform to RoHS• conform to 2006/95/EC-Guideline (CE marking)• optimal cost-value ratio• e are pleased to produce special versions, other dimensions, core and jacket co-
lours on request.
materiale conduttore trefolo in rame rosso conductor material bare copper strandclasse conduttore conforme a DIN VDE 0295 cl.5, IEC 60228 cl.5 conductor class acc. to DIN VDE 0295 cl. 5 resp. IEC 60228 cl. 5isolamento conduttore PELON®2, PP core insulation PELON®2, PPdistinzione dei conduttori cond. di alimentazione: neri con marcatura bianca U/L1/
C/L+; V/L2; W/L3/D/L- e G/V; cond. di controllo: 1 coppianero e bianco; terna neri marc. 1, 2, 3
core identification supply cores: BK w. WH print U/L1/C/L+; V/L2; W/L3/D/L- & GNYE; control cores: 1 pair, BK & WH; triple: bkwith wh numerals 1. 2, 3
schermatura coppia/terna di controllo con calza in rame stagnato shield control pair resp.triple bundle with tinned copper shield
atura totale conduttori ed elementi cordati insieme con riempitivo al-tamente flessibile
overall stranding cores and pair resp. triple element stranded togetherwith high flexible fillers
calza in rame stagnato con copertura min.80% shield copper braid tinned, opt. coverage appr. 80 %PVC outer sheath PVC
atura totalemateriale guaina esternacolore guaina arancio, RAL2003 sheath colour orange, RAL 2003
tensione nominale cond. di alim./cond. di controllo: Uo/U 600/1.000 V; UL &CSA: 1.000 V
rated voltage supply cores/control cores: Uo/U 600/1.000 V; UL &CSA: 1.000 V
tensione di prova 4 kV testing voltage 4 kVresistenza del conduttore at +20 °C secondo DIN VDE 0295 cl. 5 e IEC 60228 cl.
5conductor resistance at +20 °C acc. to DIN VDE 0295 cl. 5 and IEC 60228 cl.
5resistenza d'isolamento a 20° C ≥ 20 GOhm x km insulation resistance at 20° C ≥ 20 GOhm x kmraggio min. curv. p. fissa 5 x d min. bending radius fixed 5 x draggio min. curv. p. mobile 10 x d min. bending radius moved 10 x dtemp. eser. fissa min/max -30 °C / +80 °C operat. temp. fixed min/max -30°C / +80°Ctemp. eser. mobile min/max -5 °C / +80 °C operat. temp. moved min/max -5°C / +80°Ccomportamento al fuoco autoestinguente e ritardante la fiamma secondo IEC
60332-1; UL: VW1; CSA: FT1burning behavior self-extinguishing and flame-retardant acc. to IEC
60332-1; UL: VW1; CSA: FT1resistenza agli oli secondo ISO 6722, EN 60811-2-1 (solo oli minerali) resistant to oil acc. to ISO 6722, EN 60811-2-1 (only mineral oil)altre caratteristiche - velocità cat. autoportante: max. 30 m/min. - corsa (TL):
max. 5 m - accelerazione: max. 2 m/s² - min. raggio dicurvatura im posa m.: 15 x d - cicli curvatura: > 100.000
other characteristics - speed self-supporting: max. 30 m/min. - traverse length(TL): max. 5 m - accelaration: max. 2 m/s² - min. ben-ding radius moved: 15 x d - bending cycles: > 100.000
approvazioni UL 80°C, 1.000 V, cULus 80°C, 1.000 V approvals UL 80°C, 1.000 V, cULus 80°C, 1.000 V.
art. n
Item no.
n. conduttori & sezionen x mm²
dimensionn x mm²
diametromm
outer-Ømm
peso ramekg/km
Cu indexkg/km
peso nettokg/kmweightkg/km
1504496 4 G 1,5 8,5 77,0 143,01504497 4 G 2,5 10,0 120,0 213,0
1504498 4 G 4 11,8 182,0 287,01504512 4 G 6 14,0 285,0 424,01504513 4 G 10 17,3 449,0 631,0
1504499 4 G 1,5 + (2 X 1,5) 10,2 126,5 231,01504500 4 G 2,5 + (2 X 1,5) 11,8 171,4 298,0
1504501 4 G 4 + (2 X 1,5) 13,4 249,5 398,01504514 4 G 6 + (2 X 1,5) 15,7 337,2 517,01504515 4 G 10 + (2 X 1,5) 19,0 525,3 720,0
.
art. n
Item no.
n. conduttori & sezionen x mm²
dimensionn x mm²
diametromm
outer-Ømm
peso ramekg/km
Cu indexkg/km
peso nettokg/kmweightkg/km
1504652 4 G 1,5 + (3 X 1) 11,4 135,0 214,01504653 4 G 2,5 + (3 X 1) 12,7 178,0 282,01504654 4 G 4 + (3 X 1) 14,2 254,0 378,0
1504655 4 G 6 + (3 X 1,5) 16,6 379,0 528,01504656 4 G 10 + (3 X 1,5) 18,8 565,0 758,0
cavo schermato ibrido a bassa capacità per posa fissa e per impieghi flessibili senzasollecitazioni a trazione, adatto per il collegamento tra servoazionamenti e servomotoria feedback digitale con comunicazione integrata all'interno del cavo motore, per requisitielettrici elevati; in macchine automatiche, in automatismi in generale e per zone di movi-mentazione anche in ambienti umidi e bagnati.
shielded, low capacity hybrid cable for applications with fixed or conditionally flexible in-stallation in electrical drive technology, as a connection cable servo controler and motor,in assembly and insertion machines, especially for the wet area of transfer lines or ma-chine tools.
• for HIPERFACE DSL® motor-feedback-systems - HIghPERformance InterFACE Digi-tal Servo Link
• ampiamente resistente al grasso, ai liquidi refrigeranti e ai lubrificanti• resistente agli oli secondo DIN EN 60811-2-1 (solo oli minerali)• privo di silicone (in produzione)• ottimizzato, spazio e peso ridotti• grazie a all'approvazione 600V/1000V UL/CSA la posa in parallelo di altri cavi con
stessa tensione è consentita
• for HIPERFACE DSL® motor-feedback-systems - HIghPERformance InterFACE Digi-tal Servo Link
• largely resistant to grease, coolant fluids and lubricants• resistant to oil acc. to DIN EN 60811-2-1 (only mineral oil)• silicone-free (by )• space and weight saving• with the V UL approval, the parallel laying with other cables that are equally
ap-proved for 600 V , is permitted• conform to DESINA
• conforme a RoHS• conforme a 2006/95/EC-Guideline (CE marking)• versioni speciali, altre formazioni e colori di guaina e conduttori su richiesta• HIPERFACE DSL® è un marchio registrato di SICK AG
• conform to RoHS• conform to 2006/95/EC-Guideline (CE marking)• e are pleased to produce special versions, other dimensions, core and jacket co-
lours on requestHIPERFACE DSL® is a registered trademark of SICK AG
materiale conduttore trefolo in rame rosso, cond.class: secondo DIN VDE0295 Cl. 5 resp. IEC 60228 cl. 5
conductor material bare copper strand, cond.class: acc. to DIN VDE 0295Cl. 5 resp. IEC 60228 cl. 5
classe conduttore secondo DIN VDE 0295 class 5 resp. IEC 60228 cl. 5 conductor class acc. to DIN VDE 0295 class 5 resp. IEC 60228 cl. 5isolamento conduttore PELON®2 core insulation PELON®2distinzione dei conduttori core identification BK with WH print U/L1/C/L+;V/L2;W/L3/D/L- & 1core
GNYE; signalpair: WH,BU, controlpair (optional): BK w.WH numerals 5+6
schermatura shield signal pair/control pair: each aluminium clad foil; copperbraid tinned
neri con marc. U/L1/C/L+;V/L2;W/L3/D/L- & 1 cond G/V;coppia: Bia,Blu, cond contr. (optional): neri marc. bianco5+6
conduttori ed elementi cordati insieme overall stranding cores & elements stranded togethercalza in rame stagnato, copertura 85% shield copper braid tinded, coverage ca. 85%PVC outer sheath PVC
cordatura totaleatura totale
materiale guaina esternacolore guaina arancio, RAL 2003 sheath colour orange, RAL 2003
tensione nominale potenza & conduttori di controllo: IEC: 0,6/1kV; UL/CSA:1kV; segnale coppia max. 300V
rated voltage power- & control cores: IEC: 0,6/1kV; UL/CSA: 1kV; si-gnal pair: max. 300V
tensione di prova potenza & cond. di controllo: 4 kV, segnale coppia: 1kV testing voltage power- & control cores: 4 kV, signal pair: 1 kVresistenza del conduttore a +20 °C secondo DIN VDE 0295 cl. 5 ; IEC 60228 cl. 5 conductor resistance at +20 °C acc. to DIN VDE 0295 cl. 5 resp. IEC 60228
cl. 5resistenza d'isolamento a +20 °C ≥ 20 MΩ x km insulation resistance at +20 °C ≥ 20 MΩ x kmportata corrente secondo DIN VDE current carrying capacity acc. to DIN VDEimpedenza caratteristica coppia di segnale: circa 100 Ohm characteristic impedance signal pair: approx. 100 Ohmvelocitá trasmissione dati 9.375 Mbaud fino a 100 m transfer rate 9.375 Mbaud until 100 mraggio min. curv. p. fissa 5 x d min. bending radius fixed 5 x draggio min. curv. p. mobile 15 x d min. bending radius moved 15 x dtemp. eser. fissa min/max -40°C/+80°C operat. temp. fixed min/max -40 °C / +80 °Ctemp. eser. mobile min/max -5°C/+80°C operat. temp. moved min/max -5 °C / +80 °Ccomportamento al fuoco ritardante la fiamma secondo IEC 60332-1-2, FT1, VW-1 burning behavior flame-retardant acc. to IEC 60332-1-2, FT1, VW-1approvazioni UL/CSA - cURus 1.000 / 300V, 80°C approvals UL/CSA - cURus 1.000 / 300V, 80°C
.
art. n
Item no.
