v080813 1. AR-737H/U1356 INTODUCTION 2. PIN DEFINE 1.2 MIFARE 2.1 Wiring of AR-737H/U (Version I ) 2.1 Wiring of AR-737H/U (Version II & afterward) 2.3 Adding for Version III & afterward 1.3 Function Support 1.1 Contents 1.4 Specification 1.5 Difference in Versions 1.6 Wiegand Format Setting Mifare is the most widely applied contactless smart card technology developed by PHILIPS with ISO standard. AR-737H/U 1356 adopts PHILIPS high-security proven standard and meets the high performance.(On the mode of 737 platform) Its MIFARE chip equip the read & write function to ensure auxiliary WG reader (AR-737U 1356) or networking reader (AR-737H 1356) . 6-PIN Jumper select “OUTPUT” II Mode Version AR-737H AR-737U JP3 Open JP3 Close JP3 Open JP3 Close I III IV 6-PIN Jumper select “WG” 6-PIN Jumper select “OUTPUT” 6-PIN Jumper select “WG” Note: 1.Version IV & afterward could be adjusted to H or U by dip-switch and 6-pin jumper 2.Version I-III have to be changed by hardware modification. The version III adds a 6-pin jumper for door&alarm relay driver and WG switching. Its setting should follow the rule below: WG OUTPUT WG OUTPUT AR-737H Function PIN Relay triger Orange/Gray AR-737U Function Wiegand Green/Blue PIN Data 0 Data 1 1 ON 2 3 4 5 1 ON 2 3 4 1 ON 2 3 4 5 1 ON 2 3 4 WD1 ALARM DOOR ALARM DOOR WD0 WD1 WD0 Output format WG34 WG26 ABA10 Serial ASCII J1 (DIP_SW1) Open (OFF) Close (ON) Open (OFF) Close (ON) J2 (DIP_SW2) Open (OFF) Open (OFF) Close (ON) Close (ON) DIP_SW DIP_SW DIP_SW DIP_SW DIP_SW DIP_SW

Upload: hoangnga

Post on 30-Mar-2018

220 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: 737HU1356EN-080813 - SOYAL EN.pdf · meets the high performance.(On the mode of 737 platform) Its MIFARE chip equip the read & write function to ensure auxiliary WG reader (AR-737U

v080813

1. AR-737H/U1356 INTODUCTION

2. PIN DEFINE1.2 MIFARE

2.1 Wiring of AR-737H/U (Version I )

2.1 Wiring of AR-737H/U (Version II & afterward)

2.3 Adding for Version III & afterward

1.3 Function Support

1.1 Contents

1.4 Specification

1.5 Difference in Versions

1.6 Wiegand Format Setting

Mifare is the most widely applied contactless smart card technology developed by PHILIPS with ISO standard.

AR-737H/U 1356 adopts PHILIPS high-security proven standard and meets the high performance.(On the mode of 737 platform) Its MIFARE chip equip the read & write function to ensure auxiliary WG reader(AR-737U 1356) or networking reader (AR-737H 1356) .

6-PIN Jumper select “OUTPUT”II

Mode

VersionAR-737HAR-737U

JP3 Open JP3 Close

JP3 Open JP3 Close

I

III

IV

6-PIN Jumper select “WG”

6-PIN Jumper select “OUTPUT”6-PIN Jumper select “WG”

Note: 1.Version IV & afterward could be adjusted to H or U by dip-switch and 6-pin jumper 2.Version I-III have to be changed by hardware modification.

The version III adds a 6-pin jumper for door&alarm relay driver and WG switching. Its setting should follow the rule below:

WG OUTPUTWG OUTPUT

AR-737H

Function

PIN

Relay triger

Orange/Gray

AR-737U

Function Wiegand

Green/BluePIN

Data 0Data 1

1

ON

2 3 4 5

1

ON

2 3 4

1

ON

2 3 4 5

1

ON

2 3 4

WD1 ALARMDOOR

ALARMDOORWD0

WD1WD0

Output format

WG34

WG26

ABA10

Serial ASCII

J1 (DIP_SW1)

Open (OFF)

Close (ON)

Open (OFF)

Close (ON)

J2 (DIP_SW2)

Open (OFF)

Open (OFF)

Close (ON)

Close (ON)

DIP_SW

DIP_SW

DIP_SWDIP_SW

DIP_SW

DIP_SW

Page 2: 737HU1356EN-080813 - SOYAL EN.pdf · meets the high performance.(On the mode of 737 platform) Its MIFARE chip equip the read & write function to ensure auxiliary WG reader (AR-737U

3.1.1 AR-737H1356 connection to PC

1

3.1.2 Software setting from Soyal device tools

2

3

4

5

6

Select communication port. Enter the target AR-737H’s Node ID (To ignore Node ID , enter 255)

Enable or disable the functions of AR-737H. Click “write” to download new setting to device.

