MSA EUROPE 2005
AirElite 4h
The unique Closed Circuit Breathing Apparatus
4 hours rated service time
Air regeneration with KO2
Innovative Hi-Tech
MSA EUROPE 2005
AirElite 4h
Design:2 KO2-canisters
with automatic starters
and service free cooling
Exhalation bag
Inhalation bag
Surplus valve
Blower assisted exhalation
Battery
IC-Air control monitor
Charging jack
MSA EUROPE 2005
AirElite 4h
Design:
Electronic terminal block
Mask connector, automatic start, air hoses Consumption sensor
Air flow routing and convection cooler
Air distributor
Particle filter
MSA EUROPE 2005
AirElite 4h
Circuit:
Exhalation
Inhalation
The exhalation air is enriched with oxygen
CO2 and H2O are absorbed
MSA EUROPE 2005
AirElite 4h
KO2 - function and reaction:
2KO2 + CO2 + H2O >> [K2CO3*H2O] + 1.5 O2 + E(Potassium Hyperoxide) (Potassium Carbonate) (Heat) KO2 is a very reactive, extremely stable chemical, reacting with the humidity and the CO2 of the exhalation air, releasing O2 and heat (exothermic reaction)
KO2 oxidises reliably all foreign substances
... and the breathing air is very dry!
MSA EUROPE 2005
AirElite 4h
KO2 - reaction:
2KO2 + CO2 + H2O >> [K2CO3*H2O] + 1.5 O2 + E: Increased exhalation = more CO2 + more H2O raise the oxygen generation! Or vice versa, less consumption reduces the O2-generation. At any time, more O2 is generated than used!
MSA EUROPE 2005
AirElite 4h
Flexible Service Time:The service time depends on the respiration perform- ance. High performance (heavy work) increases the oxygen generation, low performance (light work) extends the service time!
Sudden changes to high performance are compen-sated by the oxygen surplus!
0
120
240
360
480
600
720
10 20 30 40 50 60Tim
e (
min
ute
s)
Respiration (Litres/minute)
Service Time : Consumption
End of rated service time
0
120
240
360
480
600
720
10 20 30 40 50 6010 20 30 40 50 60
Comparison: SCBA with 2 x 6,8 l/300 bar cylinders = AirElite 4h = SCBA
Tim
e (
min
ute
s)
Respiration (Litres/minute)
MSA EUROPE 2005
AirElite 4h
7,200 Litres Breathing Air for 4 hours at 30 litres / minute consumption
DIN 58652 - Respiratory Protective Devices - Self Contained Closed Circuit B. A. - Part 2: Chemical Oxygen (KO2) Generating Type for work and rescue
and
vfdb 0802 (Regulations for the selection and use of Respiratory Protection Devices and Chemical Protection Suits for the Fire Brigades) including appendix D (Flame engulfment)
MSA EUROPE 2005
AirElite 4h
The breathing air regeneration
Advantage:
O2-generation / CO2-absorption are effected exclusively by KO2:
in one stage, compressed oxygen and CO2 absorbers (soda lime), that must match each other, are not needed.
MSA EUROPE 2005
AirElite 4h
KO2 - B. A. do not need:
oxygen cylinders
oxygen pumps
deep freezers for ice production
MSA EUROPE 2005
AirElite 4h
KO2 offers:
optimal O2-surplus there is no compressed-O2-reserve, which may cause a CO2-intoxication if the soda lime cartridge is exhausted prematurely [CO2 -enrichment in the closed circuit]
a CO2 intoxication is impossible!
MSA EUROPE 2005
AirElite 4h
KO2 is:
totally breath controlled (no valves and pressure reducers that need maintenance)
simple in construction, has very safe function, and is very quickly ready for use.
almost maintenance free
long storable
MSA EUROPE 2005
AirElite 4h
What is happening in the KO2-canisters?
CO2-absorption
water absorption
O2-generation
chemical transformation of KO2
generation of heat air cooled heat exchangers + maintenance free water cooling
MSA EUROPE 2005
AirElite 4h
Dimensions
and weight:
360 mm
600
mm
190 mm
15 kg
MSA EUROPE 2005
AirElite 4h
Simple donning anddoffing, also during use (breathing hoses under left arm)
MSA EUROPE 2005
AirElite 4h
Low cost training
TR-conversion kit for quick conversion of the operational AirElite into a trainer
MSA EUROPE 2005
AirElite 4h
dependent of the ambient air,
the P3 particle filter permits training in dense fog and nontoxic smoke
Trainer
MSA EUROPE 2005
AirElite 4h
and the IC-Air
manages and monitors the AirElite
clears the AirElite for the mission
warns of defects
counts the consumption
signals audibly and visually
alarms at immobility
offers a manual alarm
MSA EUROPE 2005
AirElite 4h
and the IC-Air
Test button and display illumination
LED red/greenManual immobility alarm
Reset and calibration
Automatic immobility alarm > 95 dBa
MSA EUROPE 2005
AirElite 4h
IC-Air display at start :
Function check: display segments + + beep + light = OK
Failures: 1 = battery
2 = starter / canister
3 = blower
8 = sensor Beep
1
MSA EUROPE 2005
AirElite 4h
IC-Air display in use:
Capacity indication: 100 % to 0 %
Cylinder symbol : 8 segments
50 % residual capacity: short beep 15 sec
20 % residual capacity: LED red/green, interval beep, escape symbol
5 % residual capacity: LED flashing red, continuous beep, escape symbol flashing
0 % residual capacity: AirElite continues operation
MSA EUROPE 2005
AirElite 4h
Donning:
MSA EUROPE 2005
AirElite 4h
Inspection & Maintenance6 months: visual check (lead seals)
recharge battery
check readiness (test button)
(if fitted) 2 years: replace KO2-canisters training
5 years: replace battery consume originally packed KO2-canisters
MSA EUROPE 2005
AirElite 4h
Cleaning & Disinfection Mask Breathing tubes Breathing bag and valve control Air distributor Blower (spray disinfection only)
MSA EUROPE 2005
AirElite 4h
MSA EUROPE 2005
AirElite 4h
Application
Mining: Mine Rescue Teams
The BA on site with the lowest maintenance requirements, the least periphery logistics,the fastest readiness, the most cost efficient training.
The BA for quick missions!
MSA EUROPE 2005
AirElite 4h
Application
Fire Brigade:
The BA for the rare long-run missions!For stand-by rescue teams(2 AirElite for fire engines)Fire Brigades with tunnel missions(Railways/Subways/Road tunnels)Chemical industries, Refineries, Tank farms.Military facilities, Bunkers, Depots.Port authorities: onboard fire fighting
Free from frequent service & maintenance!
MSA EUROPE 2005
AirElite 4h
USPs in a nutshell: excellent breathing comfort: low resistances
low air temperature
dry breathing air maintenance and ice free cooling
no periphery logistics (cylinders, pumps, ice) low cost training
slim design, breathing hoses under the arm
top related