n. conduttori & sezionen x mm²
dimensionn x mm²
diametromm
outer-Ømm
peso ramekg/km
Cu indexkg/km
peso nettokg/kmweightkg/km
identificazione conduttori
core identification
1504861 4 G 1,5 + (2 X AWG 22/7)C 11,6 116,0 198,0 U, V, W, GNYE, (WH+BU)1504862 4 G 2,5 + (2 X AW G22/7)C 12,8 168,0 269,0 U, V, W, GNYE, (WH+BU)1504863 4 G 4 + (2 X AWG 22/7)C 14,3 235,0 343,0 U, V, W, GNYE, (WH+BU)
1505231 4 G 0,5 + (2 X 0,34)C + (2 X AWG 26/7)C 9,4 77,0 123,0 U, V, (5+6), W, GNYE, (WH+BU)1505232 4 G 0,75 + (2 X 0,34)C + (2 X AWG 26/7)C 9,9 97,0 138,0 U, V, (5+6), W, GNYE, (WH+BU)
1505233 4 G 1 + (2 X 0,75)C + (2 X AWG 22/7)C 11,6 129,0 208,0 U, V, (5+6), W, GNYE, (WH+BU)1505234 4 G 1,5 + (2 X 0,75)C + (2 X AWG 22/7)C 12,8 152,0 248,0 U, V, (5+6), W, GNYE, (WH+BU)
1504864 4 G 1,5 + (2 X 1)C + (2 X AWG 22/7)C 13,2 164,0 256,0 U, V, (5+6), W, GNYE, (WH+BU)1504865 4 G 2,5 + (2 X 1)C + (2 X AWG 22/7)C 14,5 208,0 313,0 U, V, (5+6), W, GNYE, (WH+BU)1504866 4 G 4 + (2 X 1)C + (2 X AWG 22/7)C 16,2 276,0 407,0 U, V, (5+6), W, GNYE, (WH+BU)1505235 4 G 6 + (2 X 1)C + (2 X AWG 22/7)C 18,6 364,0 538,0 U, V, (5+6), W, GNYE, (WH+BU)
1505236 4 G 10 + (2 X 1,5)C + (2 X AWG 22/7)C 21,6 571,0 752,0 U, V, (5+6), W, GNYE, (WH+BU)1505237 4 G 16 + (2 X 1,5)C + (2 X AWG 22/7)C 24,6 833,0 1.005,0 U, V, (5+6), W, GNYE, (WH+BU)
.
cavo schermato ibrido a bassa capacità per impieghi dinamici, adatto per il collega-mento tra servoazionamenti e servomotori a feedback digitale con comunicazione inte-grata all'interno del cavo motore, per requisiti elettrici elevati; in macchine automatiche,in automatismi in generale e per zone di movimentazione anche in ambienti umidi e ba-gnati.
shielded, low capacity hybrid cable for drag chain applications in electrical drive techno-logy, as a connection cable servo and motor, in assembly and insertion machi-nes, especially for the wet area of transfer lines or machine tools.
• per HIPERFACE DSL® motor-feedback-systems - HIghPERformance InterFACE Digi-tal Servo Link
• ampiamente resistente al grasso, ai liquidi refrigeranti, ai lubrificanti• resistente agli oli secondo DIN EN 60811-2-1• privo di silicone (in produzione)• ottimizzato diametri e pesi ridotti• resistente agli UV, privo di alogeni, bassa abrasione• grazie a all'approvazione 600V/1000V UL/CSA la posa in parallelo di altri cavi con
stessa tensione è consentita• conforme a DESINA
• for HIPERFACE DSL® motor-feedback-systems - HIghPERformance InterFACE Digi-tal Servo Link
• largely resistant to grease, coolant fluids and lubricants• resistant to oil acc. to DIN EN 60811-2-1• silicone-free (by )• space and weight saving• UV-resistant, halogen-free, low abrasion• with the V UL approval, the parallel laying with other cables that are equally ap-
proved for 600 V , is permitted• conform to DESINA
• conforme a RoHS• conform a 2006/95/EC-Guideline (CE marking)• versioni speciali, altre formazioni e colori di guaina e conduttori su richiesta• HIPERFACE DSL® è un marchio registrato di SICK AG
• conform to RoHS• conform to 2006/95/EC-Guideline (CE marking)• e are pleased to produce special versions, other dimensions, core and jacket co-
lours on request.• HIPERFACE DSL® is a registered trademark of SICK AG
materiale conduttore trefolo in rame rosso conductor material bare copper strandclasse conduttore secondo DIN VDE 0295 Cl. 6 col. 4 resp. IEC 60228 cl.
6 col. 4conductor class acc. to DIN VDE 0295 Cl. 6 col. 4 resp. IEC 60228 cl. 6
col. 4isolamento conduttore PELON®2 core insulation PELON®2distinzione dei conduttori neri con marc. U/L1/C/L+;V/L2;W/L3/D/L- & 1 cond G/V;
coppia: Bia,Blu, cond contr. (optional): neri marc. bianco5+6
core identification BK with WH print U/L1/C/L+;V/L2;W/L3/D/L- & 1coreGNYE; signalpair: WH,BU, controlpair (optional): BKwith WH numerals 5+6
schermatura coppia di segnale/coppia di controllo: ciascuna con fo-glio di alluminio; calza in rame stagnato
shield signal pair/control pair: each aluminium clad foil; copperbraid tinned
cordatura totale conduttori ed elementi cordati insieme overall stranding cores & elements stranded togethercordatura totale calza in rame stagnato, copertura min. 85% shield copper braid tinded, coverage approx. 85%materiale guaina esterna PUR outer sheath PURcolore guaina orange, RAL 2003 sheath colour orange, RAL 2003
tensione nominale cond. di alimentazione e controllo: IEC: 0,6/1kV; UL/CSA: 1kV; coppia segnale: max. 300V
rated voltage power- & control cores: IEC: 0,6/1kV; UL/CSA: 1kV; si-gnal pair: max. 300V
tensione di prova cond. di alimentazione e controllo: 4 kV, coppia segnale:1 kV
testing voltage power- & control cores: 4 kV, signal pair: 1 kV
resistenza del conduttore a +20 °C secondo DIN VDE 0295 cl. 6 ; IEC 60228 cl. 6 conductor resistance at +20 °C acc. to DIN VDE 0295 cl. 6 resp. IEC 60228cl. 6
resistenza d'isolamento a +20 °C ≥ 20 MΩ x km insulation resistance at +20 °C ≥ 20 MΩ x kmportata corrente secondo DIN VDE current carrying capacity acc. to DIN VDEimpedenza caratteristica coppia segnale: circa 100 Ohm characteristic impedance signal pair: approx. 100 Ohmvelocitá trasmissione dati 9.375 Mbaud fino a 100 m transfer rate 9.375 Mbaud until 100 maltre caratteristiche - velocità autoportante: max. 5 m/s - corsa (TL): max. 25
m - accelerazione: max. 10 m/s² - cicli curvatura: > 5 mioother characteristics - speed self-supporting: max. 5 m/s - traverse length
(TL): max. 25 m - acceleration: max. 10 m/s² - bendingcycles: > 5 mio
raggio min. curv. p. fissa 5 x d min. bending radius fixed 5 x draggio min. curv. p. mobile 7,5 x d < 10m corsa | 10 x d ≥ 10m corsa min. bending radius moved 7,5 x d < 10m TL | 10 x d ≥ 10m TLtemp. eser. fissa min/max -50°C / +80°C operat. temp. fixed min/max -50°C / +80°Ctemp. eser. mobile min/max -40 °C / +80 °C operat. temp. moved min/max -40 °C / +80 °Ccomportamento al fuoco ritardante la fiamma secondo IEC 60332-1-2, FT1, VW-1 burning behavior flame-retardant acc. to IEC 60332-1-2, FT1, VW-1approvazioni UL/CSA - cURus 1.000 / 300V, 80°C approvals UL/CSA - cURus 1.000 / 300V, 80°C
.
art. n
Item no.
n. conduttori & sezionen x mm²
dimensionn x mm²
diametromm
outer-Ømm
peso ramekg/km
Cu indexkg/km
peso nettokg/kmweightkg/km
identificazione conduttori
core identification
1504867 4 G 1,5 + (2 X AWG 22/19)C 11,6 116,0 194,0 U, V, W, GNYE, (WH+BU)1504868 4 G 2,5 + (2 X AWG 22/19)C 12,8 168,0 253,0 U, V, W, GNYE, (WH+BU)1504869 4 G 4 + (2 X AWG 22/19)C 14,3 235,0 332,0 U, V, W, GNYE, (WH+BU)
1505238 4 G 0,5 + (2 X 0,34)C + (2 X AWG 26/19)C 9,3 77,0 127,0 U, V, (5+6), W, GNYE, (WH+BU)1505239 4 G 0,75 + (2 X 0,34)C + (2 X AWG 26/19)C 9,9 98,0 142,0 U, V, (5+6), W, GNYE, (WH+BU)
1505240 4 G 1 + (2 X 0,75)C + (2 X AWG 22/19)C 11,6 133,0 212,0 U, V, (5+6), W, GNYE, (WH+BU)
1505241 4 G 1,5 + (2 X 0,75)C + (2 X AWG 24/19)C 11,8 152,0 230,0 U, V, (5+6), W, GNYE, (WH+BU)1505242 4 G 1,5 + (2 X 0,75)C + (2 X AWG 22/19)C 12,8 155,0 269,0 U, V, (5+6), W, GNYE, (WH+BU)
1504870 4 G 1,5 + (2 X 1)C + (2 X AWG 22/19)C 13,2 166,0 250,0 U, V, (5+6), W, GNYE, (WH+BU)1505243 4 G 1,5 + (2 X 1,5)C + (2 X AWG 22/19)C 13,8 179,0 272,0 U, V, (5+6), W, GNYE, (WH+BU)
1504871 4 G 2,5 + (2 X 1)C + (2 X AWG 22/19)C 14,5 211,0 285,0 U, V, (5+6), W, GNYE, (WH+BU)1505244 4 G 2,5 + (2 X 1,5)C + (2 X AWG 22/19)C 15,1 230,0 220,0 U, V, (5+6), W, GNYE, (WH+BU)
1504872 4 G 4 + (2 X 1)C + (2 X AWG 22/19)C 16,2 274,0 390,0 U, V, (5+6), W, GNYE, (WH+BU)1505245 4 G 6 + (2 X 1)C + (2 X AWG 22/19)C 18,6 367,0 540,0 U, V, (5+6), W, GNYE, (WH+BU)
1505246 4 G 10 + (2 X 1,5)C + (2 X AWG 22/19)C 21,6 573,0 760,0 U, V, (5+6), W, GNYE, (WH+BU)1505247 4 G 16 + (2 X 1,5)C + (2 X AWG 22/19)C 24,6 836,0 1.020,0 U, V, (5+6), W, GNYE, (WH+BU)
.
cavo schermato a bassa capacità per collegamento di feedback, encoder, resolver, ta-chimetriche per connessioni in rispetto di EMC. Idoneo per uso in catene portacavi conrequisiti dinamici e meccanici leggeri.
as shielded, low capacity feedback, encoder, resolver, spedo sensor, signal & systemcables for EMC compatible connecting in and plant , as well as indrive and control technology, for normal electrical and light to medium mechanical requi-rements.