Click ”Read” to upload parameters from device to Node737 application. The screen will show current device parameter and its version, and then key-in the Node ID you want to change.

6

4

5

2

1

3 Read Write Exit

3. INSTALLATION DIAGRAM

3.2 AR-737U connect to AR-721H

AR-721H

3.4 AR-737H connect to EM lock & Exit Button with Relay board

3.3 AR-737U connect to AR-829E, AR-727H

AR-737H

RS-485 A+

RS-485 B-

Exit Button

4. APENDIX

Be sure to record the user number, the user name, the card ID number (card code)and the user code. It’s import to keep this information in a secure place. A block user log form has been included for purpose. Do not write on this form; the form is as a photocopy master.

User No. User Code User Name Site code : Card code

v080813

Page 3: 737HU1356EN-080813 - SOYAL EN.pdf · meets the high performance.(On the mode of 737 platform) Its MIFARE chip equip the read & write function to ensure auxiliary WG reader (AR-737U

123456

ModeUnit

737U125(WG)

Version IVDIP_SW6.7.8

737H125(RS-485)

1.6 Indicator Displaying Way While Card Flashin

1. AR-737H/U 125 INTRODUCTION

1.3 Difference in Versions

AR-737HAR-737UMode

Version

JP2 Open

JP2 Open4-PIN Jumper select“WG”

JP2 Close

6-PIN Jumper select “OUTPUT”

JP2 Close4-PIN Jumper select “OUTPUT”

I

II

III

IV

V

The AR-737H/U125 is a proximity reader which allows performing as an auxiliary WG reader(AR-737U 125) or networking reader(AR-737H 125)

1.1 Contents

1.2 Specification

JP2

Jumper

667 7

JumperJP2

JumperJumperJP2

6-PIN Jumper select “WG”

8-PIN Jumper select “OUTPUT”8-PIN Jumper select “WG”

Version I Version II Version III Version IV Version V

1.7 Adding for Version II & III & IVThe version ll , lll & IV add a 6-pin jumper for wiegand signal or relay output selection. Its setting should follow the rules as below:

FrequencyPower RequirementPower Consumption

Baud RateEnvironmentIndicatorRead / WriteProximity Reading RangeSupported TagsWaterproofColorDimension(mm)Weight(g)Housing Material

Communication Interface

125KHz9-24 VDC<1.5WRS-485(737H only),Wiegand(737U only)and OMRON9600 bps / 19200 bps(N,8,1)-20 C~+75 CA bi-color LED and a beeperRead only12-20cmEM4001/EM4012 compliantYes(Option)Dark Gray113(L)x71(W)x36(H)80ABS

o o

1234

JP2 Open5-PIN Jumper select“WG”

12345

JP2 Close5-PIN Jumper select “OUTPUT”

12345

1234

123456

123456

12345678

78

WG OUTPUTWG OUTPUT

AR-737U

Function Wiegand

Green/BluePINAR-737H

Function

PIN

Relay triger

Green/Blue

SOYAL warrants that the product(s)shall be free from manufacturing defects in materials and workmanship for a period of fifteen(15) months from the date of delivery provided that the product was properly installed and used.

on the PCB board ,

because it is SOYAL warranty.

Please visit WWW.SOYAL.COM to download the Soyal software, Manual, Catalog & User guide

Data 0Data 1

0506-123456AR-737HXXXXXXNote: Do not tear a paster that

1.4 Mode Setting

1.5 Wiegand Format Setting

JP2VersionI,II,III

Open(Off)

Close(On)

Version IVDIP_SW6

Open(Off)

Close(On) J7.Open(Off)J8.Open(Off)

J6.Close(On)

J6.Open(Off)J7.Close(On)J8.Close(On)

3. INSTALLATION DIAGRAM

3.1.1 AR-737H125 connection to PC

PIN DEFINE

2.1 Wiring of AR-737H/U 125 (Version I)

2.2 Wiring of AR-737H/U 125 (Version II& III & IV)PIN DEFINE

v080821

1

2

3

4

5

6

Select communication port.

Enter the target AR-737H’s Node ID (To ignore Node ID , enter 255)

Enable or disable the functions of AR-737H.