• conforme aDESINA (colore della guaina verde RAL 6018)• approvato cURus300V, 80°C• ritardante la fiamma, IEC 60332-1-2, F1, VW-1• ampiamente resistente al grasso, ai liquidi refrigeranti e ai lubrificanti• resistente agli oli, IEC 60811-404, (VDE 0473-811-404,solo oli minerali)• FCKW-free secondo DIN 472815/IEC60754-1• bassa aderenza, privo di silicone, ridotto in spazio e peso
• DESINA-conform (jacket colour green RAL 6018)• cURus approved 300V, 80°C• flame-retardant, IEC 60332-1-2, F1, VW-1• largely resistant to, grease, coolant fluids and lubricants• resistant to oil, IEC 60811-404, (VDE 0473-811-404, only mineral oil)• FCKW-free acc. to DIN 472815/IEC60754-1• low adhesion, silicone-free, space- and weight-saving
• conforme a RoHS• conform a 2006/95/EG guideline (CE marking)• ottimo rapporto qualità/prezzo
• conform to RoHS• conform to 2006/95/EG guideline (CE marking)• optimal cost-value ratio
materiale conduttore trefolo in rame rosso conductor material bare copper strandclasse conduttore secondo DIN VDE0295 cl.5 resp. IEC60228 cl.5 conductor class acc. to DIN VDE0295 cl.5 resp. IEC60228 cl.5isolamento conduttore PELON®2 core insulation PELON®2distinzione dei conduttori secondo specifiche del sistema (su richiesta) core identification acc. to system specification (on request)cordatura conduttori twistati in coppie o in strati stranding cores twisted to pairs or in layersschermatura tipo: D: schermatura a spirale in rame stagnato, tipo C:
schermatura a calza in rame stagnato copertura min85 %
shield elements: D: tinned spiral copper shield, resp. C: tinnedcopper braid, opt. coverage appr. 85 %
TPE - nero (se indicato 12Y) element sheath material TPE - black (if mentioned 12Y)elementi cordati insieme overall stranding elements stranded togethercalza in rame stagnato, copertura min 85% shield copper braids, tinned, opt. coverage appr. 85 %PVC outer sheath PVC
mat. guaina raggr. cond.cordatura totale
atura totalemateriale guaina esternacolore guaina verde - ral 6018 (DESINA), arancio - ral 2003 o nero -
ral 9005sheath colour GN - RAL 6018 (DESINA), OR - RAL 2003 or BK - RAL
9005
tensione nominale 300 V, non per potenza rated voltage 300 V, no high-voltage purposetensione di prova 500 V testing voltage 500 Vresistenza del conduttore secondo DIN VDE 0295 class 5 resp. IEC 60228 cl. 5 conductor resistance acc. to DIN VDE 0295 class 5 resp. IEC 60228 cl. 5resistenza d'isolamento min. 20 MΩ x km insulation resistance min. 20 MΩ x kmraggio min. curv. p. fissa 5 x d min. bending radius fixed 5 x draggio min. curv. p. mobile 15 x d min. bending radius moved 15 x dvelocità autoportante - max. 0,5 m/s speed self supporting - max. 0,5 m/slunghezza corsa max. 5 m traverse length max. 5 maccelerazione max. 2 m/s² acceleration max. 2 m/s²cicli di curvatura > 100.000 bending cycles > 100.000temp. eser. fissa min/max - 5 °C / +80 °C operat. temp. fixed min/max - 5 °C / +80 °Ctemp. eser. mobile min/max - 30 °C / +80 °C operat. temp. moved min/max - 30 °C / +80 °Ccomportamento al fuoco ritardante la fiamma secondo IEC 60332-1-2, FT1, VW-1 burning behavior flame-retardent acc. to IEC 60332-1-2, FT1, VW-1approvazioni UL/CSA: cURus 300V, 80°C approvals UL/CSA: cURus 300V, 80°C
.
art. n
Item no.
referenza OEM
OEM-Reference
n. conduttori & sezionen x mm²
dimensionn x mm²
diametromm
outer-Ømm
peso ramekg/km
Cu indexkg/km
peso nettokg/kmweightkg/km
colore guaina
sheath colour
1505189 6FX5008-1BD21 (4 X 2 X 0,34 +4X0,5)C 8,9 77,0 136,0 / green1505250 6FX5008-1BD31 (3 X (2 X 0,14)D12Y +2X(0,5)D12Y)C 8,5 69,0 115,0 / green1505190 6FX5008-1BD41 (3 X (2 X 0,14)D12Y +4X0,14 +2X0,5)C 8,9 66,0 125,0 / green1505191 6FX5008-1BD51 (3X(2X0,14)D12Y +4X0,14 +4X0,25 +2X0,5)C 9,4 86,0 147,0 / green
1505192 INK448 (4 X 2 X 0,25 + 2 X 0,5)C 8,4 61,0 113,0 orange1505193 INK209 (4 X 2 X 0,25 + 2 X 1)C 8,8 66,0 127,0 orange1505194 INK532 (4 X 1 + 4 X 2 X 0,14 + (4 X 0,14)D)C 9,7 90,0 155,0 orange
1505195 3 X (2 X 0,14)C + (2 X 0,5)C 9,3 49,0 135,0 / black1505196 4 X (2 X 0,14)C + (2 X 1)C 11,0 73,0 180,0 / black1505197 3 X (2 X 0,14)C + (3 X 0,14)C 9,2 43,0 120,0 / black
1505198 (5 X 2 X 0,25)C 7,3 47,0 91,0 / green1505199 (6 X 2 X 0,25)C 8,6 52,0 116,0 / green
.
cavo schermato a bassa capacità per collegamento di feedback, encoder, resolver, ta-chimetriche per connessioni in rispetto di EMC. Idoneo per uso in catene portacavi conrequisiti dinamici e meccanici elevati.
as shielded, low capacity feedback, encoder, resolver, spedo sensor, signal & sys-tem cables for EMC compatible connecting in and plant , as well as in drive and control technology, for high electrical and mechanical requirements in dragchain applications, moving drive systems and in the field of robotic technology.
• conforme a DESINA (guaina verde RAL 6018)• approvato cURus300V, 80°C• privo di alogeni e ritardante la fiamma secondo IEC 60332-1-2, FT1, VW-1• largamente resistente a grasso, liquidi refrigeranti e lubrificanti• resistente agli oli IEC 60811-404 (VDE 0473-811-404)• resistente agli UV• bassa aderenza, privo di silcone, ridotto in spazio e peso
• DESINA-conform (sheath colour green RAL 6018)• cURus Approbationen 300V, 80°C• halogen free and flame-retardant acc. to IEC 60332-1-2, FT1, VW-1• largely resistant to, grease, coolant fluids and lubricants• resistant to oil, IEC 60811-404 (VDE 0473-811-404)• UV-resistant• low adhesion, silicone-free, space- and weight-saving
• conforme a RoHS• conforme a 2006/95/EG guideline (CE marking)• ottimo rapporto qualità-prezzo• vita operativa allungata
• conform to RoHS• conform to 2006/95/EG guideline (CE marking)• optimal cost-value ratio• very long life time
materiale conduttore trefolo in rame rosso conductor material bare copper strandclasse conduttore sec. DIN VDE0295 cl. 6 resp. IEC 60228 cl. 6 conductor class acc. to DIN VDE0295 cl. 6 resp. IEC 60228 cl. 6isolamento conduttore PELON®2 core insulation PELON®2distinzione dei conduttori secondo le specifiche di sistema (su richiesta) core identification acc. to system specification (on request)cordatura conduttori cordati a coppie o strati stranding cores stranded to pairs or layersschermatura tipo: D: schermatura a spirale in rame stagnato, tipo C:
schermatura a calza in rame stagnato copertura min85 %
shield elements: C: copper braid tinned resp. D: spiral coppershield tinned, opt. coverage appr. 85%
TPE -nero (se indicato 12Y) element sheath material TPE - black (if mentioned 12Y)elementi cordati insieme overall stranding elements strand. togethercalza in rame stagnato,copertura min. 85% shield copper braid tinned, opt. coverage appr. 85%PUR outer sheath PUR
mat. guaina raggr. cond.cordatura totale
atura totalemateriale guaina esternacolore guaina verde - ral 6018 (DESINA), arancio - ral 2003 o nero -
ral 9005sheath colour GN - RAL 6018 (DESINA), OR - RAL 2003 or BK - RAL
9005
tensione nominale 300 V, non per potenza rated voltage 300 V, no high-voltage purposetensione di prova 500 V testing voltage 500 Vresistenza del conduttore secondo DIN VDE 0295 cl. 6 resp. IEC 60228 cl. 6 conductor resistance acc. to DIN VDE 0295 cl. 6 resp. IEC 60228 cl. 6resistenza d'isolamento min. 20 MΩ x km insulation resistance min. 20 MΩ x kmraggio min. curv. p. fissa 4 x d min. bending radius fixed 4 x draggio min. curv. p. mobile 7,5 x d < 10 m corsa | 10 x d ≥ 10 m corsa min. bending radius moved 7,5 x d < 10 m TL | 10 x d ≥ 10 m TLvelocità autoportante - max. 5 m/s speed self-supporting - max. 5 m/slunghezza corsa max. 50 m traverse length max. 50 maccelerazione max. 50 m/s² acceleration max. 50 m/s²cicli di curvatura > 5 Mio bending cycles > 5 Miotemp. eser. fissa min/max - 50 °C / +80 °C operat. temp. fixed min/max - 50 °C / +80 °Ctemp. eser. mobile min/max - 40 °C / +80 °C operat. temp. moved min/max - 40 °C / +80 °Cprivo di alogeni sì halogen free Yescomportamento al fuoco ritardante la fiamma sec. IEC 60332-1-2, FT1, VW-1 burning behavior flame-retardent acc. to IEC 60332-1-2, FT1, VW-1standard UL/CSA: cURus 300V, 80°C standard UL/CSA: cURus 300V, 80°C
.
art. n
Item no.
referenza OEM
OEM-Reference
n. conduttori & sezionen x mm²
dimensionn x mm²
diametromm
outer-Ømm
peso ramekg/km
Cu indexkg/km
peso nettokg/kmweightkg/km
colore guaina
sheath colour
1505200 6FX8008-1BD11 (8 X 2 X 0,18)C 7,8 54,0 85,0 / green1505201 6FX8008-1BD21 (4 X 2 X 0,34 +4X0,5)C 8,9 77,0 129,0 / green1505202 6FX8008-1BD31 (3 X (2 X 0,14)D12Y +2X(0,5)D12Y)C 9,0 69,0 120,0 / green1505203 6FX8008-1BD41 (3 X (2 X 0,14)D12Y +4X0,14 +2X0,5)C 8,9 66,0 120,0 / green1505204 6FX8008-1BD51 (3X(2X0,14)D12Y +4X0,14 +4X0,25 +2X0,5)C 9,6 86,0 135,0 / green1505205 6FX8008-1BD61 (4 X 2 X 0,18)C 6,4 35,0 61,0 / green1505206 6FX8008-1BD71 (2 X 2 X 0,18)C 5,0 24,0 39,0 / green1505207 6FX8008-1BD81 (12 X 0,22)C 6,9 49,0 77,0 / green
1505208 INK448 grün (4 X 2 X 0,25 + 2 X 0,5)C 8,5 61,0 105,0 / green1505209 INK209 grün (4 X 2 X 0,25 + 2 X 1)C 8,8 66,0 119,0 / green1505210 INK208 grün (9 X 0,5)C 8,8 69,0 127,0 / green1505211 INK448 (4 X 2 X 0,25 + 2 X 0,5)C 8,5 52,0 105,0 orange1505212 INK209 (4 X 2 X 0,25 + 2 X 1)C 8,8 66,0 119,0 orange1505213 INK208 (9 X 0,5)C 8,8 69,0 127,0 orange1505214 INK532 (4 X 1 + 4 X 2 X 0,14 + (4 X 0,14)D)C 9,5 90,0 145,0 orange1505215 INK280 (3 X (2 X 0,25)D + 3 X 0,25 + 2 X 1)C 9,0 95,0 151,0 orange1505216 INK750 (2 X 2 X 0,25 + 2 X 0,5)C 7,2 52,0 151,0 orange
1505217 3 X (2 X 0,14)C + (2 X 0,5)C 9,9 54,0 124,0 / green1505218 4 X (2 X 0,14)C + (2 X 1)C 11,0 73,0 168,0 / green1505219 3 X (2 X 0,14)C + (3 X 0,14)C 9,2 43,0 120,0 / green
1505220 (3 X 2 X AWG24)C 6,5 31,0 57,0 / green1505221 (5 X 2 X 0,14 + 2 X 0,5)C 7,8 48,0 79,0 / green
1505222 (3 X (2 X 0,14)D12Y + 2 X (1 X 0,5)D12Y)C 8,4 75,0 103,0 / black1505223 (4 X 2 X 0,14 + 4 X 0,5)C 8,5 52,0 103,0 / black1505224 (3 X (2 X 0,14)D12Y + 2 X (1 X 1)D12Y)C 9,1 81,0 132,0 / black1505225 (4 X 2 X 0,14 + (4 X 0,14)D + 4 X 0,5)C 9,0 81,0 123,0 / black1505249 (10 X 0,14 + 2 X 0,5)C 7,2 43,0 79,0 / black
1505226 (5 X 2 X 0,25)C 7,6 47,0 82,0 / green1505227 (6 X 2 X 0,25)C 7,9 52,0 108,0 / green
1505228 (3 X (2 X 0,25)D)C 7,2 58,0 80,0 / green1505229 (4 X (2 X 0,25)C + 2 X 0,5)C 10,2 116,0 162,0 / green1505230 (4 X (2 X 0,25)C + 2 X 1)C 10,5 133,0 185,0 / green1505248 (4 X 2 X 0,14 + 4 X 0,25)C 6,1 41,0 70,0 / black
.
cavo per trasmissione di segnali digitali di misura in azionamenti SINAMICS, DRIVE-CLiQ® è un'interfaccia encoder aperta con un trasferimento fino a 100Mbit/s. Adattoall'uso in ambienti asciutti e umidi. Usare in ambienti esterni solo con protezione UV
For transmitting digital signals for various drive components to DRIVE-CLiQ® interfa-ces, with a transfer rate up to 100Mbit/s. Suitable for use in dry and humid rooms. Out-door use only with
• ritardante la fiamma• resistente agli oli secondo IEC 60811-2-1• privo di silicone (in fase di produzione)• HF-caratteristiche Cat.5e secondo IEC 61156-6• l'appendice- KAWEFLEX® ServoDriveQ ... parametri di applicazione -• grazie a 300V UL/CSA la posa in parallelo con altri cavi 300V è consentita• NEW: dalla data di produzione Gen. 2016, approvazione UL/CSA, 300 V, 80 °C (pre-
cedente: 30 V, 80 °C)
• flame retardant• oil resistant acc. to IEC 60811-2-1• free from lacquer damaging substances and silicone (during production)• HF-characteristics Cat.5e acc. to IEC 61156-6• see appendix - KAWEFLEX® ServoDriveQ ... application parameters -• due to 300V UL/CSA approval parallel laying with other 300V cables is permitted• NEW: up from production date Jan. 2016, approbation UL/CSA, 300 V, 80 °C (OLD: 30
V, 80 °C)
• confome a RoHS e WEEE• disponibile anche c(UL)us Listing Type CMG secondo UL444• ulteriori tipologie su richiesta• DRIVE-CLiQ®è un marchio registrato di Siemens AG
• confom to RoHS and WEEE• alternatively as c(UL)us Listing Type CMG acc. UL444 available• further types upon request• DRIVE-CLiQ® is registered Trademark of Siemens AG
trefolo in rame rosso conductor material bare copper7 fili conductor class 7-wiresPE espanso core insulation foam Polyethylenverde/giallo , rosa/blu core identification GN/YE, PK/BUconduttori e riempitivo twistati a coppie stranding cores and fillers twisted to pairs2 coppie cordate con riempitivo overall stranding 2 pairs stranded with fillersnastro plastico protection against contact plastic-fleece/-foil tape
materiale conduttoreclasse conduttoreisolamento conduttoredistinzione dei conduttoricordaturacordatura totaleprotezione da contatto
atura totale foglio di PET rivestito di alluminio in contatto con calza,copertura 100%, calza in rame stagnato con coperturamin 85%
shield alu-clad PET foil, metalside with contact to braid, co-ver.100%,tinned copper braid, opt.cover. ≥85%
protezione da contatto nastro separatore protection against contact seperating layermateriale guaina esterna PVC outer sheath PVCcolore guaina grigio RAL 7032 sheath colour grey, RAL 7032
tensione nominale max. 300 V rated voltage max. 300 Vtensione di prova 500 V testing voltage 500 Vresistenza del conduttore AWG24 max. 87,6 Ω/km conductor resistance AWG24 max. 87,6 Ω/kmresistenza d'isolamento at 20 °C ≥ 1 GΩ/km insulation resistance at 20 °C ≥ 1 GΩ/kmcapacità nom. 50 nF/km a 800 Hz capacity nom. 50 nF/km at 800 Hzimpedenza caratteristica 100 ± 15 Ω da 1 a 100 MHz characteristic impedance 100 ± 15 Ω from 1 to 100 MHzvelocitá trasmissione dati 100 Mbit/s transfer rate 100 Mbit/sraggio min. curv. p. fissa 7,5 x d min. bending radius fixed 7,5 x draggio min. curv. p. mobile 15 x d min. bending radius moved 15 x dtemp. eser. fissa min/max - 20 °C / +80 °C operat. temp. fixed min/max - 20 °C / +80 °Ccomportamento al fuoco secondo IEC 60332-1-2, UL - VW1; CSA -FT1 burning behavior acc. to IEC60332-1-2, UL VW-1 resp. CSA FT1approvazioni UL/CSA - cURus 300 V, 80°C approvals UL/CSA - cURus 300 V, 80°C, up from production date
Jan. 2016diametro esterno ca. 6,85 mm outer diameter ca. 6,85 mmcontenuto rame 28,0 kg/km Cu index 28,0 kg/kmpeso ca. 60,0 kg/km weight ca. 60,0 kg/kmcodice TKD 2001494 TKD Item no. 2001494
.
cavo per trasmissione di segnali digitali di misura in azionamenti SINAMICS, DRIVE-CLiQ® è un'interfaccia encoder aperta con un trasferimento fino a 100Mbit/s. Adattoall'uso in ambienti asciutti e umidi. Usare in ambienti esterni solo con protezione UV
For flexible use in applications with high electrical requirements for controlling of variousdrive components on DRIVE-CLiQ® interfaces and digital signals, with a transfer rate ofup to 100Mbit/s. Suitable for use in dry and humid rooms. Outdoor use only with
• ritardante la fiamma• resistente agli oli secondo IEC 60811-2-1• privo di silicone• conforme a DESINA• HF caratteristiche Cat.5e secondo IEC 61156-6• grazie a 300V UL/CSA la posa in parallelo con altri cavi 300V è consentita• NEW: dalla data di produzione Gen. 2016, approvazione UL/CSA, 300 V, 80 °C (pre-
cedente: 30 V, 80 °C)
• flame retardant• oil resistant acc. to IEC 60811-2-1• free from lacquer damaging substances and silicone (during production)• conform to DESINA• HF-characteristics Cat.5e acc. to IEC 61156-6• due to 300V UL/CSA approval parallel laying with other 300V cables is permitted• NEW: up from production date Jan. 2016, approbation UL/CSA, 300 V, 80 °C (OLD: 30
V, 80 °C)
• conforme a RoHS e WEEE• disponibile anche c(UL)us Listing Type CMG secondo UL444• ulteriori tipologie su richiesta• parametri di applicazione s. app. - KAWEFLEX® ServoDriveQ...parametri di applica-
zione -
• confom to RoHS and WEEE• alternatively as c(UL)us Listing Type CMG acc. UL444 available• further types upon request• application parameters s. app. - KAWEFLEX® ServoDriveQ...application parameters -• DRIVE-CLiQ® is registered Trademark of Siemens AG
materiale conduttore trefolo in rame rosso (AWG24), rame stagnato (AWG22) conductor material bare copper (AWG24), tinned copper (AWG22)classe conduttore 7-fili (AWG24), 19-fili (AWG22) conductor class 7-wires (AWG24), 19-wires (AWG22)isolamento conduttore PE espanso (AWG24), poliolefina (AWG22) core insulation foam Polyethylen (AWG24), Polyolefin (AWG22)distinzione dei conduttori coppie AWG24 giallo/verde , rosa/blu coppia AWG22 ro-
so/nerocore identification pairs AWG24 GN/YE, PK/BU pair AWG22 RD/BK
conduttori e riempitivo twistati in coppie stranding cores and fillers twisted to pairs3 elementi cordati con riempitivo overall stranding 3 elements stranded with fillersnastro di tessuto protection against contact fleece tape
cordaturacordatura totaleprotezione da contatto
atura totale foglio PET metallizzato a contatto con calza cop.100%calza in rame stagnato con copertura min. 85%
shield alu-clad PET foil, metalside with contact to braid co-ver.100%, tinned copper braid, opt.cover.≥85%
protezione da contatto tessuto non tessuto protection against contact fleece wrappingmateriale guaina esterna PVC outer sheath PVCcolore guaina verde RAL 6018 sheath colour green, RAL 6018
tensione nominale max. 300 V rated voltage max. 300 Vtensione di prova 500 V testing voltage 500 Vresistenza del conduttore AWG24 max. 90 Ω/km , AWG22 max. 55 Ω/km conductor resistance AWG24 max. 90 Ω/km , AWG22 max. 55 Ω/kmresistenza d'isolamento a 20 °C ≥ 1 GΩ/km insulation resistance at 20 °C ≥ 1 GΩ/kmcapacità coppia dati: nom. 50 nF/km a 800 Hz capacity data pairs: nom. 50 nF/km at 800 Hzimpedenza caratteristica 100 ± 15 Ω da 1 a 100 MHz characteristic impedance 100 ± 15 Ω from 1 to 100 MHzvelocitá trasmissione dati 100 Mbit/s transfer rate 100 Mbit/sraggio min. curv. p. fissa 35,0 mm min. bending radius fixed 35,0 mmraggio min. curv. p. mobile 125,0 mm min. bending radius moved 125,0 mmtemp. eser. fissa min/max - 20 °C / +80 °C operat. temp. fixed min/max - 20 °C / +80 °Ctemp. eser. mobile min/max - 0 °C / +60 °C operat. temp. moved min/max - 0 °C / +60 °Ccomportamento al fuoco secondo IEC 60332-1-2, UL - VW1; CSA- FT1 burning behavior acc. to IEC60332-1-2, UL VW-1 resp. CSA FT1approvazioni UL/CSA - cURus 300 V, 80°C approvals UL/CSA - cURus 300 V, 80°C, up from production date
Jan. 2016diametro esterno ca. 6,95 mm outer diameter ca. 6,95 mmcontenuto rame 41,0 kg/km Cu index 41,0 kg/kmpeso ca. 68 kg/km weight ca. 68,0 kg/kmcodice TKD 2001499 TKD Item no. 2001499
.