Click “write” to download new setting to device.

Click ”Read” to upload parameters from device to Node737 application.

The screen will show current device parameter and its version, and then key-in the Node ID you want to change.

3.2 AR-737U connect to AR-721H

AR-721H

3.4 AR-737H connect to EM lock & Exit Button with Relay board

3.3 AR-737U connect to AR-829E, AR-727H

AR-737H

RS-485 A+

RS-485 B-

Exit Button

3.1.2 Software setting from Soyal device tools

6

4

5

2

1

3 Read Write Exit

Page 4: 737HU1356EN-080813 - SOYAL EN.pdf · meets the high performance.(On the mode of 737 platform) Its MIFARE chip equip the read & write function to ensure auxiliary WG reader (AR-737U

123456

ModeUnit

737U125(WG)

Version IVDIP_SW6.7.8

737H125(RS-485)

1.6 Indicator Displaying Way While Card Flashin

1. AR-737H/U 125 INTRODUCTION

1.3 Difference in Versions

AR-737HAR-737UMode

Version

JP2 Open

JP2 Open4-PIN Jumper select“WG”

JP2 Close

6-PIN Jumper select “OUTPUT”

JP2 Close4-PIN Jumper select “OUTPUT”

I

II

III

IV

V

The AR-737H/U125 is a proximity reader which allows performing as an auxiliary WG reader(AR-737U 125) or networking reader(AR-737H 125)

1.1 Contents

1.2 Specification

JP2

Jumper

667 7

JumperJP2

JumperJumperJP2

6-PIN Jumper select “WG”

8-PIN Jumper select “OUTPUT”8-PIN Jumper select “WG”

Version I Version II Version III Version IV Version V

1.7 Adding for Version II & III & IVThe version ll , lll & IV add a 6-pin jumper for wiegand signal or relay output selection. Its setting should follow the rules as below:

FrequencyPower RequirementPower Consumption

Baud RateEnvironmentIndicatorRead / WriteProximity Reading RangeSupported TagsWaterproofColorDimension(mm)Weight(g)Housing Material

Communication Interface

125KHz9-24 VDC<1.5WRS-485(737H only),Wiegand(737U only)and OMRON9600 bps / 19200 bps(N,8,1)-20 C~+75 CA bi-color LED and a beeperRead only12-20cmEM4001/EM4012 compliantYes(Option)Dark Gray113(L)x71(W)x36(H)80ABS

o o

1234

JP2 Open5-PIN Jumper select“WG”

12345

JP2 Close5-PIN Jumper select “OUTPUT”

12345

1234

123456

123456

12345678

78

WG OUTPUTWG OUTPUT

AR-737U

Function Wiegand

Green/BluePINAR-737H

Function

PIN

Relay triger

Green/Blue

SOYAL warrants that the product(s)shall be free from manufacturing defects in materials and workmanship for a period of fifteen(15) months from the date of delivery provided that the product was properly installed and used.

on the PCB board ,

because it is SOYAL warranty.

Please visit WWW.SOYAL.COM to download the Soyal software, Manual, Catalog & User guide

Data 0Data 1

0506-123456AR-737HXXXXXXNote: Do not tear a paster that

1.4 Mode Setting

1.5 Wiegand Format Setting

JP2VersionI,II,III

Open(Off)

Close(On)

Version IVDIP_SW6

Open(Off)

Close(On) J7.Open(Off)J8.Open(Off)

J6.Close(On)

J6.Open(Off)J7.Close(On)J8.Close(On)

3. INSTALLATION DIAGRAM

3.1.1 AR-737H125 connection to PC

PIN DEFINE

2.1 Wiring of AR-737H/U 125 (Version I)

2.2 Wiring of AR-737H/U 125 (Version II& III & IV)PIN DEFINE

v080821

1

2

3

4

5

6

Select communication port.

Enter the target AR-737H’s Node ID (To ignore Node ID , enter 255)

Enable or disable the functions of AR-737H.

Click “write” to download new setting to device.

Click ”Read” to upload parameters from device to Node737 application.

The screen will show current device parameter and its version, and then key-in the Node ID you want to change.

3.2 AR-737U connect to AR-721H

AR-721H

3.4 AR-737H connect to EM lock & Exit Button with Relay board

3.3 AR-737U connect to AR-829E, AR-727H

AR-737H

RS-485 A+

RS-485 B-

Exit Button

3.1.2 Software setting from Soyal device tools

6

4

5

2

1

3 Read Write Exit