cavo per trasmissione di segnali digitali e applicazioni in catena portacavi con requisitidinamici e meccanici elevati di misura in azionamenti SINAMICS, DRIVE-CLiQ® èun'interfaccia encoder aperta con un trasferimento fino a 100Mbit/s. Adatto all'uso inambienti asciutti e umidi. Usare in ambienti esterni solo con protezione UV
For use in dynamic applications in energy supply chains, with high electrical and me-chanical requirements for controlling of various drive components on DRIVE-CLiQ ® in-terfaces and transmitting digital signals, with a transfer rate up to 100Mbit/s. Suitable foruse in dry and humid rooms. Outdoor use only with UV-protection.
• privo di alogeni, ritardante la fiamma• resistente agli oli secondo IEC 60811-2-1• privo di silicone• conforme a DESINA• HF caratteristiche Cat.5e secondo IEC 61156-6• grazie a 300V UL/CSA la posa in parallelo di altri cavi 300V è consentita• NEW: dalla data di produzione Gen. 2016, approvazione UL/CSA, 300 V, 80 °C (pre-
cedente: 30 V, 80 °C)
• halogen-free, flame retardant• oil resistant acc. to IEC 60811-2-1• free from lacquer damaging substances and silicone (during production)• conform to DESINA• HF-characteristics Cat.5e acc. to IEC 61156-6• due to 300V UL/CSA approval parallel laying with other 300V cables is permitted• NEW: up from production date Jan. 2016, approbation UL/CSA, 300 V, 80 °C (OLD: 30
V, 80 °C)
• confome a RoHS e WEEE• disponibile anche c(UL)us Listing Type CMG secondo UL444• ulteriori tipologie su richiesta• parametri di applicazione s. app. - KAWEFLEX® ServoDriveQ... parametri di applica-
zione -
• confom to RoHS and WEEE• alternatively as c(UL)us Listing Type CMX acc. UL444 available• further types upon request• application parameters s. app. - KAWEFLEX® ServoDriveQ... application parameters -• DRIVE-CLiQ® is registered Trademark of Siemens AG
materiale conduttore trefolo in rame rosso (AWG26), rame stagnato (AWG22) conductor material bare copper (AWG26), tinned copper (AWG22)classe conduttore 19 fili conductor class 19-wiresisolamento conduttore poliolefina core insulation Polyolefindistinzione dei conduttori coppie AWG26 verde/giallo , rosa/blu coppia AWG22
rosso/nerocore identification pairs AWG26 YE/GN, PK/BU pair AWG22 RD/BK
conduttori e riempitivo twistati a coppie stranding cores and fillers twisted to pairs3 elementi cordati con riempitivo overall stranding 3 elements stranded with fillerstessuto non tessuto protection against contact fleece tape
cordaturacordatura totaleprotezione da contatto
atura totale foglio metal. di PET a contatto con calza cop.100%calza in rame stagnato con copertura min 85%
shield alu-clad PET foil, metalside with contact to braid co-ver.100%, tinned copper braid, opt.cover. ≥85%
protezione da contatto tessuto non tessuto protection against contact fleece wrappingmateriale guaina esterna PUR outer sheath PURcolore guaina verde RAL 6018 sheath colour green, RAL 6018
tensione nominale max. 300 V rated voltage max. 300 Vtensione di prova 500 V testing voltage 500 Vresistenza del conduttore AWG26 max. 135 Ω/km , AWG22 max. 55 Ω/km conductor resistance AWG26 max. 135 Ω/km , AWG22 max. 55 Ω/kmresistenza d'isolamento a 20 °C ≥ 1 GΩ/km insulation resistance at 20 °C ≥ 1 GΩ/kmcapacità coppia dati: nom. 50 nF/km a 800 Hz capacity data pairs: nom. 50 nF/km at 800 Hzimpedenza caratteristica 100 ± 15 Ω da 1 a 100 MHz characteristic impedance 100 ± 15 Ω from 1 to 100 MHzvelocitá trasmissione dati 100 Mbit/s transfer rate 100 Mbit/sraggio min. curv. p. fissa 35,0 mm min. bending radius fixed 35,0 mmraggio min. curv. p. mobile 105,0 mm min. bending radius moved 105,0 mmtemp. eser. fissa min/max - 20 °C / +80 °C operat. temp. fixed min/max - 20 °C / +80 °Ctemp. eser. mobile min/max - 20 °C / +60 °C operat. temp. moved min/max - 20 °C / +60 °Ccomportamento al fuoco secondo IEC 60332-1-2, UL - VW1; CSA -FT1 burning behavior acc. to IEC60332-1-2 resp. UL VW1 + CSA FT1approvazioni UL/CSA - cURus 300 V, 80°C approvals UL/CSA - cURus 300 V, 80°C, up from prod. date Jan.
2016diametro esterno ca. 6,95 mm outer diameter ca. 6,95 mmcontenuto rame 37,5 kg/km Cu index 37,5 kg/kmpeso ca. 65 kg/km weight ca. 65,0 kg/kmcodice TKD 2007185 TKD Item no. 2007185
.
cavo per trasmissione di segnali digitali e applicazioni in catena portacavi con requisitidinamici e meccanici elevati di misura in azionamenti SINAMICS, DRIVE-CLiQ® èun'interfaccia encoder aperta con un trasferimento fino a 100Mbit/s. Adatto all'uso inambienti asciutti e umidi. Usare in ambienti esterni solo con protezione UV
For use in highly dynamic applications in energy supply chains, with high electrical andmechanical requirements for controlling of various drive components on DRIVE-CLiQ ®interfaces and transmitting digital signals, with a transfer rate up to 100Mbit/s. Suitablefor use in dry and humid rooms. Outdoor use only with UV-protection.
• privo di alogeni, ritardante la fiamma• resistente agli oli secondo IEC 60811-2-1• privo di silicone• approvazione UL/CSA, 300V, 80°C• grazie all'approvazione UL/CSA 300V, la posa in parallelo con altri cavi da 300V è per-
messa• conforme DESINA• HF caratteristiche Cat.5e secondo IEC 61156-6
• halogen-free, flame retardant• oil resistant acc. to IEC 60811-2-1• free from lacquer damaging substances and silicone (during production)• approbation UL/CSA, 300V, 80°C• due to 300V UL/CSA approval parallel laying with other 300V cables is permitted• conform to DESINA• HF-characteristics Cat.5e acc. to IEC 61156-6
• conforme a RoHS e WEEE• in alternativa come c(UL)us Listing Type CMX acc. UL444 disponibile• ulteriori tipologie su richiesta• parametri di applicazione s. app. - KAWEFLEX® ServoDriveQ...parametri di applica-
zione -
• confom to RoHS and WEEE• alternatively as c(UL)us Listing Type CMX acc. UL444 available• further types upon request• application parameters s. app. - KAWEFLEX® ServoDriveQ...application parameters -• DRIVE-CLiQ® is registered Trademark of Siemens AG
materiale conduttore trefolo in rame rosso (AWG24), rame stagnato (AWG22) conductor material bare copper (AWG24), tinned copper (AWG22)classe conduttore 19 fili conductor class 19-wiresisolamento conduttore poliolefina core insulation Polyolefindistinzione dei conduttori coppie AWG24 verde/giallo , rosa/blu coppia AWG22
rosso/nerocore identification pairs AWG24 GN/YE, PK/BU pair AWG22 RD/BK
conduttori e rimpitivo twistati a coppie stranding cores and fillers twisted to pairs3 elementi cordati con riempitivo overall stranding 3 elements stranded with fillerstessuto non tessuto protection against contact fleece tape
cordaturacordatura totaleprotezione da contatto
atura totale foglio di PET metallizzato a contatto con calza cop.100%calza in rame stagnato con copertura min. 85%
shield alu-clad PET foil, metalside with contact to braid co-ver.100%, tinned copper braid, opt.cover. ≥85%
protezione da contatto tessuto non tessuto protection against contact fleece wrappingmateriale guaina esterna PUR outer sheath PURcolore guaina verde RAL 6018 sheath colour green, RAL 6018
tensione nominale 300 V rated voltage 300 Vtensione di prova 500 V testing voltage 500 Vresistenza del conduttore AWG24 max. 95 Ω/km , AWG22 max. 55 Ω/km conductor resistance AWG24 max. 95 Ω/km , AWG22 max. 55 Ω/kmresistenza d'isolamento at 20 °C ≥ 1 GΩ/km insulation resistance at 20 °C ≥ 1 GΩ/kmcapacità coppie dati: nom. 50 nF/km at 800 Hz capacity data pairs: nom. 50 nF/km at 800 Hzimpedenza caratteristica 100 ± 15 Ω da 1 a 100 MHz characteristic impedance 100 ± 15 Ω from 1 to 100 MHzvelocitá trasmissione dati 100 Mbit/s transfer rate 100 Mbit/sraggio min. curv. p. fissa 35,0 mm min. bending radius fixed 35,0 mmraggio min. curv. p. mobile 75,0 mm min. bending radius moved 75,0 mmtemp. eser. fissa min/max - 40 °C / +80 °C operat. temp. fixed min/max - 40 °C / +80 °Ctemp. eser. mobile min/max - 20 °C / +60 °C operat. temp. moved min/max - 20 °C / +60 °Ccomportamento al fuoco secondo IEC 60332-1-2, UL - VW1; CSA -FT1 burning behavior acc. to IEC60332-1-2, UL VW-1 resp. CSA FT1approvazioni UL/CSA - cURus 300 V, 80°C approvals UL/CSA - cURus 300 V, 80°Cdiametro esterno ca. 6,9 mm outer diameter ca. 6,9 mmcontenuto rame 40,0 kg/km Cu indexcodice TKD 2001439 TKD Item no. 2001493
.
cavi unipolari di potenza flessibili per uso in catene portacavi con requisiti meccanici, di-namici ed elettrici estremi, idoneo per impiego in linee automatiche, impianti di produ-zione, sistemi di sollevamento e trasporto in ambienti asciutti, umidi e in esterni.
flexible single core power cable for highest electrical and mechanical requirements indrag chain and motion drive systems in machine and plant in the field ofcrane and conveyor technology in dry and humid rooms also outdoor.
• conforme a DESINA• approvato UL/CSA• privo di alogeni, ritardante la fiamma, bassa abrasione, resistente a idrolisi e microbi• resistente all'azione di grassi, lubrificanti, liquidi refrigeranti• resistente agli oli secondo DIN EN 60811-2-1• privo di silicone• resistente ai raggi UV
• conform to DESINA• UL/CSA approved• flame-retardant, low abrasion, resistant to hydrolysis and microbe• resistant to grease, coolant fluids and lubricants• resistant to oil acc. to DIN EN 60811-2-1• silicone-free• UV-resistant
• conforme a RoHS• conforme a 2006/95/EC-Guideline (CE direttiva bassa tensione)
• conform to RoHS• conform to 2006/95/EC-Guideline (CE marking)
materiale conduttore rame rosso a fasci conductor material bare copper bundle strandclasse conduttore fili sottili secondo DIN VDE 0295 cl. 6, IEC 60228 cl.6 conductor class super fine wires acc. to DIN VDE 0295 cl. 6 resp. IEC
60228 cl. 6isolamento conduttore TPE core insulation TPEdistinzione dei conduttori naturale core identification naturemateriale guaina esterna TPE outer sheath TPEcolore guaina nero ( RAL 9005) sheath colour black (RAL 9005)marcatura secondo standard TKD printing acc. to TKD printnorm
tensione nominale 600/1.000 V rated voltage 600/1.000 Vtensione di prova 4.000 V testing voltage 4.000 Valtre caratteristiche max. accelerazione 100 m/s²; velocità con catena auto-
portante 10 m/s; scorrevole fino a 6 m/s; max. lunghez-za catena autoportante/scorrevole 400 m
other characteristics max. acceleration 100 m/s²; speed self-supporting up to10 m/s, gliding up to 6 m/s; max. path length self-sup-porting/gliding to 400 m
raggio min. curv. p. fissa 4 x d min. bending radius fixed 4 x draggio min. curv. p. mobile 7,5 x d min. bending radius moved 7,5 x dtemp. eser. fissa min/max -40 °C / +90 °C operat. temp. fixed min/max -40 °C / +90 °Ctemp. eser. mobile min/max -35 °C / +90 °C operat. temp. moved min/max -35 °C / +90 °Ccomportamento al fuoco secondo IEC 60332-1, test della fiamma, FT1 burning behavior acc. to IEC 60332-1, cable flame test, FT1approvazioni UL 80 °C, 1.000 V, cULus 80 °C, 1.000 V approvals UL 80 °C, 1.000 V, cULus 80 °C, 1.000 V
.
art. n
Item no.
n. conduttori &sezione
dimensionn x mm²
diametromm
outer-Ømm
peso ramekg/km
Cu indexkg/km
peso nettokg/kmweightkg/km
1706200 1 X 1,5 4,8 15,0 33,01706201 1 X 2,5 5,5 25,0 47,01706202 1 X 4 6,1 40,0 64,01706203 1 X 6 7,0 60,0 96,01706204 1 X 10 8,0 100,0 142,01706205 1 X 16 9,5 160,0 211,01706206 1 X 25 11,5 250,0 323,0
.
art. n
Item no.
n. conduttori &sezione
dimensionn x mm²
diametromm
outer-Ømm
peso ramekg/km
Cu indexkg/km
peso nettokg/kmweightkg/km
1706207 1 X 35 12,5 350,0 428,01706208 1 X 50 14,5 500,0 598,01706209 1 X 70 16,5 700,0 801,01706211 1 X 120 21,5 1.200,0 1.280,01706210 1 X 95 19,0 950,0 1.061,01706212 1 X 150 23,0 1.500,0 1.605,01706213 1 X 185 27,0 1.850,0 1.996,0
cavi unipolari di potenza flessibili per uso in catene portacavi con requisiti meccanici, di-namici ed elettrici estremi, idoneo per impiego in linee automatiche, impianti di produ-zione, sistemi di sollevamento e trasporto in ambienti asciutti, umidi e esterni.
flexible single core power cable for highest electrical and mechanical requirements indrag chain and motion drive systems in machine and plant in the field ofcrane and conveyor technology in dry and humid rooms also outdoor.
• approvato UL/CSA• privo di alogeni, ritardante la fiamma, bassa adesione,resistente all'idrolisi e ai microbi• resistente all'azione di grassi, lubrificanti, liquidi refrigeranti• resistente agli oli secondo DIN EN 60811-2-1• privo di silicone• resistente ai raggi UV
• UL/CSA approved• flame-retardant, low abrasion, resistant to hydrolysis and microbe• resistant to grease, coolant fluids and lubricants• resistant to oil acc. to DIN EN 60811-2-1• silicone-free• UV-resistant
• conforme a RoHS• conforme a 2006/95/EC-Guideline (CE marking)
• conform to RoHS• conform to 2006/95/EC-Guideline (CE marking)
materiale conduttore rame rosso a fasci conductor material bare copper bundle strandclasse conduttore fili sottili conforme a DIN VDE 0295 cl.6 , IEC 60228 cl.6 conductor class super fine wires acc. to DIN VDE 0295 cl. 6 resp. IEC
60228 cl. 6isolamento conduttore TPE core insulation TPEdistinzione dei conduttori G/V core identification GNYEmateriale guaina esterna TPE outer sheath TPEcolore guaina nero ( RAL 9005) sheath colour black (RAL 9005)marcatura secondo standard TKD printing acc. to TKD printnorm
tensione nominale 600/1.000 V rated voltage 600/1.000 Vtensione di prova 4.000 V testing voltage 4.000 Valtre caratteristiche max. accelerazione 100 m/s²; velocità con catena auto-
portante 10 m/s; scorrevole fino a 6 m/s; max. lunghez-za catena autoportante/scorrevole 400 m
other characteristics max. acceleration 100 m/s²; speed self-supporting up to10 m/s, gliding up to 6 m/s; max. path length self-sup-porting/gliding to 400 m
raggio min. curv. p. fissa 4 x d min. bending radius fixed 4 x draggio min. curv. p. mobile 7,5 x d min. bending radius moved 7,5 x dtemp. eser. fissa min/max -40 °C / +90 °C operat. temp. fixed min/max -40 °C / +90 °Ctemp. eser. mobile min/max -35 °C / +90 °C operat. temp. moved min/max -35 °C / +90 °Ccomportamento al fuoco secondo IEC 60332-1, test della fiamma, FT1 burning behavior acc. to IEC 60332-1, cable flame test, FT1approvazioni UL 80 °C, 1.000 V, cULus 80 °C, 1.000 V approvals UL 80 °C, 1.000 V, cULus 80 °C, 1.000 V
.
art. n
Item no.
n. conduttori &sezione
dimensionn x mm²
diametromm
outer-Ømm
peso ramekg/km
Cu indexkg/km
peso nettokg/kmweightkg/km
1706400 1 G 1,5 4,8 15,0 33,01706401 1 G 2,5 5,5 25,0 47,01706402 1 G 4 6,1 40,0 64,01706403 1 G 6 7,0 60,0 96,01706404 1 G 10 8,0 100,0 142,01706405 1 G 16 9,5 160,0 211,01706406 1 G 25 11,5 250,0 323,0
.
art. n
Item no.
n. conduttori &sezione
dimensionn x mm²
diametromm
outer-Ømm
peso ramekg/km
Cu indexkg/km
peso nettokg/kmweightkg/km
1706407 1 G 35 12,5 350,0 428,01706409 1 G 50 14,5 500,0 598,01706411 1 G 70 16,5 700,0 801,01706413 1 G 95 19,0 950,0 1.061,01706415 1 G 120 21,5 1.200,0 1.280,01706417 1 G 150 23,0 1.500,0 1.605,01706419 1 G 185 27,0 1.850,0 1.996,0
cavi schermati unipolari di potenza per applicazioni EMC flessibili per uso in catene por-tacavi con requisiti meccanici, dinamici ed elettrici estremi, idoneo per impiego in lineeautomatiche, impianti di produzione, sistemi di sollevamento e trasporto in ambienti as-ciutti, umidi e anche esterni.
flexible shielded single core power cable for EMC-compatible at highestelectrical and mechanical requirements in drag chain and motion drive systems in ma-chine and plant in the field of crane and conveyor technology in dry and humid rooms also outdoor.
• approvato UL/CSA• privo di alogeni, ritardante la fiamma, bassa abrasione, resistente all'idrolisi e ai micro-
bi• resistente all'azione di grassi, lubrificanti, liquidi refrigeranti• resistente agli oli secondo DIN EN 60811-2-1• privo di silicone• resistente ai raggi UV
• UL/CSA approved• flame-retardant, low abrasion, resistant to hydrolysis and microbe• resistant to grease, coolant fluids and lubricants• resistant to oil acc. to DIN EN 60811-2-1• silicone-free• UV-resistant
• conforme a RoHS• conform a2006/95/EC-Guideline (CE marking)
• conform to RoHS• conform to 2006/95/EC-Guideline (CE marking)
materiale conduttore rame rosso a fasci conductor material bare copper bundle strandclasse conduttore fili sottili conforme a DIN VDE 0295 cl.6 , IEC 60228 cl.6 conductor class super fine wires acc. to DIN VDE 0295 cl. 6 resp. IEC
60228 cl. 6TPE core insulation TPEnaturale core identification naturecalza in rame stagnato con copertura min.85% shield copper braid tinned, opt. coverage appr. 85 %TPE outer sheath TPEnero ( RAL 9005) sheath colour black (RAL 9005)
isolamento conduttoredistinzione dei conduttori
materiale guaina esternacolore guainamarcatura secondo standard TKD printing acc. to TKD printnorm
tensione nominale 600/1.000 V rated voltage 600/1.000 Vtensione di prova 4.000 V testing voltage 4.000 Valtre caratteristiche max. accelerazione 100 m/s²; velocità con catena auto-
portante 10 m/s; scorrevole fino a 6 m/s; max. lunghez-za catena autoportante/scorrevole 400 m
other characteristics max. acceleration 100 m/s²; speed self-supporting up to10 m/s, gliding up to 6 m/s; max. path length self-sup-porting/gliding to 400 m
raggio min. curv. p. fissa 4 x d min. bending radius fixed 4 x draggio min. curv. p. mobile 7,5 x d min. bending radius moved 7,5 x dtemp. eser. fissa min/max -40 °C / +90 °C operat. temp. fixed min/max -40 °C / +90 °Ctemp. eser. mobile min/max -35 °C / +90 °C operat. temp. moved min/max -35 °C / +90 °Ccomportamento al fuoco secondo IEC 60332-1, test della fiamma, FT1 burning behavior acc. to IEC 60332-1, cable flame test, FT1approvazioni UL 80 °C, 1.000 V, cULus 80 °C, 1.000 V approvals UL 80 °C, 1.000 V, cULus 80 °C, 1.000 V
.
art. n
Item no.
n. conduttori &sezione
dimensionn x mm²
diametromm
outer-Ømm
peso ramekg/km
Cu indexkg/km
peso nettokg/kmweightkg/km
1706600 1 X 1,5 5,4 25,0 43,01706601 1 X 2,5 6,1 37,0 58,01706602 1 X 4 6,7 54,0 78,01706603 1 X 6 7,5 75,0 114,01706604 1 X 10 8,4 116,0 160,01706605 1 X 16 10,1 179,0 238,01706606 1 X 25 12,0 272,0 348,0
.
art. n
Item no.
n. conduttori &sezione
dimensionn x mm²
diametromm
outer-Ømm
peso ramekg/km
Cu indexkg/km
peso nettokg/kmweightkg/km
1706607 1 X 35 13,6 390,0 483,01706608 1 X 50 15,0 541,0 639,01706609 1 X 70 17,5 744,0 880,01706610 1 X 95 20,5 1.028,0 1.109,01706611 1 X 120 22,6 1.277,0 1.410,01706612 1 X 150 24,0 1.572,0 1.736,01706613 1 X 185 28,0 1.937,0 2.071,0
cavi di collegamento motore flessibili per uso in catene portacavi con requisiti meccani-ci, dinamici ed elettrici elevati, idoneo per impiego in linee automatiche, impianti di pro-duzione, sistemi di sollevamento e trasporto. Idonei per uso in ambienti secchi,umidi eall'aperto.
flexible power cable for high electrical and mechanical requirements in drag chain andmotion drive systems in machine and plant engineering in the field of crane and con-veyor technology in dry and humid rooms also outdoor.
• approvato UL/CSA• ritardante la fiamma• resistente agli oli secondo DIN EN 50363-4-1, cl2• privo di silicone• resistente ai raggi UV
• UL/CSA approved• flame-retardant• resistant to oil acc. to DIN EN 50363-4-1, cl. 2• silicone-free• UV-resistant
• conforme a RoHS• conforme alla 2006/95/EC-("Direttiva Bassa Tensione") CE
• conform to RoHS• conform to 2006/95/EC-Guideline (CE marking)
materiale conduttore trefolo in rame rosso conductor material bare copper strandclasse conduttore fili sottili conforme a DIN VDE 0295 cl.6 , IEC 60228 cl.6 conductor class super fine wires acc. to DIN VDE 0295 cl. 6 resp. IEC
60228 cl. 6isolamento conduttore TPE core insulation TPEdistinzione dei conduttori neri con numerazione bianca, 1x G/V 1.cond.: U / L1 / C
/ L+ *** 2.cond.: V / L2 3.cond.: W / L3 / D / L- *** 4.cond.: 4 / N
core identification BK with WH numerals, one core GNYE 1.core: U / L1 /C / L+ *** 2.core: V / L2 3.core: W / L3 / D / L- *** 4.core:4 / N
cordatura conduttori cordati attorno a elemento di rinforzo centrale stranding cores stranded in opt. lay length around tensile strengthcenter
materiale guaina esterna PVC, bassa aderenza outer sheath PVC, low adhesioncolore guaina nero ( RAL 9005) sheath colour black (RAL 9005)marcatura secondo standard TKD printing acc. to TKD printnorm
tensione nominale 600/1.000 V rated voltage 600/1.000 Vtensione di prova 4.000 V testing voltage 4.000 Valtre caratteristiche max. accelerazione 80 m/s²; velocità con catena auto-
portante 10 m/s; scorrevole fino a 5 m/s; max. lunghez-za catena autoportante/scorrevole 100 m
other characteristics max. acceleration 80 m/s²; speed self-supporting up to10 m/s, gliding up to 5 m/s; max. path length self-sup-porting/gliding to 100 m
raggio min. curv. p. fissa 4 x d min. bending radius fixed 4 x draggio min. curv. p. mobile 7,5 x d min. bending radius moved 7,5 x dtemp. eser. fissa min/max -20 °C / +70 °C operat. temp. fixed min/max -20 °C / +70 °Ctemp. eser. mobile min/max -5 °C / +70 °C operat. temp. moved min/max -5 °C / +70 °Ccomportamento al fuoco secondo IEC 60332-1, test della fiamma, FT1 burning behavior acc. to IEC 60332-1, cable flame test, FT1approvazioni UL 80 °C, 1.000 V, cULus 80 °C, 1.000 V approvals UL 80 °C, 1.000 V, cULus 80 °C, 1.000 V
.
art. n
Item no.
n. conduttori &sezione
dimensionn x mm²
diametromm
outer-Ømm
peso ramekg/km
Cu indexkg/km
peso nettokg/kmweightkg/km
1705000 4 G 1,5 7,6 58,0 100,0
1705001 4 G 2,5 9,0 96,0 156,01705009 5 G 2,5 9,8 120,0 191,0
1705018 4 G 4 10,9 158,0 238,01705019 5 G 4 12,1 192,0 300,0
1705028 4 G 6 13,4 231,0 357,01705029 5 G 6 15,0 288,0 447,0
1705038 4 G 10 17,2 384,0 582,0.
art. n
Item no.
n. conduttori &sezione
dimensionn x mm²
diametromm
outer-Ømm
peso ramekg/km
Cu indexkg/km
peso nettokg/kmweightkg/km
1705048 4 G 16 21,7 614,0 925,01705049 5 G 16 24,3 768,0 1.167,0
1705058 4 G 25 25,4 960,0 1.382,0
1705067 4 G 35 31,0 1.344,0 1.960,0
1705076 4 G 50 36,6 1.920,0 2.773,0
cavi di collegamento motore flessibili per uso in catene portacavi con requisiti meccani-ci, dinamici ed elettrici estremi, idoneo per impiego in linee automatiche, impianti di pro-duzione, sistemi di sollevamento e trasporto. Idoneo per impiego in ambienti asciutti,umidi e all'aperto.
flexible power cable for highest mechanical and electrical requirements in drag chainapplications and moving drive systems in machine and plant engineering in the field ofcrane and conveyor technology in dry and humid rooms also outdoor.
• conforme a DESINA• approvato UL/CSA• privo di alogeni, ritardante la fiamma, bassa adesione• resistente all'azione di grassi, lubrificanti, liquidi refrigeranti• resistente agli oli secondo DIN EN 60811-2-1, 168 h a +100 °C• privo di silicone• resistente ai raggi UV
• conform to DESINA• UL/CSA approved• halogen-free, flame-retardant, low adhesion• resistant to oil, grease, coolant fluids and lubricants• resistant to oil acc. to DIN EN 60811-2-1, 168 h bei +100 °C• silicone-free• UV-resistant
• conforme a RoHS• conforme alla 2006/95/EC-("Direttiva Bassa Tensione") CE
• conform to RoHS• conform to 2006/95/EC-Guideline (CE marking)
materiale conduttore trefolo in rame rosso conductor material bare copper strandclasse conduttore fili sottili secondo DIN VDE 0295 cl. 6, IEC 60228 cl.6 conductor class super fine wires acc. to DIN VDE 0295 cl. 6 resp. IEC
60228 cl. 6isolamento conduttore TPE core insulation TPEdistinzione dei conduttori neri con numerazione bianca, 1x G/V 1.cond.: U / L1 / C
/ L+ *** 2.cond.: V / L2 3.cond.: W / L3 / D / L- *** 4.cond.: 4 / N
core identification BK with WH numerals, one core GNYE 1.core: U / L1 /C / L+ *** 2.core: V / L2 3.core: W / L3 / D / L- *** 4.core:4 / N
cordatura conduttori cordati attorno a elemento di rinforzo centrale stranding cores stranded in opt. lay length around tensile strengthcenter
materiale guaina esterna TPE outer sheath TPEcolore guaina nero ( RAL 9005) sheath colour black (RAL 9005)marcatura secondo standard TKD printing acc. to TKD printnorm
tensione nominale 600/1.000 V rated voltage 600/1.000 Vtensione di prova 4.000 V testing voltage 4.000 Valtre caratteristiche max. accelerazione 80 m/s²; velocità con catena auto-
portante 10 m/s; scorrevole fino a 6 m/s; max. lunghez-za catena autoportante/scorrevole 400 m
other characteristics max. acceleration 80 m/s²; speed self-supporting up to10 m/s, gliding up to 6 m/s; max. path length self-sup-porting/gliding to 400 m
raggio min. curv. p. fissa 4 x d min. bending radius fixed 4 x draggio min. curv. p. mobile 7,5 x d min. bending radius moved 7,5 x dtemp. eser. fissa min/max -40 °C / +90 °C operat. temp. fixed min/max -40 °C / +90 °Ctemp. eser. mobile min/max -35 °C / +90 °C operat. temp. moved min/max -35 °C / +90 °Ccomportamento al fuoco secondo IEC 60332-1, test della fiamma, FT1 burning behavior acc. to IEC 60332-1, cable flame test, FT1approvazioni UL 80 °C, 1.000 V, cULus 80 °C, 1.000 V approvals UL 80 °C, 1.000 V, cULus 80 °C, 1.000 V
.
art. n
Item no.
n. conduttori &sezione
dimensionn x mm²
diametromm
outer-Ømm
peso ramekg/km
Cu indexkg/km
peso nettokg/kmweightkg/km
1705203 4 G 1,5 7,6 58,0 97,0
1705213 4 G 2,5 9,0 96,0 151,01705214 5 G 2,5 9,8 120,0 187,0
1705224 4 G 4 10,9 158,0 232,01705225 5 G 4 12,1 192,0 295,0
1705234 4 G 6 13,4 231,0 348,01705235 5 G 6 15,0 288,0 436,0
1705245 4 G 10 17,2 384,0 570,01705246 5 G 10 19,3 480,0 721,0
.
art. n
Item no.
n. conduttori &sezione
dimensionn x mm²
diametromm
outer-Ømm
peso ramekg/km
Cu indexkg/km
peso nettokg/kmweightkg/km
1705256 4 G 16 21,7 614,0 905,01705257 5 G 16 24,3 768,0 1.140,0
1705267 4 G 25 25,4 960,0 1.355,0
1705277 4 G 35 31,0 1.344,0 1.914,0
1705287 4 G 50 36,6 1.920,0 2.715,0
1705297 4 G 70 38,8 2.688,0 3.450,0
cavi di collegamento motore schermati raccomandati per applicazioni EMC flessibili peruso in catene portacavi con requisiti meccanici, dinamici ed elettrici elevati, idoneo perimpiego in linee automatiche, impianti di produzione, sistemi di sollevamento e traspor-to. Idonei per uso in ambienti secchi,umidi e all'aperto.
flexible shielded power cable for EMC-compatible at high electrical andmechanical requirements in drag chain and motion drive systems in machine and plantengineering in the field of crane and conveyor technology in dry and humid rooms alsooutdoor.
• approvato UL/CSA• ritardante la fiamma• resistente agli oli secondo DIN EN 50363-4-1, cl 2• privo di silicone• resistente ai raggi UV
• UL/CSA approved• flame-retardant• resistant to oil acc. to DIN EN 50363-4-1, cl. 2• silicone-free• UV-resistant
• conforme a RoHS• conforme alla 2006/95/EC-("Direttiva Bassa Tensione") CE
• conform to RoHS• conform to 2006/95/EC-Guideline (CE marking)
materiale conduttore trefolo in rame rosso conductor material bare copper strandclasse conduttore fili sottili secondo DIN VDE 0295 cl. 6, IEC 60228 cl.6 conductor class super fine wires acc. to DIN VDE 0295 cl. 6 resp. IEC
60228 cl. 6isolamento conduttore PELON® core insulation PELON®distinzione dei conduttori neri con numerazione bianca, 1x G/V 1.cond.: U / L1 / C
/ L+ *** 2.cond.: V / L2 3.cond.: nero W / L3 / D / L- *** 4.cond.: 4 / N
core identification BK with WH numerals, one core GNYE 1.core: U / L1 /C / L+ *** 2.core: V / L2 3.core: W / L3 / D / L- *** 4.core:4 / N
cordatura conduttori cordati attorno a elemento di rinforzo centrale stranding cores stranded in opt. lay length around tensile strengthcenter
PVC inner sheath material PVCcalza in rame stagnato con copertura min.85% shield copper braid tinned, opt. coverage appr. 85%PVC, bassa aderenza outer sheath PVC, low adhesionnero, RAL 9005 sheath colour black, RAL 9005
materiale guaina interna
materiale guaina esternacolore guainamarcatura secondo standard TKD printing acc. to TKD printnorm
tensione nominale 600/1.000 V rated voltage 600/1.000 Vtensione di prova 4.000 V testing voltage 4.000 Valtre caratteristiche max. accelerazione 80 m/s²; velocità con catena auto-
portante 10 m/s; scorrevole fino a 5 m/s; max. lunghez-za catena autoportante/scorrevole 100 m
other characteristics max. acceleration 80 m/s²; speed self-supporting up to10 m/s, gliding up to 5 m/s; max. path length self-sup-porting/gliding to 100 m
raggio min. curv. p. fissa 4 x d min. bending radius fixed 4 x draggio min. curv. p. mobile 7,5 x d min. bending radius moved 7,5 x dtemp. eser. fissa min/max -20 °C / +70 °C operat. temp. fixed min/max -20 °C / +70 °Ctemp. eser. mobile min/max -5 °C / +70 °C operat. temp. moved min/max -5 °C / +70 °Ccomportamento al fuoco secondo IEC 60332-1, test della fiamma, FT1 burning behavior acc. to IEC 60332-1, cable flame test, FT1approvazioni UL 80°C, 1.000 V, cULus 80°C, 1.000 V approvals UL 80°C, 1.000 V, cULus 80°C, 1.000 V
.
art. n
Item no.
n. conduttori &sezione
dimensionn x mm²
diametromm
outer-Ømm
peso ramekg/km
Cu indexkg/km
peso nettokg/kmweightkg/km
1705503 4 G 1,5 9,8 86,0 153,0
1705514 4 G 2,5 11,2 132,0 220,01705515 5 G 2,5 12,4 150,0 271,0
1705525 4 G 4 13,7 212,0 345,01705526 5 G 4 14,9 260,0 415,0
1705536 4 G 6 16,2 305,0 490,01705537 5 G 6 17,8 378,0 605,0
1705547 4 G 10 20,6 513,0 790,01705548 5 G 10 22,5 660,0 990,0
.
art. n
Item no.
n. conduttori &sezione
dimensionn x mm²
diametromm
outer-Ømm
peso ramekg/km
Cu indexkg/km
peso nettokg/kmweightkg/km
1705558 4 G 16 25,3 805,0 1.240,01705559 5 G 16 27,9 990,0 1.495,0
1705569 4 G 25 28,8 1.210,0 1.740,0
1705579 4 G 35 34,6 1.650,0 2.410,0
1705589 4 G 50 40,4 2.300,0 3.350,0
1705599 4 G 70 48,5 2.950,0 4.380,0
cavi di collegamento motore schermati raccomandati per applicazioni EMC flessibili peruso in catene portacavi con requisiti meccanici, dinamici ed elettrici estremi, idoneo perimpiego in linee automatiche, impianti di produzione, sistemi di sollevamento e traspor-to. Idonei per uso in ambienti secchi,umidi e all'aperto.
flexible shielded power cable for EMC-compatible at highest electrical andmechanical requirements in drag chain and motion drive systems in machine and plantengineering in the field of crane and conveyor technology in dry and humid rooms alsooutdoor.
• approvato UL/CSA• ritardante la fiamma, bassa adesione, resistente all'idrolisi e ai
microbi• resistente all'azione di grassi, lubrificanti, liquidi refrigeranti• resistente agli oli secondo DIN EN 60811-2-1, 168 h a +100 °C• privo di silicone• resistente ai raggi UV•
• UL/CSA approved• flame-retardant, low abrasion, resistant to hydrolysis and microbe• resistant to oil, grease, coolant fluids and lubricants• resistant to oil acc. to DIN EN 60811-2-1, 168 h bei +100 °C• silicone-free• UV-resistant• NEW: with Ripcord, for faster and core protected dismantling
• conforme a RoHS• conforme alla 2006/95/EC-("Direttiva Bassa Tensione") CE•
• conform to RoHS• conform to 2006/95/EC-Guideline (CE marking)• NEW: with reduced outer diameters, for lower weight, smaler design and lower ben-
ding radii; up from production date March 2016 (old value)
materiale conduttore trefolo in rame rosso conductor material bare copper strandclasse conduttore fili sottili secondo DIN VDE 0295 cl. 6, IEC 60228 cl.6 conductor class super fine wires acc. to DIN VDE 0295 cl. 6 resp. IEC
60228 cl. 6isolamento conduttore TPE core insulation TPEdistinzione dei conduttori neri con numerazione bianca, 1x G/V 1.cond.: U / L1 / C
/ L+ *** 2.cond.: V / L2 3.cond.: W / L3 / D / L- *** 4.cond.: 4 / N
core identification BK with WH numerals, one core GNYE 1.core: U / L1 /C / L+ *** 2.core: V / L2 3.core: W / L3 / D / L- *** 4.core:4 / N
cordatura conduttori cordati attorno a elemento di rinforzo centrale stranding cores stranded in opt. lay length around tensile strengthcenter
TPE inner sheath material TPE, with Rip cordcalza in rame stagnato con copertura min.85% shield copper braid tinned, opt. coverage appr. 85 %TPE outer sheath TPEnero, RAL 9005 sheath colour black, RAL 9005
materiale guaina interna
materiale guaina esternacolore guainamarcatura secondo standard TKD printing acc. to TKD printnorm
tensione nominale 600/1.000 V rated voltage 600/1.000 Vtensione di prova 4.000 V testing voltage 4.000 Valtre caratteristiche max. accelerazione 80 m/s²; velocità con catena auto-
portante 10 m/s; scorrevole fino a 6 m/s; max. lunghez-za catena autoportante/scorrevole 400 m
other characteristics max. acceleration 80 m/s²; speed self-supporting up to10 m/s, gliding up to 6 m/s; max. path length self-sup-porting/gliding to 400 m
raggio min. curv. p. fissa 4 x d min. bending radius fixed 4 x draggio min. curv. p. mobile 7,5 x d min. bending radius moved 7,5 x dtemp. eser. fissa min/max -40 °C / +90 °C operat. temp. fixed min/max -40 °C / +90 °Ctemp. eser. mobile min/max -35 °C / +90 °C operat. temp. moved min/max -35 °C / +90 °Ccomportamento al fuoco secondo IEC 60332-1, test della fiamma, FT1 burning behavior acc. to IEC 60332-1, cable flame test, FT1approvazioni UL 80°C, 1.000 V, cULus 80°C, 1.000 V approvals UL 80°C, 1000 V, cURus 80°C, 1000 V
.
art. n
Item no.
n. conduttori &sezione
dimensionn x mm²
diametromm
outer-Ømm
peso ramekg/km
Cu indexkg/km
peso nettokg/kmweightkg/km
1705823 4 G 1,5 9,8 86,0 148,0
1705833 4 G 2,5 11,2 132,0 210,01705834 5 G 2,5 12,4 150,0 260,0
1705843 4 G 4 13,7 212,0 325,01705844 5 G 4 14,9 260,0 395,0
1705853 4 G 6 16,2 305,0 461,01705854 5 G 6 17,8 378,0 561,0
1705863 4 G 10 20,6 513,0 760,01705864 5 G 10 22,5 660,0 920,0
.
art. n
Item no.
n. conduttori &sezione
dimensionn x mm²
diametromm
outer-Ømm
peso ramekg/km
Cu indexkg/km
peso nettokg/kmweightkg/km
1705873 4 G 16 22,5 (25,3) 805,0 985,01705874 5 G 16 27,9 990,0 1.405,0
1705883 4 G 25 28,8 1.210,0 1.616,0
1705892 4 G 35 34,6 1.650,0 2.290,0
1705901 4 G 50 40,4 2.300,0 3.240,0